Establishment Of Cfc In Brass And Bell Metal Utensils Cluster, Kashipur, Purulia.
Tender Value
2.39 Crore
Estimated cost
Bid Submission
01 Nov 2022
0 days left
EMD
4.79 Lakhs
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
kashipur → West Bengal
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Establishment Of Cfc In Brass And Bell Metal Utensils Cluster, Kashipur, Purulia.
BOQ
| Sl. No. | Item Description |
| 1 | Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed. |
| 2 | Earth work in excavation of foundation trenches or drains, in all sorts of soil (including mixed soil but excluding laterite or sandstone) including removing, spreading or stacking the spoils within a lead of 75 m. as directed. The item includes necessary trimming the sides of trenches, levelling, dressing and ramming the bottom, bailing out water as required complete.(a) Depth of excavation not exceeding 1,500 mm. |
| 3 | b) Depth of excavation for additional depth beyond 1,500 mm. and upto 3,000 mm. but not requiring shoring. |
| 4 | d) Add extra for excavation in morum soil |
| 5 | Box cutting or filling in Road embankment in all sorts of soil including spreading the spoils properly over the flank as necessary or on berm to approximate grade & camber and rolling the sub-grade with power roller to proper camber and grade as per direction and satisfaction of Engineer-in-charge including uprooting and removing plants and jungles when and where necessary.(a) Depth up to 150 mm. |
| 6 | (b) for additional Depth of 150mm and apart |
| 7 | Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(a) With earth obtained from excavation of foundation |
| 8 | (A) Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) |
| 9 | Pre-Constructional Anti-termite measures:(c) Anti termite treatment to the top surface of the consolidated earth within plinth walls with chemical emulsion by admixing chloropyrofos emulsifiable ncentrates (1% concentration) with water by weight at the rate of 5 Litres per sq. m. of the surface before sand bed or sub-grade is laid. Holes upto 50 mm. to 75 mm. deep at 150 mm. centre to centre both ways shall be made with 12 mm, diameter mild steel rod on the surface to facilitate saturation of the soil with the chemical emulsion. The work shall be carried out as per specification described in para 6.4 of code IS-6313 (part -II) 1981. ( Mode of measurment will be per Sq.m of plan area of plinth treated.) |
| 10 | Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. |
| 11 | Granular Sub-base with Graded Material (Table:- 400-1)B. By Mix in Place Method :Construction of granular sub-base by providing graded material, mixing by mix in place method with Rotavator at OMC, spreading in uniform layers with Motor grader on prepared surface in proper grade and camber,compacting with vibratory roller to achieve the desired density, including lighting, guarding, barricading, including cost of all materials, machinery, tools and plants including cost of quality control complete as per Clause 401 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). (iv) Grading – IVInternal Road |
| 12 | Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches. |
| 13 | (I) Cement concrete with graded stone ballast (40 mm size excluding shuttering) In ground floor (A) [Pakur Variety](a) 1:3:6 proportion |
| 14 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation.[using concrete mixture]M 20 Grade InGroundfloor |
| 15 | Controlled Cement concrete with well graded stone chips (20 mm nominal size) excluding shuttering and reinforcement with complete design of concrete as per IS : 456 and relevant special publications, submission of job mix formula after preliminary mix design after testing of concrete cubes as per direction of Engineer-in charge. Consumption of cement will not be less than 300 Kg of cement with Super plasticiser per cubic meter of controlled concrete but actual consumption will be determined on the basis of preliminary test and job mix foumula. In ground floor and foundation. [using concrete mixture](b) M 25 GradeIn Ground floor |
| 16 | In first floor |
| 17 | In Second floor |
| 18 | Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor)(f) 25 mm to 30 mm shuttering without staging in foundation |
| 19 | (c) Steel shuttering or 9 to 12 mm thick approved quality ply board shuttering in any concrete workIn Ground floor |
| 20 | In First floor |
| 21 | In Second floor |
| 22 | (e) Extra for staging beyond 4 m in any floor (Mode ofmeasurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m) |
| 23 | Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction.(i) Tor steel/Mild SteelII. JSW/JSPL/SHYAM/SRMB/BMASL/ELECROSTEEL/SSLIn Ground floor |
| 24 | In First floor |
| 25 | In Second floor |
| 26 | Brick work with 1st class bricks in cement mortar (1:6)(a) In foundation and plinth |
| 27 | 125 mm. thick brick work with 1st class bricks in cement mortar (1:3) in ground floor. |
| 28 | 250 mm thick Brick work with Fly Ash Bricks (250mmx125mmx75mm) as per IS 12894:2002 in cement mortar (1:6)b) In Super structure ,Ground Floor |
| 29 | In First floor |
| 30 | In Second floor |
| 31 | (a) 125 mm. thick Flyash brick work as per IS 12894:2002 in cement mortar (1:4) in ground floor. In Ground floor |
| 32 | In First floor |
| 33 | Labour for Chipping of concrete surface before taking upPlastering work. |
| 34 | 25mm. thick damp proof course with cement concrete with stone chips (1:1.5:3) [with graded stone aggregate 10 mm nominal size] and admixture of water proofing compound as per manufacturer\"s specification followed by two coat of polymer based paint, (1st coat after 4 to 5 days of concrete laying and 2 nd coat just before brick masonry work) as directed (cost of water proofing compound & polymer based paint to be paid separately).( Chequering not required over concrete or painted surface).[Note: - Waterproofing as per item NO 9, polymer based paint as per item 8 (a) of Sub head C of section (C).. |
| 35 | Artificial stone in floor, dado, staircase etc with cement concrete (1:2:4) with stone chips, laid in panels as directed with topping made with ordinary or white cement (as necessary)and marble dust in proportion (1:2) including smooth finishing and rounding off corners including raking out joints or roughening of concrete surface andapplication of cement slurry before flooring works using cement @ 1.75 kg/sq.m all complete including all materials and labour. 3 mm. thick topping (High polishing grinding on this item is not permitted with ordinary cement).Using grey cement (ii)25 mm. thick>>In ground floor. |
| 36 | c) 60 mm thick interlocking designer concrete paver block M-35 grade for light-traffic zone,commercial & officecomplex,tourist resort as per IS: 15658-2006 (over 20-40 mmmedium sand bed on 250mm thk WBM/ WMM base course &250 mm thk bound gnaular /granular sub-base courseincluding cost of sand for sand bed but excluding cost of base,sub-base course & subgrade preparation.)Colour Density(ii) Coloured Decorative |
| 37 | Supplying , Spreading and consolidating moorum to a depth og 75mm at desired density and CBR as per specification with power roller to proper gradient and camber including watering as necessary, and lighting, guarding, barricading and making adequate earthened bundh where necessary to protect edges and curing with water for 2-3 days,mending cracks by rolling when necessary including all incidental charges of roller , cost of fuel and lubricants etc. complete as per specification. |
| 38 | Supplying and laying true to line and level vitrified tiles of approved brand (size not less than 600 mm X 600 mm X 10 mm thick) in floor, skirting etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry back side of tiles using cement @ 2.91Kg./sqM or using polymerised adhesive (6 mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per sqM below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles / epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contrr]e)(I) With application slurry @1.75 kg/ Sq.m, 20 mm sand cement mortar (1:4) & 2 mm thick cement slurry at back side of tiles, 0.2 kg/ Sq.m white cement for joint filling with pigment.In Ground floor. |
| 39 | In Firstfloor |
| 40 | Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc.(B) WallWith Sand Cement Mortar (1:3) 15 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m.(b) Area of each tile above 0.09 Sq.m(i) Coloured decorativeIn Ground Floor Wall |
| 41 | In Firstfloor Wall |
| 42 | Supplying and laying true to line and level Anti-Skid, Full Body, Homogeneous & Granular finish Vitrified Tiles conforming to IS:15622-2006 & IS 4457-2007 and testing shall be made in accordance with IS:13630 [Non- modular sizes for tiles with Skid resistance > 0.5, Mohr\"s hardness > 5.0, Staining resistance: Class-1, Water Absorption: E < 0.5%], MOR > 35 N/sq.mm in Internal area of building e.g. Toilet Block, Passage, Corridor, Accessible Open Terrace etc. set in 20 mm sand cement mortar (1:4) and 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg./Sqm or using Polymerised Adhesive (6 mm thick layer applied directly over finished artificial stone floor/ Mosaic etc without any backing course) laid after application slurry using 1.75 Kg of cement per Sqm below mortar only, joints grouted with admixture of white cement and colouring pigment to match with colour of tiles/ epoxy grout materials of approved make as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials, labour and all other incidental charges complete true to the manufacturer\"s specification and direction of Engineer-in-Charge. (White cement, synthetic adhesive and grout material to be supplied by the contractor).b) In Ground Floor: Sizes-600 mm x600mm x10 mm with breaking strength > 1500 NIn Ground floor. |
| 43 | In Firstfloor |
| 44 | 18 mm. to 22 mm. thick, kota stone slab set in 20 mm thick (avg) cement mortar (1:4)in floor, stair & lobby including pointing in cement slurry with admixture of pigment matching the stone shade, including grinding & polishing as per direction of Engineer - in - charge to match with the existing work. [Slurry for bedding @ 4.4 kg/Sq.m and pointing @2.0 kg/Sq.m]In Ground floor. |
| 45 | In Firstfloor |
| 46 | In Secondfloor |
| 47 | Supplying, fitting and fixing 18 mm. to 22 mm. thick kota stone slab in wall, dado in 15 mm thick [avg] cement mortar (1:3) including making suitable arrangement to hold the stone properly by brass / copper hooks including pointing in cement mortar (1:2) (1 cement : 2 marble dust) with admixture of pigments matching the stone shade, including grinding and polishing all complete as per direction of Engineer-in-charge including cost of materials, labour, scaffolding, staging, curing complete. [Using cement slurry for bedding @4.4 kg/Sq.m and for jointing @1.8 kg/Sq.m]In Ground floor. |
| 48 | In Firstfloor |
| 49 | In Secondfloor |
| 50 | Supplying& laying 20 mm designer chequered tiles of any shade and of approved quality as per IS: 1237: 1980 laid in patterns as directed in pavement, footpath including necessary underlay 25 mm thick average cement mortar (1:3) complete in all respect with all labour and materials >> Red varity >>(ii) 30mm thick |
| 51 | Neat cement punning about 1.5 mm. thick in wall, dado, window, sills, floor, drain etc. |
| 52 | (a) Applying 2 coats of bonding agent with synthetic multi functional rubber emulsion having adhesive and water proofing properties by mixing with water in proportion (1 bonding agent : 4 water : 6 cement) as per Manufacturer\"s specification |
| 53 | Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6 mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as per relevant IS codes. |
| 54 | Collapsible gate with 40mm x 40mm x 6mm Tee as top and bottom guide rail, 20mm x 10mm x 2mm vertical channels 100mm apart in fully stretched position 20mm x 5mm M.S. flats as collapsible bracings properly rivetted and washered including 38mm steel rollers including locking arrangements, fitted and fixed in position with lugsset in cement concrete and including cutting necessary holes, chasing etc. in walls, floors etc. and making good damages complete. |
| 55 | (a) Supplying, fitting and fixing steel rolling shutter profile type with 18 B.G . ofapproved type steel latche section 75mm wide, fitted with coil wire spring to necessiate the fitting of required Nos. of C.I. Pulleys on heavy type solid drawn seamless steel tube complete with locking arrangements both inside and outside specially builtup side guide channels including providing a hood for the steel rolling shutter in the room, painting two coats ofapproved aluminium paint over a coat of red lead primer complete. |
| 56 | Wood work in door and window frame fitted and fixed in position complete including a protective coat of painting at the contact surface of the frame exluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum should be correted upto three decimals). >>Sal :Malaysian InGround floor |
| 57 | InFirstfloor |
| 58 | Panel shutters of door and window, as per design (each panel consisting of single plank without joint), including fitting and fixing the same in position but excluding the cost of hinge and other fittings.(In case of non-supply of single plank, penal rate of reduction of 20% will be made)(iii) 35mm thick shutters with 19mm thick panel of size 30 to 45 cm.(b) Sishu, Gamar, Champ,Badam,Bhola, Mogra, Hallak. InGround floor |
| 59 | InFirst floor |
| 60 | Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite door frame as per approved section with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to safisfy IS: 4020 door testing performance criteria..(i) 66mm x 90mm |
| 61 | Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite door shutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria.In Groundfloor. (i) 32 mm thick InGround floor |
| 62 | InFirst floor |
| 63 | Supplying, fitting and fixing M.S. clamps for door and window frame made of flat bent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)(a) 40mm X 6mm, 250mm Length |
| 64 | Iron butt hinges of approved quality fitted and fixed with steel screws, with ISI mark.(vii) 100mm. X 58mm. X 1.90mm. |
| 65 | Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:(ii) 75mm long x 10mm dia. bolt. |
| 66 | (i) Door stopper.(Brass) |
| 67 | Anodised aluminium Aldrop / Sliding bolts of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 2681/66) fitted and fixed complete.(iii) 300mm x 16mm dia. bolt. |
| 68 | Anodised aluminium grip handle with base plate of approved quality fitted and fixed complete.(a) With base plate(i) 165mm grip x 12mm dia rod x 42mm plate x 3.2mm thick |
| 69 | Anodised aliminium D-type handle of approved quality manufactured from extruded section conforming to I.S. specification (I.S. 230/72) fitted and fixedcomplete:(a) With continuous plate base (Hexagonal/ Round rod)(iii) 100 mm grip x 12 mm dia rod. |
| 70 | Supplying , fitting and fixing hinge cleat in position excluding the cost hinge and other fiffitngs.b) with 75mm iron Butt-hinge>>iii) Local Sal. |
| 71 | (c) Supplying 6 levers \"Godrej\" Crystal Satine Mortice Lock with keys including fitting & fixing complete. |
| 72 | ii) Godrej Hydraulic door closer fitted and fixed complete. |
| 73 | Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/stagingwhere necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:6 cement mortar>> (c) 15 mm thick plaster InGround floor>>Out sidewall |
| 74 | InFirst floor>>Out sidewall |
| 75 | (i) With 1:6 cement mortar>>>(b) 20 mm thick plaster InGround floor |
| 76 | InFirstfloor |
| 77 | (ii) With 1:4 cement mortar>>(c) 10 mm thick plaster InGround floor>>Inside wall |
| 78 | InGround floor>>Outside |
| 79 | In Firstfloor>>Inside wall |
| 80 | In Firstfloor>>Out side |
| 81 | (ii) With 1:4 cement mortar>>(b) 15 mm thick plaster |
| 82 | Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails, including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.A) UPVC Pipes:(ii)110 mm. Dia. |
| 83 | B) UPVC Fittings:b) Plain Y(ii)110 mm. Dia. |
| 84 | C)Bend 87.5 degree>>110mmdia |
| 85 | d) Shoe(iii)110 mm. Dia. |
| 86 | Supplying, fitting and fixing Stainless Steel railing consist of 38mm dia and 900mm height vertical balustrade at every two alternative steps, 50mm dia top rail, 3 (three ) nos 19mm dia horizontal Strainless steel pipe and base/cover plate with Strainless Steel GRADE 304 containing 7.5% nickle (Interior Grade) Brushed/Mat finish, complete as per direction of the Engineer-in-charge. Weight of Strainless Steel railing per metre 6.5 Kg (approx) |
| 87 | Supplying, fitting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straightening if required, fixing lugs in cement concrete ( 1:2:4) with stone chips 20 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.(b) Openable steel windows as per IS sizes with side hung shutters and horizotal glazing bars. [The extra rate admissible for the openable portion only] InGroundfloor |
| 88 | In First floor |
| 89 | (v) Two point nose aluminium handle including fitting and fixing. |
| 90 | (vi) steel peg stay 300 mm long including fitting and fixing. |
| 91 | (viii) M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. |
| 92 | Supplying, fitting and fixing in position fibre glass panes of approvedvquality with resin, nail, clip etc. as per IS:12866-1989. (In all floors for internal wall & upto 6 m height for external wall)d) 3.0 mm thick (5.10 Kg/Sq.m) |
| 93 | Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface to receive Distemper/ Acrylic emulsion paintincluding scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC. (In Ground Floor)(a) One Coat i)Water based interior grade Acrylic Primer |
| 94 | Applying Acrylic Emulsion Paint of approved make and brand on walls and ceiling including sand papering in intermediate coats including putty (to be done under specific instruction of Superintending Engineer) : (Two coats) i) Standar QualityInGroundfloor |
| 95 | Applying Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface to receive decorative textured(matt finish) or smooth finishacrylic exterior emulsion paint including scraping and preparing the surface throughly, complete as per manufacturer\"s specification and as per direction of the EIC.(a) One CoatInGroundfloor |
| 96 | In First floor |
| 97 | Protective and Decorative Acrylic exterior emulsion paint of approved quality, as per manufacturer\"s specification and as per direction of EIC to be applied over acrylic primer as required. The rate includes cost of material, labour, scaffolding and all incidental charges but excluding the cost ofprimer.a) Normal Acrylic Emulsion---> In Ground floor (Two Coat) |
| 98 | b) Premium 100% Acrylic Emulsion. (two coats ) InGroundfloor |
| 99 | In First floor |
| 100 | (b) Priming one coat on timber or plasteredsurface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 101 | (a) Priming one coaton steel or other metal surface with synthetic oil bound primer of approved quality including smoothening surfaces by sand papering etc. |
| 102 | (A) Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary:(a) On timber or plastered surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 103 | (b) On steel or other metal surface :With super gloss (hi-gloss) -(iv) Two coats (with any shade except white) |
| 104 | M.S. gate of Jail type as perapproved design made of strong M.S. frame work, intermediate stiffeners and round / square bars or angles. M.S. sheet (not less than 14 gauge) gussets, cleats etc. including necessary riveting, bolting, welding, locking and hanging arrangements, fitting and fixing complete as per direction of the Engineer-in -charge.In ground floor. |
| 105 | Supplying, fitting & fixing granite slabs 15mm to 18 mm. thick with uniform texture & without decorative veins in columns, wall, facia,rise etc. with 15 mm thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction ofthe Engineer-in-charge including cost of all materials, labours, scaffolding, staging, curing and roughening of concrete surface complete. [Using cement slurry at back side ofgranite @ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m]In ground floor(a) Area of each Granite slab 0.6 to 1.0 Square meter. |
| 106 | M.S. works in brackets made from flats, angles, tees etc. to sizes specialy bent, twisted, forged; making holes drilled and fitted to rafter of trusses with necessary bolts, nuts, washer or screws etc. ( length of straight not less than 230 mm) |
| 107 | (a) Supplying, fitting galvanised 3 ply 12 gauge / 4 points line of barbed wire in fencing (holes already made in the body of the post) or fixed by staples tightening and fixing the wires in taut condition with straining bolts including the cost of cutting and of lapping joints in the wire as necessary but excluding the cost of galvanised staples,straining bolt and binding wire where necessary. |
| 108 | Supplying galvanised straining bolts (with eye at one end with double nuts and washers) fitted and fixed complete.(ii)12mmdia(a) 200mm long |
| 109 | Supplying galvanised staples fitted and fixed complete. (b)32.5 mm to 37.5mm size |
| 110 | Supplying fitting and fixing 600 mm (+/- 30 mm) diametre R.B.T nforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as \"C\" clips, R.B.T clips etc.) |
| 111 | M.S. structural works in roof trusses with tubular sections conforming to IS: 806-1968 & IS: 1161- 1998 cnnected to one another with bracket, gusset cleats as per design, direction of Engineer-in-charge complete including cutting to requisite size, fabrication with necessary metal arc welding conforming to IS: 816- 1969 & IS: 9595 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete.The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour reqired for the work including all incidental chages such as electricity charges, labour insurance charges etc. Payment to be made on the basis of calculated weight of structural tubular memebrs as specified in relevent IS code in finished work. Payment for gusset, bracket, cleat may be made by adding the actual weight of such items with weight of finished structural members. The rates are considered for a height of erection 8 m. / 2nd floor level from the ground. Add 1.5 % extra over the rate for each additional floor or 4m. beyond the initial 8 m. or part thereof.i) For trusses spanning up to 12.00 m |
| 112 | ii) For trusses spanning above 12.00 m and up to 20 .00 m |
| 113 | Supplying, fitting & fixing Zn-Al alloy (55% Al & 45% Zn) coating of150 grams per sq. metre (followed by colour coated on both side) steel sheet work having minimum yield strength of 550 Mpa oftrapizoidal profile of approved make as per IS: 15965: 2012 and IS: 14246: 2013 (excluding the supporting frame work) fitted and fixed with 55 mm & 25 mm self tapping screw, EPDM Washer 16 mm dia & 3 mm th. washer etc.complete with 150 mm end lap and one corrugation minimum side lap.(Payment to be made on area of finished work).(i) In Roof:- a) With 0.5 mm thick sheet |
| 114 | Aluminium sheet ridging fitted with self tapping screws, EPDM washers etccomplete.(Minimum 225mm end lapping)>>(A) 300 mm lapping each way>> (a) With0.71mm sheet |
| 115 | Galvanised iron sheets valley gutter with perimeter not less than 750 mm with 225 mm lap each way fitted and fixed with necessary bolts, nuts, screws, etc.complete. Valley gutter made of 0.63 mm. thick sheets. (300mm End lapping) |
| 116 | Sanitary and Plumbing WorksSupplying, fitting and fixing PVC pipes ofapproved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats ofpainting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately(A) For Exposed WorkPVC Pipes15 mm dia. medium quality |
| 117 | 20mm dia. medium quality |
| 118 | 25mm dia. medium quality |
| 119 | 32mm dia. medium quality |
| 120 | 40mm dia. medium quality |
| 121 | (b)For Concealed Work15 mm dia. |
| 122 | 20mm dia. |
| 123 | Supplying, fitting and fixing PVC pipes for underground work ofapproved make of Schedule 80 (medium duty) conforming to ASTMD - 1785 and threaded to match with GI Pipes as per IS : 1239 (Part - I). with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted including cost of all materials ,jointing materials, cutting pipes, making threads ,cutting trenches upto 1.5 metre below surface in all sorts ofsoil and refilling the same as directed complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.)32mm dia. Medium |
| 124 | Supplying, fitting and fixing shower of approved brand and make. (a) (i) Chromium plated round shower with revolving joint 100 mm dia with rubid cleaning system (Equivalent to Code No. 542(N) & Model-Tropical / Sumthing Special of ESSCO or similar brand). |
| 125 | Supplying, fitting and fixing gunmetal wheelvalve of approved brand bearing I.S.I. marking with fittings (tested to 21 kg per sq. cm.).(v) 40 mm dia |
| 126 | (vi) 32 mm dia |
| 127 | (vii) 25 mm dia |
| 128 | Supplying, fitting and fixing bib cock or stop cock.(a) (i) Chromium plated Bib Cock short body (Equivalent to Code No. 511 & Model - Tropical / Sumthing Special of ESSCO or similar brand). |
| 129 | (a)(ii) Chromium plated Bib Cock long body with wall flange with aerator (Equivalent to Code No. 512 & Model - Tropical / Sumthing Special of ESSCO or similar brand) |
| 130 | (b) (i) Chromium plated Stop Cock (Equivalent to Code No. 513(A) & 513(B) & Model - Tropical / Sumthing Special of ESSCO or similar |
| 131 | Supplying P.V.C. water storage tank of approved quality with closed topwith lid (Black) - Multilayer. (d) 2000 litre capacity |
| 132 | Labour for hoisting plastic water storage tank.(ii) Above 1500 litre upto 5000 litre capacity.First floor roof from ground level(a) Upto 1st story from G.L. |
| 133 | (b) Extra for each additional story |
| 134 | Labour for punching hole in plastic water storage tank upto 50 mm dia. |
| 135 | Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. |
| 136 | Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks, C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats of approved paint.(ii) 550 mm X 400 mm size |
| 137 | Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.(iii) 600mm long. |
| 138 | Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe, with PVC coupling at one end fitted with necessary clamps.(iii) 900 mm long |
| 139 | Supplying, fitting and fixing Waste fittings complete.(a) C.P. over brass (ii) 32 mm |
| 140 | Supplying, fitting and fixing dome shaped C.P. waste grating for urinals.(i) 32 mm. Flat back Urinal |
| 141 | Supplying, fitting & fixing Cast iron soil pipe only conforming to I.S. 3989 / 1970 and I.S. 1729/1964 with bobbins, nails etc. including making holes in the wall, floor etc. and cutting trenches etc. in any floor through masonry concrete, if necessary, and mending good damages with necessary jointing materials and painting two coats to the exposed surface with approved paint complete. (Measurement will be made along the center line of the total pipe line in fitted condition including specials,payment for specials & Painting will be paid seperately).(a) With valamoid joints including sealing with sand cement morter (4:1)upto quarter depth. (ii) 100 mm dia. (internal) |
| 142 | (iii) 75 mm dia. (internal) |
| 143 | Supplying, fitting & fixing Cast iron single branch equal with door conforming to I.S. 1729/1970 including joining and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will however be paid seperately). (a) With valamoid joints including sealing the top with cement mortar (4:1)(ii) 100 mm dia. |
| 144 | Supplying, fitting & fixing Cast iron double branch equal with doorconforming to I.S. 1729/1970 including jointing and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will be paid seperately).(a) With valamoid joints including sealing the top with cement mortar (4:1)(ii) 100 mm dia. |
| 145 | Supplying, fitting & fixing H.C.I. bend with door conforming to I.S.S. including jointing complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will be paid seperately).(a) With valamoid joints including sealing the top with cement mortar (4:1) (ii) 100 mm dia. |
| 146 | (iii) 75 mm dia. (internal) |
| 147 | Supplying, fitting & fixing approved patent vent cowl I.C.I. conforming to I.S.S and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will be paid seperately).(i) 100 mm dia. |
| 148 | Supplying, fitting and fixing cast iron extension pipes for using inraps only (connector) conforming to I.S.3989/1970 and 1729/1964 including lead caulked joints complete and painting two coats to the exposed surface with approved paint complete. (Payment of Painting will be paid seperately).(vii) 100 mm X 600 mm |
| 149 | Supplying,fitting and fixing cast iron \"P\" or \"S\" trap conformimg to I.S. 3989 / 1970 and 1729 / 1964 including lead caulked joints and painting two coats to the exposed surface. (Painting to be paid seperately). (A) \"P\" Trap(iii) 100 mm |
| 150 | Supplying, fitting and fixing with cement jointing (3:1) salt glazed stoneware pipe including excavation of earth upto 1.50 metre depth in all sorts of soil both mixed or unmixed and refilling (but excluding concreting at bottom and sides).(iii) 150 mm |
| 151 | Supplying, fitting and fixing C.I. round grating. (i) 100 mm |
| 152 | Supplying, fitting and fixing Anglo-Indian W.C. in white glazed vitreous china ware of approved make complete in position with necessary bolts, nuts etc.(a) With \"P\" trap (with vent) |
| 153 | Supplying, fitting and fixing Orissa pattern water closet in white glazed vitreous chinaware of approved make in position complete excluding \"P\" or \"S\" trap (excluding cost of concrete for fixing).(i) 580 mm X 440 mm |
| 154 | Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With \"P\" trap |
| 155 | Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete.(ii) 470 mm X 280 mm X 340 mm |
| 156 | Supplying, fitting and fixing Squating plate with integral flushing in white vitreous chinaware of approved make in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately).(i) 450 mm X 350 mm |
| 157 | Supplying, fitting and fixing Half round channel with or without outlet as required set in cement concrete (6:3:1) with jhama chips complete. (Payment of concrete will be paid seperately). (vii) 600 mm X 100 mm b) White vitreous chinaware |
| 158 | Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. (a) E.W.C. (ii) Plastic (hallow type) white |
| 159 | (b) Anglo Indian(ii) Plastic (hallow type) white |
| 160 | Supplying,fitting and fixing 32 mm dia. Flush Pipe of approved make with necessary fixing materials and clamps complete.ii) C. P. Flush Pipe |
| 161 | Supplying, fitting and fixing urinal flush pipe fittings of approved brand. (a) C.P. urinal flush pipe fittings range of one |
| 162 | Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver red as per I.S. 3438 / 1965 together with brass C.P. hinges. (i) 450 mm X 300 mm |
| 163 | Supplying, fitting and fixing liquid soap container.(a) Cromium plated. |
| 164 | Supplying, fitting and fixing towel rail with two brackets. (a) C.P. over brass (ii) 25 mm dia. and 600 mm long |
| 165 | Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling,15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials.i) With Pakur variety.>>with.(JSW/JSPL/SHYAM/SRMB/ BMASL/l/ELECTROSSTEEL/SSL) |
| 166 | Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cementlaster (4:1) to outside wall upto 200 mm below G.L floor finished with 25 m thick grey artificial stone over 100 mm thick .C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavation earth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from the chamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% by weight of cement with all costs of labour and materials. >>With Pakur Varity>> With (JSW/JSPL/SHYAM/SRMB/BMASL/ ELECTROSTEEL/SSL)(ii) For 20 users |
| 167 | Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cementconc (1:1.5:3) with stone chips with necessary reinforcement andshuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessaryangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials. With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia.(JSW/JSPL/SHYAM/SRMB/BMASL/ ELECTROSTEEL/SSL) |
| 168 | DEEP TUBE WELL Mobilization of Machinery and Equipments required for drilling, lowering the assembly, developing, perform yield test including supplying the all labour, transport, tools and tackles complete. |
| 169 | Charges for conducting vertical electrical sounding using a resistivity meter for ground water exploration including all labour charges, Transportation Charges and inter pretation at VES. data. |
| 170 | Drilling Bore Hole by a suitable DTH cum mud rotary combination rig with foam and mud drilling including collection of Litho-Logical surplus with maintaining the time log for drilling through different points as directed by E.I.C.(a) Drilling 250 mm. dia. Bore Hole suitable for lowering 200 mm. internal dia. casing pipe lowering through over burden of clay / consolidated moorum / consolidated laterite fragmented granite formation including lowering the casing pipe through over burden up to a depth of 30 mtr. Below ground level. |
| 171 | (b) Drilling through fussured consolidated hard rock strata with necessary Valve for hammer and with necessary air pressure ( not less than 200 sit ) from 30.00 mtr. to 200.00 mtr. below. |
| 172 | Development of the tube well and making yield test complete by a suitable diesel driven pump set and generator as per direction of E.I.C. (02 days).This work will be including the cost of hire charges of pump set, Generator set, required length of suction and delivery pipes, measuring instruments, making derrick arrangements, lowering and withdrawing charges of pump and column pipes, supply of fuel and lubricants, labour charges and all other materials including carrying charges. |
| 173 | Supply of PVC. Pipes & fittings Schedule 80 ( medium duty ) conforming to ASTMD - 1785. and threaded to match with G.I. Pipes as per IS : 1239 ( Part-I).(A) PVC. Pipes. 200 mm. dia. |
| 174 | Supplying, fitting and fixing G.I. Cap at top. (iii) 200 mm. |
| 175 | Supplying, fitting and fixing G.I. pipes of TATA make with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc. fitted with holder bats clamps, including cutting pipes, making threads, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials and two coats of painting with approved paint in any position above ground. (Payment will be made on the centre line measurements of total pipe line including all specials. No separate payment will be made for accesories, specials. Payment for painting will be made seperately) (A) For Exposed Work (e) (ii) 40 mm dia. medium quality |
| 176 | Collecting sample of water for bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc. complete in all respect as per direction. |
| 177 | SUBMERSIBLE PUMPSupply & installation of three phase 230 V, 1.5 H.P Open well Submersible Pump Motor set ( KSB-CORA 2C/21, CORA100+ UMAI -100 , 1.10/22, 1.1 KW) (Qty =1x2=2) |
| 178 | Supply & installation of three phase strating device suitable for KSB 1.5 H.p submersible Pump Motor set with three phase prevention facility on iron legs on wall (staring capacitor 100-120MFD, Running Capacitor-40 MFD) (Qty=1x2=2) |
| 179 | Supply & installation of 200 mm dia tube well cover made of 3mm thick of MS plate including necessary drilled holes , GI bends etc as required. (Qty =1x2=2) |
| 180 | Supply & fitting 50mmx6mm MS half round type holding clamp with 4 nos drilled holes on each half including S & F necessary nuts and bolts. (Qty=2x2=4) |
| 181 | Supply & laying 1.1 KV grade 3.5 core 25 sq. mm PVC/Ar Al cable from meter room to outdoor kisok (Qty=2x27.5m=55m) |
| 182 | LAND DEVELOPMENTEarth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)(c) (i) With carried earth arranged by the contractor within a radius of 1 km. including cost of carried earth. |
| 183 | FIRE EXTINGUISHER Suppling installation, testing & commissioning of ISI marked ABC Type fire extingguisher 6 kg capacity fire extinguisher conforming to IS 15683 including all brackets and all other charges. |
| 184 | Suppling installation, testing & commissioning of ISI marked& ISOcertified CO2Type fire extinguisher 4.5 kg capacity conforming to IS 15683 including all brakets and all other charges. |
| 185 | ELECTRICAL INSTALLATION WORKSSub-Head:-(Distribution Wiring)Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Piano key type switch (Anchor make) fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish. 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC Average run 8 mtr |
| 186 | Average run 12 mtr |
| 187 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. mending good damages to original finish 2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCOn Board |
| 188 | Average run 6 mtr |
| 189 | Sub-Head:-( Computer Point, Power Point)Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator & 20A switch type SP MCB (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S &F 240x200x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws aftermaking housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 190 | Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required |
| 191 | Supply & Fixing 240 V, 2 nos 5A, plug socket with separate 2 nos 5 A Piano key type switch (Brand Anchor) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board and bakelite/ perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making and necy connection with socket with 3 no. “Ph,N & E” copper bar.( for TV and setop Box) |
| 192 | Supply & Fixing 240 V, 6A, plug socket (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex coverand making necessary connections as required. [E-6/21] for wall Braket Fan |
| 193 | Supply & Fixing 240 V, 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board incl. S & F 100x100x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required [E-6/17(b)] for geyser point |
| 194 | Sub-Head:-( Power Socket, A.C. Starter, Top)Supply & Fixing 240 V, 25 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch with 2 Module PVC Modular type switch board with top cover plate flushed on wall and making necy. connections with PVC Cu wire and earth continuity wire etc.[E-17/5(a)] for ac and geyser point |
| 195 | Supply & Fixing 240 V,25 A, 3 pin Modular type plug top with indicator (Brand approved by EIC) & necy. Connections. [E-17/5(b)] |
| 196 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module PVC Modular type switch board with 4 Module top cover plate flushed on wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 197 | Sub- Head:-( VTPN,HTPN,SPN DB,Enclouser & Panel)SupplyingandfixingdoubledoorVerticalTPNMCB DistributionboardforMCCBincomerwithIP-42/43 protection, on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment4 way Up to 160A Make:-Legrand |
| 198 | 8 wayUp to 160A Make:-LegrandEnclosure (607914) |
| 199 | Supplying and fixing double door Horizontal TPN MCB Distributionboardwith IP-42/43protection,concealed inwallaftercuttingthewall&mending goodthe damagestooriginalfinishincl.Interconnectionwith suitable size of copper wire and neutral link & provision for earthing attachment 4 way Make:-Legrand |
| 200 | Supplying and fixing double-door SPN MCB Distribution Boardwith IP-42/43 protection,on angle iron frame on wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wireandneutrallink&provisionforearthing attachment.[NS]2+12 way Make:-Legrand |
| 201 | Supplying and fixing MCB SS enclosure with IP-20/30 protection,powdercoatedprovisionfor two/fourpole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection& provision for earthing attachment 2 Way |
| 202 | 4 Way |
| 203 | Sub-Head:- (ISO,MCB,MCCB, SFU)Supplyingandfixing240/415VMCBIsolatoron din rail of existing DBs and necessary connection.40 A DP Make:-Legrand |
| 204 | 63 A FP Make:-Legrand |
| 205 | Supplying and fixing 240/415 V MCBofBreaking capacity10kA&Ccharacteristicsondinrailof existing DBs and necessary connection6-32 A TPN Make:-Legrand |
| 206 | 6-32 A SPN Make:-Legrand |
| 207 | 63 ATP Make:-Legrand |
| 208 | 6-32 A TP Make:-Legrand |
| 209 | 6-32 A SP Make:-Legrand |
| 210 | Supplyingandfixing415VFourPoleMCCBof Breakingcapacity25kA/35kAwithfixedthermal and fixed magnetic / adjustable thermal and fixed magneticsettinginexistingDBs/enclosureand necessary connection.80 AMake:-Legrand |
| 211 | 100 AMake:-Legrand |
| 212 | Supplying andfixing415V,TPNonloadfront operated Changeoverswitch open execution type in SS enclosure/cubical with nuts bolts etc415V FP 63 A Make:-L&TCat No. CO10630OOO [NS] for Office Building |
| 213 | Sub-Head:- ( Supply of Cable)Supply of following 1.1 Kv grade XLPE insulated Armoured Aluminium cables-[NS ]4 core25 sqmm cable [NS] VTPN To HTPN |
| 214 | 4 core50 sqmm cable [NS] Panel To VTPN |
| 215 | 3.5 core95 sqmm cable [NS] for hot rolling Machine |
| 216 | Sub-Head:-( Laying of Cable)Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting |
| 217 | Laying of cable from 3/3½ core 35 sqmm to 50 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making holes etc. as necy., mending good damages and painting |
| 218 | Laying of cable above 3½ core 90 sqmm and upto 3½ core 150 sqmm on wall/surface including S & F MSclams with earthing attachment in 2 x 10 SWG GI (Hot Dip) Wire, making hole etc. as necy. mending good damages and painting |
| 219 | Sub-Head:- ( Cable Tray) Supply&FixingofperforatedGIcabletraywithperforationnot morethan 17.5%suspendedfromceilingincl.S&FGI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.200x50x1.25mm (18SWG) With 25x25x3mm angle iron support |
| 220 | Supply & Fixing of perforated GI cable tray bend with perforation not more than 17.5% suspended from ceilingwith two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support.200x50x1.25mm (18SWG) |
| 221 | Supply & Fixing of perforated GI cable tray tee with perforation not more than 17.5% suspended from ceilingwith two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support. 200x50x1.25mm (18SWG) |
| 222 | Supply&FixingofperforatedGIcabletraycrossmemberwith perforation not more than 17.5% suspended from ceilingwith two nos. suspenders & 25x25x3mm angle iron for supporting the cross member incl. S&F GI connector, 6mmdia MS suspender,bolts & nuts,steelfasteneretc.asrequiredofthefollowingsize.Incl.Al painting of MS support.200x50x1.25mm (18SWG) |
| 223 | Supply & Fixing of perforated GI cable tray reducer with perforation not more than 17.5% suspended from ceiling with two nos. suspenders&25x25x3mmangleironforsupportingthereducer incl. S&F GI connector, 6mm dia MS suspender, bolts & nuts, steel fastener etc. as required of the following size. Incl. Al painting of MS support (e)]200x50x1.25mm (18SWG) |
| 224 | Sub- Head:-(Gland, Socket)Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below :upto 4 core25 sqmm |
| 225 | upto 4 core50 sqmm |
| 226 | upto 3½ core95 sqmm |
| 227 | Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials :4 core25 sqmm cable |
| 228 | 3½ core 50 sqmmcable |
| 229 | 3½ core 95 sqmmcable |
| 230 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. 1.5sqmm [NS] |
| 231 | 2.5sqmm [F-5/9(i)] |
| 232 | 4 sqmm [F-5/9(ii)] |
| 233 | 6 sqmm [F-5/9(iii)] |
| 234 | 10sqmm [F-5/9(iv)] |
| 235 | Sub-Head:- ( Copper Wire, polythine Pipe, inpection box)Supplying and Drawing 1.1 KV single core stranded \"FR\"PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) of the following sizes in the prelaid polythene pipe and by the prelaid GI fish wire and making necy. connection as required 3 x 22/0.3 (1.5 sqmm) |
| 236 | 2x36/0.3 (2.5 sqmm) + 1x22/0.3 (1.5 sqmm) as ECC [E-9/1(s)] for Computer and power point |
| 237 | 2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC [E-9/1(v)] for AC point |
| 238 | 2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC [E-9/1(y)] for HTPN to SPN DB Connection and DP Enclouser |
| 239 | 3x80/0.4 (10 sqmm) + 2x84/0.3 (6 sqmm) as ECC [E-9/1(c1)] for VTPN to TPN Enclouser |
| 240 | Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction) 19mm dia 3mm thick Polythene Pipe |
| 241 | 25mm dia 3mm thick Polythene Pipe |
| 242 | Cutting Channel of size (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 19 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI \"U\" hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles 19 mm dia 3 mm thick polythene pipe without earth continuity wire |
| 243 | Sub-Head:-( Supply Light, Fan, Bulb)Supply of 4\" 18W T8 LED tube light with complete set (Make:- Philips TMC 501 P 1xT-LED 22W P3241, includingMaster LED tube 1200 mm 18W 2100 lumen/Bajaj/ Wipro |
| 244 | Supply of 4\" 2x18W T8 LED tube light with complete set (Make:- Philips TMC 501 P 2xT-LED 22W P3241, includingMaster LED tube 1200 mm 18W 2100 lumen /Bajaj/ Wipro |
| 245 | Supply of 230 V, AC Ceiling fan complete with blade, canopy, down rod upto 1 ft.1200 mm (48\") sweep, Make- Orient Summer Breeze/Crompton[NS] |
| 246 | Supply of 230 V, AC Ceiling fan complete with blade, canopy, down rod upto 1 ft.900 mm (36\") sweep, Make- Orient Summer Breeze/Crompton[NS] |
| 247 | Supply of wall bracket fan complete with all accessories havin the following specifications- Make- Orient 18\" (450 mm )Tornado Wall II /Crompton[NS ] |
| 248 | Supply of9\"\" sweep 1370rpm AC exhaust fan(EPC heavy duty)[NS] |
| 249 | Supplyof12\"\" sweep 1420rpm AC exhaust fan(EPC heavy duty)[NS] |
| 250 | Supplying & Fixing LED bulk head light fitting (Make:-Philips, Model:-WT140W LED 7S CW PSU S1 PC/Bajaj/ Wipro |
| 251 | Supply of10W LED lamp(Make:Crompton/ Philips / Havells ) [NS] |
| 252 | Sub-Head:-( Fixing Tube and Led street light Light,ceiling fan, Exhaust Fan)Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 253 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length. |
| 254 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire. |
| 255 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 1x24/0.20 mm (1.5sqmm.) flexible copper wire |
| 256 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 23 cm (9\") |
| 257 | 30 cm (12\") |
| 258 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length [C-4/29] |
| 259 | Supply & Fixing louver shutter on wall with necy. bolts & nuts (6 mm dia x 62 mm long) For Al 23 cm (9\") |
| 260 | 30 cm (12\") |
| 261 | Fixing only lamp |
| 262 | Supply & Fixing angular batten holder (Anchor) on 75mm dia PVC round block / round bakelite on wall/ceiling. |
| 263 | Sub-Head:-( Call Bell, Fan clamp,Fan Regulator)Supplying & Fixing ofBox type fan clamp of150mm dia & 80mm depth made of 16 SWG CRCA sheet with one end duly sealed by cover, properly welded, incl. S&F12mmdia600mmlongMS rod duly bent by heat treatment at the centre position of rod to grip fan bobbin properly, incl. binding the rod and fan box with reinforcement by 22SWGsteel bindingwire,incl.supplying&coveringthebox withalkathenesheet,placedinordertopreventconcretefrom entering the box. |
| 264 | Supplying & Fixing 240 V AC/DC superior type Multitune ( min 10 nos. tune) Call Bell (Anchor) with selector switch for single/Multi Tunes mode, Battery operated on HW board. |
| 265 | Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connectionsetc. [E-6/18(a)] |
| 266 | Sub-Head:-( Earthing)Excavation of soil for installation of Earth Electrode and filling & ramming. For Morrum Soil |
| 267 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:By ISI-Medium GI pipe [G-1/2(a)] |
| 268 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts,nuts, washers, spacing insulators etc. as required. |
| 269 | Connecting the equipments to earth busbar including S & F GI (Hot Dip) wire of size as below on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damagesSolid GI Wire No. 4 SWG |
| 270 | Sub-Head-Panel SITC of CPRI approved cubicle type compartmentalised floor cum wall mounted LT panel board of suitable size and shape for existing panel room and made of 2mm thick CRCA sheet steel CNC fabricated panel & followed by nine tank pre-treatment of entire enclosure with powder coated finish paint (RAL 7032) having electrolytic tinned copper Bus-bar and following equipment & accessories. Protection rank required of panel is IP-54.Incoming :415V, 250A 4 Pole 36 KA Thermal Magnetic MCCB with O/L & S/C protection, extended rotary handle, Spreader Terminal etc. [Make- L & T orEq. Siemens/ Schneider) - 1 no.[D-8/10]Bus-bar: 415V 315A HorizontalBus-bar system with EPR support for main power distributionby S&Felectrolytic tinned copper bars of size 4 x 40mm x. 5 mm. The Bus-bar shall have uniform cross section throughout the lengthAll joint must be of bolted type( Cadmium plated high tensile bolt)construction. Proper colour code to be provided by PVC heat shrink sleeves -1 nosOutgoing:-a)415V,63A 4 Pole 36 KA Thermal Magnetic MCCB with O/L & S/C protection, extended rotary handle, Spreader Terminal etc. ( Make- L&T orEq. Siemens/ Schneider)- 2 nos.Outgoing:-b)415V,100A 4 Pole 36 KA Thermal Magnetic MCCB with O/L & S/C protection, extended rotary handle, Spreader Terminal etc. ( Make- L&T orEq. Siemens/ Schneider)- 3 nos..c)415V,160A 4 Pole 36 KA Thermal Magnetic MCCB with O/L & S/C protection, extended rotary handle, Spreader Terminal etc. ( Make- L&T orEq. Siemens/ Schneider)- 1 no. . |
| 271 | c)415V,20A 4 Pole 36 KA Thermal Magnetic MCCB with O/L & S/C protection, extended rotary handle, Spreader Terminal etc. ( Make- L&T , Cat No. CM97919OOD2OG orEq. Siemens/ Schneider)- 2 no. |
| 272 | Constructional Details:The panel to be made by 2mm thick CRCA sheet steel. The cable gland packing should be 2.5mm thick and having required nos. of hole for cable entry. Cable entry provision to be made from the top and bottom of the panel with individual cable end box of 250 mm width. All required cutting,sloting and punching for indicating arrangement , bend etc. shall be done by Automatic CNC Machinefor good finish. The panel surface must be pre-treated through 9 tank treatment process before painting by powder coating paint by electrostatic charging system and again to be dried up through heat chamber at 200 degrees Celsius to keep the paint on panel surface with adequate hardness. The panel shall have suitable size integral and removable lifting lug in required nos with complete base channel. All doors should be hinged type railway type locking arrangement and all opening shall be properly gasketted. |
| 273 | Metering & Indication arrangement:a) 0-500VDigital Voltmeterwith selector switch- 1 no.b) 0-250 A Digital Ammeterwith selector switch-1 No.c) CT- 250/5A,15VA, Accuracy class -1.0 (Kappa make) -3 nos.d) LED indicating lamp (Siemens make /Esbee make) –3 nos (RYB)e) 2 Amp SP MCB- 3 no.f) EI danger board [Size 8\" x 12\"] – 1 no.All wiring for metering & indication to be done with 1.1KV grade PVC insulated stranded FRLS copper wire of size 1.5 sq mm, each wire shall have ferrules & lugs at both end. Metering & indication wires shall be nearly bunched separately and adequately supported so as to prevent stress and strain on termination. The material and design should be approved by EIC before fabrication. |
| 274 | Supplying andfixing415V,TPNonloadfront operated Changeoverswitch open execution type in SS enclosure/cubical with nuts bolts etc415V FP 63 A Make:-L&T [NS] |
| 275 | 415V FP 250A Make:-L&T [D-2/3(b)] |
| 276 | Sub-Head:-( S&F AC )Supply, Installation, Testing & Commissioning of split type AC machines havingCooling Capacity range (5.2 kw - 5.3 kw), with fixed speed rotary compressor, refrigerant gas R32/R410 BEE star rating -3 (EER range 3.5 to 3.99), Air flow range CFM (560-600), both condenser and cooling coils made of copper tube connecting chord with plug top confirming to IS 1391 (Part-I & Part-II) with all amendments (Make- Mitsubishi Electric/Daikin/O-General/ Carrier/ Voltas/ Blue Star/LG/Panasonic/Hitachi/Mitsubishi Heavy) |
| 277 | Supply and Installation of M. S. angle Bracket, making a hole including fixing accessories for providing condensing unit and cooling unit mending the good damages. |
| 278 | Supply and Laying 5/8\" (15.88 mm.) dia (Soft drawn) Cu. Pipes (As per standard BS864 or ANSIB 16.22)mm incl. 19mm thick insulation. |
| 279 | Supply and Laying 1/4\" (6.4 mm) dia (Soft drawn) Cu. Pipes(As per standard BS864 or ANSIB 16.22) incl.19mm thick insulation. |
| 280 | Supply and fixing of1.1 KV single core stranded \"FR\" PVC insulated & unsheathed copper Cable of the following size(Brand approved by EIC) incl. necy. fittings as required4 core x 4 mm²Round PVCinsulated copper cable(Make- Polycab/Haavells/ Gloster/ Finplex /RR Kable/KEI). |
| 281 | Supply & laying PVC Drain Pipe 25mm dia with 6mm thick NitrileRubber Insulation (Make: Suprime/Oriplast) |
| 282 | Add 12% GST(Excluding Sl No. 108 to 111 , 116 to 120 and 121.01 to 121.02) |
| 283 | Add LW CESS @ 1% (Excluding Sl No. 108 to 111) |
AI Tender Summary
Tender Timeline
Oct 11, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedNov 01, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 03, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender