Repair / Replacement Of Ceiling Fans For Otm Accn Of Certain Unit, Existing Lt Old Pcc / Rcc Pole To Steel Tubular Pole And Conversion Of Oh Line To Lt Ug Cable ... Under Ge Kamptee., kamptee-Maharashtra

Military Engineer Services-MES has published Repair / Replacement Of Ceiling Fans For Otm Accn Of Certain Unit, Existing Lt Old Pcc / Rcc Pole To Steel Tubular Pole And Conversion Of Oh Line To Lt Ug Cable ... Under Ge Kamptee.. Submission Date for this Tender is 29-10-2022. Electric Pole Tenders in kamptee Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

34221995
Corrigendum : Repair / Replacement Of Ceiling Fans For Otm Accn Of Certain Unit, Existing Lt Old Pcc / Rcc Pole To Steel Tubular Pole And Conversion Of Oh Line To Lt Ug Cable ... Under Ge Kamptee.
Open Tender
Indian
Maharashtra
kamptee
29-10-2022

Tender Details

Repair / Replacement Of Ceiling Fans For Otm Accn Of Certain Unit, Existing Lt Old Pcc / Rcc Pole To Steel Tubular Pole And Conversion Of Oh Line To Lt Ug Cable ... Under Ge Kamptee.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 14-Oct-2022 Corrigendum No 01 Financial Bid 17-10-2022
2 17-Oct-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 24-10-2022
3 21-Oct-2022 Corrigendum No 02 Date 29-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 68340.0 /-
Tender Value
INR 34.17 Lakhs /-

BOQ Items

Name of Work: REPAIR / REPLACEMENT OF CEILING FANS FOR OTM ACCN OF CERTAIN UNIT, EXISTING LT OLD PCC/RCC POLE TO STEEL TUBULAR POLE AND CONVERSION OF OH LINE TO LT UG CABLE AT CARIAPPA DWAR TO MT ROAD GRC, PROVN OF ELECTRIC SECURITY FENCING OF CERTAIN UNIT AND PROVN OF EXHAUST FANS IN KITCHEN FOR MD ACCN AT 299 AREA GRC UNDER GE KAMPTEE.
Sl. No. Item Description
1S&F electric fence controller, operating voltage 12V, 40 watt peak, solar DC, voltage input 12V, 26AH DC battery back up each fence controller having energizers to achieve following parameters complete all as specified and as directed.The fence controller should hae the following components and specifications:- (a) Nominal operating voltage shall be between 6000V to 10000V. (b) The pulse interval shall be of 1.2 second. (c) The pulse duration shall be of 1.2 second. Note:- (i) Warning and alerts shall be configured for system fault, serious breach and pulse count. (ii) The makes of the component / parts of solar fencing shall be as per manufacturer"s requirement and shall be of same company as far as possible batteries. (iii) M&L alarm device operating on 12V having audability of 125dB noise level, alarm must turn ON automatically at all the field controller locations when fence is damaged or voltage drop complete all as specified and directed. (iv) Solar module mounting arrangement pole with mounting structure with hardware 35x35x3mm thick angular iron "H" frame, 2" dia 8 feet long pole and angle adjustment mechanism 2 core cable for solar module to fence system complete all as specified and directed. (v) Supply of outdoor consolerack made of 3.15mm thick CRCA sheet suitable for extensive outdoor application compiling with IP55 standard for housing fence controller, battery, automatic voltage regulator, power supply board etc with suitable power supply distribution ON OFF control switches and internal wiring with suitable lock and key arrangement and including suitable mild steel angle iron frame including suitable work complete all as specified and directed. Make: Ashoka Solar or equivalent.
2S&F hook high density polyethylene UV stabilised insulator complete all as specified and as directed.Make: Ashoka Solar or equivalent.
3S&F Tension spring complete all as specified and as directed.Make: Ashoka Solar or equivalent.
4S&F corner insulator complete all as specified and as directed.Make: Ashoka Solar or equivalent.
5S&F high tensile wire zinc coating, corrosion resistant, having wire thickness 14SWG = 750 KGS, 16SWG = 50KGS complete all as specified and as directed.Make: Ashoka Solar or equivalent.
6S&F fastners nut bolts 5mm x 54mm nut & bolts pair complete all as specified and as directed.Make: Ashoka Solar or equivalent.
7S&F galvanised poles / angles height 1.5 mtr, wide 25mm, length 25mm with 11 holes (9 for insulator and 2 for attatching with wall by nails) complete all as specified and as directed.Make: Ashoka Solar or equivalent.
8S&F joint clamps complete all as specified and as directed.Make: Ashoka Solar or equivalent.
9S&F warning sign boards complete all as specified and as directed.Make: Ashoka Solar or equivalent.
10S&F nails with wall plug complete all as specified and as directed.Make: Ashoka Solar or equivalent.
11S&F wire tightener complete all as specified and as directed.Make: Ashoka Solar or equivalent.
12M&L for lightening diverter capable of diverting stray lightening from fence to earth complete all as specified and as directed.Make: Ashoka Solar or equivalent.
13S&F earth kit comprising of non rusting rod of 10mm dia inserted in moisture absorbent chemical mixture, earth kit weighing minimum 4 kg, 4 feet long, fastening assembly shall be of hot dip galvanised complete all as specified and as directed.Make: Ashoka Solar or equivalent.
14S&F HV double insulated cable made of two layer insulation of abrasion resistant HDPE and inner insulation of polypropylene, core shall be of 2.5mm galvanised steel, the diameter with inner insulation shall be 4.1mm and the diameter of the cable with both insulation shall be 7.6mm for inter connection between the fence controller and power fence complete all as specified and as directed consisting of following:- (i) S&F 20/25 mm dia rigid non metallic PVC conduitinclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc complete all as specified and directed. Make: Ashoka Solar or equivalent.
15S&F ceiling fan of 1200mm sweep with three blades, 230V, 50 Hz complete with down rod and all accessories with squirrel cage induction motor, copper wounded type with minimum two years warranty complete all as specified and as directed.
16Dismantling and setting aside ACSR conductor any size including binding with copper / aluminium binding wire to over head conductor complete all as specified and as directed.
17Dismantling and setting aside concrete poles/ struts, any size complete all as specified and directed.
18Dismantling and setting aside existing cross arms of MS channel or angle sections etc from pole 2 pole structure / 4 pole structure for reuse or existing 2 pole structure / 4 pole structure of any size complete all as specified and directed.
19Dismantling and setting aside existing pin / shackle / Loop / disc HT insulator etc of any size from 2 pole structure / 4 pole structure complete all as specified and directed.
20Excavation in trenches in any type of soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of Cables,poles, stay and getting out of excavated material complete all as specified and directed.
21S&F double wall corrugated high density polymer ethyl (HDPE) pipe for laying of electric cable of size 63mm outer diameter and 51mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
22S&F double wall corrugated high density polymer ethyl (HDPE) pipe for laying of electric cable of size 120mm outer diameter and 103.5mm inner diameter with IS 14930 (part 2):2001 laid in trenches, wall, floor, pole including bends, sockets and other connected accessories complete all as specified and directed.
23Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed.
24Removal of surplus soil to a distance not exc. 50m and deposited where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
25Supply and install steel tubular swaged pole type 410 SP-22 (8.5Mtrs long)complete with CI base plate and finial including foundation and coping Conforming to IS 2713 (Part-I to III) 1980 all as specified including two coats of black bitumen paint throughout internally and externally upto planting depth and applying two coats of aluminum paint over one coat of red oxide primer (externally) and writting of MES Numbering of poles as directed including excavation / earth work, PCC (1:4:8) type D-2 using 40 mm aggregate for pole foundations of size 600 x 600 x 1500 mm height upto ground level and using including necessary formwork complete with taking down old unserviceable pole all as specified and as directed.
26Supply and Laying in trenches or fixing in walls / poles or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 120 sq mm, 3.5 core including testing after laid and jointed with lugs, nuts, bolts, washers complete all as specified and directed.
27All as per item No 26 above but of size 25 sq mm4 core complete all as specified and directed.
28All as per item No 26 above but of size 10 sq mm 4 core complete all as specified and directed.
29Fabrication, Supplying Installing, testing & Commissioning outdoor type feeder pillar box with rain cowl weather / verminproof, outdoor type, factory made LT panel, from any CPRI approved manufacturer having dimensions of suitable size with sufficient space between MCCB cable connections place and body of panel for easily working to workers including necessary incoming & outgoing cable connections, cable glands, thimbles of required sizes, made out of MS CRCA sheet 3.00 mm thick for outer shell and 2mm thick for inner shell duly powder coated paint with inner shutter & outer double door, the cubical shall have a bottom channel of size 75x40x5mm duly coated with zinc metal coating with stainless steel locking handle arrangement both side openable fixed on 75 x 75 x 5 mm MS angle frame fixed 300mm above groud level & 450mm below the ground grouted in & including PCC 1:3:6 type C1 (using 20mm graded stone aggregate) complete all as specified, directed & comprising of following including refixing existing cables to new panels by proper lugging & cable gland as required. (a) Busbar chamebr for 3 phase & nuetral of capacity 300 Amps (30mm x 10mm) alumunium bus bar duly insulated. (b) Multifunctioning meter to measure Voltage, ampere, KWH,PF -1 Nos (c) one set of pilot lamp. (d) Incoming MCCB 100 amps 4 Pole 415 volts 25 KA thermal magnetic setting type- 1 Nos. (e) Outgoing Type DRX MCCB 63 amps 3 pole 415 volts 10 KA thermal magnetic setting - 3 Nos
30S&F thermoplastic cable junction boxes IP 55/IP65 with metric knockout for cable entry of size 200 x 160 x 98mm fixing on pole with 30 x 5mm MS clamps, nut bolts, washers, terminal block and glands suitable for 16 Sq mm core cable including 6-32 amps MCB SP complete all as specified and directed.
31M&L for earthing complete with galvanized steel earth plate electrode 600 x 600 x 6mm thick buried directly in ground vertically to a depth not less than 2.25m below ground level with top edge of earth plate not less than 1.5m below ground level connected to galvanized iron earth strip 32 x 6mm by means of bolts, nuts, check nuts, washers of galvanized ironand connected to main switch/control board upto 7.5m away from the earth electrode including excavation earth work, PCC chamber, RCC cover slab char coal, watering pipe, wire mesh lugs, earth lead protection pipe 15mm bore, light grade 7.5m long as applicable and as per plate No. 3 of SSR 2009 and all as specified. (a) Excavation and earth work in any type of soil. (b) Drilling of holes in electrode (c) PCC pit in cement concrete (1:2:4) type B-1 (d) 40 mm thick Pre-cast RCC cover with suitable handle. (e) Funnel with watering pipe of GI 20 mm nominal bore ,mediumgrade & copper lug etc. (f) 50mm nominal bore medium grade GI protection pipe 7.50 m long for protection of earthing lead. (g) Requisite quantity of charcoal and common salt. (h) Connection to earthing test point and testing on completion.
32M&L for point wiring 1100 volt grade single core FRLSH PVC insulated and unsheathed cable with multistranded copper conductor 1.50 sqmm drawn in and including electrical grade PVC conduit not less than 20mm dia with IS 9537 (Part-III) 1983 marked medium grade concealed on wall/ceiling including FRLSH PVC insulated unsheathed earth wire with multistranded copper conductor of size 1.50 sqmm pressed steel modular boxessunk on wall for mounting of modular switches, switch sockets, fan regulator etc including modular coverwith frame any size complete all as specified and making good disturbed surfaces for one light point controlled by one, one way switch. Note:- Cost of cable provided from sub main DB to respective switch board in rooms shall be included in the quoted point wiring rate. All switches, fan, sockets, ceiling roses and holders shall be connected to common earth dolly.
33S&F modular switch single pole one way 6A, 1 module, 250 volts AC suitable for modular switch boxes complete all as specified and directed.
34S&F ceiling rose 3 phase PVC/polycarbonate, isolated body complete all as specified and directed.
35S&F exhaust fan 300mm sweep, metallic body, single phase, 230 volts, 50 Hz with nuts and bolts, washers etc and louver shutters, connecting up with twin core twisted flexible copper conductor cable of suitable size from fitting to ceiling rose complete all as specified and directed.
36M&L for making hole of suitable size for 300mm sweep exhaust fan and including grouting bolts, cutting chasing and plastering etc to match with the existing surface complete all as specified and directed.
37NOTE:- SCHEDULE OF CREDIT (Amount shall be deducted offline from the total quoted amount to workout the net contract sum to be considered for acceptance.) [(-) Rs.30,580.00]