}

Comprehensive Annual Operation And Maintenance Of Hvac, Ac, Ahu, Air Curtain, Ro Water Coolers Installed At Various Monuments At Jaipur., jaipur-Rajasthan

Development Authority-DA has published Comprehensive Annual Operation And Maintenance Of Hvac, Ac, Ahu, Air Curtain, Ro Water Coolers Installed At Various Monuments At Jaipur.. Submission Date for this Tender is 11-10-2022. Air Fittings and Connectors Tenders in jaipur Rajasthan. Bidders can get complete Tender details and download the document.




Tender Notice

34118863
Corrigendum : Comprehensive Annual Operation And Maintenance Of Hvac, Ac, Ahu, Air Curtain, Ro Water Coolers Installed At Various Monuments At Jaipur.
Open Tender
Indian
Rajasthan
jaipur
11-10-2022

Tender Details

Comprehensive Annual Operation And Maintenance Of Hvac, Ac, Ahu, Air Curtain, Ro Water Coolers Installed At Various Monuments At Jaipur.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 04-Oct-2022 Date Extension Date 11-10-2022

Key Value

Document Fees
INR 1000 /-
EMD
INR 46380.0 /-
Tender Value
INR 23.19 Lakhs /-

BOQ Items

Name of Work: Comprehensive Annual Operation and Maintenance of HVAC, AC, AHU, Air Curtain, RO water coolers installed at various monuments at Jaipur
Sl. No. Item Description
1Providingexperienced and Highly skilled/skilled/ semi-skilled/Un Skilledlabour for electric repair/ maintenance / operation of Air conditioning/Air cooling/Fire fighting/Lift/DG set/CCTV/EPABX or any other electromechanical systems as per requirement (one shift of 8 Hrs per day for 26 Working Days in a month)
2Highly skilled Labour
3All in all comprehensive maintenance of various type airconditioners After Defect Laibility Period of Equipment including repair / replacement of compressor, condensing/ cooling coil , refrigerant, piping , fan motor , remote , charging of refrigerant when ever required and periodical servicing as per OEM"s recommendations to meet out the efficient performance of the equipment.
41.5/1.8/2.0 Tr Split type air conditioner
52.2/3.0/3.6/4.2 Tr Floor Standing Tower Type Split AC
6All in all comprehensive maintenance ofWater cooler after Defect Laibility Period of Equipmentincluding compressor, condensing/ cooling coil ,water tank with inner pipingincluding repair / replacement of components , charging of refrigerants when ever required , cleaning , servicing etc as per OEM"s recommendations to meet out the efficient performance of the equipment.
7Water Chiller of capacity 1200 Ltrs/hr cooling Capacity and 500 Ltrs Storage Capacity
8150/400 Ltr to 225/400 Ltr capacity
9150/150 Ltr capacity
10Up to 60/120 Ltr capacity
11Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. (Internal work Exposed on wall)
1232mm nominal outer dia pipes
13P & F Full-way Valve (IS:778 Mark) or wheel valve of approved make : (-do-) 32mm nominal bore.
14Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure "A" attached with this BSR
15Single pole MCB (With B/C curve tripping Characteristics)6 A to 32 A rating
16Four pole MCB (With B/C curve tripping Characteristics)6 A to 32 A rating
17Providing & Fixing of Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick  conforming to IS-8623-1 & 3 /  IEC 61439- 1 & 3. powder painted complete with din rail  making internal DB  terminations with copper lugs,  detachable gland plate, including making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure "A" attached with this BSR
18Suitable for Six / Eight module for MCB/ RCCB
19SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008,& IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 - 440 V ) permanent split capacitor type (PSC), fitted with thermal overload protection, Including cost of hardware etc on existing platform complete. Pump shall have following HP Rating, phase, Head, minimum Discharge respectively complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure "A" attached with this BSR .0.5 HP, 1-Ø, (3 - 18)Mtr, (100-26) LPM
20Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed Un-armoured Coppercable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withelectrolytic gradeCopper made of copper rodsconfirming to IS 613-1964, of purity >99.7 %,Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray (with cable tie) includingtesting etc. as required of following size. OEM must have it"s own in house NABL accrediated Laboratory for testing procedure as per IS:10810 For additional technical parameters of product / work refer Annexure "A" attached with this BSR
214.0 Sq. mm 3 core
22P & F PVC Storage Tank ISI Marked (IS : 12701) indicating theBIS license No),of approved make with cover, 25mm dia 1M long G.I. over-flow pipe & 25 Cm. long wash out pipe with plug & socket, including making connection etc., complete of approved design:2000 litre capacity
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail