Work For Releasing Of Ht And Lt New Service Connections In 33 / 11 Kv S / S Manpur And Pakkakot Under Edsd, Kashipur ( Town ) Under The Head Nsc ( Capital Plan ) .- 1 Decentralized Material 2 Supply Of Aluminum Crimping Lugs Of Size 25, kashipur-Uttarakhand

Uttarakhand Power Corporation Limited-UPCL has published Work For Releasing Of Ht And Lt New Service Connections In 33 / 11 Kv S / S Manpur And Pakkakot Under Edsd, Kashipur ( Town ) Under The Head Nsc ( Capital Plan ) .- 1 Decentralized Material 2 Supply Of Aluminum Crimping Lugs Of Size 25. Submission Date for this Tender is 22-11-2022. Road Work Tenders in kashipur Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

34259094
Corrigendum : Work For Releasing Of Ht And Lt New Service Connections In 33 / 11 Kv S / S Manpur And Pakkakot Under Edsd, Kashipur ( Town ) Under The Head Nsc ( Capital Plan ) .- 1 Decentralized Material 2 Supply Of Aluminum Crimping Lugs Of Size 25
Open Tender
Indian
Uttarakhand
kashipur
22-11-2022

Tender Details

Work For Releasing Of Ht And Lt New Service Connections In 33 / 11 Kv S / S Manpur And Pakkakot Under Edsd, Kashipur ( Town ) Under The Head Nsc ( Capital Plan ) .- 1 Decentralized Material 2 Supply Of Aluminum Crimping Lugs Of Size 25 Sq.Mm. 3 Supply Of Aluminum Crimping Lugs Of Size 70 Sq.Mm. 4 Supply Of Aluminum Crimping Lugs Of Size 95 Sq.Mm. 5 Supply Of Aluminum Crimping Lugs Of Size 120 Sq.Mm. 6 Supply Of Lt Clamp With N&B Pcc Pole 8.5Mtr. Long ( Ms Flat 50X6mm & 18M Dia Hole For 16X65mm Nut & Bolt As Per Respo Specification ) 7 Supply Of Stay Clamp With N&B Pcc Pole 8.5Mtr.Long ( Ms Flat 50X6mm & 18M Dia Hole For 16X65mm Nut & Bolt As Per Respo Specification ) 8 Supply Of Stay Clamp With N&B St Pole Sp-33 ( Ms Flat 65X8mm ) 9 Supply Of Stay Clamp With N&B St Pole Sp-55 ( Ms Flat 65X8mm ) 10 Supply Of Lt Shackle Insulator With One Nonut Bolt 150X16mm Made Of Best Quality Pore Line And Without Defeets Isi Standard As Per Upcl Specification. 11 Supply Of Stay Insulator 90X65 Mm. 12 Supply Of Holding Clamp With N&B Pcc Pole 8.5Mtr Long ( Ms Flat 50X6mm & 18M Dia Hole For 16X65mm Nut & Bolt As Per Respo Specification ) 13 Supply Of All Type Pp & Clamp With Nut & Bolt ( As Per Respo Specification ) 14 Supply Of F-Clamp For 11Kv Pcc Pole Line Made Of Flat 65X6mm With N&B. 15 Supply Of Dead End Clamps With I-Hook. ( As Per Specification & Drawing Of Upcl ) 16 Supply Of Suspension Clamps With I-Hook. ( As Per Specification & Drawing Of Upcl ) 17 Holding Clamp For Dead End Clamp Suitable For Ab Cable ( As Per Specification & Drawing Of Upcl ) 18 Holding Clamp For Suspension Clamp Suitable For Ab Cable ( As Per Specification & Drawing Of Upcl ) 19 Supply Of Lt Insulated Pearcing Connector 120 / 95 To 120 / 95 Mm. ( For Line To Line ) ( As Per Specification & Drawing Of Upcl ) 20 Supply Of Lt Insulated Pearcing Connector 120 / 95 To 25 / 15 Mm. ( For Line To Line ) ( As Per Specification & Drawing Of Upcl ) 21 Supply Of Lt Insulated Pearcing Connector 25 / 15 To 25 / 15 Mm. ( For Line To Line ) ( As Per Specification & Drawing Of Upcl ) 22 Supply Of L.T. Bare Neutral Connectors Pg Clamp 95Sq Mm To 25 Sq Mm. ( For Line To Line ) ( As Per Specification & Drawing Of Upcl ) 23 Labour Charges 24 Cartage Of St Pole And Pcc Poles From Store Centre To Construction Site With Loading, Unloading At Both Points. ( Loading, Unloading Pluse Carriage Per Pole ) And Proper Stacking, Cartage Of Other Material ( Other Than Poles ) By Vehicle Fro Store Center To Nearest Construction Site Store Including Loading And Unloading At Both Ends & Cartage Of The Following Capacity Transformers From Store Center To Construction Site With Loading And Unloading At Both Points. ( Loading, Unloading Plus Carriage Of T / F ) ( 0-20 Km ) 25 Sp-21 / 23 26 Sp-33 27 Sp-55 28 Sp-72 29 Pccpoles 30 Other Material In Weight 31 25 Kva 32 63 Kva 33 100 Kva 34 11Kv Vcb ( I / C, O / G ) Bus Cupler, Pannels 35 33Kv Vcb, Feeder Pannels ( O / D ) , T / F Control Pannel 36 33 / 11 Ct / Pt / Isolator 37 Headload Cartage Of Following Poles From Road To Site ( Rates Are Per Pole / Km ) & Headload Cartage Of Small Material. Rates Are Per Km / Quintal Including Loadingand Unloading & Headload Cartage / Manual Shifting / Lifting With Crane / Hydraof The Following Transformers Along With Loading / Unloading At Both Points ( The Rates Are Per Transformer / Km ) . 38 Sp-21 / 23 39 Sp-33 40 Sp-55 41 Sp-72 42 Pccpoles 43 Small Line Material 44 25 Kva Transformer 11 / 0.4Kv 45 63 Kva Transformer 11 / 0.4Kv 46 100 Kva Transformer 11 / 0.4Kv 47 Excavation Of Earth For Pole Pit Of Size 0.9X0.6X1 / 6 Of Full Length Of Pole For Erection Of Pole In All Type Of Soil Including Proper Dressing Of Sides And Ramming Of Bottom Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Complete Work 48 Erection Of Following Singlesupport Polein Proper Level And Alignmentas Per Resspo Construction Manual. 49 Sp-21 50 Pcc Pole 51 Sp-23 52 Sp-33 53 Sp-55 54 Sp-72 55 Erection Of Following Double Support Pole In Proper Level And Alignment Alongwith Fixing Of All Accessories, Like Top Channel, X-Bracing & Clampsas Per Resspo Construction Manual. 56 Pccpole 57 Sp-23 58 Sp-33 59 Sp-55 60 Sp-72 61 Erection Of Following Four Pole Support In Proper Level And Alignment Alongwith Fixing Of All Accessories, Like Top Channel, X-Bracing & Clampsas Per Resspo Construction Manual. 62 Sp-23 63 Sp-33 ( 11Kv / 33Kv ) 64 Sp-55 ( 11Kv / 33Kv ) 65 Sp-72 ( 11Kv / 33Kv ) 66 Grouting Of Pole In Size 0.45X0.45X1 / 9 Of The Support In Cc Ratio 1:4:8 ( 1 Cement :4 Graded Stone 20Mm Nominal Size : 8 Coarse Sand ) Block Including Cost Of Cement, Sand Andstone Ballast Back Filling Of Soil And Boulders In Pit And Ramming And Proper Alignment, Leveling As Per Resspo Construction Manual. 67 Muffing Of Poles Of Size 45Cm Above Ground Level With Cc Ratio 1:4:8 ( 1 Cement :4 Graded Stone 10Mm Nominal Size : 8 Coarse Sand ) Block Including Cost Of Cement, Sand Andstone Ballast Back Filling Of Soil And Boulders In Pit And Ramming And Proper Alignment, Leveling As Per Resspo Construction Manual. 68 Fabrication Of M.S. Channel Angle Iron After Cutting In Requiredsizes With Drilling Of Holes Upto Good Finish For Top Channel, Bracing And Special Type Bracket Etc. As Per Resspo Sehedule And Local Approved Drawing. 69 Fixing Of Special Type Bracket 70 Fixing Of D-Type Bracket In Lt Line 71 Fixing Of Triangular Type Bracket In 11 Kvline 72 Fixing Of Triangular Type Bracket In 33 Kvline 73 Excavation Of Earth For Stay Pit Of Size 0.6X0.6X1.2Mtrin All Type Of Soil Including Proper Dressing Of Sides And Ramming Of Bottom Including Getting Out The Excavated Soil And Disposal Of Surplus Excavated Soil As Directed Complete Work 74 Fixing , Tightening And Nozzaling Of Stay With Pole And Stay Rod On Required Tension As Per Drawing / Resspo Manual. 75 Lt Stay 76 11 Kv Line 77 33 Kv Line 78 Grouting Of Stay In Size 0.6X0.6X0.3 In Cc Ratio 1:4:8 ( 1 Cement :4 Graded Stone 20Mm Nominal Size: 8 Coarse Sand ) Block Including Cost Of Cement, Sand Andstone Ballast Back Filling Of Soil And Boulders In Pit And Ramming And Proper Alignment, Leveling As Per Resspo Manual. 79 Earthing Of Lt / 11 Kv / 33 Kv Support With M.S. Earth Rod Of 2.5 Meter Long By Hammering Of M.S. Rod To Proper Depth And Connectingg.I. Wire As Per Construction Manual & Head Of The Earth Rod Should Be 30Cm Below The Ground Level. 80 Laying, Spreading, Stringing And Sagging Of 11 Kv / 33 Kv Line In 3 Phase ( 3 Phase 4 Wire ) Of The Following Wire As Phase Wire With G.I. Earth Wire Complete Including Fixing Of All Accessories In 3 Nos. Conductor In Parallel With Binding And Jumpering As Per Profile And Profile And Sagging Chart. 81 Weasel 82 Acsr Rabbit 83 Raccoon ( L.L. 11 Kv / 33 Kv ) 84 Dog ( L.L. 11 Kv / 33 Kv ) 85 Panther ( 33 Kv Line ) 86 Laying, Spreading, Stringing And Sagging Of L.T. Lines Of The Following Wire As Phase Wire With G.I. Earth Wire Complete With Binding And Jumpering As Per Resspo Specn. 87 Acsr Weasel Conductor 88 3 Phase 5 Wire Length 89 3 Phase 4 Wire Length 90 2 Phase 3 Wire Length 91 1 Phase 2 Wire Length 92 Acsr Rabbit Conductor 93 3 Phase 5 Wire Length 94 3 Phase 4 Wire Length 95 2 Phase 3 Wire Length 96 1 Phase 2 Wire Length 97 Acsr Raccoon Conductor 98 3 Phase 5 Wire Length 99 3 Phase 4 Wire Length 100 2 Phase 3 Wire Length 101 1 Phase 2 Wire Length 102 Acsr Dog Conductor 103 3 Phase 5 Wire Length 104 3 Phase 4 Wire Length 105 2 Phase 3 Wire Length 106 1 Phase 2 Wire Length 107 Guarding Of Line Over ( Telephone / Road / L.T. Line Crossing As Per Drawing With 6 / 8 Swg G.I. Wire Including Fixing Of Guarding Channel / Angle As Per Resspo Manual. L.T. / 11Kv / 33Kv 108 L.T. / 11Kv Line. 109 33Kv Line. 110 Laying And Erection Of L.T. Pvc Cable Including Crimping Of Lugs Of Size 1X70, 120, 150 Sq.Mm. 111 Mounting & Fixing Of Tpmoon Double Pole Structures Including Making Of Connections Complete Work 112 Mounting & Fixing Of Fuse Sets On Double Pole Structures Including Making Of Connections Complete Work 113 Mounting And Fixing Of Lightning Arrestor Set ( 3 Nos. ) On Double Pole Structure Including Making Allconnections By G.I. Strip Size 35X6 Mm To Earth Point Complete Work ( Excluding Cost Of G.I.Strip ) 114 Painting Of Poles With Angle And Channel And All Steel Part By One Coat Of Rod Oxide Primer And Two Coats Of Aluminium Paint And Two Strip Of Fluorescent Altemate Red And White Paint 30 Cm Wide Upto 1.5 Mtrs. From Ground Level. 115 St Pole Sp-55 116 St Pole Sp-33 117 St Pole Sp-23 / 21 118 St Pole Sp-10 119 St Pole Sp-72 120 Connection Of Existing Service Connections By Loop Jumpering On Main Line Through Catenary Wire 12 Swg And Eye Rag Bolt At Consumer Premisse Including Supply Of Catenary Wire And Eye Rag Bolt In Size 150X12 Mm As Per Resspo Schedule. 121 Jointing And Fixing Of Cable Jointing Kits Indoor / Outdoor Cable Boxes. 122 11 Kv Xlpeheat Shrinkable 123 33 Kv Xlpeheat Shrinkable 124 Straight Through 11 Kv Xlpe 125 Straight Through 33 Kv Xlpe 126 Dismantling Of Tpmo / Fuse Set On Double Pole Structure. 127 Dismantling Of Existing Transformeretc. Including Disc Fitting, Insulator, Clamps, Nut & Bolts And Consumer Connections Including Cartage Back From Site To Je Store 128 100 Kva 129 63 Kva 130 25 Kva 131 Installation / Mounting Of New Tranformer On Doublepole Structure And Fixing Of Channel / Angle Etc. And Making All Connections Of Ht And Lt Side And Its Complete Commissioning. 132 100 Kva 133 63 Kva 134 25 Kva 135 Route Cleareance By Cutting Of Tree Branches / Proning, Loping And Chopping Of Trees For L.T., 11 & 33 Kv Line. 136 T-Off Connection Complete 11 Kv 137 T-Off Connection Complete 33 Kv 138 Providing And Fixing Of Danger Board And Number Plate Complete By Providing Clamps Of M.S. Flat 50X6 Mm And Nuts & Bolts, Danger Boards Of M.S. Sheet 2 Mm Thick 11X7 Size ( Including Cost Of All Material ) 139 Laying Oflt Servicecable From Pole To Consumer End Meter Alongwith Supporting Gi Wire 140 Digging Of Trench Of Size 0.60X0.15 X 0.9 Mtr. And Laying Of Undergroundlt Cable With Makingof Brick Housing And Filling Of Sand Including Filling Of Earth With Ramming. & Repairing Of Road Includingcost Of Cement Sand And Stone Blast 141 Digging Of Trench Of Size 0.60X0.15 X 1.5 Mtr. And Laying Of Underground11 Kv Xlpe Cable With Makingof Brick Housing And Filling Of Sand Including Filling Of Earth With Ramming. & Repairing Of Road Includingcost Of Cement Sand And Stone Blast 142 Digging Of Trench Of Size 0.60X0.15 X 1.5 Mtr. And Laying Of Underground33 Kv Xlpe Cable With Makingof Brick Housing And Filling Of Sand Including Filling Of Earth With Ramming. & Repairing Of Road Includingcost Of Cement Sand And Stone Blast 143 Re- Alignement Of Tpmo On Existing Double Polewith Digging Of Pit And Fixing Of Tpmo On The Double Pole With Smooth Operating Including Making Of Gung And Jumper With Binding Kit. 144 Making Of Section Pole For Existing Lt / Ht / 33Kv Line Complete In All Respect. 145 Installation Of 33 / 11 Kv Metering Cubical In The Metering Room With Groutingand Making All Connection 146 Fixing Of Gi Pipe Complete. 147 Fixing Of Rcc Cable Route Marker Including Cost Material 148 Laying, Sagging & Binding Of Ab Cable Lt Line Complete. 149 Lt Ab Cable 3X120+1X95 Sq Mm 150 Lt Ab Cable 3X95+1X70 Sq Mm 151 Lt Ab Cable 3X25 / 15+1X25 Sq Mm 152 Laying, Sagging & Binding Of Ab Cable Ht Line Complete. 153 Loading, Unloading & Carriage Of Lt Prmc From Store To Pit Site & Installation On The Double Pole With The Help Of Nut Bolt & Clamp And Making To Pass Lt Cable From T / F To Prmc. 154 Construction Of Metering Room For Metering Cubical At S / S Endincluding Cost Ofbuilding / Materialand It Also Include The Cost Of Gate Etc.Of 10 Feet Height 155 Layingof Lt Cableinhalf Circlehume Pipe Of Dia 150 Mm Including Cost Of Hume Pipe In Depth 0.9 Meter 156 Layingof 11 Kvcableinhalf Circlehume Pipe Of Dia 150 Mm Including Cost Of Hume Pipe In Depth 1.5 Meter 157 Layingof 33 Kv Cableinhalf Circlehume Pipe Of Dia 150 Mm Including Cost Of Hume Pipe In Depth 1.5 Meter 158 Mannual Shifting / Pulling From Existing Site To Plinth / Nearby Place Distance Upto 200 Mtrs. 159 Control Realy Panel For Single T / F / Single Feeder 160 11 Kv Vcb Fdr 350 Mva / 500 Mva, 400 / 200 / 5A / 110 V Ac 161 33 Kv Vaccumecircuit Breaker 162 33 Kv Outdoor Ct / Pt 163 33 Kv Isolator Line / Bus 164 33 Kv Ct-Pt Combined Unit Off Sizes 165 11 Kv Ct-Pt Combined Unit Off Sizes 166 Fabrication & Erection Bus Isolator / Line Isolator / La / Ct / Pt / Fuse Set 167 Fabrication Charges 168 Excavation Of Earth For Erection Of Structure ( 2X1.1X0.3X0.3 ) 169 Grouting Of Structure In Cc 1:3:6 In Size ( 2X1.1X0.3X0.3 ) Mtr. 170 Erection Charges Of Structure 171 Installation Of 33 Kv Ct With All Connections 172 Erection Of 11 Kv Vcb ( O / G Or B / C Ori / C ) Panel In All Respect, Making Connection, Testing Etcin All Respect Aterection Site 173 Erection Of 33 Kv Control Panel ( Feeder / Transformer ) In All Respect, Making Connection Complete Including Testing And Commissioning. 174 Erection Of 33 Kv Vaccum Circuit Breaker In All Respect, Making Connection Including Testing And Commissioning. 175 Painting Of Isolator / La / Ct / Structure Complete 176 Fixing Of Stay Clamps For Pcc Pole. 177 Fixing Of Special Type Holding Clamps For J / Eye Hook. 178 Laying Of 11Kv Cable In 1.5 Mtr Depth With Suitable Trencheless Technology Including Laying In Trench With Providing & Fixing Of Hdpe Pipe Pe 80 Pn 6 & Having Dia 160 Mm Confermingto Is 4984 / 1995 & Having Thickness 9.1 To 10.3Mm. 179 Laying Of 33 Kv Cable In 1.5 Mtr Depth With Suitable Trencheless Technology Including Laying In Trench With Providing & Fixing Of Hdpe Pipe Pe 80Pn6 & Having Dia 160Confermingto Is 4984 / 1995 & Having Thickness 9.1 To 10.3Mm. 180 Replacement Of 3 Nos. 11 Kv Ct Inside The 11 Kv Metering Cubicle Including Cleaning Of Metering Cubicle 181 Replacement Of 3 Nos. 33 Kv Ct Inside The 33Kv Metering Cubicle Including Cleaning Of Metering Cubicle

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 21-Oct-2022 EXTENTION OF DATE Date 09-11-2022
2 09-Nov-2022 DATE EXTENTION Date 22-11-2022

Key Value

Document Fees
INR 590 /-
EMD
INR 26000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: Workfor Releasing of HT and LT New Service Connections in 33/11 KV S/S Manpur and Pakkakot under EDSD, Kashipur (Town) under the Head NSC (Capital Plan).
Sl. No. Item Description
1Decentralized Material
2Supply of Aluminum Crimping Lugs of size 25 Sq.mm.
3Supply of Aluminum Crimping Lugs of size 70 Sq.mm.
4Supply of Aluminum Crimping Lugs of size 95 Sq.mm.
5Supply of Aluminum Crimping Lugs of size 120 Sq.mm.
6Supply of LT Clamp with N&B PCC Pole 8.5Mtr. Long (MS flat 50X6mm & 18m dia hole for 16x65mm nut & bolt as per RESPO Specification)
7Supply of Stay Clamp with N&B PCC Pole 8.5Mtr.Long (MS flat 50X6mm & 18m dia hole for 16x65mm nut & bolt as per RESPO Specification)
8Supply of Stay Clamp with N&B ST Pole SP-33 (MS flat 65X8mm)
9Supply of Stay Clamp with N&B ST Pole SP-55 (MS flat 65X8mm)
10Supply of LT Shackle Insulator with one nonut bolt 150x16mm made of best quality pore line and without defeets ISI standard as per UPCL specification.
11Supply of Stay Insulator 90X65 mm.
12Supply of Holding Clamp with N&B PCC Pole 8.5Mtr Long (MS flat 50X6mm & 18m dia hole for 16x65mm nut & bolt as per RESPO Specification)
13Supply of all type PP & Clamp with nut & bolt ( as per RESPO Specification)
14Supply of F-Clamp for 11KV PCC pole Line made of flat 65X6mm with N&B.
15Supply of Dead End clamps with I-Hook. (As per Specification & Drawing of UPCL)
16Supply of Suspension clamps with I-Hook. (As per Specification & Drawing of UPCL)
17Holding Clamp for Dead End Clamp suitable for AB Cable (As per Specification & Drawing of UPCL)
18Holding Clamp for Suspension Clamp suitable for AB Cable (As per Specification & Drawing of UPCL)
19Supply of LT Insulated Pearcing Connector 120/95 to 120/95 mm. (For Line to Line) (As per Specification & Drawing of UPCL)
20Supply of LT Insulated Pearcing Connector 120/95 to 25/15 mm. (For Line to Line) (As per Specification & Drawing of UPCL)
21Supply of LT Insulated Pearcing Connector 25/15 to 25/15 mm. (For Line to Line) (As per Specification & Drawing of UPCL)
22Supply of L.T. Bare Neutral Connectors PG clamp 95sq mm to 25 sq mm. (For Line to Line) (As per Specification & Drawing of UPCL)
23Labour Charges
24Cartage of ST pole and PCC Poles from store centre to construction site with loading, unloading at both points. (loading, unloading pluse carriage per pole) and proper stacking, Cartage of other material (other than poles) by vehicle fro Store Center to nearest construction site Store including loading and unloading at both ends & Cartage of the following capacity transformers from store center to construction site with loading and unloading at both points. (Loading, unloading plus carriage of T/F)( 0-20 KM)
25SP-21/23
26SP-33
27SP-55
28SP-72
29PCCPoles
30Other material in weight
3125 KVA
3263 KVA
33100 KVA
3411KV VCB(I/c,O/g) bus cupler,Pannels
3533KV VCB,feeder Pannels(O/d),T/f Control pannel
3633/11 CT/PT /Isolator
37Headload cartage of following Poles from road to site (Rates are per pole / KM ) & Headload cartage of Small material. Rates are per Km/Quintal including loadingand Unloading & Headload cartage/ manual shifting / lifting with crane/hydraof the following transformers along with loading/Unloading at both points (the rates are per transformer/Km).
38SP-21/23
39SP-33
40SP-55
41SP-72
42PCCPoles
43Small line material
4425 KVA Transformer 11/0.4KV
4563 KVA Transformer 11/0.4KV
46100 KVA Transformer 11/0.4KV
47Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole in all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work
48Erection of following Singlesupport polein proper level and alignmentas per RESSPO construction Manual.
49SP-21
50PCC Pole
51SP-23
52SP-33
53SP-55
54SP-72
55Erection of following Double support pole in proper level and alignment alongwith fixing of all accessories, like top channel,X-bracing & clampsas per RESSPO construction Manual.
56PCCPole
57SP-23
58SP-33
59SP-55
60SP-72
61Erection of following Four pole support in proper level and alignment alongwith fixing of all accessories, like top channel,X-bracing & clampsas per RESSPO construction Manual.
62SP-23
63SP-33 (11KV/33KV)
64SP-55 (11KV/33KV)
65SP-72 (11KV/33KV)
66Grouting of pole in size 0.45x0.45x1/9 of the support in CC ratio 1:4:8 (1 cement :4 graded stone 20mm nominal size : 8 coarse sand ) block including cost of Cement,sand andstone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO construction Manual.
67Muffing of poles of size 45cm above ground level with CC ratio 1:4:8 (1 cement :4 graded stone 10mm nominal size : 8 coarse sand ) block including cost of Cement,sand andstone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO construction Manual.
68Fabrication of M.S. Channel Angle iron after cutting in requiredsizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESSPO sehedule and local approved drawing.
69Fixing of special type bracket
70Fixing of D-type bracket in LT line
71Fixing of triangular type bracket in 11 KVline
72Fixing of triangular type bracket in 33 KVline
73Excavation of earth for Stay pit of size 0.6x0.6x1.2mtrin all type of soil including proper dressing of sides and ramming of bottom including getting out the excavated soil and disposal of surplus excavated soil as directed complete work
74Fixing , tightening and nozzaling of Stay with pole and stay rod on required tension as per drawing / RESSPO manual.
75LT stay
7611 KV line
7733 KV line
78Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8 (1 cement :4 graded stone 20mm nominal size: 8 coarse sand ) block including cost of Cement,sand andstone ballast back filling of soil and boulders in pit and ramming and proper alignment, leveling as per RESSPO Manual.
79Earthing of LT/11 KV/ 33 KV support with M.S. Earth rod of 2.5 meter long by hammering of M.S. Rod to proper depth and connectingG.I. wire as per construction manual & Head of the earth rod should be 30cm below the ground level.
80Laying, Spreading, Stringing and sagging of 11 KV / 33 KV line in 3 phase (3 Phase 4 wire) of the following wire as phase wire with G.I. earth wire complete including fixing of all accessories in 3 Nos. conductor in parallel with binding and jumpering as per profile and profile and sagging chart.
81Weasel
82ACSR Rabbit
83Raccoon (L.L. 11 KV / 33 KV)
84Dog (L.L. 11 KV / 33 KV)
85Panther (33 KV line)
86Laying, Spreading, Stringing and sagging of L.T. Lines of the following wire as phase wire with G.I. earth wire complete with binding and jumpering as per RESSPO Specn.
87ACSR Weasel Conductor
883 phase 5 wire length
893 phase 4 wire length
902 phase 3 wire length
911 phase 2 wire length
92ACSR Rabbit Conductor
933 phase 5 wire length
943 phase 4 wire length
952 phase 3 wire length
961 phase 2 wire length
97ACSR Raccoon Conductor
983 phase 5 wire length
993 phase 4 wire length
1002 phase 3 wire length
1011 phase 2 wire length
102ACSR Dog Conductor
1033 phase 5 wire length
1043 phase 4 wire length
1052 phase 3 wire length
1061 phase 2 wire length
107Guarding of Line over (Telephone / Road / L.T. line crossing as per drawing with 6/8 SWG G.I. wire including fixing of guarding channel/ angle as per RESSPO manual. L.T./11KV /33KV
108L.T./11KV Line.
10933KV Line.
110Laying and erection of L.T. PVC Cable including crimping of lugs of size 1x70,120, 150 Sq.mm.
111Mounting & Fixing of TPMOon double pole structures including making of connections complete work
112Mounting & Fixing of Fuse sets on double pole structures including making of connections complete work
113Mounting and Fixing of Lightning arrestor set (3 Nos.) on double pole structure including making allconnections by G.I. strip size 35x6 mm to earth point complete work (excluding cost of G.I.Strip)
114Painting of poles with angle and channel and all steel part by one coat of Rod Oxide Primer and two coats of aluminium Paint and two strip of fluorescent altemate Red and White paint 30 Cm wide upto 1.5 Mtrs. From ground level.
115ST Pole SP-55
116ST Pole SP-33
117ST Pole SP-23/21
118ST Pole SP-10
119ST Pole SP-72
120connection of existing service connections by Loop jumpering on main line through catenary wire 12 SWG and eye rag bolt at consumer premisse including supply of catenary wire and eye rag bolt in size 150x12 mm as per RESSPO schedule.
121Jointing and Fixing of cable jointing Kits indoor /outdoor cable boxes.
12211 KV XLPEheat shrinkable
12333 KV XLPEheat shrinkable
124Straight through 11 KV XLPE
125Straight through 33 KV XLPE
126Dismantling of TPMO /fuse set on double pole structure.
127Dismantling of existing Transformeretc. including disc fitting, Insulator, clamps, Nut & Bolts and consumer connections including cartage back from site to JE store
128100 KVA
12963 KVA
13025 KVA
131Installation / mounting of new Tranformer on doublepole structure and fixing of channel / angle etc. and making all connections of Ht and LT side and its complete commissioning.
132100 KVA
13363 KVA
13425 KVA
135Route cleareance by cutting of tree branches / proning, loping and chopping of trees for L.T., 11 & 33 KV line.
136T-off Connection Complete 11 KV
137T-off Connection Complete 33 KV
138Providing and fixing of Danger Board and number plate complete by providing clamps of M.S. Flat 50x6 mm and Nuts & Bolts, danger Boards of M.S. Sheet 2 mm Thick 11""x7"" size (Including cost of all material)
139Laying ofLT serviceCable From Pole to consumer end meter alongwith supporting GI wire
140Digging of trench of size 0.60x0.15 x 0.9 mtr. and laying of undergroundLT cable with makingof brick housing and filling of sand including filling of earth with ramming. & repairing of road includingcost of cement sand and stone blast
141Digging of trench of size 0.60x0.15 x 1.5 mtr. and laying of underground11 KV XLPE cable with makingof brick housing and filling of sand including filling of earth with ramming. & repairing of road includingcost of cement sand and stone blast
142Digging of trench of size 0.60x0.15 x 1.5 mtr. and laying of underground33 KV XLPE cable with makingof brick housing and filling of sand including filling of earth with ramming. & repairing of road includingcost of cement sand and stone blast
143Re- alignement of TPMO on existing Double polewith digging of pit and fixing of TPMO on the double pole with smooth operating including making of gung and jumper with binding kit.
144Making of section pole for existing LT/HT/33KV line complete in all respect.
145Installation of 33/11 KV Metering cubical in the Metering room with groutingand making all connection
146Fixing of GI pipe complete.
147Fixing of RCC cable route marker Including cost material
148Laying, sagging & binding of AB cable LT line complete.
149LT AB Cable 3x120+1x95 sq mm
150LT AB Cable 3x95+1x70 sq mm
151LT AB Cable 3x25/15+1x25 sq mm
152Laying, sagging & binding of AB cable HT line complete.
153Loading, unloading & carriage of LT PRMC from Store to pit site & Installation on the double pole with the help of Nut Bolt & Clamp and making to pass LT cable from T/F to PRMC.
154Construction of Metering room for Metering Cubical at S/s endIncluding cost ofbuilding /materialand it also include the cost of gate etc.Of 10 feet height
155Layingof LT CableinHalf circleHume pipe of Dia 150 mm including cost of hume pipe in depth 0.9 meter
156Layingof 11 KVCableinHalf circleHume pipe of Dia 150 mm including cost of hume pipe in depth 1.5 meter
157Layingof 33 KV CableinHalf circleHume pipe of Dia 150 mm including cost of hume pipe in depth 1.5 meter
158Mannual shifting /Pulling from existing site to plinth/ nearby place distance upto 200 mtrs.
159Control Realy Panel for Single T/F/ Single Feeder
16011 KV VCB FDR 350 MVA / 500 MVA, 400/200/5A/110 V AC
16133 KV VACCUMECIRCUIT Breaker
16233 KV outdoor CT/PT
16333 KV Isolator Line/Bus
16433 KV CT-PT combined Unit off sizes
16511 KV CT-PT combined Unit off sizes
166Fabrication & erection Bus Isolator / Line Isolator / LA / CT / PT/ Fuse set
167Fabrication charges
168Excavation of earth for erection of structure (2x1.1x0.3x0.3)
169Grouting of structure in CC 1:3:6 in size (2x1.1x0.3x0.3) mtr.
170Erection charges of structure
171Installation of 33 KV CT with all connections
172Erection of 11 KV VCB (O/G or B/C orI/C ) Panel in all respect, making connection, testing etcin all respect aterection site
173Erection of 33 KV control panel( feeder /transformer )in all respect, making connection complete including testing and commissioning.
174Erection of 33 KV VACCUM CIRCUIT Breaker in all respect, making connection including testing and commissioning.
175Painting of Isolator / LA/CT/Structure complete
176Fixing of Stay Clamps for PCC Pole.
177Fixing of Special type Holding clamps for J/Eye Hook.
178Laying of 11KV Cable in 1.5 mtr depth with suitable trencheless technology including laying in trench with providing & fixing of HDPE pipe PE 80 PN 6 & having dia 160 mm confermingto IS 4984/1995 & having thickness 9.1 to 10.3mm.
179Laying of 33 KV Cable in 1.5 mtr depth with suitable trencheless technology including laying in trench with providing & fixing of HDPE pipe PE 80PN6 & having dia 160confermingto IS 4984/1995 & having thickness 9.1 to 10.3mm.
180Replacement of 3 nos. 11 KV CT inside the 11 KV metering cubicle including cleaning of metering cubicle
181Replacement of 3 nos. 33 KV CT inside the 33KV metering cubicle including cleaning of metering cubicle
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail