Provision Of Pre Paid Electric Meter Phase Ii For Md Accn At 19 Wing Under Ge ( Af ) Borjhar, borjhar-Assam

Military Engineer Services-MES has published Provision Of Pre Paid Electric Meter Phase Ii For Md Accn At 19 Wing Under Ge ( Af ) Borjhar. Submission Date for this Tender is 07-11-2022. Energy Meter Tenders in borjhar Assam. Bidders can get complete Tender details and download the document.




Tender Notice

34188378
Corrigendum : Provision Of Pre Paid Electric Meter Phase Ii For Md Accn At 19 Wing Under Ge ( Af ) Borjhar
Open Tender
Indian
Assam
borjhar
07-11-2022

Tender Details

Provision Of Pre Paid Electric Meter Phase Ii For Md Accn At 19 Wing Under Ge ( Af ) Borjhar

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Oct-2022 Date corrigendum Date 31-10-2022
2 28-Oct-2022 Other Other 31-10-2022
3 31-Oct-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 07-11-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 48520.0 /-
Tender Value
INR 24.26 Lakhs /-

BOQ Items

Name of Work: PROVN OF PRE-PAID ELECTRIC METERS (PHASE-II) FOR MD ACCN AT 19 WING UNDER GE (AF) BORJHAR
Sl. No. Item Description
1Taking down old energy meter of any watt or phase, segregate the seviceable and unserviceable meters and deposit to MES Store Yard complete all as specified and as directed.
2Supply, installation, testing & commissioning of single phase, two wire single source direct connected LCD display type microprocessor based smart energy meter (functioning as prepaid mode), 230/240 volt, 5 -60 Amps or 10 - 60 Amps , acuracy class 1.0, frequency 50 Hz (Electric Meter marked as "PROPERTY OF MES"), conforms to IS-16444 : 2020, IS 15959 : 2011, IS 15884 :2010 & IS 13779 :1999 with latching relay for meter protection, dual mode support (credit/ prepay), in build billing data calculation facilities with IP 54 transparent polycarbonate meter box with all standerd anti-temper features and sealing facility and should have synchronisation system with existing prepaid meter system complete all as specified and as directed. Make : L&T/Secure Meters/HPL/Schneider Note:- The contractor shall submit manufacturer"sunconditional warranty for 10 (ten) years for any type of defects/damaged in the meter.
3Supply, installation, testing & commissioning of three phase, four wire single source direct connected LCD display type microprocessor based smart energy meter (functioning as prepaid mode), 240 volt (L-N), 10 - 100 Amps, acuracy class 1.0, frequency 50 Hz (electric meter marked as "PROPERTY OF MES"), conforms to IS 16444 : 2020, IS 15959 : 2011, IS 15884 :2010 & IS 13779 :1999 with latching relay for meter protection, dual mode support (credit/ prepay), in build billing data calculation facilities with IP 54 transparent polycarbonate meter box with all standerd anti-temper features and sealing facility and should have synchronisation system with existing prepaid meter system complete all as specified and as directed. Make : L&T/Secure/HPL/Schneider Note:- The contractor shall submit manufacturer"sunconditional warranty for 10 (ten) years for any type of defects/damaged in the meter.
4M&L for charges for comprehensive vending transaction which include for issue of token in prepaid mode via SMS or App facility, 24x7 customer support in Toll Free number, reconfiguration of software in replaced meters for each supplied meters on yearly basis to be paid in advance for two years and as directed. Note:- Contractor shall submit necessary supporting documents from OEM before taking any payment from department.
5M&L for creation consumer and meter management module with unlimited metering points set up, tariff management module, occupation and vaccation module, preparation of consumer app and website, communication module from MES to consumer, preparing admininistration management system, providing training to MES personnel & consumer and installation of software etc incl maintenance of the same for two years etc complete all as specified and as directed.
6M&L for wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 6.0 Sq.mm 1100 volts grade drawn through in and including PVC conduit (medium grade) (or through stainless steel flexible conduit of size 20mm if required) withall accessories for meter connection and making good disturbed surfaces as per existing and complete including taking down old one complete all as specified and as directed. Note:- No PVC flexible conduit shall be allowed to use.
7M&L for wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 10.0 Sq.mm 1100 volts grade drawn through in and including PVC conduit (medium grade) (or through stainless steel flexible conduit of size 25mm if required) withall accessories for meter connection and making gooddisturbed surfaces as per existing and complete including taking down old one complete all as specified and as directed. Note:- No PVC flexible conduit shall be allowed to use.
8M&L for wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable (FRLSH) of size 16.0 Sq.mm 1100 volts grade drawn through in and including PVC conduit (medium grade) (or through stainless steel flexible conduit of size 25mm if required) with all accessories for meter connection and making good disturbed surfaces as per existing and complete including taking down old one complete all as specified and as directed. Note:- No PVC flexible conduit shall be allowed to use.
9M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 6.0 Sq.mm 1100 volts grade and onerun of PVCinsulated unsheathed multistranded copper conductorcable of size6.0 Sq.mm 1100 volts grade as earthcontinuity conductor drawn through in and including DLP UPVC trunking of 32x12.5mm size incl. all finishing accessories onroof /wall /ceiling etc complete and making good of wall/floor with cement plaster in cement mortar(1:6) and distempering /white washing to match the existing surface complete including taking down old one complete all as specified and as directed. Make-: PVC Trunking- Legrand/L&T/Siemens /Schneider Note:- No PVC flexible conduit shall be allowed to use.
10M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 10.0 Sq.mm 1100 volts grade and onerun of PVC insulated unsheathed multistranded copper conductorcable of size6.0 Sq.mm 1100 volts grade as earth continuity conductor drawn through in and including DLP UPVC trunking of 32x12.5mm size incl. all finishing accessories onroof /wall /ceiling etc complete and making good of wall/floor with cement plaster in cement mortar(1:6) and distempering /white washing to match the existing surface complete including taking down old one complete all as specified and as directed. Make-: PVC Trunking- Legrand/L&T/Siemens /Schneider Note:- No PVC flexible conduit shall be allowed to use.
11M&L for sub main wiring with two run of single core PVC insulated unsheathed multi stranded copper conductor cable of size 16.0 Sq.mm 1100 volts grade and one run of PVC insulated unsheathed multistranded copper conductorcable of size6.0 Sq.mm 1100 volts grade as earthcontinuity conductor drawn through in and including DLP UPVC trunking of 32x12.5mm size including all finishing accessories on roof /wall /ceiling etc complete and making good of wall/floor with cement plaster in cement mortar(1:6) and distempering /white washing to match the existing surface complete incl taking down old one complete all as specified and directed. Make-: PVC Trunking- Legrand/L&T/Siemens /Schneider Note:- No PVC flexible conduit shall be allowed to use.
Disclaimer :