}

Tender For Supply Of Items To Instrumentation Engineering Department Through Mhrd, Kannur-Kerala

Directorate Of Technical Education-DTE has published Tender For Supply Of Items To Instrumentation Engineering Department Through Mhrd. Submission Date for this Tender is 20-10-2022. Coats and Jackets Tenders in Kannur Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

34128307
Tender For Supply Of Items To Instrumentation Engineering Department Through Mhrd
Open Tender
Indian
Kerala
Kannur
20-10-2022

Tender Details

Supply Of Items To Instrumentation Engineering Department Through Mhrd Supply Of Items To Instrumentation Engineering Department Through Mhrd , Hart Communicator With Configurator - Experimental Setup Usb Hart Modem With All Accessories Including Software Windows Based And Windows Based Handheld Monitoring Device With Touch Screen For Calibration And Measurement In 4-20Ma Loop. Specifications:- 1.Modem Compatible With All Certified Hart Devices And Wired Hart Configurations.Monitoring And Configuration Software Must Be Licenced. 2.Complete Hart Device Modem Interface With Usb Cable,Features Includes Galvanic Isolation For Loop. 3.Perform Basic Configuration Of Any Field Device And Do Device Calibrations Using Software. 4. Software Must Includes Usb Drivers For Windows. Certifications:Fcc And Ce,Rohscompliant. Handheld Device: Windows Based With Usb Connectivity And Battery Backup In Specifications Clearly Mention Brand Name,Model,And Product Selection Code Of Each And Every Components. , Smart Temperature Transmitter Calibration Set Up For Thermocouple Sensor (To Calibrate Smart Temperature Transmitter For Different Ranges Of Temperature Using Tc Sensor And Perform A. Basic Setup B. Calibration) The Setup Must Include The Following: 1. Thermocouple With Smart Temperature Transmitter,J Type Head Mounted,6Mm Dia,150Mm Length With 1/2 Bsp Connection. Head Mounted Temperature Transmitter With Hart Protocol,2-Wire Technology, 4~20 Ma Analog Output, Wide Supply Voltage Range, Loop Powered,0.08% Of Span %,Temperature Range -100 To +600 Degree Celsius,24 Vdc Loop Power, Process Indicator With 4 Digit With 0.1 Degree Celsius Msd, 2. Oil Temperature Bath Upto 150 Deg C, Including Heat Cool Pid Controller , Ssr Driven Closed Loop With Internal Sensor And Heating Cooling System. Oil Tank Must Be Ss304 With Minimum 2Ltr Capacity And Must Have Stirrer For Circulation. 3.24V Dc Power Source With Necessary Protection And Industrial Panel. 4. The Whole Systemsetup Must Be In Ms Powder Coated Standalone Mobile Table With Lockable Castor Wheels. All The Components Used Be Industrial. Electrical Wiring Connection To Be Flexible For To Connect Field Devices. Panel With Switches, Indicator, Test Points With Banana Connectors As Required, Multi Strand Wire With Proper Insulated Lugs, Ferruling & Neat Wire Dressing & Clamping. 6.Experiment Manuals And Documents Must Be Provided. All Products Must Be Iso Certified,, In Specification Clearly Mention Brand Name, Model, And Product Selection Code Of Each And Every Components. , Smart Temperature Transmitter Calibration Set Up For Rtd Sensor (To Calibrate Smart Temperature Transmitter For Different Ranges Of Temperature Using Rtd Sensor And Perform A. Basic Setup B. Calibration) The Setup Must Include The Following: 1. Rtd With Smart Temperature Transmitter,Pt100, Class A Accuracy, Type 3 Wire Head Mounted,6Mm Dia,150Mm Length With 1/2 Bsp Connection. Head Mounted Temperature Transmitter With Hart Protocol,2-Wire Technology, 4~20 Ma Analog Output, Wide Supply Voltage Range, Loop Powered,0.08% Of Span %,Temperature Range -100 To +600 Degree Celcius,24 Vdc Loop Power, Process Indicator With 4 Digit With 0.1 Msd 2. Oil Tempearture Bath Upto 150 Deg C, Including Heat Cool Pid Controller , Ssr Driven Closed Loop With Internal Sensor And Heating Cooling System.Oil Tank Must Be Ss304 With Minimum 2Ltr Capacity And Must Have Stirrer For Circulation. 3.24V Dc Power Source With Necessary Protection And Industrial Panel. 4.The Whole Systemsetup Must Be In Ms Powder Coated Standalone Mobile Table With Lockable Castor Wheels. All The Components Used Be Industrial. Electrical Wiring Connection To Be Flexible For To Connect Field Devices. Panel With Switches, Indicator, Test Points With Banana Connectors As Required, Multi Strand Wire With Proper Insulated Lugs, Ferruling & Neat Wire Dressing & Clamping. 5.Experiment Manuals And Documents Must Be Provided. All Products Must Be Iso Certified,, In Specification Clearly Mention Brand Name, Model, And Product Selection Code Of Each And Every Components. , Smart Displacer Type Level Transmitter Calibration Set Up (To Calibrate Smart Displacer Type Level Transmitter For Different Ranges Of Level And Performance) Setup Consist Of 2 Tanks(1 Measuring Tank And One Sump Tank).A Circulating Water Plant Or Circulating Water System Including Pump And Necessary Valves Including Bypass Valve. Using This We Can Able To Manipulate The Level Of Measuring Tanks. The Setup Must Include The Following: 1.Measuring Tanks110cm Height, Min Of 10 Ltr Capacity And Sump Tank Min Of 20 Ltr Capacity, All Tank Made Of Ss304 And Finished With Mat Steel Finish. Sight Glass And Level Scale Required For The Measuring Tank. 2.Pump Must Be 0.5Hp,Ss Centrifugal Pump, Minimum 1 Inch Pipe Line Of Ss Orhigh Pressure Withstanding Plastic. 3.Smart Displacer Type Transmitter With Hart Protocol, Display And Keys Integrated For Calibration,0-100Cm Measurement Range,0.01% Accuracy, International Iso Certified Ce Approved Make,24 Vdc Supply,4-20Ma Output, Loop Powered. 4.24V Dc Power Source, Digital Panelmeter To Display 4-20 Ma, With Necessary Protection And Industrial Panel. 5. Solenoid Valves For Filling And Unfilling The Measuring Tank With Necessary Switches. 6. The Whole Systemsetup Must Be In Ms Powder Coated Standalone Mobile Table With Lockable Castor Wheels.All The Components Used Be Industrial. Copper Tubing For Air Connection, Electrical Wiring Connection To Be Flexible For To Connect Field Devices. Panel Withswitches, Indicator, Test Points With Banana Connectors As Required, Multi Strand Wire With Proper Insulated Lugs, Ferruling & Neat Wire Dressing & Clamping. 7.The Setup Must Be Ready To Do The Experiments. Experiment Manuals And Documents Must Be Provided.All Products Must Be Iso Certified, ,In Specification Clearly Mention Brand Name, Model, And Product Selection Code Of Each And Every Components. , Smart Differential Pressure Transmitter (Dpt) Calibration Set Up (To Calibrate Smart Differential Pressure Transmitter For Different Ranges Of Differential Pressure And Performance& To Calibrate Smart Dp Type Level Transmitter For Different Ranges Of Dp And Performance) Setup Consist Of 3 Tanks(2 Measuring Tank And One Sump Tank).A Circulating Water Plant Or Circulating Water System Including Pump And Necessary Valves Including Bypass Valve. Using This We Can Able To Manipulate The Level Of Measuring Tanks. The Dp Port Of Dpt Connected To Both Tank. The Setup Must Include The Following: 1.Measuring Tanks Of 500Mm Height, Min Of 10 Ltr Capacity And Sump Tank Min Of 40 Ltr Capacity, All Tank Made Of Ss304 And Finished With Mat Steel Finish. Sight Glass And Level Scale Required For Both Measuring Tanks. 2.Pump Must Be 0.5Hp,Ss Centrifugal Pump, Minimum 1 Inch Pipe Line Of Ss Orhigh Pressure Withstanding Plastic. 3.Smart Dp Transmitter With Hart Protocol, Display And Keys Integrated For Calibration,0-1000Mm H2o Measurement Range,0.01% Accuracy, International Iso Certified Ce Approved Make,24 Vdc Supply,4-20Ma Output, Loop Powered. 4.24V Dc Power Source, Digital Panelmeter To Display 4-20 Ma, With Necessary Protection And Industrial Panel. 5. Solenoid Valves For Filling And Unfilling The Measuring Tank With Necessary Switches. 6.The Whole Systemsetup Must Be In Ms Powder Coated Standalone Mobile Table With Lockable Castor Wheels. All The Components Used Be Industrial. Copper Tubing For Air Connection, Electrical Wiring Connection To Be Flexible For To Connect Field Devices. Panel Withswitches, Indicator, Test Points With Banana Connectors As Required, Multi Strand Wire With Proper Insulated Lugs, Ferruling & Neat Wire Dressing & Clamping. 7.The Setup Must Be Ready To Do The Experiments. Experiment Manuals And Documents Must Be Provided. All Products Must Be Iso Certified,, In Specification Clearly Mention Brand Name, Model, And Product Selection Code Of Each And Every Components. , Smart Pressure Transmitter Calibration Set Up : (To Calibrate Smart Pressure Transmitter For Different Ranges Pressure And Performance) Setup Consist Of One Air Pressure Tank Of Min 10Ltr Capacity And Pressure Withstand Capacity Of 20Bar,Powder Coated. Pressure Of Tank Can Be Increase Or Decrease By Means Of Solenoid Valves And Switches ,Flow Control Valves. The Pressure Port Of Tank Connected To Pressure Transmitter. The Setup Must Include The Following: 1.Pressure Tank 10Ltr Capacity,20Bar Withstanding Capacity With Safety Release Valve, Pressure Gauge Of 4 Inch Dial 0-10Bar Bourdon Type Ssbody,1/4 Bsp Connection. 2.Smart Pressure Transmitter With Hart Protocol ,Display And Keys Integrated For Calibration,0-10Bar Measurement Range,Read Out : 0 - 100%, 4-20Ma Lcd Display,0.05% Accuracy, International Iso Certified Ce Approved Make,24V Supply,4-20Ma Output, Loop Powered. 3.24V Dc Power Source, Digital Panelmeter To Display 4-20 Ma, With Necessary Protection And Industrial Panel. 4. Flow Control And Solenoid Valves For Increasing/Decreasing The Pressure Tank With Necessary Switches. 5. One Air Compressor 0-10Bar Range, Portable,10Ltr Capacity, Single Phase 230V Supply. 6.The Whole Systemsetup Must Be In Ms Powder Coated Standalone Mobile Table With Lockable Castor Wheels. All The Components Used Be Industrial. Copper Tubing For Air Connection, Electrical Wiring Connection To Be Flexible For To Connect Field Devices. Panel Withswitches, Indicator, Test Points With Banana Connectors As Required, Multi Strand Wire With Proper Insulated Lugs, Ferruling & Neat Wire Dressing & Clamping. 7.The Setup Must Be Ready To Do The Experiments. Experiment Manuals And Documents Must Be Provided. All Products Must Be Iso Certified,, In Specification Clearly Mention Brand Name ,Model, And Product Selection Code Of Each And Every Components. , Smart Control Valve With Positionerset Up (To Perform Control Valve Stroke Test Using 4-20Ma Source / Calibrate Control Valve Positioner Using 4-20Ma Source) Setup Consist Of A Circulating Closed Loop Water Plant Or Circulating Water System Including Smart Control Valve, Tank, Pump And Necessary Valves Including Bypass Valve And Rotameter. Using This We Can Able To Manipulate The Water Flow Through The Control Valve To Study Valve Characteristics. The Setup Must Include The Following: 1.One Linear Characteristics Diaphram Operated Control Valve With 15Mm Stroke 1/2 Inch Sizewith Smart Positionerhart Protocol For Study The Characteristics. Input 4-20Ma With Flow Of 2000Lph. 2.Sump Tank Min Of 20 Ltr Capacity. All Tank Made Of Ss304 And Finished With Mat Steel Finish. 3.Pump Must Be 0.5Hp,Ss Centrifugal Pump, Minimum 1 Inch Pipe Line Of Ss Orhigh Pressure Withstanding Plastic With Plastic Welding. 4. 4-20Ma Current Source With Display, With Necessary Protection And Industrial Panel. 5,Rotameter 1 Inch Size Flow : 200-2000 Lph, Ss Thread, Clear Acrylic Type. 6.One Air Supply Regulator Of 0-7 Bar To Regulate The Control Valve Input Air Supply. 7.The Whole Systemsetup Must Be In Ms Powder Coated Standalone Mobile Table With Lockable Castor Wheels. All The Components Used Be Industrial. Copper Tubing For Air Connection, Electrical Wiring Connection To Be Flexible For To Connect Field Devices. Panel Withswitches, Indicator, Test Points With Banana Connectors As Required, Multi Strand Wire With Proper Insulated Lugs, Ferruling & Neat Wire Dressing & Clamping. 8.The Setup Must Be Ready To Do The Experiments. Experiment Manuals And Documents Must Be Provided. All Products Must Be Iso Certified,, In Specification Clearly Mention Brand Name, Model, And Product Selection Code Of Each And Every Components. , Regulated Dual Variable Dual Power Supply Input : 230V Ac, ±10%, 50Hz, 1 Phase Output: (0 - 32V, 0-5A) Variable Dual Output. Continuously Variable By Coarse And Fine Knobs In Each Tracks For Each Current And Voltage , Digital Displays(3 Digit Dpm) For Voltage And Current For Each Tracks, With Protection Against Short Circuits And Continuous Overloads. Line And Load Regulation Cv - Cv ±0.01% +2Mv; Line And Load Regulation Cc - Cc ±0.1% +2Ma Output Ripple Cv (Max.) - 1Mv Rms, Output Ripple Cc (Max.) - 0.05% Protection - Ol/Sc (Constant Current Type) Indication (Led) - For Cv And Cc Powder Coated Metallic Rustproof Body With Not Less Than 3 Mm Thickness. All Products Must Be Iso Certified, In Specification Clearly Mention Brand Name And Model. , Multiprocess Control Trainer Setup: Setup Consist Of A Circulating Closed Loop Water Plant Or Circulating Water System Including Control Valve, Tanks, Independent Pumps And Necessary Valves Including Bypass Valves And Rotameters. Using This We Can Able To Do Flow Control Loop With Pid, Level Control Loop With Pid,And Pressure Control Pid, As Independent Experiments. The Setup Must Include The Following: 1.One Linear Characteristics Diaphram Operated Control Valve With 15Mm Stroke 1/2 Inch Size, Type : High Capacity Globe Seat Leakage Class (As Per Ansi/Fci 70.2)With Electropneumatic Positioner Of4-20Ma Input. 2. Measuring Tank With Volumetric Measurement Scale And 1000Mm Level,Min Of 25 Ltr Capacity. Sump Tank Min Of 40 Ltr Capacity. All Tank Made Of Ss304,With Sight Glass, And Finished With Mat Steel Finish. 3.Two Nos Smart Dp Transmitter For Flow And Level Measurement With Hart Protocol, Display And Keys Integrated For Calibration,0-1000 Mm H2o Measurement Range,0.01% Accuracy, International Iso Certified Ce Approved Make,24V Supply,4-20Ma Output, Loop Powered 4,.Smart Pressure Transmitter With Hart Protocol, Display And Keys Integrated For Calibration,0-10Bar Measurement Range, Read Out : 0 - 100%, 4-20Ma Lcddisplay,0.05% Accuracy, International Iso Certified Ce Approved Make,24V Supply,4-20Ma Output, Loop Powered. 5, Pressure Tank Of 24 Litters With Necessary Valves For Pressure Loop. 6. One No. Oforifice Plate(Ss304)And Assembly Grade With Flange 1/2 Inch Size For Flow Measurement. 7.Two Nos Pumps 0.5 Hp, Ss Centrifugal Pump, Minimum 1 Inch Pipe Line Of Ss Orhigh Pressure Withstanding Plastic With Plastic Welding. 8. Rotameters 2 Nos. 1 Inch Size Flow : 200-2000 Lph, Ss Thread, Clear Acrilic Type. 9, Plc Control Station With 3 Analog Inputs And One Analog Output With Necessary Digital Inputs And Outputs To Operate All Loops Directly From Panel Side.Plc Must Have Ethernet Connectivity With Supported Protocols Profinet And Modbus Tcp Ip. 10.Required All Pneumatic Components To Fullfill The Process Loops Such As Frl, Needle Valves Etc. 11.All Loops Can Be Operated Using A Scadasystem Includes, Trend Of All Analog Signals And Pid Tuning. Scada Direct Profinet Connectivity To Plc And Computer With Intel I5 Processor, 8Gb Ddr3 Ram,1Tb Sata Hdd, Licenced Windows 10 Professional. 12.The Whole Systemsetup Must Be In Ms Powder Coated Standalone Mobile Table With Lockable Castor Wheels. All The Components Used Be Industrial. Copper Tubing For Air Connection ,Pressure Gauges 4Inches 3Nos,Electrical Wiring Connection To Be Flexible For To Connect Field Devices. Panel Withswitches, Indicator, Test Points With Banana Connectors As Required, Multi Strand Wire With Proper Insulated Lugs, Ferruling & Neat Wire Dressing & Clamping. 13.The Setup Must Be Ready To Do The Experiments. Experiment Manuals And Documents Must Be Provided. All Products Must Be Iso Certified,, In Specification Clearly Mention Brand Name, Model,And Product Selection Code Of Each And Every Components.

Key Value

Document Fees
INR 4838 /-
EMD
INR 20500.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail