Textiles Statutory Bodies & Commissions/Committees Closing in 0 days TDR #34163209

Maintenance Of Existing Work Shed At Vattiyoorkkavu In Thiruvananthapuram Dist

Issued by Statutory Bodies & Commissions/Committees · thiruvananthapuram, Kerala
Tender Value
Ref. Documents
Estimated cost
Bid Submission
13 Oct 2022
0 days left
EMD
26500
Bank guarantee accepted
Document Fee
2300
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
thiruvananthapuram → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Maintenance Of Existing Work Shed At Vattiyoorkkavu In Thiruvananthapuram Dist

BOQ

Name of Work:Maintenance of existing Workshed at Vattiyoorkavu, Thiruvananthapuram District
Sl. No. Item Description
1APPENDIX-A
2Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50m outside the periphery of the area cleared.(D S R2018 ,2.31.)
3Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - inChargeNominal concrete 1:4:8 or leaner mix (i/c equivalent design Mix) ( D S R2018 ,15.2.2. )
4Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. In cement mortar ( D S R2018 ,15.7.4 )
5Dismantling doors, windows and clerestory windows (steel or wood) shutter including Chowkhats, architrave, hold fasts etc complete and stacking within 50 metres leadOf area 3 sq. metres and below( D S R2018,15.12.1.)
6Dismantling wood work in frames, trusses, purlins and rafters up to 10 metres span and 5 metres height including stacking the material within 50 metres lead. Of sectional area 40 square centimetres and above (2018 D S R ,15.14.1.)
7Dismantling steel work in built up sections in angles, tees, flats and channels including all guzzet plates, bolts nuts, cutting rivets, welding, etc. including dismembering and stacking within 50 metres lead( 2018D S R,15.18.)
8Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos sheet ( D S R2018, 15.28.2)
9Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.(D S R 2018,15.56 )
10Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size).( 2018D S R, 4.1.5)
11Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) ( 2018D S R 4.1.10 )
12Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete(ObservedDataBuildings 50.6.2.2.)
1312 mm cement plaster of mix : 1:4 (1 cement: 4coarse sand)(D S R2018,13.4.1.)
1412 mm cement plaster finished with a floating coat of neat cementof mix : 1:3 (1 cement: 3 fine sand) (D S R2018 , 13.7.1)
15Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. meters and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50metres lead : With cement mortar 1:4 (1 cement : 4coursesand). ( D S R14.1.2.)
16Applying one coat of water thinnable cement primer of approved brandand manufacture on wall surface :Water thinnable cement primer (2018D S R, 13.43.1 )
17Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On steel work ( D S R2018 , 13.52.1)
18Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work.( 2018D S R ,13.61.1 . )
19Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete .( 2018 D S R ,13.88 )
20Wall painting with plastic emulsion paint of approved brand and manufactureto give an even shade : One or more coats on old work(2018 D S R 13.98.1)
21Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work. ( 2018D S R,13.99.1 )
22Finishing walls with Acrylic Smooth exterior paint of required shade:Old work (Two or more coats applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface (2018D S R13.111.1)
23Providing and fixing Ist quality ceramic glazed wall tiles conforming toIS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of stepsand dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm,including pointing in white cement mixed with pigment of matching shadecomplete.(2018D S R ,8.31)
24Providing and laying Ceramic glazed floor tiles of size 300x300 mm(thickness to be specified by the manufacturer) of 1st quality conformingto IS : 15622 of approved make in colours such as White, Ivory, Grey,Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement :4 Coarse sand), jointing with grey cement slurry @ 3.3kg/sqm including pointing the joints with white cement and matching pigmentetc., complete. (DS R 2018,11.37 )
25Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6mm angle iron and 3mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M. S. ANGLES 40X40X6 mm for diagonal braces and central cross piece.( D S R10.5.2 )
26Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.Hot finished welded type tubes ( D S R10.16.1)
27Providing and fixing angle iron frames for doors, windows andventilators of mild steel Angle sections of size 35x35 x5 mm, jointsmitred and welded by angle iron 35x35x5 mm or 35x 5 mm flatpieces to the existing T-iron frame or to the wall with dash fastener,including fixing of necessary butt hinges and screws and applyinga priming coat of approved steel primer, all complete as per thedirection of Engineer-In-charge. ( D S R10.31)
28Fixing chowkhats in existing opening including embedding chowkhats in floors or walls, cutting masonry for cement concrete blocks of size 15 x 10x 10 cm with cement concrete 1 : 3 : 6 ( 1 Cement :3 Course Sand : 6 Graded Stone Aggregate 20 mm nominal size ), Painting two coats of approved wood preservative to sides of Chowkhats and making good the damages to walls and floors as required complete, includingdisposal of the rubbish to the dumping ground within 50 m lead Door chowkhats( D S R 14.2.1.)
29Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch ofcorrugation as approved by Engineer-in-charge) 0.35 mm (+0.05%), total coatedthickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side. of the sheet and polyester top coat 15-18 microns.Sheet should have protective guard film of 25 microns minimum to avoid scratchesduring transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws ofsize (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical orcurved surfaces, excluding the cost of purlins, rafters and trusses and including cutting tosize and shape wherever required.(OD 51.20)
30Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+ 0.05 %) total coated thickness, Zinc coating 120 gsm as per IS: 277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm). ( D S R 12.51.1 )
31Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance 0.1 mm), with wall thickness 2.0mm (0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer\"s specification and direction of Engineer-in-charge Extruded section profile size 48x40 mm ( D S R9.117.1)
32Providing and fixing to Door Frame 24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mmwith inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm wall thickness. The lock rail made up of \"H\" section, a uPVC hollow section of size 100x24 mm and 2 mm wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. \"U\" cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer\"s specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter). ( D S R9. 118. 1)
33Providing & fixing Poly carbonate corrugated/Plainsheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shape( OD50.12.2.1.)
34Providing and fixing false ceiling with e board classic tile or equivalent make of size 610x610x4 mm ceiling of approved quality in aluminium frame work with necessary screws etc complete ( aluminium frame work shall be paid separately) ( APPROVEDOBSERVED DATABUILDINGS50.12.5.1 )
35Providing and fixing powder coated aluminium work ( minimum thickness of powder coating 50 micron) consisting of tee /angle sections, of approved make conforming to IS : 733 in frames of false ceiling including aluminium angle cleats with necessary C.P brass/ stainless steel sunk screws, aluminium perimeter angles fixed to wall with stainless steel rawl plugs @ 450 mm centre to centre and fixing the frame work to G.I level adjusting hangers 6 mm dia. with necessary cadmium plated machine screws all complete as per approved architectural drawings and direction of the Engineer-in-Charge ( level adjusting hangers, ceiling cleats and expansion hold fasteners to be paid for separately ). ( D S R21.5 )
36Renewing glass panes, with wooden fillets wherever necessary:Float glass panes of thickness 4 mm (DSR14.6.1 )
37Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap.(D S R17.7.2 )
38Providing and fixing white vitreous china water closet squatting pan (Indian type) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. (17.13.2 . )
39Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete.10 litre capacity - White( D S R17. 18.1 )
40Providing and fixing P.V.C. waste pipe for sink or wash basin includingP.V.C. waste fittings complete.40 mm dia ( D S R17.28.2.2. )
41Providing and fixing PTMT towel rail complete with brackets fixed towooden cleats with CP brass screws with concealed fittingsarrangement of approved quality and colour. 600 mm long towel rail with total length of645mm, 78mm wide and effective height of 88 mm, weighing notless than 190 gms( D S R17.73.2)
42Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :25 mm nominal bore( D S R18.17.1 )
43Providing and fixing PTMT bib cock of approved quality and colour15 mm nominal bore, 122mm long, weighing not less than 99 gms( D S R18.54.2)
44Providing and fixing PTMT grating of approved quality and colour.Rectangular type with openable circular lid150 mm nominal size square 100 mmdiameter of the inner hinged round grating(D S R 18.58.2.1.)
45Providing and fixing PTMT angle stop cock 15 mm nominal bore, weighing not less than 85 gms (D S R18.63)
46Providing and fixing unplasticised P.V.C. connection pipe with PTMTNuts, collar and bush of approved quality and colour-15 mm nominal bore with 45 cm length ( D S R, 18.74.2.)
47Cutting holes up to 30x30 cm in walls including making good thesame: With common burnt clay F.P.S. (non modular) bricks( D S R 2018, 18.76.1 )
48Supplying and fixing Stainless steel soap dish including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge( ODBUILDINGS50.17.1.1)
49Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall( ObservedDataBuildings50.18.7.3.2.)
50Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 20 mm pipe 10 Kgf/ cm2(ObservedDataBuildings50.18.8.2.2.)
51Providing and fixing PVC pipes includes jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 25 mm dia 10KGF/cm2( Observed Data Buildings50.18.9.3.2.)
52Providing and fixing PVC pipes includings joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 32 mm dia10Kgf/cm2 ( ODBUILDINGS50.18.9.4.1.)
53Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.63 mm dia 4 Kgf/cm2 ( ODBUILDINGS50.18.9.7.2)
54Providing and fixing PVC pipes includes joints of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in CHarge. 110 mm dia 4 Kg/cm2( OD50.18.9.9.2. )
55Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10 Kgf/cm2 - External work- Exposed on wall( OD BUILDINGS 50.18.9.14.1.)
56Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 63 mm dia 4 Kgf/cm2- External work - exposed on wall( OD BUILDINGS50.18.9.17.2)
57Providing and fixing PVC pipes including fixing the pipe with clamps/clips at 1.00 m spacing. This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 m dia 4 Kgf/cm2 - External work - Exposed on wall( OD BUILDINGS 50.18.9.19.2)
58Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Elbow( OD50.18.9.20.1 )
59Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -63 dia 45 degree Elbow ( OD50.18.9.20.2. )
60Providing and fixing PVC moulded fittings /accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Door Elbow( OD50.18.9.20.3 )
61Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee ( Observed Data Buildings50.18.9.20.5.)
62ProvidingandfixingPVCmoulded fittings/accessoriesforRigidPVC pipes, including jointing with PVC solvent cement -63x63x63 mm dia Door Tee ( Observed DataBuildings50.18.9.20.6.)
63Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia vent cowl(ObservedDataBuildings50.18.9.20.7.)
64Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow(ObservedDataBuildings50.18.9.22.1. )
65Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia45 \"Elbow(ObservedDataBuildings50.18.9.22.2. )
66Providing and fixingPVC moulded fittings /accessoriesforRigidPVC pipes ,including jointingwithPVC solvent cement-110 mmdiaDoorElbow (ObservedDataBuildings50.18.9.22.3.)
67Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia tee(ObservedDataBuildings50.18.9.22.5.)
68Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm diaDoorTee(ObservedData Buildings50.18.9.22.6)
69Providing andfixingPVCmoulded fittings/accessoriesfor Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia Vent cowl( ObservedDataBuildings 50.18.9.22.8)
70Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes,including jointing with PVC solvent cement - 110 mm dia Socket/ coupling( OD .50.18.9.22.11)
71SupplyandFixingMirrorof GoodQuality ( 600 x 450 mm )
72Supply and Fixing P V C Floor Trap 110 mm with Necessary cutting of Concrete or Masonry and making Good the Same
73Constructing brick masonry chamber for underground C.I. inspectionchamber and bends with bricks in cement mortar 1:4 (1 cement : 4coarse sand) C.I. cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover with frame to be not less than 38kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. topslab with 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stoneaggregate 20 mm nominal size), foundation concrete 1:5:10 (1cement : 5 coarse sand (Zone III) : 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar1:3 (1 cement : 3 coarse sand), finished smooth with a floating coatof neat cement on walls and bed concrete etc. complete as perstandard design: Inside dimensions 455x610 mm and 45 cm deep for singlepipe line :With common burnt clay F.P.S. (non modular)bricks of class designation 7.5( D S R19.30.1.1.)
74Engaging Labour For Cleaning works / Repair WorksBeldar(D S R0115)
75Engaging Labour For Maintenance works / Repair WorksFitterGr II(D S R0116)
76Engaging Labour For Maintenance works / Repair Works ELECTRITIAN
77Engaging Labour For Cleaning works / Repair WorksCarpenter ( D S R 0112)
78Engaging Labour For Maintenance works / Repair WorksPlumber
79Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.( D S RELECTRICAL1.10.1)
80Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 MM( DSRELECTRICAL 1.21.1)
81Supplying and fixing PVC batten/ angle holder including connection etc. as required. ( D S RELECTRICAL1.58)
82SUPPLY AND FIXING 12 W LED LAMP ( BULB ) OF APPROVED BRAND ( CROMPTON, BAJAJ, ORIENT OR Equivalent )
83Supply and Fixing 9 W LED LAMP ( BULB ) Of Approved Brand ( CCROMPTON, BAJAJ, ORIENT OR EQUIVALENT
84SUPPLY AND FIXING 250 MM EXHAUST FAN WITH NECESSARY FITTINGSOFAPPROVEDBRAND
85SUPPLY AND FIXING 1200 MM BATTEN LED LIGHT 20 WATTS WITH ALL NECESSARY FITTINGS (od15443/2021_2022)
86Supply and installation of suitable size MS belt type fan clamp fabricated from flat iron 40 x 6 mm, 150mm long x 2 Nos with M.S. rod bent to shape, neatly painted with 2 coats of enamel paint over a coat of red oxide primer as per IS 732 as required.(ODELECTRICALS90.4.2)
87Supply, conveyance, installation, testing and commissioning of ceiling fans of the following sizes using standard accessories excluding resistance type regulator, wiring the down rod with 16/0.20mm PVC insulated and PVC sheathed 650/1100V grade 3 core round copper conductor flex wire or with extended original wiring etc. as required.1200mm sweep -5star rated ceiling fan complete with 300mm down rod , canopies, shackeles and blades and resistance type regulator working on 230V/240V single phase A/C( ODELECTRICAL 90.4.5.2.)
88Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm (D S RELECTRICAL1.17.3)
89Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm(D S RELECTRICAL1.17.12)
90Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm( D S RELECTRICAL1.17.21)
91Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 amps switch(D S RELECTRICAL1.24.1)
92Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch( D S RELECTRICAL1.24.3)
93Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet(D S RELECTRICAL1.24.4)
94Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet(D S RELECTRICAL1.24.5 )
95Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. (D S RELECTRICAL1.25)
96Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.(D S RELECTRICAL1.26)
97Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)( D S RELECTRICAL1.27.1)
98Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4Module (125mmX75mm)( D S RELECTRICAL1.27.3)
99Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 12Module (200 MmX150Mm)(D S RELECTRICAL1.27.6)
100Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar,,interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator12 WayDouble Door(DSR 2.3.3.)
101Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SinglePole( D S RELECTRICAL2.10.1)
102Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required (D S RELECTRICAL2.11)
103Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. ( 40Amps)( D S R2.12. 1)
104Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 Amps(D S RELECTRICAL2.14.2.)

AI Tender Summary

OUR REF NO 34163209
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 13-10-2022
Authority
Authority Name Kerala Khadi And Village Industries Board
Work Description Maintenance Of Existing Work Shed At Vattiyoorkkavu In Thiruvananthapuram Dist
Basic Detail
Tender No KB.7494/2022/Engg
Bidding Type Tender
Location
City thiruvananthapuram
State Kerala
Key Dates
Publish Date 29 Sep 2022
Submission Date 13 Oct 2022
Open Date 15 Oct 2022
Finance
Tender Value Ref. Documents
Tender Fee 2300
EMD 26500
Exemption Not Available
Document List
ed17e7fa-bf7d-4210-b2f7-c6306a8ea9ac.html
BOQ_732938.xls
Tendernotice_1.pdf
Tendernotice_2.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 29, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 13, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 15, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

ed17e7fa-bf7d-4210-b2f7-c6306a8ea9ac.html

xls

BOQ_732938.xls

pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders