Rural Development Government Departments Closing in 0 days TDR #34094962

Retrofitting Of Pipe Water Supply Scheme Basar Tal Sakri Dist Dhule

Issued by Government Departments · basar, Maharashtra
Tender Value
26.24 Lakhs
Estimated cost
Bid Submission
03 Oct 2022
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
basar → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Retrofitting Of pipe water supply Scheme Basar Tal Sakri Dist Dhule

BOQ

Name of Work : Under Jal Jeevan Mission Programme BASAR Water Supply Scheme Tal.SAKRI, Dist.DHULE
Sl. No. Item Description
1PART A) BASARS.W. No. 01:- DEEPNING OF SUPPLY WELLItem No.1 :- Excavation in general in hard material comprising of soft rock, hard rock, Manjara rock, etc, by blasting / controlled blasting, chiselling as required in wet or dry condition for Head Works i.e. Intake Well, Connecting Pipe, Jack Well, Pump House, supply Well, etc. for lift 0 to 1.5 M and lead of 150 M including baricading, guarding, disposing off surplus excavated stuff within a radius of 0.5 km. as directed by Engineer-in-charge, excluding refilling. Lift 16.00 to 16.50 m
2Lift 16.50 to 18.00 m
3Lift 18.00 to 19.00 m
4Item No.2 :-Dewatering the excavated trenches and pools of water in the building trenches / pipeline trenches, well works by using pumps and other devices including disposing off water to safe distance as directed by Engineer-in-charge (including cost of machinery, labour, fuel), etc. complete.
5Item No.4:-Drilling of Horizontal Bore 150 mm Dia.By DTC Machine including Transportation of machine at work site etc comp. As per GSDA Rate
6Item No.8:- Carrying out recuperation / yeild test for ascerting the discharge of constructed well / excavated profile as direrted by Engineer in charge.The test carried out by drawing down water from the well/ profile below normal / subsoil water level upto full depth rise in water level is recorded. The normal water level / subsoil water level in the well / profile as well as strainer / suction level at pump as per design of W.S. scheme shall be recorded prior. to the test including cost of all materials.overhead,labours etc. completed as directed.
7S.W. No. 02:-CONSTRUCTION OF SWITCH ROOM (3.0 X 3.0 X 3.0 M) Item No.1 :- Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 m. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 m.) By Mechanical Means
8Item No.2:- Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 cm to 20 cm thick including hand packing and compacting etc. complete.
9Item No.3:- Filling in plinth and floors / trenches with contractor’s murum for bedding in 15cm to 20cm layers including watering and compaction complete.
10Item No.4:- Providing and laying in situ 1:3:6 (M-100) grade of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering from work, compacting and curing, finishing etc. complete with initial lift of 1.50m below / above ground level.
11Item No.5:-Providing and casting in situ C.C. of trap/ granite/ quartzite/ gneiss metal of approved quality for RCC work as per detailed drawings and designs or as directed by Engineer-in-charge including normal dewatering, centering, from work, compaction, finishing the formed surface with CM 1:3 of sufficient minimum thickness to necessary or roughening if special finish is tobe provided and curing etc. complete. (By weigh batching and mix design for M-250 and M-300 only. Use for L&T, ACC, Ambuja, Birla Gold, Manikgad, Rajashree etc. cement is permitted excluding M.S. or Tor reinforcement)For RCC M-200 grade slabs / Landings / Vertical Walls/ Waist Slabs / Steps for Staircase.A) R.C.C FOOTING
12B) R.C.C. Column
13C) R.C.C. Beam
14D) Chajja
15E) R.C.C. Slab
16Item No.6:- Providing and fixing in position steel bar reinforcement of various diameters for RCC piles, caps, footings, foundation, slabs, beams, columns, canopies, staircases. newels, chajjas, lintels, pardies, copings, fins, arches, etc. as per detailed designs, drawings and schedules; including cutting, bending, hookingthe bars, binding with wires or tack welding and supporting as required, etc. complete. (including cost of binding wire)
17Item No.7:-Providing second class Burnt Brick masonry with conventional/ I.S. type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
18Item No 8 :- Providing and fixing rolling shutter fabricated from steel laths of minimum thickness 0.9 mm with lock plate of 3.15 mm thickness reinforced with 35 x 35 x 5 mm angle section fitted with sliding bolts and handles for both sides, deep M.S. channel section of depth and thickness not less than 65 mm and 3.15 mm respectively with hold fast arrangements, M.S. Bracket plate 300 x 300 x 3.15 mm minimum size and shape with square bar, suspension shaft of minimum 32 mm diameter, hood cover of M.S. sheet not less than 0.9 mm thickness and of any size at top and safety devices including mechanical gear operation arrangement consisting of worm gear wheels and worms of high grade cast iron or mild steel and one coat of red lead primer etc. complete. (I.S. 62481979) (Without mechanical gear)
19Item No 9 :- Providing and fixing steel window of various sizes as per detailed drawing without hot dip zinc coating, without ventilators, including fabricating / glazing with plain / obscured glass panels of approved type and quality, iron oxidised fixtures and fastenings, finishing with oil painting two coats complete (with guard bars 12 mm square at 10 cm c/c.)
20Item No 10 :- Providing internal cement plaster 20mm. thick in Single coats in cement mortar 1:3 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete.
21Item No 11 :- Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 mm thick in cement mortar 1:4usingwaterproofingcompoundat 1Kilogramper cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 mm thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete.
22Item No 12 :- Providing and laying cement concrete flooring 50 mm thick with M15 cement concrete laid to proper level and slope in alternate bays including compaction filling joints, marking lines to give the appearance of tiles of 30cm x 30cm or other size laid diagonally/ square etc finishing smooth (with extra cement) in any colour as directed and curing etc. complete.with Crushed sand VSI Grade
23Item No 13 :- Providing and applying washable oil-bound distemper of approved colour and shade to old and new surfaces in two coats including scaffolding, preparing the surfaces. (excluding the primer coat.) etc. complete.
24Item No 14 :- Providing and applying white-wash in two coats on old / new plastered or masonry surfaces and asbestos cement sheets including scaffolding and preparing the surface by brushing and brooming down etc. complete.
25Item No 15 :- Providing and applying two coats of exterior acraylic emulsionpaint confirming to corresponding I.S. of approved manufacture and of approved colour to the plastered surfaces including cleaning ,preparing the plaster surface, applying primer coat ,scaffolding if necessary , and watering the surface for two days etc complete.
26Item No 16:- Providing internal & external electrification of switch room including cost of all material & labour shown in rate analysis etc. complete.
27S.W. No. 03:- Pur Water Pumping Machinery (7.5 HP 1W +1S)Item No.1: - Providing, errecting and giving test of submersible Pump set confirming to I.S. 8034 and motor confirming to I.S. 9283 with water proof wiring, pump shall be suitable for 64m delivery head and discharge of 4.90 LPS with stainless steel shaft, motor suitable for working 415V(+/-) 10%, 3 Phase, 50 Hz AC supply with cable guard, thrust carbon bearing to withstand entire hydraulic thrust. The pump shall be suitable for direct coupling with suitable suction, straining pump should have suitable discharge outlet as per manufacturers design. Stream lined non return valve shall be provided with pump, 3m submersible copper conductor cable and 2 pair of erection clamps, 80mm width, 150mm Dia thick shall be provided with each pump.7.5 HP Submersible Pump Set
28Item No.2:-Providing ISI mark G.I. pipe of following class and dia.excluding GST levied by GOI and GOM in all respect including inspection charges, transportation to stores, etc. complete as per IS-1239/2004. 65 mm Dia.
29Item No.3: - Providing & fixing of M.S. clamps for holding 80 mm dia G.I. pipe.
30Item No.4:- 3 core PVC insulated, PVC sheathedcopperconductor flat submersible cable Supplying and erecting, Flat flexible submersible cable with, Copper Conductor, PVC insulated, and PVC sheathed.(3 core 10 sq mm)
31Item No.5:- Supplying & erecting G.I. pipe ‘A’ class 25 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
32Item No.6:- Making trench in soft soil of suitable width & depth for laying provided L.T cable up to 10 sq.mm complete.As per specification No. CW-EXN-CTR
33Item No.7: - Supplying and erecting DOL starter to operate squirrel cage induction motor working on 380- 440 Volt, 3 phase, 50 Hz with no volt coil and over load element with necessary material and connected to supply, etc complete. Starter with original sheet steel encloser.7.5 HP Pump
34Item No.8: - Providing tools for pumping machinary
35Item No.9:- Aluminium conductor 4 Core, XLPE / PVC insulated & armoured cableSupplying and erecting, XLPE / PVC insulated, annoured cable 1100 V grade with ISi mark Four core, solid/ stranded aluminium conductor with 6 mm thick 25 mm width M.S. spacer withG.I. Earth wire 6 sq mm, complete erected on wall / on pole with 25 X 3 mm M.S. clamps or in provided trench in an approved manner.
36Item No 10:- Providing and supplying ISI standard CI flanged / S& S specials excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store, unloading stacking etc. complete.
37Item No 11:- EARTHINGSupplying & errecting galvanised cast iron earth plate size 60 x 60 x .6 cm complete with all materials , testing as per specification No.EA-EP
38Item No 12:- Providing & fixing 100 mm dia. Pressure gauge.
39S.W. No. 04:- PURE WATER RISING MAIN OF HDPE 6 Kg 90 mm Item No.1:- Providing and supplying in standard lengths Polyethelene Pipes, confirming to IS 4984 / 14151 / 12786 / 13488 with nesessary jointing material like mechanical connector i. e. thread / insert joint / quick release coupler joint / compression fitting joint or flanged joint excluding coupler/specials, includingb transportation and freight charges, inspection charges, loading / unloading charges, conveyance to the departmental stores & stacking the same in closed shade duly protecting from sunrays & rains, excluding GST levied by GI & GOM in all respect etc. complete. 90 mm Dia. 6Kg
40Item No.2:- Providing ISI mark G.I. pipe of following class and dia.excluding GST levied by GOI and GOM in all respect including inspection charges, transportation to stores, etc. complete as per IS-1239/2004.80 mm Dia. Medium Class
41Item No 3:- Providing & supplying DI/GI specials ( 5 % of cost of pipe shall be considered percent of specials for estimate purpose.)
42Item No 4:- Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.80 mm dia.
43Item No 5:- Providing and Fixing ISI mark CI D/F reflux valves (non-return valves ) of following dia including railway freight, inspection charges, unloading from railway wagon, loading into truck, transportation upto departmental stores, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete.Reflux valves as per I.S.5312 Part I (1984) 80 mm dia.
44Item No 6:- Providing and supplying Air Valves as per IS- 14845-2000 and MJP’s standard specifications of approved make and quality of following diameters including railway freight, inspection charges, unloading from railway wagons, loading into truck, transportation upto departmental stores, unloding and stacking excluding GST levied by GOI & GOM in all respect etc. complete. 25 mm dia.
45Item No.7:-Excavation for foundation / Pipe Trenches in earth soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete.
46Item No.8:-Excavation for foundation / pipe trenches in hard murum with boulders, WBM roads including removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.
47Item No.9:-Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation, asphalt roadincluding removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.
48Item No.10 :- Excavation for foundation / pipe trenches in hard rock by controlled blasting, including trimming and levelling the bed by chiselling where necessary and removing the excavated material and stacking it in measurable heaps within a distance of 50 metres from the area and lifts as below, normal dewatering, excluding backfilling, etc. complete.
49Item No.11 :- Filling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.
50Item No.12:- Lowering, Laying and Jointing H. D. P. E./M D. P. E. pipes in proper position including all specials by compression fitting/electrofusion and butt fusion jointing procedure as per relevent IS Code complete with all materials for jointing procedure like Electrofusion machine, Electric heater/butt fusion welding machine with hydraulicjack, top loading clamp etc. and all labours as directed by engineer in charge as per IS-7634 Part II 90 mm Dia HDPE 6 Kg
51Item No.13:- Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, etc. complete either underground or in vertical position, as directed by Engineer-in-charge. 80 mm Dia
52Item No 14:- Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge100 mm Dia.
53Item No.15 :- Providing and laying in situ 1:2:4 (M-150) grade of C.C. of trap / granite/ quartzite/ gneiss metal for foundation and bedding including dewatering, form work, compacting and curing finishing etc complete with initial lift of 1.50m below /above ground level.
54Item No 16:- Providing and fixing in position air valve shaft including providingand fixing GI Medium class or 6mm thick M.S, PIPE shaft 2.70m long over branch flange of air valve tee providing PCCblock of M- 150concrete 150mm thick around the air valve tee including encasing of vertical shaft in PCC M-150 as shown in type design together with providing and making flanged ionts wherver required and fixing of air valve over the shaft excluding cost of air vavle and branch flanged air valve tee, etc. complete as per type desihn and as per directed by Engineer - in -charge for following diameters of pipe line25 mm Dia.
55Item No 17:- Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-charge 60 x 45 x 90 Cm
56Item No 18:- Hydraulic testing of H. D. P. E./ M. D. P. E. pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.110 mm Dia. 6 Kg
57Item No 19:- Hydraulic testing of G. I. pipe line to specified pressure including cost of all materials and labour and water for testing for the length upto 1km using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour operation charges etc. required for testing, The rates under this item shall also include cost of retesting if necessary and reinstating to original postion.80 mm Dia.
58Item No.20 :- Refilling the trenches with available excavated stuff with soft material first over pipeline and then hard murum material in 15cm layers with all leads and lifts including consolidation, surcharging etc. complete.
59S.W. No. 05:- RCC ESR cap. 15000 Lit. 12 m Staging Item No 1:- Designing (aesthetically) and constructing RCC elevated service reservoirs of following capacity with RCC staging consisting of columns, internal and external bracings spaced vertically not more than 4.5M. Centre to centre for ESR having capacity upto 500cum and not more than 6 m. c/c for ESRs having capacity above 500 cum including excavation in all types of strata, foundation concrete, cement plaster with water proofing compound to the inside face of the container including refilling disposing of the surplus stuff within a lead of 50 M. all labour and material charges including lowering, laying, erecting,, hoisting and jointing of pipe assembly of inlet, outlet, washout, overflow and bypass arrangements as per departmental desing, providing and fixing accessories such as M.S. ladder, C.I. manhole frame and covers water level indicatiors, lightening conductor, G.I. pipe railing around walk 15000 Lit. Cap.
60Item No.2:-Providing and supplying ISI standard welded DI double flanged pipes excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to stores unloading etc. complete as directed by Engineer-in-charge.,100 mm Dia. DIDF Pipe For Inlet
61100 mm Dia. DIDF Pipe For Outlet
62Item No.3:- Providing double flange sluice valve confirming for IS- 14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 150 mm dia. CIDF Sluice Valve
63Item No 4:- Providing and supplying ISI standard CI flanged / S& S specials excluding GST levied by GOI & GOM in all respect including railway freight, insurance, unloading from railway wagon, loading into truck transport to departmental store, unloading stacking etc. complete. Diameter 80 mm to 300 mm
64S.W. No. 06:- Distribution System Item No.1:- Providing and supplying in standard lengths ISI mark rigid unplasticised PVC pipes suitable for potable water with solvent cement joints including cost of couplers, as perIS specification no. 4985 / 1988 excluding GST levied by GOI and GOM in all respect, including transportation, freight charges, inspection charges, loading, unloading, conveyance to the departmental stores and stacking the same in closed shed duly protected from sun rays and rains including cost of jointing material i.e. solvent cement, etc. complete (selffit type to be jointed with cement solvent). 75 mm Dia 4 Kg/cm2
6590 mm Dia 4 Kg/cm2
66Item No.2:-Providing ISI mark G.I. pipe of following class and dia.excluding GST levied by GOI and GOM in all respect including inspection charges, transportation to stores, etc. completeas per IS-1239/2004.\ 80 mm Dia medium class
67Item No.3:- Providing double flange sluice valve confirming for IS-14846 including worn gear arrangements as per test pressure,stainless steel spindle, caps, including inspection charges, transportation upto departmental store, unloading, stacking excluding GST levied by GOI & GOM in all respect etc. complete. 80 mm dia. CIDF Sluice Valve
68Item No.4: -Providing and supplying PVC/C.I/G.I. Specials.
69Item No.5:- Excavation for foundation / Pipe Trenches in earth soil of all types, sand, gravel and soft murum including removing the excavated material upto a distance of 50mtrs. And lift as below stacking and spreading as directed, manual dewatering, preparing the bed for foundation and excluding back filling etc. complete. 0.0 to 1.50.
70Item No.6:- Excavation for foundation / pipe trenches in hard murum with boulders, WBM roads including removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.
71Item No.7:- Excavation for foundation / pipe trenches in soft rock and old cement and lime masonry foundation, asphalt roadincluding removing the excavated material upto a distance of 50 meters beyond the area and lifts as below, stacking and spreading as directed by Engineer-in-charge, normal dewatering, preparing the bed for foundation and excluding back filling etc. complete.
72Item No.8:- Excavation for foundation / pipe trenches in hard rock and concrete road by chiselling, wedging, line drilling, by machnial means or by any other means other than blasting including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the area and lifts as below, stacking as directed by Engineer-in-charge, normal dewatering, excluding backfilling, etc. complete.
73Item No.9:- Lowerig and laying and jointing with PVC pipes and specials of following class and diameter including cost of conveyance from stores to site of works including cost of all labour, material except cement solvent, rubber ring giving satisfactory hydraullic testing as per IS Code etc complete (with cement sovlentjoint / ring fit joint working pressure 4 Kg./Sqm.) 75 mm Dia 4 Kg/cm2
7490 mm Dia 4 Kg/cm2
75Item No.10:- Lowering, laying and jointing G. I. pipes and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test, etc. complete either underground or in vertical position, as directed by Engineer-in-charge. 80 mm Dia. Medium Class
76Item No 11 :-Hydraulic testing of PVC pipe line to specified pressure including cost of all materials and labour and water for testing for specified length including cutting, placing end cap making arrangement for filling safe water using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rate under this item shall also include cost of retesting, if necessary and reinstating to original position.75 mm Dia. 4 Kg/cm2
7790 mm Dia 4 Kg/cm2
78Item No 12 :- Hydraulic testing of G.I.pipeline to specified pressure including cost of all materials and labour and water for testing for the length upto 1km., using reciprocating type pumps which should be able to provide specified test pressure gauges and other necessary equipments, labour, operation charges, etc. required for testing. The rates under this item shall also include cost of retesting.80 mm Dia. medium class
79Item No.13:- Lowering, laying and jointing Valves and specials of following class and diameter including conveyance from stores to site of works, all labour, giving satisfactory hydraulic test etc complete either underground or in vertical position as directed by Engineer-in-charge . 80 mm dia. CIDF Sluice Valve
80Item No.14:- Providing & costructing B.B masonry valve chamber with 15 cm thick 1: 3 :6 proportion PCC bedding ,excluding excavation ,B.B masonry in C.M 1:5 proportion precast RCC frame and cover etc. complete as directed by Engineer-in-charge60 x 45 x 90 cm
81Item No.15:- Refilling the trenches with available excavated stuff with soft material first over pipelines and then hard material in 15cm layers with all leads and lifts including consolidation surcharging etc complete.
82Item No.16:- Providing and laying in situ 1:2:4(M-150) grade of C.C. of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including dewatering from work, compacting and curing, finishing etc. complete with initial lift of 1.50m below / above ground level.
83Item No.17:- Filling in plinth and floors murum bedding in trenches with approved murum from excavated materials from foundation 15cm to 20cm layers including watering and compaction, etc complete. (Bd-A-10/263)
84S.W. No. 7:- Trial RunItem NO 1 :- Commisioning running and maintaining the scheme to quantites, rated capacity, including manning necessary personnel such as operator, valveman, etc. as per requirements of the scheme and who should also administer chemical dose for a period .For Single Village

AI Tender Summary

OUR REF NO 34094962
AUTHORITY Government Departments
TENDER VALUE 26.24 Lakhs
LAST DATE 03-10-2022
Authority
Authority Name Rural Development Department
Work Description Retrofitting Of pipe water supply Scheme Basar Tal Sakri Dist Dhule
Basic Detail
Tender No DZP/RWS/JJM/65/2022
Bidding Type Tender
Location
City basar
State Maharashtra
Key Dates
Publish Date 24 Sep 2022
Submission Date 03 Oct 2022
Open Date 05 Oct 2022
Finance
Tender Value 26.24 Lakhs
Tender Fee 1000
EMD Ref. Documents
Exemption Not Available
Document List
b0d6d256-1bb9-41f1-8ffd-c618068c5902.html
B1.pdf
BOQ_1449813.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 24, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 03, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 05, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

b0d6d256-1bb9-41f1-8ffd-c618068c5902.html

pdf

B1.pdf

xls

BOQ_1449813.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders