Supply And Installation Of 12.5 Mtr Led High Mast And Repairing Of Two Old High Mast Lights At Ia Chakeri Kanpur
Tender Value
31.02 Lakhs
Estimated cost
Bid Submission
19 Oct 2022
0 days left
EMD
62100
Bank guarantee accepted
Document Fee
2136
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
chakeri → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Supply And Installation Of 12.5 Mtr Led High Mast And Repairing Of Two Old High Mast Lights At Ia Chakeri Kanpur
BOQ
| Sl. No. | Item Description |
| 1 | Supply & fixing of 12.5 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 3 mm. Top dia minium 150 mm, Bottom dia 310 mm base plate 25 mm thick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories for high mast such as head frame suitable for 6 luminaries & its control gear boxes 0.75 HP power tool moter, 3 point suspension system with steel wire rope 6 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect.. as per UPPWD Sch. No.651 BAJAJ/CROMPTON/PHILIPS/WIPRO MAKE ) |
| 2 | Supply and fixing 25amp.TPN Capacity of Automatic street light cubicle control panel painted with Anti corosive alkali and acid proof paint, consisting of time switch TSO 100 serices with ML-4 Contractor (L&T) make, HRC Fuses Isolating switch, metering Instrument & Instrument box with C.T. etc. Complete in all respect\"s.as per UPPWD Sch. No.807(e)(ii) |
| 3 | S/B of 40 mm dia x 4.5 mtr. Long GI pipe vertical for earthing having 12 mm dia. Holes spaced 75 mm apart drilled upto 2 mtr. From the bottom complete with earthing lead of no. 6 to 8 SWG GI wire in GI pipe upto appron upto switch board 30 CM square box with hinged cover masonary enclosure. Funnel of top, alternate layers of charcoal and salt at least 150 mm thick alround etc. as per direction E/I complete in all respect as per drawing as per UPPWD Sch. No. 701 |
| 4 | Supply & wiring of submain with 2 Nos. of 2.5 sqmm FRLSH PVC insulated 1100 V grade single core multistrand copper conductor cables in existing conduit complete with supply of all material labour and T&P reuired for proper complation of the work as directed as site byEngineer I/C as Per UPPWD sch No. 289(KEI / GRANDLEY/POLYCAB/GLOSTER /HAVELLS MAKE) |
| 5 | S/F of palm or pin type copper tin plated cablesocket (lug) to the cable leads insulating with tap and making connection etc. complete in all respect as per direction of the Engineer- incharge as per UPPWD sch. No. 504 (d) 16 sq. mm |
| 6 | Supply & laying 16 sq mm 4 core Al. conductor PVC insulated armoured, served, sheated cable 1100 V garade in existing HDPE pipe laid below ground level. The armouring of the cable shall be properly connected with earth conductor by clamp etc. as per PWD Sch. 501 (i) & 507(KEI / GRANDLEY/POLYCAB/GLOSTER /HAVELLS MAKE) |
| 7 | Sypply & laying of 90 mm dia DWC HDPE pipe ISI marked along with all accessories likesocket, bend, couple etc. confirming to IS 14930 Part-II complete with fitting and cutting, jointing etc. direct in ground (75 cm delow ground level ) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. complete as per DSR Sch. No. 14.16.2 |
| 8 | Supply and fixing of 150 watt factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for confirming to IP 66 protection complete in all respects. For 12.5 Mtr New High Mast / 16 Mtr Old High Mast (30 no. + 20 No. ) Catt. AA as per UPPWD Sch. No.1454 (BAJAJ/CROMPTON/PHILIPS/WIPRO MAKE ) |
| 9 | Supply and fixing of 200 watt factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for confirming to IP 66 protection complete in all respects. Catt. AA as per UPPWD Sch. No.1455 (BAJAJ/CROMPTON/PHILIPS/WIPRO MAKE ) |
| 10 | S/F of wiring Cable(3Cx1.5 Sq.mm copper wire) for High Mast lighting system complete including all T&P men and material required for proper completion of work. |
| 11 | Painting of ST pole and all mountings on it with two coats of aluminium paints with an under coat of red oxide paint on length of above 10 M. support above the ground level as per direction of Engineer in-charge of work/site including T&P , men & material required for proper completion of work.UPSIDC Sch. No.20.2 |
| 12 | Dismentling & Re-installation of 16 Meter high mast lighting system including labour, T&P, men & material complete in all respects as per direction of Engineer-in-charge. |
| 13 | S/F of S.S. wire rope set for High Mast lighting system complete including all T&P men and material required for proper completion of work. |
| 14 | S/F of Trailing Cable for High Mast lighting system complete including all T&P men and material required for proper completion of work. |
| 15 | S/Oiling of winch machine forHigh Mast lighting system complete including all T&P men and material required for proper completion of work. |
| 16 | S/F of Male -Female plug & socket for High Mast lighting system complete including all T&P men and material required for proper completion of work. |
| 17 | Lowring of 16 Mtr. High mast lighting system complete in T&P men & material required proper completion of work etc. |
| 18 | S/Fhead frame Of 16 Mtr Highmastsuitable for 8 to 12 luminaries complete in T&P men & material required proper completion of work etc. |
AI Tender Summary
Tender Timeline
Oct 01, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedOct 19, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 20, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender