Special Repair In Bldg No. T-11 And T- 13 Of 624 Sata Bty, And Spl Repair In Bldg No. T- 12 Mtn Div Sig Regt, At Khumbathang Under Ge Khumbathang
Tender Value
Ref. Documents
Estimated cost
Bid Submission
20 Oct 2022
0 days left
EMD
66530
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Khumbathang → Jammu And Kashmir
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Special Repair In Bldg No. T-11 And T- 13 Of 624 Sata Bty, And Spl Repair In Bldg No. T- 12 Mtn Div Sig Regt, At Khumbathang Under Ge Khumbathang
BOQ
| Sl. No. | Item Description |
| 1 | Sch \"A\" Part-I B/R work:-Dismantling wall and ceiling boards (fibre,pulp, insulation, etc.) or insulation boards/slabs/ blankets, any thickness including cover fillets |
| 2 | Dismantling timber scantling as in fillets, rails, posts, rafters, purlins, etc. under 40 sq. cm in section in any position as in unframed work |
| 3 | S&F 12 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination fixed with nails to timber frame work on walls complete all as specified and directed by Engr-in-Charge. |
| 4 | S&F 9 mm thick prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination and fixed with nails to timber frame work as in walls complete all as specified and directed Engr-in-Charge. |
| 5 | M&L for Plain fillets of second class soft wood, sectional area exceeding 13 Sqcm but not exceeding 25 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed by Engr-in-Charge. |
| 6 | M&L for Plain fillets of second class soft wood, sectional area exceeding 6 Sqcm but not exceeding 13 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or brads complete all as specified and directed by Engr-in-Charge. |
| 7 | M&L for Plain fillets of second class soft wood, sectional area exceeding 3 Sqcm but not exceeding 6 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or bradsin lipping complete all as specified and directed by Engr-in-Charge. |
| 8 | M&L for Plain fillets of second class soft wood, sectional area not exceeding 3 Sqcm in square, rectangular or traingular in section, clean sawn secured with nails or bradsin lipping complete all as specified and directed by Engr-in-Charge. |
| 9 | Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, roof coverings & wall |
| 10 | S&F 0.63mm thick, galvanised, corrugated mild steel sheeting with two corrugationsside lap, fixed with coach screws and washers as in roofs, walls etc, withgrade of zinc coating 275, complete all as specified and directed by Engr-in-Charge. |
| 11 | S&F 0.8mm thick, galvanised, plain mild steel sheeting with two corrugationsside lap, fixed with coach screws and washers as in roofs, walls etc, withgrade of zinc coating 275, complete all as specified and directed by Engr-in-Charge. |
| 12 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of specified colour having tensile strength of 550 Mpa as in roof overing/ cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge. |
| 13 | Demolition of PCC (un-reinforced) in ground floors & pavings n.exc 15 CM thickness below or above ground level, complete all as specified and directed by Engr-in-Charge. |
| 14 | M&L for 25 mm thick PCC 1:2:4 type B-0 using12.50 mm graded crushed stone aggregate as in sub base, flooring and surface finished rough all as specified and as directed. |
| 15 | M&L for Vitrified Ceramic tiles(light shed) 10mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match including laid over 15mm thick screed bed of cement mortar (1:4) complete all as specified and directed. |
| 16 | Taking down Chowkhats or frames exc 1.5 Sqm but not exc. 4 sq. m each(without taking off shutters from the frames) |
| 17 | Taking down Chowkhats or frames not exc. 1.5 sq. m each with shutters (without taking off shutters from the frames) |
| 18 | M&L for 2nd class soft wood plain, solid, straight chowkats and frames, wrought, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints, supplied and fixed |
| 19 | S & F steel window (factory made) with side hung shutter including projecting type hinges, with steel handle and steel peg stay, complete with glazing bar, dovetailed or welded including fly proof shutter including one shop coat of zinc chromate primer and including cutting holes for fixing hold fasts and making good to match with the existing surfaces all as specified and as directed |
| 20 | All as per srl item No. 19 here-in-before but without glazing bar. |
| 21 | M&L for 2nd class hard wood rail and style 35mm thick Plain, framed, panelled shutters Plain framed, (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated supplied and fitted to chowkats for doors. |
| 22 | Dismantling wrought iron or mild steel work of any description not otherwise provided complete all as specified and directed by Engr-in-Charge. |
| 23 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 |
| 24 | S&F Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 for portion framed and hung as gates, including plinth hinges. stop, hand-made sliding bolts, etc complete all as specified and as directed |
| 25 | S&F hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 |
| 26 | S&F Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming toFe-290 Gde-E-165 |
| 27 | Hacking out broken glass (any thickness, size or description) from wooden/metal frames, glazed with putty or fixed with beads all as specified |
| 28 | S&F 4mm thick sheet glass, ordinary qualityin squares n exc 0.5 sq.m in each pane glazing with oil putty complete all as specified and as directed. |
| 29 | S&F 150mm long aluminium anodised, barrel tower bolts of extruded section |
| 30 | S&F 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy. |
| 31 | S&F 100mm long butt hinges, medium weight, cold rolled mild steel |
| 32 | S&F 100mm long extruded aluminium alloy handles, fabricated type, anodised |
| 33 | M&L for preparation of new surfaces of steel of any description , over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed by Engr-in-Charge .. |
| 34 | M&L for preparation of old surfaces of steel of any description , over 10 cm in width or girth and applying one coats of synthetic enamel paintcomplete all as specified and directed by Engr-in-Charge .. |
| 35 | M&L for preparation of new wooden surfaces of any description, not otherwise descri-bed, over 10cm width or girth and applying two coat of synthetic enamel paint over a coat of pink primer complete all as specified and as directed. |
| 36 | S&Fgalvanised mild steel wire cloth 0.63 mm nominal dia and with avg width of apperture1.4 mm fixed with tinned tack or galvanised staple |
| 37 | M&L for 50mm thick cement concrete 1:3:6 type C-1 using 20 mm graded crushedstone aggregate in plinth protection, path, floors & pavingincluding provision of necessary form work finishing the exposed surface even and smooth complete all as specified. |
| 38 | M&L for 75mm thick Cement concrete type D-2, 1:4:8 (using 40mm graded aggregate) as in fdn and subbase to received top layer complete all as specified and directed by Engr-in-Charge. |
| 39 | M&L for 40 mm thick PCC 1:2:4 type B-1 using 20 mm graded crushed stone aggregate as in sub base, flooring and surface finished even and smooth without using extra cement all as specified and as directed. |
| 40 | M&L for glass dividing strips, 3 mm thick and 28mm wide |
| 41 | Demolition of brick or stone/block masonry built in cement mortar including all quions, arches, pillars etc., but excluding ashlar facings, dressed stone works and precast cement articles, complete all as specified and directed by Engr-in-Charge. |
| 42 | M&L for Precast cement concrete type-C-1 block masonary with solid blocks 1:3:6 (using 20mm graded crushed stone aggregate) exc. 10cm in width and setting in cement mortar (1:6), complete all as specified and directed by Engr-in-Charge. |
| 43 | M&L for machine cut kota stone slab flooring 22-25mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete including 20 mm thick screed bed in cement mortar ( 1:4) complete all as specified and directed by Engr-in-Charge. |
| 44 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete. all as specified and directed by Engr-in-Charge. |
| 45 | Sch \"A\" Part-II E/M work:-Taking down carefully copper or aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants,sockets bulk, head fitting, tube light fitting by unscrewing carefully from boards etc and making good, distrubed surface of walls floors etc. |
| 46 | M&L for point wiring with two single core PVC insulated, unsheathed, FRLS type, 1100 volts grade, multistranded copper conductor cable 1.5 sqmm in and including PVC casing caping ISI marked with all connected accessories including one single core multistanded PVC insulated FRLS type, 1.5 sqmm copper conductor cable unsheathed as earth continuity cable including closed recessed wooden terminal boxes of suitable size made of 2nd class hard wood for mounting switches, sockets, fan regulators etc with 3 mm thick plastic laminated sheet top cover complete all as specified.(a)One light /fan/bell point/buzzer point exhaust fan controlled by one nos, one way 5/6 Amps switch. |
| 47 | All as per srl item No 46 here-in-before but One 3 pin socket outlet, 5 Amps, independent board, with cables 1.5 sq. mm size |
| 48 | All as per srl item No 46 here-in-before but one 3 pin socket outlet, 5 Amps on the same board with other switches, with cables 1.5 sq. mm size |
| 49 | S&F in repair Switch piano, flush type single pole, one way 5 Amp |
| 50 | S&F in repair Switch socket combination multipurpose, 5 Amp flush type |
| 51 | S&F in repair Switch socket combination multipurpose, 3 pin 16 Amp flush type |
| 52 | S&F in repairBell, AC, 230 volts, single pole |
| 53 | S&F in repair bell push flush type single pole one way 5 amp. |
| 54 | S&F in repair Ceiling rose 65x50mm, 2 to 3 terminal PVC/polycarbonate, isolated body |
| 55 | S&F in repair Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed by Engineer-in-Charge. |
| 56 | All as per srl item No 46 here-in-before but with conductor of size 2.5 sqmm (Nominal area) for one 3 pin socket outlet 15 Amps on independent board complete and earth continuity wire with 2.5 sqmm PVC insulated stranded copper conductor Cable. |
| 57 | S&F in repair wall mounted LED lights fitting 1x 20W, 4 feet, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete. |
| 58 | S&F in repair LED light fitting mirror type with high output diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 59 | S&F in repair sheet metal powder coated versatile double door SPN distribution board, 8 way suitable for MCB\"s fitted with copper bus bar rated 200amps, neutrallink , earth bar and din rail suitable for use on 240 Volt, 50Hz . |
| 60 | S&F in repair sheet metal powder coated versatile double door SPN distribution board, 4 way suitable for MCB\"s fitted with copper bus bar rated 200amps, neutrallink , earth bar and din rail suitable for use on 240 Volt, 50Hz . |
| 61 | S&F in repair MCB SPN 40 Amp 240 volt AC with 10KA breaking capacity of \"C\" series in distribution boards all as specified and directed. |
| 62 | S&F in repair MCB SP 6-32 Amp 240 volt AC with 10KA breaking capacity of \"C\" series in distribution boards all as specified and directed. |
| 63 | Taking down exhaust fan any type in any position and again refixing in existing location after complete cleaining and oiling complete all as specified and as directed. |
| 64 | M&L for Sub main wiring with two single core 6 sqmm multistranded copper conductor cable FERL, PVC insulated cable 1100 volts grade and 6 Sqmm as continous earthing drawing and includingPVC casing and caping of suitable size with all acessories, complete including taking out of existing wiring all as specified.(Note:-Two runs of 06 Sqmm cable and one run of 06 Sqmm earth cableand one run of PVC casing caping will be measured as one running meter). |
| 65 | M&L for Earthing complete with galvanised steel earth plate electrode of size (600 x 600 x 6.3) mm thick buried directly into ground vertically to depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level, surrounded on all sides by alternate layers of 150 mm thick charcoal and common salt,connected to galvanized earh lead wire of size 4.0 mm by means of lugs, bolts, nuts, washer, check nuts of galvanised iron or steel all as shown in Electrical plate No. 3, wire protected by dia 15 mm bore light grade GI Pipe laid in floor and fixed to wall with proper size of clamps and watering pipe of bore 20 mm dia GI light grade including wire mesh funnel, PCC, earth chamber pit with PCC 1:2:4 type B-1 using 20 mm grade stone aggreate including form work cement mortar including CI Pit cover with frame necessary excavation and earth work in any type of soil including testing on completion for desired result complete including taking out of existing earthing all as specified. |
| 66 | S&F in repair 35 watt new generation energy saving and environmental friendly long life LED security light made up of pressure die cast aluminium housing with high efficient LED as lighting source with toughened glass having IP66 protection and impact resistance of IK07 complete all as specified and as directed by Engr-in-Charge. |
| 67 | Supply, laying and testing XLPE insulated, screened, PVC bedded galvanised steel strip armoured electric power cable (Heavy duty) with aluminium conductor, 1100 Volts grade lay in trenches, ducts, along pole cross sectional area 10 Sqmm 2 Core including taking out old unserviciable cable complete all as specified and directed by Engr-in -Charge. |
| 68 | Excavation in trenches, not exceeding 1.5 m wide and not exc 1.5 m in depth for foundation, laying of pipes etc and not exceeding 10 sqm on plan for manholes etc and getting out in hard/ dense soil, complete all as specified. and directed by Engr-in-Charge. |
| 69 | Returning filling in including spreading, levelling, watering and well remming in layers not exceeding 25cm thick in hard/dense soil complete all as specified. |
| 70 | Removal of excavated soil to distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed |
| 71 | Sand cushioning with fine sand to under ground cables in trenches/ducts in layers of 8 cm deep before laying the cable and 15 cm deep after laying and stretching the cable as specified in clause 19.75 of SSR Part-I.(Note:-Punned thickness shall be measured and paid) |
| 72 | Supply and laying in replacement un reinforced precast concrete cable cover class LV, type I, flat, size 250 mm x 150 mm x 40 mmcomplete all as specified. |
| 73 | Note:-The accepted amount will be arrived after deducting the Sch of credit i.e. Rs .00 and any other reduction if any from quoted amount. |
AI Tender Summary
Tender Timeline
Sep 29, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedOct 20, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 21, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender