|
| 1 | Demolition of plain cement concrete in ground floor and pavings not exc 15 cm thick (below or above ground level) including floor tiles of any description complete all as specified and as directed. |
| 2 | Dismantling floor, hearth or wall tiling including cement mortar bedding (including backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. |
| 3 | Demolition of brick work or stone/boulder masonry built in cement mortar, complete all as specified and as directed |
| 4 | M&L for Pre-cast cement concrete type C5 (1:3:6) block masonry with solid blocks, exc. 10 cm in width and setting in mortar (1:4) complete all as specified and as directed. |
| 5 | Taking down cement plaster of any description built in cement mortar on brick or stone walls etc including racking out joints, hacking for Key, scrubbing down with water etc. complete all as specified and as directed. |
| 6 | M&L for 15 mm thick rendering on brick work in cement mortar (1:6) and finished the surfaces even and smooth without using extra cement complete all as specified and as directed. |
| 7 | M&L for preparation of new plastered surface & applying two coats of oil bound distemper (OBD) over a coat of white chalk on wall complete all as specified and as directed. |
| 8 | M&L 40mm thick Cement concrete type B-1, 1:2:4 (20mm graded Sqm 119 aggregate) as in sub base rough finished complete all as specified and as directed. |
| 9 | M&L for coloured nonskid ceramic tiles 7 to 8mm thick Sqm 119 (square/rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including 15mm thick screed bed of CM 1:6, complete all as specified and as directed. |
| 10 | All as per above item herein before but in skirting including necessary cutting of tiles and backing laying 10mm thick CM 1:3 on vertical surfaces/backing coat complete all as specified and as directed. |
| 11 | Material and labour for non skid ceramic coloured tiles 7 to 8mm Sqm 28 thick (Square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm coloured in floor etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 15mm thick screed bed in CM (1:6) complete all as specified and as directed. |
| 12 | M&L for glazed ceramic coloured tiles of size 450X 350X 7mm thick as on vertical surfaces, set and jointed in neat cement slurry and pointed in white cement with pigment to match with the shade of tiles laid over and including 10mm thick screed backing layer in CM (1:3) complete all as specified and as directed. |
| 13 | Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth not exceeding 10 sqm on plan and getting out in hard/dense soil complete all as specified and as directed. |
| 14 | M&L for Cement concrete (1:4:8) type D2 as in foundation all as specified and as directed. |
| 15 | M&L for precast cement concrete block masonry with solid blocks in Cum cement concrete 1:3:6, type C5 using 20 mm graded crushed stone aggregate exc10 cm in width and set in CM 1:6 complete. |
| 16 | Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms moulds, mitred/stopped ends etc complete all as specified and as directed. |
| 17 | Material and labour for PCC 1:2:4 type B1 using 20mm graded crushed stone aggregate as in coping including necessary form work complete all as specifed and as directed. |
| 18 | Material and labour for rendering 10 mm thick in CM 1:4 on precast block masonry surfaces finished even and smooth with using extra cement complete all as specifed and as directed. |
| 19 | M&L for Reinforced concrete pipes 300 mm dia, class NP3, laid and jointed complete all as specified and directed. |
| 20 | M&L for PCC 1:3:6 type C-2(40mm grade stone aggregate) as in bed to 300mm dia Reinforced concrete pipes drain pipes including packing under and haunching against the sides of pipe safter they are laid and tested complete all as specified and directed. |
| 21 | Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in any soilcomplete all as specified and as directed. |
| 22 | Removing of excavated soil not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. |
| 23 | M&L for deformed steel TMT bars 10 mm dia and over. cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking end sand binding with mild steel wire (annealed) not. less than 0.9mm dia complete all as specified and as directed. |
| 24 | M & L for precast RCC 1:2:4 type B-1 using 20 mm graded aggregate as in cover slabs set in CM 1:4 including necessary form work complete. |
| 25 | M&L for Surface dressing not exc 150mm deep Hard/ dense soil. Complete all as specified and as directed. |
| 26 | M&L for Hardcore, broken to gauge not exc 63mm for plinth protection/ under floor complete all as specified and as directed. |
| 27 | M&L for 75mm thick concrete type D-2 pcc (1:4:8) (using 40mm graded aggregrates) as in sub base floor all as specified and as directed. |
| 28 | M&L for screed bed or bedding layer of Mortar 15mm thick laying floor finish CM 1:6 all as specified and as directed. |
| 29 | M&L for Chequred cement concrete tiles 30cmx 30cmx 25cm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and pigment all as specified and as directed. |
| 30 | M&L for Providing precast cement concrete type C-I (1:3:6) using 20mm graded stone aggregate, solid blocks or slabs 10cm thick for kerb stone (with plain or interlocking joints as directed) set in CM (1:6) all as specified and as directed. |
| 31 | M&L for Preparation of new plastered surface & applying two coats of colour was over a coat of primer approved colour/shade complete all as specified and as directed. |