Rate Contract & Empanelment Of Contractors For Composite Works ( Mechanical & Electrical Works ) For Development Of Different Type Of Cng Stations At Various Geographical Areas In The States Of Punjab, Maharashtra, Rajasthan, West Bengal, And Ut Of , noida-Uttar Pradesh

Indian Oil Corporation Limited-IOCL has published Rate Contract & Empanelment Of Contractors For Composite Works ( Mechanical & Electrical Works ) For Development Of Different Type Of Cng Stations At Various Geographical Areas In The States Of Punjab, Maharashtra, Rajasthan, West Bengal, And Ut Of . Submission Date for this Tender is 27-10-2022. Electromechanical Work Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34269613
Corrigendum : Rate Contract & Empanelment Of Contractors For Composite Works ( Mechanical & Electrical Works ) For Development Of Different Type Of Cng Stations At Various Geographical Areas In The States Of Punjab, Maharashtra, Rajasthan, West Bengal, And Ut Of
Open Tender
Indian
Uttar Pradesh
noida
27-10-2022

Tender Details

Rate Contract & Empanelment Of Contractors For Composite Works ( Mechanical & Electrical Works ) For Development Of Different Type Of Cng Stations At Various Geographical Areas In The States Of Punjab, Maharashtra, Rajasthan, West Bengal, And Ut Of Jammu & Kashmir ( Group-B )

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Oct-2022 CORRIGENDUM-1 Technical Bid 27-10-2022

Key Value

Document Fees
Refer document
EMD
INR 695000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: RATE CONTRACT & EMPANELMENT OF CONTRACTORS FOR COMPOSITE WORKS (MECHANICAL & ELECTRICAL WORKS) FOR DEVELOPMENT OF DIFFERENT TYPE OF CNG STATIONS AT VARIOUS GEOGRAPHICAL AREAS IN THE STATES OF PUNJAB, MAHARASHTRA, RAJASTHAN, WEST BENGAL, AND UT OF JAMMU & KASHMIR (GROUP-A)
Sl. No. Item Description
1GST % for this Tender Please select the rate of GST in Cell AY13. Rate selected shall be applicable for the entire BOQ.
2Laying, testing and commissioning of SS tubes along with fittings as per Technical Specification, Typical P & ID for type of CNG station and scope of work, handling, lifting, transportation from stores toCNG stations.
3¾”OD X 0.095” min Wall thk.SS Tube
4½”OD X 0.083” min Wall thk.SS Tube
5SUPPLY OF SS TUBES as per Technical Specification
6¾”OD X 0.095” min Wall thk.,Material SS316SS Tube
7½”OD X 0.083” min Wall thk.,Material SS316 SS Tube
8Quick Connect Body & Stem
9QRC of 3/8" NPT , end connection:½" Tube OD, for stem & ½”NPT (F) for body MaterialSS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F
10Plug
11Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
12Size : ¾" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
13Caps
14Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
15Size : ¾" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
16Union
17Size : ¾” OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
18Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
19Reducing Union
20Tube OD 3/4" x Tube OD 1/2", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
21Equal Tee
22Size:½” OD x ½” OD x ½” OD, Material:SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
23Size:¾" OD x ¾" OD x ¾" OD, Material : SS316 ( Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
24Reducing Union Tee
25¾" OD x ½" OD x ¾" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
26Tube End Connection
27½” Tube End & ¾” OD with Ferrule Fitting, SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
28Nut
29¾ " OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
30½" OD, Material : SS316(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F)
31Front Ferrule
323/4" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
33½" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
34Back Ferrule
353/4" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
36½" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
37Male Connector
38Size ¼” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
39Size 1/2” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
40Cross
413/4" OD X 3/4”X 3/4" OD X3/4" OD Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F)
42SS Ball Valves of following sizes as indicated below as per Tender Specifications and Instruction of Engineer-In-Charge:
432-Way Floating Normal Bore Ball Valve ¾"
442-Way Floating Normal Bore Ball Valve ½"
453-Way Trunnion Mounted, Reducer BoreBall Valve ½" OD end Connection and ¼” NPT (F) bottom end connection
46Conductive Core Thermoplastic Hose
473/8” ID Conductive Core Thermoplastic Hose for CNG Service with break away coupling ( 3 Meter )
48Supply , Laying, testing and commissioning of SS 304 Tubes along with isolation valves, reducers & fittings etc.as per Technical Specification, Typical schematic drg. for Ins. air line of CNG station and scope of workincluding handling, storage,lifting, transportation upto CNG stations.(Note:Total no.offerrule fittings may be considered as one jointing ferrule at every 5.0 m)
491/4”OD X 0.035” min Wall thk.SS Tube
50Handling (including lifting and transportation from Client"s store within city toCNG stations)and erecting in position, the following equipmenteither on the foundation at Ground level or on roof at 3.0 m above ground level.Contractor"s scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc. : Note: The quantities given below against individual items are indicative and shall not be considered to be binding.The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge.The unit rate shall be operated to work out the final payment due to Contractor.
51Cascade 4500/3000 L water capacity. Erection at + 3.0 M level
52Cascade 4500/3000 L water capacity, Erection at + Ground level
53Dispenser Erection at + Ground Level
54Handling (including lifting within CNG stations) and erecting in position, the following equipmenteither on the foundation at Ground level or on roof at 3.0 m above ground level.Contractor"s scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc. : Note: The quantities given below against individual items are indicative and shall not be considered to be binding.The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge.The unit rate shall be operated to work out the final payment due to Contractor.
55Cascade 4500/3000 L water capacity. Erection at + 3.0 M level
56Cascade 4500/3000 L water capacity, Erection at + Ground level
57Dispenser Erection at + Ground Level
58Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC Fire fighting Equipments
59DCP -10 Kg
60DCP -75 Kg (trolley mounted)
61CO2 – 4.5 Kg (portable)
62Sand Bucket with stand and canopy (4 Nos. on each stand)
63Wind Socks
64Complete work of supply of pipes, flanges and fittings including all taxes, duties, transportation and inspection charges but not limited to, the following itemsin accordance with PMS (piping material specification), relevant specifications & drawings indicated in scope of work indicated in SCC and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT. Handling including lifting, transportation from Contractor Stores to CONTRACTOR"s workshop for fabrication and/ or to work site for field fabrication and erection for all piping items supplied by Contractor. Note: i) The quantities mentioned below are tentative. ii) For all the supply items mentioned above, procurement shall be made as per specification after due approval of Engineer-in-charge.
654" NB, BE (ASTM A106, Gr. B (Charpy), Seamless, BE)S80
662" NB, BE(ASTM A106, Gr. B (Charpy), Seamless, BE )XS XS
671" NB, BE(ASTM A106, Gr. B, Seamless, PE) XSXS
683/4" NB, BE(ASTM A106, Gr. B, Seamless, PE ) S160XS
694" NB, RF300#
702" NB, RF 300#
711"NB,RF300#
723/4" NB RF300#
734" NB, RF300#
742" NB, RF300#
751"NB,RF300#
763/4" NB RF300#
774" NB S80
782" NBXS
794" NBS80
802" NB XS
814"NB S80
822" NBXS
834"x 2"NBS80 x XS
844" x 1"NBS40 x XS
854" x ¾" NBS40 x S160
862" x 1"NB XS x XS
872" x ¾" NBXS x S160
884" NBS80
894" NB x 2" NBS80 x XS
90Complete work of supplyof valves including all taxes,duties,transportation and inspection charges but not limited to ,the following items in accordance with relevant Specifications & relevant Data Sheets indicated inscope of work indicated in SCC, drawings, specification and instructions of EIC and as perall provisions of the CONTRACT DOCUMENT.
912" NB BW 300#
924" NB BW , FB 300#
932" NBBW , FB300#
942" NB FE ,FB 300#
951" NBSW, FB 800#
96¾" NBSW, FB800#
97Complete Carbon Steel aboveground Piping Work with painting including all fittings, flanges and supply of all required gaskets, vent flappers, studs bolts & nuts etc. as described under item 1.0 above Note: 1) Pipe Specification and thickness may vary depending upon availability of pipe.No extra payment shall be made for this. 2) All butt welded fittings end shall generally match with connecting pipe wall thickness. However, in case of misalignment, Contractor shall have to do end preparation without any extra cost. 3) All coupling, nipples stud, bolts, nuts, gaskets and vent flapper etc. as required shall be suplied by contractor but no separate payments shall be made as it is covered under erection rate.
984" NB, BE (ASTM A106, Gr. B (Charpy), Seamless, BE) S80
992" NB, BE(ASTM A106, Gr. B (Charpy), Seamless, BE )XS XS
1001" NB, BE(ASTM A106, Gr. B , Seamless, PE) XS XS
1013/4" NB, BE(ASTM A106, Gr. B, Seamless, PE ) S160XS
102Performance of radiographic inspection by gamma radiation as per scope of work and as per specifications in piping of all types and thickness including providing/hiring of all necessary equipments, supply of all consumables, and whatever else even though not expressely mentioned but required to perform the work as per specifications and instructions of Engineer-in-Charge (full circle re-radiography of the repaired joint and additional radiography necessitated due to poor performance of contractor"s welder shall be carried out by the Contractor at his own cost and shall not be paid extra by Company).Radiographs shall be submitted to the Engineer-in-Charge for acceptance, whose decision shall be final and binding. Note: i) The quantities mentioned below are tentative.
1034" NB
1042" NB
105Handling including lifting and transportation from COMPANY"s warehouse to CONTRACTOR"S Stores and/or work site and installation of all types of valves, insulating joint, flow tee including assembly of valve accessories, (if any) by bolting, threading or welding, supply and insertion of gaskets, nuts & bolts, nipples, etc. at all elevations of pipe sleepers, supports or overhead on racks, equipments nozzle, skid & painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning of valve wherever requried.
1062" NBBW300#
1074" NB BW , FB300#
1082" NBBW , FB 300#
1092" NB FE ,FB300#
1101" NBSW, FB 800#
111¾" NB SW, FB800#
112Supply, installation and calibration of pressure Gauges and their accessories inclusive of supply of necessary piping materials/tubings alongwith all necessary valves & fittings, fabrication and installation of impulse lines/manifolds as per drawing and direction of engineer-in charge.
113STRUCTURAL WORKS
114Supply, fabrication and erection of all types of pipe supports like clamps, saddle, guide stops, cradles, turn buckles, anchors, T-posts; stockade/ trestle and pipe bridge for overhead piping; frames for canopy, approach ladders and platforms, crossover, cable tray supports, etc. including painting suitable for highly corrosive area as per specificationlabour and supervision & complete work as per drawings, specifications and instruction of Engineer-in-charge. (Bolts, nuts, washers, PVC coated U-clamps etc. for supporting shall be supplied by the Contractor within the rates quoted.These items will not be measured and paid seperately).The work is to be completed in all respect as per scope of work and specification. Notes: The quantities indicated above are tentative estimated values and hence are approximate. Final payment will be made based on actual quantities to be certified by the Owner/Owner representative. The cost of MS bolts (permanent and service(, washers, electrodes, putty, gases, cost of straightening the raw materials, cutting of flats from plates and providing splices, paints, tools, plants etc., as required for the work shall be deemed to be included in the quoted rates. All handling and transport charges of raw materials and fabricated structures including double handling, as required, for completion of work in accrodance with time schedule, are deemed be included in the quoted rates.
115Providing, laying in position, construction and handing over of PCC in all types of concrete works including levelling courses below foundations, mass concrete works, chambers, cable trench, under floors and any other locations(which are not covered as part of respective items of SOR), at all levels and locationsetc complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. a) PCC M-15 (1:2:4)[ 1 Cement: 2 coarse sand : 4 stone aggregate 20 mm nominal size] Note: 1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement, coarse sand and coarse aggregates, other minor construction materials, shuttering, staging, shoring/strutting, finishing, etc. with all bye works and sundry works. 2. To be read in conjunction with relevent clause of PJS.
116Conversion of DBS to Online/Mother Station
117Decommissioning of SS tubing, Dismentalling of SS tubing, providing connections with online compressor/cascade/dispenser as required including installation of fittings & relacement of damaged fittings (supply to be as per relevant SOR item) , Retesting of already laid tubings, installation of valves (supply as per relevant SOR), providing as build P&ID drawings, etc.completing all tubing/mechanical work to complete the conversion of DBS to Online station. Any fresh supply & laying of SS tubing to be paid separately as per relevant SOR item.
118Disconnecting / reconnecting all air piping/tubing , loading, transportation & unloading of compressor at designated locaation (within GA boundary),
119Disconnecting all electrical connections with booster compressor/panel/other equipment, relaying/testing of used cables if required, disconnection of earthing grid from compressor/panel/other equipment & recoonection with online compressor, repair of earth elecrodes etc. Any fresh supply and laying of cable/GI strip/earthing electrod to be paid as per relevant SOR
120Supplying and Installing Mandatory Sign made of 4mm thick. ACM (Alstrong/ Aludecor/ Alucobond) sheets cladded on structural framework. Matter/Logo in Retro Reflective Sheeting (Avery / 3M / equ.)Type XI DG3 Microprismetice as per ASTM D 4956-09 duly pasted on ACM in required size & shape, all complete with by works, as approved.
121300mm X 600mm
122Design, engineering, manufacture, shop testing, supply includingpacking and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) and Lighting Distribution Board (LDB) :
123415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Dual Incomer 125 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip)with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 80 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.
124415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Single Incomer 125 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip). Outgoing with 1 ns. 100 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB, 2 NosDP MCB of rating, 6Amp,10Amp & 16Amp
125415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & Dual Incomer 100 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip)with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 63 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.
126415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD. Single Incomer 100 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip). Outgoing with 1 no. 63 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp
127415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Dual Incomer of 400 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) and 63A 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 400 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB, Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.
128415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Single Incomer of 400 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) Outgoing with - 1 no. 400 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp
129415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Dual Incomer of 315 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) and 63A 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 250 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB, Outgoing with HRC fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.
130415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Single Incomer of 315 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) Outgoing with - 1 no. 250 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp
131Floor mounted APFC panel of 40KVAR capacitor bank in steps of 4X2.5, 4X5, 10 & 20 capacitor of MIN 10 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg
132Floor mounted APFC panel of 50KVAR capacitor bank in steps of 4X2.5, 4X5, 10 & 20 capacitor of MIN 10 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg.
133Floor mounted APFC panel of 10KVAR capacitor bank in steps of 4X2.5capacitor of 4 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg.
134Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals.
135Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 315A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 120/95 sq.mm A2XFY cable on incomer terminals andoutgoing terminals.
136Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 400A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 240/150 sq.mm A2XFY cable on incomer terminals andoutgoing terminals.
137Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals.
138Design, engineering,supply includingpacking and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
139Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover
140Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover
141GI Strip (50X6) mm
142GI Strip (25X3) mm
143GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare copper rope labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge.
144Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.
14525 sq mm green fexible copper wire(Approx 10mtrs) along with two nos Clamps harware etc shall be complete including mettalic cover box(suitable for outdoor) ,size 400X400X200 in all respect to earthing/ground of LCV at two points.
146Design, engineering,supply includingpacking and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
1473.5x 150 mm2 A2XFY
1483.5x 120 mm2 A2XFY
1493.5x 50 mm2 A2XFY
1504x 25 mm2 A2XFY
1514x10 mm2 2XWY
1524x 6 mm2 2XWY
1534x 2.5 mm2 2XWY
1542x 1.5 mm2 2XWY
155Supply includingpacking and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects.
156Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 100 W LED luminaire with flame proof control gear.
157Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 100 LED luminaire
158Supply of the underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting( BH/OA/124, 1 x LED, 150W juction boxes etc. as requried.
159Street lighting pole 6mtr high GI octagonal polecomplete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing
160Supply of point wiring as per details in construction drawing & specificationincludesPVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches , Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items-
161Light Point
162Surface/ recess mounted 18W LED light fixrure with LED lamp (type LCTL-18 -CDL )
163Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 )
164Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm.
165Socket outlet (5/15 Amp combination)
166Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
167UPS SYSTEM
168Design, supply, packing, forwarding, delivery by equipment supplier at site including commissioning spares as requiredof UPS systems as per specification, block diagram and following rating :
1693KVA, 230 V Single phase, 50 Hz, single industrial type, redundant UPS system suitable for input Power supply voltage of 320V-460V- TPN (184-265V/Ph) , output 230 V +/- 1%, AC with Bypass supply, Battery Bank ,ACDB (Incomer 32A DP MCB & Outgoing 2 Nos. 6A DP MCB & 6 nos.10A DP MCB) and 4.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 18 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). Main input transformer rating Shall not be Less than 9 KVA,As per Block diagram, Specification & Data sheet and shall be complete in all respect. .All interconnecting cables among UPS, Rectifier, battery stand, ACDB/DCDBetc (20 mtr shall be considered between battery bank and UPS panel, 20 mtr cable shall be considered between ACDB and UPS panel and any other cable which is not defined here but necessary for satisfactory operation of the UPS system).
170Supply of following sizes ofHDPE Pipein required length ,supply of clamps, small iron structures, spacersplugs, sealent etc. and materials complete as per approved drawingsand directions of Engineer-In-Charge.
17150 mm NB
172100 mm NB
173Supply of following Hot Dip Galvanized Ladder/Perforated Typecable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction ofEngineer-in-charge
174Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.
175150mm wide
176300mm wide
177Erection Material
178Supply of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
179For Mother Station(Gas Engine)
180For Mother Station(Motor)
181For ON-LINE(Motor)
182For DBS(Motor)
183Supply of the following including the supply of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.
184Shock hazard charts complete with frame and glass
185First Aid Boxes
186Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate
187Caution boards (Danger, High Volatage) including supply of necessary clamps, bolts and other hardware.
188Single Line Diagram complete in glass frame.(Size 600X800mm)
189Supply ofInsulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
190Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.
191For Mother Station(Gas Engine)
192For Mother Station(Motor)
193For ON-LINE(Motor)
194For DBS(Motor)
195Telephone & LAN
196Supply of telephone sockets(Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
197Supply of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
198Supply of 2 pairs,0.61mm,Telephone Cable/Wire, includingaccessories etc as required.
199Supply of UTP cable (CAT 6), Make : D Link/Amp/Lucent
200Erection, Testing and Commissioning of power distribution board (PDB) and Lighting Distribution Board (LDB) :
201415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD. Dual Incomer 125 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip)with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 80 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.
202415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Single Incomer 125 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip). Outgoing with 1 ns. 100 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB, 2 NosDP MCB of rating, 6Amp,10Amp & 16Amp
203415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no. Dual Incomer 100 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip)with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 63 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.
204415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no 9200-13700-40401-002-00 Single Incomer 100 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip). Outgoing with 1 no. 63 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp
205415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no. Dual Incomer of 400 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) and 63A 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 400 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB, Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.
206415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no.9200-13700-40401-002-00 Single Incomer of 400 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) Outgoing with - 1 no. 400 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp
207415 V, 36 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Dual Incomer of 315 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) and 63A 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 250 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB Outgoing with HRC fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer.
208415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no.9200-13700-40401-002-00 . Single Incomer of 315 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) Outgoing with - 1 no. 250 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp
209Floor mounted APFC panel of 40KVAR capacitor bank in steps of 4X2.5, 4X5, 10 & 20 capacitor of MIN 10 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg.
210Floor mounted APFC panel of 50KVAR capacitor bank in steps of 4X2.5, 4X5, 10 & 20 capacitor of MIN 10 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg. no.
211Floor mounted APFC panel of 10KVAR capacitor bank in steps of 4X2.5capacitor of 4 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg.
212Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals.
213Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 315A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 120/95 sq.mm A2XFY cable on incomer terminals andoutgoing terminals.
214Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 400A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 240/150 sq.mm A2XFY cable on incomer terminals andoutgoing terminals.
215Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals.
216Erection, Testing and Commissioning of complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043.
217Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover
218Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover
219GI Strip (50X6) mm
220GI Strip (25X3) mm
221GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare copper rope labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge.
222Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80.
22325 sq mm green fexible copper wire(Approx 10mtrs) along with two nos Clamps harware etc shall be complete including mettalic cover box(suitable for outdoor) ,size 400X400X200 in all respect to earthing/ground of LCV at two points.
224Laying, termination,glanding, testing of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc.
2253.5x 150 mm2 A2XFY
2263.5x 120 mm2 A2XFY
2273.5x 50 mm2 A2XFY
2284x 25 mm2 A2XFY
2294x10 mm2 2XWY
2304x 6 mm2 2XWY
2314x 2.5 mm2 2XWY
2322x 1.5 mm2 2XWY
233Erection, Testing and Commissioning of lighting fixtures,Pole complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge.Work to be completed in all respects.
234Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 100 W LED luminaire with flame proof control gear
235Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 100 W LED luminaire
236Underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting( BH/OA/124, 1 x LED, 150W)of juction boxes etc. as requried.
237Street lighting pole 6mtr high GI octagonal pole complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing
238Erection, testing & Commissioning of point wiring as per details in construction drawing & specificationincludesPVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches , Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items-
239Light Point
240Surface/ recess mounted 18W LED light fixrure with LED lamp (type LCTL-18 -CDL )
241Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 ).
242Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm.
243Socket outlet (5/15 Amp combination)
244Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting
245UPS SYSTEM
246Erection, Testing and Commissioning by equipment manufacturer at site including commissioning spares as requiredof UPS systems as per specification, block diagram and following rating :
2473KVA, 230 V Single phase, 50 Hz, single industrial type, redundant UPS system suitable for input Power supply voltage of 320V-460V- TPN (184-265V/Ph) , output 230 V +/- 1%, AC with Bypass supply, Battery Bank ,ACDB (Incomer 32A DP MCB & Outgoing 2 Nos. 6A DP MCB & 6 nos.10A DP MCB) and 4.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 18 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). Main input transformer rating Shall not be Less than 9 KVA,As per Block diagram, Specification & Data sheet and shall be complete in all respect..All interconnecting cables among UPS, Rectifier, battery stand, ACDB/DCDBetc (20 mtr shall be considered between battery bank and UPS panel, 20 mtr cable shall be considered between ACDB and UPS panel and any other cable which is not defined here but necessary for satisfactory operation of the UPS system).
248Erection of following sizes of HDPE Pipe including bend route as required length ,clamps, small iron structures, spacersplugs, sealent etc. and materials complete as per approved drawingsand directions of Engineer-In-Charge.
24950 mm NB
250100 mm NB
251Erection, Testing and Commissioning of following Hot Dip Galvanized Ladder/Perforated Typecable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including all G.I hardwares, all labour and material as required as per standard drawings, specification and direction ofEngineer-in-charge
252Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes.
253150mm wide
254300mm wide
255Erection Material
256Erection, Fixing and Commissioning of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, necessary anchor bolts and grouting etc paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge.
257For Mother Station(Gas Engine)
258For Mother Station(Motor)
259For ON-LINE(Motor)
260For DBS(Motor)
261Erection and Commissioning of the following including necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules.
262Shock hazard charts complete with frame and glass
263First Aid Boxes
264Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate
265Caution boards (Danger, High Volatage) including supply of necessary clamps, bolts and other hardware.
266Single Line Diagram complete in glass frame.(Size 600X800mm)
267Laying and pasting ofInsulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules.
268Erection,Commissioning and fixing of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge.
269For Mother Station
270For Bus Depo
271For DBS/RO/ONLINE
272For DCU
273Telephone & LAN
274Installation,testing and commissioning of telephone sockets(Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
275Installation,testing and commissioning of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required.
276Installation,testing and commissioning of 2 pairs,0.61mm,Telephone Cable/Wire, includingaccessories etc as required.
277Installation,testing and commissioning of UTP cable (CAT 6), Make : D Link/Amp/Lucent
278All works relating to statutory approvals of the installation from competent authority like Electrical Inspectorate, CEA, DGMS, SEB etc. including carrying out of all required modifications in design / Manufacturer / Installation to meet the requirement of Indian Electricity rules and other statutory regulations in force, carrying out necessary paper work and liasion with the authorities to obtain all necessary clearances for charging of installation as per relevant national standards for Mother CNG station. However the official fees towards the approvals shall be reimbursed by the client.