Indian Oil Corporation Limited-IOCL has published Rate Contract & Empanelment Of Contractors For Composite Works ( Mechanical & Electrical Works ) For Development Of Different Type Of Cng Stations At Various Geographical Areas In The States Of Punjab, Maharashtra, Rajasthan, West Bengal, And Ut Of . Submission Date for this Tender is 27-10-2022. Electromechanical Work Tenders in noida Uttar Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 17-Oct-2022 | CORRIGENDUM-1 | Technical Bid | 27-10-2022 |
Sl. No. | Item Description |
1 | GST % for this Tender Please select the rate of GST in Cell AY13. Rate selected shall be applicable for the entire BOQ. |
2 | Laying, testing and commissioning of SS tubes along with fittings as per Technical Specification, Typical P & ID for type of CNG station and scope of work, handling, lifting, transportation from stores toCNG stations. |
3 | ¾”OD X 0.095” min Wall thk.SS Tube |
4 | ½”OD X 0.083” min Wall thk.SS Tube |
5 | SUPPLY OF SS TUBES as per Technical Specification |
6 | ¾”OD X 0.095” min Wall thk.,Material SS316SS Tube |
7 | ½”OD X 0.083” min Wall thk.,Material SS316 SS Tube |
8 | Quick Connect Body & Stem |
9 | QRC of 3/8" NPT , end connection:½" Tube OD, for stem & ½”NPT (F) for body MaterialSS316; Rated pressure : 5000 PSI @ 70°F Temperature: 0°F to 400°F |
10 | Plug |
11 | Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
12 | Size : ¾" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
13 | Caps |
14 | Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
15 | Size : ¾" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
16 | Union |
17 | Size : ¾” OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
18 | Size : ½" OD, Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
19 | Reducing Union |
20 | Tube OD 3/4" x Tube OD 1/2", Material : SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
21 | Equal Tee |
22 | Size:½” OD x ½” OD x ½” OD, Material:SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
23 | Size:¾" OD x ¾" OD x ¾" OD, Material : SS316 ( Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
24 | Reducing Union Tee |
25 | ¾" OD x ½" OD x ¾" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
26 | Tube End Connection |
27 | ½” Tube End & ¾” OD with Ferrule Fitting, SS316 (Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
28 | Nut |
29 | ¾ " OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
30 | ½" OD, Material : SS316(Rated pressure : 6000 PSI @ 70°F Temperature : 0°F to 400°F) |
31 | Front Ferrule |
32 | 3/4" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
33 | ½" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
34 | Back Ferrule |
35 | 3/4" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
36 | ½" OD, Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
37 | Male Connector |
38 | Size ¼” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
39 | Size 1/2” NPT (M) x 3/8” OD, SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
40 | Cross |
41 | 3/4" OD X 3/4”X 3/4" OD X3/4" OD Material : SS316(Rated pressure : 5000 PSI @ 70°F Temperature : 0°F to 400°F) |
42 | SS Ball Valves of following sizes as indicated below as per Tender Specifications and Instruction of Engineer-In-Charge: |
43 | 2-Way Floating Normal Bore Ball Valve ¾" |
44 | 2-Way Floating Normal Bore Ball Valve ½" |
45 | 3-Way Trunnion Mounted, Reducer BoreBall Valve ½" OD end Connection and ¼” NPT (F) bottom end connection |
46 | Conductive Core Thermoplastic Hose |
47 | 3/8” ID Conductive Core Thermoplastic Hose for CNG Service with break away coupling ( 3 Meter ) |
48 | Supply , Laying, testing and commissioning of SS 304 Tubes along with isolation valves, reducers & fittings etc.as per Technical Specification, Typical schematic drg. for Ins. air line of CNG station and scope of workincluding handling, storage,lifting, transportation upto CNG stations.(Note:Total no.offerrule fittings may be considered as one jointing ferrule at every 5.0 m) |
49 | 1/4”OD X 0.035” min Wall thk.SS Tube |
50 | Handling (including lifting and transportation from Client"s store within city toCNG stations)and erecting in position, the following equipmenteither on the foundation at Ground level or on roof at 3.0 m above ground level.Contractor"s scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc. : Note: The quantities given below against individual items are indicative and shall not be considered to be binding.The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge.The unit rate shall be operated to work out the final payment due to Contractor. |
51 | Cascade 4500/3000 L water capacity. Erection at + 3.0 M level |
52 | Cascade 4500/3000 L water capacity, Erection at + Ground level |
53 | Dispenser Erection at + Ground Level |
54 | Handling (including lifting within CNG stations) and erecting in position, the following equipmenteither on the foundation at Ground level or on roof at 3.0 m above ground level.Contractor"s scope shall include supply of all material and accessories including but not limited to any fixtures, clamps, gasket, nut bolts, etc. : Note: The quantities given below against individual items are indicative and shall not be considered to be binding.The quantities may increase or decrease at site at the time of actual execution and as per the discretion of Owner/ Engineer-in-charge.The unit rate shall be operated to work out the final payment due to Contractor. |
55 | Cascade 4500/3000 L water capacity. Erection at + 3.0 M level |
56 | Cascade 4500/3000 L water capacity, Erection at + Ground level |
57 | Dispenser Erection at + Ground Level |
58 | Supply, erection & commissioning of following miscellaneous items as per technical specification and at locations (within the stations) as directed by EIC Fire fighting Equipments |
59 | DCP -10 Kg |
60 | DCP -75 Kg (trolley mounted) |
61 | CO2 – 4.5 Kg (portable) |
62 | Sand Bucket with stand and canopy (4 Nos. on each stand) |
63 | Wind Socks |
64 | Complete work of supply of pipes, flanges and fittings including all taxes, duties, transportation and inspection charges but not limited to, the following itemsin accordance with PMS (piping material specification), relevant specifications & drawings indicated in scope of work indicated in SCC and instructions of Engineer-in-charge and as per all provisions of the CONTRACT DOCUMENT. Handling including lifting, transportation from Contractor Stores to CONTRACTOR"s workshop for fabrication and/ or to work site for field fabrication and erection for all piping items supplied by Contractor. Note: i) The quantities mentioned below are tentative. ii) For all the supply items mentioned above, procurement shall be made as per specification after due approval of Engineer-in-charge. |
65 | 4" NB, BE (ASTM A106, Gr. B (Charpy), Seamless, BE)S80 |
66 | 2" NB, BE(ASTM A106, Gr. B (Charpy), Seamless, BE )XS XS |
67 | 1" NB, BE(ASTM A106, Gr. B, Seamless, PE) XSXS |
68 | 3/4" NB, BE(ASTM A106, Gr. B, Seamless, PE ) S160XS |
69 | 4" NB, RF300# |
70 | 2" NB, RF 300# |
71 | 1"NB,RF300# |
72 | 3/4" NB RF300# |
73 | 4" NB, RF300# |
74 | 2" NB, RF300# |
75 | 1"NB,RF300# |
76 | 3/4" NB RF300# |
77 | 4" NB S80 |
78 | 2" NBXS |
79 | 4" NBS80 |
80 | 2" NB XS |
81 | 4"NB S80 |
82 | 2" NBXS |
83 | 4"x 2"NBS80 x XS |
84 | 4" x 1"NBS40 x XS |
85 | 4" x ¾" NBS40 x S160 |
86 | 2" x 1"NB XS x XS |
87 | 2" x ¾" NBXS x S160 |
88 | 4" NBS80 |
89 | 4" NB x 2" NBS80 x XS |
90 | Complete work of supplyof valves including all taxes,duties,transportation and inspection charges but not limited to ,the following items in accordance with relevant Specifications & relevant Data Sheets indicated inscope of work indicated in SCC, drawings, specification and instructions of EIC and as perall provisions of the CONTRACT DOCUMENT. |
91 | 2" NB BW 300# |
92 | 4" NB BW , FB 300# |
93 | 2" NBBW , FB300# |
94 | 2" NB FE ,FB 300# |
95 | 1" NBSW, FB 800# |
96 | ¾" NBSW, FB800# |
97 | Complete Carbon Steel aboveground Piping Work with painting including all fittings, flanges and supply of all required gaskets, vent flappers, studs bolts & nuts etc. as described under item 1.0 above Note: 1) Pipe Specification and thickness may vary depending upon availability of pipe.No extra payment shall be made for this. 2) All butt welded fittings end shall generally match with connecting pipe wall thickness. However, in case of misalignment, Contractor shall have to do end preparation without any extra cost. 3) All coupling, nipples stud, bolts, nuts, gaskets and vent flapper etc. as required shall be suplied by contractor but no separate payments shall be made as it is covered under erection rate. |
98 | 4" NB, BE (ASTM A106, Gr. B (Charpy), Seamless, BE) S80 |
99 | 2" NB, BE(ASTM A106, Gr. B (Charpy), Seamless, BE )XS XS |
100 | 1" NB, BE(ASTM A106, Gr. B , Seamless, PE) XS XS |
101 | 3/4" NB, BE(ASTM A106, Gr. B, Seamless, PE ) S160XS |
102 | Performance of radiographic inspection by gamma radiation as per scope of work and as per specifications in piping of all types and thickness including providing/hiring of all necessary equipments, supply of all consumables, and whatever else even though not expressely mentioned but required to perform the work as per specifications and instructions of Engineer-in-Charge (full circle re-radiography of the repaired joint and additional radiography necessitated due to poor performance of contractor"s welder shall be carried out by the Contractor at his own cost and shall not be paid extra by Company).Radiographs shall be submitted to the Engineer-in-Charge for acceptance, whose decision shall be final and binding. Note: i) The quantities mentioned below are tentative. |
103 | 4" NB |
104 | 2" NB |
105 | Handling including lifting and transportation from COMPANY"s warehouse to CONTRACTOR"S Stores and/or work site and installation of all types of valves, insulating joint, flow tee including assembly of valve accessories, (if any) by bolting, threading or welding, supply and insertion of gaskets, nuts & bolts, nipples, etc. at all elevations of pipe sleepers, supports or overhead on racks, equipments nozzle, skid & painting etc. supply of all consumables, manpower, equipment, etc. for completion of all works as per scope of work and as per drawings, specifications and instructions of Engineer-in-charge including servicing/ cleaning of valve wherever requried. |
106 | 2" NBBW300# |
107 | 4" NB BW , FB300# |
108 | 2" NBBW , FB 300# |
109 | 2" NB FE ,FB300# |
110 | 1" NBSW, FB 800# |
111 | ¾" NB SW, FB800# |
112 | Supply, installation and calibration of pressure Gauges and their accessories inclusive of supply of necessary piping materials/tubings alongwith all necessary valves & fittings, fabrication and installation of impulse lines/manifolds as per drawing and direction of engineer-in charge. |
113 | STRUCTURAL WORKS |
114 | Supply, fabrication and erection of all types of pipe supports like clamps, saddle, guide stops, cradles, turn buckles, anchors, T-posts; stockade/ trestle and pipe bridge for overhead piping; frames for canopy, approach ladders and platforms, crossover, cable tray supports, etc. including painting suitable for highly corrosive area as per specificationlabour and supervision & complete work as per drawings, specifications and instruction of Engineer-in-charge. (Bolts, nuts, washers, PVC coated U-clamps etc. for supporting shall be supplied by the Contractor within the rates quoted.These items will not be measured and paid seperately).The work is to be completed in all respect as per scope of work and specification. Notes: The quantities indicated above are tentative estimated values and hence are approximate. Final payment will be made based on actual quantities to be certified by the Owner/Owner representative. The cost of MS bolts (permanent and service(, washers, electrodes, putty, gases, cost of straightening the raw materials, cutting of flats from plates and providing splices, paints, tools, plants etc., as required for the work shall be deemed to be included in the quoted rates. All handling and transport charges of raw materials and fabricated structures including double handling, as required, for completion of work in accrodance with time schedule, are deemed be included in the quoted rates. |
115 | Providing, laying in position, construction and handing over of PCC in all types of concrete works including levelling courses below foundations, mass concrete works, chambers, cable trench, under floors and any other locations(which are not covered as part of respective items of SOR), at all levels and locationsetc complete in all respects as per scope of work, detailed construction drawings, technical specifications and direction of Engineer-in-charge. a) PCC M-15 (1:2:4)[ 1 Cement: 2 coarse sand : 4 stone aggregate 20 mm nominal size] Note: 1. Rate to include cost of all labour, tools, tackles, equipment, hire charges, supply of all materials such as minimum 43 grade cement, coarse sand and coarse aggregates, other minor construction materials, shuttering, staging, shoring/strutting, finishing, etc. with all bye works and sundry works. 2. To be read in conjunction with relevent clause of PJS. |
116 | Conversion of DBS to Online/Mother Station |
117 | Decommissioning of SS tubing, Dismentalling of SS tubing, providing connections with online compressor/cascade/dispenser as required including installation of fittings & relacement of damaged fittings (supply to be as per relevant SOR item) , Retesting of already laid tubings, installation of valves (supply as per relevant SOR), providing as build P&ID drawings, etc.completing all tubing/mechanical work to complete the conversion of DBS to Online station. Any fresh supply & laying of SS tubing to be paid separately as per relevant SOR item. |
118 | Disconnecting / reconnecting all air piping/tubing , loading, transportation & unloading of compressor at designated locaation (within GA boundary), |
119 | Disconnecting all electrical connections with booster compressor/panel/other equipment, relaying/testing of used cables if required, disconnection of earthing grid from compressor/panel/other equipment & recoonection with online compressor, repair of earth elecrodes etc. Any fresh supply and laying of cable/GI strip/earthing electrod to be paid as per relevant SOR |
120 | Supplying and Installing Mandatory Sign made of 4mm thick. ACM (Alstrong/ Aludecor/ Alucobond) sheets cladded on structural framework. Matter/Logo in Retro Reflective Sheeting (Avery / 3M / equ.)Type XI DG3 Microprismetice as per ASTM D 4956-09 duly pasted on ACM in required size & shape, all complete with by works, as approved. |
121 | 300mm X 600mm |
122 | Design, engineering, manufacture, shop testing, supply includingpacking and forwarding, transportation, delivery at storage and from storage to site of power distribution board (PDB) and Lighting Distribution Board (LDB) : |
123 | 415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Dual Incomer 125 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip)with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 80 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer. |
124 | 415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Single Incomer 125 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip). Outgoing with 1 ns. 100 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB, 2 NosDP MCB of rating, 6Amp,10Amp & 16Amp |
125 | 415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & Dual Incomer 100 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip)with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 63 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer. |
126 | 415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD. Single Incomer 100 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip). Outgoing with 1 no. 63 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp |
127 | 415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Dual Incomer of 400 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) and 63A 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 400 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB, Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer. |
128 | 415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Single Incomer of 400 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) Outgoing with - 1 no. 400 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp |
129 | 415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Dual Incomer of 315 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) and 63A 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 250 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB, Outgoing with HRC fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer. |
130 | 415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Single Incomer of 315 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) Outgoing with - 1 no. 250 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp |
131 | Floor mounted APFC panel of 40KVAR capacitor bank in steps of 4X2.5, 4X5, 10 & 20 capacitor of MIN 10 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg |
132 | Floor mounted APFC panel of 50KVAR capacitor bank in steps of 4X2.5, 4X5, 10 & 20 capacitor of MIN 10 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg. |
133 | Floor mounted APFC panel of 10KVAR capacitor bank in steps of 4X2.5capacitor of 4 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg. |
134 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals. |
135 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 315A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 120/95 sq.mm A2XFY cable on incomer terminals andoutgoing terminals. |
136 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 400A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 240/150 sq.mm A2XFY cable on incomer terminals andoutgoing terminals. |
137 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals. |
138 | Design, engineering,supply includingpacking and forwarding, transportation, delivery at storage, of the complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043. |
139 | Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover |
140 | Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover |
141 | GI Strip (50X6) mm |
142 | GI Strip (25X3) mm |
143 | GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare copper rope labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge. |
144 | Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80. |
145 | 25 sq mm green fexible copper wire(Approx 10mtrs) along with two nos Clamps harware etc shall be complete including mettalic cover box(suitable for outdoor) ,size 400X400X200 in all respect to earthing/ground of LCV at two points. |
146 | Design, engineering,supply includingpacking and forwarding, transportation, delivery at storage, of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc. |
147 | 3.5x 150 mm2 A2XFY |
148 | 3.5x 120 mm2 A2XFY |
149 | 3.5x 50 mm2 A2XFY |
150 | 4x 25 mm2 A2XFY |
151 | 4x10 mm2 2XWY |
152 | 4x 6 mm2 2XWY |
153 | 4x 2.5 mm2 2XWY |
154 | 2x 1.5 mm2 2XWY |
155 | Supply includingpacking and forwarding, transportation, delivery at storage of lighting fixtures complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge. Work to be completed in all respects. |
156 | Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 100 W LED luminaire with flame proof control gear. |
157 | Supply of Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 100 LED luminaire |
158 | Supply of the underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting( BH/OA/124, 1 x LED, 150W juction boxes etc. as requried. |
159 | Street lighting pole 6mtr high GI octagonal polecomplete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing |
160 | Supply of point wiring as per details in construction drawing & specificationincludesPVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches , Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items- |
161 | Light Point |
162 | Surface/ recess mounted 18W LED light fixrure with LED lamp (type LCTL-18 -CDL ) |
163 | Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 ) |
164 | Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm. |
165 | Socket outlet (5/15 Amp combination) |
166 | Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting |
167 | UPS SYSTEM |
168 | Design, supply, packing, forwarding, delivery by equipment supplier at site including commissioning spares as requiredof UPS systems as per specification, block diagram and following rating : |
169 | 3KVA, 230 V Single phase, 50 Hz, single industrial type, redundant UPS system suitable for input Power supply voltage of 320V-460V- TPN (184-265V/Ph) , output 230 V +/- 1%, AC with Bypass supply, Battery Bank ,ACDB (Incomer 32A DP MCB & Outgoing 2 Nos. 6A DP MCB & 6 nos.10A DP MCB) and 4.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 18 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). Main input transformer rating Shall not be Less than 9 KVA,As per Block diagram, Specification & Data sheet and shall be complete in all respect. .All interconnecting cables among UPS, Rectifier, battery stand, ACDB/DCDBetc (20 mtr shall be considered between battery bank and UPS panel, 20 mtr cable shall be considered between ACDB and UPS panel and any other cable which is not defined here but necessary for satisfactory operation of the UPS system). |
170 | Supply of following sizes ofHDPE Pipein required length ,supply of clamps, small iron structures, spacersplugs, sealent etc. and materials complete as per approved drawingsand directions of Engineer-In-Charge. |
171 | 50 mm NB |
172 | 100 mm NB |
173 | Supply of following Hot Dip Galvanized Ladder/Perforated Typecable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including supply of all G.I hardwares, all labour and material as required as per standard drawings, specification and direction ofEngineer-in-charge |
174 | Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes. |
175 | 150mm wide |
176 | 300mm wide |
177 | Erection Material |
178 | Supply of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, supply of necessary anchor bolts and grouting etc supply of paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including supply of all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge. |
179 | For Mother Station(Gas Engine) |
180 | For Mother Station(Motor) |
181 | For ON-LINE(Motor) |
182 | For DBS(Motor) |
183 | Supply of the following including the supply of necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules. |
184 | Shock hazard charts complete with frame and glass |
185 | First Aid Boxes |
186 | Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate |
187 | Caution boards (Danger, High Volatage) including supply of necessary clamps, bolts and other hardware. |
188 | Single Line Diagram complete in glass frame.(Size 600X800mm) |
189 | Supply ofInsulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules. |
190 | Supply of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge. |
191 | For Mother Station(Gas Engine) |
192 | For Mother Station(Motor) |
193 | For ON-LINE(Motor) |
194 | For DBS(Motor) |
195 | Telephone & LAN |
196 | Supply of telephone sockets(Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required. |
197 | Supply of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required. |
198 | Supply of 2 pairs,0.61mm,Telephone Cable/Wire, includingaccessories etc as required. |
199 | Supply of UTP cable (CAT 6), Make : D Link/Amp/Lucent |
200 | Erection, Testing and Commissioning of power distribution board (PDB) and Lighting Distribution Board (LDB) : |
201 | 415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD. Dual Incomer 125 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip)with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 80 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer. |
202 | 415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Single Incomer 125 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip). Outgoing with 1 ns. 100 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB, 2 NosDP MCB of rating, 6Amp,10Amp & 16Amp |
203 | 415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no. Dual Incomer 100 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip)with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with 2 nos. 63 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer. |
204 | 415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no 9200-13700-40401-002-00 Single Incomer 100 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip). Outgoing with 1 no. 63 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE with U/V Protection for Booster feeder only) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp |
205 | 415 V, 30 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no. Dual Incomer of 400 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) and 63A 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 400 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB, Outgoing with fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer. |
206 | 415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no.9200-13700-40401-002-00 Single Incomer of 400 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) Outgoing with - 1 no. 400 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp |
207 | 415 V, 36 KA single front Floor mounted type indoor PDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD Dual Incomer of 315 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) and 63A 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) with Electrical insterlock(Auto/Mannual) by Power Contactors ,Start/Stop push button with adjustable NO/NC. Outgoing with - 2 nos. 250 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -3 nos. 32 Amp TPN MCB Outgoing with HRC fuse 3 Nos. DP MCB 10 Amp with Timer(24Hrs) Auto/Mannual and with fuse 3 Nos. DP MCB 10 Amp without timer. |
208 | 415 V, 30 KA single front Floor mounted type indoor EDB to receive input power at CNG Station consisting ofbus bar chamber, cable alley,complete with wiring, indication lamp, ammeter, voltmeter, MFM (Multi Function Meter) etc including all labour and materials with operating mechanism, all accessories, mandatory spares as per data sheet, auxiliariesetc complete in all respects as specified in technical specification, data sheet & SLD no.9200-13700-40401-002-00 . Single Incomer of 315 Amp 4P MCCB (with Micro processor and based O/C,S/C & E/F RELASE with LSIG & Shunt trip) Outgoing with - 1 no. 250 Amp 4P MCCB (with TM based O/C,S/C & E/F RELASE) Outgoing with HRC Fuses -4 nos. 32 Amp TPN MCB Outgoing with HRC fuses -2Nos DP MCB of rating-6 Amp,10 Amp & 16 Amp |
209 | Floor mounted APFC panel of 40KVAR capacitor bank in steps of 4X2.5, 4X5, 10 & 20 capacitor of MIN 10 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg. |
210 | Floor mounted APFC panel of 50KVAR capacitor bank in steps of 4X2.5, 4X5, 10 & 20 capacitor of MIN 10 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg. no. |
211 | Floor mounted APFC panel of 10KVAR capacitor bank in steps of 4X2.5capacitor of 4 nos, consisting ofbus bar chamber, cable alley, incoming(FSU),all outgoing feeder(FSUs) as specified in tender drg. |
212 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 125A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals. |
213 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 315A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 120/95 sq.mm A2XFY cable on incomer terminals andoutgoing terminals. |
214 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 400A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 240/150 sq.mm A2XFY cable on incomer terminals andoutgoing terminals. |
215 | Outdoor type dust & weather proof sheet steel (2 mm thick) enclosed MCCB of following rating for mounting on wall or pedestal. 100A, 415V, 3 Pole & Neutral AC-23 duty and suitable for termination of 3.5 x 95/50 sq.mm A2XFY cable on incomer terminals andoutgoing terminals. |
216 | Erection, Testing and Commissioning of complete earthing and lightning protection system, earth electrodes/ pit, earth main ring, earthing of electrical equipments, instrument panels, field instruments, process equipments and pipes/ flanges including all associated civil work with all material (Like Bitumen coating) and labour as per specification and drawings approved by the company in with IS 3043. |
217 | Earth Pits- GI PIPE Electrode with 6 mm thick chequered plate cover |
218 | Earth Pits- Copper plate Electrode with 6 mm thick chequered plate cover |
219 | GI Strip (50X6) mm |
220 | GI Strip (25X3) mm |
221 | GI lightning rod 25 mm dia. 1800 mm long including supply of all hardware bare copper rope labour etc. complete as per approved drawings, specifications and directions of Engineer-In-Charge. |
222 | Advance maintenance free earthing system with 3mtr earth electrode of low carbon steel with 250 micron copper coating with carbon based backfill compound as per IS 3043/IEEE-80. |
223 | 25 sq mm green fexible copper wire(Approx 10mtrs) along with two nos Clamps harware etc shall be complete including mettalic cover box(suitable for outdoor) ,size 400X400X200 in all respect to earthing/ground of LCV at two points. |
224 | Laying, termination,glanding, testing of the 1.1kV grade XLPE insulated, PVC sheathed, FRLS power and control cables (conforming to IS:7098 and specification) of following sizes in trenches/ excavated under ground trench /trays, pulling through pipes and its proper sealing, cutting of paved area, roads etc. |
225 | 3.5x 150 mm2 A2XFY |
226 | 3.5x 120 mm2 A2XFY |
227 | 3.5x 50 mm2 A2XFY |
228 | 4x 25 mm2 A2XFY |
229 | 4x10 mm2 2XWY |
230 | 4x 6 mm2 2XWY |
231 | 4x 2.5 mm2 2XWY |
232 | 2x 1.5 mm2 2XWY |
233 | Erection, Testing and Commissioning of lighting fixtures,Pole complete with mounting bracket, flame proof/non flame proof, control gear box as per the type of fixture, lamps etc. including civil work with pipe inserts for cables and connecting work, with all material and labour as per specifications, drawings and instruction of Engineer-in-charge.Work to be completed in all respects. |
234 | Street lighting, integral flame proof well glass fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 100 W LED luminaire with flame proof control gear |
235 | Integral flame proof Flood Light fixture (CMIFR approved for Zone-1/2 gas group IIA & IIB) with 100 W LED luminaire |
236 | Underlights for the canopy as specified including lighting fixture flame proof enclosure for Bulk Head Fitting( BH/OA/124, 1 x LED, 150W)of juction boxes etc. as requried. |
237 | Street lighting pole 6mtr high GI octagonal pole complete with bracket, GI clamps for fixing flame proof control gear box as per standard drawing |
238 | Erection, testing & Commissioning of point wiring as per details in construction drawing & specificationincludesPVC conduits in ceiling, complete wiring including flexible wire (FR PVC), switch boxes & switches , Multi strand Flexible HR PVC insulated copper conductor wires/cables for following items- |
239 | Light Point |
240 | Surface/ recess mounted 18W LED light fixrure with LED lamp (type LCTL-18 -CDL ) |
241 | Industrial Flame proof fluorescent lamp/LED fitting with lamp (type EXTL 240 ). |
242 | Flame Proof (CMIFR approved) 12" Exhaust Fan.0.25HP motor,1440 rpm. |
243 | Socket outlet (5/15 Amp combination) |
244 | Wall mounted fan with electronic regulator ( Energy efficent, 50W,) etc complete in all respect for wall mounting |
245 | UPS SYSTEM |
246 | Erection, Testing and Commissioning by equipment manufacturer at site including commissioning spares as requiredof UPS systems as per specification, block diagram and following rating : |
247 | 3KVA, 230 V Single phase, 50 Hz, single industrial type, redundant UPS system suitable for input Power supply voltage of 320V-460V- TPN (184-265V/Ph) , output 230 V +/- 1%, AC with Bypass supply, Battery Bank ,ACDB (Incomer 32A DP MCB & Outgoing 2 Nos. 6A DP MCB & 6 nos.10A DP MCB) and 4.0 hrs. Battery backup (VRLA, 12V) and battery capacity shall not be less than 18 KVAh (where KVAH = battery AH x 12 V x No. of Batteries). Main input transformer rating Shall not be Less than 9 KVA,As per Block diagram, Specification & Data sheet and shall be complete in all respect..All interconnecting cables among UPS, Rectifier, battery stand, ACDB/DCDBetc (20 mtr shall be considered between battery bank and UPS panel, 20 mtr cable shall be considered between ACDB and UPS panel and any other cable which is not defined here but necessary for satisfactory operation of the UPS system). |
248 | Erection of following sizes of HDPE Pipe including bend route as required length ,clamps, small iron structures, spacersplugs, sealent etc. and materials complete as per approved drawingsand directions of Engineer-In-Charge. |
249 | 50 mm NB |
250 | 100 mm NB |
251 | Erection, Testing and Commissioning of following Hot Dip Galvanized Ladder/Perforated Typecable trays (as per IS 2629) including bends, tee, crosses,horizontal and vertical splices along with cable tray cover(Wherever required for Asthetic look ) etc. as required including all G.I hardwares, all labour and material as required as per standard drawings, specification and direction ofEngineer-in-charge |
252 | Perforated type, made from 50mm height and 2.5 mm thick sheet steel & galvanized (86 microns) of following sizes. |
253 | 150mm wide |
254 | 300mm wide |
255 | Erection Material |
256 | Erection, Fixing and Commissioning of MS base frame support for switch gear and bracket for misc. electrical equipment,cable tray support out of roled MS section,pipes,plates etc including welding, bolting, reveting, necessary anchor bolts and grouting etc paints applying one coat of anti rust primer two finish coats of approved synthetic enamel paints including bracking walls, floors etc for structure as required including all GI hardware materials including all labour and materials complete as required and the direction of Engineer-in-charge. |
257 | For Mother Station(Gas Engine) |
258 | For Mother Station(Motor) |
259 | For ON-LINE(Motor) |
260 | For DBS(Motor) |
261 | Erection and Commissioning of the following including necessary clamp, bolts, rawl plugs etc. breaking and making good of walls, if required , and including all labour and materials complete as per directions of Engineer-In-Charge, applicable standards and Indian Electricity rules. |
262 | Shock hazard charts complete with frame and glass |
263 | First Aid Boxes |
264 | Carbon-di-oxide(CO2) type fire extinguisher 4.5 Kg capacity Complete with gunmetal valve conforming to IS : 3224 With ISI mark , Discharge horn with bend & wall fixing Bracket With Mfg. Test certificate |
265 | Caution boards (Danger, High Volatage) including supply of necessary clamps, bolts and other hardware. |
266 | Single Line Diagram complete in glass frame.(Size 600X800mm) |
267 | Laying and pasting ofInsulating Mats 11kV grade (as per IS:15652 - 2006) of 1000mm width, required for maintenance of electrical equipment in substation as required including cutting to required shape in running length and including all labour and materials etc. complete and as per directions of Engineer-In-Charge as per applicable Indian or International standards and Indian Electricity Rules. |
268 | Erection,Commissioning and fixing of electrical accessories including, cable tags, cable tie ,Flexible pvc conduit,cable marker, nickle plated lugs, double compressed brass cable glands,brass adaptar/reducers/nipples, fixing of metallic anchor fasteners for supporting of cable trays and misc. electrical switchgear including all labour and materials complete as required and as per directions of Engineer-In-Charge. |
269 | For Mother Station |
270 | For Bus Depo |
271 | For DBS/RO/ONLINE |
272 | For DCU |
273 | Telephone & LAN |
274 | Installation,testing and commissioning of telephone sockets(Piano reed Type) in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required. |
275 | Installation,testing and commissioning of LAN sockets in recess PVC conduit including PVC conduit,telephone socket,cable,accessories etc as required. |
276 | Installation,testing and commissioning of 2 pairs,0.61mm,Telephone Cable/Wire, includingaccessories etc as required. |
277 | Installation,testing and commissioning of UTP cable (CAT 6), Make : D Link/Amp/Lucent |
278 | All works relating to statutory approvals of the installation from competent authority like Electrical Inspectorate, CEA, DGMS, SEB etc. including carrying out of all required modifications in design / Manufacturer / Installation to meet the requirement of Indian Electricity rules and other statutory regulations in force, carrying out necessary paper work and liasion with the authorities to obtain all necessary clearances for charging of installation as per relevant national standards for Mother CNG station. However the official fees towards the approvals shall be reimbursed by the client. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail