Construction Of 33Kv Line Carrying 148Mm2aaac Overhead Line With 13Mtr Long Wpb From Dp Near Angul 33 / 11Kv Pss To Nalco Aluminium Park Premises ( Side Gate ) For Route Length Of 7 Km And Supply And Laying Of 33Kv 1C X 400Mm2 Xlpe Ug Cable Pkg-02, angul-Odisha

Orissa Industrial Infrastructure Development Corporation-IDCO has published Construction Of 33Kv Line Carrying 148Mm2aaac Overhead Line With 13Mtr Long Wpb From Dp Near Angul 33 / 11Kv Pss To Nalco Aluminium Park Premises ( Side Gate ) For Route Length Of 7 Km And Supply And Laying Of 33Kv 1C X 400Mm2 Xlpe Ug Cable Pkg-02. Submission Date for this Tender is 28-10-2022. Overhead Line Tenders in angul Odisha. Bidders can get complete Tender details and download the document.




Tender Notice

34152849
Construction Of 33Kv Line Carrying 148Mm2aaac Overhead Line With 13Mtr Long Wpb From Dp Near Angul 33 / 11Kv Pss To Nalco Aluminium Park Premises ( Side Gate ) For Route Length Of 7 Km And Supply And Laying Of 33Kv 1C X 400Mm2 Xlpe Ug Cable Pkg-02
National Competitive Bid
Indian
Odisha
angul
28-10-2022

Tender Details

Construction Of 33Kv Line Carrying 148Mm2aaac Overhead Line With 13Mtr Long Wpb From Dp Near Angul 33 / 11Kv Pss To Nalco Aluminium Park Premises ( Side Gate ) For Route Length Of 7 Km And Supply And Laying Of 33Kv 1C X 400Mm2 Xlpe Ug Cable Pkg-02

Key Value

Document Fees
INR 11800 /-
EMD
Refer document
Tender Value
INR 2.81 Crore /-

BOQ Items

Name of Work: Construction of 33kV line carrying 148mm2 AAAC overhead line with 13mtr long WPB from DP near Angul 33/11kV PSS to NALCO Aluminium Park Premises (Side Gate) for route length of 7 Km and Supply and laying of 33KV 1C x 400mm2 XLPE UG cable (wherever required). (PKG-II) (The bidders are required to Quote their rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed)
Sl. No. Item Description
1PART-A: Construction of 33KV OH line with 13mtr WPB from DP near Angul 33/11KV PSS to Nalco Aluminium Park Premises (side gate) for a route length of 7Ckm.
233KV DP required withou Isolator.
3WPB 160x152 (13Mtr. Long, 30.44KG/Mtr.)
4Top Channel 100 x 50 x 6mm, 9.56 KG/Mtr., each channel length 3 mtr., 2 no"s channel required =( 2x9.56x3)
5Fish Plate 50x6 mm., 2.36 kg/Mtr each 0.280 mtr. length, 6 no"s required = (6x2.36x0.280)
6Double Pole Belting Channel 75 x 40 x 4.8mm.7.14KG/Mtr., each channel length 1.96 Mtr., 5 no"s channel required = (5 x 7.14 x 1.96)
750 x 50 x 6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 3.432 mtr, 4 nos angle required = (4 x 4.5 x 3.432)
8Danger Plate, 2 no"s.
9Back Clamp for danger Plate 25 x 3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no"s = (2x0.59x0.510)
10H.T. Stay clamp, 50x8 mm. flat, 3.14Kg/Mtr., 0.551 Mtr. Length, 2 no"s qty. required ( 1 Pair)
11H.T. Stay set (Complete )
12H.T. Stay Insulator Type-C (2 no"s)
137/8 SWG Stay Wire 15kg /stay
14Gi Pipe Earthing 40mm. 3 Mtr. Long
1550x6mm GI Flat for earthing, 2.36kg/mtr. (2.5 mtr. For mesh iformation and 2.5 mtr. For raising)= 5x2.36
16GI barbed wire anticlimbing device 3 Kg. Per support.
17Back Clamp for anticlimbing device 25 x 3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 8 no"s = (8x0.59x0.510)
1833 KV pin insulator polymer
19H W fitting (B&S) 90KN, 4 Bolt
20Disc insulator (B&S) 90 KN polymer
21PG Clamp for 148 sq.mm AAA conductor
22GI Nut , Bolt & Washer of different sizes (12.251 Kg each DP without Isolator)
23Black Paint
24Yellow Colour Paint for Background
25CIVIL & SERVICES.
26Fixing of 33KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5) Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size ( 500mmx500mmx800mm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500 x 500 x 1500mm)
27Concreting ratio 1:1, 5:3 (500mm x 500mm x 2200mm) = 0.55Cu. Mtr
28Couping ratior 1:1, 5:3 with diemnsion (500 x 500 x 450) = 0.1125 Cu. Mtr.
29Installation of Earth pit, charcoal, salt etc. including construction of earthing chamber (Size: 2" x 2") and RCC slab cover.
30Construction of 33KV DP with Isolator.
31WPB 160x152 (13tr. Long, 30.44KG/Mtr.)
32Top Channel 100 x 50 x 6mm, 9.56 KG/Mtr, each channel length 4.3 mtr., 2 no"s channel required =(2 x 9.56 x 4.3)
33Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0.280 mtr. length, 6 no"s required = (6x2.36x0.280)
34Insulator Support Channel 75 x 40 x 4.8mm, 7.14KG/Mtr, each channel length 4.3 Mtr., 1 no"s channel required = (1x7.14x4.3)
35Isolator Support Channel 75 x 40 x 4.8mm, 7.14KG/Mtr, each channel length 4.3 Mtr., 2no"s channel required = (2x7.14x4.3)
36Double Pole Belting Channel 75 x 40 x 4.8mm.7.14KG/Mtr., each channel length 4.3Mtr., 4 no"s channel required =(4 x 7.14 x 4.3)
3750 x 50 x 6mm.GI Bracing Angle, 4.5Kg./mtr., each angle length 4.927 mtr., 4 nos angle required = (4 x 4.5 x 4.927)
38Isolator Operating Down Pipe support channel 75 x 40 x 4.8mm. 7.14KG/Mtr., each channel length 0.8 Mtr. 1 no"s channel required =(1 x 7.14 x 0.8)
39Down Pipe Diagonal Support Angle, 4.5Kg./mtr., each angle length 0.388mtre 1 nos angle required . (1x4.5x0.388)
40Down Pipe Base Support Angle, 4.5Kg,/mtr„ each angle length 0.34rntr., 1 nos angle required = (1x4.5x0,340)
41Isolator Support Side Channel 100X50X6rnm, 9.56 KG/Mtr., each channel length 0.5 mtr., 2 no"s channel required (2x9.56x0,5)
42Danger Plate, 2 no"s.
43Back Clamp for danger Plate 25 x 3 mm. flat, 0.59Kg/Mtr. Flat of 0.510mtr length 2 no"s e (2x0.59x0,510)
44H.T. Stay clamp, 50x8 rnm. flat, 3.14Kg/Mtre 0.511 Mtr.Length, 2 no"s qty. required ( 1 Pair)
45H.T. Stay set.(Complete )
46H.T. Stay. Insulator Type-C (2 No"s.).
477/8 SWG Stay Wire 15 kg /stay
48Gi Pipe Earthing 40mm, 3 Mtr. Long
4950 x 6mm GI Flat for earthing, 2.36kg/rntr., (15 Mtr. For L.A. 4 Mtr for Isolator Body, 2.5 mtr. For mesh formation and 2.5 mtr. For raising). 24 x2.36
50GI barbed wire anticlimbing device 3 Kg. Per support
51Back Clamp for anticlimbing device 25 x 3mm, flat 0.59Kg/ Mtr. Flat of 0.510mtr length 8 no"s = (8x0.59x0.510)
52Lightning Arrester(30KV,10KA) (Station Ctass,class-2)
5333 KV 630 AMP Double break (Turn & twist center rotating) isolator without earth switch with PI(Polymer)
5433KV pin insulator polymer
55H W fitting (B&S) 90KN, 4 Bolt
56Disc insulator (B&S) 90 KN polymer
57PG Clam. for 148sqmm AAA conductor
58GI Nut, Bolt & Washer of different sizes (22,15 Kg each DP with Isolator)
59Black Paint
60Yellow Colour Paint for Background
61CIVIL WORK.
62Fixing of 33KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5)Stay clamps with Nuts & bolts, including excvation, supply of 0,5Cum cement concrete foundation 1:2:4 size (500rnm x 500mm x 800rnm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500 x 500 x 1500 mm.)
63Concreting ratio 1:1,5:3 (500mm x 500mm x 2200mm) = 0 55Cu.mtr
64Couping ratio 1:1,5:3 with dimension(500 x 500 x 450)= 0.1125 Cu mtr
65Installation of Earth Pit, Charcoal, Salt etc: including construction of earthing chamber (Size: 2"x2") and RCC slab cover
6633KV Cut point with 180 degree angle.
67WPB 160x152 (13tr. Long, 30.44KG/Mtr.)
68Straight Cross Arm Channel 100 x 50 x 6 mm, 9.56 KG/rntr, each channel length 1.7 Mtr, 2 No"s of Channel = (2x 9.56 x1.7)
69Fish Plate 50x6 mm., 2.36 kg/Mtr., each 0,280 mtr. length, 8 no"s required = (8x2.36x0.280)
70Straight Cross Arm Top Channel 100 x 50 x 6 mm, 9.56 KG/mtr, each channel length 0.306 Mtr., 2 No"s of Channel = (2x 9 56x0,306)
71Danger Plate, 1 no"s,
72Back Clamp for danger Plate 25 x 3 mm. flat, 0.59Kg/Mtr. Flat of 0,510mtr length 1 no"s = (1x0.59x0.510)
73GI barbed wire anticlimbing device 3 Kg. Per support
74Back Clamp for anticlimbing device 25 x 3 mm. flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 no"s = (4x0.59x0.510)
7533KV pin insulator polymer
76H W fitting B&S 90KN 4 Bolt
77Disc insulator (B&S) 90 KN polymer
78Earthing of Support ( Coil Type )
79No-8 GI wire (Dia 4,6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
80PG Clamp for 148 sqmm AAA conductor
81GI Nut , Bolt & Washer of different sizes (4.879 Kg each 180 deg. Cut point)
82Black Paint
83Yellow Colour Paint for Background
84CIVIL WORK.
85Concreting ratio1:1,5:3 (500mmX500mmX2200mm)= 055Cu.mtr
86Couping ratio 1:1,5:3 with dimension (500X500X450)= 0.1125 Cu mtr
8733KV Cut point with 90 degree angle.
88WPB 160x152 (13tr. Long, 30.44KG/Mtr.)
89Straight Cross Arm Channel 100 x 50 x 6 mm, 9.56 KG/rntr, each channel length 1.7 Mtr., 4 No"s of Channel = (4x 9.56x1.7)
90Fish Plate 50x6 mm. 2.36 kg/Mtr., each 0.280 mtr. length, 16 no"s required = (16 x 2.36 x 0.280)
91Straight Cross Arm Top Channel 100 x 50 x 6 mm, 9.56 KG/mtr, each channel length 0.306 Mtr., 4 No"s of Channel = (4x 9 56x0.306)
92Danger Plate, 1 no"s,
93Back Clamp for danger Plate 25 x 3 mm. flat, 0.59Kg/Mtr. Flat of 0,510mtr length 1 no"s = (1x0.59x0.510)
94GI barbed wire anticlimbing device 3 Kg. Per support
95Back Clamp for anticlimbing device 25X3 mm. flat, 0.59Kg/Mtr, Flat of 0.510mtr length 4 no"s = (4x0.59x0.510)
9633KV pin insulator polymer/ 4nos each 90Deg cut point.
97H W fitting B&S 90KN 4 Bolt
98Disc insulator (B&S) 90 KN polymer
99Earthing of Support (Coil Type )
100No-8 GI wire (Dia 4,6mm) 0.131 KG/ Mtr- 2 Mtr for connecting pole with Coil earthing
101PG Clamp for 148 sqmm AAA conductor
102H.T. Stay clamp, 50x8 rnm. flat, 3.14Kg/Mtre 0.511 Mtr.Length, 2 no"s qty. required ( 1 Pair)
103H.T. Stay set.(Complete )
104H.T. Stay. Insulator Type-C (2 No"s.).
1057/8 SWG Stay Wire 15 kg /stay
106GI Nut , Bolt & Washer of different sizes (11.31 Kg each 90deg. Cut point)
107Black Paint
108Yellow Colour Paint for Background
109CIVIL WORK.
110Concreting ratio 1:1,5:3 (500mmX500mmX2200mm) = 0 55Cu.mtr
111Couping ratio 1:1,5:3 with dimension( 500X500X450)= 0.1125 Cu mtr
112Fixing of 33KV line Complete stay set includes 1) Turn Buckle Assembly 2) Stay Rod & Stay plate 3) Stay Insulator 4) Stay Wire. 5) Stay clamps with Nuts & bolts, including excvation, supply of 0.5Cum cement concrete foundation 1:2:4 size (500rnm x 500mm x 800rnm) using 20mm BHG metal with all labour and material (Excavation of earth will be done of size 500 x 500 x 1500 mm.)
11333KV line length in km with 50mtr span.
114WPB 160x152 (13tr. Long, 30.44KG/Mtr.)
11533 KV V cross Arm (GI) 22Kg each
116Top bracket 100x50x6mrn GI channel ( 2kg each)
117Danger Plate, 1 no"s.
118Back Clamp for danger Plate 25x3 mm. flat, 0.59Kg/Mtr. Flat of 0.510intr length 1 no"s = (1x0.59x0.510)
119GI barbed wire anticlimbing device 3 Kg. Per support
120Back Clamp for anticlimbing device 25 x 3 mm. flat, 0.59Kg/ Mtr. Flat of 0.510mtr length 4 no"s = (4x0.59x0.510)
12133KV pin insulator polymer
122Earthing of Support (Coil Type )
123No-8 GI wire (Dia 4.6mm) 0.131 KG/ Mtr.- 2 Mtr. For connecting pole with Coil earthing
124GI Nut , Bolt & Washer of different sizes (1.45 Kg/ Pin Point)
125148 sqmm AAA conductor
126Black Paint
127Yellow Colour Paint for Background
128CIVIL WORK.
129Concreting ratio 1:1.5:3 (500mmX500mmX2200mm) = 0 55Cu.mtr
130Couping ratio 1:1,5:3 with dimension (500X500X450)= 0.1125 Cu mtr
131PART-B: Supply and laying of 33KV 1C x 400sqmm XLPE UG cable for road crossing and railway crossing from NALCO Premises to NALCO 33/11KV S/S (front gate).
132Supply of materials for 33KV 1c x 400sqmm Al. XLPE insulation UG cable (along with 1core spare cable) with accessories.
133Supply of 1C x 400 sqmm, 33 KV, XLPE, Power cable Armored, aluminium conductor, stranded, including the irtermination materials like glands, lugs, tagging etc. as required as per technical specifications and scope of the works.
134Supply of 33 KV 1C X 400 sq.mm. Heat Shrink In Door cable termination kit complete with all accessories and tagging etc. as per technical specifications and scope of the works.
135Supply of 33 KV 1C X 400 sq.mm. Heat Shrink Out Door cable termination kit complete with all accessories and tagging etc. as per technical specifications and scope of the works.
136Supply of 33 KV, 1C X 400 sqmm Heat Shrink type termination kit complete with all accessories and tagging etc. as per technical specifications and scope of the works.
137Erection, commissioning & testing of 33KV new line by 3c x 1core, 400sqmm XLPE UG cable with one spare.
138Laying, commissioning & testing of 1C 4runs x 400 sqmm, 33 KV, XLPE insulation (extruted type) UG cable (with one single 1core, 400sqmm XLPE cable as spare) in trefoil formation by open trench method.
139Erection of Straight through jointing kits Heat Shrinkable type suitable for 33KV, 1core 400sqmm aluminium UG cable kits.
140Erection of outdoor termination kits Heat Shrinkable type suitable for 33KV, 1core 400sqmm aluminium UG cable kits. HT UG cable kits.
141Erection of indoor termination kits Heat Shrinkable type suitable for 33KV, 1core 400sqmm aluminium UG cable kits. HT UG cable kits.
142Laying, commissioning & testing of 33KV, 1Core, 4runs, 400sqmm, XLPE insulation (extruted type) UG cable (with one single 1core, 400sqmm, XLPE cable as spare) including looping at cable terminations and straight through joints by HDD method with HDPE pipe for laying of individual run of UG cable at main road and unaccessable place.
143CIVIL PORTION.
144Civil works with supply of all materials like cement, MS tor rod, brick, coarse & fine aggregates and labour, T&P, etc for UG Cable trench.
145Earth work excavation of soil (2mtr. Width x 1.65mtr. Depth)
146Earth work excavation of normal soil Trench Dimenstion: (2mtr. Width x 1.65mtr. Depth)
147Earth work excavation of hard rock Trench Dimenstion: (2mtr. Width x 1.65mtr. Depth)
148Shifting of excavated soil to a lead distance of 10km.
149Filling with fine river sand after laying of cable inside the trench.
150Back filling with excavated soil outside and above the trench.
151Supply and erection of prefabricated RCC partition slab 950mm x 450mm x 50mm (M-30 grade)
152Supply and erection of prefabricated RCC trench (1.050mtrD), 150mm thick (M-30 grad) cast-in SITU.
153Supply of rod, bending, cutting and binding of prefabricated RCC trench (0.898 Qunit/cum)-Cast-in-SITU.
154Supply of rod, bending, cutting and binding of prefabricated RCC slab (0.687Qunit/cum).
155Damage of asphalt/tar rod and other utilities and reconstructing to bring to its original shape after laying of cable in open trench (1mtr width)
156Bedding with fine river sand after laying of cable below trench (width 1500mm, thickness 100mm througout)
157PCC (1:3:6) below trench (width 1500mm, thickness 100mm throughout)
158Supply and erection of GI Pipe of dia, 150mm Class-B (8mtr)
159Supply and erection of cable route marker along the cable route at an interval of 30 mtrs with civil works.
160N.B: The bidders are required to Quote their rates excluding of Goods & Service Tax (GST). GST as applicable will be paid extra. The existing rule of Govt. and any amendment made in future will be followed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail