}

Electro-Mechanical And Civil Works To Be Carried Out At Mazbugh ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifi, Baramulla-Jammu And Kashmir

Public Health Engineering Department-PHED has published Electro-Mechanical And Civil Works To Be Carried Out At Mazbugh ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifi. Submission Date for this Tender is 24-10-2022. Cutting Crimping and Punching Tools Tenders in Baramulla Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34092700
Corrigendum : Electro-Mechanical And Civil Works To Be Carried Out At Mazbugh ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifi
Open Tender
Indian
Jammu And Kashmir
Baramulla
24-10-2022

Tender Details

Electro-Mechanical And Civil Works To Be Carried Out At Mazbugh ( Stage 1St And Stage 2Nd ) Electro-Mechanical And Civil Works-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 1St A ( Source Jehlum ) Discharge Of The Pump = 11000 Gph Dynamic Head = 90 Mspeed = 1450 Rpmworking Voltage = 380 ± 15 V, 03 Phaserating = Corresponding To The Head And Discharge Not Less Than 25 Hp.Rest Of Specification / Details Are As Per Clause 6 Of Annexure C Of Sbd 3 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 150Class:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 4 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 150`Rest Of Specification As Per Clause 11 Of Annexure C Of Sbd 5 Fabrication , Providing And Fiting Of Y- Junction Havingminimum 1M Arm Length Of Each Arm To Be Fabricated Out Of G.I C Class Pipe With M.S. Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends.Dia: 150 Mmrest Of Specification As Per Clause 8 Of Annexure C Of Sbd 6 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Size: Dn150pn:1.6 / 16 Rest Of Specification / Details Areas Per Clause 12 Of Annexure C Of Sbd 7 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 150Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 8 Providing And Fitting Of 150 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 9 Providing And Fitting Of Flanged Washout Tee 150 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 10 Supply Installation , Testing And Commissioning Of Level Ii Ht Transfromercapacity: 100 Kvarest Of Specification / Details Areas Per Clause 26 Of Annexure C Of Sbd 11 9 M Long St-410 Sp33 Polerest Details As Per Clause 32 Of Annexure C Of Sbd 12 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5 Cum / Pole 13 G.I V Cross With Top Bracket Including Clamps Rest Details As Per Clause 32 Of Annexure C Of Sbd 14 11 Kva Polymeric Insulators12 Kv , 5Kn , Lighting Impulse 75 Kv Positive And 80 Kv Negative With Creepage Distance 320Mmrest Details As Per Clause 31 Of Annexure C Of Sbd 15 Galvanized Nuts And Bolts ( 1Kg / Pole ) Rest Details As Per Clause 33 Of Annexure C Of Sbd 16 Danger Plate With Clampsrest Details As Per Clause 34 Of Annexure C Of Sbd 17 Anti Climbing Device With Clampsrest Details As Per Clause 35 Of Annexure C Of Sbd 18 Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20 Mm 2.5 Mtr Long Through Gi Strip 19 Red Oxide Coating Rest Details As Per Clause 37 Of Annexure C Of Sbd 20 Alumunium Paint Coating Rest Details As Per Clause 38 Of Annexure C Of Sbd 21 Stone Pad ( 300Mm X300mm X75mm ) Rest Details As Per Clauseof Annexure C Of Sbd 22 Pg Clamps Fo 50 Sqmm Acsr Conductor 23 Acsr Conductor 50 Sqmmrest Details As Per Clause 39 Of Annexure C Of Sbd 24 Gi Channel / Angle / Flat Of Sizes Including Clamps 25 11 Kva Go , Ab Switch 3 Phase, 3 Pole, 200 A, Vertical Typerest Details As Per Clause 28 Of Annexure C Of Sbd 26 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45Kn, Lighting Impulse 75Kv Positive And 80 Kv Negative, Creepage Distance 320Mm 27 Gapless Surge Arrrestor 9Kv, 10 Ka , La With Polymer Housing, Stn Typerest Details As Per Clause 30 Of Annexure C Of Sbd 28 50 Sq Mm ( 2 Ckt ) 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 29 Earthing Of Substation- Rest Details As Per Clause 48 Of Annexure C Of Sbd 30 Lt Distribution Box For 100 Kva Dtr With 4 Pole Mccb For Incomer & SfuS For Outgoing Circuitsrest Details As Per Clause 42 Of Annexure C Of Sbd 31 Galvanised Stay Set With 50X8mm Stay Clam, Guy Insulators ( 2NoS ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts, 2 Nos; Turn-Buckles, 1.8M Long, 16Mm Dia Meter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Completerest Details As Per Clause 36 Of Annexure C Of Sbd 32 Wedge Connectors / Pg Clampsrest Details As Per Clause 36 Of Annexure C Of Sbd 33 Providing, Installation, Testing And Commissioning Of Outdoor Type Ht Trivectometer As Per Iee Rule. Job Includes Grouting Of Legs In Cement Concrete As Per Site Requirement. All Cabling, Earthing And Allied Accessories Required To Be Provided By The Firm. Moreover Firm Responsible For Completing All Sealing Of Pdddepartment And Testing On Load And Noload At Site 34 Sundry Items Like Alumunium Lugs , Jumprs, Binding Tape 35 35 Sq Mm Ab ( Ht ) Cable ( 3X35+1X70 Sqmm ) Xlpe ( 11 Kv , 3C+Earth ) Rest Details As Per Clause 41 Of Annexure C Of Sbd 36 Heat Shrinkable Outdoor Cable Termination Kitrest Details As Per Clause 73 Of Annexure C Of Sbd 37 Providing & Fitting Of35 Sq Mm Single Core Copper Conductor ( Flexible ) Pvc Insulated Heavy Duty Industrial Cables ( Unsheathed ) , 1100 Volts Conforming To Is: 694- For Connecting Motors From Panel , Stabilizers In Rubber Conduit . Job Includes Providing& Laying Of Flexible Conduit For Cu Cable With Lugs As Per Requirement Heat Shrinkable Outdoor Cable Termination Kitrest Details As Per Clause 73 Of Annexure C Of Sbd 38 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts; 70 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 68 Of Annexure C Of Sbd 39 Providing, Installation, Testing And Commissioning Of 75 Kva Voltage Stabilizer Rest Details & Specification As Per Clause 44 Of Annexure C Of Sbd 40 Fabrication Providing And Fitting Of 3 Phase Modular Control Panel. The Technical Details / Ratings Of Various Components Of Modular Control Panel Are Given Below B. Main Circuit Breaker = 250 Ac. Changeover Switch = 200 Ad. Motor Breakup Protectionmccb= 200 Ae. Fasdstarter - 2 Units With Rating Line Contactor _Ac3 90 A , Delta Contactor- Ac3 90 Astar Contractor- Ac3 70Atimer- Star Delta Electronicthermal Overload Relay- With Relay Range 20-50 Direct / Ct Operated Suitable-Rangeaux Coil Voltage Wide Band Fitted With Seperate Stabilization Unit Min 1Kw Aux Wiringf ) . Auxillary Mccb =63 Ampwith S.C. Breaking Capacity Of36kag ) . Motor Protection Relay Suitablei ) M-Power Module For Mobile Starter & Earth Fault Relay J ) Water Level Controller Rest Of Deatils / Technical Specification Are As Per Clause 43 Ofannexure C Of Sbd 41 Providing, Installation And Testing Ofheavy Duty Manual Type Triple Spur Gear Chainpulley Block Along With Monorail Geared Travelling Trolley Having Followingfeaturesmake = Reputed Make Capacity = 3 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mrest Details / Specification As Per Clause 24 Of Annexure C Of Sbd 42 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole Rest Of Deatils / Technical Specification Are As Per Clause 50 Ofannexure C Of Sbd 43 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole , Including Mcb Fiited In Box 10Arest Details / Specification As Per Clause 51 Of Annexure C Of Sbd 44 Providing And Installation Of Junction Box With Dp 32Amp Mcb To Serve As Amin Switch For Led Lighting Including Complete Wiring Min 20-30 M From Panel Board.Rest Details / Specification As Per Clause 52 Of Annexure C Of Sbd 45 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer , Including Wiringrest Details / Specification As Per Clause 53 Of Annexure C Of Sbd 46 Providing & Fitting Oflighting Points For ( Machine Room , Operators Room, ) As Per Site Requirement In 1.5 Mm² Multistranded Single Core 1100 Volts, Pvc Insulatedcopper Conductor Through Pvcconduit Pipe By Way, Switches, Socket Modules , Regulators , Indicators, 08 / 10 Watt Led Lamps Surface Light Make. .Included Is Cost On Account Of Modular Switch Boards With The Wooden Frames As Per Site Requirements 47 Providing Fitting Of Heating Points In 2.5Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit By Way Of P / F Of 15 Amp Switches, 6 Pin Socketon Modularfittingas Per Site Requirements. Heating Points Are To Be Connected From Main Control Panel. All Accessories Required Is To Be Provided By The Firm 48 Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. Make Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. 49 Providing, Fitting Of Distribution Board Of Reputed Make 4 Way S P N Single Door Powder Coated Sheet Steel Enclosure For Surface Mounting Fitted With Bus Bar, Din Channel, Neutral Link And Incoming Contact. The Above Db Is To Be Provided / Fitted With Double Pole 40 Amp Mcb For Main. 32 A For Heating Circuit & Rest 3 Of 16 / 6 Amps Each For Premises Luminary, Auxiliary Circuit Of Reputed Make. Further Job Includes Providing / Fitting 4 Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit As Service Line From Main Panel As Per Site Requirements. Connections Should Be Made In Such A Way Lighting Pointsis To Be Connected Via Automatic Transformer By Way Of P / F Switch Socket Arrangement With Allied Fixtures & And Heating Points To Main Panel. Job Includes Dismantling Of Existing Damaged Conduit , Wires, Conduit And Cleaning The Surface Properly 50 Earthing Of Panel Boad, Stabilizer, Motors, Heating Points, Lighting Points, D.G Setsrest Details As Per Clause 48 Of Annexure C Of Sbd 51 Design, Supply , Installation , Testing And Commissioning Of Automaatic Power Factor Correction Panel Suitable For 30 Hp Motor For Improvement Of Power Factor As Per Specifications Laid In Clause 45 Of Annexure C Of Sbd 52 Painting On Steel Structure / Pipe With Synthetic Enamel Paint Of Approved Brand And Maufacturer Of Required Colour To Give An Even Shade On New Work ( Two Or More Coats ) Including A Coat Of Approved Steel Primer But Excluding A Coat Of Mordant Solution. ( Ref 13.61 ) Schedule2021 53 Providing , Installation, Testing And Commissioning Of 415+-10 V ( Out Put ) , 3 Phase Dg Set Of Specification Of Approved Make As Per Latest Guide Linecapacity =82.5 Kvarest Details / Specifications Are As Per Clause 66 Of Annexure C Of Sbd 54 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts; 95 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 67 Of Annexure C Of Sbd 55 Fabrication, Providing, Fitting Of Base Framefor Pumping Units , Covering Of Holes , Fabrication Of Gantry, Ladder , Dg Set Covering, Ht / Lt Transformer Bed With Gantry Fabricated Out Of Ismc / Ismb / Isa / Bars / Ms Pipe / Ms Plain-Chequrred Sheets. Including Making Of Holes In Concrete, Including Metal Primer 1 Coat And Two Coats Of Approved Shade . The Works Is To Be Executed As Per Site Requirement And As Per Dimentions Of Pumping Unit And As Per Directions Of Site Engineer.Rest Of Specification / Details Are As Per Clause 21 Of Annexure C Of Sbd 56 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level 1:2:4 With Stone Aggregrate 20 Mm Nominal Size. For Dg Set Foundatioin / Concrete Beds For Rising-Main As Per Requirement 57 Centering And Shuttering Including Strutting, Propping Etc And Removal Of Form Work For Foundation, Footing , Base 58 Earth Work In Excavation By Manualmeans In Trenches For Foundations, Drains , Pipes , Cables Etc ( Not Exceeding 1.5 M In Width ) Andramming Of Bottoms Lift 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Exacavated Earth As Directed ( All Kinds Of Soil ) ( 2.81 Schedule ) 59 Providing And Laying Of Soling Stone 60 Cement Plaster In Find Sand In 1:3 Mix Finished With A Coat Of Neat Cement And Curing Complete 18 Mm Thick. ( S-11.8 ) 61 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter With 12V, 180Ah Tubular Inverter Batteryrest Details / Specification As Per Clause 54 Of Annexure C Of Sbd 62 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen . Rest Details / Specification As Per Clause 55Of Annexure C Of Sbd 63 Tool Kit For Maintenance: -The Tool Kit For Maintenance As Per Detailed Specification In Clause 56 Of Annexure C Of Sbd 64 Providing Of Good Quality Conveinence And Utility Items As Per Details In Clause57 Of Annexure C Of Sbd 65 Fabricationof6’ X 6’ Angle Iron Bedfor Operators. Rest Details / Specification As Per Clause 58 Of Annexure C Of Sbd 66 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos. Rest Details / Specification As Per Clause 59 Of Annexure C Of Sbd 67 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply.Rest Details / Specification As Per Clause 60 Of Annexure C Of Sbd 68 Providing Of Bamboo Ladder 18 Feet Long With 15 Feet Long Link Rods And Ht Gloves Pair ( 01 Each ) Rest Details / Specification As Per Clause 61 Of Annexure C Of Sbd 69 Providing Of 1 Kw Heat Convector For Operators For Winter Season.Rest Details / Specification As Per Clause 62 Of Annexure C Of Sbd 70 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metalrest Of Deatils / Technical Specification Are As Per Clause 63 Of Annexure C Of Sbd 71 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site. The Legs Are To Be Grouted In Cement Concrete.Rest Of Deatils / Technical Specification Are As Per Clause 64 Of Annexure C Of Sbd 72 Providing Corrugated G.S Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks , Bolts And Nuts For Dg Set And Overhead Gantryrest Of Deatils / Technical Specification Are As Per Clause 68 Of Annexure C Of Sbd 73 Stage 1St B ( Source Phoru Nallah ) 74 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 1St A ( Source Phoru Nallah ) Discharge Of The Pump = 11000 Gph Dynamic Head = 26 M Speed = 1450 Rpmworking Voltage = 380 ± 15 V, 03 Phaserating = Corresponding To The Head And Discharge Not Less Than 15 Hp.Rest Of Specification / Details Are As Per Clause 6 Of Annexure C Of Sbd 75 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 100Class:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 76 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 100`Mmrest Of Specification As Per Clause 11 Of Annexure C Of Sbd 77 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Size: Dn100pn:1.6 / 16 Rest Of Specification / Details Areas Per Clause 12 Of Annexure C Of Sbd 78 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 100Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 79 Providing And Fitting Of 100 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 80 Providing And Fitting Of Flanged Washout Tee 100 Mm Dia, Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 81 Providing And Fitting Of Flanged Washout Tee 150 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 82 Providing & Fitting Of25 Sq Mm Single Core Copper Conductor ( Flexible ) Pvc Insulated Heavy Duty Industrial Cables ( Unsheathed ) , 1100 Volts Conforming To Is: 694- For Connecting Motors From Panel , Stabilizers In Rubber Conduit . Job Includes Providing& Laying Of Flexible Conduit For Cu Cable With Lugs As Per Requirement Heat Shrinkable Outdoor Cable Termination Kitrest Details As Per Clause 73 Of Annexure C Of Sbd 83 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts; 70 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 68 Of Annexure C Of Sbd 84 Providing, Installation, Testing And Commissioning Of 75 Kva Voltage Stabilizer Rest Details & Specification As Per Clause 44 Of Annexure C Of Sbd 85 Fabrication Providing And Fitting Of 3 Phase Modular Control Panel. The Technical Details / Ratings Of Various Components Of Modular Control Panel Are Given Below B. Main Circuit Breaker = 250 Ac. Changeover Switch = 200 Ad. Motor Breakup Protectionmccb= 160 Ae. Fasdstarter - 2 Units With Rating Line Contactor _Ac3 90 A , Delta Contactor- Ac3 90 Astar Contractor- Ac3 70Atimer- Star Delta Electronicthermal Overload Relay- With Relay Range 20-50 Direct / Ct Operated Suitable-Rangeaux Coil Voltage Wide Band Fitted With Seperate Stabilization Unit Min 1Kw Aux Wiringf ) . Auxillary Mccb =63 Ampwith S.C. Breaking Capacity Of36kag ) . Motor Protection Relay Suitablei ) M-Power Module For Mobile Starter & Earth Fault Relay J ) Water Level Controller Rest Of Deatils / Technical Specification Are As Per Clause 43 Ofannexure C Of Sbd 86 Providing, Installation And Testing Ofheavy Duty Manual Type Triple Spur Gear Chainpulley Block Along With Monorail Geared Travelling Trolley Having Followingfeaturesmake = Reputed Make Capacity = 3 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mrest Details / Specification As Per Clause 24 Of Annexure C Of Sbd 87 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole Rest Of Deatils / Technical Specification Are As Per Clause 50 Ofannexure C Of Sbd 88 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole , Including Mcb Fiited In Box 10Arest Details / Specification As Per Clause 51 Of Annexure C Of Sbd 89 Providing And Installation Of Junction Box With Dp 32Amp Mcb To Serve As Amin Switch For Led Lighting Including Complete Wiring Min 20-30 M From Panel Board.Rest Details / Specification As Per Clause 52 Of Annexure C Of Sbd 90 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer , Including Wiringrest Details / Specification As Per Clause 53 Of Annexure C Of Sbd 91 Providing & Fitting Oflighting Points For ( Machine Room , Operators Room, ) As Per Site Requirement In 1.5 Mm² Multistranded Single Core 1100 Volts, Pvc Insulatedcopper Conductor Through Pvcconduit Pipe By Way, Switches, Socket Modules , Regulators , Indicators, 08 / 10 Watt Led Lamps Surface Light Make. .Included Is Cost On Account Of Modular Switch Boards With The Wooden Frames As Per Site Requirements 92 Providing Fitting Of Heating Points In 2.5Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit By Way Of P / F Of 15 Amp Switches, 6 Pin Socketon Modularfittingas Per Site Requirements. Heating Points Are To Be Connected From Main Control Panel. All Accessories Required Is To Be Provided By The Firm 93 Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. Make Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. 94 Providing, Fitting Of Distribution Board Of Reputed Make 4 Way S P N Single Door Powder Coated Sheet Steel Enclosure For Surface Mounting Fitted With Bus Bar, Din Channel, Neutral Link And Incoming Contact. The Above Db Is To Be Provided / Fitted With Double Pole 40 Amp Mcb For Main. 32 A For Heating Circuit & Rest 3 Of 16 / 6 Amps Each For Premises Luminary, Auxiliary Circuit Of Reputed Make. Further Job Includes Providing / Fitting 4 Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit As Service Line From Main Panel As Per Site Requirements. Connections Should Be Made In Such A Way Lighting Pointsis To Be Connected Via Automatic Transformer By Way Of P / F Switch Socket Arrangement With Allied Fixtures & And Heating Points To Main Panel. Job Includes Dismantling Of Existing Damaged Conduit , Wires, Conduit And Cleaning The Surface Properly 95 Earthing Of Panel Boad, Stabilizer, Motors, Heating Points, Lighting Points, D.G Setsrest Details As Per Clause 48 Of Annexure C Of Sbd 96 Fabrication, Providing, Fitting Of Base Framefor Pumping Units , Covering Of Holes , Fabrication Of Gantry, Ladder , Dg Set Covering, Ht / Lt Transformer Bed With Gantry Fabricated Out Of Ismc / Ismb / Isa / Bars / Ms Pipe / Ms Plain-Chequrred Sheets. Including Making Of Holes In Concrete, Including Metal Primer 1 Coat And Two Coats Of Approved Shade . The Works Is To Be Executed As Per Site Requirement And As Per Dimentions Of Pumping Unit And As Per Directions Of Site Engineer.Rest Of Specification / Details Are As Per Clause 21 Of Annexure C Of Sbd 97 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level 1:2:4 With Stone Aggregrate 20 Mm Nominal Size. For Dg Set Foundatioin / Concrete Beds For Rising-Main As Per Requirement 98 Centering And Shuttering Including Strutting, Propping Etc And Removal Of Form Work For Foundation, Footing , Base 99 Earth Work In Excavation By Manualmeans In Trenches For Foundations, Drains , Pipes , Cables Etc ( Not Exceeding 1.5 M In Width ) Andramming Of Bottoms Lift 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Exacavated Earth As Directed ( All Kinds Of Soil ) ( 2.81 Schedule ) 100 Providing And Laying Of Soling Stone 101 Cement Plaster In Find Sand In 1:3 Mix Finished With A Coat Of Neat Cement And Curing Complete 18 Mm Thick. ( S-11.8 ) 102 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter With 12V, 180Ah Tubular Inverter Batteryrest Details / Specification As Per Clause 54 Of Annexure C Of Sbd 103 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen . Rest Details / Specification As Per Clause 55Of Annexure C Of Sbd 104 Clear Water Stage 105 Providing, Fitting, Installation, Testing And Commissioning Of Hz Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 2Nddischarge Of The Pump = 10000 Gph Dynamic Head = 33 M , With Head Range 25-50Speed = 1450 Rpmworking Voltage = 380 ± 15 V, 03 Phaserating = Corresponding To The Head And Discharge Not Less Than 20 Hp.Rest Of Specification / Details Are As Per Clause 5 Of Annexure C Of Sbd 106 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 100Class:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 107 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 100`Rest Of Specification As Per Clause 11 Of Annexure C Of Sbd 108 Fabrication , Providing And Fiting Of Y- Junction Havingminimum 1M Arm Length Of Each Arm To Be Fabricated Out Of G.I C Class Pipe With M.S. Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends.Dia: 100 Mmrest Of Specification As Per Clause 8 Of Annexure C Of Sbd 109 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Size: Dn100pn:1.6 / 16 Rest Of Specification / Details Areas Per Clause 12 Of Annexure C Of Sbd 110 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 100Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 111 Providing And Fitting Of 100 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 112 Providing And Fitting Of Flanged Washout Tee 100 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 113 Providing And Fitting Of 100 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 114 Providing And Fitting Of Flanged Washout Tee 100 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 115 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 80Class:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 116 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 80`Rest Of Specification As Per Clause 11 Of Annexure C Of Sbd 117 Providing And Fitting Of 80 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 118 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 80Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 119 Supply Installation , Testing And Commissioning Of Level Ii Ht Transfromercapacity: 100 Kvarest Of Specification / Details Areas Per Clause 26 Of Annexure C Of Sbd 120 9 M Long St-410 Sp33 Polerest Details As Per Clause 32 Of Annexure C Of Sbd 121 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5 Cum / Pole 122 G.I V Cross With Top Bracket Including Clamps Rest Details As Per Clause 32 Of Annexure C Of Sbd 123 11 Kva Polymeric Insulators12 Kv , 5Kn , Lighting Impulse 75 Kv Positive And 80 Kv Negative With Creepage Distance 320Mmrest Details As Per Clause 31 Of Annexure C Of Sbd 124 Galvanized Nuts And Bolts ( 1Kg / Pole ) Rest Details As Per Clause 33 Of Annexure C Of Sbd 125 Danger Plate With Clampsrest Details As Per Clause 34 Of Annexure C Of Sbd 126 Anti Climbing Device With Clampsrest Details As Per Clause 35 Of Annexure C Of Sbd 127 Earthing Complete By Gi Pipe 40 Mm Or Gi Rod 20 Mm 2.5 Mtr Long Through Gi Strip 128 Red Oxide Coating Rest Details As Per Clause 37 Of Annexure C Of Sbd 129 Alumunium Paint Coating Rest Details As Per Clause 38 Of Annexure C Of Sbd 130 Stone Pad ( 300Mm X300mm X75mm ) Rest Details As Per Clauseof Annexure C Of Sbd 131 Pg Clamps Fo 50 Sqmm Acsr Conductor 132 Acsr Conductor 50 Sqmmrest Details As Per Clause 39 Of Annexure C Of Sbd 133 Gi Channel / Angle / Flat Of Sizes Including Clamps 134 11 Kva Go , Ab Switch 3 Phase, 3 Pole, 200 A, Vertical Typerest Details As Per Clause 28 Of Annexure C Of Sbd 135 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45Kn, Lighting Impulse 75Kv Positive And 80 Kv Negative, Creepage Distance 320Mm 136 Gapless Surge Arrrestor 9Kv, 10 Ka , La With Polymer Housing, Stn Typerest Details As Per Clause 30 Of Annexure C Of Sbd 137 50 Sq Mm ( 2 Ckt ) 1.1 Kv Grade, Pvc Insulated Stranded Conductor Frls Type 138 Earthing Of Substation- Rest Details As Per Clause 48 Of Annexure C Of Sbd 139 Lt Distribution Box For 100 Kva Dtr With 4 Pole Mccb For Incomer & SfuS For Outgoing Circuitsrest Details As Per Clause 42 Of Annexure C Of Sbd 140 Galvanised Stay Set With 50X8mm Stay Clam, Guy Insulators ( 2NoS ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts, 2 Nos; Turn-Buckles, 1.8M Long, 16Mm Dia Meter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Completerest Details As Per Clause 36 Of Annexure C Of Sbd 141 Wedge Connectors / Pg Clampsrest Details As Per Clause 36 Of Annexure C Of Sbd 142 Providing, Installation, Testing And Commissioning Of Outdoor Type Ht Trivectometer As Per Iee Rule. Job Includes Grouting Of Legs In Cement Concrete As Per Site Requirement. All Cabling, Earthing And Allied Accessories Required To Be Provided By The Firm. Moreover Firm Responsible For Completing All Sealing Of Pdddepartment And Testing On Load And Noload At Site 143 Sundry Items Like Alumunium Lugs , Jumprs, Binding Tape 144 35 Sq Mm Ab ( Ht ) Cable ( 3X35+1X70 Sqmm ) Xlpe ( 11 Kv , 3C+Earth ) Rest Details As Per Clause 41 Of Annexure C Of Sbd 145 Heat Shrinkable Outdoor Cable Termination Kitrest Details As Per Clause 73 Of Annexure C Of Sbd 146 Providing & Fitting Of25 Sq Mm Single Core Copper Conductor ( Flexible ) Pvc Insulated Heavy Duty Industrial Cables ( Unsheathed ) , 1100 Volts Conforming To Is: 694- For Connecting Motors From Panel , Stabilizers In Rubber Conduit . Job Includes Providing& Laying Of Flexible Conduit For Cu Cable With Lugs As Per Requirement Heat Shrinkable Outdoor Cable Termination Kitrest Details As Per Clause 73 Of Annexure C Of Sbd 147 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts; 70 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 68 Of Annexure C Of Sbd 148 Providing, Installation, Testing And Commissioning Of 75 Kva Voltage Stabilizer Rest Details & Specification As Per Clause 44 Of Annexure C Of Sbd 149 Fabrication Providing And Fitting Of 3 Phase Modular Control Panel. The Technical Details / Ratings Of Various Components Of Modular Control Panel Are Given Below B. Main Circuit Breaker = 250 Ac. Changeover Switch = 200 Ad. Motor Breakup Protectionmccb= 160 Ae. Fasdstarter - 2 Units With Rating Line Contactor _Ac3 90 A , Delta Contactor- Ac3 90 Astar Contractor- Ac3 70Atimer- Star Delta Electronicthermal Overload Relay- With Relay Range 20-50 Direct / Ct Operated Suitable-Rangeaux Coil Voltage Wide Band Fitted With Seperate Stabilization Unit Min 1Kw Aux Wiringf ) . Auxillary Mccb =63 Ampwith S.C. Breaking Capacity Of36kag ) . Motor Protection Relay Suitablei ) M-Power Module For Mobile Starter & Earth Fault Relay J ) Water Level Controller Rest Of Deatils / Technical Specification Are As Per Clause 43 Ofannexure C Of Sbd 150 Providing, Installation And Testing Ofheavy Duty Manual Type Triple Spur Gear Chainpulley Block Along With Monorail Geared Travelling Trolley Having Followingfeaturesmake = Reputed Make Capacity = 3 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mrest Details / Specification As Per Clause 24 Of Annexure C Of Sbd 151 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole Rest Of Deatils / Technical Specification Are As Per Clause 50 Ofannexure C Of Sbd 152 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole , Including Mcb Fiited In Box 10Arest Details / Specification As Per Clause 51 Of Annexure C Of Sbd 153 Providing And Installation Of Junction Box With Dp 32Amp Mcb To Serve As Amin Switch For Led Lighting Including Complete Wiring Min 20-30 M From Panel Board.Rest Details / Specification As Per Clause 52 Of Annexure C Of Sbd 154 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer , Including Wiringrest Details / Specification As Per Clause 53 Of Annexure C Of Sbd 155 Providing & Fitting Oflighting Points For ( Machine Room , Operators Room, ) As Per Site Requirement In 1.5 Mm² Multistranded Single Core 1100 Volts, Pvc Insulatedcopper Conductor Through Pvcconduit Pipe By Way, Switches, Socket Modules , Regulators , Indicators, 08 / 10 Watt Led Lamps Surface Light Make. .Included Is Cost On Account Of Modular Switch Boards With The Wooden Frames As Per Site Requirements 156 Providing Fitting Of Heating Points In 2.5Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit By Way Of P / F Of 15 Amp Switches, 6 Pin Socketon Modularfittingas Per Site Requirements. Heating Points Are To Be Connected From Main Control Panel. All Accessories Required Is To Be Provided By The Firm 157 Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. Make Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. 158 Providing, Fitting Of Distribution Board Of Reputed Make 4 Way S P N Single Door Powder Coated Sheet Steel Enclosure For Surface Mounting Fitted With Bus Bar, Din Channel, Neutral Link And Incoming Contact. The Above Db Is To Be Provided / Fitted With Double Pole 40 Amp Mcb For Main. 32 A For Heating Circuit & Rest 3 Of 16 / 6 Amps Each For Premises Luminary, Auxiliary Circuit Of Reputed Make. Further Job Includes Providing / Fitting 4 Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit As Service Line From Main Panel As Per Site Requirements. Connections Should Be Made In Such A Way Lighting Pointsis To Be Connected Via Automatic Transformer By Way Of P / F Switch Socket Arrangement With Allied Fixtures & And Heating Points To Main Panel. Job Includes Dismantling Of Existing Damaged Conduit , Wires, Conduit And Cleaning The Surface Properly 159 Earthing Of Panel Boad, Stabilizer, Motors, Heating Points, Lighting Points, D.G Setsrest Details As Per Clause 48 Of Annexure C Of Sbd 160 Painting On Steel Structure / Pipe With Synthetic Enamel Paint Of Approved Brand And Maufacturer Of Required Colour To Give An Even Shade On New Work ( Two Or More Coats ) Including A Coat Of Approved Steel Primer But Excluding A Coat Of Mordant Solution. ( Ref 13.61 ) Schedule2021 161 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts; 70 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 67 Of Annexure C Of Sbd 162 Fabrication, Providing, Fitting Of Base Framefor Pumping Units , Covering Of Holes , Fabrication Of Gantry, Ladder , Dg Set Covering, Ht / Lt Transformer Bed With Gantry Fabricated Out Of Ismc / Ismb / Isa / Bars / Ms Pipe / Ms Plain-Chequrred Sheets. Including Making Of Holes In Concrete, Including Metal Primer 1 Coat And Two Coats Of Approved Shade . The Works Is To Be Executed As Per Site Requirement And As Per Dimentions Of Pumping Unit And As Per Directions Of Site Engineer.Rest Of Specification / Details Are As Per Clause 21 Of Annexure C Of Sbd 163 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level 1:2:4 With Stone Aggregrate 20 Mm Nominal Size. For Dg Set Foundatioin / Concrete Beds For Rising-Main As Per Requirement 164 Centering And Shuttering Including Strutting, Propping Etc And Removal Of Form Work For Foundation, Footing , Base 165 Earth Work In Excavation By Manualmeans In Trenches For Foundations, Drains , Pipes , Cables Etc ( Not Exceeding 1.5 M In Width ) Andramming Of Bottoms Lift 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Exacavated Earth As Directed ( All Kinds Of Soil ) ( 2.81 Schedule ) 166 Providing And Laying Of Soling Stone 167 Cement Plaster In Find Sand In 1:3 Mix Finished With A Coat Of Neat Cement And Curing Complete 18 Mm Thick. ( S-11.8 ) 168 Supply, Installation, Testing & Commissioning Of 1000Va Full Sine Wave Power Inverter With 12V, 180Ah Tubular Inverter Batteryrest Details / Specification As Per Clause 54 Of Annexure C Of Sbd 169 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen . Rest Details / Specification As Per Clause 55Of Annexure C Of Sbd 170 Tool Kit For Maintenance: -The Tool Kit For Maintenance As Per Detailed Specification In Clause 56 Of Annexure C Of Sbd 171 Providing Of Good Quality Conveinence And Utility Items As Per Details In Clause57 Of Annexure C Of Sbd 172 Fabricationof6’ X 6’ Angle Iron Bedfor Operators. Rest Details / Specification As Per Clause 58 Of Annexure C Of Sbd 173 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos. Rest Details / Specification As Per Clause 59 Of Annexure C Of Sbd 174 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply.Rest Details / Specification As Per Clause 60 Of Annexure C Of Sbd 175 Providing Of Bamboo Ladder 18 Feet Long With 15 Feet Long Link Rods And Ht Gloves Pair ( 01 Each ) Rest Details / Specification As Per Clause 61 Of Annexure C Of Sbd 176 Providing Of 1 Kw Heat Convector For Operators For Winter Season.Rest Details / Specification As Per Clause 62 Of Annexure C Of Sbd 177 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metalrest Of Deatils / Technical Specification Are As Per Clause 63 Of Annexure C Of Sbd 178 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site. The Legs Are To Be Grouted In Cement Concrete.Rest Of Deatils / Technical Specification Are As Per Clause 64 Of Annexure C Of Sbd 179 Providing Corrugated G.S Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks , Bolts And Nuts For Dg Set And Overhead Gantryrest Of Deatils / Technical Specification Are As Per Clause 68 Of Annexure C Of Sbd 180 Construction Of Sinking Well Cum Pump House ( Civil Works ) 181 Earth Work In Excavation By Mechanical Means Over Areas ( Exceeding 30Cm And Up [ To 1.5Mtr In Depth, 1.5Mtr In Width As Well As 10 Sqm On Plan ) Including Disposal Of Excavated Earth Upto 50M From Cutting Edge Disposal Earth To Be Levelled And Neatly Dressed .All Kinds Of Soil 182 Providing And Laying Of Dry Stone Soling In Horizontal On Level. 183 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering.1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Agg. 40 Mm Nominal Size Crushed 184 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 185 Reinforced Cement Concrete Work In Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts Andstruts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement. 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 186 Reinforced Cement Concrete Work In Beams, Suspended Floors, Roofs Having Slope Upto 15°, Landings, Balconies, Shelves, Chajjas, Lintels, Bands, Plain Window Sills, Staircases And Spiral Stair Cases Upto Five Level Including Curing But Excluding The Cost Of Centring, Shuttering, Finishing And Reinforcement With1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 187 Centering And Shuttering Including Strutting, Propping Etc, And Removal Of Form Work For Foundations, Footings, Bases For Columns 188 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Walls ( Any Thickness ) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs And Steps Etc. 189 Centring And Shuttering Including Strutting, Propping Etc, And Removal Of Form Work For Suspended Floors, Roofs, Landings, Balconies And Access Platforms. 190 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel , Beams & Cantilevers Etc 191 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Edges Of Slabs 192 Extra For Shuttering In Circular Workfor Foundations, Footings, Bases For Columns 193 Extra For Shuttering In Circular Workfor Walls 194 Extra For Shuttering In Circular Work For Lintels, Beams & Cantilevers 195 Extra For Shuttering In Circular Work For Suspended Floors 196 Finishing Walls With Water Proofing Cement Paint Of Required Shade On New Work ( Two Or More Coats Applied @ 3.84 Kg / 10Sqm ) 197 Providing And Fixing Hand Rail Of Approved Size By Welding Etc To Steel Ladder Railing, Balcony Railing And Stair Case Railing And Similar Work Including Applying A Priming Coat Of Approved Steel Primer. M.S Tube ( Medium ) 40Mmm Nominal Bore 198 Providing Corrugated G.S Sheet Roofing Including Vertical / Curved Surface Fixed With Polymer Coated J Or L Hooks, Bolts And Nuts 8Mm Diameter With Bitumen And G.I Limpet Washers Or With G.I Limpet Washers Filled With White Lead And Including A Coat Of Approved Steel Primer And Two Coats Of Approved Paint On Overlapping Of Sheets Complete ( Upto Any Pitch In Horizontal / Vertical Or Curved Surface ) Excluding The Cost Of Purlins, Rafters And Trusses And Including Cutting To Size And Shape Wherever Required. 0.50Mm Thick With Zinc Coating Not Less Than 275Gm / M2 199 Providing Ridges Or Hips Of Width 60Cm Over All Width Plain G.S Sheets With Polymer Coated J Or L Hooks, Bolts And Nuts 80Mm Dia G.I Limpet And Bitumen Washers Complete Job 200 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work Over An Under Coat Ofsuitable Shade With Ordinary Paint Of Approved Brand And Manufacture. 201 Providing And Fixing 12Mm Thick Plyboard For Covering The Ceiling Area Incl C / O Frames, Supports , Battens Incl All Sorts Of Screws Etc Complete Job 202 Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete ( T.M.T Bars ) 203 Brick Work In Fps Bricksof Class Designation 75 In Foundation And Plinth In Cement Mortor 1:4 Mix 204 Extra For Brick Work With Common Burnt Clay Bricks / Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level 205 Providing And Fixing Wire Gauze Shutters Using Galvanized M.S. Wire Gauze Of Average Width For Aperture 1.4 Mm In Both Directions With Wire Of Dia. 0.63 Mm For Doors, Windows And Clerestory Windows With Isi Marked M.S. Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws As Per Direction Of Engineer-In-Charge. First Class Kail Wood 206 Providing And Fixing At Site Eaves Boarding Of 200Mmwide Colouredncluding Cost Of Holders, Angle Supports Complete Job 207 Providing And Fixing Of 2Mm Ms Sheet Boardingincl Supports Etc Complete Job 208 15Mm Thick Cement Sand Plaster Finished With A Floating Coat Neat Cement Of Mix 1:4 ( 1 Cement : 4 Fine Sand ) 209 Structural Steel Work In Built Up Sections, Trusses And Framed Work, Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Steel Primer All Complete. Welded 210 Supply , Fabrication And Fixing In Position Ms Edge Cutter With Proper Anchorage Incl All Welding And As Per Directions Of Engineer Incharge 211 Sinking Of Well Through All Types Of Sink Complete As Per Drawings And All Technical Specification Having Inner Dia Of 5.50M By Way Of Making Of Platform Overhead Wall, With Loading, Unloading Of Sand Filled Ec Bags For Required Number Of Castings And Engagement Of Skilled Labour With Sinking Depth As Per Site Conditions And Removal Of Platform As Per Directions Of Site Engineer Incharge 212 Pumping Out Water Caused By Springs, Tidal Or River Seepage, Broken Water Mains Or Drains And The Like 213 Providing And Filling Of E.C Bags With Sand / Earth Including Cost Of E.C Bags, Eath, Sand All Carriages Costs Etc And Including Laying In Position To Acts As Copper Dam / Spur / Diversion, As Per Site Requriments And Directions Of Site Engineer. 214 Providing And Fixing Tie Bolt, Spring Coil And Plastic Cone In Wall Shuttering Complete As Per The Direction Of Engineer-In-Charge. 20 Mm Dia And 350 Mm Length 215 Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S Laths Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete Including The Cost Of Providing And Fixing Necessary 27.50Cm Long Wire Springs Manufacture From High Tensile Steel Wire Of Adequate Strength Confirming To Is 4454 Part 1 And M.S Top Cover Of Required Thickness For Rolling Shutters. 80X1.25Mm M.S Laths With 1.25Mm Thick Top Cover 216 Providing And Fixing Ball Bearing For Rolling Shutters 217 Providing And Fixing Glazed Shutters For Doors, Windows And Clerestory Windows Using 10Kg / Sqm ( 4Mm Thick ) Float Glass Panes Including Isi Marked M.S Pressed Butt Hinges Bright Finished Of Required Size With Necessary Screws. Second Class Kail Wood 218 Providing And Fixing Of 5Mm Thick Glass Sheets In Windows Incld. Cost Of All Complete Job As Directed By Site Engineer 219 Providing And Fixing Aluminium Handles Isi Marked Anodized ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour And Shade With Necessary Screws Etc Complete 100 Mm 220 Providing And Fixing Aluminium Tower Bolts Isi Marked Anodized ( Anodic Coating Not Less Than Grade Ac 10 As Per Is : 1868 ) Transparent Or Dyed To Required Colour Or Shade With Necessary Screws Etc Complete 100 X 10Mm 221 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Depositedlayer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 222 Carriage Of Material By Mechanical Transport 223 Cement & Steel Avg Lead 5 Km 224 Sandfor Average Lead Of 20Km 225 Bajree For Average Lead Of 20 Km 226 Stone Soling For 12 Km 227 Bricks For Average 80 Km 228 Construction Clear Water Sump Cum Pump House 229 Earth Work In Excavation By Mannual Means Over Areas ( Exceeding 30Cm And Upto 1.5M In Depth And Width As Well As 10 Sqm In Plan ) Including Disposal Of Excavated Earth Upto 1M Cutting Edge, Disposed Earth To Be Levelled And Neatly Dressed In All Kinds Of Soil. 230 Extra For Earthwork In Excavation Beyond 1.5M 231 Providing And Laying Of Dry Stone Soling In Horizontal On Level. 232 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering.1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Agg. 40 Mm Nominal Size Crushed 233 Providing And Laying In Position Specified Grade Of Reinforced Cement Concrete Including Curing But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement. All Works Upto Plinth Level 1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 234 Reinforced Cement Concrete Work In Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts Andstruts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement.1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 235 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.All Works Above Plinth Level . 236 Centering And Shuttering Including Strutting, Propping Etc, And Removal Of Form Work For Foundations, Footings, Bases For Columns 237 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Walls ( Any Thickness ) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs And Steps Etc. 238 Centring And Shuttering Including Strutting, Propping Etc, And Removal Of Form Work For Suspended Floors, Roofs, Landings, Balconies And Access Platforms. 239 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel , Beams & Cantilevers Etc 240 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Columns, Pillars, Piers, Abutments, Posts And Struts. 241 Extra For Shuttering In Circular Workfor Foundations, Footings, Bases For Columns 242 Extra For Shuttering In Circular Workfor Walls 243 Extra For Shuttering In Circular Work For Lintels, Beams & Cantilevers 244 Extra For Shuttering In Circular Work For Suspended Floors 245 Finishing Walls With Water Proofing Cement Paint Of Required Shade On New Work ( Two Or More Coats Applied @ 3.84 Kg / 10Sqm ) 246 Applying Priming Coat:With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work ( Hard And Soft Wood ) 247 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade. Two Or More Coats On New Work Over An Under Coat Of Suitable Shade With Ordinary Paint Of Approved Brand And Manufacture. 248 Reinforcement For R.C.C Work Including Straightening, Cutting, Bending, Placing In Position And Binding All Complete ( T.M.T Bars ) 249 Providing And Mixing Water Proofing Material In Cement Concrete Work In Doses By Weight Of Cement As Per Manufacturer’S Specification. ( 1 Kg Of Water Proofing Material In 50 Kg Of Cement ) 250 Brick Work In Fps Bricksof Class Designation 75 In Foundation And Plinth In Cement Mortor 1:4 Mix 251 Extra For Brick Work With Common Burnt Clay Bricks / Cement Concrete Bricks In Superstructure Above Plinth Level Upto Floor Five Level 252 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia And Length ( Hold Fast Lugs Or With Dash Fasteners Shall Be Paid For Separately ) 2Nd Class Kail Wood 253 Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) . Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40Mm Thick. For Door 254 Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) . Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40Mm Thick.For Float Glass Panes 4Mm Thick For Exterior Window Shutters 255 C ) Fly Proof Stainless Steel Grade 304 Wire Gauge With 0.5 Mm Dia Wire And 1.4 Mm Wide Aperture With Matching Wood Beading 256 12Mm Thick Cement Sand Plaster Finished With A Floating Coat Neat Cement Of Mix 1:3 257 Extra For Plastering On Circular Work One Coat. 258 Applying Priming Coat With Ready Mixed Red Oxide Zinc Chromate Primer Of Approved Brandand Manufacture On Steel Galvanised Iron / Steel Work 259 Supplying And Fixing Rolling Shutters Of Approved Make, Made Of Required Size M.S Laths Interlocked Together Through Their Entire Length And Jointed Together At The End By End Locks Mounted On Specially Designed Pipe Shaft With Brackets, Side Guides And Arrangements For Inside And Outside Locking With Push And Pull Operation Complete Including The Cost Of Providing And Fixing Necessary 27.50Cm Long Wire Springs Manufacture From High Tensile Steel Wire Of Adequate Strength Confirming To Is 4454 Part 1 And M.S Top Cover Of Required Thickness For Rolling Shutters. 80X1.25Mm M.S Laths With 1.25Mm Thick Top Cover 260 Providing And Fixing Ball Bearing For Rolling Shutters 261 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M. 262 Carriage Of Material By Mechanical Transport 263 Cement & Steel Avg Lead 5 Km 264 Sand & 20Mm Agg.For Average Lead Of 12Km 265 Bajree For Average Lead Of 20 Km 266 Stone Soling For 20 Km 267 Bricks For Average 80 Km

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Oct-2022 Extension of bid Date 24-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 342260.0 /-
Tender Value
INR 1.71 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail