Repair To Internal Electrification Including Meters Ceiling Fan Geyser And External Electrification Including Fps Dbs Lt Panel Cable Street Light And Apfc At Iam And Challaghatta Under Ge Af Marathahalli, marathahalli-Karnataka

Military Engineer Services-MES has published Repair To Internal Electrification Including Meters Ceiling Fan Geyser And External Electrification Including Fps Dbs Lt Panel Cable Street Light And Apfc At Iam And Challaghatta Under Ge Af Marathahalli. Submission Date for this Tender is 03-11-2022. Electrification Work Tenders in marathahalli Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

34271278
Corrigendum : Repair To Internal Electrification Including Meters Ceiling Fan Geyser And External Electrification Including Fps Dbs Lt Panel Cable Street Light And Apfc At Iam And Challaghatta Under Ge Af Marathahalli
Open Tender
Indian
Karnataka
marathahalli
03-11-2022

Tender Details

Repair To Internal Electrification Including Meters Ceiling Fan Geyser And External Electrification Including Fps Dbs Lt Panel Cable Street Light And Apfc At Iam And Challaghatta Under Ge Af Marathahalli

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Oct-2022 BOQ CORRIGENDUM_1 BOQ 27-10-2022
2 27-Oct-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 03-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 47800.0 /-
Tender Value
INR 23.90 Lakhs /-

BOQ Items

Name of Work: REPAIR TO INTERNAL ELECTRIFICATIONINCLUDING METERS, CEILING FAN, GEYSER AND EXTERNAL ELECTRIFICATION INCLUDING FP"S, DB"S, LT PANEL, CABLE STREET LIGHT AND APFC AT IAM & CHALLAGHATTAUNDER GE (AF) MARATHAHALLI
Sl. No. Item Description
1Taking down unserviceable wire carefully from copper/ aluminum point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling roses, regulators, sockets, light fittings, fans etc., and making good the disturbed surfaces of walls, ceiling etc., including painting with same colour of the background, complete all as specified and as directed.
2Taking down carefully Unserviceable Sub main wiring of any size and type batten or conduit, surface or concelaed including removing material from site and making good the disturbed surfaces of walls, roofs etc to match the existing Complete all as specified and as directed. Note: Taking down of Fittings and Fixtures shall be measured under respective Items Separately.
3Material and Labour for Wiring complete with 1.5 Sqmm single core FRLSPVC insulated unsheathed cable 1100 volts grade multi stranded with copper conductor conforming to IS 694 drawn through and incl non-metalic rigid PVC conduit incl accessories surface type run on walls/ ceiling incl MS terminal boxesmounted concealed on walls with suitable size moduler coverplate inner and outerfixed withmachin screws for housing the moduler switches, switch socket , fan regulators etc., incl provision of 1.5 Sqmm FRLS PVC insulated single core multi stranded copper conductor cable as earth continuity conductor and connecting to common earth dolly for One Light point controlled by one switchall as specified and as directed.
4Description all as per item No 3 above but one fan/Exhaust. fan point controlled by one switch.
5Description all as per item No 3 above but one 5A 2pin/3pin switch socket out let multipurpose on independent Board.
6Description all as per item No 3 above but one 5 Amps socket point on same board with other switches
7Description all as per item No 3 above but one call bell point controlled by one bell push
8Description all as per item No 3 above but wiring complete with 2.5Sqmm for 5 pin 5/15A socket multipurpose on independent board Note:- item No03to 08 (i) The earth wire for the points shall be laidfrom the respective switch board only . (ii) Earth wire shall be taken inside the conduit (iii)Cost of terminal box and moduler cover inner and outeraredeemed to be included in the item rate quoted for point wiring
9S & Fin repair Modular Switch 1 way 6 Amps 1 Module .
10S & F in repairModular Socket,6 Amps- 2/3 pin combined 2 Moduler.
11S & F in repairModular Switch 1 way 16 Amps 1 Moduler.
12S & F in repairModular Socket,6 A/16A,2 Moduler.
13S & Fin repairModular bell push 6A,1 Module.
14S & F in repair Modulartype Fan step regulator 120Wtype2 moduler
15S & Fin repair Switch piano flush type, single pole, one way5 Amps.
16S & Fin repairSwitch socket combination 2 -in-1, 3 pin/5 pin, 5 Amps 230 volts.
17S & F in repairSwitch Socket Combination 2 in 1, 3 pin 5 Amps and 15 Amps flush type, 230 volts .
18S & Fin repair Socket outlet 2 in 1, 3 pin, 5A Flush type 230 volts.
19S & F in repair Socket Outlet 2 in 1, 3 pin, 5 and 15 amp flush type 230 volts
20S & Fin repair Switch Piano Flush type, Single pole, One way 230 volts 15 / 16 Amps
21S & F in repair step type electronic fanregulator, - 2 module.
22S& Fin repairPVC ceiling rosetwo to threeterminalsall as specified.
23S & Fin repair ding dong bell AC, 230 volts, single pole complete.
24S & F in repairPVC Gang box suitable for 5 Amp S/S combination
25S & F in repairPVC Gang box suitable for 15 Amp S/S combination
26S&F in repairAngle holder PVC/polycarbonate type all as specified and as directed
27Supply and fixingin repair 600x600mm surface/ recessed mounted LEDLight fitting 36 /35 W,glare freeuniform illuminationacrylic diffuser,connector block etc., complete with all accessoriesand including connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal complete all as specified and as directed.
28Supply and Fixing in repairs LED Tube light fitting 1 x20 W,220VCRCAhousing withPC diffuserbox type with driver,holder including LED tube light connecting upwith 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal all as specified and as directed.
29Supply and fixing in repairround /square shape LED recessed/ surface light fitting 15Wcomplete withdrivers ,holders LED lampsincluding connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal Complete all as specified and as directed.
30Supply and fixing in repair LEDlight fitting 10Wsurfce type2 feet longcomplete withdrivers ,holders LED lampsincluding connecting up with 3 core 0.5sqmm copper wire between ceiling rose and fitting terminal Complete all as specified and as directed.
31Supply and Fixingin repairsretro type LEDT8 tube with entrudedAl body, PC diffuser and inbuilt driver 8 W .Make CG , cat part No- LTT 8-8
32Supply and Fixingin repairsretro type LED glass T8 tubein built driver,20 W .Make CG , cat part No- LGT8-20-865-2
33Supply and Fixing in repairs MCB DB SPN 8 way,Double door, 240 V, AC, 50 Hz, with 200Amp rated bus bar
34Supply and Fixing in repairs Metal clad switch socket Single pole and neutral enclosure with a two pin and earth plug and socket complete with One single pole MCB SP 20 Amps and fixed in walls Complete all as specified and as directed.
35Supply and Fixing in repairs MCB DB TPN4 way, double door,415 V, AC, 50 Hz,
36Supply and Fixing in repairs MCB SP 5 to 32 Amps rating, 10 KAÇ "curve240V, 50 Hz AC Complete all as specified and as directed.
37Supply and Fixing in repairs MCB SPN 32 Amps rating,10 KA "C"curve, 240V, 50 Hz AC Complete all as specified and as directed.
38Supply and Fixing in repairs MCB TP 25- 63 Amps rating, , 10 KA Ç" crve415V, 50 Hz AC complete all as specified.
39Supply and Fixing in repairs MCB TPN 63 Amps rating,, 10 KA Çcurve , 415V, 50 Hz AC Complete all as specified and as directed.
40Material and Labour forsub main wiring1100 volts grade PVC insulatedFRLS multistranded copper conductors, two runs of single core4 Sqmm along with one run 10 Sqmm PVC insulated single core FRLS multistranded copper conductor cable as earth continuity conductor along with one run of PVC medium grade conduit all as specified and as directed. Note :-Three runs ofmultistranded copperconductorand 1 run of PVC conduit shall be measured as one unit,
41Material and Labour forsub main wiring1100 volts grade PVC insulatedFRLS multistranded copper conductors, two runs of single core 2.5 Sqmm along with one run 2.5 Sqmm PVC insulated single core FRLS multistranded copper conductor cable as earth continuity conductor along with one run of PVC medium grade conduit all as specified and as directed. Note :-Three runs ofmultistranded copperconductorand 1 run of PVC conduit shall be measured as one unit,
42Disconnecting the powersupply and taking down Ceiling fan ,Dismantling the defective Ceiling fans motor 1200mm sweep taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material and other petty items required for making motor functional Complete all as specified and as directed.
43Disconnecting the power supply and taking down the exhaust fan , dismantling the defective Exhaust fans motor up250mm to300 mm sweeptaking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, andother petty items required for making motor functional Complete all as specified and as directed.
44Disconnecting the power supply and taking down the exhaust fan ,/wall mounting fandismantling the defective Exhaust fans motor up 400 to 450 mm sweeptaking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, andother petty items required for making motor functional Complete all as specified and as directed.
45Dis connecting the power supply and taking down the wall mounting fan300 to 450 mm ,taking to work shop and by taking out burnt copper winding and rewinding with super enamelled copper wire of existing gauge and weight including replacement of all insulation material, andother petty items required for making motor functional Complete all as specified and as directed. Note: item No -42 to 45- Servicing of Fans/Exhaustfans and Spares will be measured and paid separately under relevant items of this schedule.
46Material and Labour for Painting of Ceiling fan /Exhaust fan up to 450mm complete, at site with synthetic enamel paint by spraying painting including filling cavities with filler,one coat after cleaning Complete all as specified and as directed.
47Hanging Only Ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan all as specified ,and any addn/alteration /threading if required to down rod shall be done by contractor with out any extra cost Complete all as specified and as directed.
48Fixing only Exhaust fan and connecting up including nuts and bolts if required and provison of cable from ceiling rose /connector to fan
49Supply Only GM bush suitable for Ceiling fan 1200 Sweep Complete all as specified and as directed.
50Supply Only Ball bearings suitable for Ceiling fans / Exhaust fans / Wall mounting fans of 1200 Sweep Complete all as specified and as directed. Make: SKF / NBC / TATA .
51Supply Only 2.5 MFD Capacitors for the fan in position Complete all as specified and as directed. Make - Usha / CG/ Havells
52Supply Only 4 MFD Capacitors of the fan in position Complete all as specified and as directed. Make - Usha / CG/ Havells
53Material and labour for repairing /replacingthe unserviceable door hinges,rubber beeding ofexisting distribution board with meter box atvarious buildingat IAM OE of size approx 1.2Mx 1.02Mx 0.5M, scraping and removingthe old paint , rust anddust ,painting two coat of red oxide over a coat of synthatic smoke gray enamel paint and writting the distribution area of qtr no all asdirectedat site.
54Taking out unserviceable geyser element and Supply &fixingheating elementsuitable to existing model and make 2 KW Dual clip type/tri angle type / round type with rubber gasketsuitable for geysers up to 50 Ltr capacity . Make: Theeta /Elteck.
55Taking out unserviceable thermostat and Supply & fixingthermostat clip type (Range 30 C° to 80 C and acting at 70C°) forgeysers up to 50 Lts all as specified . Make: Elcon
56Takingout un serviceable PVC connection and Supply & fixing15mmbore PVC connections with brass nuts650 mm in length suitable to connect GI pipe 15 mm dia to hot /Cold water outlet of geyser. Complete all as specified and directed by Engr-in- charge .
57Taking out unserviceablepressure release valve and Supply& fixing pressure release valves suitable for geyser up to 50 ltrs capacity type asper existing PR valve complete all as specified and directed by Engr-in- charge
58Taking out unservice indication lamp and Supply &fixingindicating lamps green / red suitable forgeysers up to 50 Ltrs completeall specified and directed by Engr-in- chrge
59Taking out the unservieable 3 core wire supply and fix FRLSPVCinsulated copper flexible cable 2.5 sqmm , 3 core PVC sheathed,1100 Volts grade complete allas specified and directed by Engr-in-charge
60Supply and fix electric water heater storage type steel body with copper inner tank and heating element up to 2 KW capacity 25 litre,BEE 5 star rated complete with all accessories such as safety valve ,thermostate, NRV PV C hot water connection pipeall as specified and directed by Engr-in- charge
61Supply only CFL lamp4pin 36 W
62Supply only CFL lamp4pin 18W
63Supply only CFL lamp 2 pin18 W
64Supply and Fixing in repairs MCCB Triple pole 415 volts 50 HZ AC suitable for current carrying capacity 25 to 100 Amps rating, fixed typewith rupturing capacity 16 KA all as specified and directed.
65Excavation in trenches in Soft / Loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient Complete all as specified and as directed.
66Excavation in trenches in hard/dense/ Loose soil not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying of cables etc, getting out and forming bottom surface to required gradient Complete all as specified and as directed.
67Returning filling including Spreading levelling watering and well ramming to excavated soil in layers not exc 25 cm thick each Complete all as specified and as directed
68Removing excavated material to a distance not exc 50m and depositing where directed at a level not exc 1.5m above the starting point in soils Complete all as specified and as directed.
69Material and labour forriddledSandCushioning to cablesa layer of 8 cm thick beforelaying the cable and second layer of 15 cmthick after layingthe cable Complete all as specified and as directed. Note :- Sand shall be measured after punned down.
70S & Fsub class B burnt Bricks for cable protection Complete all as specified and as directed
71Material and Labour for G.I. tubinglightgrade of size 50mm bore for protection of cables to be laid under roads, crossings / culverts Complete all as specified and as directed.
72Boring of holes under roads,pavement,hard standing by trenchless technology using ultra sounding technique andnecessary machine including HDPE pipe of 150mmdia suitable for .4 mpa working pressure
73Taking out old unserviceable UG cable and Supply & laying 70 Sqmm, 3.5 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
74Taking out old unserviceable UG cable and Supply & laying 50 Sqmm, 3.5 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
75Taking out old unserviceable UG cable and Supply & laying 35 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
76Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size Upto 35, Sqmm 3.5 / 4 core Complete all as specified and as directed. Make:- 3M Code- HSLA - 2/4C or equivalent in Densons.
77Material and Labour for Straight through joints (Epoxy) heat shrinkable type for UG cable including jointing kit and all accessories complete for making joints suitable for LT UG Cable of Aluminium conductor of size 50 to 95, Sqmm 3.5 / 4 core Complete all as specified and as directed. Make:- 3M Code- HSLA - 2/4C or equivalent in Densons. Note for ser item No.66 & 67 (i) Earth work excavation, sand cushioning, bricks for protection, GI pipe etc shall be measured and paid for separately under relevant items of this schedule.
78Supply and Fixing in repairs MCCB 3 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 160 Amps rating, fixed and thermal magnetic release with rupturing capacity 25 KA all as specified and directed.
79Supply and Fixing in repairs MCCB 4 Pole, 415 volts 50 HZ AC suitable for current carrying capacity 200 Amps rating, fixed and thermal magnetic release with rupturing capacity 35 KA all as specified and directed.
80Supply and Fixing in repairs MCCB4Pole, 415 volts 50 HZ AC suitable for current carrying capacity 250 Amps rating, fixed and thermal magnetic release with rupturing capacity 35 KA all as specified and directed.
81Supply and Fixing in repairs MCCB4Pole, 415 volts 50 HZ AC suitable for current carrying capacity400 Amps rating, fixed and thermal magnetic release with rupturing capacity 36 KA all as specified and directed.
82Supply and Fixing in repairs Voltmeter digital type 0-500 Volts Complete all as specified and as directed.
83Supply and Fixing in repairs Ammeter digital type 0-200 Amps Complete all as specified and as directed.
84Supply andlaying Synthetic rubber insulating Matssuitable for 11 KVelectrical insulation 2 Mtr x 1 Mtr x2.5 mm thick Complete all as specified and as directed.
85Earthing complete with galvanized iron or steel plate electrode 600 mm x 600 mm x 6.0 mm buried directly in ground vertically in pit of depth not less than 2.25 metre below normal ground level with top edge of the earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides with mixture of charcoal and common salt in alternate layers and electrode connected to GI earth earth strip 25 x 3 mm by means of GI bolts, nuts, check nuts and washers, earth wire protected by galvanized steel pipe 15 mm bore (light grade) connected to machinery/ equipment all as shown in Electrical plate No. 3 of SSR-2009 Part I and including necessary excavation and earth work in any type of soil, 20 mm bore light grade GI pipe for watering funnel wire mesh, PCC (1:3:6), type C-1 chamber, RCC (1:2:4), type B-1, reinforced with 6 mm dia MS round bars @ 15cm c/c both way for cover and MS frame etc., Complete all as specified.
86Repair/ servicing of in door typeAPFC panelat IAM :- (i) APFC panel (In door Type) 100 (28x3.5) KVAR - 01 No Tech Area, (ii) APFC panel (In door Type) 50 (15x3.5) KVAR - 01 No IAMOE, (iii) APFC panel (In door Type) 150 (6x25) KVAR - 01 No 400 KVA DG ROOM, (iv) APFC panel (In door Type) 100 (5x20) KVAR - 01 No HPHC IAM, capacitors, internal wiring,inresh current limiting coil ., auxillary contactor, indicating lamps, auto-manual selector switch, MCCB, axial flow fan and replace the unserviceable parts complete all as specified and as directed. The following checking will be carried outto ensure smooth and effective operation all the timeall as specified and directed. (a) Checking of the control panel, power supply, fuses, circuits etc and tighten to any loose contact.(b) Checking of the healthiness of capacitors, contactors and APFC relays. (c) Cleaningof the panel by using blower without any disturbance/ damages. Note:- spare parts materialwill be measured and paid separately under relevant items of this schedule.
87Repair/servicing of out door type r APFC panelat VAYU VIHAR:- (i) APFC panel (Out door Type) 60 KVAR - 01 No, (ii) APFC panel (Out door Type) 40 KVAR - 01 No, Capacitors, internal wiring,inresh current limiting coil , auxillary contactor, indicating lamps, auto-manual selector switch, MCCB, axial flow fan and replace the unserviceable parts complete all as specified and as directed. The following checking will be carried outto ensure smooth and effective operation all the timeall as specified and directed. (a) Checking of the control panel, power supply, fuses, circuits etc and tighten to any loose contact.(b) Checking of the healthiness of capacitors, contactors and APFC relays. (c) Cleaningof the panel by using blower without any disturbance/ damages. Note:- spare parts materialwill be measured and paid separately under relevant items of this schedule.
88Supply Only in repairs 3.5 KVAR Capacitor heavy duty existing make and type440 volts with inrush current Limiting Coil Complete all as specified and as directed.
89Supply Only in repairs5 KVAR Capacitor heavy duty existing make and type440 volts with inrush current Limiting Coil Complete all as specified and as directed.
90Supply Only in repairs 10KVAR Capacitor heavy duty existing make and type440 volts with inrush current Limiting Coil Complete all as specified and as directed.
91Supply Only in repairs 15KVAR Capacitor heavy duty existing make and type440 volts with inrush current Limiting Coil Complete all as specified and as directed.
92Supply Only in repairs 20KVAR Capacitor heavy duty existing make and type440 volts with inrush current Limiting Coil Complete all as specified and as directed.
93Supply Only in repairs 25KVAR Capacitor heavy duty existing make and type440 volts with inrush current Limiting Coil Complete all as specified and as directed.
94Supply Only Automatic power factor relay ( APFCR )8 stage Complete all as specified and as directed. Make - Neptune
95Supply only duty contactor suitable for 25Kvar capacitor
96Supply only duty contactor suitable for 20Kvar capacitor
97Supply only duty contactor suitable for10Kvar capacitor
98Material and Labour for preperation of old painted steel surfaces of any description over 10 cm width or girth and applying one coat of synthetic enamel paint Complete all as specified and as directed.
99Supply and fixingmoulded (FRP) junction boxwith IP 65 protection of size 300x200x80mm with 32 Amp 4 way heavy duty terminal block with 6Amp MCBSP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole complete all as directedMake- sintex
100Disconnecting the electrical connections and taking down the unserviceable LED Street light fittings of 75/45/25 watts of any type and any make from pole for repair and replacement of unserviceable parts like driver, surg protectionetc., and fixing back to the original position after getting repairs including connecting testing and commissioning all as specified and directed by Engr- in- Charge.
101Taking out the unserviceable HPSV /CFL street light fitting any watts , Supply and fixing 1x 60 WLEDstreetlight fitting with pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection.
102Taking out the unserviceable HPSV /CFL street light fitting any watts , Supply and fixing 1x70 WLEDstreetlight fitting with pressure die-cast housing with toughened glass and individual LEDs with secondary optics and IP 66 protection.
103Taking out the unserviceableflood light fittings and Supply & fixing 1x70 WLED flood light fitting230V out door type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistants complete with driver and lamp
104Taking out the unserviceable post top latern fitting and Supply & Fixingpost top lantern LED type 40 W 230 VoltsAC out door typewith decorativepost top for 360 degree indirect light IP65protection with impact and corrosionresistantCompletewith driver and lamp
105Taking down unserviceable bollard fitting andSupply & FixingLED bollard10 W in cylindrical shape with opal acrylic diffuser and IP 65 protection.with necessary electrical connection Make CG cat part No- LBLA1-10-CDL or equivalent in PHILIPS/WIPRO
106Taking downunserviceable mashroom light fittings ,Supply and Fixingmushroom LED light fitting 16 Wdie-cast aluminium landscape luminaire for downward lighting with high power led as light source, IP 66 complete all as specified and directed.Make Havells cat par tNo -MUSHROOMBL 16WLED730SSYMTOPCor equivalent in PHILIPS/WIPRO
107Taking out old unserviceable UG cable and Supply & laying 16 Sqmm, 4 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.
108Taking out old unserviceable UG cable andSupply & laying 10 Sqmm, 2 Core LT UG cable grade PVC XLPE insulated, PVC sheathed armoured, heavy duty, in trenches / walls / poles / passing through pipes with multistranded aluminium conductor including lugs / thimbles / ferrules connection, testing and commissioning Complete all as specified and as directed.