| 1 | Earth work in hard soil or gravelly soil within 50m. Initial lead and 1.5m. Initial lift including rough dressing and breaking clods to maximum 5cm.to 7cm. and laying in layers not exceeding 0.3 m. in depth asper direction of the Engineer-in-charge. |
| 2 | Supplying filling in foundation with clean coarse river sand including watering & ramming cost & conveyance of all materials, labours & T&P all respect. (Measurement will be taken for finished compacted section only) cost and conveyance of all materials labours all taxes T&P etc all complete as per the direction Engineer in charge. |
| 3 | Cement concrete (1:4:8) in foundation/floor bed concreteusing 40 mm & belowsize b.h.c.b granite stone metal of approved quality from approved quarry including lowering laying concrete watering ramming &curing etc compacting to requiredlevel laid in layers not exceeding 4’’ thick including cost conveyance all taxes royalty &cost of all material & labours T&P required for the works etc complete in all respects as per the direction of Engineer in Charge |
| 4 | Flyash brick masonry work in cm (1:6) using Flyash brick size (25 x 12 x 8)cm having minimum crushing strength not less than 75 kg /cm2 after immersing the bricks for six hour in water before use in Foundation and Plinth including splays cutting & circular molding hoisting watering curing etc with cost conveyance taxes royalty of all materials & cost of all labours T&P for the work in all respect as per clause 1300 of MORT&H specification (5th Revision) and direction of Engineer in charge. |
| 5 | R.C.C. work of M 30 using 20mm and down graded hard granite Crusher broken chips including laying, hoisting, Centring & shuttering with all cost, conveyance etc. complete. |
| 6 | Plinth Beam |
| 7 | Lintel (GF) |
| 8 | Chajja (GF) |
| 9 | Roof Beam/Wall Beam (GF) |
| 10 | Roof Slab (GF) |
| 11 | Cutting ,straightening of steel HYSD (Fe- 415) conforming to (IS- 1786) withbending, binding, cranking, hooking, welding or jointing if necessary & tying the grills and placing in positionas required for the Rod work in all floors and & for1 providing fan hooks hosting lowering ,& laying steels including cost conveyance ,taxes & royalties of allmaterials and binding wires of 18 to 20 gauge & cost of all labourT&P required for the work etc. Complete in all respect as per the direction of Engineer in charges ( payment will be made on weight of MS rod or tersteel only basing on the co- efficient of MS rod or tor steel bars approvedby SAIL/ TATA/competent authority and (Noseparate payment will be made towards the cost of binding wires over lapping, wastage, coupling, welded, joints , spacer bars, ,chairs stays, hangers and annealed steel wires or other methods for binding and placing etc.) |
| 12 | Flyash brick masonry work in cm (1:6) using Flyash brick size (25 x 12 x 8)cm having minimum crushing strength not less than 75 kg /cm2 after immersing the bricks for six hour in water before use in Foundation and Plinth including splays cutting & circular molding hoisting watering curing etc with cost conveyance taxes royalty of all materials & cost of all labours T&P for the work in all respect as per clause 1300 of MORT&H specification (5th Revision) and direction of Engineer in charge. |
| 13 | 6 mm thick Cement Plaster with cement mortar (1:4) over RCC surface including deep chiping &including all cost, conveyance, taxes, royalities etc. complete as directed by the Engineer-in-charge.specification. |
| 14 | 16 mm thick cement plaster in C.M.(1:6) finished smooth to brick walls after racking out the joints including watering curing with cost conveyance taxes & royalty of all materials & cost of all labour T&P required for the work etc complete in all respect as per the direction of Engineer in charges |
| 15 | 12 mm thick cement plaster in C.M.(1:6)to wall surface including watering curing with cost conveyance taxes & royalty of all materials & cost of all labour T&P required for the work etc complete in all respect as per the direction of Engineer in charges |
| 16 | Supplying and fixing of MS grill gateincluding cost of all material, cost of welding rod with all labour, conveyance, fixing in position etc complete as per direction of the Engineer-in-charge as per approved specification |
| 17 | Fixing wall tiles in toilet ( 20 cm x 30 cm printed glazed ceramic wall tiles thickness 6.5 mm to 6.7 mmconforming to IS 13753 on 12 mm thick bed of cement mortar 1:3 |
| 18 | Vetrified tile Flooring withcement slurry and fixing in flooring on 25mm thick bed of cement mortar (1:1) mix and joints filled with gray cement slurry etc complete in all respect as per the direction of the Engineer-in-charge. |
| 19 | Factory made single leaf rigid FRP (allernately called GRP) sandwich composite door shutter of 32mm thick laminated with two GRP skins with wood grain finish fabricated using UV-stabllised Isopthalic Gelcote and one layer of 450 gsm E-glass Chopped Strand Mal (CSM) mpregnated with orthopthalic polyester. |
| 20 | Applying two coats of distempering to wall surface with distemper of approved shade on new work to give an even shade over a coat of oil bound cement primerincludingcost & conveyance of allmaterials, taxes T& P taxes etc all complete as per the direction of Engineer-in –charge.( BERGER/ SALIMAR/ASIAN paints to be used.) |
| 21 | Applying two coats of white washing to ceiling surface with good quality shell lime by means of brush with blue and glue after scapping and cleaning the surface including scaffolding, etc. complete with cost conveyance, taxes of all the materials labours brush T&P etc. required for the work complete in all as per the direction of Engineer in charge. |
| 22 | Applying two coats of weather coatseal paint over one coat of primer the surface including curing scaffolding cost, conveyance royalty & taxes of all materials & cost of all labour ,T&P etc required for the work complete in all respect as per the direction of Engineer in charge(BERGER/ SALIMAR/ ASIAN/ JOHNSON/Nerolac paints to be used.) |
| 23 | Painting two coats with Synthetic enamel paint of approved shade & make to wood work and iron work apter primer one coat including sand papering , polishing the surface with cost ,conveyance , taxes of all materials ,labour, T&Pbrush& scaffolding charges etc . required for the work complete in all respect (paints & primer of Berger / Asian / JHONSON & Nicolson/Nerolac) as per the direction of Engineer in charge. |
| 24 | 25 mm (1’’) average thick A.S flooring with CC(1:2:4), with neat cement punning in all floors using b.h.c.b granite chips of approved quality from approved quarry 6mm to 20mm size (20 mm size not to exceed 25%) laid in proper slope & level in two layers, bottom layer being ¾ ‘’ thick & top layer ¼’’ thick using 6mm size b.h.c.b granite chips in blocks of 2.5mtrs x2.5mtrs with glass panels including chipping, chiseling, cleaning the floor rounding the corners, polishing , watering, and curingwith cost, conveyance, taxes and royalties of all materials and alllabour , T&P with side centering, required for the work etc complete as per the direction of Engineer-in-Charge. |
| 25 | Supplying all materials , labours , taxes and tools and plants for fitting and fixing of CPVC pipes of 100% lead free and conforming to ASTM F442 Specific-2 CPVC(Finolex/ SUPREME/ Astral)orEquivalent with good quality including fittings and laying as per the site requirement etc., all complete including testing as per the directionof Engineer-in-charge. |
| 26 | 20mm dia CPVC pipe |
| 27 | 40 mm dia CPVC |
| 28 | Supplying all materials, labour, T&P and cutting holes through existing brick or laterite masonry wall for takingPVC Pipes and fittings including making good the damages etc.all complete as per P.H. Specification and direction of the Engineer in charge. |
| 29 | 250 mm thick wall |
| 30 | Supplying all materials, labour, T & P and cutting grooves in pucca floors and walls for taking GI / PVC pipes and making good the damages as per the direction of the department. |
| 31 | Supplying all materials, labour, T & P and fitting and fixing brass / CP fittings of the following nominal bore with supply of all jointing materials complete as per specification and direction of the department. |
| 32 | 15 mm dia CP Angle Stop Cock |
| 33 | 100 mm dia C P Grating |
| 34 | 15 mm dia CP Pillar Cock |
| 35 | 15 mm dia CP Sink Cock |
| 36 | 15 mm dia CP Bib Cock (Short Body) |
| 37 | 15 mm dia CP Bib Cock (Long Body) |
| 38 | 40 mm dia PVC Full Way Valve |
| 39 | 5mm dia CP Concealed Stop Cock |
| 40 | 15mm dia CP Shower |
| 41 | Supplying all materials ,labour ,T&P and fitting & fixingSWR PVC pipe)and fittings of the following outside diameter conforming to ISI No13592/1992 to walls with nails ,bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber trenches including jointing with supply of approved rubber lubricant by non heat application method /as per manufacturer specification |
| 42 | 110 mm dia PVC SWR pipe |
| 43 | 110 mm dia PVCdoor tee |
| 44 | 110 mm dia PVC door bend |
| 45 | 110 mm dia PVC \"P\" trap |
| 46 | 110 mm dia PVCcowl |
| 47 | 110 mm dia PVCplain bend |
| 48 | Fixing water closet, squatting pan (Indian type W.C pan)conforming to IS 2556 : Part 3-2004 duly embedded in cement concrete (1:4:8) using hard granite metal 4cm nominal size all complete as per specification (jaquar/Hindware/Cera/Parryware). |
| 49 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. |
| 50 | Providing and fixing whitevitreous chinawash basin withFull pedestal of size 560x430x185 mm including fittings such as basin waste,connecting pipe and brasswaste, cutting and making good the walls wherever require &complete.(jaquar/Hindware/Cera/Parryware) |
| 51 | Supplying all materials ,labour ,T&P and fixing mirror of superior glass conforming to Is-3438-1996 as directed by the E-I-C.(size-1200x450) |
| 52 | supplying all materials,labour,T&P and fixing standard sized CP towel rail complete with CP brass brackets(jaquar//Hindware/Cera/Parryware. |
| 53 | Supplying all materials ,labour T&P and fixing CP soap holder completewith CP screws as per specification & direction of the E-I-C(jaquar/Equivalent) |
| 54 | Fixing standard sized glass-shelf with Chromium Plated brass brackets and guard rails complete, fixed to woden plugs with Chromium Plated brass screws as per specification. |
| 55 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I brackets and stainless steel plug 40 mm,sink waste, including painting of fittings and brackets, cutting and making good the walls wherever required. |
| 56 | Fixing Rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS : 12701--1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc, including hoisting upto a height of 5 metres above ground level and placing the tank to the required position etc all complete as per specification and direction of the Engineer in charge(1000ltrs). |
| 57 | Wiring for light point/ fan point/ exhaust fan/wall fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box including supplying the same and earthing the point with 1.5 sq.mm. FR PVC insulated copper conductor single core cable etc as required. |
| 58 | ( First Point) Group A |
| 59 | (First Point) Group B |
| 60 | (First Point) Group C |
| 61 | Calling Bell Point-(Group A) |
| 62 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required |
| 63 | 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire for 6A PP looping |
| 64 | 2 X 2.5 sq. mm + 1 X 1.5 sq. mm earth wire for 15A PP & Switch Boards & Computer points |
| 65 | 2 X 4.0 sq. mm + 1 X 2.5 sq. mm earth wire for AC Point |
| 66 | Supplying and drawing following pair 0.5 sq mm FR PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 67 | 2 Pair |
| 68 | Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 69 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 70 | 20 mm |
| 71 | 25 mm |
| 72 | 32 mm |
| 73 | Supplying and fixing metal box of 1.63 mm thick following sizes (nominal size) on surface or in recess without cover including cutting the wall and making good the same in case of recessed conduit,also including painting etc as required. |
| 74 | 75 mm X 75 mm X 60 mm deep |
| 75 | 100 mm X 100 mm X 60 mm deep |
| 76 | 150 mm X 75 mm X 60 mm deep |
| 77 | 200 mm X 125 mm X 60 mm deep |
| 78 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. |
| 79 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 2nos 3 pin 5/6 amps modular socket outlet with 2nos5/6 amps modular switch, connection etc. as required. |
| 80 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 81 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 amps modular switch, connection etc. as required. |
| 82 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25 amps modular Socket , connection etc. as required. |
| 83 | Supplying and fixing of Telephone socket out let with suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing , connection etc. as required. |
| 84 | Supplying and fixing of TV antenna socket out let with suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing , connection etc. as required. |
| 85 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 86 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required. |
| 87 | Installation, Testing and Commissioning of resistance type ceiling fan regulator, in existing box including connection with 1.5 sq.mm FR PVC insulated single core multistrand copper conductor, earthing the regulator as required. |
| 88 | Supplying and fixing following way, horizontal type single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 89 | 12way SPNDouble door |
| 90 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 91 | Single pole |
| 92 | Single pole & Neutral |
| 93 | Supplying the following Size PVC/ XLPE insulated PVC seathed Alluminium unaromour cable of 1.1 kV as per IS 1554 etc as reqd. |
| 94 | a- 2 core 6 sq.mm |
| 95 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. |
| 96 | Upto 25 sq. mm |
| 97 | Earthing with G.I earth pipe 3 meter long 40 mm dia ISI marked including accessories and providing masonary enclosure with cover plate having locking arrangment and watering pipe etc with charcoal and salt as required |
| 98 | Supplying and laying 6 SWG G.I. wires ISI marked at 0.5 meter below grond level for conductor earth electrode including soldering etc. as required |
| 99 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required |