| 1 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded \"FR\"PVC insulated & unsheathed single core stranded copper wire (Brand approved by EIC) in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with Modular type switch (Brand approved by EIC)fixed on Modular GI switchboard with top cover plate flushed in wall incl. mending good damages to original finish 9 Mtr. [ 1(iii) / E-20 ] |
| 2 | Distn. wiring in 3 X 22/0.3 (1.5 sqmm) single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wirein 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 6A 5 pin plug point with Modular type plug socket & switch as per GS.On Board [ 3 (i) / E- 20 ] |
| 3 | S & F 240V,2 nos. 16A Plug socket with 2 nos.16A moduler type switch (Brand approved by EIC) on wall incl.S&F 6 module GI box & cover plate incl.making necy.Connection by PVC cu wire as required. |
| 4 | Supply & Fixing 240 V, 3 nos. 6 A, 3 pin Modular type plug socket with 3 nos. 6A Modular type switch (Brand approved by EIC), 1 nos 16 Amp modular type socket and ,1 no 16 Amp modular type switch, 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 5 | Supply & Fixing240 V, 25 A, 3 pin Modular type plug socket(Brand approved by EIC), without plug top and switch with 2 Module GI Modular type switch board with top cover plateflushed in wall and making necy. connections with PVC Cu wire and earth continuity wire etc. [5(a)/ E-17 ][For AC] |
| 6 | Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.[17/E-19] [For AC] |
| 7 | Supplying and fixing 415V, TPN SFU with sheet steel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.(a) 250 Amp on angle iron frame. (Make-L&T/Siemens/ABB)(D-3 4a) |
| 8 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall as per GS.2+14Way[ Legrand/ABB/L&T ][ 13 / D- 9 ] |
| 9 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall as per GS.( Make - Legrand/ABB/L&T )8 Way[ 14 / D- 10 ] |
| 10 | Supplying and fixing double door Vertical TPN MCB Distribution board for MCCB incomer with IP-42/43 protection, on angle iron frame on wallas per GS ( Make - Legrand/L&T/Siemens)12 Way ( Up to 250 A ) [15 /D- 11 ] |
| 11 | 40 A DP [ 6 / D- 5 ] |
| 12 | 63 A FP [ 6 / D- 5 ] |
| 13 | Supplying and fixing 415 V Four Pole MCCB of Breaking capacity 25kA/35kAin existing Vertical DBs including necessary connection as per GS [ Make - Legrand/L&T/Siemens) ]250 A FP [ 10/ D- 8 ] |
| 14 | Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connectionas per GS [ Make -Legrand/L&T/Siemens) ]6-32 A SP[ 7 / D- 6] |
| 15 | 32A TP[ 7 / D- 6] |
| 16 | 63A TP [ 7 / D- 6] |
| 17 | Supplying and Drawing 1.1 KV single core stranded \"FR\" PVC insulated & unsheathed single core stranded copper wire of the following sizes in the prelaid polythene pipe as per GS.2x(2.5 sqmm)+1x(1.5 sqmm) (For Power plug & Computer Plug)[ 1(s) / E-9 ] |
| 18 | 2x(4 sqmm)+1x (2.5 sqmm) (For Split type A.C Machine and Industrial power point )[ 1(v) / E- 9 ] |
| 19 | 2x (6 sqmm) + 1x (4 sqmm) (For TPNDB to SPNDB) [ 1 (y) / E- 9 ] |
| 20 | 3 X 1.5 Sqmm |
| 21 | Supplying and fixing polythene pipe complete with fittings as necy. under ceiling/beam, bound with 22 SWG GI binding wire incl. supplying and drawing 1x18 SWG GI Wire as fish wire inside the pipes and fittings and providing 50 mm dia disc of MS sheet (20 SWG) having colour paint at one face fastened at the load point end of the polythene pipe with fish wire (synchronizing with roof/beam casting work of building construction)13 mm dia 3mm thick Polythene Pipe[1(a)/E-2] |
| 22 | 19mm dia 3mm thick Polythene Pipe[1(b)/E-2] |
| 23 | 25 mm dia 3mm thick Polythene Pipe [1(c)/E-2] |
| 24 | Cutting Channel of size (31 mm x 31 mm)/(40 mm x 40 mm)/(43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 13/19/25 mm, 3 mm thick Polythene pipe by means of anchoringchemical (Hilti/Sika) and GI \"U\" hooks of 8 SWG incl. supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles as per GS.13 mm dia 3 mm thick[ 5(a)/ E- 2 ] |
| 25 | 19 mm dia 3 mm thick[ 6 (a)/ E- 3 ] |
| 26 | 25 mm dia 3 mm thick[ 7 (a)/ E- 3 ] |
| 27 | Making holes on RCC ceiling 125 mm depth having dia of following sizes : 125 mm depth, 50 mm dia[9(b)/E-3] |
| 28 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works100 mm x 100 mm x 65 mm[11(a)/E-4] |
| 29 | 150 mm x 100 mm x 65 mm[11(b)/E-4] |
| 30 | 175 mm x 100 mm x 65 mm[11(c)/E-4] |
| 31 | Supply & Fixing bakelite / perspex top cover on existing switch board by Brass screws after making housing for switch by cutting bakelite / perspex cover and making necessary connections as required100 mm x 100 mm x 65 mm[12(a)/E-4] |
| 32 | 150 mm x 100 mm x 65 mm[12(b)/E-4] |
| 33 | 175 mm x 100 mm x 65 mm[12(c)/E-4] |
| 34 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.1.5 sqmm |
| 35 | 2.5sqmm[9 (i)/F-5] |
| 36 | 4 sqmm [9 (ii)/F-5] |
| 37 | 6 sqmm [9 (iii)/F-5] |
| 38 | Supply of3.5 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / havells / Gloster/RR]3.5 Core 240 Sq. mm [ NS ] |
| 39 | 3.5 Core 300 Sq. mm [ NS ] |
| 40 | Supply of3.5 Core XLPEInsulated & Sheathed Armoured Aluminium Conductor cables for Working Voltage up to 1100 Volts of following sizes [ Make Polycab / havells /Gloster/RR]3.5 Core 35 Sq. mm [ NS ] |
| 41 | Laying of cable above 185 sqmm in underground trenchas per GS for the following numbers of Cables.[ 1(b)/ F- 2 ] |
| 42 | Laying of two cable above 185 sqmm in underground trenchas per GS for the following numbers of Cables.[ 2(c)/ F- 2 ] |
| 43 | Laying of cable upto 35 sqmm through floor/pavment/wallas per GS for the following numbers of Cables.[ 5-i/ F- 3 ] |
| 44 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required.(TATA-M/Bansal/Jindal)65 mm dia |
| 45 | 80 mm dia |
| 46 | Supplying and fixing compression type gland and finishing thoseforfollowing XLPE / PVC armoured cable (2/4 / 3.5)Core as per GS. 4 core 6 sq mm |
| 47 | 3.5 Core 35 sq. mm |
| 48 | 3.5 Core 240 Sq. mm[7(d)/F4 & 8(b) /F5] |
| 49 | 3.5 Core 300 Sq. mm[7(d)/F4 & 8(b) /F5] |
| 50 | Fixing only single/twin fluorescent light fitting inthe ceilingfixed with “L” type MS clamp as per GS [17/C-2] |
| 51 | Fixing only single/twin florescent light fitting complete with all accessories Directly on wall/ceiling as per GS[14(d)/C-2] |
| 52 | Supply of 4ft LED T-8 box type single batten with end cap complete with all accessories [CROMPTON/Havells/Philips]. [NS] |
| 53 | Supply of 4ft LED T-8 box type Twin batten with end cap complete with all accessories [CROMPTON/Havells/Philips]. [NS] |
| 54 | S&F 20W LED T-8 lamp [CROMPTON/Havells/Philips] on fittings. |
| 55 | S & F circular LED,15 watt(CDL/WW),240 volt,surface mounted panel light from ceiling with all accessories incl. interconnection as per direction of EIC (Crompton make cat no LCRP-15-CDL/Phillips / Surya/Havells) |
| 56 | S & F ofLED mirror light of 7 watt,240 volt surface mounted on wall with all accessories incl interconnection as per direction of EIC.(Make-Crompton/Havells/Philips) |
| 57 | Supply & Fixing 240V, Modular Socket (2 Module) type fan regulator (Step type) (Brand approved by EIC) on existing Modular GI switch board as per GS[ 10 / E-18 ] |
| 58 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc as per GS[ 21 (a) / C-3 ] |
| 59 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification as per GS.[ 29/D-14 ] |
| 60 | Fixing only exhaust fan after making holes in wall as per GS(12\") [ 28(b)/C-4 ] |
| 61 | Fixing only wall bracket fan on wall by S &F rag bolts,nuts, & washer (6 mm dia X 62 mm long) or as reqd, incl. S& F 24/0.20 PVC insulated flexble copper wire 0.5 mt. length. |
| 62 | Supply & Fixing GI sheet (20SWG) metal Cowl with MS flat iron frame & GI wire mesh on wall as per GS(12\")[ 33/D-14 ] |
| 63 | Engraving the deptt. number with 10 mm lettering on the body of fan upto 10 letters incl. hifen, stroke or stop[ 24 (a) / C-3 ] |
| 64 | Extra for additional one letter incl. hifen, stroke and stop as per GS[24 (b) / C-3 ] |
| 65 | Painting upto 10 letters of the engraved number with approved black /red paint as required as per GS[ 26 (a) / C-3 ] |
| 66 | Extra painting for additional one letter of the engraved number as per GS[ 26 (b) / C-3 ] |
| 67 | Supply of ceiling fanscomplete with all accessories having the following Model / Cat No.( Make -Crompton Greaves/USHA/As per choice of EIC )a.1200 mmSweep ( Aura / Striker Galaxy/SIMILAR MODEL )[ NS ] |
| 68 | S&F 230V 400mm (16\") Sweep heavy duty wall bracket fan(Make : Orient, Model : Wall 45) 1350 rpm silent in operation with S&F wooden base plate fixed on wall by 4 nos. steel fastener with nut, bolt & washer for fixing the wall bracket fan as per direction of EIC . |
| 69 | Supply of Exhaustfanscomplete with all accessories having the following Model / Cat No. ( Make -EPC )12\"( 300mm ) Speed 920 RPM |
| 70 | S & F of digital Timerfor exhaust fan with 2 pole enclosure.(Make-L&T) |
| 71 | Supply and installation out door type LT Feeder Piller Box ( Cubicle Duplex type) of suitable Sizemade of 5 mm thick M.S . sheetand bottom portion with 10mm thick MS plate rigidly fixed by nuts bolts washers and 50 mm. x 50 mm. x 10 mm angelframeduly welded having suitable nos. of cable entry including cable allay and top portion hut type water shedding arrangement with bothside opening system with two part door ( made of 5 mm. MS . Sheet ) including allan key type lockingand extra pad locking arrangement including supply and fixing2nos 7 leverGodrej lock with triplicate keys at both ends incl. making necessaryinterconnections with suitable length and gauge of copper bar having making hole in both ends withmain switches , BBCs and other components , including providing C . C (4:2:1) base block of suitable size3 ft. depth Under the ground level andandproviding brick foundation of suitable size up to 2.5 ft. Above the ground level incl. necessary plastering (5 : 1 cement morter) and 3 mm. thick neat cement finish having provision of cable entry hole connectionand providing earthing attachment (2 nos)with suitable nuts bolts washers , a seperate earth bus is necessary in lower portion,incl. fill up the cable duct of feeder piller boxwith sand. The piller box should be painted with dry powder paint with 7 tank process. |
| 72 | Metering & indication arrangement should be fixed on enclosure of BBC. The materials & design should be approved by E.I.C before fabrication & erection.The Piller box should be made from CPRI approved manufacturer (at the time of supply CPRI certification is mandetory) and inner portion should be made as like cubical type panel with two side cable Allay with compartmentalised. This feeder piller consisting with the following components : - |
| 73 | A) Incoming- 440V, 630A, L&T make TPN SFU with 3nos 630A HRC fuse ---- 01 set B)500 V, 1000 A. electrolyte grade tinned copper bus barsection of size [4 X (2 X 80 X 5 mm)] for RYBN, & (40 X 5) mm Al. Bar for earth. All bus bar shall be fixed with FRP chair & the entire bars are insulated with PVC heat Sinkable sleeve of suitable size & color as per direction of E.I.C ---- 1 SetC) Outgoing---a) 440V, 160A, L&T make TPN SFU (Open Execution) with 3nons 160A HRC fuse------ 04 set b) 440V, 250A, L&T make TPN SFU (Open Execution) with 3nons 250A HRC fuse------ 02 set |
| 74 | Metering Instrument- a)50- 520 I/P voltage,0.1 /0.5 accuracy class,3 line LED display Multifunction meter (Make-L&T (Cat no-MFM 4405 LED meter CI 0.5 S with RS 485)-1 no b) Current transformer of rating 1000 / 5A Kappa make--- 03 setc)20 Amp. Bakelite fuses base & bridge with 4 Amp. HRC fuse link .(Standard make)--03 setd) R,Y,BLED indicating lamp (L&T)-- 1 set (3 nos)e) S&F Danger board--- 04 nos |
| 75 | Dismantling of existing 1.5 Mt long mini pole from the roof by demolishing the cement concrete, and deposit it in sectional store. |
| 76 | Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paint.(4(a)/H-2)(i) 1st coat of aluminium paint over 1 coat of RO priming (ii) 2nd coat of aluminium paint over 1st coat |
| 77 | Fixing only 80mm dia 1.5Mt long mini GI pole [TATA-M]including providing cement concrete(6:2:1) muffing around pole of dimension 2’-6 X2’-6”X2’-0” above roof level with cement mortar plastering and neat cement finish. Including S/F 8”X6”X4” GI loop box which contains one 5 Amp Fuse and one 4 way terminal with 4pole Bakelite stud&40mm dia alkathanepipe for cable entry as per GS.[N/S] |
| 78 | Wiring with 2X 1.5 Sqmm PVC copper wire in 13mm diapolythene pipe from loop box to LED fitting. (average run 4mt) [N/S] |
| 79 | S&F 4 core 6 Sqmm PVC insulated & sheathed unaurmored cable by saddling on wallwith earthing attachment of 10 SWG GI wire(Hot Dip),wire making holes etc .[N/S] |
| 80 | S&F 72 W LED out door luminaire on arm bracket. [ CROMPTON GREAVES make NEXUS cat no LSTP-72-CDL-A/Havells/Philips][N/S] |
| 81 | Supplying & Fixing 240 V AC/DC superior type Multitune Call Bell (10 nos tune) (Anchor) as per GS[ 20( a )/D-13 ] |
| 82 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings as per GS65mm dia [11(e)/F-6] |
| 83 | Supplying & fixing earth busbar including Connecting the equipments of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall as per GS[4(a)/G-2 ] |
| 84 | Excavation of soil for installation of Earth Electrode and filling & ramming.For Morrum Soil [ 1(b)/G-1 ] |
| 85 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. Long With TATA-Medium GI pipe as per GS [ 2(a)/G-1 ] |
| 86 | S&F Sign board of ACP base on MS structure, Acrylic letter with embeded LED of approximate size 4ftX 10ft SITC of LED Sinage Board with liquid Acrlyic letters on ACP Board of 3 mm Thick (Make Aludecor/ Alstone) of size 4 ft. x 10 ft or other suitable size to accommodate all the matters / contains as approved by the authority to be made with 25 x25 x 4 mm M.S angle Iron, 18 S W G squrae/ Round Hollow bar. Base plate (10mm Thickness) required for fixing the necessary Nuts. Bolts Washers supporting angle Iron, Clamp etc and ACP Sheet on all sides to be moulded uniformly, Side fabricated by Aluminium \"L Channel upon which elevated or box type letter made from imported liquid acrylic will be fixed. The Thickness of Acrylic will be 5 mm (for small letters). 8mm (for Big letters) and 10 mm (for very big letters). The Back Side of the letters is covered by 3 mm thick ACP (Make- Aludecor/Alstone) or Branded WPC Board. The inside of the letter Supplying and Fixing of best Quality LED Lighting arrangement of fully water proof IP67 Zig-Zag strip made of LED module (Phillips or approved make) 100 Lumen/watt( containing 54 LED per Mt. & 9W/Mt.) to be Fixed in proper arrangement with necessary inter connection. The letters are sealed by exterior grade |
| 87 | SITC of 1.8/2/2.2 Ton split type A.C.machime having the following specification & feutures a) Cooling capacity nominal (BTU /HR): 24000 b) Star Rating -5/3 srarc) Rated Voltage-220 V + / -5%, Frequency -50 Hzd) Compressor type- Rotarye) Mini. Room Discharge Air Flow Rate-28 CM/minf) Refrigrant: R-410Af) Cordless Remote Arrangement with all modernized provision of temperature setting , Fan speed option ( Low. Medium /High ) Auto Swing incld 3mtr incoming wire cable & plug 16 A Top & outer wall angle base for outdoor unit.[Make :- MITSUBISHI Heavy, model SRK25CSS-S6/ SRC25CSS-S6) / Daikin/O-General) [N.S] (Brand as per choice of EIC) |
| 88 | S&F 15.88mm&6.35mm copper pipe with keno foam insulation & 3core 2.5Sqmm & 4core 1.5Sqmm copperun aurmoredcable. [ for connection of plug socket to out door unit & out door to indoor unit][N/S] |
| 89 | S&F 15mm PVC flexible drain pipe.[N/S] |
| 90 | Supply & Installation of suitable size iron grill protection(cage) for outdoor unit of 1.5/2.2 Ton Split type A.C. Machine incl. 5 liver Godrej Novtal Lock incl. painting. |
| 91 | S & F of suitablesize single phase timer box on wall with locking arrangement & DIN Rail consisting of following items incl. necy. inter connection by suitable size of stranded PVC insulated 1.1 kV Gr.Cu wire after crimping as per direction of EIC (A) Double door (2+8) way SPNDB with IP 42/43 protection (Make:Crabtree/Siemens/ABB/Hager) - 1 No.(B) Digital timer having provision of adjustment 24 hour (Make : L&T/GIC/GE/Legrand/ABB/Hagger) - 1 No. (C) 250 V magnetic coilwith DP 32A power contactor having 2 NO & 2 NC Contact (Make : L&T/Siemens/Havells/Legrand/ABB/Hager)- 1 No(D)250V 25/32A 10kA,DIN mounted DP MCB \"C\" curve (Make : Legrand/Siemens/ L&T/ Schneider/ABB /Hager) -1 No (E) One no.red and one no.green 240V LED indicator for indicating Auto & bypass indication(Make : L&T/Kaycee/ABB) - 1 Set(F) Toggle Switch - 1 Set (G) Locking arrangement and two way malamine terminal - 1 No. |
| 92 | S & F lightning conductor Air-terminal made of 15 mm dia 1500 mm long GI pipe (ISI Medium) having five prongs of 4SWGGI (Hot Dip) wire at top with 85 mm dia 6 mm thick GI base plateat bottom icl. Necessary holes etc. duly grouted on the parapet etc. in CC mortar (4:2:1) |
| 93 | S & F(Hot Dip) strips 25mm x 6 mm thick for vertical run on wall for lighting conductor with existing post insulator spaced not exceeding 500 mm apart incl. mending good the damages to building work.wire at top with 85 mm dia 6 mm thick GI base plateat bottom ibcl. Necessary holes etc. duly grouted on the parapet etc with 4 nos fastnut. |
| 94 | S & F(Hot Dip) strips 25mm x 6 mm thick for parapet / roof/ horizontal run/ plinth surface on wall for lighting conductor with existing post insulator spaced not exceeding 500 mm apart incl. mending good the damages to building work.wire at top with 85 mm dia 6 mm thick GI base plateat bottom ibcl. Necessary holes etc. duly grouted on the parapet etc with 4 nos fastnut. |
| 95 | Earthing with 65 mm dia GI pipe 3.64 mm thick X3.04 mtr. Long and 1 x 40 x 6 mm GI (Hot Dip) strips(4mtr.) long 13 mm dia X.80mm long GI nut, bolt, Washer incl. S & F 50 mm dia GI/ HD PVC pipe protection (1 mtr.) longto be filled with bitumen partly under the ground levelandpartly above ground level driven to an average depth of 3.65 mtr. below the ground level. |
| 96 | Excavantion of soft soil for install. Of earth, electrode and filled incl. ramming the same properly. |
| 97 | S & laying 50 mm dia GI pipe protection in UG Trench, different drain for 40 mm x 6 mm GI Flat. |
| 98 | S & fixing earth busbar of galvanized (Hot Dip) MS flat 50 mm x 6 mm on wall having clearance of 6 mm from wall incl. providing drilled holes on the busbar complete with GIbolts, nuts, washers, spacing insulators etc. as per GS. |
| 99 | Treatment of soil by using salt& charcoal or coke for pipe earthing. |
| 100 | Cutting cornices/steps etc. incl. recess in building etc. & supply & fixing 32 mm bore(ISI -Medium) GI pipe protection as below and mending good damages to the building works----a) Length upto 2 mtr. As require |
| 101 | Making solderd joint between GI stripes and airterminal and other metallic objects incl. supplying of jointing materials with two nos 8 mm dia and 3/4 th length nut bolt of same matrerials with contact grease and painting with 2 coats of bituminous paint. |
| 102 | Supply and Fixing of poceline post insulator(SP65 of ASIAN Electrical and Electronics) suitable for passing for earth conductor (as approved by EIC) with two nos of screw on wall and suitable arrange ment for fixing of earth continuty flat. |
| 103 | Hiring charges for scaffolding arrangement incl dismantling at theend ofwork and carriage for LC installation of vertical run. |
| 104 | Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe |
| 105 | Supply, Installation, Testing & Commissioning of Microprocessor controlled. IP Addressable Multi-sensor detector IP 54 (VDS / UL /ERTL/ LPCB / FM approved) with inbuilt optical smokeSensors and heat detector sensor with inbuilt short circuit fault Isolator as per NFPA style 7 wiring complete with base (Note Detectors without built-in fault isolator is also acceptableProvided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. Thedetector should have 360 degree optical view with single/ multiple LED that blinks on actuation of detector. Reverse polarity or faulty zone wiring shall not damage the detectors. (Approved Make : Cerberus Pro / Johnson Controls/ Edward/ Secutron /Honeywell/ Apollo/ Morley/ Eaton/GST/ Ravel) |
| 106 | Supply, Installation, Testing & Commissioning of Microprocessor controlled IP Addressable Heat detector IP 54 ( VDS / UL/ ERTL / LPCB / FM approved ) with combination of fixed type &Rate of Rise of Temperature feature. Detector shall have minimum triggering temperature programmable from 6O deg. C to 80 deg. C., having high level of immunity to electromagnetic influences and show alarm signal limit temperature is reached. Detector shall have inbuilt short circuit fault isolator as per NFPA style 7 wiring complete with base (Note : Detectors without built-in fault isolator is also acceptable provided one independent short circuit fault isolator per detector is to be provided extra without extra cost) the detectors should have built in response indicator with LED indicator. (Approved Make : Cerberus Pro / Johnson Controls/ Edward/ Secutron /Honeywell/ Apollo/ Morley/ Eaton/GST/ Ravel) |
| 107 | Supply, Installation,Testing & Commisioning of Addressable Manual Call break Point( VDS /UL / FM / ULC approved ) with in built fault isolatoras per NFPA style 7 wiring complete asrequired (Note : MCP without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group ofaddressable devices, Numbers of addressable devices in a group will be as per latest recommended standards of IS-2189without any additional cost).(Approved Make : Cerberus Pro / Johnson Controls/ Edward/ Secutron /Honeywell/ Apollo/ Morley/ Eaton/GST/ Ravel) |
| 108 | Supply, Installation, Testing & Commissioning of AddressableHooter ( sound output of minimum 90 db )cum strobe (strength of light 10 cd)complete with inbuilt isolator(Note : Hooter Cum Storbe without built-in fault isolator is also acceptable but in such case the contractor shall provide one independent fault isolator module for every group ofaddressable devices, Numbers of addressable devices in a group will be as per latest recommended standards of IS-2189without any additional cost). ( VDS / UL / FM / ULC approved) approved.(Approved Make : Cerberus Pro / Johnson Controls/ Edward/ Secutron /Honeywell/ Apollo/ Morley/ Eaton/GST/ Ravel) |
| 109 | Supply, Installation, Testing & Commissioning of Microprocessor based intelligent, addressable and network connected Repeater panel ( VDS / UL /ERTL/ LPCB/ FM approved), should have all the controls and monitoring as on the main fire alarm panel, functioning as a controller, shall allow remote command in the system reset, trouble and alarm silence and manual alarm. It sha1l be programmable to display information for the entire system i.e. all panels in the network, having minimum Bo characters LCD display (display system status). The system text displays shall include: Alarm missing point trouble; system test, service, local system test, extra custom test by polling circuit and address. The repeater panel should annunciate alarm and trouble conditions in the occasion of signal actuation. (Approved Make : Cerberus Pro / Johnson Controls/ Edward/ Secutron /Honeywell/ Apollo/ Morley/ Eaton/GST/ Ravel) |
| 110 | Supply, Installation, Testing & Commissioning of Monitor Modules (VDS / UL /ERTL/ LPCB/ FM approved) for monitoring Flow switches / Fire exit doors / AHU / Lift etc. with inbuilt short circuit fault isolator and minimum (04) four potential free contract with adjustable setting parameter likes of Input or output, complete in single or multiple housing with degree of protection IP 54 with flash LED indicator that conforms module is operational and integrated buzzer signaling maintenance alarm, complete as required. (Approved Make : Cerberus Pro / Johnson Controls/ Edward/ Secutron /Honeywell/ Apollo/ Morley/ Eaton/GST/ Ravel) |
| 111 | Supplying, installation, testing and Commissioning of LED type Response indicator (VDS / UL /ERTL/ LPCB/ FM approved) having 2 Nos. red colored LED lamps including connections etc.(Approved Make : Cerberus Pro / Johnson Controls/ Edward/ Secutron /Honeywell/ Apollo/ Morley/ Eaton/GST/ Ravel) |
| 112 | Supply & Laying of 2 Core 1.5 sq.mm FRLS copper Cable (For Loop) (Make. Finolex / Polycab / Havells/ RR ) with 20 mm NB PVC rigid conduit pipe (Make: Precisson-Medium / Polycab) on the surface of the wall. |
| 113 | Supply, Installation, Testing & Commissioning of Microprocessor based addressable fully networkable fire alarm control panel (VDS / UL /ERTL/ LPCB/ FM approved) suitable for the devices as stated in the previous items of this BOQ along with 20% spare capacity with each loop loading not exceeding Boo/o of the full capacity of detectors and devices taken together, complying to IS 2189:2008 or its latest amendments, and with minimum 600 character alpha - numeric liquid crystal display The panel shall be soft addressable type and shall be able to give pin point location of all fire/ fault conditions. Further, the panel must be able to automatically switch off respective control switches with help monitor module whenever any alarm is triggered. The Panel should be able to store sufficient numbers of log events in its Memory as per recommended standards. The panel should have extra loop card slot for expansion of capacity twice. The panel shall have in built rectifier, provision for external & internal printer ( if required ), Loop cards, L C D unit to indicate Fire/Fault Signal with address and analog output, complete in all respects, inbuilt Surge protection facility, integral SMF lead acid batteries with sealed cells of 24V capable of running for 24 hours normal working and then be capable of operating the system for 60 minutes during Emergency condition, with integral battery charger complete in all respect as required. The FACP shall be capable of being networked (future expansion) with other similar FACP located at different part of the premises through single RS 485 modbus.The FACP shall have provision for interfacing with the public address system, remote computer and BMS interface. The system must be preloaded with licensed software. (Approved Make : Cerberus Pro / Johnson Controls/ Edward/ Secutron /Honeywell/ Apollo/ Morley/ Eaton/GST/ Ravel) |
| 114 | TESTS :- 1) The system shall be tested and commissioned by a qualified competent, trained engineer or technician authorized by the manufacturer of the fire alarm equipment to technicallysupervise and participate during all of the adjustments and tests for the system. 2) Before energizing the cables and wires, inspection and check for correct connections, and test for short circuits, ground faults, continuity, and insulation and other tests as perapplicable Indian/ International standards must be done. |
| 115 | TERMS & CONDITIONS:- The Agency must procure the materials from the Manufacturer / OEM or from their authorized sales channel so that the standard warranty / support of the Manufacturer / OEM becomes applicable to the products to be delivered and installed by them. Documents that authenticates such procurement from the Manufacturer / OEM or from their authorized sales channel and standard warranty / support should be sent from the e-mail of the Manufacturer / OEM / authorized sales channel to the email of Engineer-in-Charge and hard copy of it to be submitted during execution, of work/ submission of bill. If any refurbished material is supplied and installed, penal action will be taken as per existing rules |
| 116 | Note:- Labour welfare Cess @ 1% and GST @ 18% on Bill amount will be deduct. |