Name of Work: PROVN OF PGI SHEET IN LIEU OF AC SHEETS IN NAGROTA MIL STATION
Sl. No. Item Description
1Dismantling of asbestos cement (corrugated, semi corrugated etc) sheets in roof coverings
2Material and Labour for Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.
3Supply and fixingPre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile satrength of 550Mpa as in roof ridge, fixed with self tapping screws as specified.
4Dismantling timber scantlings 40 sq. cm and over in section, in any positionas framed work
5Dismantling timber scantlings of fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section framed work all as specified.
6Dismantling of wrought iron and mild steel work of anydiscription not otherwise provided for all as specified.
7Supply and fixing trusses (framed),trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel, gusset plates, or flat sections)including distance pieces, cleats etc Fe 410-W (GdeE. 250) quality - A complete all as specified.
8Supply and fixing steel screw bolt ( machine made) dia 16 to 20mm with hexagonal or square heads at one end and screwed the other , or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, but length of bolt exc 22.5cm and n exc 30cm long complete all as specified.
9Demolation of brick work built in cement mortar or cement lime mortar incl all quoins, arches pillars etc and removing unserviceable material exc 100 mtr as specified.
10Material and Labour for brick work with subclass "B" well burnt bricks, straight or curved on plan exc 6mmean radius built in CM 1.:6 complete all as specified.
11All as per srlitem No 10 here - in - before specified but except bricks.
12dismantling wall & ceiling boards (fibre,pulp,insulation, etc) or insulation boards/ slabs/blankets, any thickness including cover fillets complete all as specified and as directed.
13Supply and fixing aluminium anodized snap grid (powder coated) frame work of grid size 605x605mm including hangers 6mm dia GI (upto 1200mm long) for false ceiling including notching and prepaing holes, including aluminium cleat/corner pieces and GI 4mm dia suspenderswith utterfly clips, wall angles of size 24x24mm, main runner (teee) of size 24x38mm, cross tee of size 24x28mm, (No of suspenders shall be decided by the GE as per actual size requirement ) including 4mm thick non asbestos fibre cement plain buildings boards fixed to aluminium snap grid and providing two coats of white wash including preparation of surfaces all as specified and directed.
14Applying two coats of synthtic enemal paint over a coat of red oxide zinc chrome primer on new steel surfaces any description, not otherwise described over 10cm width or girth including preparation of surfaces.
15Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubing down with water etc.
16Material and Labourfor 15mm thick rendering on brick work or concrete surface in CM 1:4and finish the surface even and smooth with out using extra cement.
17Material and Labour for rendering 15mm thick in CM 1:6 on other than fair face of brick work/ stone wall surfaces finished even and smooth with out using extra cement all as specified.
18Preparing new decorated surfaces of external walls and applying two coats of cement base paint over a coat of primer complete as specified and directed.
19Preparing new plastered surfaces of wall and applying two coats of oil bound distemper over 1 to 2 mm thickwall care putty over a coat primer on walls etc all as specified.
20Material and Labour for mild steel section as Wind tie, drilled and counttersunk for roof including securing bolts Fe-290 Gde 165 complete all as specified and directed.
21Merial and Labour for PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in benching coping etc and similar items including weathering slightly rounded or chamfered angles and throating on top of chajjas rails cills, bed blocks etc. including necessary form work.
22Material and Labour for applying one coat of synthetic enamel paint on old painted steel surfaces of any description having width/girth exceeding 10 cm including preparation and rubbing with sand paper to make surface even and smooth and apply putty and primer where required complete all as specified.
23Material and Labour for preparation of old decorated plastered /concrete/brick surfaces of walls (up to 3rd storey with necesasary scaffolding) and applying one coat of cement based paint on old decorated surfaces.
24Material and Labour for preparation of old decorated brick/concrete plastered surfaces of walls, Pillars, cornices, etc by booming down with steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots and applying one coat of lime white wash on the walls, pillars, cornices etc. complete all as specified and directed.
25Material and labour for preparation of new steel or iron surfaces and applying two coats of Synthetic enamel paint over a coat of red oxide on steel or iron Surfaces of any description , n.exc 10cm in width or girth when unconnected with other painting or when painted in a different tint.
26Material and labour for preparation of old decorated plastered /concrete /brick surfaces of walls (up to 3rd storey with necessary scaffolding) and applying one coat of white wash.
27Material and labour for preparation of new decorated surfaces of external walls and applying two coat of Wheather coat exterior emulsion over a coat of primer complete all as specified and direceted
28Preparingnew plastered surfaces ofwall and applying two coats of interior emulsion paint over 1 to 2 mm thick wall care putty over a coat of primer on walls etc all as specified.
29Taking downcopper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fitting such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc. removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions seperately) and making good disturbes surfaces of walls, floors, etc.
30Taking down carefully ceiling /exhaust fan any sweep any size, removing blades, cleaning the fan completely for dust and dirt, greasing, oiling, painting of ceiling/exhaust fans complete, in situ with synthetic enamel paint by spraying including filling cavaties with filler, one coat after cleaning all dust etc. and hanging /fixingthe same back to its original positions including connecting with three core fixible copper wire to ceiling rose etc all as specified and directed by Engr-in-Charge.
31Taking down carefully water heater any size/any make, cleaning the water heater completely for dust anddirt and re-fixing the same back to its original positions after the completion of the point wiring all as specified and directed by Engr-in-Charge.
32Taking down existing light fittings any type any size and refixing the same incl connection and testing complete and making good disturbed surfaces of walls, ceiling etc complete all as specified and directed by Engineer-in- Charge to match with existing surface.
33Material and Labour for point wiringSP one way complete with 1.5 sq mm (normal area) PVC insulated, unsheathed and multi strand copper conductor FRLS cable (ISI marked) drawn into and including PVC concealed conduit (medium quality) and conduit fittings including 1.5 Sq mm PVC insulated unsheathed and multi standed copper conductor FRLS cable as earth wire to common earth and connecting to earth dolly etc complete all as specified and directed for one light point /bell point controlled by one one way switch 5Amp.
34Ditto -all as per item No-33 above but for one ceiling fan/exhaust fan point.
35Ditto -all as per item No-33 above but for one 3 pin 5 Amp socket on same board all as directed
36Ditto -all as per item No-33 here-in- before but for one 3 pin 5 Amp socket on indipendant board all as directed
37Ditto -all as per item No-33 here-in-beforebut with 4 sqmm copper conductor FRLS cable for 15 Amp socket with 4 sqmm earth continuity conductor FRLS cable.
38Supply and fixing Modular snap switch SP one way 5/6 Amps suitable for 1 Module complete all as specified.
39upply and fixing Modular bell push one way 5/6 Amps suitable for 1 module complete all as specified.
40Supply and fixing Modular socket 5 pin 5/6 Amps suitable for 2 Module complete all as specified.
41Supply and fixing Modular snap switch SP one way 15/16 Amps suitable for 1 Module complete all as specified.
42Supply and fixing Modular socket 5/6 pin 15/16 Amps suitable for 2 Module complete all as specified.
43Supply and fixing Modular fan step Regulator electronic, 120 watts 2 Module complete all as specified.
44Supply and fixing Modular white cover plate incl Modular base frame & powder coated Modular sheet metal concealed box for 6 module complete all as specified.
45All as per Item No-44 above but 3 module complete all as specified.
46All as per Item No-44 above but 2 module complete all as specified.
47All as per Item No-44 above but 8 module complete all as specified.
48All as per Item No-44 above but 12 module complete all as specified.
49Supply and fixing blanking plates 1 module complete all as specified.
50Supply and fixing ceiling rose surface backalite 65 x 50 mm, two to three terminals complete all as specified.
51Material and labourfor taking out and refixing serviceable lamp holder insulated body with back plate in the same location after complete B/R repair work and making good to the disturbed surfaces complete all as specified.
52Supply and fixing integral sleek extruded batten aluminium/CRCA channel fitting with polycarbonate LED tube rod 18 watt with acrylic cover and end caps complete with all accessories including connecting up with three core twisted flexible copper conductor cable ofsuitable size of 230V, 50Hz , 1800 lumens, colour temp 6000K, IP 20 and 5KV surge protection complete all as speified and directed by Engineer - in - charge.
53supply and fixing LED 9W-B22 CDL ball lamp, all as specified.
54supply and fixing LED luminire 600mmx600mm, 35/36W, 220V AC recessesd type with high efficiency PMMA difuser soft glair free light complete with driver, holder and LED lamp suitable for roof ceiling up with driver three core flexible copper conductor cable of suitable type complete all as specified and directed by Engineer-in-Charge.
55supply and fixing LED street /security light fittings 35 watt 230V AC outdoor type with high pressure dia cast aluminium hosing and heat resistant with driver, lamps, bracket with impact and corrosion resistant incl thermal management in multioptics complete with IP 65/66 protection complete for the bldgs /stores /sheds complete with all accessories including connecting up with driver three core flexible copper conductor cable of suitable size of 230V, 50 Hz, 3500 lumens complete all as specified and directed by Engineer-in-Charge.
56supply and fixing, in replscement of DB sheet metal enclosure double door for MCBs, company made, SPN 240 Volts 12 ways with IP 42 protection complete incl taking down existing unserviceable DB with MCB"s all as specified and directed by Engineer -in -Charge.
57supply and fixing, in replacement of DB sheet metal enclosure double door for MCBs, company made, SPN 240V Volts 8 ways with IP 42 protection complete incl taking down existing unserviceable DB with MCB"s all as specified and directed by Engineer -in -Charge.
58supply and fixing, in replacement of DB sheet metal enclosure double door for MCBs, company made, SPN 240 Volts 4 ways with IP 42 protection complete incl taking down existing unserviceable DB with MCB"s all as specified and directed by Engineer-in-Charge.
59supply and fixing, DB sheet metal enclouser double door/for MCBs, company made, TPN 415 Volts 4 way with busbar and incomer MCCB 100 Amp complete incl taking down existing unserviceable DB with MCB,s, all as specified and directed .
60supply and fixing, in replacement of MCB TP 415 Volts 32 Amps to 63 Amp complete all as specified and directed by Engineer-in-Charge.
61supply and fixing, in replacement of MCB SPN 240 Volts 32 Amps complete all as specified and directed by Engineer-in-Charge.
62supply and fixing, in replacement of MCBSPN 240 Volts 63 Amps complete all as specified and directed by Engineer-in-Charge.
63supply and fixing, in replacement of MCB SP 240 Volts 5 Amps to 32 Amp complete all as specified and directed by Engineer-in-Charge.
64supply and fixing, in replacement of MCB SP 240 Volts 63 Amps complete all as specified and directed by Engineer-in-Charge.
65supply and fixing sub main wiring with PVC insulated, FRLS cable 2 single core 6 Sq mm 1100 V grade with stranded copper conductor on and incl PVC rigid non metalic conduit (ISI marked) in concealed incl all specials like joint, elbow, Tee, junction, bend etc and provision of PVC insulated copper conductor single core 6 sq mm for earth continuity conductor complete all as directed by engineer - in - charge.
66Material and labour , earthing complete with galvanize steel earth plate electrode 60cms x 60cms x 6.00mm thick buried directly inground vertically to a depth not less than 2.25meter below ground level with top edge of the plate not less than 1.5 meter below normal ground level connected to galvanised earth lead wire 4.0mm by means of bolts, nuts ,check nuts and washers of galvanized iron or steel and thimbles and other end of the earth wire connected to main switch board and protected by wire mesh, including all necessary excavation and earth work PCC chamber in cement concrete 1:3:6 type C-2 and RCC cover and all as shown in electric plate No, 5 of MES Sch PArt-1 (2009), completer all as specified.
67Deduction to be made from BOQfor Sch "A" Part - II (Schedule of credit) Amont of Rs. 1605701.50.00 during AOC. Note: Tenderers shall not quote for this schedule.