| 1 | Operation of 2 x 2.5 MVA transformer substation i/c all accessories like HT Panel, LT Panel, Capacitor panel, UPS, HT/LT Cable (including cable jointing & end termination), Bus duct, plug in box, rising main etc as reqd by providing necessary Engineer, supervisor, electrician , helper etc as reqd.Site Engineer (For residential campus substation 3, 4 &4A ) |
| 2 | Operation of 2 x 2.5 MVA transformer substation i/c all accessories like HT Panel, LT Panel, Capacitor panel, UPS, HT/LT Cable (including cable jointing & end termination), Bus duct, plug in bix, rising main etc as reqd by providing necessary Engineer, supervisor, electrician , helper etc as reqd.Electrician (For substation 3, 4 &4A) |
| 3 | Operation of 2 x 2.5 MVA transformer substation i/c all accessories like HT Panel, LT Panel, Capacitor panel, UPS, HT/LT Cable (including cable jointing & end termination), Bus duct, plug in bix, rising main etc as reqd by providing necessary Engineer, supervisor, electrician , helper etc as reqd.Semi skilled Electrician (For substation 3,4 &4 A) |
| 4 | Comprehensive maintenance of 2x 2500 KVA transformer sub station i/croutine/ preventive / breakdown maintenance of follwing equipments with components, equipments, T & P i/c manpower/ labours/electrician etyc involved in maintenance apart from item no ( 1 )above For Substation (3 & 4) a) 2.5 MVA transformer (11/0.4KV)-2nosb) 11KV HT Breaker- 4nosc) 550KVAR Capacitor panel -2nos d) LT Panel (Capacitor I/P & O/P, LT Distribution panel)- 1 no e) Bus Duct- Lump sump f) HT/LT cable network-( including cable jointing & end termination)g)Rising Main (Hospital complex i.e IPD,Trauma and APMR)-2000mtrs (Approximate)h) Plug in Box-200 nos |
| 5 | Comprehensive maintenance of 2x 300 KVA UPS i/c routine maintenance etc as reqd ( Cost of Replacement of battery is not the part of AMC) For Substation (3 & 4) |
| 6 | Comprehensive maintenance of1250 KVA transformer sub station i/croutine/preventive maintenance of follwing equipments with components, equipments, T & P i/c manpower/labours/electrician etc involved in maintenance apart from item no ( 1 )above For Substation (4A)a) 1250 KVA transformer (11/0.4KV)-1nob) 11KV HT Breaker- 3nosc) 250KVAR Capacitor panel -1nos d) LT Panel (Capacitor I/P & O/P, LT Distribution panel-2)- 1 no e) Bus Duct- Lump sump f) HT/LT cable network-( including cable jointing & end termination)g)Rising Main (Hospital complex i.e OPD )-500mtrs (approximate) h) Plug in Box-40 nos |
| 7 | Operation of 2x 750 KVA transformer sub-station i/c all accessories like HT Panel, LT Panel, capacitor panel, UPS, HT/LT cable (including cable jointing & end termination), Bus duct, plug in box, rising main etc as reqdby providing necessary Engineer, Electrician, helper etc as reqd (The superviser taken at sr no 1 above will supervised both substation)Electrician (For residential complex substation) |
| 8 | Operation of 2x 750 KVA transformer sub-station i/c all accessories like HT Panel, LT Panel, capacitor panel, UPS, HT/LT cable (including cable jointing & end termination), Bus duct, plug in box, rising main etc as reqdby providing necessary Engineer, Electrician, helper etc as reqd (The superviser taken at sr no 1 above will supervised both substation)Semi skilled Electrician (For residential complex substation) |
| 9 | Comprehensive maintenance of 2x750KVA transformer sub station i/croutine/preventive maintenance of follwing equipments with components, equipments, T & P i/c manpower/labours/electrician etyc involved in maintenance apart from item no ( 1 )above a) 750 KVA Transformer(11/04KV)-2nos b) 750KVA DEA set (only for operation if reqd)c) 11KV HT Breaker -3nosd) Capacitor Panel-2nose) LT Panel(Capacitor I/P & O/P, LT Distribution panel- 1no f) HT /LT Cable network (including cable jointing & end termination) |