| 1 | Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copperconductor cable as required |
| 2 | Group C. |
| 3 | Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. |
| 4 | Group C. |
| 5 | Providing and installation of following type of Ultra slim decorative LED Batten with extruded aluminium heat sink, with antiglare polycarbonate diffuser and energy efficient constant current, integral electronic driver, suitable for input voltage: 220-240 V, 50/60 Hz, complete with all accesories, including mounting clips & loop in loop out wire, connections, testing and commissioning etc. as required, with two year warranty. Make: Philips, Twinkle, GE or any other approved by Engineer-in-Charge. |
| 6 | LED Batten Light 20 Watt. |
| 7 | Providing and installation of following type of Ultra slim decorative Inverter LED Batten withwith square profile and polycarbonate channel suitable for input voltage: 220-240 V, 50/60 Hz, having Lithium Ion battery with charging time 8hours-10 hours and back up time upto 4 hours, complete with all accesories, including mounting clips & loop in loop out wire, connections, testing and commissioning etc. as required, with two year warranty. Make: Havells, Philips, Twinkle, GE or any other approved by Engineer-in-Charge. |
| 8 | Inverter LED Batten Light 20 Watt. |
| 9 | Providing and installation of Decorative wall light fixture made up of Polycarbonate, suitable for 9 W LED lamp B22 base for indoor applications, complete with all accessories, including making connections, testing and commissioning etc and excluding LED Lamp. as required. Make: Havells or any other approved by Engineer-in-Charge. |
| 10 | Decorative Wall Bracket |
| 11 | Providing and installation of following type of Surface/Recess mounting square/round type LED Panel Light, powder coated housing made of CRCA sheet, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including making connections, testing and commissioning etc. as required with two years warrenty. Make: Twinkle, GE, Philips or any other approved by Engineer-in-Charge. |
| 12 | LED Panel Light 36 Watt.(Size:- 2\" x 2\" feet) |
| 13 | Providing and installation of following type of surface/recess mounting round/square LED Downlight finish with drop down PC diffuser to deliver low glare illumination with optimized heat sink for efficient heat dissipation suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including making connections, testing and commissioning etc. as required with Two years Warrenty. Make: Philips, Twinkle, GE or any other approved by Engineer-in-Charge. |
| 14 | LED Downlight6 WH. |
| 15 | LED Downlight15 WH. |
| 16 | Providing and installation ofLED Emergency Retrofit Lamp with rechargeableemergency light polycarbonate body and aluminium heat sink; suitable for input voltage: AC 220-240 V, 50/60Hz, including mounting in existing fixture, testing etc. as required complete in all respects. Make: Philips, Bajaj, Syska, Panasonic, Havell\"s or any other approved by Engineer-in-Charge. |
| 17 | LED 9 W INVERTER BULB B22 |
| 18 | Providing and installation of surface mounted, LED Bulk head Fitting IP65 protection, comprising of high brightness LEDs, suitable for input voltage: AC 220-240 V, 50/60Hz, complete with all accessories, including making connections, testing and commissioning etc. as required. Make: Twinkle, Philips, GE or any other approved by Engineer-in-Charge. |
| 19 | LED Bulk Head Fitting 6 Watt. |
| 20 | Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- |
| 21 | Exhaust Fan, Heavy duty, 300 mm sweep |
| 22 | Exhaust Fan, Light duty, (Domestic) 225 mm sweep |
| 23 | Providing & fixing the louvers/shutters complete with frame for exhaust fans of all sizes as required:- |
| 24 | Supplying and fixing following rating Piano-type switch /socket on the existing switch box / cover including connections etc. as required. |
| 25 | S.P. 5/ 6 Amps one way Modular switch. |
| 26 | 5 pin, 5/ 6 Amps Modular socket outlet. |
| 27 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required. |
| 28 | Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required. |
| 29 | Providing and installation of stationary storage type Electric water heater (Geyser) of various sizes by means of Expansion-bolts with nuts and washers, including embedding of expansion-bolts in the wall, providing and fixing of Non-return valve, Dead weight safety valve, 2 No C.P. connection rods 18\" long, making good the damages, electrical connections, safety valve connections, testing and commissioning etc. as required:- |
| 30 | 50 Liter capacity water heater (Cat-A) |
| 31 | 35 Liter capacity water heater (Cat-A) |
| 32 | Supplying and installation of following type Hot Air Blower with Pre coated GI body Casing, Aluminium Powder Coated Grills, Aluminium centrifugal type Blowers, 3 speed 1 phase with extended shaft Motor, Strip type finned heaters of ‘Daspass’ make and complete with Thermostat, Contactor & Speed selector complete with all accessories including making connections, testing etc. as required. Make: Airef or any other approved by Engineer-in-Charge. |
| 33 | 3-Phase Hot Air Blower 4.5 KW |
| 34 | 3-Phase Hot Air Blower 6.0 KW |
| 35 | Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, unarmoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size |
| 36 | Unarmoured cable 10 sq. mm (four core) |
| 37 | Unarmoured cable 16 sq. mm (four core) |
| 38 | Unarmoured cable 35 sq. mm (3.5 core) |
| 39 | Earthing with copperearth plate 600 mmx600 mmx 3 mm thick, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required. |
| 40 | Extra for using salt and charcoal for G.I. or copper plate earth electrode complete as required. |
| 41 | Providing and fixing 8 SWG (4 mm dia.) copper wire on surface or in recess for loop earthing as required |
| 42 | Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. |
| 43 | 2x1.5 Sq. mm. |
| 44 | 2x4.0 Sq. mm. |
| 45 | Wiring for circuit/sub-main with 4x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed Steel conduit along with 2 No.1.5 Sq.mm.(4X1.5+2X1.5) HRFRLS/PVC insulated single core copper conductor cable for earthing as required |
| 46 | 4x1.5+2X1.5 Sq. mm. |
| 47 | Wiring for light plug with 2x1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. |
| 48 | Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required. |
| 49 | Wiring for circuit / sub-main with 4x6 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.6 Sq.mm. (4x6+2x6) HRFRLS/PVC insulated single core copper conductor cable forearthing as required. |
| 50 | Supplyinganderection of 6amps. to 32 amps. rating, 10 KA breaking capacity, 240volts, \"C\" curves, miniaturecircuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- |
| 51 | Single pole 5/6 Amp. Cat-A. |
| 52 | Single pole 15/16 Amp. Cat-A. |
| 53 | Double pole 16 Amps. Cat-A |
| 54 | Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 55 | MCB 4-Pole 25 Amp |
| 56 | Supplying and fixing following rating, double pole (single phase & neutral) 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: Havells or any other approved by Engineer-in-Charge. |
| 57 | RCCB DP 16 Amp. |
| 58 | Providing and fixing following rating, Four pole (Three phase & neutral) 10 KA breaking capacity 240/415 volts, Residual Current Breaker with Overcurrent Protection (RCBO), having a sensitivity current up to 300 miliampers, suitable for protection against leakage current, short circuit & over load in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make: L&T, Havells, Schneider or any other approved by Engineer-in-Charge. |
| 59 | FP RCBO 16 Amp. |
| 60 | Providing and installation of Over/Under Voltage Protection Device for Protection against sudden voltage surges & sudden voltage drop that trips the attached circuit breaker during over/under voltage fault so that the equipments are proteced from over/under voltage complete including making connections, testing and commissioning etc. as required, Make:Havells. L&T, Schneider or any other approved by Engineer-in-Charge. |
| 61 | Single Phase Over/under Voltage Protection |
| 62 | Providing, fixing and installation of following rating and breaking capacity MCCB with Thermal Release Having inbuilt Overload and Short Circuit Protection in the existing cubical panel board with Enclosure including drilling holes in the cubical panel, suitable for input voltage: 415/500 Volt AC, 50 Hz, complete with all accesories, including making connections, testing and commissioning etc. as required, Make: L&T, Havells or any other approved by Engineer-in-Charge. |
| 63 | MCCB 16 Amp. 4P with Enclosure |
| 64 | MCCB 32 Amp. 4P with Enclosure |
| 65 | Supplyingand fixingoffollowingway, singlepoleandneutral sheetsteel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- |
| 66 | Single door-4 way |
| 67 | Distribution Board : -Supplyingand fixingoffollowing way L&T make TPN DB 4-12 Way DD, FP MCB /Isolator /RCCB/RCBO as incomer, of suitable dimensions made from 1.6 mm thick CRCA sheet on surface / recess with Incomer FP MCB spreader links, busbar, 8 module sub-incomer in and 4-12 module MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted,Metal Door IP 43 including earthing etc. as required. |
| 68 | Double door TPN DB 6-way |
| 69 | Double door TPN DB 8-way |
| 70 | Sub-Main Distribution Panel:- Providingand fixing floor/wall mounted L&T make SMDB PanelTN250D, O/G 100A, 4-Ways Panel, having Main MCCB Incomer 125 Amp. & Outgoing 2-Way Sub-Incomer 20 & 100 Amp. of suitable dimensions made from 1.6 mm thick CRCA sheet, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels, interconnections,hosphatized and powder painted and LED phase indicating set, Digitial Metering complete with following accessories including earthing etc. as required : - |
| 71 | Incoming device:- |
| 72 | DU250C 3 Pole MCCB - 125A breaking capacity 25 KA |
| 73 | Cat No. :- CM90631OOMO |
| 74 | Outgoing Device:- |
| 75 | DN0-100C 3 Pole MCCB - 100 A breaking capacity 25 KA |
| 76 | Cat No. CM91612OOKOOG |
| 77 | Outgoing Device:- |
| 78 | DN0-100C 3 Pole MCCB-20A breaking capacity-50 KA |
| 79 | Cat No.-CM91612OOCOOG |
| 80 | Metering, Bottom Cabling & Corner Box:- |
| 81 | Provision of 3 Nos. of 1-phase ammeter (96*96), 1 No. of 1-phase voltmeter (96X96) with voltage selector switch & indicating lamps. |
| 82 | Metering Extension Box [Cat No. CM91064OOTO] |
| 83 | Bottom Cabling Box [Cat No. CM 91062OOOO] |
| 84 | Corner Box [Cat No. CM91089OOOO] |
| 85 | Left Side Cabling Box [Cat No. CM91120OODO] |
| 86 | Right Side Cabling Box [Cat No. CM91121OODO] |
| 87 | 1 Ph LED Ammeter Cl 1[Cat No. WL111010OOOO] |
| 88 | 1 Ph LED Voltmeter Cl 1[Cat No. WL111010OOOO] |
| 89 | Voltmeter selector switch [Cat No. 61312 SAB12TDYR] |
| 90 | LED RED indicator 22.5 mm [Cat No. EPLR240A] |
| 91 | LED Yellow indicator 22.5 mm [Cat No. EPLY240A] |
| 92 | LED Green Indicator 22.5 mm [Cat No. EPLG240A] |
| 93 | Supplying and fixing sheet metal bus-bar chamber suitable for 32 Amp. 415 volts capacity with 4 No. copper strip bus-bars with enclosure made from 1.6 mm thick M.S. sheet with all accessories including connections, earthing the body etc. as required. Make:- Havells, Indo Gold, Anchor, Indo Asian etc. |
| 94 | Supplying and fixing sheet metal bus-bar chamber suitable for 100 Amp. 415 volts capacity with 4 No. copper strip bus-bars with enclosure made from 1.6 mm thick M.S. sheet with all accessories including connections, earthing the body etc. as required. Make:- Havells, Indo Gold, Anchor, Indo Asian etc. |