Provision Of Training Equipment And Addition / Alteration To Allied Training Infrastructure At Afa Hyderabad- Schedule A Part -I ( B / R Portion ) :-Surface Excavation Not Exceeding 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Hard / Den, hyderabad-Telangana

Military Engineer Services-MES has published Provision Of Training Equipment And Addition / Alteration To Allied Training Infrastructure At Afa Hyderabad- Schedule A Part -I ( B / R Portion ) :-Surface Excavation Not Exceeding 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Hard / Den. Submission Date for this Tender is 20-10-2022. Coats and Jackets Tenders in hyderabad Telangana. Bidders can get complete Tender details and download the document.




Tender Notice

34163431
Provision Of Training Equipment And Addition / Alteration To Allied Training Infrastructure At Afa Hyderabad- Schedule A Part -I ( B / R Portion ) :-Surface Excavation Not Exceeding 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Hard / Den
Open Tender
Indian
Telangana
hyderabad
20-10-2022

Tender Details

Provision Of Training Equipment And Addition / Alteration To Allied Training Infrastructure At Afa Hyderabad- Schedule A Part -I ( B / R Portion ) :-Surface Excavation Not Exceeding 30 Cm Deep And Averaging 15 Cm Deep And Getting Out In Hard / Dense Soil Complete All As Specified And As Directed. 2 Removing Excavated Material / Soil To A Distance Exc 250 Mtr And Not Exc 500 Mtr Anddepositing Where Directed At A Level Not Exc 1.5 Mtr Above The Starting Point Complete All As Specified And As Directed. 3 Excavating In Trenches, Not Exc 1.5 Mtr Wide And Not Exc 1.5 Mtr In Depthfor Foundations, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. Not Exc 10 Sq M On Plan And N Exc 1.5 Mtr In Depth And Getting Out In Hard / Dense Soil Complete All As Specified And As Directed. 4 M&L For Excavation In Trenches Not Exc 1.5 Mtr Widthand Not Exc 1.5 Mtr In Depth And Getting Outin Any Type Of Soil Complete All As Specified And As Directed. 5 Returning, Filling In, Including Spreading, Levelling, Watering And Well Ramming In Layers Not Exc 25 Cm Complete All As Specified And As Directed. 6 Removing Excavated Soil Not Exc. 50 Mtr And Depositing Where Directed At A Level Not Exc. 1.5 Mtr Above The Starting Point Complete All As Specified And As Directed. 7 M& L For Plain Cement Concrete Pcc1:4:8 Type D-2 Mix ( Using 40 Mm Graded Stone Aggregate ) As In Foundations, Filling And Mass Concrete Complete All As Specified And As Directed. 8 M&L For Rcc M- 25As In Foundations, Including Rafts, Footings, Foundation Beams; Plinth Beams; Bases For Columns, Etc.; Basement Slabs, Under-Reamed Piles And Mass Concrete Complete All As Specified And As Directed. 9 M&L For Rcc M-25As In Columns, Pillars, Piers, Posts And Struts Complete All As Specified And As Directed. 10 M&L For Rcc M-25As In Beams, Cantilevers, Bressummers, Lintels Over 1.5 Mtr Span Complete All As Specified And As Directed. 11 M&L For Rcc M-25Slabs Supported On Walls, Beams And Columns In Floors, Roofs, Landings, Balconies, Canopies, Deck Slabs And In Shelves And The Like Complete All As Specified And As Directed. 12 M&L For Rcc M-25As In Chajjas Etc Complete All As Specified And As Directed. 13 M&L For Formwork To Sides Of Concrete Foundations, Footings, Bases Of Columns, Raft And Raft Beams, Sides And Soffits ( If Any ) Of Foundation And Plinth Beams; And Similar Work; Vertical Or To Batter Surfaces Complete All As Specified And As Directed. 14 M&L For Formwork To Sides Of Pillars, Posts, Struts, Piers, Columns And Stanchionscomplete All As Specified And As Directed. 15 M&L For Formwork To Sides And Soffits Of Floor Or Roof Beams, Beam Haunchings, Girders, Bressummers, Lintels, Cantilevers, Shelves Including Sup- Ports, Overhangs, Etc. Also Splays Between Floors And Beams, Etc.Complete All As Specified And As Directed. 16 M&L For Formwork To Soffits Of Suspended Slabs Such As Roof Slabs, Floor Slabs, Landings And Similar Work; Not Exceeding 200 Mm Thick ( Horizontal Or Sloping ) Complete All Asspecified And As Directed. 17 M&L For Formwork Tochajjas, Troughs And Similar Items Including Edges For Rough Finished Surfaces Of Concrete Flat Complete All As Specified And As Directed. 18 M& L For Pre-Cast Cement Concrete Block Masonry With ( 1:3:6 ) Type C-1 Mix Using 20 Mm Graded Stone Aggregate Solid Blocks, Exc. 10 Cm In Width And Setting In Cement Mortar 1:6, Complete All As Specified And As Directed. 19 M&L For Providing Precast Cement Concrete With Pcc 1:3:6 Type C- 1 Mix Using 20 Mm Graded Stone Aggregate Solid Building Blocks Or Slabs Not Exc 10 Cm Thick ( With Plain Or Interlocking Joints As Directed ) Set In Mortar 1:4Asin Walls Complete All As Specified And As Directed. 20 M&L For Mild Steeltmt Bars 10 Mm Dia And Over Cut To Length Bent To Shape Required Including Crancking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9 Mm Dia Complete All As Specified And As Directed. 21 M&L For Mild Steeltmt Bars 6 Mm To 8 Mm Dia Cut To Length Bent To Shape Required Including Crancking, Bending Spirally For Hooping For Columns, Hooking Ends And Binding With And Including Mild Steel Wire ( Annealed ) Not Less Than 0.9 Mm Dia Complete All As Specified And As Directed. 22 Description All As Per Ser Item No 20 Abovebut As In Stirrups, Spacers And Binders Etccomplete All As Specified And As Directed. 23 M & L For Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Wall Surfaces In Cm 1:6 And Rendering Is To Befinished Even & Smooth Without Using Extra Cement Complete All As Specified And As Directed. 24 M & L For Rendering 5 Mm Thick On Fair Faces Of Brick Work Or Concrete Ceiling Surfaces In Cm 1:3 Finished Even & Smooth Without Using Extra Cement Complete All As Specified And As Directed. 25 M & L For Rendering 15 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cm 1:4 Finished Even & Smooth Without Using Extra Cement With Using Wpccomplete All As Specified And As Directed. ( Note :- Wpc Shall Be Measured And Paid Separately ) . 26 M & L For Rendering 10 Mm Thick On Concrete Surfaces Of Roof In Cm 1:3And Rendering Is To Befinished Even & Smooth Without Using Extra Cement With Using Wpc Complete All As Specified And As Directed. ( Note :- Wpc Shall Be Measured And Paid Separately ) 27 Supply Only Of Integral Waterproofing Compound Of Approved Makes Complete All As Specified And As Directed. 28 M&L For Preparation Of New Plastered Surfaces Of Walls And Applying Two Coats Of Oil Bound Distemperover A Coat Of Primer Complete All As Specified And As Directed. 29 M&L For Applying Two Coats Of Oil Bound Distemper On Ceilings Including Reparation Of New Plastered Surfaces Over A Coat Of Primer Complete All As Specified And As Directed. 30 M&L For Preparing Newly Plastered Surfaces Of Walls And Applying Two Coats Of Cement Based Paint Over A Coat Of Primer Complete All As Specified And As Directed. 31 M&L For Hardcore Of Gauge N Exc. 63 Mm, Deposited, Spread And Levelled In Layers N Exc. 15 Cm Thick, Watered And Rammed To A True Surface Complete All As Specified And As Directed. 32 M& L For 100 Mm Thick Plain Cement Concrete1:4:8 Type D-2 Mix ( Using 40 Mm Graded Stone Aggregate ) As In Sub Base Flooring Etccomplete All As Specified And As Directed. 33 M&L 25 Mm Thick Plain Cementconcrete1:2:4 Type B-1 Mix ( Using 20 Mm Graded Stone Aggregate ) As In Floor Finish Concrete Complete All As Specified And As Directed. 34 M & Lfor Coloured Non-Skid Ceramic Tiles ( Square / Rectangular ) 7 To 8Mm Thick In Floors, Area Of Each Tile Exc.0.11 Sqm But N.Exc 0.18 Sqm, Set And Jointed In Neat Cement Slurry And Pointed In White Cement Mixed With Matching Pigment Over And Including 20 Mm Thick Screed Bed In Cm 1:6 All Complete All As Specified And As Directed. 35 M&L For Glazed Ceramic Tiles In Vertical Surfaces 350 X 250 X 7 Mm / 450 X 350 X 7 Mm Thick Set And Jointed In Neat Cement Slurry And Pointed In White Or Colour Cement To Match Over 10 Mm Thick Screed Plasterin Cement Mortar 1:4 To Receive Wall Tiles Etc Complete All As Specified And As Directed. 36 S&F Factory Made Solid Panel Pvc Door Shutter 30 Mm Thick ( Style ) Consisting Of Frame Made Out Of M.S. Tubes For Top & Bottom Rails. M.S. Frame Shall Be Covered With Heat Moulded Plain Colour Pvc ‘C’ Channel Having A Pvc Sheet Strip Of 20 Mm Width Stuck Inside With Solvent Cement For Stiles And Plain Colourpvc Sheets For Top Rail, Lock Rail & Bottom Rail On Either Side & As Gap Insert For Top Rail & Bottom Rail; Panelling Of Plain Colour Pvc Sheet To Be Fitted In The M.S. Frame Welded / Sealed To The Stiles & Rails With Suitable Pvc Sheet Beading, And Joined Together With Solvent Cement, Suppling & Fixing In The Frame At Site As Per Specification & Drawing Complete All As Specified And As Directed. 37 S& F Solid Pvc Door Frame Of Size 50 Mm X 47 Mm Made Out Of 5 Mm Plain Colour Pvc Sheet Reinforced With Ms. Square Tube, Suppling & Fixing In Opening As Per Specification & Drawing Complete All As Specified And As Directed. 38 M&L For Anodised Aluminium Window Andventilator Shutters, Top Hung Type Without Sash Bars, Aluminium Sections Weighing 0.55 Kg / M Including Necessary Joining Cleats, Glazing Clips, Rubber Packing, Anodised Aluminium Snap Beading, Screws, Anodised Aluminium Fittings Such As Peg Stays 150 Mm Long ( 1 No. ) . Hinges Type B-21 100Mm Long ( 2 Nos. ) Suitable Handle ( 1No. ) Complete All As Specified And As Directed. 39 S&F 3.0 Mm Thick Figured Glass, Pin Head Type And Glazing With Aluminium Beadingin Squares N.Exc 0.5 Sq Mtr In Each Pane Complete All As Specified And As Directed. 40 S&F 100 Mm Stainless Steelbutt Hinges, Cold Rolled Medium Weightcomplete All As Specified And As Directed. 41 S&F100 Mm Aluminum Anodised Barrel Tower Bolts Of Extruded Sectioncomplete All As Specified And As Directed. 42 S&F 100 Mm Extruded Aluminium Anodised Alloy Handles Fabricated Typecomplete All As Specified And As Directed. 43 S&F250 Mm Aluminum Alloy Anodised, Sliding Door Bolt With Hasp, Staple ( Bolt Type ) And Fixing Clips Of Sheet, Cast Or Extruded Sections And Fixing Bolts And Sliding Bolts Of Extruded Sections Or Cast Aluminum Alloycomplete All As Specified And As Directed. 44 S&F Vitreous China Wash Down Water Closet ( Pedestal Pattern ) White ( Excluding Fixing Bolts, Flushing Cistern ) With Plastic Water Closet Seat Including Fixing Of Flush Pipe To Pedestal Pan Including All Joints Complete All As Specified And As Directed. 45 S&F 10 Ltr Capacity Pvc Valve Less, Syphonic Action Type Flushing Cistern, Low Level, White, With Inlet, Ball Valve, Float And Handle Including Brackets Complete All As Specified And As Directed. 46 S&Fvitreous China Wash Basin, White, Oval Type, Size 550 Mm X 440 Mm Excluding Taps, Waste, Chain And Plug And Porcelain Stopperoval Type But Including Brackets Cp Waste Coupling ( Flat Back Or Angle Back Type ) Any Size And 32 Mm Dia Waste Pipe, Including Cutting For And Pinning In Ends Of Brackets Or Erecting Stand Including Waste Pipe Complete All As Specified And As Directed. 47 S&F 15 Mm Diabib Taps, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Andfixed To 15 Mm Bore Pipecomplete All As Specified And As Directed. 48 S&F 15 Mm Borepillar Taps, Cast Copper Alloy Fancy Type, With Capstan Heads, Chromium Plated, Screwed Down High Pressure, With Or Without Lettered Hot Or Cold With Long Screwed Shanks And Fly-Nuts, Screwed For Iron Pipe And Fixed Complete All As Specified And As Directed. 49 S&F Of Stop Valves / Angle Valves15 Mm Dia Cast Copper Alloyfancy Type Cp Screweddown High Pressure With Crutch Or Butterfly Handle Screwed Both Ends For Iron Pipe Or For Unions, Of 15 Mm Boreetc Completeall As Specified And As Directed 50 S&F Of Vitreous China Urinals, Half Stall Bowl Type ( Back Or Corner Wall Type ) , Complete Including Providing And Fixing Plugs, Bedding Urinal Against Wall In Cement Mortar 1:2, Securing Urinal To Plugs With And Including 60Mm Long Brass Screws, Pointing Around Urinal Back In Cement; Fixing Automatic Flushing Cistern With Brackets, Flush Pipe, Grating And Union For Discharge Pipe. ( Exclusive Of Fixing Supply Pipe To Flushing Cistern, Trap And Waste Pipe ) Complete All As Specified And As Directed. 51 S & Fpvc Connections 15 Mm Size With Ptmt Nuts Of Length 450 Mmcomplete All As Specified And As Directed. 52 S&Fpvc ( Swr ) Floor Trap, Plain With Grating Including Jointing With Solvent Cement Complete All As Specified And As Directed. 53 S&F 600 Mm X 450 Mmmirror Of Selected Quality Glass, Mounted On 6Mm Thick Ac Building Board Or Commercial Plywood And Fixed To Wooden Plugs With Chromium Plated Brass Screws And Cup Washers Complete All As Specified And As Directed. 54 S&F Of 15 Mm Bore Steel Tubing Medium Grade Galvanised With All Fittings And Fixed Complete To Walls And Ceilings Or Laid In Floors Etc Including Taking Down Old Complete All As Specified And As Directed. 55 S&F Of 20 Mm Bore Steel Tubing Medium Grade Galvanised With All Fittings And Fixed Complete To Walls And Ceilings Or Laid In Floors Etc Including Taking Down Old Complete All As Specified And As Directed. 56 S&F Of 25 Mm Bore Steel Tubing Medium Grade Galvanised With All Fittings And Fixed Complete To Walls And Ceilings Or Laid In Floors Etc Including Taking Down Old Complete All As Specified And As Directed. 57 S & F Pvc ( Swr ) Pipes Of 110 Mm Dia Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls / Floors Including Connections Complete All As Specified And As Directed 58 S & F Pvc ( Swr ) Pipes Of 75 Mm Dia Single Socketed In Any Length With Rubber Ring Joints Fixed To Walls / Floor Including Connectionscomplete All As Specified And As Directed 59 S&F Of 110 Mm Bore Pvc ( Swr ) Bends Any Radiuscomplete All As Specified And As Directed. 60 S&F Of 75 Mm Bore Pvc ( Swr ) Bends Any Radius Complete All As Specified And As Directed. 61 S&F Pvc 110 Mm Bore ( Swr ) Junction Single, ( Single T ) Equal Or Unequal Complete All As Specified And As Directed. 62 S&F Pvc ( Swr ) Vent Cowl 110 Mm Bore Complete All As Specified And As Directed. 63 M& L For 75 Mm Thickplain Cement Concrete1:3:6 Type C-1 Mix ( Using 20 Mm Graded Stone Aggregate ) As In Plinth Protection Laid In Alternate Bays Not Exceeding 2 Sqm Each And Finished Fair On Top Without Using Extra Cement. 6Mm Wide Joints Shall Be Provided Throughout The Thickness Of Plinth Protection In Concrete Bays. All Joints In Bays Of Concrete, Shall Be Filled With Mastic Filling Comprising Of One Part Of Heated Bitumen Vg-30 Grade And 3 Parts Of Sand ( All By Weight ) . Complete All As Specified And As Directed. 64 Excavating In Post Holes ( Or Similar Holes ) Each N Exc 0.5 Cum, Getting Out, Returning, Filling In And Ramming Earth Or Broken Rubble Mixed With Earth Around, In Layers Not Exceeding 25Cm, Watering, And Removing Surplus Soil To A Distance N Exc 50M And Making Good Surface In Hard / Dense Soil Complete All As Specified And As Directed. 65 M&L For Plain Cement Concrete 1:2:4, Type B-2Mix Using 40 Mm Graded Stone Aggregate As In Foundations, Filling And Mass Concrete Etc Complete All As Specified And As Directed. 66 M&L For Pcc1:2:4, Type B-0 Mixusing 12.5 Mm Graded Stone Aggregate As In Copings, Kerbs And The Like Including Weathering, Slightly Rounded For Chamfered Angles And Threading, Including Necessary Formworkcomplete All As Specified And As Directed. 67 Dismantling Wrought Iron Or Ms Work Of Any Description And In Any Position Complete All As Specified And As Directed. 68 S&Fof Steel Work As In Tubular Posts, Trusses Including Special Shaped Washer Etc. Complete Using Erw Or Induction Butt Welded Tubes Conforming To Is 1161-1979 Grade St.-240 Complete All As Specified And As Directed. 69 M&L For Ms Plates Fe 410 Gd E250 In Trusses ( Framed ) , Etc Connecting With Bolts / Welding As Base Plates / Connecting Platesetc Complete All As Specified And As Directed. 70 M&L For Bands, Straps, Supports Or Stays For Rainwater, Ventilating Pipes, Including Bolts, If Required; Hooks ( Stay ) , Heavy, For Large Gates; Hook And Pintle Hinges; Large Hasps And Staples; Chains; Hand Made Sliding Bolts; Clamps; Hold Fasts; Wall Ties; Hooks For Hanging Fans; Plain Angle Cleats For Securing Purlins To Wood Trusses Or Rafters; Knee Piece Inserts; Two Way And Three Way Straps, Plate Washers And Similar Small Articles Conforming To Fe 290 Gde E-165 Complete All As Specified And As Directed. 71 S&F Mild Steel Screw Bolts ( Machine Made ) With Hexagonal Or Square Heads At One End And Screwed The Other Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nut N Exc 5 Cm Long Dia Of Neck 11 To 15 Mm Complete All As Specified And As Directed. 72 S&F Mild Steel Screw Bolts ( Machine Made ) With Hexagonal Or Square Heads At One End And Screwed The Other Or Screwed Both Ends, Each Screwed End To Be Fitted With Washers And One Hexagonal Or Square Nutexc 30 Cm Long Dia Of Neck Exc 12 N Exc 20 Mm Complete All As Specified And As Directed. 73 Dismantlingplain Or Corrugated Steel Sheeting, Any Gauge Thickness Including Roof Coverings Complete All As Specified And As Directed. 74 S&F 6 Mm Thick Multiwall Polycarbonate Sheet Make As Approved By Ge With Side Laps Using H Channels Including Taps , Adhesive Etc As Per Manufacturers Instructions Andfixed With Purlin Member Supports And Stainless Steel Self Driven Screws And Washers In Roof Etc Complete All As Specified And As Directed. 75 S&F 2 Mm Thick Diamond Polycarbonate Sheet Fixed Into The Roof / Wall Etc And Fixing With Self Driven Screws Complete All As Specified And As Directed. 76 M&L For Preparation Of New Steel Surfaces Of Any Description And Applyingtwo Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Zinc Crome Primer On Surfaces Over 10 Cm In Width Or Girth, Not Otherwise Described Complete All As Specified And As Directed. 77 M&L For Preparation Of Old Steel Surfaces And Applyingone Coat Of Synthetic Enamel Paint On Surfaces Of Any Description, Over 10 Cm In Width Or Girth, Not Otherwise Described Complete All As Specified And As Directed. 78 M&L For Framed Work Such As Grills, Gratings, Etc., With Ends Of Bars Shouldered And / Or Riveted, Or Forged Into Spikes; Framed Guard Bars; Barred Iron Doors; Ladders; Framed Balusters; Walk Ways; Railings; Framework Of Water Tanksand Similar Work Conforming To Fe Fe 290 Gde E-165 Complete All As Specified And As Directed. 79 S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Corrugated Sheet 0.5 Mm Thick Of An Colour Having Tensile Strength Of 550Mpa As In Roof Covering / Cladding To Wall With Self Tapping Screws Complete All As Specified And As Directed. 80 S&F Pre Painted Galvalume Aluminium Zinc Coating Gi Based Plain Sheet 0.5 Mm Thick Of An Colour Having Tensile Strength Of 550Mpa As In Roof Covering / Cladding To Wall With Self Tapping Screws Complete All As Specified And As Directed. 81 M&L For 75 Mm Thick Pcc 1:4:8 Type D-2 Mix ( Using 40 Mm Graded Stone Aggregate ) As In Floor , Sub Base Etc Complete All As Specified And As Directed. 82 M&Lfor Pressed Precast Concrete Interlocking Paver Block Any Shape And Size Conforming To Is 155658 - 2006 Of 60 Mm Thickness M-35 Grade With Grey Cement And Pigment And Including Required Sand Cushing, Sealing The Edgescomplete All As Specified And As Directed. 83 M&L For Rendering 10 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cm 1:4And Rendering Is To Be Finishedeven And Smooth Without Using Extra Cement Complete All As Specified And As Directed 84 M&L For Preparing Old Wall Surfaces And Applying One Coat Of Cement Base Paintcomplete All As Specified And As Directed. 85 M&L For 100 Mm Thick Plain Cementconcrete1:2:4 Type B-1 Mix ( 20 Mm Graded Stone Aggregate ) As In Floor Finish Concrete Etc Complete All As Specified And As Directed. 86 M&L For Forming Contraction ( Dummy ) Joints 65 Mm Deep X 10 Mm Wide, Filled With Sealing Compound Grade A Complete All As Specified And As Directed. 87 M&L For Providing Precast Reinforced Cement Concrete1:2:4 Type B-1 Mix ( Using 20 Mm Graded Stone Aggregate ) As In Cover Slabs Icluding Necessary Form Work Complete All As Specified And As Directed.Note :- Reinforment Steel Shall Be Measured And Paid Separately 88 Demolition Of Stone Slabs And Tiles Of Any Description Or Thickness In Floors, Aprons Etc Laid, Bedded And Pointed In Any Mortar Complete All As Specified And As Directed. 89 M&L For Roughening Surfaces Of Old Concrete Floor By Picking, Sweeping, Clean And Washing Down With Water To Remove Dust, Etc. Complete All As Specified And As Directed. 90 M&L For Screed Bed Or Bedding Layer Of Mortar 20 Mm Thick For Laying Floor Finishesin Cm ( 1:4 ) Etccomplete All As Specified And As Directed. 91 M&L For Machine Cut Kota Stone Slab Flooring 20-25 Mm Thick Over Cement Screed Base Laid And Jointed With Grey Cement Slurry Mixed With Pigment To Match The Shade Of The Slab Including Rubbing And Polishing Complete All As Specified And As Directed. 92 M&L For 20 Mm Thick White Marble ( Makarana White ) Tiles Machine Cut Asin Flooring Laid Over Cement Scrred And Jointed With Grey Cement Slurryin Between Kota Stone Flooring As Boarders Incuding Cutting And Polishing Complete All As Specified And As Directed. 93 Taking Down Cement Plaster From Walls Built In Cement Mortar, Etc. Including Raking Out Joints, Hacking For Key, Scrubbing Down With Water, Etc. To Receive Plaster. ( For Dado ) Complete All As Specified And As Directed. 94 Dismantling Floor, Hearth Or Wall Tiling Including Cement Mortar Bedding ( But Not Backing ) , Removing Serviceable Tiles To Store And Rubbish Off The Premises Complete All As Specified And As Directed. 95 M&L For Providing And Fixing In True Horizontallevel False Ceiling Grid System Manufactured By M / S Armstrong World Industries Us / Uk Using Hot Dipped Galvanised Steel Section Exposed Surface Chemically Cleaned Capping, Prefinished In Baked Polyester Paint, Main Tee Of Size 3000 X 32 X 15 Mm At Every 1200 C / C, Max And 1200 Mm Cross Tee Of Size 1200 X 32 X 15 Mm At Every 600 Mm C / C, Max And 600Mm Cross Tee Of Size600x32x15mmat Every 120 Mm C / C Max And 3000X19x19mm Wall Angle All Around The Wall To Form Grid Size Of 600X600mm And Suspending The Grid Using 2 Mm Pro-Straightened Gi Wire And 6 Mm Nylon Raw Plug At Every 1299 Mm Intervals At The Main Tee And Laying Armstrong Ultima Micro Look Manufacturedby Armstrong World Industries Complete All As Specified And As Directed. 96 M&L For Preparation Of Old Wooden Surfaces And Applyingone Coat Of Synthetic Enamel Paint On Surfaces Of Any Description, Over 10 Cm In Width Or Girth, Not Otherwise Described Complete All As Specified And As Directed. 97 M&L For Plain Cement Concrete1:2:4 Type B-1 Mix ( Using 20 Mm Graded Granite Stone Aggregate ) As In Benching Of Man Holes Including Forming Centre Channels Half Round Or 1 / 4 Section Complete All As Specified And As Directed. 98 M &L For Pcc 1:4:8 Type D-2Mix ( Using 40 Mm Graded Granite Stone Aggregate ) In Concrete Bed To Drain Pipes Incluyding Packing Under And Haunching Against The Sides Of Pipes After They Are Laid And Tested For Pipes Of 150 Mm Bore Complete All As Specified And As Directed. 99 M&L For Pre-Cast Rcc Slabs As In Manhole Covers In 1:2:4 Type B1 Using 20 Mm Graded Stone Aggregate, Set In Cement Mortar ( 1:4 ) Including Use And Waste Of Form Work Complete All As Speciied And As Directed. 100 M & Lfor 150 Mm Dia Reinforced Concrete Pipes Of Class Np-3 With One Collar Per Length Of Pipe Complete All As Specified And As Directed. 101 M&L For Extra Forming Forfair Finished Drain Or Channels Of 30 Cm Inner Girth In Cement Concrete, Using Extra Cement Including Forms, Moulds, Mitred / Stopped Ends Etc Complete All As Specified And As Directed. 102 M&L For Rendering 15 Mm Thick On Fair Faces Of Brick Work Or Concrete Surfaces In Cement Mortar 1:4 And Rendering Is To Be Finished Fair And Even Without Using Extra Cement Complete All As Specified And As Directed. 103 Schedule A Part ( E / M ) Portion :- M & L For Point Wiring With 1.5 Sqmm Multistranded Copper Conductor Wire With Unsheathed, Frls Grade Pvc Insulated, Single Core With Earth Continuity Conductor Of 1.5 Sqmm Frls Grade Pvc Insulated Multistranded Copper Conductor And Including Rigid Pvc Conduit Concealedof Suitable Size But Not Less Than 20Mm Dia. And Allaccessories Fixed To The Surface Of The Roof / Walls Or In Chases Etc. Including Terminal Boxes Made Out Of Ms Sheet Of Thickness Should Be Not Lessthan 1.2Mm Thickfor Fixing Of Switches, Fan Regulators Socket Outlet Etc Along-With 3 Mm Thick Top Laminated Bakelite Sheet For Housing Switches, Etc Complete All As Specified And As Directed For The Following :- 104 ( A ) One Light Point Controlled By One Switch 105 ( B ) One Ceiling / Exhaust Fan Point Controlled By One Switch 106 ( C ) One Three Pin Socket 5 Amps Independentwith 1.5 Sq Mm Coppper Conductor Cable. 107 ( D ) One Three Pin Socket 5 Amps Plug Point On Same The Board 108 Description All As Per Ser Item No 105 Above But With 2.5 Sq Mm Multistranded Copper Wire With 2.5 Sq Mm Multistranded Copper Wire As Earth Continuity Conductor In And Including Pvc Conduit ( Not Less Than 20 Mm ) Complete All As Specified And As Directed For 15 Ampssocket. 109 S&F Switch Piano Type Polycorbonate White 1 Way, 6Amps, 240 Volts Complete All As Specified And As Directed. 110 S&Fceiling Rose, Three Terminal, Pvc / Polycarbonate, Insulated Body, Isi Markedcomplete All As Specified And As Directed. 111 S&F Stepped Typepolycorbonate White Electronic Fan Regulator Flush Type Complete All As Specified And As Directed. 112 S&Fsocket Outlet Polycorbonate White 6 Amps - 2 / 3 Pin Complete All As Specified And As Directed. 113 S&F Switch Socket Combinationpolycorbonate White 2 In 1, 3 Pin, 5Flush Type Universal Complete All As Specified And As Directed. 114 S&Fswitch Socket Combinationpolycorbonate White 2 In 1, 3 Pin, 5 And 15 Amps Flush Type Universal Complete All As Specified And As Directed. 115 S&Fled Light Fitting 1X10 W 220 V Ac Decorative Box Type With Driver, Holder Including Led Tub Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And As Directed. 116 S&Fled Light Fitting 1X20 W 220 V Ac Decorative Box Type With Driver, Holder Including Led Tub Light Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And As Directed. 117 S&F Flush / Surafce Typelight Fittings Of Size 600 Mm X 600 Mm Suitable For 36 Wled Complete With Inbuilt Driversurface Mounted / Recessed Type Slim Box Type Luminaries With Crca Housing White Powder Coatedfinish Suitable To Operate With 230 V Ac, Complete With All Accessories Internally Pre-Wired And Including Connecting Up With Three Core Twisted Flexible Copper Conductor Cable With Cross Sectional Area 1.0 Sqmm After Removing Unserviceable Rusted Fittings Complete All As Specified And As Directed. 118 S&F Of Mcb Db Spn 4 Way With Copper Bus Bar & Neutral Link Double Door Type To Be Fixed In The Wall Including Connections And Making Good The Disturbed Surface Of Wall To Perfectly Match With The Exsting Wall Complete All As Specified And As Directed. 119 S&F Of Mccb Db Tp 4 Way Triple Pole Vertical Type 415 Volts 50 Hz Ac Supply Including Suitable Provisionfor 4 Pole Mccb Incomer, Fixed To The Existing Wall ( Concealed / Surface ) And Making Good The Disturbed Surface Wall With The Exsting Wall Complete All As Specified And As Directed. 120 S&F Mcb Spn 6 To 32 Amps, 10 Ka Rupturing Capacity Complete All As Specified And As Directed. 121 S&F Fix Mcb Sp 6 To 32 A 10 Ka Rupturing Capacity Complete All As Specified And As Directed. 122 S&F Mccb 4 Pole 63 Amps, 16 Ka Breaking Capacity, 415 Volts 3-Phase Supply Complete All As Specified And Directed. 123 M&L For Earthing Complete With Gi Earth Plate Electrode Of Size 600 Mm X 600 Mm X 6.6 Mm Thick Buried Directly In Ground With Earth Pit Not Less Than 2.25 Meter Deep Below Ground Level With Top Edge Of Plate Not Less Than 1.5 Meter Below Normal Ground Level Connected To Gi Wire 4 Mm Dia Earth Lead By Means Of Nuts, Bolts, Check Nuts, Washers Of Galvanised Iron As Steel, Protected By Galvanized Iron Pipe 40Mm Bore ( Medium Grade ) Allas Directed Including Cement Concrete ( 1:3:6 ) Type C-1 Earth Pit With Precast Rcc ( 1:1.5:3 ) Type A-1 Cover Slab Of Size 42 X 42 X10cm Thick Reinforced With 8Mm Dia Tmt Bars @ 15 Cm C / C Both Ways With 10Mm Dia Mild Steel Round Bar Of 30 Cm Long, Bent To Shape As Lifting Handle, Funnel, Wire Mesh, 20 Mm Bore Galvanized Iron Pipe ( Medium Grade ) For Watering, Earth Testing Point, Charcoal Or Coke And Salt In Alternate Layers With Necessary Earth Work In Soft / Loose Soil Complete All As Shown In Electrical Plate No 3 Of Ssr Part I Including Testing On Completion All Complete As Specified And As Directed . ( Gi Wire Upto 7.5 M Including Testing Consider In This Item ) . 124 Supply & Fixing Exhaust Fan Non Metallic With Louvers 250 Mm Sweep Single Phase 240V Ac 50 Hz And Making Necessary Opening On Stone / Brick Masonary Wall Of Suitable Size Finishing It Properly And Making Good With Matching Colours With The Surrounding Provision Of Cable 3 Core Of Size 0.5 Sqmm From Ceiling Rose To Fan Complete All As Specified And Directed. 125 Supply & Fixceiling Fan Complete With All Accessories 230 V, 1200 Mm Sweep Bee 3 Star Ratedcomplete All As Specifed And Directed By Engineer-In-Charge. 126 M & L Sand Covering / Cushioning For Underground Cable Protection Complete All As Specified Anddirected . 127 M&Lfor Burntbricks Sub ClassB Laid Perpendicularover & Cushioning For Cable Protection Complete All As Specified And Asdirected . 128 M & L Forconnecting And Testing Forxlpe Insulated, Armoured Heavy Duty Electric Cable With Aluminum Conductor , 1100 Volts Grade, Cross-Sectional Area 10 Sqmm And 2Core Laid In Trenches Includingaluminium Lugs As Required For Connection Complete All As Specified And Directed . 129 Material And Labour For 25 Mm Dia Galvanised Steel ( Gl ) Tubing Medium Grade With Screwed Socket Joints, Together With All Tube Fittings ( Such As Bends, Elbows, Tees, Shortpieces, Connectors, Back- Nuts, Diminishing Pieces, Caps, Plugs And Unions, Etc. ) And Laying In Trenches, Etc., Also For Cutting, Screwing And Waste And For Making Forged Bends On Piping As Required. Connectors Shall Be Inserted, Where Required Or Directed. The Rates Also Include Cutting Through Walls, Floors, Etc. And Their Making Good For 25 Mm Pipe Bore Size Complete All As Specified And Directed . 130 Material And Labour For 15 Mm Dia Galvanised Steel ( Gl ) Tubing Medium Grade With Screwed Socket Joints, Together With All Tube Fittings ( Such As Bends, Elbows, Tees, Shortpieces, Connectors, Back- Nuts, Diminishing Pieces, Caps, Plugs And Unions, Etc. ) And Laying In Trenches, Etc., Also For Cutting, Screwingand For Making Forged Bends On Piping As Required. Connectors Shall Be Inserted, Where Required Or Directed. The Rates Also Include Cutting Through Walls, Floors, Etc. And Their Making Good For 15 Mm Pipe Bore Size Complete All As Specified And Directed . 131 Supply And Fix Gun Metal Globe / Gate Valve With Iron Wheel Head, Screwed With Ends Foriron Pipe Isi Marked Of Size 15 Mmcomplete All As Specified And Directed . 132 M&L For Cutting / Bore The Exisiting Pipe Line Of Any Size ( Gi / Ci ) Incliding All Fitinings And Accessories For Taking The Water Supply Connection Complete All As Directed.

Key Value

Document Fees
INR 500 /-
EMD
INR 76000.0 /-
Tender Value
INR 38 Lakhs /-

BOQ Items

Name of Work : - PROVISION OF TRAINING EQUIPMENT AND ADDITION / ALTERATION TO ALLIED TRAINING INFRASTRUCTURE AT AFAHYDERABAD
Sl. No. Item Description
1SCHEDULE "A" PART -I (B/R PORTION) :-Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in hard / dense soil complete all as specified and as directed.
2Removing excavated material / soil to a distance exc 250 mtr and not exc 500 mtr anddepositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and as directed.
3Excavating in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depthfor foundations, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exc 10 sq m on plan and n exc 1.5 mtr in depth and getting out in hard / dense Soil complete all as specified and as directed.
4M&L for excavation in trenches not exc 1.5 mtr widthand not exc 1.5 mtr in depth and getting outin any type of soil complete all as specified and as directed.
5Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and as directed.
6Removing excavated soil not exc. 50 mtr and depositing where directed at a level not exc. 1.5 mtr above the starting point complete all as specified and as directed.
7M& L for Plain Cement Concrete PCC1:4:8 type D-2 mix(using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and as directed.
8M&L for RCC M- 25as in Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete complete all as specified and as directed.
9M&L for RCC M-25as in Columns, pillars, piers, posts and struts complete all as specified and as directed.
10M&L for RCC M-25as in Beams, cantilevers, bressummers, lintels over 1.5 mtr span complete all as specified and as directed.
11M&L for RCC M-25Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
12M&L for RCC M-25as in Chajjas etc complete all as specified and as directed.
13M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter surfaces complete all as specified and as directed.
14M&L for Formwork to sides of pillars, posts, struts, piers, columns and stanchionscomplete all as specified and as directed.
15M&L for Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams,etc.complete all as specified and as directed.
16M&L for Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200 mm thick (horizontal or sloping) complete all asspecified and as directed.
17M&L for Formwork tochajjas, troughs and similar items including edges for rough finished surfaces of concrete flat complete all as specified and as directed.
18M& L for Pre-cast cement concrete block masonry with(1:3:6) type C-1 mix using 20 mm graded stone aggregate solid blocks, exc. 10 cm in width and setting in cement mortar 1:6,complete all as specified and as directed.
19M&L for Providing precast cement concrete with PCC 1:3:6 type C- 1 mix using 20 mm graded stone aggregate solid building blocks or slabs not exc 10 cm thick (with plain or interlocking joints as directed)set in mortar 1:4asin walls complete all as specified and as directed.
20M&L for Mild steelTMT bars 10 mm dia and over cut to length bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
21M&L for Mild steelTMT bars 6 mm to 8 mm dia cut to length bent to shape required including crancking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia complete all as specified and as directed.
22Description all as per Ser Item No 20 abovebut as in stirrups, spacers and binders etccomplete all as specified and as directed.
23M & L for Rendering 10 mm thick on fair faces of brick work or concrete wall surfaces in CM 1:6 and rendering is to befinished even & smooth without using extra cement complete all as specified and as directed.
24M & L for Rendering 5 mm thick on fair faces of brick work or concrete ceiling surfaces in CM 1:3 finished even & smooth without using extra cement complete all as specified and as directed.
25M & L for Rendering 15 mm thick on fair faces of brick work or concrete surfaces in CM 1:4 finished even & smooth without using extra cement with using WPCcomplete all as specified and as directed. (NOTE :- WPC shall be measured and paid separately).
26M & L for Rendering 10 mm thick on concrete surfaces of roof in CM 1:3and rendering is to befinished even & smooth without using extra cement with using WPC complete all as specified and as directed. (NOTE :- WPC shall be measured and paid separately)
27Supply Only of Integral waterproofing compound of approved makes complete all as specified and as directed.
28M&L for preparation of new plastered surfaces of walls and applying two coats of Oil bound distemperover a coat of primer complete all as specified and as directed.
29M&L for applying two coats of Oil bound distemper on ceilings including reparation of new plastered surfaces over a coat of primer complete all as specified and as directed.
30M&L for Preparing newly plastered surfaces of walls and applying two coats of cement based paint over a coat of primer complete all as specified and as directed.
31M&L for Hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
32M& L for 100 mm thick Plain Cement concrete1:4:8 type D-2 mix(using 40 mm graded stone aggregate) as in sub base flooring etccomplete all as specified and as directed.
33M&L 25 mm thick plain Cementconcrete1:2:4 type B-1 mix(using 20 mm graded stone aggregate) as in floor finish concrete complete all as specified and as directed.
34M & Lfor coloured Non-skid ceramic tiles(square/rectangular) 7 to 8mm thick in floors, area of each tile exc.0.11 sqm but n.exc 0.18 sqm, set and jointed in neat cement slurry and pointed in white cement mixed with matching pigment over and including 20 mm thick screed bed in CM 1:6 all complete all as specified and as directed.
35M&L for Glazed ceramic tiles in vertical surfaces 350 x 250 x 7 mm / 450 X 350 X 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick screed plasterin cement mortar 1:4 to receive wall tiles etc complete all as specified and as directed.
36S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colourPVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and as directed.
37S& F Solid PVC Door Frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and as directed.
38M&L for Anodised aluminium window andventilator shutters, top hung type without sash bars, aluminium sections weighing 0.55 kg / m including necessary joining cleats, glazing clips,rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150 mm long (1 No.). hinges type B-21 100mm long (2 Nos.) suitable handle (1no.) complete all as specified and as directed.
39S&F 3.0 mm thick Figured glass, pin head type and glazing with aluminium beadingin squares n.exc 0.5 sq mtr in each pane complete all as specified and as directed.
40S&F 100 mm stainless steelbutt hinges, cold rolled medium weightcomplete all as specified and as directed.
41S&F100 mm Aluminum anodised barrel tower bolts of extruded sectioncomplete all as specified and as directed.
42S&F 100 mm extruded aluminium anodised alloy handles fabricated typecomplete all as specified and as directed.
43S&F250 mm aluminum alloy anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminum alloycomplete all as specified and as directed.
44S&F vitreous china wash down water closet (pedestal pattern) white (excluding fixing bolts, flushing cistern ) with plastic water closet seat including fixing of flush pipe to pedestal pan including all joints complete all as specified and as directed.
45S&F 10 ltr capacity PVC valve less, syphonic action type flushing cistern, low level, white, with inlet, ball valve, float and handle including brackets complete all as specified and as directed.
46S&FVitreous China wash basin, white, oval type, size 550 mm x 440 mm excluding taps, waste, chain and plug and porcelain stopperoval type but including brackets CP waste coupling (flat back or angle back type) any size and 32 mm dia waste pipe, including cutting for and pinning in ends of brackets or erecting stand including waste pipe complete all as specified and as directed.
47S&F 15 mm diaBib taps, cast copper alloy with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule andfixed to 15 mm bore pipecomplete all as specified and as directed.
48S&F 15 mm borePillar taps, cast copper alloy fancy type, with capstan heads, chromium plated, screwed down high pressure, with or without lettered "Hot" or "Cold" with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and as directed.
49S&F of stop valves / angle valves15 mm dia cast copper alloyfancy type CP screweddown high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions, of 15 mm boreetc completeall as specified and as directed
50S&F of Vitreous China urinals, half stall bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) complete all as specified and as directed.
51S & FPVC connections 15 mm size with PTMT nuts of length 450 mmcomplete all as specified and as directed.
52S&FPVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and as directed.
53S&F 600 mm x 450 mmmirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and as directed.
54S&F of 15 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors etc including taking down old complete all as specified and as directed.
55S&F of 20 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors etc including taking down old complete all as specified and as directed.
56S&F of 25 mm bore steel tubing medium grade galvanised with all fittings and fixed complete to walls and ceilings or laid in floors etc including taking down old complete all as specified and as directed.
57S & F PVC (SWR) pipes of 110 mm dia single socketed in any length with rubber ring joints fixed to walls / floors including connections complete all as specified and as directed
58S & F PVC (SWR) pipes of 75 mm dia single socketed in any length with rubber ring joints fixed to walls / floor including connectionscomplete all as specified and as directed
59S&F of 110 mm bore PVC (SWR) bends any radiuscomplete all as specified and as directed.
60S&F of 75 mm bore PVC (SWR) bends any radius complete all as specified and as directed.
61S&F PVC 110 mm bore (SWR) junction single, (Single T) equal or unequal complete all as specified and as directed.
62S&F PVC (SWR) vent cowl 110 mm bore complete all as specified and as directed.
63M& L for 75 mm thickPlain Cement concrete1:3:6 type C-1 mix (using 20 mm graded stone aggregate) as in plinth protection laid in alternate bays not exceeding 2 Sqm each and finished fair on top without using extra cement. 6mm wide joints shall be provided throughout the thickness of plinth protection in concrete bays. All joints in bays of concrete, shall be filled with mastic filling comprising of one part of heated bitumen Vg-30 grade and 3 parts of sand (all by weight). complete all as specified and as directed.
64Excavating in post holes (or similar holes) each n exc 0.5 cum,getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50m and making good surface in hard / dense soil complete all as specified and as directed.
65M&L for Plain cement concrete 1:2:4, Type B-2mix using 40 mm graded stone aggregate as in foundations, filling and mass concrete etc complete all as specified and as directed.
66M&L for PCC1:2:4, type B-0 mixusing 12.5 mm graded stone aggregate as in copings, kerbs and the like including weathering, slightly rounded for chamfered angles and threading, including necessary formworkcomplete all as specified and as directed.
67Dismantling wrought iron or MS work of any description and in any position complete all as specified and as directed.
68S&Fof Steel work as in tubular posts, trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to IS 1161-1979 grade St.-240 complete all as specified and as directed.
69M&L for MS plates Fe 410 Gd E250 in trusses (framed), etc connecting with bolts/welding as base plates/connecting platesetc complete all as specified and as directed.
70M&L for Bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required; hooks (stay), heavy, for large gates; hook and pintle hinges; large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles conforming to Fe 290 Gde E-165 complete all as specified and as directed.
71S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut n exc 5 cm long dia of neck 11 to 15 mm complete all as specified and as directed.
72S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nutexc 30 cm long dia of neck exc 12 n exc 20 mm complete all as specified and as directed.
73Dismantlingplain or corrugated steel sheeting, any gauge thickness including roof coverings complete all as specified and as directed.
74S&F 6 mm thick multiwall polycarbonate sheet make as approved by GE with side laps using "H" channels including taps , adhesive etc as per manufacturers instructions andfixed with purlin member supports and stainless steel self driven screws and washers in roof etc complete all as specified and as directed.
75S&F 2 mm thick Diamond polycarbonate sheet fixed into the roof / wall etc and fixing with self driven screws complete all as specified and as directed.
76M&L for preparation of new steel surfaces of any description and applyingtwo coats of synthetic enamel paint over a coat of red oxide zinc crome primer on surfaces over 10 cm in width or girth, not otherwise described complete all as specified and as directed.
77M&L for preparation of old steel surfaces and applyingone coat of synthetic enamel paint on surfaces of any description,over 10 cm in width or girth, not otherwise described complete all as specified and as directed.
78M&L for framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanksand similar work conforming to Fe Fe 290 Gde E-165 complete all as specified and as directed.
79S&F Pre painted galvalume aluminium zinc coating GI based corrugated sheet 0.5 mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed.
80S&F Pre painted galvalume aluminium zinc coating GI based plain sheet 0.5 mm thick of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall with self tapping screws complete all as specified and as directed.
81M&L for 75 mm thick PCC 1:4:8 type D-2 mix(using 40 mm graded stone aggregate)as in floor , sub base etc complete all as specified and as directed.
82M&Lfor pressed precast concrete interlocking paver block any shape and size conforming to IS 155658 - 2006 of 60 mm thickness M-35 grade with grey cement and pigment and including required sand cushing, sealing the edgescomplete all as specified and as directed.
83M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces in CM 1:4and rendering is to be finishedeven and smooth without using extra cement complete all as specified and as directed
84M&L for preparing old wall surfaces and applying one coat of cement base paintcomplete all as specified and as directed.
85M&L for 100 mm thick plain Cementconcrete1:2:4 type B-1 mix (20 mm graded stone aggregate) as in floor finish concrete etc complete all as specified and as directed.
86M&L for Forming Contraction (Dummy) joints 65 mm deep x 10 mm wide, filled with sealing compound Grade "A" complete all as specified and as directed.
87M&L for Providing precast reinforced cement concrete1:2:4 type B-1 mix(using 20 mm graded stone aggregate) as in cover slabs icluding necessary form work complete all as specified and as directed. Note :- Reinforment steel shall be measured and paid separately
88Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc laid, bedded and pointed in any mortar complete all as specified and as directed.
89M&L for roughening surfaces of old concrete floor by picking, sweeping, clean and washing down with water to remove dust, etc. complete all as specified and as directed.
90M&L for screed bed or bedding layer of mortar 20 mm thick for laying floor finishesin CM (1:4) etccomplete all as specified and as directed.
91M&L for Machine cut kota stone slab flooring 20-25 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and as directed.
92M&L for 20 mm thick white marble (Makarana white) tiles machine cut asin flooring laid over cement scrred and jointed with grey cement slurryin between kota stone flooring as boarders incuding cutting and polishing complete all as specified and as directed.
93Taking down cement plaster from walls built in cement mortar, etc. including raking out joints, hacking for key, scrubbing down with water, etc. to receive plaster.(for dado) complete all as specified and as directed.
94Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
95M&L for Providing and fixing in true horizontallevel false ceiling grid system manufactured by M/S ARMSTRONG WORLD INDUSTRIES US/UK using hot dipped galvanised steel section exposed surface chemically cleaned capping, prefinished in baked polyester paint, main Tee of size 3000 x 32 x 15 mm at every 1200 c/c, max and 1200 mm cross Tee of size 1200 x 32 x 15 mm at every 600 mm c/c, max and 600mm cross Tee of size600x32x15mmat every 120 mm c/c max and 3000x19x19mm wall angle all around the wall to form grid size of 600x600mm and suspending the grid using 2 mm pro-straightened GI wire and 6 mm nylon raw plug at every 1299 mm intervals at the main tee and laying ARMSTRONG ULTIMA MICRO LOOK manufacturedby Armstrong World Industries complete all as specified and as directed.
96M&L for preparation of old wooden surfaces and applyingone coat of synthetic enamel paint on surfaces of any description,over 10 cm in width or girth, not otherwise described complete all as specified and as directed.
97M&L for Plain Cement Concrete1:2:4 type B-1 mix(using 20 mm graded granite stone aggregate) as in benching of man holes including forming centre channels half round or 1/4 section complete all as specified and as directed.
98M &L for PCC 1:4:8 type D-2mix (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes incluyding packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and as directed.
99M&L for pre-cast RCC slabs as in manhole covers in 1:2:4 type B1 using 20 mm graded stone aggregate, set in cement mortar (1:4) including use and waste of form work complete all as speciied and as directed.
100M & Lfor 150 mm dia reinforced concrete pipes of class NP-3 with one collar per length of pipe complete all as specified and as directed.
101M&L for Extra forming forfair finished drain or channels of 30 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred / stopped ends etc complete all as specified and as directed.
102M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and rendering is to be finished fair and even without using extra cement complete all as specified and as directed.
103SCHEDULE "A" PART (E/M) PORTION :- M & L for Point wiring with 1.5 Sqmm multistranded copper conductor wire with unsheathed, FRLS grade PVC insulated, single core with earth continuity conductor of 1.5 sqmm FRLS grade PVC insulated multistranded copper conductor and including rigid PVC conduit concealedof suitable size but not less than 20mm dia. and allaccessories fixed to the surface of the roof/ walls or in chases etc. including terminal boxes made out of MS sheet of thickness should be not lessthan 1.2mm thickfor fixing of switches, fan regulators socket outlet etc along-with 3 mm thick top laminated bakelite sheet for housing switches, etc complete all as specified and as directed for the following :-
104(a) One light point controlled by one switch
105(b) One ceiling / Exhaust fan point controlled by one switch
106(c) One three pin socket 5 Amps independentwith 1.5 sq mm coppper conductor cable.
107(d) One three pin socket 5 Amps plug point on same the board
108Description all as per Ser item No 105 above but with 2.5 sq mm multistranded copper wire with 2.5 Sq mm multistranded copper wire as earth continuity conductor in and including PVC conduit (not less than 20 mm) complete all as specified and as directed for 15 Ampssocket.
109S&F Switch Piano type polycorbonate white 1 way, 6Amps,240 Volts complete all as specified and as directed.
110S&Fceiling rose, three terminal, PVC / polycarbonate, insulated body, ISI markedcomplete all as specified and as directed.
111S&F stepped typepolycorbonate white electronic fan regulator flush type complete all as specified and as directed.
112S&FSocket outlet polycorbonate white 6 Amps - 2 / 3 pin complete all as specified and as directed.
113S&F Switch socket combinationpolycorbonate white 2 in 1, 3 pin, 5flush type universal complete all as specified and as directed.
114S&FSwitch socket combinationpolycorbonate white 2 in 1, 3 pin, 5 and 15 Amps flush type universal complete all as specified and as directed.
115S&FLED light fitting 1x10 W 220 V AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
116S&FLED light fitting 1x20 W 220 V AC decorative box type with driver, holder including LED tub light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
117S&F flush / surafce typelight fittings of size 600 mm x 600 mm suitable for 36 WLED complete with inbuilt driversurface mounted/recessed type slim box type luminaries with CRCA housing white powder coatedfinish suitable to operate with 230 V AC, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable with cross sectional area 1.0 Sqmm after removing unserviceable rusted fittings complete all as specified and as directed.
118S&F of MCB DB SPN 4 way with copper bus bar & neutral link double door type to be fixed in the wall including connections and making good the disturbed surface of wall to perfectly match with the exsting wall complete all as specified and as directed.
119S&F of MCCB DB TP 4 way triple pole vertical type 415 volts 50 Hz AC supply including suitable provisionfor 4 pole MCCB incomer, fixed to the existing wall (concealed/surface) and making good the disturbed surface wall with the exsting wall complete all as specified and as directed.
120S&F MCB SPN 6 to 32 Amps, 10 KA rupturing capacity complete all as specified and as directed.
121S&F Fix MCB SP 6 to 32 A 10 KA rupturing capacity complete all as specified and as directed.
122S&F MCCB 4 pole 63 Amps, 16 KA breaking capacity, 415 Volts 3-phase supply complete all as specified and directed.
123M&L for Earthing complete with GI earth plate electrode of size 600 mm x 600 mm x 6.6 mm thick buried directly in ground with earth pit not less than 2.25 meter deep below ground level with top edge of plate not less than 1.5 meter below normal ground level connected to GI wire 4 mm dia earth lead by means of nuts, bolts, check nuts, washers of galvanised iron as steel,protected by galvanized iron pipe 40mm bore (Medium grade) allas directed including cement concrete (1:3:6) type C-1 earth pit with precast RCC (1:1.5:3) type A-1 cover slab of size 42 x 42 x10cm thick reinforced with 8mm dia TMT bars @ 15 cm c/c both ways with 10mm dia mild steel round bar of 30 cm long, bent to shape as lifting handle, funnel,wire mesh, 20 mm bore galvanized iron pipe (medium grade) for watering, earth testing point, charcoal or coke and salt in alternate layers with necessary earth work in soft/loose soil complete all as shown in electrical plate No 3 of SSR Part I including testing on completion all complete as specified and as directed .( GI wire upto 7.5 m including testing consider in this item).
124Supply & Fixing exhaust fan non metallic with louvers 250 mm sweep single phase 240V AC 50 Hz and making necessary opening on stone/brick masonary wall of suitable size finishing it properly and making good with matching colours with the surrounding provision of cable 3 core of size 0.5 Sqmm from ceiling rose to fan complete all as specified and directed.
125Supply & fixceiling fan complete with all accessories 230 V, 1200 mm sweep BEE 3 star ratedcomplete all as specifed and directed by Engineer-in-Charge.
126M & L Sand covering /cushioning for underground cable protection complete all as specified anddirected .
127M&Lfor burntbricks sub class"B" laid perpendicularover & cushioning for cable protection complete all as specified and asdirected .
128M & L forconnecting and testing forXLPE insulated, armoured heavy duty electric cable with aluminum conductor ,1100 Volts grade,cross-sectional area 10 Sqmm and 2core laid in trenches includingaluminium lugs as required for connection complete all as specified and directed .
129Material and labour for 25 mm dia galvanised steel (Gl) tubing medium grade with screwed socket joints, together with all tube fittings (such as bends, elbows, tees, shortpieces, connectors, back- nuts, diminishing pieces, caps, plugs and unions, etc.) and laying in trenches, etc., also for cutting, screwing and waste and for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good for 25 mm pipe bore size complete all as specified and directed .
130Material and labour for 15 mm dia galvanised steel (Gl) tubing medium grade with screwed socket joints, together with all tube fittings (such as bends, elbows, tees, shortpieces, connectors, back- nuts, diminishing pieces, caps, plugs and unions, etc.) and laying in trenches, etc., also for cutting, screwingand for making forged bends on piping as required. Connectors shall be inserted, where required or directed. The rates also include cutting through walls, floors, etc. and their making good for 15 mm pipe bore size complete all as specified and directed .
131Supply and fix Gun metal globe / gate valve with iron wheel head, screwed with ends foriron pipe ISI marked of size 15 mmcomplete all as specified and directed .
132M&L for Cutting / Bore the exisiting pipe line of any size ( GI / CI )incliding all fitinings and accessories for taking the Water supply connection complete all as directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail