Tender For Procurement Of Various Single Phase Ac Dc Transducers Of Davr And Ht Lt Switchgear For T And C-Iv, Stps, Sarni.
Tender Overview
Project Description
Procurement Of Various Single Phase Ac Dc Transducers Of Davr And Ht Lt Switchgear For T And C-Iv, Stps, Sarni. Procurement Of Various Single Phase Ac Dc Transducers Of Davr And Ht Lt Switchgear For T And C-Iv, Stps, Sarni. , Single Phase Ac / Dc Transducers Of Davr And Ht / Lt Switchgear , Ac Programmable Current Transducer ( Single Phase ) Input - : Ct Ratio:-0-1…..6A. , Output : 4-16...20Madc At 500O Aux. Supply: 240V Ac / Dc ± 20% , 50 Hz, No. Of Outputs- 02 ( Minimum ) Accuracy Class : 0.2% , Ac Programmable Voltage Transducer ( Single Phase ) Input :0-110 Volt Ac Output : 4-20Ma Dc At 500O Aux. Supply: 240V Ac / Dc ± 20% , 50 Hz, No. Of Outputs- 02 ( Minimum ) Accuracy- ± 0.2% , Dc Voltage Transducer Input – 0-25 Volt Dc, Output – 4- 20 Ma No. Of Outputs – 02 , Aux. Supply -240V Ac / Dc ± 20%, 50 Hz Accuracy- ± 0.2% , Dc Voltage Transducer Input – 0-200 Volt Dc, Output – 4- 20 Ma No. Of Outputs – 02 , Aux. Supply -240V Ac / Dc ± 20% , 50 Hz Accuracy- ± 0.2% , Dc Voltage Transducer Input – 0-60 Milivolt Dc, Output – 4- 20 Ma No. Of Outputs – 02 , Aux. Supply -240V Ac / Dc ± 20%, 50 Hz Accuracy- ±0.2% , Dc Voltage Transducer Input – ( + ) 15-0- ( + ) 15, Output – 4- 16-20 Ma No. Of Outputs – 02 , Aux. Supply -240V Ac ± 20%, 50 Hz Accuracy- ± 0.2% , Dc Current Transducer Input – 0-75 Millivolt Dc, Output – 4- 20 Ma Dc At 500 Ohm Range-0-60 Adc, No. Of Outputs – 02 Aux. Supply -240V Dc / Ac ± 20%, 50 Hz Accuracy- ± 0.2%
Corrigendum
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 20-Oct-2022 | EXTENSION OF DUE DATE_1 | Date | 26-Oct-2022 |
BOQ
| Sl. No. | Item Description |
| 1 | Single Phase AC/DC Transducers of DAVR and HT/LT Switchgear |
| 2 | AC Programmable Current Transducer (Single Phase)Input - : CT Ratio:-0-1…..6A. , Output : 4-16...20mADC at 500?Aux. Supply: 240V AC/DC ± 20% , 50 Hz, No. of outputs- 02(Minimum)Accuracy Class : 0.2% |
| 3 | AC Programmable Voltage Transducer (Single Phase)Input :0-110 Volt AC Output : 4-20mA DC at 500?Aux. Supply: 240V AC/DC ± 20% , 50 Hz, No. of outputs- 02(minimum) Accuracy- ± 0.2% |
| 4 | DC Voltage Transducer Input – 0-25 Volt DC, Output – 4- 20 mANo. of Outputs – 02 , Aux. Supply -240V AC/DC ± 20%,50 HZAccuracy- ± 0.2% |
| 5 | DC Voltage Transducer Input – 0-200 Volt DC, Output – 4- 20 mANo. of Outputs – 02 , Aux. Supply -240V AC/DC ± 20% ,50 HZAccuracy- ± 0.2% |
| 6 | DC Voltage Transducer Input – 0-60 miliVolt DC, Output – 4- 20 mANo. of Outputs – 02 , Aux. Supply -240V AC/DC ± 20%, 50 HZAccuracy- ±0.2% |
| 7 | DC Voltage Transducer Input – (+)15-0-(+)15, Output – 4- 16-20 mANo. of Outputs – 02 , Aux. Supply -240V AC ± 20%, 50 HZAccuracy- ± 0.2% |
| 8 | DC Current Transducer Input – 0-75 millivolt DC, Output – 4- 20 mA DC at 500 Ohm Range-0-60 ADC, No. of Outputs – 02 Aux. Supply -240V DC/ AC ± 20%, 50 HZAccuracy- ± 0.2% |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedCorrigendum-1 Issued
Clarifications on tender conditions and amendments issued.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
Completed