Military Engineer Services-MES has published Repair Replacement Of Ci Soil Waste Incl Fitting And Replacement Of Rcc Water Tanks With Pvc Tanks In Kse Area And Repair To Backwash And Sludge Water Drain Interlocking Path Culvert At Bml Under Age Br-I Patiala Ge North Patiala. Submission Date for this Tender is 07-11-2022. PVC Tank Tenders in patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

34300532
Corrigendum : Repair Replacement Of Ci Soil Waste Incl Fitting And Replacement Of Rcc Water Tanks With Pvc Tanks In Kse Area And Repair To Backwash And Sludge Water Drain Interlocking Path Culvert At Bml Under Age Br-I Patiala Ge North Patiala
Open Tender
Indian
Punjab
patiala
07-11-2022

Tender Details

Repair Replacement Of Ci Soil Waste Incl Fitting And Replacement Of Rcc Water Tanks With Pvc Tanks In Kse Area And Repair To Backwash And Sludge Water Drain Interlocking Path Culvert At Bml Under Age Br-I Patiala Ge North Patiala

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 31-Oct-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 90000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Repair/Replacement of CI Soil waste incl fitting and replacement of RCC water tanks with PVC tanks in KSE area and Repair to backwash and sludge water drain interlocking path/culvert at BML under AGE BR-I Patiala, GE North Patiala.
Sl. No. Item Description
1Demolotion of reinforced cement concrete of any description and in water storage tank of any size/capacity/description/position located on terrace of the building including moving the demolition portions to low laying area complete all as specified and directed.
2Demolition of Brick work or stone/boulder masonary built in CM including all quoins, arches, pillers etc complete all as specified and directed.
3M&L for Brick Work with sub class "B" bricks straight or curved on plan exceeding 6m mean radious built in CM 1:6 complete all as specified and directed.
4M&L 25mm thick cement concrete Type B1 1:2:4 (12.5mm graded aggregate)as in floor finished rough to recieve floor finishes etc complete all as specified and directed.
5S&F doubled layered rotational moulded polyethyene water storage tanks (Cylindrical vertical with closed top / cover) 500 ltrs capacity hoisted and fixed in position all as specified including ball brass valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC tank complete all as specified and directed.
6S&F 25mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
7S&F 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed.
8Taking up or down existing steel tubing and connections, 20mm bore complete all as specified and directed.
9Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed.
10S&F 20mm bore steel water tubing medium grade galvanised with all fittings and fixed compete to walls and ceiling or liad in floor etc and incl cutting chases if required for concealed water tubing and making good, cutting not exc 10 cm girth etc complete all as specified and directed.
11Cast iron Nahani trap 100 mm dia with long arm n less than 450mm grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and directed.
12Cast iron soil, waste and vent pipe, 100mm bore, sand castin any length, with or without ears, with cement joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections hight upto 12mtr complete all as specified after taking down of existing unserviceable pipe fixed in repair complete all as specified and directed. Note : Scaffolding, T&P, Safty measures (Belts + ropes + ladders) should be included in all BOQ rates for Min 12 mtr height. (Not paid seperately).
13Cast iron soil, waste and vent pipe, 75mm bore, sand castin any length, with or without ears, with lead joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections hight upto 12mtr , fixed as in repair complete all as specified and directed. Note : Scaffolding, T&P, Safty measures (Belts + ropes + ladders) should be included in all BOQ rates for Min 12 mtr height. (Not paid seperately).
14Cast iron soil, waste and vent pipe, 50 mm bore, sand castin any length, with or without ears, with lead joints, fixed to walls with and including stack clamps, nuts , bolts etc. and making necessary connections, hight upto 12mtrfixed as in repair complete all as specified and directed. Note : Scaffolding, T&P, Safty measures (Belts + ropes + ladders) should be included in all BOQ rates for Min 12 mtr height. (Not paid seperately).
15S&F holder battern clamp 100 mm diaof 50mm by 5mm flat iron and 16mm dia round iron stays. Including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
16S&F CI Bends/Reducer (any radius), for 100mm bore CI piipes diminishing pieces or tapers (larger bore measured) fitted with oval access doors complete all as specified and directed.
17S&F cast iron junction combination "T" / "Y" equal or unequal  for 100mm bore with access door as in repair complete all as specified and directed.
18M&L  for cast iron cowls of 100 mm dia  complete all as specified and directed.
19S&F holder battern clamp 75 mm diaof 50mm by 5mm flat iron and 16mm dia round iron stays. Including bolts and nuts and securing ends of stays to wall or roof complete all as specified and directed.
20S&F CI Bends (any radius), for 75mm bore CI piipes diminishing pieces or tapers (larger bore measured) fitted with oval access doors complete all as specified and directed.
21S&F cast iron junction combination "T" / "Y" equal or unequal  for 75mm bore with access door as in repair complete all as specified and directed.
22M&L  for cast iron cowls of 75 mm dia  complete all as specified and directed.
23S&F CI Bends (any radius), for 50mm bore CI piipes diminishing pieces or tapers (larger bore measured) fitted with oval access doors complete all as specified and directed.
24S&F cast iron junction combination "T"/ "Y" equal or unequal  for 50mm bore with access door as in repair complete all as specified and directed.
25M&L  for cast iron cowls of 50 mm dia  complete all as specified and directed.
26S&F CI reducer, for 100mm bore to 75mm bore CI piipes diminishing pieces or tapers (larger bore measured) fitted with oval access doors complete all as specified and directed.
27S&F CI reducer, for 75mm bore to 50mm bore CI piipes diminishing pieces or tapers (larger bore measured) fitted with oval access doors complete all as specified and directed.
28Salt glazed stone-ware gully traps,Centrifugal type 150 x 150mm size , square or roundmouthed, type "P" or "S" incl CI grating fixed in repair complete all as specified and directed.
29S&Fvitreous china wash down water closet pan floor mounting (pedestal pattern/EWC) P trap white/ivory including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe CP 32mm dia and incl. plastic seat cover, complete all as specified and directed.
30Vitreous china squatting pan of Orissa patten size 580 x 440 white with (C I P trap long size) joint run and leadfront or back inlet with integral footrest including connection to trap and to flushing pipe,anti-syphonage pipe, etc, fixed in repair complete and making good to floor in CM 1:3 complete all as specified and directed.
31S&F health faucet (ABS Body) with 1.25 metre long flexible tube and ABS wall hook including making connections and fixed in position complete all as specified and directed.
32S&F PVC(HDPE) SWR , 110 mm bore, single socketed in any length with rubber ring joints using solvent as per maunfacture instruction,fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc as in repairs after taking down existing damaged CI rain water pipe complete all as specified and as directed including P or S Tees traps complete all as specified and directed.
33PVC (SWR) bends/tees of any radius for 110mm bore with access door as in repair complete all as specified and directed.
34Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises complete all as specified and directed.
35M&L for Non skid ceramic (coloured tiles) of size 300 x 300 x7mm thick in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match scred 15 mm thick in cement mortar (1:4) complete all as specified and directed.
36M&L for Glazed ceramic tiles 200 x 300mm x 7mm thick coloured on vertical surfaces set and jointed in neat cement slurry and pointed in white cement to match including 10 mm thick rendering of CM 1:4 complete all as specified and directed.
37M&L for prerparing steel and iron surfaces of any description and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and as directed.
38Demolition of cement concreteun -reinforced in ground floors and pavings n.exc 15cm thickness complete all as specified and directed.
39M&L for Plain cement concrete 1:7:12 mix, type E-2 (using 40mm graded Brick aggregate) as in filling of sunken portion complete all as specified and directed.
40M&L for Rendering 15 mm thick in cement mortar 1:3 , mixed with water proofing compound, on brick or concrete surfaces of wall of sunken portion, trowelled to even and smooth finish without using extra cement with WPC paid and measered sepretly complete all as specified and directed.
41Applying three coats of brush bond acrylic based cementitious material of approved quality for sunken portion treatment all as per manufacturer instruction and providing 200 micron thick polythene film over 85/25 grade bitumen layer @ 0.5 kg /Sqm complete all as specified and directed.
42Providing 25 mm dia GI pipe medium grade spouts 60 cm long complete all as specified and directed.
43M&L for RCC (1:2:4) type B-1 using 20mm graded mechanically crushed stone aggregate as in precast slabs for covers of manholes and set in CM1:6 incl necessary from work hand placing of manhole cover on varsion complete all as specified and directed.
44Excavation in trenches not exc 1.5 mtr wide and not exceeding 1.5mtr depth for foundation in soft/loose soil & getting out complete all as specified and directed.
45M&L for Forming embankments including raising (or lowering) earth, spreading in layers n exc. 30 cm thick; watering, ramming/rolling and finishing to required size, shape, etc., n exc. 1.5m high from base complete all as specified and directed.
46M & L for reinforced concrete pipes of 300 mm dia, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed.
47M & L for Concrete bed to drain pipes including packing under and haunching against the sides of pipes with concrete after they are laid and tested,in Cement concrete 1:4:8 type D2 for Pipes 300 mm dia class NP3 complete all as specified and directed.
48M&L for hardcore of guage exc 63mm but n.exc. 100 mm (broken stone boulder) deposited, spread and levelled in layers n.exc. 15cm thick, watered and rolled / rammed to a true surface complete all asspecified and as directed.
49M&L for 75 mm thick PCC type C-2, (1:3:6) using 40mm graded stone agrregate as in sub base of floors etc complete all as specified and directed.
50S&F for machine pressed precast concrete interlocking paver block any shape and size with grey cement and no pigment confirming to IS 15658-2006 of 80mm thickness M-40 grade over and including 25mm thick sand cushion complete all as specified and as directed.
51M&L for PCC 1:2:4 type B-0 (using 12.5 graded stone aggregate) as in precast kerb stone jointed with CM 1:4 , rounded or chamfered on edges complete all as specified and as directed.
52M&L for PCC in lintels upto 1.5 m clear span, cills, steps; seismic & other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, as directed type B1 (1:2:4) using 20 mm graded aggregate complete all as specified and as directed.
53M&L for PCC 1:4:8, type D-2 using 40mm graded stone aggregate, as in foundation or sub baseetc. complete all as specified and directed.
54M&L for PCC 1:2:4, type B-2 using 40mm graded stone aggregate, as Cement concrete in surface channels and drains etc. complete all as specified and directed.
55M&L for brick work in CM 1:4 with sub class "B" bricks staight or curved on plan to any raidusin half brick thick wall builtin complete all as specified and directed
56M&L for brick work in cement mortar (1:6) using old bricks staight or curved on plan exc 6.0 m mean raidus
57M&L for Raking out joints/ pointing to brick work or brick tiles, laid flat, in floors, surface channels, roofs, etc. complete all as specified and directed.
58M&L using CM 1:3 Flush pointing to brick walls completeall as specified and directed.
59Demolition of reinforced cement concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided forLaid, bedded & pointed in any mortar, complete all as specified and directed.
60M & L for flat formworkfor rough finished surfaces of concreteto soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) complete all as specified and directed.
61M & L for reinforced cement concrete (nominal mix) Type B1 1:2:4(20 mm graded aggregate) in beams, cantilevers, slabs, lintels over 1.5m span fairly finished smooth complete all as specified and directed.
62M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
63M&L for reinforced concrete pipes of 600 mm dia, class NP3, laid and jointed complete with collars and jointed complete in cement mortar (1:1) complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail