Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Construction of Main Building |
| 2 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 3 | Providing and applying Anti Termite Treatment using pre constructional chemical treatment measures as per IS - 6313 - 2001 ( Part 2 ) & using Chemical containg chloropyrifos systemic insecticide diluted to manufacturer\"s specifications (i) In foundation pits, by treating the bottom & sides upto height of 300mm by uniformly spraying solution @ 5 Litre / Sqm (ii) In the refill earth on both sides of all built up walls @ 7.5 Litre / Running meter ( width - 300 mm, depth- 450 mm ) (iii) Before laying the floor, by uniformly sprinkling the top surface of the consolidated earth within the outer perimeter @ 5 Litre solution per Sqm. |
| 4 | Cement concrete 1:5:10 with 40 mm gauge stone ballast.using concrete mixing volumetric type |
| 5 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 6 | Damp proof course 4 cm thick of cement concrete 1 : 2 : 4 with 2 coats of bitument 20/30 penetration at 1.65 kg per Sqm. laid hot and sanded. |
| 7 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 8 | Lintels |
| 9 | Ground Floor |
| 10 | First Floor |
| 11 | Extra rate for First Floor |
| 12 | Shelves |
| 13 | Ground Floor |
| 14 | First Floor |
| 15 | Extra rate for First Floor |
| 16 | Reinforced cement concrete M-25 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 17 | Slab |
| 18 | Ground Floor |
| 19 | First Floor |
| 20 | Extra rate for First Floor |
| 21 | Second Floor |
| 22 | Extra rate for Second Floor |
| 23 | Beams |
| 24 | Ground Floor |
| 25 | First Floor |
| 26 | Extra rate for First Floor |
| 27 | Columns |
| 28 | Ground Floor |
| 29 | First Floor |
| 30 | Extra rate for First Floor |
| 31 | Second Floor |
| 32 | Extra rate for Second Floor |
| 33 | Lift Walls |
| 34 | Ground Floor |
| 35 | First Floor |
| 36 | Extra rate for First Floor |
| 37 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 38 | Centring and shuttering for flat surfaces such as suspended floors, roofs, landings, chajjas, shelves etc. |
| 39 | Ground Floor |
| 40 | First Floor |
| 41 | Extra rate for First Floor |
| 42 | Second Floor |
| 43 | Extra rate for Second Floor |
| 44 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels |
| 45 | Ground Floor |
| 46 | First Floor |
| 47 | Extra rate for First Floor |
| 48 | Centring and shuttering for columns (Square or rectangular or poly gonal in plain) |
| 49 | Ground Floor |
| 50 | First Floor |
| 51 | Extra rate for First Floor |
| 52 | Second Floor |
| 53 | Extra rate for Second Floor |
| 54 | Centring and shuttering for faces of walls, partitions, retaining walls and the like (vertical or bartering including attached pillasters buttersses etc |
| 55 | Ground Floor |
| 56 | First Floor |
| 57 | Extra rate for First Floor |
| 58 | Centring and shuttering for stair cases with sloping with soffits including risers and stringers. |
| 59 | Ground Floor |
| 60 | First class burnt brick work laid in cement sand mortar 1:6 in foundation and plinth. |
| 61 | First class burnt brick work laid in cement sand mortar 1:6 in first storey upto 4 metres above plinth level.. |
| 62 | Ground Floor |
| 63 | First Floor |
| 64 | Extra rate for First Floor |
| 65 | Second Floor |
| 66 | Extra rate for Second Floor |
| 67 | Third Floor |
| 68 | Extra rate for Third Floor |
| 69 | 115 mm thick brick wall with every fourth course reinforced with hoop iron laid in 1 :4 cement sand mortar in super structure. |
| 70 | Ground Floor |
| 71 | First Floor |
| 72 | Extra rate for First Floor |
| 73 | 12.5mm thick cement plaster 1:5. |
| 74 | 20 mm thick cement plaster 1:5 in two coats work. |
| 75 | 12.5 mm thick cement plaster 1:4. |
| 76 | Extra rate for Smooth Surface of Ceiling. |
| 77 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes (working pressure 4 kgf / cm²) conforming to IS : 4985, including fixing with MS ClampU-PVC pipes (working pressure 4kgf. / sqcm)pipe 110 mm dia. |
| 78 | Providing and fixing 110 mm dia. U.P.V.C bend for Rain water pipe as per IS:14735 including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge.UPVC 110 mm bend |
| 79 | Providing and fixing 110 mm dia SWR U.P.V.C Coupling/Sockete for Rain water pipe as per IS:14735including jointing complete as per specifications and to the entire satisfaction of Engineer- in- charge. |
| 80 | Top khurra 0.6m x 0.6m for rain water pipe in 25mm thick cement concrete 1:2:4 over 50mm thick cement concrete 1:8:16. |
| 81 | Bottom Khurra on ground 1.2m. x 0.6m. consisting of brick on-edge laid in cement mortar 1:3 over 75mm cement concrete 1:8:16 including 12.5m.m. thick cement plaster 1:3. |
| 82 | Providing and fixing in position gratings 150mm x 150mm for gully trap.PVC grating |
| 83 | Terracing consiting of tiles 22.86x11.43x3.83cm laid over 25 mm mud plaster 7.5 cm mud filling on another layer of 25mm mud plaster including two coats of bitumen laid hot at 1.65 Kg. /Sqm top of R.C.C. slab including grouting with cement sand mortar 1:4 and top surface to be left clean after wire brushing |
| 84 | First Floor |
| 85 | Extra rate for Second Floor |
| 86 | Second Floor |
| 87 | Extra rate for Second Floor |
| 88 | Cement concrete 1:2:4 gola 10cm x 10cm concave quadrant along junction of roofs with parapet wall finished smooth, where specially specified. |
| 89 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate z sections and other sections conforming to Is: 733 and IS : 1285 of Jindal, Hindalco, Mahavir or equivalent make approved by Engineer in Charge , fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions, at top, bottom and sides with required PVC Plug/neoprene felt etc. Aluminium sections shall be smooth, rust free, straight, mitered and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/paneling, C.P.brass/stainless steel screws, all complete as per architectural drawings and the directions of Engineer-In-Charge. (Glazing and paneling to be paid for separately) : |
| 90 | For fixed portion & Chaukhat |
| 91 | For shutters of doors, windows & ventilators including providing and fixing hinges/pivots and labour for fixing of fittings wherever required including the cost of PVC Plug / neoprene gasket required |
| 92 | Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in paneling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer-In-Charge. Prelaminated particle board with decorative lamination on one side. |
| 93 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with PVC Plug/ neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item) |
| 94 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, for doors including cost of cutting floors as required, embedding in floors and cover plates with brass pivot and single piece MS sheet outer box with slide plate andwith stainless steel cover plate etc. complete as per the direction of Engineer-in-charge. |
| 95 | Providing Polyster Powder coating 50 micron any coloured specrified to aluminium section of various sizes including carrriage of material from marktet to workshop . |
| 96 | Providing and fixing hydraulic door closer ISI mark with necessary screw etc. completeI.S.I Designation No. 1 (size of door up to 700mm) |
| 97 | Earth filling with good quality earth obtained from out side the plinthincluding compensation of earth, loading, unloading, carriage from outside the peremises to site of work, spreading, laying watering compactingwithrammer complete as per specifications. |
| 98 | Earth filling under floors with surplus ordinary soil or soil containing gravel or kankar upto40% excavated from foundation and taken only from outside the building plinth in 15 cm layers including ramming, watering and consolidating lead upto 30 metres. |
| 99 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 100 | Ground Floor |
| 101 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material |
| 102 | First Floor |
| 103 | Extra rate for First Floor |
| 104 | Kota stone slab 20-25 mm thick flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :. |
| 105 | Ground Floor |
| 106 | First Floor |
| 107 | Extra for First Floor |
| 108 | Kotah stone tiles 20mm thick in skirting risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing |
| 109 | Ground Floor |
| 110 | First Floor |
| 111 | Extra for First Floor |
| 112 | Providing and laying vitrified floor tiles indifferent sizes in light colour shades made using Full Body Technology (thickness to be specified by the manufacturer) with water absorption’s less than 0.08% and conforming to IS : 15622 of approved make in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement: 4 fine sand), complete. ( Full body vitrified tiles havepigment in entire body / thickness of tile which makes chips and scratches less noticeable and make na ideal choice for high traffic zones.)Size 600x600 mm |
| 113 | Ground Floor |
| 114 | First Floor |
| 115 | Extra for First Floor |
| 116 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. |
| 117 | Ground Floor |
| 118 | First Floor |
| 119 | Extra for First Floor |
| 120 | Extra labour for projected nosing of stair case of any shape and design |
| 121 | Providing and fixing Morwad Marble Strip 12mm to 15mm thick and 100 mm wide in kotah stone flooring over 12.50mm thickness base of cement mortar 1:3 jointed with cement slurry including cost of additional mortar equivalent to the kota stone thickness andcolouring pigment to match the colour rubbed and polished to granolithic finish complete in all respects.respects. |
| 122 | Precast chequered tiles of 20mm thickness in ordinary grey cement without chips laid on 20mm thick bed of cement mortar 1:3 with neat cement slurry between joints and over the base in floors, treads of steps on landings. |
| 123 | Ground Floor |
| 124 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 125 | Providing Polyester Powder coating 60to 70 micron any coloured specified to M.S Grill section of various sizes including carriage of material from market to workshop & workshop to site of work. |
| 126 | Providing and fixing stair case railing made out of M.S. square bars 20mm x 20mm as vertical part 0.70 m high fixed with M.S. base plate of 40mm x 40mm x 6mm and flat iron 40mm x 6mm as hand rail complete in all respect. |
| 127 | Providing & fixing 16 guage stainless steel pipe railing of grade 304 duly fixed on steps with the help of bolts grouted on steps with hand rail and newel post of 50mm dia Stainles steel pipe, Balusters of 40mm dia stainless steel pipe complete in all respects. |
| 128 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete |
| 129 | Ground Floor |
| 130 | First Floor |
| 131 | Extra rate for First Floor |
| 132 | Second Floor |
| 133 | Extra rate for Second Floor |
| 134 | Cost of Aluminium fittings complete for doors, windows such as tower bolts, handless and screw etc. for these fittings (Excluding sliding bolt)For shutter area above 0.50 sqm |
| 135 | Providing and fixing aluminium sliding door bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with nuts and screws etc. complete :300mm x 16mm |
| 136 | Providing and applying plaster of paris (ISI marked such as JK, Kohinoor, Maharaja etc.) punning 6mm thickness over plastered surface to prepare the surface even and smooth complete in all respect as per the directions of Engineer-in-charge. |
| 137 | Preparation of plastered or concrete surface for painting (including sand papering the surface) using ready mixed cement based wall putty by applying two or more coats to getrequired finish |
| 138 | Distempering with Acrylic washable oil bound distemper (of approved manufacture) two coats over one priming coat to give an even shade. |
| 139 | Applying priming coat with metal primer on new steel or iron work including preparation of surface. |
| 140 | Painting two or more coats excluding priming coat with ready mixed paint for metallic surfaces in all shades on steel or iron work |
| 141 | Finishing walls with Premium Acrylic smooth exterior paint with silicon additives of required shade with two or more coats applied @ 1.43litre/10 Sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 Sqm |
| 142 | Construction ofPlinth protection complete as per drawing. |
| 143 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 144 | Cement Concrete 1:8:16 with 40mm guage stone aggregate using concrete mixing volumetric type |
| 145 | 115 mm thick brick wall laid in cement mortar 1 :4 without reinforcement in foundation and plinth. |
| 146 | Earth filling with good quality earth obtained from out side the plinthincluding compensation of earth, loading, unloading, carriage from outside the peremises to site of work, spreading, laying watering compactingwithrammer complete as per specifications. |
| 147 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate and 100mm sand filling(Using mechanical mixer for mixing of material) |
| 148 | Conglomerate floor 40mm thick cement concrete topping 1:2:4(Using mechanical mixer for mixing of material). |
| 149 | 12.5 mm thick cement plaster 1:5complete in all respect as per specifcation, drawing andto theentire satisfication of Engineer-In-Charge. |
| 150 | Outer Infrastructure |
| 151 | Construction of Boundary Wall With Grill |
| 152 | Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm. layers with compaction including disposal of all surplus soil as directed within a lead of 30 metres. |
| 153 | Cement concrete 1:5:10 with 40 mm gauge stone ballast.using concrete mixing volumetric type |
| 154 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 155 | Reinforced cement concrete M-20 mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth. |
| 156 | Shuttering for faces of concrete foundations and foundation beam & plinth beam (vertical or battering) |
| 157 | Reinforced cement concrete M-20mechanicaly batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in supersturcture. |
| 158 | Centring and shuttering for Columns ( Square or Rectangular or ply gonal in plain) |
| 159 | Centring and shuttering for sides and soffits of beam, beams launchings girders bressumers, lintels |
| 160 | Cold twisted deformed (Ribbed/ Tor Steel Bar/TMT) Bars Fe 500 grade as per IS 1786-2008, for R.C.C works, where not including in the complete rate of RCC including bending and placing in position complete |
| 161 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 162 | 12.5 mm thick cement plaster 1:4. |
| 163 | Wrought iron and mild steel ladders, framed grills, grating etc. with ends of bars, riveted or welded or forged, framed window guards, barred iron doors, stair case, iron railing including cost of bolts and nuts or screws or welding rod, complete fixed in position. |
| 164 | Iron grated doors, including pintle hinges and arrangements. |
| 165 | Finishing walls with Premium Acrylic smooth exterior paintwith silicon additives of required shade with two coats applied @ 1.43litre/10 sqm over and including base coat of water proofing Cement Paint applied @ 2.20 Kg/10 sqm |
| 166 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 167 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 168 | Construction of Internal Concrete Roads, Pavements with Pavers & foot Path |
| 169 | Earth filling with good quality earth obtained from out sideincluding compensation of earth, loading, unloading, carriage from outside the peremises to site of work, spreading, laying watering compacting with road roller complete as per specifications. |
| 170 | Cement Concrete 1:4:8 with stone ballast of size. 40 mm guage. using concrete mixing volumetric type |
| 171 | Construction of unreinforced plain cement concrete pavement in M-30 mix design over a prepared sub base with OPC 43 grade conforming to IS:383 mixed with concrete mixer using batch type concrete mixer as per IS:1791, laid in position, compacted with needle vibrator, screed vibrator and plate vibrator, dewatering of free water with vaccum pump, finishing the surface with power floater, finishing to required lines and grades as per drawings and technical clause 1501 of MORD specifications |
| 172 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufacturedby block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in-Charge. |
| 173 | Extra Cost for using darker fast shade for interlocking pavers Tiles of any shape & thickness instead of grey colours. |
| 174 | Plain cement concrete M-20 grade precast kerb 250mm high with bottom width 165mm and top width 115mm fixed in position including carriage to site of work complete as per technical clause 408 of MORT&H specifications |
| 175 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 176 | Providing and Laying Out DoorPrecast Designer chequered tiles of any size & any shape 25mm thickness having top layer of white cement mixed with pigment, laid on 20mm thick bed of ordinary cement mortar 1:3(1 ordinary cement :3 fine sand), joints grouted with white cement slurrycontainingpigment to match the shade complete in all respect as per specifications and to the entire satisfaction of engineer- in- charge. |
| 177 | Applying priming coat with cement primer in all shade on newly plastered or concrete exterior surface |
| 178 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade. |
| 179 | Sub Work-1 Internal Water Supply, Sewerage, Sanitation |
| 180 | Sub Head-1 Internal Sewerage System |
| 181 | Providing and fixing in position singel socket SWR UPVC soil waste or antisyphonage pipes as per IS 13592 of E.D.C manufacture or of any other reputed firm including cutting, jointing, wastage, but excluding cost of jointing.Single Socket Type A |
| 182 | 110mm o/d single socket SWR UPVC pipe lines laid complete |
| 183 | 75mm o/d single socket SWR UPVC pipe lines laid complete |
| 184 | Providing and fixing in position SWR UPVC special for soil waste vent or anti syphonage pipes as per as per IS - 14735 including cutting and wastage etc. cutting holes in walls roofs or floors etc. and making good to its original condition but excluding cost of lead joining. |
| 185 | For 110mm i/d pipes |
| 186 | Elbow 90 Degree (All side socketed) |
| 187 | Coupler |
| 188 | P Trap/Floor Trap 110mm x 110mm |
| 189 | For 75mm i/d pipes |
| 190 | Coupler |
| 191 | Floor Trap 110mm x 75mm |
| 192 | Providing and fixing in position gully traps fixed in cement concrete 1:4:8 complete with Grating 150mm x 150mm, cover and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm and chamber including cost of all bricks work in cement morter 1:5 cement concrete 1:2:4 in coping around cover and frame etc.as per standard design minimumdepth of water should be 150 mm with a minimum seal 50mm. |
| 193 | 100mm internal Diametre S.W.gully trap with H.C.I. grating and cast iron cover weighing approximately 7.26 kg. and frame clear opening 300mm x 300mm and out of side size 330mm x 330mm |
| 194 | Construction of brick masonry inspection chambers size as given below upto 0.60 metre average depth in 1:5 cement sand mortar, C.C.1:4:8 ( 150mm thick) in foundation, cement concrete 1:2:4 benching 12.50mm thick cement plaster 1:2 with a floating coat of 1mm thick of neat cement, R.C.C. 1:2:4 slabs 100mm thick cement concrete topping 50mm thick with 455mm x 455mm, 455mm x 610mm inside R.C.C. inspection chamber cover and frame (Weightas per I.S.I specifications) painted with 3 coats of black bitumastic paint conforming to I.S.I complete as per standard design. |
| 195 | Size 450mm x 450mm inside with RCC 455mm x 455mm cover and frame light duty double seal |
| 196 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete. |
| 197 | uPVC Pipe 6 Kgf/cm250mm i/d |
| 198 | Sub Head-2 Internal Water Supply System |
| 199 | CONCEALED IN WALL: Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing including jointing of pipes & fittings, with one step CPVC solvent cement and testing of pipes complete as per direction of Engineer-in-Charge. |
| 200 | CPVC SDR 11 Pipe & fitting 16mm o/d |
| 201 | SDR 11 CPVC pipes & fittings 20mm o/d |
| 202 | CPVC SDR 11 Pipe & fitting 25mm o/d |
| 203 | Cutting holes upto 23cm square through B.B. in cement walls or stone masonary wall in cement for pipes, and making good the same & finishing according to existing finish where required. |
| 204 | Through wall 11.43 cm thick |
| 205 | Through wall 22.86 cm thick |
| 206 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879in G.I. Pipe lines complete in all respect. |
| 207 | 15mm i/d G.I. Union |
| 208 | 20mm i/d G.I. Union |
| 209 | 25mm i/d G.I. Union |
| 210 | Providing, fixing and jointing Brass Ball valves screwed with SS/BRASS ball & spindle & Teflon seats, on G.I. Pipe lines including all carriages complete. |
| 211 | 25mm i/d Brass Ball valves |
| 212 | Sub Head - 3 Sanitary Installation |
| 213 | Providing and fixing in position Chinaware Indian Orisa water closetsize 580 x 440 mm of approved make (to the approval of the Engineer-in-charge) consisting of10 ltr. PVC flushing cistern including cost of PVC long bend 32 mm dia complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 214 | Providing and fixing in position Chinaware European type water closet P trap or S trap of approved make (to the approval of the Engineer-in-charge) consisting of 10 ltr. PVC flushing cistern ISI marked, PVC short bend 32 mm dia including cost of seat cover complete in all respect and to the entire satisfaction of Engineer-in-charge. |
| 215 | Providing and fixing jet spray with 2\"-6\" long PVC pipe.With PTMT nut |
| 216 | Providing & Fixing in position C.P. Brass Hexa Nipple 15mm of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 217 | Providing and fixing in position vitreous Chinaware white lIndian make large flat back or angular lipped front urinal 375 x 390 x 590 mm of approved make (to the approval of the Engineer-in-charge) consisting of C.P. brass Urinal waste Coupling dome type 32mm outer length 75 mm , C.P. brass Urinal Spreader Ocular-Regular and C.P. brass tubeconnection 300 mm long complete. |
| 218 | Providing and fixing in position vitreous chinaware white lavatory suites of approved make (to the approval of Engineer-in-charge) consisting of C.P. brass waste 32mm dia with one C.P. brass pillar tap including Rack Bolt Screw Pair 115mm long complete in all respect. |
| 219 | Size 49 cm dia (above counter round) |
| 220 | Providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. |
| 221 | Providing and fixing in position stainless steel sinks of approved make (to the approval of Engineer-in-charge) 1mm thick,grade-304 (18/8) with waste coupling complete in all respect. |
| 222 | Rectangular Sink with Deluxe Border Single Bowl Overall Size 700 mm x 555 mm x 230 mm |
| 223 | Providing and fixingin positiontowel rails / ring of approved make (to the approval of Engineer-in-charge ) fixed in with rawl plugs embedded in walls with brass screws complete in all respect. |
| 224 | C.P. brass towel Rails size 15mm dia 610mm long |
| 225 | Providing & fixing in position PVC flexible tube connection of approved make (to the approval of Engineer-in-charge ) complete in all respect.PVC tube connection of size 15 mm x 375 mm with PTMT nut |
| 226 | Providing and fixing P.V.C Waste Pipe Collapsiable 32mm complete in all respect. |
| 227 | Providing and fixingin position C.P. brass soap dishof approved make (to the approval of Engineer-in-charge ) fixed into wall with rawl plugs and C.P brass screws complete in all respect. |
| 228 | Providing & Fixing in postion 15 mm i/d bib cock of approved make (to the approval of Engineer-in-charge )complete in all respect. |
| 229 | C.P. brass Bib cock long nose/ long body without flange |
| 230 | C.P Brass bib cock foam flow without flange |
| 231 | Providing & Fixing in postion stop cock / Angle valve of approved make (to the approval of Engineer-in-charge ) complete in all respect. |
| 232 | C.P.brass 15mm Angle valve without flange |
| 233 | C.P.brass 15mm Concealed stop cock with flange |
| 234 | Providing & Fixing in position C.P. Brass flange Dome of approved make (to the approval of Engineer-in-charge ) under various fixtures complete in all respect. |
| 235 | Providing & Fixing in position C.P. Brass extension piece 25mm long to 100mm long of approved make (to the approval of Engineer-incharge )with various fixtures complete in all respect.C.P. Brass extension piece, 25mm long to 50mm long |
| 236 | Providing & Fixing in position 5mm thick bevelled edge mirror of superior glass (of approved make) complete with 4mm thick hard board backingfixed in with rawl plugs 50mm, C.P. brass screws and washers and S/S Studs on topcomplete in all respect (as required by the Engineer-in- Charge) (Size 600mm x 450mm) |
| 237 | Providing and fixingin position C.P. brass overhead shower 1 flow with shower arm with 15mm i/d inletof approved make (to the approval of Engineer-in-charge) complete in all respect. |
| 238 | Providing & fixing in position 15 mm i/d C.P brass wall mixerof approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. brass wall mixer without telephonic shower |
| 239 | Providing and fixing in position premium range C.P. Brass Fittings and accessoriesof approved make (to the approval of Engineer-in-charge ) complete in all respect.C.P. Brass Accessories: |
| 240 | C.P. brass toilet roll holder with flap |
| 241 | Providing & Fixing in position C.P./Aluminium Khunti of approved make (to the approval of Engineer-in-charge ) fixed into wall with C.P. brass screws and rawl plugs etc. complete in all respect.C.P. Brass khunti with 3 pegs |
| 242 | Providing and fixing in position vitreous Chinaware white channel of approved make (to the approval of Engineer-in-charge) of size 600 mmx100mm including laying and fixing in cement concrete 1:2:4 complete in all respect. |
| 243 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Double Layer Tanks |
| 244 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod andPlastic Ball |
| 245 | Brass Ball Cock with rod andPlastic Ball 32mm i/d |
| 246 | Brass Ball Cock with rod andPlastic Ball 25mm i/d |
| 247 | Providing and fixing in position G.I. Tank Nipple of approved make (to the approval of Engineer-in-charge) in PVC Water storage tanks complete in all respect. |
| 248 | G.I. tank nipple 25mmi/d |
| 249 | Construction of Plateform complete as per specification& as desired by Enginer-in-charge |
| 250 | Sub Head-4 Flooring and Wall Tile |
| 251 | Base course of floor consisting of 100mm thick cement concrete 1:8:16 with stone aggregate 40mm guage and 100mm fine sand filling using mechanical mixer for mixing of material |
| 252 | Ground Floor |
| 253 | Screed of 50mm thick cement concrete 1:8:16 with stone aggregate 40mm gaugeto be laid below the topping using mechanical mixer for mixing of material |
| 254 | First Floor |
| 255 | Extra rate for First Floor |
| 256 | Providing and laying Rectified Porcelainfloor tiles 400x400mm or more (thickness to be specified by the manufacturer) of premium quality conforming to IS:15622 of approved make in all colours laid on 20mm thick bed of Cement Mortar 1:4 (1 Cement : 4 Fine sand) for new flooring complete |
| 257 | Ground Floor |
| 258 | First Floor |
| 259 | Extra Rate for First Floor |
| 260 | Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg /sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg/ sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry. |
| 261 | Providing and fixing 1st quality ceramic glazed wall tiles Matt/Semi Matt/Glosy/Highly Gloss finish/Highlighter/emboss conforming to IS : 15622 (thickness to be specified by the manufacture of approved make in all colours, shades except burgundy, bottle green, black of size 250 x 330 mm & 300x300mm as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:4 (1 cement: 4 fine sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 262 | Ground Floor |
| 263 | First Floor |
| 264 | Extra Rate for First Floor |
| 265 | Coloured Granite stone tiles 15mm to 20mm thick in skirting, risers of steps, dado walls and pillars laid in 12.5mm thick cement mortar 1:3 (1 cement 3 coarse sand) and jointed with neat cement slurry mixed with pigment to match the shade of stone, including rubbing and polishing including labour for fixing dowel pins and cramps.. |
| 266 | Ground Floor |
| 267 | First Floor |
| 268 | Extra Rate for First Floor |
| 269 | Extra labour for projected nosing of stair case of any shape and design |
| 270 | Sub Head -5 Water Coller & Air Conditioning |
| 271 | Providing & fixing in position Water Cooler without Stablizer of approved make (to the approval of Engineer-in-charge ) including carriage complete in all respect. |
| 272 | Water Cooler Semi Steel Body 80/120 ltr Capacity without Stablizer |
| 273 | Water Cooler Full Steel Body 40/80 ltr Capacity without Stablizer |
| 274 | Supply & Erection of automatic voltage stabilizer for storage type water cooler, Wall mounted, Heavy duty, copper wounded with volt meter etc. along with 3 core cord of suitable length and 3 pin power shoe including erection, connection & testing etc. complete in all respect as approved and desired by the Engineer-in-charge at site. Make... V – Guard or its equivalent. |
| 275 | Providing & fixing in position UV filter having flow rate 200 ltr/hr with 3 stage purification process having 16 watt UV lamp and 35 Watt power rating of approved make (to theapproval of Engineer-in-charge ) including carriage and fixing in position complete in all respect. |
| 276 | Providing & Installing & Erection split type wall mounted air conditioner capacity 1.5 tonne 5 Star Make:- Toshiba, Mitsubishi Electric, Daikin, O\" General, Hitachiwith 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipewithin building and installing charges complete in all respects |
| 277 | Providing & Installing & Erection split type wall mounted air conditioner capacity 2.0 tonne 5 Star Make:- Toshiba, Mitsubishi Electric, Daikin, O\" General, Hitachi with 4.00 KVA voltage stablizer, MCB arrangement for installing OD units on terrace including inlet and outlet copper tubes with proper insulation drainage arrangement cable link between ID unit and OD units stand for OD unit and connection of concealing of Copper pipes and drainage pipewithin building and installing charges complete in all respects |
| 278 | Providing laying hard soft copper concealing of copper pipes of dia 12.7mmod (insulation = 13mm)/9.5mm od (insulation = 13m) as per requirement and wall thickness 0.8mm, insulated, 4mm electric wire sheathed 3 core double insulated / taping laying in chase cutting of wall and repairing the same within the building and installing charges complete in all respects. |
| 279 | Providing, laying, jointing, fixing and testing ISI Marked uPVC Pipe with G.I. specials as per ISI-4985, including cost of G.I. specials such as tees, bends, sockets, elbows etc. testing inside building complete.uPVC Pipe 6 Kgf/cm240mm i/d |
| 280 | Sub Head-2 |
| 281 | Estate Water Supply |
| 282 | Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cuttingin streets or open areaincluding trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation,watering , including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. |
| 283 | EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge. |
| 284 | CPVC SDR 11 pipe & fittings 50mmo/d |
| 285 | Providing, fixing and jointing G.I Union Couplings(of approved make with the approval EIC) as per IS 1879in G.I. Pipe lines complete in all respect. |
| 286 | 50mm i/d G.I. Union |
| 287 | Providing ISI marked GM ferrule as per IS:2692 drilling and tapping cast iron pipe lines of all diametres and screwing in Ferrule and connections complete in all respect.25mm i/d Ferrule medium |
| 288 | Sub Work-3 |
| 289 | Sub Head-1 |
| 290 | Estate Sewerage |
| 291 | Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipes having ISI specification IS:15328-2003 class-SN-8 marked make Supreme, Finolex, Kissan, Jain, Prince or equivalent good on them and laying the same in trenches to correct alignment and gradients, cutting and jointing, testing for water tightness and making good the leakages and defects including cost of specials (Specials and Solvent should be of same make as that of pipes) complete in all respects. |
| 292 | 110 mm o/d pipes |
| 293 | 160 mm o/d pipes |
| 294 | Excavation in trenches with straight or open cutting in streets, lanes or in open area with 3D/JCB or excavator including manually dressing bed, trimming sides and side slopes for sewers and manholes to full depths as shown in drawings,including, dressing to correct sections and dewatering, provision for diversion for traffic, protection of existing services i.e. telephone cables, electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, watching, etc., fixing and maintenance of caution boards,fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoil from the site of works,upto one chain (15m) complete in all respects. |
| 295 | For depthexceeding 3.0 m but not exceeding 4.5 m B.G.L.For all classes of soil except rocky |
| 296 | Sand Fillling around UPVC Pipe |
| 297 | Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 80.00 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) insideplastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orangecoloured PVC steps including RCC cover with frame complete as per standard |
| 298 | Inside size75x120cm and 120 cm deep |
| 299 | Extra payable for every 0.30 m additional depth of manhole chamber in item 29.55 upto 1.80 m increase in depth of0.3mtr each |
| 300 | Sub Work-4 |
| 301 | Fire Fighting Equipment |
| 302 | Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect.4.5kg capacity |
| 303 | Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity |
| 304 | SITC of MS PipeProviding, laying, fixing, testing and commissioning of \"C\" Class heavy duty MS Pipe conforming to Indian Standard IS : 1239/3589 including fittings like tees, bends, sockets, elbows, flanges, tapers, nuts bolts, gaskets etc. fixing the pipe on the wall / ceiling with suitable clamps and painting with two or more coats of synthetic enamel paint of required shade complete in all respects. |
| 305 | 100mm internal diameter |
| 306 | SITC of Butterfly valveSupplying, Laying, Testing and Commissioning ofISI marked BUTTERFLY VALVE PN 1.6, with Gun metal seal duly ISI marked completewith rubber insertion, nuts, bolts and washers, matching flanges of required thickness, etc. complete as per specifications. |
| 307 | 100 mm i/d |
| 308 | Proving & fixing Dual plate check valve flanged end class PN-1.6 as per IS with nitrile seat SS shaft & springs in pipe lines includingjointing & cost of Nut Bolt , rubber insertion etc.complete. |
| 309 | 100mm i/d check valve |
| 310 | Providing and fixing S.S Pressure Gaugecomplete as required complete in all respect. |
| 311 | Dial diameter 100mm calibration 0-16 Kg |
| 312 | Providing and fixingfire brigade inlet connection of cast iron body with Gun metal63mm dia instantaneous type male coupling withbuilt in check valves and 150mm dia flanged outlet complete with bolts,nuts and rubber insertionsas per IS:904. (tobe connected to static tank). |
| 313 | Two Way inlet connection |
| 314 | Providing & placing in position on terrace (at all floor levels) HDPE water storage tanks of approved make (to the approval of Engineer -in-charge) with cover with suitable locking arrangement and making necessary holes for inlet, outlet and over flo pipes but without fittings and base support for tank. Triple Layer Tanks |
| 315 | Providing and fixing in position automatic brass Ball Cock in tanks.Brass Ball Cock with rod andPlastic Ball |
| 316 | Brass Ball Cock with rod andPlastic Ball 25mm i/d |
| 317 | Construction of Foundation for PVC water storage tank including RCC slab |
| 318 | For 10000 Ltr Capacity |
| 319 | Supplying, Installation, Testing and Commissioning ofRRL FIRE hose Type A, IS:636, 63mm dia x 15m long with gunmetal male & female couplings (ISI marked) bound & riveted to hose pipes with copper rivets and copper wire as required. |
| 320 | Supplying, Installation, Testing and Commissioning of First Aid-fire Hose reel with MS construction spray painted in post office red, confirming to IS 884 with upto date amendments, complete with rubber hose pipe (IS:444/1987) 20mm dia 30 meter long type-2, hose reel Drum with bracket as per IS:884,20mm dia GM nozzle and 20mm dia GM gate valve as required complete with G.I pipe connention with main pipe complete in all respect. |
| 321 | Providing & fixing Fire Hydrants with jointing including all carriages complete. (without Fire Hydrant surface box) Size 80mmcomplete in all respect.C.I Fire Hydrants 1S-908 |
| 322 | Supplying, Installation, Testing and Commissioning of weather proof cabinet for hose fabricated out of 1.6mm thickness M.S. sheet with front glass door having locking arrangement, suitable to accommodate all the necessary pipes, accessories, fittings etc including painting the metal portion with one coat of ready mixed primer paint and two coats of synthetic enamel paint of approved shade and quality, sign writing etc. |
| 323 | 900 mm wide x 600 mm high x 500 mm deep Size (for Yard Hydrant) |
| 324 | 600 mm wide x 600 mm high x 300 mm deep Size - (for RRL Reel) |
| 325 | Supplying, Installation, Testing and Commissioning63 mm dia gun-metal Branch Pipe (ISI marked) with 20mm (nominal internal dia) size Gun metal nozzleconfirming to IS 903, suitable for instantaneous connection to interconnect hose pipe coupling as required. |
| 326 | Supplying & fixing air vessel made out of 250mm. Dia, 8 mm thick MS sheet, 1200mm height with air release valves on top and flanged connection to risers, drain arrangements with 25 mm dia gunmetal wheel valves, with required accessories, pressure gauge and painting with synthetic enamel paint of approved shade as required |
| 327 | Providing and fixing of Pressure switch of approved makein MS pipe line suitable for line presure up 15kg/cm2 & including connection with main panel etc. as required complete in all respect |
| 328 | Supplying and Installation control valveC/W water motor gong complete with alarm Valve, constant trim, water motor bell, 2No. Pressure Gauge. All parts UL listed. Make Newagecomplete in all respect. |
| 329 | 100 mm control valve |
| 330 | Fabrication, Supply, Installing, testing and commissioning of cubical type fully enclosed panel switchgear connection, interconnection with AC strip flexible copper conductor MCCB, fully automatic star delta starter, etc complete required cable voltmeter. |
| 331 | Supply & erection of elctrically pumping machinery set (pump and motor) 3.50 kg/cm2t Make Crompton greaves confirming to ISI : 8034-2002 with latest amendments, with discharge of 450 LPM at head 35 mtr covered with rain shelter complete in all respect as per specifications. |
| 332 | XLPE/PVCINSULATED ARMOURED CABLES (ONSURFACE) Supply, laying of XLPE/PVC insulated PVC sheathed aluminium conductor un-armoured cable working voltage upto and including 1100 volts grade (on surface) as PWD General Specifications 2010: |
| 333 | (3 core) 16 Sq. mm |
| 334 | Electrical services |
| 335 | Providing Internal Electrical Installations |
| 336 | RECESSED PVC CONDUIT PIPE WIRING SYSTEM WITH MODULAR SWITCHES: Wiring in PVC insulated copper conductor single core FR cable (ISI marked) overall 1.5sq. mm, 1100volts grade to be laid in heavy gauge PVC conduit pipe 20mm/ 25mm dia. (ISI Marked) recessed in wall etc., complete with powder coated/anodized concealed metal boxes (1.6mm thick with Brass lugs) required for suitable number of modules (Modular accessories) for having Step type electronic fan regulators (two module) 100watts, bell push, 6Amp. 2/3 universal socket (shuttered), 16/20Amp. combined/ universal Socket (shuttered), 6/10Amp. Switches, 16/20Amp. switches with indicator etc. and covered with Frame Plate etc., PVC connector (For Fan Box and Call Bell), Steel Hooks, Sheet metal fan box (1.6mm thick shape hexagonal), Circular junction Boxes (Four way PVC 1½\" deep for walls and CI 3\" deep for ceiling), bonding to earth with PVC insulated copper conductor single core FR cable (ISI marked) 1sq. mm, 1100volts grade (For 6Amp. wall socket & plug control point) and other petty material etc., including the cost of above material, cutting and filling up of chases (withfinishing the surface):-Make :- PVC Pipe = Anchor, Polycab, Norpack, Adarh Plast, Diplast. PVC Copper Wires =Polycab, Tamra,KEI,Ecko, RR kabel, Rallison, Havell\"s, V-Guard, CMI, HPL.Accessories:-North-West(Nova), Havell\"s (Crab Tree), Legrand (Myrius), Hager |
| 337 | Wiring fan point with sheet metal fan box |
| 338 | Wiring light point |
| 339 | Wiring call-bell point |
| 340 | Wiring 3 pin 6 Amp. wall socket point |
| 341 | Wiring 3 Pin 6 Amp. Plug control comprising wall socket point |
| 342 | Wiring 3 pin 16/20 amp. power plug control point |
| 343 | Wiring light point with double control switches. |
| 344 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Make:-Polycab, Tamra,KEI,Ecko, RR kabel, Rallison, Havell\"s, V-Guard, CMI, HPL. |
| 345 | Overall size 1sq.mm (Un-sheathed) |
| 346 | Overall size 2.5sq.mm (Un-sheathed) |
| 347 | Overall size 4sq.mm (Un-sheathed) |
| 348 | Overall size 10sq.mm (Un-sheathed) |
| 349 | Overall size 16sq.mm (Un-sheathed) |
| 350 | Overall size 25sq.mm (Un-sheathed) |
| 351 | XLPE/ PVC INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-POLYCAB,RR KABEL,RALLISON,HAVELLS,. |
| 352 | Overall size 70sq.mm (3½ Core) Un-armoured (Loose) |
| 353 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Make:- Anchor, Polycab, Norpack, Adarh Plast, Diplast. |
| 354 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 355 | Heavy gauge PVC conduit pipe 40mm dia. (ISI marked) Flushed |
| 356 | Supply and erection of PVC flexible pipe complete without compression glands,locking arrangement, check-nuts as required:- |
| 357 | PVC flexible pipe 40mm dia. |
| 358 | Supply and erection of Compression glands, Locking arrangement, Checknuts for PVC flexible pipe complete with as required:- |
| 359 | PVC compression Socket gland 40mm dia. |
| 360 | HEAVY GUAGE WELDED CONDUIT PIPES:Supply & erection of Heavy guage welded conduit pipe (ISI marked) as per IS:9537:Part-II for wiring purposes including bends, junction boxes, Steel hooks, GI saddle clamps and other petty materials etc., where necessary including painting as per PWD General Specifications:- |
| 361 | Supply & erection of 19/20mm dia. M.S. conduit pipe (1.6mm thick), White painted suspension rod for ceiling fan. |
| 362 | COPPER EARTHING (Upto 14 metre in Length):-iii- Earthing with electrolytic Copper Tape rivetted (with 5Nos. copper rivets)/Steel Nut & bolts (with 4Nos. 32mm long, 8mm thick with washer and double nut) to 30cm x 120cm x 2mm thick copper plate (made cylindrical) burried 10.50 metre (34.44 feet) below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the Copper Tape recessed in wall and in floor etc., up to 14metre in Length (including bore Length). G.I. pipe 20mm dia. (A-class), 9metre long should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 363 | Earthing with 20mm x 3mm Copper Tape (upto 14Metre in Length) |
| 364 | Additional Length 20mm x 3mm thick Copper Tape . |
| 365 | SUPPLY AND ERECTION OF WIRING ACCESSORIES:Supply and erection of switches, sockets, power switch and sockets and other accessories (flush piano type/ modular accessories) in the existing bakelite/ modular cover frame including connections and petty material etc.Make :-Anchor / Fine |
| 366 | 6/10amp. One Way Modular Switch (One Module) |
| 367 | 6amp. 2/3 Universal Modular Shuttered Socket (two Module) |
| 368 | Modular Telephone Socket (RJ-11) One Module |
| 369 | Modular RJ-45 Modem Jack for Computer (One Module) |
| 370 | Supply and erection of Modular Cover Frame (Complete set) on the existing metal box including fixing and connection of existing switches and sockets and other petty material etc:- |
| 371 | Modular Cover Frame One or Two Module |
| 372 | Modular Cover Frame Six Module |
| 373 | Modular Cover Frame Eight Module |
| 374 | Supply and erection ofPVC Channel (uPVC Trunking) with cover of various sizes (On Surface) on wall, Flat angle, internal & external angle, Flat Tee, End cap and mounting boxes including the cost of joint cover, fixing and other petty material etc.:- |
| 375 | PVC Channel (uPVC Trunking) 100mm x 50mm |
| 376 | End Cap 100mm x 50mm |
| 377 | Mounting Box 1-3 Module |
| 378 | Mounting Box 4-5 Module |
| 379 | Mounting Box 8 Module |
| 380 | MINIATURE CIRCUIT BREAKERS:-Supply and erection of Miniature Circuit Breaker MCB\"s for circuit protection against overload and short circuitcurrent fault suitable for 240/ 415 volts 50cycles AC supply with breaking capacity of 10kA, Curve-C and low watt losses as per IS/IEC 60898-1, energy limitation class-3, true contact indication, label holder facility in the existing MCB distribution board as per PWD General Specifications including connections with suitable size of thimbles/lugs:- GROUP-A: Siemens (Beta Guard), Legrand (Lexic) , Schneider (Acti-9), L&T (Exora),Hager |
| 381 | MCB Single Pole 6-32amp. (10kA, Curve-C) |
| 382 | MCB Double Pole 6-32amp. (10kA, Curve-C) |
| 383 | MCB Four Pole 40amp. (10kA, Curve-C) |
| 384 | MCB Four Pole 50, 63amp. (10kA, Curve-C) |
| 385 | SHEET METAL DOUBLE DOOR DISTRIBUTION BOARD FOR MCB/ RCBO/ RCCB\"s:Supply and erection of sheet metal Double Door Distribution Boards IP 43- IK09 metal door (dust protected) as per IS 8623-1&3, IEC 61439-1&3 suitable for flush mounting with fully insulated copper busbars, shrouded neutral bars, earth bars, cement spill protector, colorcoded interconnecting wire set, cable ties, blanking plates and circuit identifications label and of required no. of ways for mounting miniature circuit breakers/ RCBO\"s/ RCCB\"s in the distribution board (For SP&N distribution board with provision DP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings and for TP&N horizontal distribution board with provision TPN/ FP MCB\"s/ RCCB\"s/ RCBO\"s as incomer and SP MCB\"s as outgoings) as per PWD General specifications including connections with suitable size of thimbles and bonding to existing earth etc:-Make:-Siemens (Beta Guard/Minigard), Legrand (Ekinoxe) ,Schneider (Acti-9), L&T (EXORA), HAGER |
| 386 | TP&N Horizontal Double Door Distribution Board 6 way each. |
| 387 | Supply and erection of sheet metal Cable End Box (Make is same as MCB Distribution Board) mounting on the top or bottom of the MCB Distribution Board (Either Horizontal or Vertical) to keep loose wires & cables as per PWD General specifications including petty materials etc as required:- |
| 388 | Cable End Box for TPN 6 Way |
| 389 | ON LOAD CHANGEOVER SWITCH (With Sheet Enclosure):-Supply and erection ofOn Load Change over Switch with advance neutral UNIT in sheet enclosure on the existing surface. (Confirms to IS 13947 (Part-3). complete with G.I. Bolts, Nuts etc. according to the size of holes in the body of the enclosure & Connections on both sides of switch with suitable size of thimbles as per PWD General Specifications:-Make:- HPL / L&T / C&S |
| 390 | On Load Change Over Switch Four Pole 100amp., 415volts (With Sheet Enclosure) |
| 391 | LT PANELS & MCCB\"s (MOULDED CASE CIRCUIT BREAKERS):-Designing, Supply, Erection, Testing & commissioning of indoor Type LT cubical panel enclosure (dust, vermin and interchangeable modules with facilites for extensions or reduction as per the space or requirments). The Panel shall be suitable for operation at 415+6% Volts, 50HZ, 3 phase 4 wire & earth system. The assembly manufacturer should be ISO approved and CPRI tested for short circuit of (minimum 50kA) as well as IP degree of protection (IP 54/55).Fabrication:- Panel shallbe made from 14/16 SWG CRCA sheet, conforming to IS 8623/1977-82. The sheet metal used for the fabrication of control panel will be 2mm for load bearing member’s door and fittings plates etc. the partitions and other non load bearing members will be fabricated out of 1.6mm sheet, the sheet will be of mild steel CRCA type. The base channel will be made out of 75 x 40 x 5mm rolled channel. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The panel door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. Minimum depth 400mm / wide 300 mm for busbar/ Cable ally at the front of the panel. The panel will be free standing floor mounting type having provision for cable entry from bottom/topwith cable glands etc. The fabrication should be such that all the member i.e. vertical/horizontal should be detachable type i.e. total bolted. In case of any changes required at site. it should be possible then and their self without any cutting or welding. The fabrication of the panel in 3B construction fully compartmentalized type i.e. bus bar chamber as well as the cable chamber should be totally isolated from the feeder chamber. Where there crossing of the wire or bus links. It should have proper rubber gourmets or non-hygroscopic material. No live part should be in visible condition.Painting:- The sheet metal is sprayed with corrosion resistant etch Primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work . |
| 392 | Busbars:-The panel shall be provided with TPN aluminium busbar of suitable size according to the size of MCCB\"s. Busbar shall be of high conductivity (53% to 58%) E91-E Grade aluminium (1A/Sq.mm). All Busbar will be airinsulated withcodified in Red,Yellow,Blue & Black asperstandardfor cable termination with the help of extended busbar only with proper adjustable cable supports. The main busbar would be supported upon non-hygroscopic SMC/DMC supports. Metering:-The panel shall be completed with digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB\"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB\"s) as per following:-digital metering unit (with selector switches, voltmeter & ammeter) epoxy insulator, gasket, PVC sleeves, CT\"s & L.E.D. type indicator etc. |
| 393 | Manufacturer of Panel should beCPRI Approved(Approval not older then 5 years) & ISO certified (Manufacturer workshop as per ISO 9001: 2015 standard) The Concerned contractor shall be approved the detailed drawing of panel with complete specification from the Engineer in charge at site.Detail of capacities of MCCB\"s to be installed in the cubical panel Enclosure (Excluding the cost of MCCB\"s) as per following:- |
| 394 | LT Panel enclosure having space for 1No. Incomer MCCB 160Amp. and 4Nos. outgoing MCCB\"s40amp. to 100amp. according to the requirement at site (Approx. size 1825 x 900 x 300mm) |
| 395 | LT Panel enclosure having space for 1No. Incomer MCCB 250Amp. and 6Nos. outgoing MCCB\"s40amp. to 125amp. according to the requirement at site (Approx. size 1300 x 1650 x 400mm) |
| 396 | MOULDED CASE CIRCUIT BREAKERS:Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubical type) in the existing Cubical Panel (confirm to IEC:60947-2) having Ics=100% Icu, 100% neutral with spreader terminal links, Extended rotary handle and relevantPWD general specifications complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with suitable size of thimbles etc Make: L&T, ABB (T-MAX), Schneider (CVS), Seimens(3VT1/3VL)):Hager,Legrand |
| 397 | MCCB Four Pole 40amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 398 | MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 399 | MCCB Four Pole 160amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 400 | MCCB Four Pole 200amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 401 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level includingexcavation placing the pipe in position and back filling with excavated soil etc. of the required size:-Make :-TeleRex,Gemni,CPE,Dura Line |
| 402 | Double walled corrugated (DWC) HDPE pipe120/103.5mm (outer/ inner dia.) |
| 403 | Supply and erection of LED batten 40watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make:- BAJAJCat No. BCLAB40W ,JAQUAR CAT NO. LGLZ01X040XC, PHILLIPS Cat no:-BN108C LED 40 S PSU CDL WH , CROMPTON:-LDL-40-CDL,C&S:-LTTB4F40WLED /W,HAVELLS:-STOUTPLUS1200BS40WLED840SPCWH |
| 404 | Supply and erection of LED batten 20watt LED (including LED driver) withHigh quality extruded aluminium with efficacy of LED fixture more than 100 lumens per wattand operating voltage between 140 to 270 volt, input AC frequency 50 Hz ± 1 % completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.LED Fitting as per Specifications approved by Hon. Tech. Advisor to CM Punjab vide Letter no ATPB/20/GL Dated 30/11/2017. Make: Jaquar LGLZ01X020XC / Philips BN02IC LED20S PSU CW GR/ Havells ENDURALINEARNEOBS20WLED830SPCWH,Crompton:-LDL-20-CDL, C&S:-LTTB4F20WLED/W |
| 405 | Supply and erection of Ceiling Fan 1200mm , 48\" with double ball bearing including flexible wire & petty material etc. for connections and testing . complete in all respects as appd. and desired by the Engineer in-charge at site. Makes:- Crompton Entrust 50- Opel White/ Havell\"s ES-50/ ANCHOR:-Panta Turbo Star code 13671WH / V-Guard Coolgate 48, Halonix:- Zephyr(ISI With ) |
| 406 | Supply and erection of Heavy duty Exhust Fans 300mm 900RPM with louver shutter, double ball bearinglonger life including flexible wire & petty material etc. for connections and testing completein all respect as approved and desired by the Engineer in-charges at site. Make:-Crompton EXHD300-6-1 /Havells Turbo Force SP / Anchor Anmol Heavy Duty . |
| 407 | Supply and fixing of triple compartment under floor trunking size 225mmx38mmmade out of 1.6mm thick pregalvanised sheetcomplete with all accessories and fixing accessories as per site requirement all as required & specified. Make:-LEGRAND /MK/ OBO |
| 408 | Supply and fixing of coupler/joint sleevfortriple compartment under floor trunking size 225mmx38mmwith all accessories and fixing accessories as per site requirement all as required & specified. Make:-LEGRAND /MK/ OBO |
| 409 | Supply and fixing of Junction Box 225*225mm with flyover fortriple compartment under floor trunking size 225mmx38mmwith all accessories and fixing accessories as per site requirement all as required & specified. Make:-LEGRAND /MK/ OBO |
| 410 | Supply and fixing of Pop-up type flush-mounting boxes (6modules) with matt aluminium finish, Soft opening cover with damper and push & slide locking system, all fixing accessories as per site requirement all as required & specified. Make:-LEGRAND /MK/ |
| 411 | Providing EPBAX System |
| 412 | Supply, Installation, Testing & Commissioning of the Switching system of the EPABX should be designed with IP at the core allowing fully distributed IP solutions across data networks in 19” Rack Mountable,7 universal slots in single Node and should support card Analog Extension Card , Digital Extension Card , for the respective addition / expansion. Analog & Digital extensions can be increased in the steps of 8, 16 & 32 Ports. Analog Trunks , PRI, BRI Trunks, E1 & SIP Trunks . Single card/module should support 2 or more PRIs, It should support 100% IP or 100 % TDM or a hybrid of IP/TDM technologies.1.2. The EPBAX configured for 04 trunk lines, 32 analogue extension card and 02 Sip Extension. The system should support IP Communication Devices (wired and wireless) e.g. IP Phones (Hard and Soft phones), Mobile IP Phones, multimedia PCs, SIP phones, Video phones (Hard & soft), etc.1.3. The system should also support Legacy TDM communication devices (Digital and analog 2 Wire telephone instruments with or without caller-id (Both FSK and DTMF), Fax, modems, ISDN phones etc. 1.6. The proposed system should support direct SIP integration with Microsoft Lync 2013 including following. Vendor should provide proper document towards certification with Microsoft Lync 2013 integration.1.16. The system should support at least 228 analog extensions in a single node and up to 600 analog Extensions in multiples nodes, at least 400 Digital Phones in a single node and 600 digital phones in multiple node, support at least 600 SIP extensions in a single node, Support 600 DECT/SIP DECT phones. support at least 224 DECT base stations and over 4000 SIP-DECT Base stations. should support minimum 56 Analog Trunks ,56 ISDN BRI trunks,14 PRI Trunks.Fax over IP with T.38 Interface and should support minimum 140 channels.240 SIP access channels.1.26. The system should have in-built Auto Attendant and Voice Mail system. complete in all respects as approved and desired by the Engineer in-charge at site. Make : Tadiran/ Aastra/ Nortel/ Ericsson/Mitel/Cisco |
| 413 | Supply and Erection ofIP base Operator-cum-maintenance console with Small Backlit Display, Direct Dialling Keys, Duplex Speaker Phone, Touch sense keysincluding all features listed in Product Boucher complete in all respect as desired by the engineer in charge at site. Make:Tadiran/ Aastra/Nortel/Ericsson/Mitel/Cisco |
| 414 | Supply & erection of Basic Phone with CLIP and display completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.Make: Beetel Model M51/C51/P-Tel/ Binatone/PANASONIC/Siemens. |
| 415 | Supply Installation Testing and commissioning of IP- SIP Featured Phones, with callers logs, redial lists, and 3 programmable keys, Transfer, Callers List, Hold, Redial, Goodbye, Options, 2 volume keys, Mute (with LED) and Speaker (with LED) as well as a 4-way navigation with Select/OK key, Hearing aid compatible (HAC) handset Full-duplex quality speakerphone Wideband handset and speaker phone codecs: G.711 µ-law / A-law, G.729, G.722, AMR*, AMR-WB(G.722.2)*, G.726, iLBC, BV16, BV32, L16 Echo cancellation, Comfort noise utilization, Packet loss concealment, Voice Quality Metrics, including MOS,Headset Mode support ,complete as per specification and as desired by EIC,PoE Class 1,Level\"\"V\"\" energy efficiency rated power adapters available,Dual 10/100 Mbps Ethernet portsCompatible with EPABX System Without Addition Programming completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Tadiran/Aastra/Nortel/Ericsson/Mitel. |
| 416 | Supply and erection 50 Pairs MDFwith Krone Modules & Lockable Box complete in all respect as desired by the engineer in charge at site. Make: Krone/M-Tel/Reliance/ A-Tel/Airtel |
| 417 | Supply & Erection of 10 PairMDF with Original Krone Modulelock & keyfacility completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Krone/M-Tel/Reliance/ A-Tel/Airtel |
| 418 | Supply & Erection of 20 PairMDF with Original Krone Modulelock & keyfacility completealong with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Krone/M-Tel/Reliance/ A-Tel/Airtel |
| 419 | Supply & erection of02 Pair 0.5mm PVC Dual sheathed Telephone Cable as per ITD Specification 113-B With Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton/ Finolex/ RR kabel/ POLYCAB/ HIMCOM/Shalimar. |
| 420 | Supply & erection of10 Pair 0.5mm PVC Dual sheathed Telephone Cable manufactured as per ITD Specification with Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton/ Finolex/ RR kabel/ POLYCAB/ Shalimar. |
| 421 | Supply & erection of20 Pair 0.5mm PVC Dual sheathed Telephone Cable manufactured as per ITD Specification with Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton/ Finolex/ RR kabel/ POLYCAB/ Shalimar. |
| 422 | Supply & erection of50 Pair 0.5mm PVC Dual sheathed Telephone Cable manufactured as per ITD Specification with Up to amendments complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site. Make: Delton/ Finolex/ RR kabel/ POLYCAB/ Shalimar. |
| 423 | Supply & erection of 1KVA Online LIT sine wave UPS/ Power Plant with in built SMF batteries having 30 Minutes backup time complete along with erection of the same with connections, testing etc. complete in all respects as approved and desired by the Engineer-in-charge at site.Make-APC/NUMERIC/ UNILINE/EATON/AQUA POWER. |
| 424 | PVC, HDPE PIPES & PVC FLEXIBLE PIPES:Supply & erection of PVC Conduit Pipes (ISI marked) as per IS9537:Part-III & HDPE pipes (ISI marked) as per IS:4984:1995 for wiring purposes including bends, junction boxes, Steel hooks, M.S. saddle clamps and other petty materials etc., as per PWD General Specifications:-Make:- Anchor, Polycab, Norpack, Adarh Plast, Diplast. |
| 425 | Heavy gauge PVC conduit pipe 25mm dia. (ISI marked) Flushed |
| 426 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level includingexcavation placing the pipe in position and back filling with excavated soil etc. of the required size:-Make :-TeleRex,Gemni,CPE,Dura Line |
| 427 | Double walled corrugated (DWC) HDPE pipe50/38mm (outer/ inner dia.) |
| 428 | Providing LIFT8 Passenger |
| 429 | Design, manufacture, supply, installation,testingandcommissioning of 8 passenger(Gear Less,without Machine Room) bedLift, with travel speed1.00 MPS serving different floors in the lift shaft, including lift well pressurization as per detailed specification/drawing enclosed and as under.Specifications: Type-8 Person/544 kgKgs Approximately ,Gear less without Machine Room,Speed-1.00 mps , Travel 4 Mtr. (approx) G + 1 Stops,2 Openings (all on the same side), Host way required: 2000mm W X 1900 mm D ,Car Size: min.1.31sq mtr and max.1.45 sq mtr, Car Entarance-Clear Opening: 800mm W X 2000mm H ,Central Opening doorsin SS Honey Comb/Hair Line Finish scratch resistance/vendal proof (40% area should be visible by glass), Pit Deptht-1600 mm below the finish floor level of first landing,Headroom - 5000mm,Simplex control sytem(V3F Microprocessor based Selective Collective Simplex Control with and without attentent ), Car-SS Honey Comb/Hair Line Finish scratch resistance/vendal proof,AutomaticDC Power Operateddoors with adjustable door opening and closing timings, Power Supply: 415 Volts, 3- phase, 50Hz Alternating Current ,Flooring -Granite Flooring Skid - Resistant as per standard,Automatic Rescue Device,InfraRed Screen Sensor,Over Load Warning Indicator with announcement,Full Load Bypass, Braille buttons, Hand Rail: Stainless Steel round Hand rail not less than 600mm long at 900mm above floor level (Side LH,Side RH & Rear) ,Stainless Steel Mirror Finish False ceiling in Car,Cross flow fans for ventillation in car,Dot Matrix Led D & P Indicators in Car & Landins - Orange colour, Push Button - Orange LED Illumination,3 way intercom - Press & Speak / Full Car operating panelplaced at a height between 800mm-1meter from the floor level,Back miror rear wall of half Car Height Floor Annunciator with music,Sill Angle,Sill Support,Fireman’s Switch,Battery Operated Alarm Bell and Emergency Light,Minor Builders Works,Scaffolding,Pit Ladder,Lift License,Free Service Two Years after the S/I/T/C Work and All other std Govt. features.Make:-OTIS/THYSSEN KRUPP/KONEE |
| 430 | XLPE INSULATED UN-ARMOURED CABLES (ON SURFACE):Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid (On Surface) as per PWD General Specifications:-Make :-POLYCAB,GEMSCAB,KEI,GRANDLAY, ECKO,ULTRACAB,UNIVERSAL\"s UNISTAR,RR KABEL,RALLISON,HAVELLS,RPG,BATRA HENLAY,CMI. |
| 431 | Overall size 16sq.mm (4Core) Un-armoured (On-Surface) |
| 432 | COPPER EARTHING :-(8 SWG COPPER EARTHING :):-Earthing with 8 SWG (4mm dia.) electrolytic copper wire thimbled (1No. copper thimble with suitable size steel bolt, washers & double nut) with 30cm x 60cm x 2mm thick copper plate (made cylindrical) burried below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper wire run through 20mm dia. G.I. pipe (A-Class) recessed in wall and in floor etc., up to suitable Length in metre (including bore Length). G.I. pipe 20mm dia. (A-class) of suitable Length should be laid in the hole of excavation 1 feet below ground level and having GI Reducer 50mm x 20mm with PVC Cap (For pouring water) fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of First class bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm (Heavy) around the hole of excavation:- |
| 433 | Earthing with 8 SWG (4mm dia.) copper wire thimbled with 30cm x 60cm x 2mm thick copper plate burried 10.50 metre (34.44 feet) below ground level (up to 14metre in Length) with G.I. pipe 20mm dia. (A-class), 9metre long |
| 434 | Additional Length copper wire 8 S.W.G. (4mm dia.) in 20mm dia. G.I. pipe (On Surface) |
| 435 | MOULDED CASE CIRCUIT BREAKERS:Supply and erection of Moulded Case Circuit Breaker (Panel mounting Cubicle type) in the existing Cubical Panel (conforms to IEC:60947-II) having Ics=100% Icu, 100% neutral with spreader links and relevant PWD General Specifications (Electrical Works) complete with G.I. Bolts, Nuts & Connection on both sides of MCCB with sutiable size of Thimbles etc.Make: L&T, ABB (T-MAX), Schneider (CVS), Seimens(3VT1/3VL)):Hager,Legrand |
| 436 | MCCB Four Pole 63/80/100amp., 415volts, =25kA Fixed Magnetic and Adjustable Thermal Setting |
| 437 | MS SHEET ENCLOSURE FOR MCCB\"s:Supply & Erection of indoor type MCCB enclosure of suitable size having provision for MCCB with extended rotary handle. The Enclosure shallbe made from 14/16 SWG CRCA sheet, confirming to IS 8623/1977-82. The door should be double folded without edge and the gasket should be ‘S’ type puffed neutral rubber gasket for long life. The hinges of the door should be bolted type with double hole arrangement. The Enclosure door lock should be quick openable type spring loaded. There should not be any special tool or key to open the lock. The Enclosure will be wall mounting type having provision for cable entry from bottom/topwith cable glands etc. The sheet metal is sprayed with corrosion resistant etch primer. The finishing treatment shall be applicable with air drying paint (7/9 tank Powder coated process should present in company pemises) after necessary putty work:- |
| 438 | MS Sheet Enclosure having provision for MCCB 40-160Amp.with extended rotary handle (Approx. Size 500mm x 300mm x 200mm) |
| 439 | Providing Diesel Generating Set 30 KVA |
| 440 | Supply, Erection, Testing and Commissioning of Silent (Sound Proof) Diesel Generator Set 30 KVA (3phase) .Itshould be air cooled/water coolednaturally aspirated/ turbo charged/ turbo charged after cool (As per manufacturer standard).ENGINE:The Diesel engine developing suitable BHP for giving a power rating as per ISO 8528- Part-1 ( With CPCB-II Norms) in KVA at the load terminals of alternator at 1500 rpm at actual site conditions. The engine shall confirm to IS 10000/ ISO 3046/ BS: 649/ BS 5514 amended up to date have dynamically balanced Fly wheel, air cleaner (dry/ oil bath type) as per manufacturer standard. A mechanical/ electronic governor of TYPE A1 AND A2 to maintain engine speed at all conditions of load, daily fuel service tank of minimum 8 hours running capacity as per manufacturer standard, Dry exhaust manifold with suitable exhaust residential grade silencer to reduce the noise level.suitable self-starter for 12 V/ 24 V DC ,battery charging alternator unit and voltage regulator, Lubrication oil cooler,Lubrication oil filters with replaceable elements.ENGINE CONTROL PANEL: Engine control panel fitted and having digital display i.e Start/stop key switch/push button, Battery charging indication,Engine Hours indications, Over speed indication, High water temperature indication, Lubricant oil pressure indication,) RPM indication and MCCB (Fixed Thermal and Adjustable Thermal protection) of suitable rating for outgoing supply. ALTERNATOR: The alternator should be designed as per (IS4722 and IEC:34 ) standard. Rated Power Factor : 0.8 (lag), Rated voltage : 230/415 volt, SPDP (Screen Protected Drip Proof), Degree of protection: IP-23, Ventilation : Self ventilated air cooled Alternator should have 40 degree maximum class H insulation, Automatic voltage regulator unit should be provided as per standard practice of manufacturer. Its voltage dip shall not exceed more than 20% of the rated voltage at any step load or transient load as per ISO 8528 (Part-1). Its efficiency at full load 0.8 power factor, 10% overload one hour in every 12 hrs of continuous use.ACOUSTIC ENCLOSURE: The enclosure shall be fabricated out the CRCA sheet of thickness not less than 1.6 mm on the outside cover with inside cover having not less than 0.6 mm thick perforated powder coated CRCA sheet. It should be IP54 Suitable for outdoor installation exposed to weather conditions, noise level up to 75 dB (A). All sheet metal parts should be processed through 7-tank pre treatment process and batteriesaccommodated in thebattery rack .The acoustic lining should be made up of high quality insulation material i.e. Rockwool / glass/ mineral wool / PU foam of appropriate thickness & density for sound absorption.The inside of enclosure should be provided with at least one no. 28 W-T5 fluorescent tube light/ LED 10Watt luminaries controlled by a 5A switch for adequate lighting during servicing etc. complete in all respect as desired by engineer at site:-The Generator set should be instaaled at site on the suitable sizeexistingplinth of RCC as per specifacationDG set as per satisfacation of the Engineer- in-Charge at site. The model of engine will be decided by the Engineer in Charge..Make-CUMMINS/KOEL GREEN/MAHINDRA |
| 441 | XLPE/ PVC INSULATED UN-ARMOURED CABLES (LOOSE):Supply & laying of aluminium conductor XLPE/ P.V.C. insulated un-armoured and served cable to be laid loose in the existing trench or pipe as per PWD General Specidications 2010:-Make :- POLYCAB, ECKO,ULTRACAB,\RR KABEL,RALLISON,HAVELLS,\ |
| 442 | XLPE/ PVC insulated PVC sheathed aluminium conductor unarmoured cable working voltage 1100volts grade 35sq.mm (3 ½ Core) |
| 443 | COPPER EARTHING: |
| 444 | Earthing of Sheetmetal/ iron clad switches andmetallic cases etc., with 20 mm x 3 mm thick electrolytic copper tape rivetted (with 10 nos. copper rivets) to 30 cm x 120 cm x 3 mm thick tinned copper plate (made cylindrical) burried 10 metre below ground level in the hole of excavation having bore dia. 125mm and surrounded by salt & charcoal dust mixture (20 kg.) including fixing the copper tape on wall and in floor etc.,up to 13 metre in length (including bore length). G.I. pipe 20mm dia. (A-class) should be laid in the hole of excavation from bore surface level to 1 feet below ground level and having wire mesh funnel fixed on the top level of the pipe. 300mm x 300mm x 300mm deep haudi of bricks finished with 1:4 cement plaster and haudi covered with cast iron lid having size 300mm x 300mm around the hole of excavation. |
| 445 | Supply and Erection of 20mm x 3mm thick copper tape (As additional length). |
| 446 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES:Supply and erection of double walled corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation (making necessary trench), placing the pipe in position and back filling with excavated soil etc. of the required size. Make :-TeleRex,Gemni,CPE,Dura Line |
| 447 | Double walled corrugated (DWC) HDPE pipe 90/76 mm (outer/ inner dia.) |
| 448 | Providing Campus Lighting |
| 449 | 3-STEPPED STEEL TUBULAR POLE:Supply and erection of 3-Stepped steel tubular swaged and welded pole (410-SPMpa) of suitable length confirming to IS: 2713- (PART-II)-1980 (Steel tubes confirming to IS: 1161-1979, UTS 42 kgf/ Sq.mm) to fix up to a required planting depth below ground level in a hole of excavation about 45 cm dia. and suitable depth to fill up to 15 cm below G/L with 1:2:4 cement concrete mixture including painting of pole with two coats of approved aluminium paint as required:- |
| 450 | Overall length 7 metre, with planting depth 1.25 metre, length of sections 4 metre, 1.5 metre and 1.5 metre (Bottom, Middle and Top respectively), Outer dia and thickness of sections 114.3mm x 4.5mm, 88.9mm x 4.05mm and 76.1mm x 3.25mm (Bottom, Middle and Top respectively) with approximate weight 73 kg. (410 SP-2) and base Plate weight 7.5 kg. of size 12mm thick about 30 cm dia. |
| 451 | SINGLE/ DOUBLE/ TRIPLE/ FOUR/ SIX ARMS BRACKET FOR STEEL TUBULAR POLE:Supply and erection of G.I. Pipe 50mm dia. (Medium) Single/ Double/ Triple arm bracket of suitable length welded with MS canopy 80mm inner dia., outer dia 89.5mm (Medium), 450mm long suitable for 3 stepped steel tubular swaged and welded pole with top outer section dia. 76.1mm. The MS canopy should have 3no. holes for fixing the bracket at the top end of the pole with the help of 3Nos. ½\" x 1½\" size nut bolt fully threaded. The bracket should have MS sheet (1.62mm thick) ring of 89.5mm dia. for covering the top end of the canopy. The MS canopy and GI bracket should be welded at tentative angle 105º (105 degree) inclination with MS sheet 5mm thicktriangular in shape having dimensions 225/300/375mm x 150mm x 5mm thick (225mm for 1.5m, 300mm for 2m & 375mm for 2.5m long bracket) with two coats of an approved aluminium paint as desired by Engineer-in-charge at site:- |
| 452 | Single Arm Bracket 1 metre Long for Steel Tubular Pole (7 to 8m) |
| 453 | CEMENT CONCRETE MUFFS:-Making of Cement Concrete muff of suitable size and length with 1:2:4 cement concrete mixture. The muff is to be made around the steel tubular pole sufficient to completely flush a SMC Junction Box (Glass Fibre reinforced polyester sheet moulding compound) confirming to IS:14772, inner dimensions 250mm x 200mm x 100mm with ± 10% tolerance in size & hinged water tight cover with locking arrangement having 1No. terminal strip with 4Nos. terminals & 1No. Single pole MCB of required capacity fixed on din bar (Din Bar Provision for 2Nos. MCB\"s). The SMC junction box is to be fixed with the pole by a MS flat clamp of size 20mm x 2mm thick. PVC pipe 40mm dia. (2No.x0.60m) should be provided for incoming and outgoing cables. The outer surface of the muff shall be finished with pure cement & two coats of white snowcem complete in all respectas approved and desired by the Engineer In-Charge at site:- |
| 454 | Cement Concrete Muff of Overall Size 450mm dia., 80cm Long |
| 455 | Supply and erection of LED Street Light 45 watt with pressure die cast aluminium housing with control gear ( with IP 65/ IP 66 protection), toughened glass fitting, surge protection 10KV and efficacy of LED fixture minimum 100 lumens per watt complete in all respects as approved and desired by the Engineer in-charge at site .LED Fitting as per circular issued by Hon. Tech. Advisor to CM Punjab Letter no ATPB/20/GL Dated 30/11/2017Make:- HavellENDURAPEARLNEOSL45WLED757SASYTOPC / Wipro LR02-501-XXX-57-GI /Jaquar LSRT01S045XC /CROMPTON LSTP-45-CDL. |
| 456 | XLPE/ PVC INSULATED UN-ARMOURED CABLES (LOOSE):-Supply, laying and erection of aluminium conductor XLPE insulated PVC sheathed Un-armoured and served cable 1100 volts grade as per IS 7098 (Part-1)1988 to be laid loose in the existing trench or pipe as per PWD General Specifications:-Make:-Make:-Bonton,Polycab,Gemscab, KEI, Grandlay, Ultracab, RR kabel, Havell\"s. |
| 457 | Overall size 6sq.mm (4Core) Un-armoured (Loose) |
| 458 | DOUBLE WALLED CORRUGATED (DWC) HDPE PIPES: Supply and erection of Double Walled Corrugated (DWC) HDPE pipe to be laid 1mtr. below ground level including excavation placing the pipe in position and back filling with excavated soil etc. of the required size:- Make :- TeleRex,Gemni,CPE,Dura Line |
| 459 | Double walled corrugated (DWC) HDPE pipe50/38mm (outer/ inner dia.) |
| 460 | GALVANIZED IRON PIPES AND G.I. EARTHING:Earthing with G.I. wire/ rope in G.I. pipe partly recessed and partly on surface complete with 150cm long 50mm dia. G.I. earth pipe (Cutting threads and 36 Nos. holes, 1cm dia. to make a mesh around the GI Pipe) with G.I. reducing socket including erection of the same, 4.50 metre (14.76 feet) below ground level with 20Kg. charcoal & salt mixture etc., up to 8 metre in length (including boring & refilling). |
| 461 | Earthing with 8 S.W.G. (4mm dia.) G.I. wire in 15mm dia G.I. pipe with G.I. reducing socket 50mm x 15mm (upto 8Metre in length) |
| 462 | Additional length G.I. wire 8 S.W.G. (4mm dia.) in 15mm dia. G.I. pipe (On Surface) |
| 463 | Earthing earth rod 20 mm dia for providing earth connections upto line earth with G.I. Wire 8 S.W.G. (4mm dia.). The rod shall be tapered at one end and flatted on other end. The hole size 10mm dia shall be drilled on the flatened side for facilitating connection with G.I. wire and thimble etc. The rod shall be erected in ground upto complete length vertically:- |
| 464 | GI Earth rod 20 mm dia. 3 mtr. Long |
| 465 | PVC INSULATED SINGLE CORE FR COPPER CONDUCTOR CABLE:Supply and erection of PVC insulated FR single core Unsheathed copper conductor cable (ISI marked) suitable upto 1100 volts grade confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:-Make:-Bonton,Polycab, Tamra, Gemscab, KEI, Grandlay, Ecko, Ultracab, RR kabel, Rallison, Havell\"s, L&T, Batra Henlay, V-Guard, CMI, Great White Securex,HPL, Goldmedal.. |
| 466 | Overall size 1.5sq.mm (Un-sheathed) |
| 467 | SHEET METAL CUBICAL PEDESTAL, TOWER STRUCTURES, HT & LT LINE ITEMS, MS CHANNELS, BRASS GLANDS, ALUMINIUM & COPPER THIMBLES:-CUBICAL PEDESTAL:-Supply and erection of Sheet metal cubical pedestal made from 50mmx50mmx6mm thick MS angle iron frame with 5 sides welded & covered with MS sheet 2mm thick & front side hinged with 4\" hinges & locking system with single/ double door openable placed on MS strip of size 12.5mm x 2.5mm thick welded with MS sheet, 4Nos. legs of 50mmx50mmx6mm thick MS angle iron each of 600mm long with MS sheet 100mmx100mmx6mm thick at the bottom end of the legs. Front door welded x-sectionally with MS flat 25mmx5mm. The front side with MS sheet each 75mm wide & a bend of 75mm width outwards & inwards on all sides with tappered top 200mm high and pedestal with 4 Nos. supporting members each of MS flat 50mmx6mm thick according to cubical size duly welded & complete pedestal to be painted with 1 coat of red oxide & 2 coats of paint & bonding to the existing earth. The Pedestal platform should befilled with 1:2:4 cement concrete mixtureand erected 150mm high from the top of the cement concrete platform. The job is to be completed as approved by Engineer-in-charge:- |
| 468 | Cubical Size 900mm high, 600mm wide and 350mm deep |
| 469 | SWITCH DISCONNECTOR FUSE UNIT (With Sheet Enclosure):- Supply and erection of Switch Disconnector Fuse Unit with HRC Fuses (Suitable for DIN HRC Fuses) in sheet enclosure on the existing surface Confirms to IS 13947 (Part-III), IEC 60947-3 complete with G.I. Bolts, Nuts & Connections on both sides of switch with suitable size of thimbles, including cost of DIN HRC fuses as per PWD General Specifications:- |
| 470 | SDF TP&N 32Amp., 415volts (With Sheet Enclosure) |
| 471 | Solar Power Generation System |
| 472 | Supply, Installtion testing & commissioning of Grid Interactive PV System Solar Power Plant (i.e connected to utility grid) of Minimum 20KWp including required quantities of SPV modules (Hight Power density Perc Bifacial Mococrytalline based) formed in to arrays, their mounting arrangement, Power conditioning units (i.e string Solar Inverter), required DC & AC distribution panels with surge protection units, cabling from terrace to main distribution board throughcable tray Bi Directional Energy Meter required Earthing (i.e2 Nos GI strip earthing for GI Strcuture, 2 Nos GI Strip earthing for string inverter, AC & DC Distribution system) ESE stroke master (As per NFC 17 102 standard with suitable radius of protection) & 3 Nos chemical earthing with copper bonded rods along with high rise GPSP structure (Rated wind speed 170Kph) including mounting height up to 8 feet complete with transportaion, fabrication labour & civil work.Features :- 1. Solar PV Module warranty 25 Years & certified under IS/IEC 61730 I & II IS/IEC 61701 & IS/EC 142862. Power Conditioning unit (string solar inverter) & certified under IEC/EN 62109-1, IEC/EN 62109-2, EN 61000-6-2, EN 61000-6-3, IEC 61683, EN 50530, IEC 60068-2-1, 2, 14, 30, EN 605293. Structure 25 Years service life with AMC & certified under IS 2062 20114. Complete Plant insurance for the period of 5 Years (Excluding Theft of the Material)5. Annual Maintenance contract for the period of 5 YearsMake :-1 Solar PV Module = EMBRO, VIKRAM, ADANI, WAREE2 Power Conditioning Unit = KEHUA, DELTA, LUMINOUS, SOLAX, TESA3 AC/DC Distribution Board = EMBRO, ABB, SCHNEIDER ELECTRIC, HAVELL\"S4 Fusion Mount structure = TATA GALVUME, POSMAC5 ESE Stroemaster with chemical Earthing = SABO, JMC, TP, HIGH GRIDThe work will got done from approved MNRE (Misitry of New and Renewable Energy)/ PEDA (Punjab Energy Development Agency) contractorThe Rate are inclusive of all taxes including GST |
| 473 | Cost of Civil works |
| 474 | Cost of Public Health Services |
| 475 | Cost of Electrical Services |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy