Providing Water Supply Scheme Village Kotli Shah Habib And Nawan Panj Garrian Mh Block Ajnala Distt Amritsar. Under-Jal-Jeevan-Mission -And-Prwssip-2A-I, amritsar-Punjab

Water Supply And Sanitation Department-WSSD has published Providing Water Supply Scheme Village Kotli Shah Habib And Nawan Panj Garrian Mh Block Ajnala Distt Amritsar. Under-Jal-Jeevan-Mission -And-Prwssip-2A-I. Submission Date for this Tender is 17-10-2022. Water Supply Project Tenders in amritsar Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

34207763
Providing Water Supply Scheme Village Kotli Shah Habib And Nawan Panj Garrian Mh Block Ajnala Distt Amritsar. Under-Jal-Jeevan-Mission -And-Prwssip-2A-I
Open Tender
Indian
Punjab
amritsar
17-10-2022

Tender Details

Providing Water Supply Scheme Village Kotli Shah Habib And Nawan Panj Garrian Mh Block Ajnala Distt Amritsar. Under-Jal-Jeevan-Mission -And-Prwssip-2A-I

Key Value

Document Fees
INR 500 /-
EMD
INR 27000.0 /-
Tender Value
INR 13.37 Lakhs /-

BOQ Items

Name of Work:- Water Supply Scheme Village Kotli Shah Habib & Nawan Panj Garrian (MH) Block Ajnala Distt Amritsar. (UNDER JAL JEEVAN MISSION+PRWSSIP 2A(I)) Providing House Connection for existing pipe line & new Pipe Line Prov.& Layingjointing, testing PVC pipe 6kg/cm2,specials for Distribution System, Sluice valve, Chamber, Replacement of Pumping Machinery,Prov. & installing panel board, , Repair of Pump Chamber, Repair of OHSR& Development of water works etc. & All other works Contingent there to Complete in all respect.
Sl. No. Item Description
1Providing & Installing Testing & Commissioning of One No. Electrically driven Submersible Pumping set (5.00 BHP) of reputed Make capable of delivering 119 LPM against a head of 67 mtr complete in all respects as per standard Specifications. After credit of old machinery
2Cost of submersible cable Supply and erection of PVC insulated PVC sheathed (3 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- Overall size 2.5sq.mm (50/0.25mm), 3Core
3Providing & Fixing Submersible column pipe Size 40mm dia Complete In all respect.
4Providing and Fixing of new Control Panel consisting of electric appliances such as automatic Star Delta Push Button or oil immersed Starter, Main Switch, VM, Ampere Meter, ELCB, Shunt Capacitor, Single Phase preventer, Indicating Lamps, Kit-Kat etc. (reputed make) complete in all respects as per standard Specifications.
5REPAIR OF PUMP CHAMBER
6Hollock wood doors shutter windows shutter including hinges, screws, chocks, cheats, stops cords etc. complete fixed in position. i) 40mm thick Door (ii) Windows
7Applying pink primer or aluminum priming coat on wood work including preparation of surface knotting and stopping etc.
8Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
9Applying priming coat with metal primer on new steel or ironwork including preparation of surface.+Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade.
10Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapetall finished smooth, where specially specified.
11White washing 3 coats inside of pump chamber.
12Finishing walls withcement based water soluble exterior paint such as snowcem, robbiacem etc. two or more coats to give an even shade
13Preparation of plastered surfaces for distempering including surface, applying filling withapproved quality filler consisting of plaster of paris and chalk mitti including finishing the surface to the required finish complete
14Supplying and fixing glass panes with glazing clips and special metal sash putty of approved make.Glass panes 4mm or 10.75 kg / sqm exceeding 0.4 sqm of area
15Providing orange colour safety footrest of minimum 6mm thick plastic encapsulated as perIS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturer"s permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
16RECESSED HGW CONDUIT PIPE WIRING SYSTEM WITH FLUSH PIANO TYPE SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge welded conduit pipe 20mm/ 25mm dia (1.6mm thick) ISI Marked recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for having (Flush/ Piano type accessories) Step type electronic fan regulators 100watts (socket size), bell push, 5Pin 6Amp. sockets (4Module Box), 16Amp. universal sockets (6Module Box), 6/16/20Amp. Switches etc. and covered with brown bakelite white glazed translucent backside painted sheet 3mm thick etc., PVC connector (For Fan Box and Call Bell), PVC Bush, Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), CI Circular junction Boxes (Four way 1½" deep for walls and 3" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost ofabove material, cutting and filling up of chases (with finishing the surface):-
17Wiring fan point (Without fan box)
18Wiring light point
19Wiring 6Amp. Plug control comprising wall socket point.
20Wiring 16/20Amp. power plug control point
21Repair of OHSR
22Providing & Fixing OHSR Top Jali complete in all respects
23Repair of Expansion joints Complete in all respects (100 mm i/d)
24Providing,Fixing and testing at site automatic electronic type water level indication system with gun metal float sensor and electrical cable suitable for three phase pump submersible/monoblock to be fixed on existing panel for OHSR complete in all respect.
25Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) 100mm I/d
26REPAIR OF WATER WORKS
27Providing & fixing G.I. Barbed wire 3 ply fencing around the head works site in three rows complete in all respects including cost of winding wire & aluminum painting complete in all respects as per standard Drawing.
28Providing & Fixing PCC Fencing Poles With 6" height, 3" x 3" Top & 4" x 3" Base provided with 3 nos. hooks complete in all respects.
29Providing & fixing D.Hook complete with MS Bolts size 300mm x 18mm as per standard Drawing D-7.
30Construction of brick masonry corner pillar including cost of cement pointing including cost of material complete in all respects as per standard Drawing D-3.
31Providing & fixing MS Sign Board as per standard size of DWSS as per Drawing D-20
32Construction of masonry gate pillar including cost of MS Steel Gate size 1.22mtr x 1.37 mtr as per standard Drawing with including D-4 & Analysis A-4 complete in all respects
33Construction of foot paths with masonry toe wall& earth filling & concrete topping; inside water works as per standard drawing D-10 & Analysis of Rates A-11 complete in all respects.
34Providing & Installing Testing & Commissioning of One No. Electrically driven diaphragm opreated metering system chemical dosing chlorinator suitable for for delivering 0.5 to 6 liters of Bleaching Powder solution/ Sodium Hypo solution per hour under maximum delivery pressure upto 7 Kg/cm2 and suction left not less than 1.5 mtr., as per DWSSstandard specifations.
35Connection with existing PVC pipe including cost of Bailing out, D-jointsand earth work in excavation & back filling .etc complete in all respect .
36Providing, Laying , fixing & jointing ofP.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (Manually) (6kgf/cm2) (excavation & including specials)
37PVC Pipe 63mm o/d
38PVC Pipe 75mm o/d
39Providing, Laying , fixing & jointing ofP.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. (Mechnically) (6kgf/cm2) (excavation & including specials)
40PVC pipe 63mm o/d
41PVC pipe 75mm o/d
42PVC pipe 90mm o/d
43Providing and laying, jointing, fixing, testing ISI Marked G.I. Pipe (as per IS 1239) BClass, including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground complete.
4425 mm i/d
4532 mm i/d
46Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) 80mm I/d
47Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) 100mm I/d
48Construction of masonry sluice valve chamber excluding Sluice valve cover as per standard design & drawings of public health department. Size 0.6m x 0.6m
49Dismantling brick or flagged stone flooring without concrete base and relaying of dry brick on edge paving with a dismantled bricks including sand grouting.
50PVC pipe 63mm o/d
51PVC pipe 75mm o/d
52PVC pipe 90mm o/d
53Dismantling and restoration of Cement Concrete Flooring comlete in all respects.
54Providing proposed water connections to household up to wall with providing ,laying, jointing, fixing, testing MDPE pipe line 15 mm i/d = (Below GL) andISI Marked G.I. Pipe 15 mm i/d (As per IS 1239)B-Class approved make =(Above GL) including cost of Specials such as tees, bends, sockets elbow etc., cutting, threading and testing in trenches in the ground and ISI marked 15 mm i/d GM Ferrule as per IS:2692 and 3" i/d clamp with CI Bib Cock 15 mm i/d as per IS:210 with stainless steel spindle of approved make as per CSR 30.65(b) complete in all respects. Connection at New pipe line)=45 Nos
55Hand boring Horizontly for crossing of pipe under road or any other obstacle by Auger/Bocki method. Including excavation, stringing and jointing of pipe upto 160mm complete.
56Carriage Cost of Fine Aggregate
57Carriage Cost of Course Aggregate
58CONDITIONS :-
59Item for which no rate or price has been entered in will not be paid for the Employer when execut6ed and shall be deemed covered by the other rates and prices in the Bill of Quantities.
60Unit rates and prices shall bequated by the bidder in indian ruppees.
61Where there is a discrepancy between the rate in figures and words, the rates in words will govern.
62Where there is a discrepancy between the rate and the line total resulting from muluplying the unit rate by quantity the unit rate quoted shall govern.
63Any item of work not included in the above contract schedule of rates and got done at the site of work; the same will be paid according to CSR-2010 subject to the premium or discount tendered by the contractor. In the case of non-schedule items, the decision of the Engineer-in-charge will be final and binding upon the contractor. In case any item which is a part of lump-sum rate isbe deducted @CSR rates + Ceiling premium prevailing on the date of tender
64The work will be carried out in accordance with PWD Book of specifications - 1963 edition with upto date amendments.
65Approximate quantities are given in the contract schedule of rates and these can vary at the time of execution of the work. The payment will be made according to the actual work done by the contractor.
66All amendments issued on the common schedule of rates 2010. up to the date of opening of tenders will be applicable on the contract schedule of rates.
67Contractor should clearly quote his rates in figures & words. Conditional tender will be rejected.
68All items and rates provided in the DNIT are subject to the footnotes give in CSR-2020
69The Engineer-in-charge will have full powers to change the layout of the work covered in this contract if considered necessary.
70No claim will be entertained form the contractor in case, any mistake in description rates or unit occurs in any item taken in this schedule while preparing this DNIT or on account of typing or comparison or over writing. The same will be rectified at any time as per common schedule of rates 2010 along with upto date amendments.
71The arrangements of bricks at site of work would be done by the contractor at his own level from his own source.
72For any other non-schedule items, the contractor will submit through Engineer-in-charge, the analysis of rates in triplicate based on purchased vouchers. A margin of 10% shall be allowed for material components and 21.5% on labour components and contractor shall produce photo stat copies of the purchase vouchers in support of his claim. The decision of the Engineer-in-charge/Competent authority in the matter shall be final and binding on the contractor.
73All the extra items will be got approved from the competent authority and no premium will be allowed on non schedule item
74Pavement for the carriage of material shall be paid as per the rates quoted by the tenderer.
75Time period allowed for completion of work in 3 months.
76If contractor allowed for completion of work within 7 days from the date of allotment, DWSS reserve the right to impose penalty or withdraw the work and propose action for debarring in future tendering or both; decision of Chief Engineer (North) shall be binding.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail