Repairs And Maint Of Security / Perimeter / High Mast Lights / Solar Lights / Garden Lights And Connected Items At Along Mil Stn Under Ge 872 Ews, West Siang-Arunachal Pradesh

Military Engineer Services-MES has published Repairs And Maint Of Security / Perimeter / High Mast Lights / Solar Lights / Garden Lights And Connected Items At Along Mil Stn Under Ge 872 Ews. Submission Date for this Tender is 19-10-2022. Tube Light Tenders in West Siang Arunachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34168569
Repairs And Maint Of Security / Perimeter / High Mast Lights / Solar Lights / Garden Lights And Connected Items At Along Mil Stn Under Ge 872 Ews
Open Tender
Indian
Arunachal Pradesh
West Siang
19-10-2022

Tender Details

Repairs And Maint Of Security / Perimeter / High Mast Lights / Solar Lights / Garden Lights And Connected Items At Along Mil Stn Under Ge 872 Ews

Key Value

Document Fees
INR 500 /-
EMD
INR 24000.0 /-
Tender Value
INR 12 Lakhs /-

BOQ Items

NAME OF WORK : REPAIRS & MAINT OF SECURITY/ PERIMETER/ HIGH MAST LIGHTS/ SOLAR LIGHTS/GARDEN LIGHTS & CONNECTED ITEMS AT ALONG MIL STNS UNDER GE 872 EWS
Sl. No. Item Description
1M&L Taking down Street/Perimeter Light Fitting of any type and any capacity from any Height after disconnecting, Opening Cover and Checking of Light Fitting, Repairing as required, Re-fixing the Light Fitting after repaired in Original Position and Providing Connections including Replacing Defective/ Unserviceable Spares/ Parts, complete all as specified and as directed. NOTE :- (a)Cost of Minor Parts/Spares such as Wiring, Mild Steel Bolts, Nuts & Washers, etc. deemed to be included in the Quoted Unit Rate. (b)New Parts/Spares (Quantites are Provisional) will be Measured & Paid separately under respective Items as "Supply only".
2Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 30 Watt, complete all as specified and as directed.
3Supply only Driver (as approved) suitable for LED Street/ Security Light Fitting 45 Watt, complete all as specified and as directed.
4S&F LED Street Light Fitting 30 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.
5S&F LED Street Light Fitting 45 Watt, New Generation, Environmental Friendly, Energy Saving, Long Life, made up of Pressure Die-cast Aluminium Housing with High Power LEDs as Lighting Source and Lens embeded PC Cover having Top Opening, with separate Driver Compartment, IP-66 protected, Impact Resistance of IK-07, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.
6S&F Flood Light 50 Watt Luminaire with High Power COB LED as Light Source, Energy Saving, IP-65 Protectd complete with all Accessories, IP-65 protected, Providing Electric Connections including Taking down Unserviceable Street Light Fitting of any description from any Height, complete all as specified and as directed.
7M&L Street Light Fitting Bracket made out from GI Pipe 40mm Bore (dia), Light Grade, not exc. 1.20 Metre long, bend to required shape and fixing to Poles, etc. with and including Mild Steel Flat Iron Clamps 40x5mm of suitable Length, 2 No. Nuts, Bolts, Washers, etc. including Painting with One coat of Red Oxide Zinc Chrome Primer and Two coats of Aluminium Paint to all Mild Steel Works including Taking down Unserviceable Street Light Fitting Bracket of any description from any Height, complete all as specified and as directed.
8S&F Shock Proof, Rust Proof, Fire Retradrant, Non-transparent Kiosks Pole Box of Size 310x210x120mm made of Engineering Plastic on Piece moulding for Outdoor type, Heavy duty with 4 No. insulated Alunminium Bus-bar of 60 Amp capacity, mounted on Unbreakable Insulators MCB SP, 10 Amp, complete with Aluminium Lugs of suitable Size upto 50 Sqmm including 2 No. Flat Iron 40x3mm Clamps with suitable Size Mild Steel Bolts, Nuts & Washers, etc. and duly Painted on Both Sides with Two Coats of Synthetic Enemel Paint over a Coat of Red Oxide Zinc Chrome Primer including Taking down Unserviceable Pole Box of any description from any Height, complete all as specified and as directed. MAKE : HENSEL/ SCHNEIDER/ SINTEX/ UNIVERSAL SWITCH GEARS CONTROL or as approved by GE.
9M&L Painting LT Steel Tubular Pole 8.5/ 9.0 Metre High including Cross Arms, Channel, Flat Iron Clamps, etc. with One coat of Aluminium Paints and Numbering of Code in letter Size not less then 50mm in Black Paints and Painting of Pole with Strips 300mm high (5 Nos.) around the Pole with Two different Colour SyntheticEnamelled Paint for Pole 7.5 Metre height above Ground Level, complete all as specified and as directed.
10S&F Globe shaped LED Post Top Lantern Fitting 20 Watt in Frosted Finish made up of Polycarbonate suitable for LED Lamp (B-22 base) complete with all Accessories with LED Lamp 20 Watt and Providing Connection including Taking down Unserviceable Post Top Lantern Fitting of any description, complete all as specified and as directed.
11S&F LED Post Top Fitting 25 Watt, Energy Saving, Environmental Friendly, Long Life, Asthetically designed with Symmetrical Light Distribution, Spun, Aluminium Landscape Luminare, IP-65 Protection with High Power LED as Light Source including Lamp 25 Watt, Providing necessary Electrical Connection including Taking down Unserviceable Post Top Fitting of any description, complete all as specified and as directed.
12M&L PVC Insulated, Multi-stranded, FRLS Copper Conductor Cable of Size 1.0 Sqmm 3 Core, fixing from Fitting to Junction Box, complete all as specified and as directed.
13M&L Preparing Surfaces of Garden Light Pole 3.00 Metre High including All Accessories of Pole such as GI Bracket, Clamps, etc. and applying One Coat of Aluminium Paint (Superior quality), Painting Bottom Portion of 60 Cm Length 30 Cm Wide 4 No. with Two Coats of Synthetic Enamel Paint (Black and Yellow) in Alternate Strips of Black and White Paint, complete all as specified and as directed.
14Dismantling Unserviceable LT Steel Tubular Pole of any description and any Size including Demolition Cement Concrete (if required on Ground) and Made Good disturbed Ground, complete all as specified and as directed. NOTE : Unserviceable Pole will be dismantled at Ground Level and disturbed Ground will Made Good as directed for which Earthwork, Demolition Cement Concrete, etc. will not be Measured and Paid separately.
15Dismantling Cross Arms, Mild Steel Channel, Angle Section, Flat Iron, Mild Steel Rod, etc., complete all as specified and as directed.
16Taking down ACSR Conductor of any Size including Line Spacers of OH Electric Lines from LT Electric Poles, complete all as specified and as directed.
17Disconnecting & Taking down/out Unserviceable LT Cable of any Size and any description from Trenches, Floors, Walls, GI Pipes, etc. incuding Serviceable (if any) Cables, Bricks/Cable Protection Cover, etc. keep in Safe Custody for re-use, complete all as specified and as directed. NOTE : Necessary Earth Works will be Measured & Paid under appropriate Items.
18Excavating in Trenches, not exc. 1.50 Metre Wide and Depth not exc. 1.50 Metre for Taking out/up and Laying of Cable, Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
19Excavating in Trenches, not exc. 1.50 Metre Wide and Depth exc. 1.50 Metre but not exc. 3.00 Metre for Electric Pole, etc., Forming Surfaces to required Foundation, etc. and getting out as in Soft/Loose Soil, complete all as specified and as directed.
20Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, Providing Heaps along the Route of the Cable Line with Surplus Soil in Soft/ Loose Soil, complete all as specified and as directed.
21Removing excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point in Soil, complete all as specified and as directed.
22Drilling/Making Hole (Horizontally) under Roads/ Hardstanding, etc. by any means suitable for passing GI Tubing 40mm to 80mm bore (dia), complete all as specified and as directed.
23M&L Cutting Existing Road not exc. 1.00 Metre in Depth and not exc. 0.50 Metre in Wide including Making Good the same to match the Original Surface level with Cement Concrete 1:3:6 (40mm graded stone aggregates) after laying of Cables, Well Ramming and leveling in layers, etc., complete all as specified and as directed. NOTE: Cement Concrete will be Measured & Paid separtely under appropriate Item
24M&L Cement Concrete 1:4:8 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
25M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) in Foundation, Filling and Mass Concrete, etc. including Use and Waste of Formwork as required/ordered, complete all as specified and as directed.
26M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Copping of Electric Poles, etc., weathering slightly rounded or chamfered angle and throating, finishing all Exposed Faces of Concrete including necessary Formwork, complete all as specified and as directed.
27M&L Steel Tubular Swaged Pole Type 410 SP-31 (9.0 Metre long) complete with Mild Steel Base Plate, Finial Taper Plug, Bolts, Nuts & Screws, etc. as specified including One coat Aluminium Paint over One Coat of Red Oxide Zinc Chrome Primer, providing 3 No. Band/ Strap with Paint Black/ Yellow Colour 300mm apart from Plinth Block and numbering of Pole/ Painting embedded portion of Pole with One coat of Bituminous Paint, complete all as specified and as directed. NOTE : Necessary Earth Work & PCC will be Measured and Paid separately under relevent Items.
28M&L Cross Arms, Bracings, Supports, Clamps and Back Plates, fabricated from Structural Steel Sections including Nuts, Bolts, Washers, etc., welding, bending cold or hot, drilling holes for Bolts, in any shape or Size as indicated or directed and applying Two coats of Aluminium Paint over a coat of Red Oxide Zinc Chromium Primer after preparation of Surfaces, complete all as specified and as directed.
29S&F Insulator Pin type, 100mm height, 65mm dia for 1100 Volt grade, Porcelain, Vitreous, white, brown or green including One Galvanised Mild Steel Spindle Two Galvanised Iron Washer and One Galvanised Iron Nut including Taking down Unserviceable Insulator, complete all as specified and as directed.
30S&F Insulator Shackle type, Porcelain, Vitreous, white brown or green of Size 75mm High & 90mm dia including Galvanised Mild Steel Straps of Section 31x3.0mm,12mm dia Insulator Bolts, Nuts, Washer, etc. for Working Pressure 1100 Volt grade including Taking down Unserviceable Insulator, complete all as specified and as directed.
31M&L ACSR Conductor of any Size for LT Over Head Line including Stringing Conductor fixed on Poles and binding with Aluminium Binding Wire, etc., complete all as specified and as directed. NOTE : Sizes of Conductor will be as per Site requirement as directed by Engineer-in-Charge.
32S&F PVC Fibre Separator for LT Line 1100 Volt Over Head Conductor 3/4-Wire System for Horizontal Spacing of Conductor complete with Nut and Bolts minimum 2 No. to prevent the Lines Touching Each Other on Heavy Winds as a Preventive Arrangement to the Existing System, complete all as specified and as directed.
33M&L XLPE insulated, armouredheavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 10 Sqmm, 2 Core, laid in Trenches/ Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GIPipe, etc. will be Measured and Paid separately under relevent Items.
34M&L XLPE insulated, armouredheavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 10 Sqmm, 4 Core, laid in Trenches/ Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GIPipe, etc. will be Measured and Paid separately under relevent Items.
35M&L XLPE insulated, armouredheavy duty, Electric Cable with Aluminium Conductor, 1100 Volt grade, Cross-sectional area 16 Sqmm, 4 Core, laid in Trenches/ Ducts or Passing through Pipes or Fixing on Poles, etc., complete all as specified and as directed. NOTE : Necessary Earth works, Sand cushioning, Cable Protection Cover & GIPipe, etc. will be Measured and Paid separately under relevent Items.
36M&L Sand Cushioning (dry) in Trenches/Ducts for protection of UG Cables (below, above and around the UG Cable laid) of 23 Cm Spread thickness (8 Cm in depth before laying the Cable and 15 Cm in depth after laying the Cable) and consolidated (punned) upto 180mm thickness, complete all as specified and as directed. NOTE : For the purpose of Payment, Punned thickness of Sand Cushioning only will be Measured.
37Supply & Laying Unreinforced Pre-cast Concrete Cable Cover of Size 250x150x40mm thick, Class LV, Type 1, Flat, Concrete grade M-20 minimum, complete all as specified and as directed.
38M&L Galvanised Steel Tubing Pipe 40mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron 40x4.0mm Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
39M&L Galvanised Steel Tubing Pipe 50mm bore (dia), Light grade with Bend, laid in Trenches or under Roads/ Flooring/ Culverts and/or fixing to Electric Poles with suitable Size Mild Steel Flat Iron 40x4.0mm Clamps, Bolts, Nuts, Washers, etc., complete all as specified and as directed.
40M&L Earthing with Galvanised Earth Plate Electrode 600x600x6.0mm thick, buried directly in Ground vertically to a depth not less than 2.25 Metre below Ground Level with Top Edge of Earth Plate at depth not less than 1.50 Metre below normal Ground Level, connectedto GalvanisedEarth Lead Wire 4.0mm dia by means of Bolts, Nuts, Check, Nuts and Washers of Galvanised Iron or Steel and Earth Wire protected with and including GI Pipe 15mm bore (dia) Light grade, connected to Test Point upto 7.50 Metre away from Earth Electrode situated, Earth Plate surrounded by a packed thickness of Char Coal or Coke Dust mixed with Common Salt in alternate layers of not exc.150mm thick, PCC Pit in Cement Concrete 1:3:6 (20mm graded stone aggregate) and Pre-cast RCC Cover Slab of Size 350x350x50mm in Cement Concrete 1:2:4 (20mm graded stone aggregate), reinforced with 10mm dia TMT Bars @ 100mm Centre to Centre in both ways, GI Wire Mesh, PGI Funnel with GI Watering Pipe 20mm bore (dia) Medium grade including necessary Excavation in Soft/ Loose Soil, Returning, Filling in and Removal of surplus Spoil upto a distance of 50.00 Metre and all as shown in Electrical Plate No. 3 of MES Schedule Part-I and Testing on Completion including Taking down/ out Unserviceable Earthing of any description, complete all as per specified and as directed.