}

Construction Of Pds Bhawan To Ajgurh Road Pondi-Iii Length 9.50 K.M. Under Sub Division Chitrangi C, singrauli-Madhya Pradesh

Public Works Department-PWD has published Construction Of Pds Bhawan To Ajgurh Road Pondi-Iii Length 9.50 K.M. Under Sub Division Chitrangi C. Submission Date for this Tender is 11-10-2022. Road Work Tenders in singrauli Madhya Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34104620
Construction Of Pds Bhawan To Ajgurh Road Pondi-Iii Length 9.50 K.M. Under Sub Division Chitrangi C
Open Tender
Indian
Madhya Pradesh
singrauli
11-10-2022

Tender Details

Construction Of Pds Bhawan To Ajgurh Road Pondi-Iii Length 9.50 K.M. Under Sub Division Chitrangi C

Key Value

Document Fees
INR 20000 /-
EMD
INR 867560.0 /-
Tender Value
INR 8.67 Crore /-

BOQ Items

Name of Work: N.I.T. Shedule ForConstruction of PDS Bhawan to Ajgurh Road Pondi -IIILength 9.50 km. Sub Division ChitrangiDistt- Singrauli (M.P.) .@ PWD Road & Bridge SOR w.e.f 25.03.2022
Sl. No. Item Description
1Laying and Jointing PVC Pipe. Heading Clearing and Grubbing Road Land Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 mm in thicknesse
2Surface Drains in Soil Construction of unlined surface drains of average cross sectional area 0.40 sqm in soil to specified lines, grades, levels and dimensions to the requirement of clause 301 and 309. Suitable Excavated material to be used in embankment within a lead of 50 metres as per relevent clauses of section-300.
3Excavation in Soil using Hydraulic Excavator and Tippers with disposal upto 1000 metres. Excavation for roadwork in soil with hydraulic excavator including cutting and loading in tippers, trimming bottom and side slopes, in accordance with requirements of lines, grades and cross sections, and transporting suitable earth to the embankment location and disposing off unsuitable earth with all lifts and lead upto 1000m as per relevent clauses of section-300 of specification..
4Construction of Embankment with Material Deposited from Roadway Cutting Construction of embankment with approved materials having CBR>7 deposited at site from roadway cutting and excavation from drain or foundation of structures graded and compacted to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300.
5Embankment Construction with Material Obtained from Borrow Pits Construction of embankment with approved material having CBR>7 obtained from borrow pits with all lifts and leads, transporting to site, spreading, grading to required slope and compacting to meet requirement of table 300-1, 300-2 and as per relevent clauses of section-300.
6Crusher Run Macadam Sub Base/Base Course Providing crushed stone aggregate, depositing on a prepared surface by hauling vehicles, spreading and mixing with a motor grader, watering and compacting with a vibratory roller as per clause 410 to form a layer of sub-base/Base in accordance to Table No. 400-14, 400-15 and as per clause of section 407 of specifications (ii)For 37.5 mm maximum size
7Wet Mix Macadam Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at OMC in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density in accordance to Table No. 400-12, 400-13 and as per clause of section 406 of specifications. Construction of Shoulders with approved material/selected soil i/c excavation all lifts & leads i/c grading to required slope & camber of 4% and compacting using vibratory roller of 80 to 100kN static weight to meet requirement as per relevant clause of 400.
8B Hard Shoulders (CBR value >12).
9Prime coat Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including clearing of road surface and spraying primer at the rate of 0.75 kg/sqm using mechanical means as per clause 502 of specifications Providing and applying tack coat with catonic bitumen emulsion (RS-1) using emulsion pressure distributor on the prepared bituminous/granular surface cleaned with mechanical broom and as per relevant clauses of section-503 of specifications.
10(ii) @0.30 kg per sqm (dry & hungry bituminous surfaces /granular surfaces treated with primer) Dense Graded Bituminous Macadam Providing and laying dense bituminous macadam using crushed aggregates of specified grading, premixed with bituminous binder @ 4.0 to 4.5% by weight of total mix of mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per clause 505 of specificat
11Bituminous Macadam Providing and laying bituminous macadam using crushed aggregates of specified grading premixed with bituminous binder, transported to site, laid over a previously prepared surface with Electronic Sensor paver finisher to the required grade, level and alignment and rolled as per clauses 501.6 and 501.7 to achieve the desired compaction and as per clause 504 of specifications. b) Using Drum Mix Plant of appropriate capacity. (ii) for GradingII(19 mm nominal size) bitumen content 3.5% with bitumen 60/70 (VG 30)
12Open - Graded Premix Surfacing Providing, laying and rolling of open - graded premix surfacing of 20 mm thickness composed of 13.2 mm to 5.6 mm aggregates either using penetration grade bitumen or cut-back or emulsion to required line, grade and level to serve as wearing course on a previously prepared base, including mixing in a suitable plant, laying and rolling with a smooth wheeled roller 8-10 tonne capacity, finished to required level and grades all complete as per clause 510 of specification. (i) Case - I: Mechanical method using Penetration grade Bitumen VG 30 and HMP of appropriate capacity not less than75 tonnes/hour.
13Seal Coat Providing and laying seal coat, sealing the voids in a bituminous surface laid to the specified levels, grade and cross fall using Type A and B seal coats, all complete as per clause 511 of Specification. (ii) Case - II : Type B (Providing and laying of premix sand seal coat using HMP of appropriate capacity not less than 75 tonnes/ hours using crushed stone chipping (aggregate shall pass 2.36mm seal and retained to 180 micron sieve) and penetration bitumen VG 30 of suitable grade all complete as per clause 511 of specification.
14Retro- reflectorised Traffic signs Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8 of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall be screen printed on high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 10 years warranty for Retro Reflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor. Note:- Manufacture name and date of manufacture is to be printed (Embossed) at the backside of the board. i) 90 cm equilateral triangle
15ii) 60 cm equilateral triangle
16iii) 60 cm circular
17iv) 80 mm x 60 mm rectangular
18v) 60 cm x 45 cm rectangular
19(i) Single Row for one utility service metre
20Excavation for Structures Earth work in excavation of foundation of structures as per drawing and technical specification, including setting out, construction of shoring and bracing, removal of stumps and other deleterious matter, dressing of sides and bottom as per relevant clauses of section 300 & 2100 in 1.Ordinary soil ( including back filling with approved material) (i) Depth upto 3 m
21Guard Stone Providing and fixing guard stones 220x220x1000mm made of hammer dressed stones or 250 mm (dia) x 1000 mm M-15 concrete and fixed 400mm into the ground in moorum and broken aggregates block of size 500x500x500 mmand given two coats of paints with white and black bands i/c excavation etc. complete. On curves or at any other places ad directed by engineer incharge
22vi) 60 cm x 60 cm square
23vii) 90 cm high octagon
24Direction and Place Identification signs more than 0.9sqm size board. Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign board as per IRC 67-2012 made of high intensity Micro-Prismatic Grade Sheeting (Type XI) vide IRC: 67:2012 clause 6.7.3.2 and clause 801.3.3 of MoRT&H fixed over Aluminum composite material sheet with thermoplastic core of Low density polyethylene (LDPE) between two thick skins/sheets of aluminum with overall thickness of 4mm and aluminum skin of thickness 0.3 on both side, the ACM shall conform to Table 6.1 of IRC:67:2012 and Table 800-1 of MoRT&H specification and High Intensity Micro Prismatic Grade Sheeting shall conform to Table 6.6 of IRC:67:2012 and Table 800-3 of MoRT&H specification of in the clause IRC 6.8of the IRC 67-2012 and clause 801.3.7 of MORTH message legend numerical letter etc. and borders shall bescreen printedon high intensity micro prismatic sheeting shall conform to clause 801.3.7 with digital printing ink or of cutout from transparent durable overlay or cutout from the same type of reflecting sheeting for cautionary/ mandatory/ signs, supported on MS sign post of size 75mm x75mm x 6mm of 3.60 meter over all length and fix to ground by means of properly designed foundation of dimension 450x450x600mm with M20 grade concrete. The ACM sheet shall be fixed to the post with four minimum four number breakaway bolts. & supported with a back support frame of 25mmx25mmx3mm angle. 10 years warranty for RetroReflection Sheeting to be provided from the original sheeting manufacture as per clause 6.9 of IRC: 67:2012 & a certified copy for three years for outdoor exposure report from an independent test lab as per clause 6.7 of IRC: 67:2012 for the product offered shall be submitted by the contractor.
25PCC M-15 in Foundation Plain cement concrete M-15 mix with crushed stone aggregate 40 mm nominal size mechanically mixed, placed in foundation and compacted by vibration including curing for 14 days. as per MORT&H Specification 409.
26Providing P.C.C. M-15 Nominal mix for hume pipe culverts in foundation and sub structure etc. as per drawing and as per relevant clauses of section 1500, 1700, 2100 and 2900.
27Providing Plain cement concrete M-15 nominal mix in foundation as per relevant clauses of sections 1500, 1700 and 2100.
28(A) ProvdiingandlayingPlain/Reinforcedcementconcreteinopenfoundationincludingformworkshutteringetc. complete as per drawing and technical specifications and as per relevant clauses of sections 1500, 1700 & 2100 with . PCC GRADE M20
29(A) 1000 mm dia Laying Reinforced Cement Concrete Pipe NP 4 /prestrssed concrete pipe on first class bedding in double row. Providing and Laying Reinforced cement concrete pipe NP4/prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in double row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets.
30A. 1000mm dia Providing and Laying Reinforced cement concrete pipe NP4 / prestrssed concrete pipe for culverts on first class bedding of granular material (cost of bedding included) in triple row including fixing collar with cement mortar 1:2 but excluding excavation, protection works, backfilling, concrete and masonry works in head walls and parapets and as per relevant clauses of section-2900.
31Supplying,fittingandplacingun-coatedHYSDbar reinforcementinfoundationcompleteasperdrawingand technical specifications and as per relevant clauses of section 1600
32Plain/Reinforced cement concrete in sub-structure complete as per drawing and technical specifications. B PCC Grade M20
33F RCC Grade M-25
34Supplying, fitting and placing HYSD bar reinforcement in substructure complete as per drawing and technical specifications and as per relevant clause of section 1600
35Providing and Placing Reinforced/Prestressed cement concrete in super-structure e/x reinforcement as per drawing and Technical Specification and as per relevant clauses of sections 1500, 1700 and 2300 in B RCC Grade M25
36Supplying, fitting and placing HYSD bar reinforcement in super- structure complete as per drawing and technical specifications as per relevant clauses of section 1600FE 500
37Providing and laying Cement concrete wearing coat M-30 grade including reinforcement complete as per drawing and Technical Specifications and as per relevant clauses of sections 1500, 1700 and Clause 2702 of specifications..
38A Providing Back filling behind abutment,wing wall and return wallwithGranularMaterialcompleteasperdrawingand Technicalspecificationandasperrelevantclauses305of specifications and as per appendix 6 of IRC-78
39Providing weep holes in brick masonry/plain/reinforced comcrete abutment, wing wall/return wall with 100 mm dia AC pipe, extending through the full width of the structure with slope of 1 V : 20 H towards drawings foce.Complete as per drawing and technical specification.
40Filler joint (ii)Providing & fixing 20 mm thick compressible fibre board in expansion joint complete as per drawing & Technical Specification
41Providing and fixing in position bituminous paper bearing for slabs as per approved drawing and confirming to IS:1398.
42Construction of RCC railing of M30 Grade in-situ with 20 mm nominal size aggregate, true to line and grade, tolurence of vertical RCC post not to exceed 1 in 500, centre to centre spacing between vertical post not to exceed 2000 mm, leaving adequate space between vertical post for expansion, complete as per approved drawings and technical specifications and as per relevant clauses of sections 1500, 1600, 1700 and clause 2703 of specifications (as per MoST specification drawing SD/201 or SD/304)
43(A) Boulder laid dry without wire crates.
44Kilo Metre Stone Reinforced cement concrete M15grade kilometre stone of standard design as per IRC:8-1980, fixing in position including painting and printing etc (i)(i) 5th kilometre stone (precast)
45iii) Ordinary Kilometer stone (Precast)
46(iii) Hectometer stone (Precast
47Metal Beam Crash Barrier Type - A, "W" : Metal Beam Crash Barrier (Providing and erecting a "W" metal beam crash barrier comprising of 3 mm thick corrugated sheet metal beam rail, 70 cm above road/ground level, fixed on ISMC series channel vertical post, 150 x 75 x 5 mm spaced 2 m centre to centre, however 5 spaces of 600mm each between vertical post and 5 spaces of 900mm each between vertical post will be kept adjacent to RCC parapet/ concrete crash barrier in accordance to figure 9.14 of the IRC-SP: 73-2018, 1.8 m high, 1.1 m below ground/road level, all steel parts and fitments to be galvanised by hot dip process, all fittings to conform to IS:1367 and IS:1364, metal beam rail to be fixed on the vertical post with a spacer of channel section 150 x 75 x 5 mm, 330 mm long complete as per clause 811) and treatment for metal beam cresh barrier on approach shall be modified eccentric loader terminal arrangement as shown in figure 9.12 of IRC- SP : 73-2018 End portion of metal beam crash barrier shall be flared outside by 1.25 mtr. Distance in last section of 8 mtr. Length. Departure side it shall be trailing terminal (TT) arrangement as shown in figure 9.13 of the IRC SP-73- 2018. End portion of metal beam crash barrier shall be flared outside by 0.35 mtr. Distance in last section of 8mtr. length
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail