Retrofitting Water Supply Scheme At Sajai, Devgaon, Korawale And Madakepada, Taluka Murbad, District Thane.
Tender Value
4.44 Crore
Estimated cost
Bid Submission
25 Oct 2022
0 days left
EMD
2.22 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
murbad → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Retrofitting Water Supply Scheme At Sajai, Devgaon, Korawale And Madakepada, Taluka Murbad, District Thane.
BOQ
| Sl. No. | Item Description |
| 1 | SAJAISub Estimate No.1 - Feeder Main Item No.1 :- Providing D.I.pipes (push on joints pressure pipes of D.I. of following class and diameters confirming to the I.S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality) excluding GST levied by GOI & GOM in all respect includingThird party inspection charges of TPI Agency approved by MJP includingTransit insurance, Railway Freight,Unloading from railway wagon, Loading into Truck, Transportation to departmental store, unloading,stacking etc.completed as directed by Engineer incharges (IS8329/2000 for pipes and IS 158/1969 and IS12820/1989 or latest edition / revision with amendments for Rubber Gaskets.100 mm Dia DI Pipe K-7 |
| 2 | Item No.2 :- Providing DI specials etc. complete as per direction of engineer in charge. |
| 3 | Item no. 3:- Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete PN-1.6(Without bypass arrangement) Sluice valves 100 mm Dia. |
| 4 | Item No.4 :-Providing, erecting, connecting double flanged short body pattern tye manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS 210 Gr. CF 200generallyconforminginBS5155,Syntheticrubber faced ring secured on disc by retaining ring with stainless steelscrewstubshaftofstainlesssteelridinginTeflon bearings excluding C.C. foundation/ structural steel support confirming to IS 3095-1991. Sluice valves 100 mm Dia. For washout |
| 5 | Item No.5 :- ProvidingandsupplyingAirvalvesasperIS-10845and MJP’s standard specifications of approved mark and quality offollowingdiametersincludingalltaxes (Central andlocal),railwayfright,inspectionchargesunloading fromrailwaywagons,loadingintotruck,transportation upto departmental stores/ site, unloading and stacking etc. complete.Air valves single ball, flanged/screwed Type PN1.6. Air valves 25 mm Dia |
| 6 | Item No. 6 - Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. EARTHSOIL |
| 7 | Item No. 7 - Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Hard murrum |
| 8 | Item No. 8 - Excavation in Hard rock masses mechanically, including lift upto 1.5 M including trimming and levelling the bedremoving the excavated material upto a distance of 50 metres beyond the area and lift as below stacking by as directed by Engineer-in-charge, normal dewatering excluding backfilling, etc. complete. Hard Rock |
| 9 | Item No. 9 - Excavation for foundation / pipe trenches in hard rock by controlledblasting,includingtrimmingandlevellingthe bedbychisellingwherenecessaryandremovingthe excavatedmaterialandstackingitinmeasurableheaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. Lift 0 to 1.5 M Hard Rock |
| 10 | Item No.10 :-Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers including watering and compaction complete. |
| 11 | Item No.11:- Lowering laying and jointing with SBR ruber gaskets D.I. S/S pipes of various classes with CI/MS specials of following diameter in proper position,grade and alignment as directed by Engineer-in-charge including conveyance of material from stores to site of work, including cost of jointing. 100 mm Dia DI Pipe K-7 |
| 12 | Item No.12 :- Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including nut bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves). Sluice valves 100 mm Dia. |
| 13 | Item No.13:-Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) Sluice valves 100 mm Dia. For washout |
| 14 | Item No.14:-Lowering, Layingand fixing in proper alignment and position all types of C.I. Air valves as directed by Engineer in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc complete. Air valves 25 mm Dia |
| 15 | Item No.15:-Providingandfixinginpositionairvalveshaftincluding providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providingPCCblockofM-150concrete150mmthick aroundtheairvalveteeincludingencasingofvertical shaft in PCC M-150 as shown in type design together with providingandmakingflangedjointswhereverrequired and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.) upto 150 mm on Murum & harder strata |
| 16 | Item No.16:- ProvidingandlayinginsitufollowinggradesofC.C.of trap/granite/quartzite/gneiss metal for foundation and bedding including dewatering, form work, compacting and curing, finishing etc. complete. |
| 17 | Item No.17:-ProvidingandconstructingB.B.masonryvalvechamber with 15 cm thick 1:3:6 proportion PCC bedding, including excavation, B.B. masonry in C.M. 1:5proportion 12 mm thickcementplasterincm1:4proportiononbothsides with providing and fixing C.I. manhole frame and cover in RCC1:2:4copingorcmthickslabetc.completeas directed by Engineer-in-charge. |
| 18 | Item No.18 :- Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15 cm layers with all leadsand lifts including consolidation, surcharging, etc. complete |
| 19 | Item No.19:- Hydraulic testing of C.I./D.I .pipeline to specified pressure including cost of all materials and labour and water for testing forspecified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments,labour,operation charges,etc.required for testing. Therate under this item shall also include cost of retesting, if necessary and reinstating tooriginal position using water supplied by the contractor. 100 mm Dia DI Pipe K-7 |
| 20 | Item No.20:- Giving satisfactory hydraulic testing of following C.I. D / F Reflex valves, Butterfly valves and Sluice valves. Sluice valves 100 mm Dia. |
| 21 | Sluice valves 100 mm Dia. for Washout |
| 22 | RCC Well - Excavation in general in soft material comprising of soft soil, soft murum, sand,hard murum with boulders in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, Supply Well, etc. for lift 0 to 1.5M and lead of 150 M including barricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-incharge, etc. complete excluding refilling.Lift 0.00 M to 1.50 m |
| 23 | Lift 1.50 M to 3.00 m |
| 24 | Lift 3.00 M to 4.50 m |
| 25 | Lift 4.50 M to 6.00 m |
| 26 | Excavation in general in hard material comprising of soft rock, hard rock, Manjara rock, etc. by blasting / controlled blasting, chiselling as required in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, Supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including barricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-incharge, excluding refilling.Lift 6.00 M to 7.50 m |
| 27 | Lift 7.50 M to 9.00 m |
| 28 | Lift 9.00 M to 10.50 m |
| 29 | Providing and laying in situ Cement concrete in proporation .... of trap metal for foundation and bedding, including balling out water manually, formwork, compacting and curing etc. complete.P.C.C 1:2:4 ( M-15 ) |
| 30 | Providing & costing inconstructingin situ. C.C of trap granite/ quartzite / gneiss/ metal of approved quality of R.C.C. work as per detailed drawing & design or as directed by Engg. in charge including dewatering , ceterind from work,compacting, finishingthe formed surface withC.M. 1:3 of sufficient minimum thickness to give a smooth & even surface wherever necessary or roughening if spetial finish is to be provided & curing etc. complete. ( By weight batching & mix design for M-250 & M-300 only use of L&T, ACC Ambuja, Birla Gold, Manikgad, Rajashree etc. cement is permitted excluding M.S or Tor reinforcement in R.C.C. M-250grade.1) R.C.C. M-250 for Beam |
| 31 | 2) R.C.C. M-250 for walkway slab |
| 32 | 3) R.C.C. M-250 for vertical wall |
| 33 | Providing & fixing in position steel bar reinforcement of various diameters for R.C.C. Pipes,caps,footing, foundation, slab, beams, columns, canopies, staircase, newels,chajjas, lintels,pardies,coping,fine arches etc. as per detailed designs, drawing & schedule s including cutting, bending, hooking the bars,bindingwith wires or tack welding & supporting as required etc. complete (including cost of binding wire). Corrosion Resistant Steel |
| 34 | Providing & laying weep holes of 80 mmAC/PVC pipe as per drawing for abutment returns, return wallsetc. complete. |
| 35 | Dewatering the excavatyed trenches and pools of water by using pumps and other devices including disposing of the water to safe distance as directed by Engineer-in-Charge (including cost of machinerylabour fuel )etc complete. |
| 36 | Providing uncoursed rubble masonry of t rap / granite / quartzite /gneiss stones in cement mor tar 1:6 in foundation and plinth of innerwalls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and water ing etc.complete. |
| 37 | Providing internal cement plaster 20mm. thick in two coats in cement mor tar 1:3 wi thout neeru finish, to concrete, br ick sur face, in all posi t ions including scaffolding and cur ing etc. complete. |
| 38 | Reffiling the trenches with approved excavated material from foundation in 15cm to 20cm layers including watering and compaction etc. complete. |
| 39 | Providing and fixing in position C.I. dapuri steps or 22 mm dia. M.S. bar step with proper anchorage, etc. and providing and applying 3 coats of anticorrosive paint, etc complete as directed by Engineer- in-charge. |
| 40 | Providing and fixing 90 cm x 60 cm Marble plate engraving 10 cm. height letter, figures including painting the lefters/figures with approved colour and shade complete |
| 41 | Providing structural steel work in rolled sections like joists, channels, angles,tees, etc. as per detailed designs and drawings including fixing in position without connecting plates, braces, etc. and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, etc. complete. (Bd-C-2/275) |
| 42 | Sub Estimate No.3 - Switch Room Item No.1 :- Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259) |
| 43 | Item No.2 :- Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) |
| 44 | Item No.3 :-Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) |
| 45 | Item No.4 :-Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) |
| 46 | Item No.5 :- Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete |
| 47 | Item No.6:- Providing flush grooved pointing with cement mortar 1:3 for stone masonry work including scaffolding and curing etc. complete. |
| 48 | Item No.7 :-Filling in plinth and floors / trenches with contractor\"s murum for bedding in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-11/263) |
| 49 | Item No.8:- Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 50 | Item No.9:-Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 51 | Item No.10 :-Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) |
| 52 | Item No.11:- Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) |
| 53 | Item No.12 :-Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 54 | Item No.13:-Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 55 | Item No.14 :-Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 56 | Item No.15:-Providing and fixing in position steel bar reinforcement of various diamenters for RCC piles, caps, footing, foundation, slabs, beams, columns, canopies, staircases, newels,chjjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking he bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) |
| 57 | Item No.16:-Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 58 | Item No.17:-Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 59 | Item No.18:-Providing and laying cement concrete flooring 50mm thick with cement concrete M-25 laid to proper line etc complete. |
| 60 | Item No.19:-Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding,preparing the surfaces.(excluding the primer coat.) etc. complete. |
| 61 | Item No.20:-Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to old plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. |
| 62 | Sub Estimate No.4 - Pumping MachineryItem No. 1 - Providing, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon / fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer\"s design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump. Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) up to 8 stages. 7.5 BHP PUMPSET |
| 63 | Item No. 2 - Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed. |
| 64 | Item No. 3 - Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380-440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. |
| 65 | Item No.4 - Providing , installing & commissioning main control pannel boardincluding V.meter & A. meter of suitable range single phase prevention 8 Nos. of phase indicater lamps with colour glass of 230 V rotary switch over load capacitor suitable for < 7.5 HP pump etc.complete. |
| 66 | Item No.5 - Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. Pipe. Pressure gauge shall be installed as directed, with tapping on rising main. |
| 67 | Item No. 6 - Providing tools for pumping. |
| 68 | Item No. 7 - Main wiring work from M. S. E. B. cut out to the panel board 4 core x 459 mm 1100 grade with I. S. I. Mark standard / Aluminum armored cable (94.1 p.36) |
| 69 | Item No. 8 - Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP |
| 70 | Sub Estimate No.5 - Solar Pumping MachineryItem No. 1 :- Supplying, installing, testing and commissioning of 10 HP capacity AC/DC Solar water pump (SPV pump), comprising of min. 10 KWp capacity multi crystalline SPV modules mounted on GI Structure with necessary hardware with controller, suitable size HDPE delivery water pipe line up to 60 mtr length inside or above water tank/ borewell with necessary control valves and necessary power supply cable of appropriate size complete with 5 years on site performance warrantee. Specification no. ESD-SWPS 10 BHP Solar pump |
| 71 | Item No. 2 :- Providing and erecting 1.5 metre high wire fencing with seven rows of barbed wire supported on M.S.Angles ( 50mm x 50mm x 6mm) at 2.5 Metres, Center to center including excavating pits for foundqtion, fixing post in cement cocnrete 1:4:8 of size 45 x 45 x 45 cm fastening the wire and painting the M.S.Angles with one coat of red lead primer and two coats of painting etc.complete. |
| 72 | Item No. 3 :- Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt |
| 73 | Sub Estimate No.6 - Rising Main Item No. 1 - Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. Note:- H.D.P.E. Pipes shall be as per latest IS Specifications Also HDPE pipes upto 110 mm Dia shall be in coil form110 mm Dia HDPE Pipe 8 Kg/sqcm |
| 74 | Item No. 2 - Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. Sluice valves 100 mm Dia.complete |
| 75 | Item No. 3 - Providing & supplying ISI mark CI D/F reflux valve (Non- returnvalve)offollowingdiaincludingalltaxes(central andlocal), railwayfreight, inspectionchargesunloading from railway wagon, loading into truck, transportation upto department stores/site, unloading, stacking etc. complete. reflux valves as per I.S.5312 part I (1984). Reflux valves 100 mm Dia |
| 76 | Item No. 4 - Providing, erecting, connecting double flanged short body pattern tye manually operated Butterfly Valve having body, disc and end cover in graded cast iron to IS 210 Gr. CF 200generallyconforminginBS5155,Syntheticrubber faced ring secured on disc by retaining ring with stainless steelscrewstubshaftofstainlesssteelridinginTeflon bearings excluding C.C. foundation/ structural steel support confirming to IS 3095-1991. Sluice valves 100 mm Dia. for Washout |
| 77 | Item No. 5 - ProvidingandsupplyingAirvalvesasperIS-10845and MJP’s standard specifications of approved mark and quality offollowingdiametersincludingalltaxes (Central andlocal),railwayfright,inspectionchargesunloading fromrailwaywagons,loadingintotruck,transportation upto departmental stores/ site, unloading and stacking etc. complete. Air valves 25 mm Dia |
| 78 | Item No. 6 - Excavation for foundation/ pipe trenches in earth, soils of all types, sand gravel and soft murum, including removing the excavated material upto a distance of 50 meters & lifts as below, stacking & spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (EARTH SOIL) |
| 79 | Item No. 7 - Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back- filling, etc. complete. (HARD MURRUM) |
| 80 | Item No. 8 - Excavation for foundation/ pipe trenches in soft rock and oldcementandlimemasonryfoundationasphaltroad including removing the excavated material upto a distance of50Mbeyond areaandliftsasbelow,stackingas directed by Engineer-in-charges, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (SOFT ROCK) |
| 81 | Item No. 9 - Excavationforfoundation/pipetrenchesin hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting includingtrimmingandlevellingthebed, removing the excavated material upto a distanceof50metresbeyondtheareaand lifts as below, stacking as directed by Engineer-in-charge,normaldewatering, excludingbackfilling,etc.completebyall means. (Bd-A-6/259 (HARD ROCK) |
| 82 | Item No. 10 - Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers including watering and compaction complete. |
| 83 | Item No. 11 - Lowering, Laying and Jointing H. D. P. E./ M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. 110 mm Dia HDPE Pipe 8 Kg/sqcm |
| 84 | Item No. 12 - Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including nut bolts and givingsatisfactoryhydraulictestingetc.complete.Sluice valves 100 mm Dia. Sluice valves 100 mm Dia. |
| 85 | Item No. 13 - Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete. Reflux valves 100 mm Dia |
| 86 | Item No. 14 - Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) Sluice valves 100 mm Dia. for Washout |
| 87 | Item No. 15 - Lowering, Layingand fixing in proper alignment and position all types of C.I. Air valves as directed by Engineer in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc complete. Air valves 25 mm Dia- Single Bash |
| 88 | Item No. 16 - Providingandfixinginpositionairvalveshaftincluding providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providingPCCblockofM-150concrete150mmthick aroundtheairvalveteeincludingencasingofvertical shaft in PCC M-150 as shown in type design together with providingandmakingflangedjointswhereverrequired and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.) |
| 89 | Item No. 17 - ProvidingandlayinginsitufollowinggradesofC.C.of trap/granite/quartzite/gneiss metal for foundation and bedding including dewatering, form work, compacting and curing, finishing etc. complete. |
| 90 | Item No. 18 - ProvidingandconstructingB.B.masonryvalvechamber with 15 cm thick 1:3:6 proportion PCC bedding, including excavation, B.B. masonry in C.M. 1:5proportion 12 mm thickcementplasterincm1:4proportiononbothsides with providing and fixing C.I. manhole frame and cover in RCC1:2:4copingorcmthickslabetc.completeas directed by Engineer-in-charge. |
| 91 | Item No. 19 - Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15 cm layers with all leadsand lifts including consolidation, surcharging, etc. complete |
| 92 | Item No. 20 - Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 110 mm Dia HDPE Pipe 8 Kg/sqcm |
| 93 | Item No. 21 - Giving satisfactory hydraulic testing of following C.I. D / F Reflex valves, Butterfly valves and Sluice valves. Sluice valves 100 mm Dia. |
| 94 | Reflux valves 100 mm Dia |
| 95 | Sluice valves 100 mm Dia. for Washout |
| 96 | Sub Estimate No.7 - Pressure Filter Item No. 1 - Pressure Filter with details attached here with capacity 50Cum/hr. As per quotation received from Aquasoft Kolhapur |
| 97 | Sub Estimate No.8 - RCC ESR 80,000 Ltr Staging height 7m Item No. 1 :- Designing (aesthetically), and constructingRCCelevatedservice reservoirsoffollowingcapacitywith RCCstagingconsistingofcolumns, internalandexternalbracingsspaced verticallynotmore than4.5 metres centre to centre for ESR having capacityupto500cumandnotmore than 6 m c/c for ESRs having capacity above 500 Cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compoundtotheinsidefaceofthe containerincludingrefillingdisposing off the surplus stuff within a lead of 50 metres, all labour and material charges including lowering, laying, erecting, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypassarrangements asper departmental design, providing andfixingaccessoriessuchasM.S. ladder, C.I. manhole frame and covers, waterlevelindicators,lightening conductor, G.I. pipe railing around walk way and top slab, providing spiral stair casefromgroundleveltorooflevel, M.S. grill gate of 2 M height with locking arrangementofapproveddesign,B.B. masonry chambers for all valves, ventilatingshafts,providingand applying three coats of cement paint to the structure including roof slab, epoxy painting to internal surface and anti- termite treatment for underground parts ofthestructureandgivingsatisfactory watertightnesstestasperI.S.code. The job to include painting the name of theschemeandotherdetailsonthe reservoir as per the directions of Engineer-in-Charge. |
| 98 | Item No. 2-Providing and casting in situ C.C. of trap / granite / gneiss metal of approved quality for P.C.C. works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, from work, compaction, finishing the formed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary of roughening if special finish is to be provided and curing etc. complete.( Excluding Reinforcement.) M:150 |
| 99 | Item No. 3 :- Providing D.I. pipes (push on joints pressure pipes of D. I. of following class and diameters confirming to the I. S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality ) excluding GST levied by GOI & GOM in all respect including Third party inspection charges of TPI Agency approved by MJP including Transit insurance, Railway Freight Unloading from railway wagon, Loading into Truck, Transportation to epartmental store, unloading, stacking etc. completed as directed by Engineer in charges (IS 1536/2001 for pipes and IS 158/1969 and IS 12820/1989 or latest edition/ revision with amendments for Rubber Gaskets. DI 150 mm Double flanged |
| 100 | Item No. 4 -Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete 150mm sluice valves - PN - 1 without bypass arrangement |
| 101 | Item No. 5 -Providing and supplying ISI standard D.I.specials & fitting with sealing rubber cascade of SBR complete with cast iron follower gland and MS nut bolts coated or otherwise protected from rusting and suitable for DI pipes inlcuding cost of labour, Materials, and transportation to stores/site, loading and unloading excluding GST levied by GOI and GOM in all respect, Complete as per IS 9523 for all types of specials, bends, tees etc. 9(80 to 300 mm dia) |
| 102 | Sub Estimate No. 9 - Distribution System Item No. 1 - Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i.e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. Note:- H.D.P.E. Pipes shall be as per latest IS Specifications Also HDPE pipes upto 110 mm Dia shall be in coil form . 63 mm dia HDPE PN 8 Pipes |
| 103 | 75 mm dia HDPE PN 8 Pipes |
| 104 | 90 mm dia HDPE PN 8 Pipes |
| 105 | 110 mm dia HDPE PN 8 Pipes |
| 106 | 125 mm dia HDPE PN 8 Pipes |
| 107 | 140 mm dia HDPE PN 8 Pipes |
| 108 | Item No. 2 - Specials for HDPE pipes.5% cost of the item No 1. |
| 109 | Item No. 3 - Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. Sluice valves 65 mm Dia |
| 110 | Sluice valves 80 mm Dia |
| 111 | Sluice valves 100 mm Dia |
| 112 | Item No. 4 - Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. EARTHSOIL |
| 113 | Item No. 5 - Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. HMB |
| 114 | Item No. 6 - Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. Soft Rock |
| 115 | Item No. 7 - Excavation for foundation / pipe trenches in hard rock by chiselling, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete. Hard Rock |
| 116 | Item No. 8 - Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. |
| 117 | Item No. 9 - Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. 63 mm dia HDPE PN 8 Pipes |
| 118 | 75 mm dia HDPE PN 8 Pipes |
| 119 | 90 mm dia HDPE PN 8 Pipes |
| 120 | 110 mm dia HDPE PN 8 Pipes |
| 121 | 125 mm dia HDPE PN 8 Pipes |
| 122 | 140 mm dia HDPE PN 8 Pipes |
| 123 | Item No. 10 - Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. Sluice Valve 65 mm Dia |
| 124 | Sluice Valve 80 mm Dia |
| 125 | Sluice Valve 100 mm Dia |
| 126 | Item No. 11 - Providing and laying in situ Cement Concrete of trap/ granite / quartzite /gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering,form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 127 | Item No. 12 - Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. |
| 128 | Item No. 13 - Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15cmlayerswithallleadsandliftsincluding consolidation, surcharging, etc. complete |
| 129 | Item No. 14 - Hydraulic testing of H. D. P. E./ M. D. P. E./D.I. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 63 mm dia HDPE PN 8 Pipes |
| 130 | 75 mm dia HDPE PN 8 Pipes |
| 131 | 90 mm dia HDPE PN 8 Pipes |
| 132 | 110 mm dia HDPE PN 8 Pipes |
| 133 | 125 mm dia HDPE PN 8 Pipes |
| 134 | 140 mm dia HDPE PN 8 Pipes |
| 135 | Item No. 15 - Providingandfixingboarddisplayinginformation, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangularshapeof1.20mx0.90msize made out 18 gauge (1.25 mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stoveenamelonbacksideandborder/messages /symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x35 x3 mm frame with properly cross braced M.S.angles of size 35 mm x 35 mm x 3 mm duly painted including Two M.S.angle iron posts of size 65 mmx 65 mmx 6 mm, 3.65mlongpaintedwithalternateblackandwhite bandsof25cmwidthincludingallfixturesetc.and fixing the boards in 1:4:8 concrete block of size 60 cm x60cmx75cmincluding,excavation,refilling, transportation,andlabouretccomplete.Spec. Number As directed by Engineer in Charge MORTH 801 |
| 136 | Item No. 16 - Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour ,UPVC/MDPE Pipe of required lengthwith or without Road crossing as described below, including cost of specials likeaddle/Clamp Saddle of suitable material, and diameter suitablefor Distribution main, 15mm/20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitablematerialand sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in alltypes of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineerin charge.B)Household Connection without watermeter (With Integrated Saddle &compression Specials) For HDPE/PVCpipe (With Road Crossing)For 15 mm Service connection |
| 137 | (Without Road Crossing)For 15 mm Service connection |
| 138 | Providinq andLayinq insituCement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and beddinq including baidng outwater,form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)b) In PCC M-150Road Restoration WorkConcrete Road |
| 139 | Sub Estimate No.10 - Electrification Charges Item No. 1 - Providing & streching transmission line & making Additional electric load connection to Head works, including all charges as per MSEB rule |
| 140 | Sub Estimate No.11 - Trial Run |
| 141 | DEVGAONExcavation in general in soft material comprising of soft soil, soft murum, sand,hard murum with boulders in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, Supply Well, etc. for lift 0 to 1.5M and lead of 150 M including barricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-incharge, etc. complete excluding refilling.Lift 0.00 M to 1.50 m |
| 142 | Lift 1.50 M to 3.00 m |
| 143 | Lift 3.00 M to 4.50 m |
| 144 | Lift 4.50 M to 6.00 m |
| 145 | Excavation in general in hard material comprising of soft rock, hard rock, Manjara rock, etc. by blasting / controlled blasting, chiselling as required in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, Supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including barricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-incharge, excluding refilling.Lift 6.00 M to 7.50 m |
| 146 | Lift 7.50 M to 9.00 m |
| 147 | Lift 9.00 M to 10.50 m |
| 148 | Providing and laying in situ Cement concrete in proporation .... of trap metal for foundation and bedding, including balling out water manually, formwork, compacting and curing etc. complete.P.C.C 1:2:4 ( M-15 ) |
| 149 | Providing & costing inconstructingin situ. C.C of trap granite/ quartzite / gneiss/ metal of approved quality of R.C.C. work as per detailed drawing & design or as directed by Engg. in charge including dewatering , ceterind from work,compacting, finishingthe formed surface withC.M. 1:3 of sufficient minimum thickness to give a smooth & even surface wherever necessary or roughening if spetial finish is to be provided & curing etc. complete. ( By weight batching & mix design for M-250 & M-300 only use of L&T, ACC Ambuja, Birla Gold, Manikgad, Rajashree etc. cement is permitted excluding M.S or Tor reinforcement in R.C.C. M-250grade.1) R.C.C. M-250 for Beam |
| 150 | 2) R.C.C. M-250 for walkway slab |
| 151 | 3) R.C.C. M-250 for vertical wall |
| 152 | Providing & fixing in position steel bar reinforcement of various diameters for R.C.C. Pipes,caps,footing, foundation, slab, beams, columns, canopies, staircase, newels,chajjas, lintels,pardies,coping,fine arches etc. as per detailed designs, drawing & schedule s including cutting, bending, hooking the bars,bindingwith wires or tack welding & supporting as required etc. complete (including cost of binding wire). Corrosion Resistant Steel |
| 153 | Providing & laying weep holes of 80 mmAC/PVC pipe as per drawing for abutment returns, return wallsetc. complete. |
| 154 | Dewatering the excavatyed trenches and pools of water by using pumps and other devices including disposing of the water to safe distance as directed by Engineer-in-Charge (including cost of machinerylabour fuel )etc complete. |
| 155 | Providing uncoursed rubble masonry of t rap / granite / quartzite /gneiss stones in cement mor tar 1:6 in foundation and plinth of innerwalls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and water ing etc.complete. |
| 156 | Providing internal cement plaster 20mm. thick in two coats in cement mor tar 1:3 wi thout neeru finish, to concrete, br ick sur face, in all posi t ions including scaffolding and cur ing etc. complete. |
| 157 | Reffiling the trenches with approved excavated material from foundation in 15cm to 20cm layers including watering and compaction etc. complete. |
| 158 | Providing and fixing in position C.I. dapuri steps or 22 mm dia. M.S. bar step with proper anchorage, etc. and providing and applying 3 coats of anticorrosive paint, etc complete as directed by Engineer- in-charge. |
| 159 | Providing structural steel work in rolled sections like joists, channels, angles,tees, etc. as per detailed designs and drawings including fixing in position without connecting plates, braces, etc. and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, etc. complete. (Bd-C-2/275) |
| 160 | Switch Room Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259) |
| 161 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) |
| 162 | Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) |
| 163 | Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) |
| 164 | roviding uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete |
| 165 | Providing flush grooved pointing with cement mortar 1:3 for stone masonry work including scaffolding and curing etc. complete. |
| 166 | Filling in plinth and floors / trenches with contractor\"s murum for bedding in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-11/263) |
| 167 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC M200 works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 168 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 169 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) |
| 170 | Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) |
| 171 | roviding and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 172 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC M200 works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 173 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC M200 works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 174 | Providing and fixing in position steel bar reinforcement of various diamenters for RCC piles, caps, footing, foundation, slabs, beams, columns, canopies, staircases, newels,chjjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking he bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) |
| 175 | Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 176 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 177 | Providing and laying cement concrete flooring 50mm thick with cement concrete M-25 laid to proper line etc complete. |
| 178 | Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding,preparing the surfaces.(excluding the primer coat.) etc. complete |
| 179 | Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to old plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. |
| 180 | Providing, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply, with cable guard, thrust carbon / fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer\"s design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump.Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) up to 8 stages.12.5 BHP PUMPSET |
| 181 | Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed.3 core 10sqmm |
| 182 | Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. |
| 183 | Providing , installing & commissioning main control pannel boardincluding V.meter & A. meter of suitable range single phase prevention 8 Nos. of phase indicater lamps with colour glass of 230 V rotary switch over load capacitor suitable for < 7.5 HP pump etc.complete. (Market rate) |
| 184 | Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. Pipe. Pressure gauge shall be installed as directed, with tapping on rising main. Pressure gauge (100 mm dia) |
| 185 | Providing tools for pumping. |
| 186 | Supplying and erecting, XLPE / PVC insulated,armoured cable 1100 V grade with ISI mark Fourcore, solid / stranded aluminium conductor with 6mm thick 25 mm width M.S. spacer with G.I. Earthwire 6 sq mm, complete erected on wall / on polewith 25 X 3 mm M.S. clamps or in provided trench inan approved manner |
| 187 | Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP |
| 188 | Rising Main Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete.250 mm Dia HDPE Pipe 8 Kg/sqcm |
| 189 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete..Sluice valves 250 mm Dia. |
| 190 | Providing & supplying ISI mark CI D/F reflux valve (Non- returnvalve)offollowingdiaincludingalltaxes(central andlocal), railwayfreight, inspectionchargesunloading from railway wagon, loading into truck, transportation upto department stores/site, unloading, stacking etc. complete. reflux valves as per I.S.5312 part I (1984)Reflux valves 250 mm Dia |
| 191 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete...Sluice valves 250 mm Dia. for Washout |
| 192 | ProvidingandsupplyingAirvalvesasperIS-10845and MJP’s standard specifications of approved mark and quality offollowingdiametersincludingalltaxes (Central andlocal),railwayfright,inspectionchargesunloading fromrailwaywagons,loadingintotruck,transportation upto departmental stores/ site, unloading and stacking etc. complete.Air valves 50mm Dia |
| 193 | Excavation for foundation/ pipe trenches in earth, soils of all types, sand gravel and soft murum, including removing the excavated material upto a distance of 50 meters & lifts as below, stacking & spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.(EARTH SOIL) |
| 194 | Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back- filling, etc. complete.(HARD MURRUM) |
| 195 | Excavation for foundation/ pipe trenches in soft rock and oldcementandlimemasonryfoundationasphaltroad including removing the excavated material upto a distance of50Mbeyond areaandliftsasbelow,stackingas directed by Engineer-in-charges, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Soft Rock |
| 196 | Excavationforfoundation/pipetrenchesin hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting includingtrimmingandlevellingthebed, removing the excavated material upto a distanceof50metresbeyondtheareaand lifts as below, stacking as directed by Engineer-in-charge,normaldewatering, excludingbackfilling,etc.completebyall means. (Bd-A-6/259)Hard Rock |
| 197 | Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers including watering and compaction complete. |
| 198 | Lowering, Laying and Jointing H. D. P. E./ M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II250mm Dia HDPE Pipe 8 Kg/sqcm |
| 199 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) SLUICE valves 250 mm Dia |
| 200 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves)Reflux valves 250 mm Dia |
| 201 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) Sluice valves 250 mm Dia. for Washout |
| 202 | Lowering, Layingand fixing in proper alignment and position all types of C.I. Air valves as directed by Engineer in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc complete. Air valves 50 mm Dia- Single Bash |
| 203 | Providingandfixinginpositionairvalveshaftincluding providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providingPCCblockofM-150concrete150mmthick aroundtheairvalveteeincludingencasingofvertical shaft in PCC M-150 as shown in type design together with providingandmakingflangedjointswhereverrequired and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.)upto 150 mm on Murum & harder strata |
| 204 | ProvidingandlayinginsitufollowinggradesofC.C.of trap/granite/quartzite/gneiss metal for foundation and bedding including dewatering, form work, compacting and curing, finishing etc. complete.b) 1:2:4 (M-150) grade for encasing |
| 205 | ProvidingandconstructingB.B.masonryvalvechamber with 15 cm thick 1:3:6 proportion PCC bedding, including excavation, B.B. masonry in C.M. 1:5proportion 12 mm thickcementplasterincm1:4proportiononbothsides with providing and fixing C.I. manhole frame and cover in RCC1:2:4copingorcmthickslabetc.completeas directed by Engineer-in-charge.Size 0.90 x 0.60 x 1.20 |
| 206 | Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15 cm layers with all leadsand lifts including consolidation, surcharging, etc. complete |
| 207 | Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.250 mm Dia HDPE Pipe 8 Kg/sqcm |
| 208 | Giving satisfactory hydraulic testing of following C.I. D / F Reflex valves, Butterfly valves and Sluice valves.Sluice valves 2520 mm Dia. |
| 209 | Reflux valves 250 mm Dia |
| 210 | Sluice valves 250 mm Dia. for Washout |
| 211 | RCC ESR ESR Capacity 2,00,000 LTR ST.HT-8 M |
| 212 | Providing and casting in situ C.C. of trap / granite / gneiss metal of approved quality for P.C.C. works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, from work, compaction, finishing the formed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary of roughening if special finish is to be provided and curing etc. complete.( Excluding Reinforcement.) M:150 |
| 213 | Providing D.I. pipes (push on joints pressure pipes of D. I. of following class and diameters confirming to the I. S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality ) excluding GST levied by GOI & GOM in all respect including Third party inspectioncharges of TPI Agency approved by MJP including Transit insurance, Railway Freight Unloading from railway wagon, Loading into Truck, Transportation to epartmental store, unloading, stacking etc. completed as directed by Engineer in charges (IS 1536/2001 for pipes and IS 158/1969 and IS 12820/1989 or latest edition/ revision with amendments for Rubber Gaskets. DI 200 MM Double flanged |
| 214 | DI 250 mm Double flanged |
| 215 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete 200 mm sluice valves - PN - 1 without bypass arrangement |
| 216 | 250 mm sluice valves - PN -1 |
| 217 | Providing and supplying ISI standard D.I.specials & fitting with sealing rubber cascade of SBR complete with cast iron follower gland and MS nut bolts coated or otherwise protected from rusting and suitable for DI pipes inlcuding cost of labour, Materials, and transportation to stores/site, loading and unloading excluding GST levied by GOI and GOM in all respect, Complete as per IS 9523 for all types of specials, bends, tees etc. 9(80 to 300 mm dia) |
| 218 | Distribution System Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i.e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete.63 mm dia HDPE PN 8 Pipes |
| 219 | 75 mm dia HDPE PN 8 Pipes |
| 220 | 90 mm dia HDPE PN 8 Pipes |
| 221 | 110 mm dia HDPE PN 8 Pipes |
| 222 | 125 mm dia HDPE PN 8 Pipes |
| 223 | 140 mm dia HDPE PN 8 Pipes |
| 224 | 180 mm dia HDPE PN 8 Pipes |
| 225 | Providing HDPESpecialsasperstandard specifications&directionofinchargeEngineer.(5%of Item No.2) |
| 226 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete Sluice valves 65 mm Dia |
| 227 | Sluice valves 100mm Dia |
| 228 | Sluice valves 150 mm Dia |
| 229 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259)(EARTH SOIL) |
| 230 | Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-3/259) (Hard Murrum) |
| 231 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259)(Soft Rock) |
| 232 | Excavation in hard rock masses mechanically, including lift upto 1.5 M including trimming and levelling the bedremoving the excavated material upto a distance of 50 metres beyond the area and lift as below stacking by as directed by Engineer-in-charge, normal dewatering excluding backfilling, etc. complete. (Hard rock) |
| 233 | Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263) |
| 234 | Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. 63 mm dia HDPE PN 8 Pipes |
| 235 | 75 mm dia HDPE PN 8 Pipes |
| 236 | 90 mm dia HDPE PN 8 Pipes |
| 237 | 110 mm dia HDPE PN 8 Pipes |
| 238 | 125 mm dia HDPE PN 8 Pipes |
| 239 | 140 mm dia HDPE PN 8 Pipes |
| 240 | 180 mm dia HDPE PN 8 Pipes |
| 241 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)Sluice Valve 65 mm Dia |
| 242 | Sluice Valve 100 mm Dia |
| 243 | Sluice Valve 150 mm Dia |
| 244 | Providing and laying in situ Cement Concrete of trap/ granite / quartzite /gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering,form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)a) 1:2:4 (M-150) grade for Thrust Blocks b) 1:2:4 (M-150) grade for encasing |
| 245 | Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. As above of 90 x 60 cm internal size and depth upto 1.2 M with precast R.C.C slab cover. |
| 246 | Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15cmlayerswithallleadsandliftsincluding consolidation, surcharging, etc. complete |
| 247 | Hydraulic testing of H. D. P. E./ M. D. P. E./D.I. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 63 mm dia HDPE PN 8 Pipes |
| 248 | 75 mm dia HDPE PN 8 Pipes |
| 249 | 90 mm dia HDPE PN 8 Pipes |
| 250 | 110 mm dia HDPE PN 8 Pipes |
| 251 | 125 mm dia HDPE PN 8 Pipes |
| 252 | 140 mm dia HDPE PN 8 Pipes |
| 253 | 180mm dia HDPE PN 8 Pipes |
| 254 | Providingandfixingboarddisplayinginformation, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangularshapeof1.20mx0.90msize made out 18 gauge (1.25 mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stoveenamelonbacksideandborder/messages /symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x35 x3 mm frame with properly cross braced M.S.angles of size 35 mm x 35 mm x 3 mm duly painted including Two M.S.angle iron posts of size 65 mmx 65 mmx 6 mm, 3.65mlongpaintedwithalternateblackandwhite bandsof25cmwidthincludingallfixturesetc.and fixing the boards in 1:4:8 concrete block of size 60 cm x60cmx75cmincluding,excavation,refilling, transportation,andlabouretccomplete.Spec. Number As directed by Engineer in Charge MORTH 801 |
| 255 | PRESSURE FILTER- 20 CUM/HR |
| 256 | Misc Works-MSEB PROVISION |
| 257 | Trial Run(3months) |
| 258 | MADAKEPADA Switch Room Item no.1 Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259) |
| 259 | Item no.2 Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) |
| 260 | Item no.3 Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) |
| 261 | Item no.4 Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) |
| 262 | Item no.5 Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete |
| 263 | Item no.6 Providing flush grooved pointing with cement mortar 1:3 for stone masonry work including scaffolding and curing etc. complete. |
| 264 | Item no.7 Filling in plinth and floors / trenches with contractor\"s murum for bedding in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-11/263) |
| 265 | Item no.8 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 266 | Item no.9 Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 267 | Item no.10 Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) |
| 268 | Item no.11 Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) |
| 269 | Item no.12 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 270 | Item no.13 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 271 | Item no.14 Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 272 | Item no.15 Providing and fixing in position steel bar reinforcement of various diamenters for RCC piles, caps, footing, foundation, slabs, beams, columns, canopies, staircases, newels,chjjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking he bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) |
| 273 | Item no.16 Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 274 | Item no.17 Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 275 | Item no.18 Providing and laying cement concrete flooring 50 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction filling joints, marking lines to give the appearance of tiles of 30cm x 30cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete.with Crushed sand VSI Grade |
| 276 | Item no.19 Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete. |
| 277 | Item no.20 Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to old plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. |
| 278 | Pumping m/cProviding, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 bPh, 50 Hz A.C. Supply, with cable guard, thrust carbon / fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer\"s design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump. Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) up to 8 stages7.5BHP Pumpset |
| 279 | Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed.3 core 10sqmm |
| 280 | Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380-440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser < 12.5 BHP or upto 20 BHP |
| 281 | Providing , installing & commissioning main control pannel boardincluding V.meter & A. meter of suitable range single phase prevention 8 Nos. of phase indicater lamps with colour glass of 230 V rotary switch over load capacitor suitable for >12.5 BHP or upto 20 BHP. (Market rate) |
| 282 | Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. Pipe. Pressure gauge shall be installed as directed, with tapping on rising main. Pressure gauge (100 mm dia) |
| 283 | Providing tools for pumping. |
| 284 | Main wiring work from M. S. E. B. cut out to the panel board 4 core x 459 mm 1100 grade with I. S. I. Mark standard / Aluminum armored cable (94.1 p.36) |
| 285 | Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP |
| 286 | SOLAR PUMPING MACHINERY - Supplying, installing, testing and commissioning of 10 HP capacity AC/DC Solar water pump (SPV pump),comprising of min. 10 KWp capacity multi crystalline SPV modules mounted on GI Structure with necessary hardware with controller, suitable size HDPE delivery water pipe line up to 60 mtr length inside or above water tank/ borewell with necessary control valves and necessary power supply cable of appropriate size complete with 5 years on site performance warrantee. Specification no. ESD-SWPS 10 BHP PUMP |
| 287 | Providing and erecting 1.5 metre high wire fencing with seven rows of barbed wire supported on M.S.Angles ( 50mm x 50mm x 6mm) at 2.5 Metres, Center to center including excavating pits for foundqtion, fixing post in cement cocnrete 1:4:8 of size 45 x 45 x 45 cm fastening the wire and painting the M.S.Angles with one coat of red lead primer and two coats of painting etc.complete. |
| 288 | Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt |
| 289 | RCC ESR 15000 LTRS ST.HT.14 M. |
| 290 | Providing and casting in situ C.C. of trap / granite / gneiss metal of approved quality for P.C.C. works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, from work, compaction, finishing the formed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary of roughening if special finish is to be provided and curing etc. complete.( Excluding Reinforcement.) M:150 |
| 291 | Providing D.I. pipes (push on joints pressure pipes of D. I. of following class and diameters confirming to the I. S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality ) excluding GST levied by GOI & GOM in all respect including Third party inspectioncharges of TPI Agency approved by MJP including Transit insurance, Railway Freight Unloading from railway wagon, Loading into Truck, Transportation to epartmental store, unloading, stacking etc. completed as directed by Engineer in charges (IS 1536/2001 for pipes and IS 158/1969 and IS 12820/1989 or latest edition/ revision with amendments for Rubber Gaskets. DI 100mm Double flanged |
| 292 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete 100mm sluice valves - PN - 1 without bypass arrangement |
| 293 | Providing and supplying ISI standard D.I.specials & fitting with sealing rubber cascade of SBR complete with cast iron follower gland and MS nut bolts coated or otherwise protected from rusting and suitable for DI pipes inlcuding cost of labour, Materials, and transportation to stores/site, loading and unloading excluding GST levied by GOI and GOM in all respect, Complete as per IS 9523 for all types of specials, bends, tees etc. 9(80 to 300 mm dia) |
| 294 | Rising Main Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. 90 mm Dia HDPE Pipe 10 Kg/sqcm |
| 295 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete..Sluice valves 80 mm Dia. |
| 296 | Providing & supplying ISI mark CI D/F reflux valve (Non- returnvalve)offollowingdiaincludingalltaxes(central andlocal), railwayfreight, inspectionchargesunloading from railway wagon, loading into truck, transportation upto department stores/site, unloading, stacking etc. complete. reflux valves as per I.S.5312 part I (1984) Reflux valves 80 mm Dia |
| 297 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete..Sluice valves 80 mm Dia. FOR WASHOUT |
| 298 | ProvidingandsupplyingAirvalvesasperIS-10845and MJP’s standard specifications of approved mark and quality offollowingdiametersincludingalltaxes (Central andlocal),railwayfright,inspectionchargesunloading fromrailwaywagons,loadingintotruck,transportation upto departmental stores/ site, unloading and stacking etc. complete.Air valves 25 mm Dia |
| 299 | Excavation for foundation/ pipe trenches in earth, soils of all types, sand gravel and soft murum, including removing the excavated material upto a distance of 50 meters & lifts as below, stacking & spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.(EARTH SOIL) |
| 300 | Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back- filling, etc. complete.(HARD MURRUM) |
| 301 | Excavation for foundation/ pipe trenches in soft rock and oldcementandlimemasonryfoundationasphaltroad including removing the excavated material upto a distance of50Mbeyond areaandliftsasbelow,stackingas directed by Engineer-in-charges, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Soft Rock |
| 302 | Excavationforfoundation/pipetrenchesin hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting includingtrimmingandlevellingthebed, removing the excavated material upto a distanceof50metresbeyondtheareaand lifts as below, stacking as directed by Engineer-in-charge,normaldewatering, excludingbackfilling,etc.completebyall means. (Bd-A-6/259)Hard Rock |
| 303 | Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers including watering and compaction complete. |
| 304 | Lowering, Laying and Jointing H. D. P. E./ M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II90 mm Dia HDPE Pipe 10 Kg/sqcm |
| 305 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) SLUICE valves 80mm Dia |
| 306 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) Sluice valves 80 mm Dia. for Washout |
| 307 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) Reflux valves 80 mm Dia. |
| 308 | Lowering, Layingand fixing in proper alignment and position all types of C.I. Air valves as directed by Engineer in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc complete. Air valves 25 mm Dia- Single Bash |
| 309 | Providingandfixinginpositionairvalveshaftincluding providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providingPCCblockofM-150concrete150mmthick aroundtheairvalveteeincludingencasingofvertical shaft in PCC M-150 as shown in type design together with providingandmakingflangedjointswhereverrequired and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.)upto 150 mm on Murum & harder strata |
| 310 | ProvidingandlayinginsitufollowinggradesofC.C.of trap/granite/quartzite/gneiss metal for foundation and bedding including dewatering, form work, compacting and curing, finishing etc. complete.b) 1:2:4 (M-150) grade for encasing |
| 311 | ProvidingandconstructingB.B.masonryvalvechamber with 15 cm thick 1:3:6 proportion PCC bedding, including excavation, B.B. masonry in C.M. 1:5proportion 12 mm thickcementplasterincm1:4proportiononbothsides with providing and fixing C.I. manhole frame and cover in RCC1:2:4copingorcmthickslabetc.completeas directed by Engineer-in-charge.Size 0.90 x 0.60 x 1.20 |
| 312 | Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15 cm layers with all leadsand lifts including consolidation, surcharging, etc. complete |
| 313 | Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.110 mm Dia HDPE Pipe 8 Kg/sqcm |
| 314 | Giving satisfactory hydraulic testing of following C.I. D / F Reflex valves, Butterfly valves and Sluice valves.Sluice valves 80 mm Dia. |
| 315 | Sluice valves 80mm Dia. for Washout |
| 316 | Reflux valves 80 mm Dia. t |
| 317 | Providinq andLayinq insituCement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and beddinq including baidng outwater,form work, compaction, curing, etc.complete. (Cement 5.90 bags / cum)b) In PCC M-150Road Restoration WorkConcrete Road |
| 318 | Pressure Filter - 10cum/hr |
| 319 | DISTRIBUTION SYSTEM Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i.e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete.63 mm dia HDPE PN 8 Pipes |
| 320 | 75 mm dia HDPE PN 8 Pipes |
| 321 | 90 mm dia HDPE PN 8 Pipes |
| 322 | Providing HDPESpecialsasperstandard specifications&directionofinchargeEngineer.(5%of Item No.2) |
| 323 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete Sluice valves 65 mm Dia |
| 324 | Sluice valves 80 mm Dia |
| 325 | Dismantling the R.C.C.Work 1:2:4 and sorting out the materials such as steel etc.as directed and stacking them within the specified lead as directed etc. complete. |
| 326 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259)(EARTH SOIL) |
| 327 | Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-3/259) (Hard Murrum) |
| 328 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259)(Soft Rock) |
| 329 | Excavation in hard rock masses mechanically, including lift upto 1.5 M including trimming and levelling the bedremoving the excavated material upto a distance of 50 metres beyond the area and lift as below stacking by as directed by Engineer-in-charge, normal dewatering excluding backfilling, etc. complete. (Hard rock) |
| 330 | Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263) |
| 331 | Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. 63 mm dia HDPE PN 8 Pipes |
| 332 | 75 mm dia HDPE PN 8 Pipes |
| 333 | 90 mm dia HDPE PN 8 Pipes |
| 334 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)Sluice Valve 65 mm Dia |
| 335 | Sluice Valve 80 mm Dia |
| 336 | Providing and laying in situ Cement Concrete of trap/ granite / quartzite /gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering,form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)a) 1:2:4 (M-150) grade for Thrust Blocks b) 1:2:4 (M-150) grade for encasing |
| 337 | Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. As above of 90 x 60 cm internal size and depth upto 1.2 M with precast R.C.C slab cover. |
| 338 | Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15cmlayerswithallleadsandliftsincluding consolidation, surcharging, etc. complete |
| 339 | Hydraulic testing of H. D. P. E./ M. D. P. E./D.I. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 63 mm dia HDPE PN 8 Pipes |
| 340 | 75 mm dia HDPE PN 8 Pipes |
| 341 | 90 mm dia HDPE PN 8Pipes |
| 342 | Providingandfixingboarddisplayinginformation, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangularshapeof1.20mx0.90msize made out 18 gauge (1.25 mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stoveenamelonbacksideandborder/messages /symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x35 x3 mm frame with properly cross braced M.S.angles of size 35 mm x 35 mm x 3 mm duly painted including Two M.S.angle iron posts of size 65 mmx 65 mmx 6 mm, 3.65mlongpaintedwithalternateblackandwhite bandsof25cmwidthincludingallfixturesetc.and fixing the boards in 1:4:8 concrete block of size 60 cm x60cmx75cmincluding,excavation,refilling, transportation,andlabouretccomplete.Spec. Number As directed by Engineer in Charge MORTH 801 |
| 343 | Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour ,UPVC/MDPE Pipe of required lengthwith or without Road crossing as described below, including cost of specials likeaddle/Clamp Saddle of suitable material, and diameter suitablefor Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitablematerialand sundry materials as perrequirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in alltypes of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineerin charge.B)Household Connection without watermeter (With Integrated Saddle &compression Specials) For HDPE/PVCpipe ( With Road Crossing)For 15 mmService Connections |
| 344 | (Without Road Crossing)For 15 mm Service connection |
| 345 | Miscellaneos work |
| 346 | Trial Run(3months) |
| 347 | KORAWALEDismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. |
| 348 | Excavation in general in soft material comprising of soft soil, soft murum, sand,hard murum with boulders in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, Supply Well, etc. for lift 0 to 1.5M and lead of 150 M including barricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-incharge, etc. complete excluding refilling.Lift 0.00 M to 1.50 m |
| 349 | Lift 1.50 M to 3.00 m |
| 350 | Lift 3.00 M to 4.50 m |
| 351 | Lift 4.50 M to 6.00 m |
| 352 | Item.no.2Excavation in general in hard material comprising of soft rock, hard rock, Manjara rock, etc. by blasting / controlled blasting, chiselling as required in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, Supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including barricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-incharge, excluding refilling.Lift 7.50 M to 9.00 m |
| 353 | Lift 9.00 M to 10.50 m |
| 354 | Providing and laying in situ Cement concrete in proporation .... of trap metal for foundation and bedding, including balling out water manually, formwork, compacting and curing etc. complete.P.C.C 1:2:4 ( M-15 ) |
| 355 | Providing & costing inconstructingin situ. C.C of trap granite/ quartzite / gneiss/ metal of approved quality of R.C.C. work as per detailed drawing & design or as directed by Engg. in charge including dewatering , ceterind from work,compacting, finishingthe formed surface withC.M. 1:3 of sufficient minimum thickness to give a smooth & even surface wherever necessary or roughening if spetial finish is to be provided & curing etc. complete. ( By weight batching & mix design for M-250 & M-300 only use of L&T, ACC Ambuja, Birla Gold, Manikgad, Rajashree etc. cement is permitted excluding M.S or Tor reinforcement in R.C.C. M-250grade.1) R.C.C. M-250 for Beam |
| 356 | 2) R.C.C. M-250 for walkway slab |
| 357 | 3) R.C.C. M-250 for vertical wall |
| 358 | Providing & fixing in position steel bar reinforcement of various diameters for R.C.C. Pipes,caps,footing, foundation, slab, beams, columns, canopies, staircase, newels,chajjas, lintels,pardies,coping,fine arches etc. as per detailed designs, drawing & schedule s including cutting, bending, hooking the bars,bindingwith wires or tack welding & supporting as required etc. complete (including cost of binding wire). Corrosion Resistant Steel |
| 359 | Providing & laying weep holes of 80 mmAC/PVC pipe as per drawing for abutment returns, return wallsetc. complete. |
| 360 | Dewatering the excavatyed trenches and pools of water by using pumps and other devices including disposing of the water to safe distance as directed by Engineer-in-Charge (including cost of machinerylabour fuel )etc complete. |
| 361 | Providing uncoursed rubble masonry of t rap / granite / quartzite /gneiss stones in cement mor tar 1:6 in foundation and plinth of innerwalls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and water ing etc.complete. |
| 362 | Providing internal cement plaster 20mm. thick in two coats in cement mor tar 1:3 without neeru finish, to concrete, br ick sur face, in all posi t ions including scaffolding and cur ing etc. complete. |
| 363 | Providing and fixing in position C.I. dapuri steps or 22 mm dia. M.S. bar step with proper anchorage, etc. and providing and applying 3 coats of anticorrosive paint, etc complete as directed by Engineer- in-charge. |
| 364 | Providing structural steel work in rolled sections like joists, channels, angles,tees, etc. as per detailed designs and drawings including fixing in position without connecting plates, braces, etc. and one coat of anticorrosive paint and over it two coats of oil painting of approved quality and shade, etc. complete. (Bd-C-2/275) |
| 365 | Switch Room 2.50 m to 2.50 mExcavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A- 1/259) |
| 366 | Excavation for foundation / pipe trenches in hard murum including removing the excavated material upto a distance of 50 M and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-2/259) |
| 367 | Providing dry trap/ granite/ quartzite/ gneiss, rubble stone soling in 15 cm to 20 cm thick layers including hand packing and compacting, etc. complete. (Bd-A-12/264) |
| 368 | Providing and laying in situ Cement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and bedding including bailing out water, form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum) |
| 369 | Providing uncoursed rubble masonry of trap / granite / quartzite / gneiss stones in cement mortar 1:6 in foundation and plinth of inner walls / in plinth of external walls including bailing out water manually , striking joints on un exposed faces and watering etc.complete |
| 370 | Providing flush grooved pointing with cement mortar 1:3 for stone masonry work including scaffolding and curing etc. complete. |
| 371 | Filling in plinth and floors / trenches with contractor\"s murum for bedding in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-11/263) |
| 372 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC M 200 works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 373 | Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete |
| 374 | Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear) |
| 375 | Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.) |
| 376 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC M 200 works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 377 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC M 200 works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 378 | Providing and casting in situ C.C. of trap / granite/ quartzite / gneiss metal of approved quality for RCC M 200 works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, form work, compaction, finishing the formed surfaces with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary or roughening if special finish is to be provided and curing, etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement) |
| 379 | Providing and fixing in position steel bar reinforcement of various diamenters for RCC piles, caps, footing, foundation, slabs, beams, columns, canopies, staircases, newels,chjjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules, including cutting, bending, hooking he bars, binding with wires or tack welding and supporting as required, etc. complete.(including cost of binding wire) |
| 380 | Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. |
| 381 | Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4 using waterproofing compound at 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. |
| 382 | Providing and laying cement concrete flooring 50 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction filling joints, marking lines to give the appearance of tiles of 30cm x 30cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete.with Crushed sand VSI Grade |
| 383 | Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding,preparing the surfaces.(excluding the primer coat.) etc. complete. |
| 384 | Providing and applying two coats of water proof cement paint of approved manufacture and of approved colour to old plastered surfaces including scaffolding if necessary, cleaning and preparing the surface, watering for two days etc. complete. |
| 385 | Pumping m/cProviding, erecting and giving test of submersible pump set conforming to IS 8034 and motor conforming to IS 9283, with water proof winding. Pump shall be suitable for various delivery head and discharge with stainless steel shaft. Motor suitable for working on 415 V ± 10%, 3 bPh, 50 Hz A.C. Supply, with cable guard, thrust carbon / fiber bearing to withstand entire hydraulic thrust. The pump set shall be suitable for direct coupling, with suitable suction strainer. Pump should have suitable discharge out let as per manufacturer\"s design. Antithrust stream lined non return valve shall be provided with the pump. 3 m submersible copper conductor cable in single / double run and 2 pairs of suitable size erection clamp 10 mm thick shall be provided with each pump. Submersible Pump 150 mm dia (with Bronze / Stainless steel (CF8M) Impeller) up to 8 stages10BHP Pumpset |
| 386 | Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed.3 core 10sqmm |
| 387 | Supplying and erecting Fully Automatic Star Delta starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil, over load element, and ON OFF push buttons, with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser. |
| 388 | Providing , installing & commissioning main control pannel boardincluding V.meter & A. meter of suitable range single phase prevention 8 Nos. of phase indicater lamps with colour glass of 230 V rotary switch over load capacitor suitable for >12.5 BHP or upto 20 BHP. (Market rate) |
| 389 | Providing, erecting Pressure gauge of required range complete with syphon tube, isolating cock suitable for 12 mm dia G.I. Pipe. Pressure gauge shall be installed as directed, with tapping on rising main. Pressure gauge (100 mm dia) |
| 390 | Providing tools for pumping. |
| 391 | Supplying and erecting, XLPE / PVC insulated, armoured cable 1100 V grade with ISI mark Four core, solid / stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer with G.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner. |
| 392 | Providing pipe type earthing with 40mm. dia. G.l. pipe or 20 mm dia. G.l. Rod complete with all materials as per specification no. EA-EP |
| 393 | RCC ESR 100000 LTRS |
| 394 | Providing and casting in situ C.C. of trap / granite / gneiss metal of approved quality for P.C.C. works as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, from work, compaction, finishing the formed surface with C.M. 1:3 of sufficient minimum thickness to give a smooth and even surface wherever necessary of roughening if special finish is to be provided and curing etc. complete.( Excluding Reinforcement.) M:150 |
| 395 | Providing D.I. pipes (push on joints pressure pipes of D. I. of following class and diameters confirming to the I. S. specification inclusive cost of jointing materials (Rubber gasket of EPDM Quality ) excluding GST levied by GOI & GOM in all respect including Third party inspectioncharges of TPI Agency approved by MJP including Transit insurance, Railway Freight Unloading from railway wagon, Loading into Truck, Transportation to epartmental store, unloading, stacking etc. completed as directed by Engineer in charges (IS 1536/2001 for pipes and IS 158/1969 and IS 12820/1989 or latest edition/ revision with amendments for Rubber Gaskets. DI 150mm Double flanged |
| 396 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete 100mm sluice valves - PN - 1 without bypass arrangement |
| 397 | 150mm sluice valves - PN - 1 without bypass arrangement |
| 398 | Providing and supplying ISI standard D.I.specials & fitting with sealing rubber cascade of SBR complete with cast iron follower gland and MS nut bolts coated or otherwise protected from rusting and suitable for DI pipes inlcuding cost of labour, Materials, and transportation to stores/site, loading and unloading excluding GST levied by GOI and GOM in all respect, Complete as per IS 9523 for all types of specials, bends, tees etc. 9(80 to 300 mm dia) |
| 399 | Rising Main Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 /14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. 110 mm Dia HDPE Pipe 8 Kg/sqcm |
| 400 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete..Sluice valves 100 mm Dia. |
| 401 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete...Sluice valves 100 mm Dia. for Washout |
| 402 | Providing & supplying ISI mark CI D/F reflux valve (Non- returnvalve)offollowingdiaincludingalltaxes(central andlocal), railwayfreight, inspectionchargesunloading from railway wagon, loading into truck, transportation upto department stores/site, unloading, stacking etc. complete. reflux valves as per I.S.5312 part I (1984) Reflux valves 100 mm Dia |
| 403 | ProvidingandsupplyingAirvalvesasperIS-10845and MJP’s standard specifications of approved mark and quality offollowingdiametersincludingalltaxes (Central andlocal),railwayfright,inspectionchargesunloading fromrailwaywagons,loadingintotruck,transportation upto departmental stores/ site, unloading and stacking etc. complete.Air valves 25 mm Dia |
| 404 | Excavation for foundation/ pipe trenches in earth, soils of all types, sand gravel and soft murum, including removing the excavated material upto a distance of 50 meters & lifts as below, stacking & spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.(EARTH SOIL) |
| 405 | Excavation for foundation/pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back- filling, etc. complete.(HARD MURRUM) |
| 406 | Excavation for foundation/ pipe trenches in soft rock and oldcementandlimemasonryfoundationasphaltroad including removing the excavated material upto a distance of50Mbeyond areaandliftsasbelow,stackingas directed by Engineer-in-charges, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete.Soft Rock |
| 407 | Excavationforfoundation/pipetrenchesin hard rock and concrete road by chiselling, wedging, line drilling by mechanical means or by all means other than blasting includingtrimmingandlevellingthebed, removing the excavated material upto a distanceof50metresbeyondtheareaand lifts as below, stacking as directed by Engineer-in-charge,normaldewatering, excludingbackfilling,etc.completebyall means. (Bd-A-6/259)Hard Rock |
| 408 | Filling in plinth and floors murum bedding in trenches with approved murum from foundation 15 cm to 20 cm layers including watering and compaction complete. |
| 409 | Lowering, Laying and Jointing H. D. P. E./ M. D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II110 mm Dia HDPE Pipe 8 Kg/sqcm |
| 410 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) SLUICE valves 100 mm Dia |
| 411 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) Sluice valves 100 mm Dia. for Washout |
| 412 | Lowering laying and jointing inposition following C.I.D/F Reflux valves Butterfly valves and sluice valves including cost of all labour joining material, including not bolts and givingsatisfactoryhydraulictestingetc.complete.(Rate for all class of sluice valves) Reflux valves 100 mm Dia. |
| 413 | Lowering, Layingand fixing in proper alignment and position all types of C.I. Air valves as directed by Engineer in-charge including cost of conveyance from stores to site of work, cost of all material and giving satisfactory hydraulic testing, etc complete. Air valves 25 mm Dia- Single Bash |
| 414 | Providingandfixinginpositionairvalveshaftincluding providing and fixing GI Medium Class or 6 mm thick M.S. pipe shaft 2.70 M long over branch flange of air valve tee, providingPCCblockofM-150concrete150mmthick aroundtheairvalveteeincludingencasingofvertical shaft in PCC M-150 as shown in type design together with providingandmakingflangedjointswhereverrequired and fixing of air valve over the shaft excluding cost of air valve and branch flanged air valve tee. etc. complete as per type design and as directed by Engineer-in-charge for following diameters of pipe lines (type design attached.)upto 150 mm on Murum & harder strata |
| 415 | ProvidingandlayinginsitufollowinggradesofC.C.of trap/granite/quartzite/gneiss metal for foundation and bedding including dewatering, form work, compacting and curing, finishing etc. complete.b) 1:2:4 (M-150) grade for encasing |
| 416 | ProvidingandconstructingB.B.masonryvalvechamber with 15 cm thick 1:3:6 proportion PCC bedding, including excavation, B.B. masonry in C.M. 1:5proportion 12 mm thickcementplasterincm1:4proportiononbothsides with providing and fixing C.I. manhole frame and cover in RCC1:2:4copingorcmthickslabetc.completeas directed by Engineer-in-charge.Size 0.90 x 0.60 x 1.20 |
| 417 | Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15 cm layers with all leadsand lifts including consolidation, surcharging, etc. complete |
| 418 | Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.110 mm Dia HDPE Pipe 8 Kg/sqcm |
| 419 | Giving satisfactory hydraulic testing of following C.I. D / F Reflex valves, Butterfly valves and Sluice valves.Sluice valves 100 mm Dia. |
| 420 | Sluice valves 100mm Dia. for Washout |
| 421 | Reflux valves 100 mm Dia. t |
| 422 | Pressure Filter - 20cum/hr |
| 423 | DISTRIBUTION SYSTEM Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i.e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, including transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete.63 mm dia HDPE PN 8 Pipes |
| 424 | 75 mm dia HDPE PN 8 Pipes |
| 425 | 90 mm dia HDPE PN 8 Pipes |
| 426 | 110 mm dia HDPE PN 8 Pipes |
| 427 | 125 mm dia HDPE PN 8 Pipes |
| 428 | 140 mm dia HDPE PN 8 Pipes |
| 429 | Providing HDPESpecialsasperstandard specifications&directionofinchargeEngineer.(5%of Item No.2) |
| 430 | Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure, stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete Sluice valves 65 mm Dia |
| 431 | Sluice valves 100 mm Dia |
| 432 | Excavation for foundation / pipe trenches in earth, soils of all types, sand, gravel and soft murum, including removing the excavated material upto a distance of 50 metres and lifts as below, stacking and spreading as directed, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-1/259)(EARTH SOIL) |
| 433 | Excavation for foundation / pipe trenches in hard murum and boulders, W.B.M. road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (BdA-3/259) (Hard Murrum) |
| 434 | Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation asphalt road including removing the excavated material upto a distance of 50 M beyond the area and lifts as below, stacking as directed by Engineer-incharge, normal dewatering, preparing the bed for foundation and excluding backfilling, etc. complete. (Bd-A-4/259)(Soft Rock) |
| 435 | Excavation in hard rock masses mechanically, including lift upto 1.5 M including trimming and levelling the bedremoving the excavated material upto a distance of 50 metres beyond the area and lift as below stacking by as directed by Engineer-in-charge, normal dewatering excluding backfilling, etc. complete. (Hard rock) |
| 436 | Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation in 15 cm to 20 cm layers including watering and compaction, etc. complete. (Bd-A-10/263) |
| 437 | Lowering, Laying and Jointing H. D. P. E./M.D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulic jack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II. 63 mm dia HDPE PN 8 Pipes |
| 438 | 75 mm dia HDPE PN 6 Pipes |
| 439 | 90 mm dia HDPE PN 6 Pipes |
| 440 | 110 mm dia HDPE PN 6 Pipes |
| 441 | 125 mm dia HDPE PN 6 Pipes |
| 442 | 140 mm dia HDPE PN 6 Pipes |
| 443 | Lowering, laying and jointing in position following C.I.D/F Reflex valves, Butterfly valves and Sluice valves including cost of all labour jointing material, including nut bolts and giving satisfactory hydraulic testing etc. complete. (Rate for all class of valves.)Sluice Valve 65 mm Dia |
| 444 | Sluice Valve 100 mm Dia |
| 445 | Providing and laying in situ Cement Concrete of trap/ granite / quartzite /gneiss metal for RCC work in foundation like raft, grillage, strip foundation and footing of RCC columns and steel stanchions including normal dewatering,form work, compaction, finishing and curing, etc. complete. (By weigh batching and mix design for M250 and M-300 only. Use of L&T, A.C.C., Ambuja, Birla Gold, Manikgad, Rajashree, etc. cement is permitted.) (Excluding M.S. or Tor reinforcement)a) 1:2:4 (M-150) grade for Thrust Blocks b) 1:2:4 (M-150) grade for encasing |
| 446 | Providing and constructing B.B. masonry valve chamber with 15 cm thick 1:3:6 proportion PCC bedding, excluding excavation, B.B. masonry in CM 1:5 proportion precast RCC frame and cover, etc. complete as directed by Engineer-in-charge. As above of 90 x 60 cm internal size and depth upto 1.2 M with precast R.C.C slab cover. |
| 447 | Refillingthetrencheswithavailableexcavatedstuffwith soft materialfirst over pipeline andthen hardmaterial in 15cmlayerswithallleadsandliftsincluding consolidation, surcharging, etc. complete |
| 448 | Hydraulic testing of H. D. P. E./ M. D. P. E./D.I. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position. 63 mm dia HDPE PN 8 Pipes |
| 449 | 75 mm dia HDPE PN 8 Pipes |
| 450 | 90 mm dia HDPE PN 8Pipes |
| 451 | 110 mm dia HDPE PN 8Pipes |
| 452 | 125 mm dia HDPE PN 8Pipes |
| 453 | 140 mm dia HDPE PN 8Pipes |
| 454 | Providingandfixingboarddisplayinginformation, such as \"Name of work, Tender cost, Name of Contractor, Work completion and liability period etc\", having rectangularshapeof1.20mx0.90msize made out 18 gauge (1.25 mm) thick mild steel sheet painted with one coat of Zinc chromate stoving primer and two coats of enamel paint on front side and grey stoveenamelonbacksideandborder/messages /symbols etc. with approved colour shade paint complete, on M.S.angle of size 35 x35 x3 mm frame with properly cross braced M.S.angles of size 35 mm x 35 mm x 3 mm duly painted including Two M.S.angle iron posts of size 65 mmx 65 mmx 6 mm, 3.65mlongpaintedwithalternateblackandwhite bandsof25cmwidthincludingallfixturesetc.and fixing the boards in 1:4:8 concrete block of size 60 cm x60cmx75cmincluding,excavation,refilling, transportation,andlabouretccomplete.Spec. Number As directed by Engineer in Charge MORTH 801 |
| 455 | Providing and making UPVC/MDPE pipe consumer service connection on Distribution main by drilling hole with suitable means , including all labour ,UPVC/MDPE Pipe of required lengthwith or without Road crossing as described below, including cost of specials likeaddle/Clamp Saddle of suitable material, and diameter suitablefor Distribution main, 15mm /20mm/ 25mm respective Dia Heavy duty Brass/Polyprophylyne(Twin Jacketed ) Ferrule , Male and Female thread adapter Elbow, Bends,couplers ,Tees, Clamps of suitablematerialand sundry materials as per requirment, including providing and fixing medium duty 15.mm brass bib tap, GI casing pipe of suitable diameter of 32mm/ 40mm/ 50mm respectively of required length for Road crossing, including requird labour for excavation in alltypes of strata up to the depth of 0.75m or as per site requirement,all types of plumbing fittings, refilling , Closing the water supply in that area, dewatering, hydraulic testing and restarting the water supply ,transportation of material etc. complete as directed by Engineerin charge.B)Household Connection without watermeter (With Integrated Saddle & compression Specials) For HDPE/PVC WITH ROAD CROSSING 15 MM SERVICE CONNECTION |
| 456 | WITHOUT ROAD CROSSING 15 MM SERVICE CONNECTION |
| 457 | MISC ITEM MSED |
| 458 | Providinq andLayinq insituCement Concrete M-15 of trap/ granite / quartzite / gneiss metal for foundation and beddinq including baidng outwater,form work, compaction, curing, etc. complete. (Cement 5.90 bags / cum)b) In PCC M-150Road Restoration WorkConcrete Road |
| 459 | Trial Run(3months) |
AI Tender Summary
Tender Timeline
Oct 10, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedOct 25, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 27, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender