Tender For Facility Creation For Plant Growth Chamber ( Electrical Work ), palampur-Himachal Pradesh

Council Of Scientific And Industrial Research-CSIR has published Tender For Facility Creation For Plant Growth Chamber ( Electrical Work ). Submission Date for this Tender is 12-10-2022. Planting and Seeding Machinery Tenders in palampur Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34250954
Tender For Facility Creation For Plant Growth Chamber ( Electrical Work )
Open Tender
Indian
Himachal Pradesh
palampur
12-10-2022

Tender Details

tender for Facility Creation For Plant Growth Chamber ( Electrical Work )

Key Value

Document Fees
INR 500 /-
EMD
INR 13500.0 /-
Tender Value
INR 6.71 Lakhs /-

BOQ Items

Name of Work:Facility Creation for Plant Growth Chambers - (Electrical Works)
Sl. No. Item Description
1Wiring for light point/fan point/exhaust fan point/call bell point with 1.5 sq.mm. FRLS insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sqmm FRLS PVC insulated copper conductor single core cable etc as required.(Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West ). ( FRLS Copper Wire Make: KEI/ANCHOR/ FINOLEX) i) Group C
2Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. ( FRLS Copper Wire Make: KEI/ANCHOR/ FINOLEX)
3Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.( FRLS Copper Wire Make: KEI/ANCHOR/ FINOLEX)
4Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required. i) 2x1.5 sqmm + 1x1.5 sqmm earth wire( FRLS Copper Wire Make: KEI/ANCHOR/ FINOLEX)
5Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required.i) 2x2.5 sqmm +1x2.5 sqmm earth wire ( FRLS Copper Wire Make: KEI/ANCHOR/ FINOLEX)
6Wiring for circuit/ submain wiring alongwith earthwire with the following size of FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit as required.i) 2x6 sqmm +1x6 sqmm earth wire( FRLS Copper Wire Make: KEI/ANCHOR/ FINOLEX)
7Supplying & drawing followingpair 0.5 mm dia FRLS PVC insulated anneaaled copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required. i)2 Pair
8Supplying & fixing of following sizes of ISI medium class PVC conduit alongwith accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.i)25 mm
9Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.i) 1 x 1.5 sq. mm( FRLS Copper Wire Make: KEI/ANCHOR/ FINOLEX)
10Supplying & fixing 2 Module Stepped type Electronic Fan Regulator on existing Modular Plate Switch box including connection but excluding modular plate extra as required. (Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
11Supplying & fixing modular blanking plate on the existing modular plate switch box excluding modular plate as required.
12Supplying & fixing following size/ modules, GI/ PVC box alongwith modular base & cover plate for modular switchs in recess etc as required.i)1 or 2 Module(75 mm x 75 mm)
13Supplying & fixing suitable size GI/ PVC box with modular plate in front on surface or in recess, including providing & fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.(Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
14Supplying and fixing 3 pin, 5 A ceiling rose on the existing juction box/wooden block including connection etc. as required.
15Installation, testing and commissioning of pre wired, fluorescent fitting/ compact fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, inc connection with 1.5 sqmm FRLS insulated, copper conductor, single core cable and earthing etc. as required.
16Installation, testing and commissioning of ceiling fan including wiring the down rod of standard length(upto 30 cm)with 1.5 sqmm FRLS insulated, copper conductor, single core cable inc providing and fixing Phenolic laminated sheet cover on the fan box etc. as required.
17Supplying and drawing of UTP 4 pair CAT 6 LAN cable in the existing surface/ recessed steel/ PVC conduit as required. (Make: D Link/ Digilink) i) 1 Run of Cable
18Supplying & fixing suitable size GI/PVC box with modular plate and cover in front on surface or in recess, including providing and fixing 2 No. 3 Pin 5/6 Amp. Modular socket outlet and 2 Nos. 5/6 Amp. Modular switch, connections etc. as required. ( FOR LIGHT PLUGS TO BE USED IN NON RESIDENTIAL BUILDING).(Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
19Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.(Modular Accessories Make: Anchor Roma/ Havells Crabtree/ Wipro North West )
20Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator(Make: Legrand/ Panasonic/ Hager/ Schneider). i) 6 way , Double door
21Supplying and fixing following way, surface/ recess mounting, vertical type,415 V, TPN MCB Distribution Board, sheet steel, dust protected, powder painted, inclusive of 200 A,tinned copper bus bar, neutral bus bar, earth bar, din bar for mounting MCBs & having provision for fixing of125 A, 16 KA,TPMCCB (But without MCBs and incomer) as required. (Make: Legrand/ Hager/ Schneider). i) 12 way (4 + 12), Double Door
22Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/ Hager/ Schneider ).i)Single pole
23Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/ Panasonic/ Hager/ Schneider ).i) Single pole & Neutral
24Supplying and fixing 5 amps to 32 amp. rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. (Make: Legrand/ Hager/ Schneider ).i) Triple pole
25Supplying and fixing 30A, 415V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30A ""C"" curve, TPMCB, in sheet steel enclosure on surface or in recess, with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required.
26Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required i) 100 mm width X 50 mm depth X 1.6 mm thicknes
27Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. i)100 mm width X 50 mm depth X 1.6 mm thicknes
28Earthing with copper earth plate 600 mm x 600 mm x 3 mm thick including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
29Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia GI pipe from earth electrode including connection with copper thimble excavation and refilling as required.
30Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required i)Above 35 sq. mm and upto 95 sq. mm
31Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required i)Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp
32Supplying, installation, testing & commissioning of smoke detector with builtin LED and mounting base complete with all connections etc. as required. ( Make: Apollo/ System sensor).
33Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. ( Make: HSD/ Agni Device/ System Sensor).
34Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. ( Make: HSD/ Agni Device/ System Sensor).
35Supplying, installation, testing & commissioning sector panel suitable for following zones, complete with visual indications for short circuit fault, open circuit fault, fire condition and all other standard facilities as per IS:2189 with mimic diagram for all area/zone covered, complete with all connections, interconnections as required. i) 4 Zone( Make: HSD/ Apollo/ System Sensor).
36Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required.
37Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
38Supplying & laying ofCat6Armoured cable on existing cable tray complete as required (Cat 6 Make:- Digilink or equivalent).
39Supllying, Installation, testing and commissioning of 24 Port 10/100/1000 Mbps WebManaged Switch (Make: CISCO/D LINK).
40SITC of 6U Wall mount rack with front glass/ acrylic lockable door. (Make: COMMRACK or eq.)
41Supplying & fixing Single Phase, 230 volts, 1400 RPM, Metal bodyexhaust fan / ventilating fan , size 225 mm sweep complete as required. (Make: Bajaj/ Havells/ Crompton)
42Providing and fixing following rating and breaking capacity andpole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. i)125 A, 16 KA,TPMCCB (Make: Legrand/Hager/ Schneider ).
43Supplying and testing of SURFACE mounted 36 Watt LED flat panel 2" x 2"made of CRCA sheet steel duly powder coated with high efficient LED & Glare free full opel Diffuser with system lumens - 120LM/watt, Height Of Fixture > 35 mm complete as required. (Make : Wipro/ Bajaj/ philips).
44SITCofRJ 45 computer Socket Cat 6 (I/O Box complete kit). (Make : D Link/ Digilink).
45Supplying & testing of Aluminium conductor, armoured, PVC insulated & PVC sheathed/ XLPE power cable of 1.1 KV grade of following sizes as required (Make: Polycab/ Havells/ KEI/ FINOLEX ) i)3.5 core 50 sqmm
46Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.i) Telephone socket outlet
47Supplying, testing & fixing ofrecess mounted, rounddownlight LED 18 Watt, 4000 K with pressure diecast aluminium housing for effective thermal management and HET diffuser for better performance suitable to fit cutout size 160 mmcomplete as required. (Make : Wipro/ Bajaj/ philips).