Electro-Mechanical And Civil Works To Be Carried Out At Baba Shakrudin Electro-Mechanical And Civil Works=-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 1St Disc, Baramulla-Jammu And Kashmir

Public Health Engineering Department-PHED has published Electro-Mechanical And Civil Works To Be Carried Out At Baba Shakrudin Electro-Mechanical And Civil Works=-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 1St Disc. Submission Date for this Tender is 24-10-2022. Cutting Crimping and Punching Tools Tenders in Baramulla Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34092694
Corrigendum : Electro-Mechanical And Civil Works To Be Carried Out At Baba Shakrudin Electro-Mechanical And Civil Works=-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 1St Disc
Open Tender
Indian
Jammu And Kashmir
Baramulla
24-10-2022

Tender Details

Electro-Mechanical And Civil Works To Be Carried Out At Baba Shakrudin Electro-Mechanical And Civil Works=-2 Providing, Fitting, Installation, Testing And Commissioning Of Vt Pumping Unit Of Approved Make Withfollowing Specifications: At Stage 1St Discharge Of The Pump = 5000 Gph Dynamic Head = 70 M Speed = 1450 Rpmworking Voltage = 380 ± 15 V, 03 Phaserating = Corresponding To The Head And Discharge Not Less Than 15Hp.Rest Of Specification / Details Are As Per Clause 6 Of Annexure C Of Sbd 3 Providing / Supplying And Fitting Ofg.I Flanged Rising Main At Site. The Pipe Shall Be Hot Dip Galvanized, Class-C Confirming To Is 1239. The Job Includes Providing And Fitting Of M.S Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) For Y Junction And Washoutsize: 80 Mm Diaclass:C ( Heavy ) Rest Of Specification As Per Clause 8 Of Annexure C Of Sbd 4 Cutting Of Hot Dip Galvanized Gi , C-Class Pipe Acoss The Section By Dint Of Pipe Cutter / Gas Cutter. The Job Includes Providing And Welding Of M.S. Flanges To The Two Ends Of Pipe. The Thickness Of Flange Shall Conform To Is 6392 Part 1St Table-17Dia: 80 Mmrest Of Specification As Per Clause 11 Of Annexure C Of Sbd 5 Fabrication , Providing And Fiting Of Y- Junction Havingminimum 1M Arm Length Of Each Arm To Be Fabricated Out Of G.I C Class Pipe With M.S. Flanges Conforming To Bis 6392 / 1997 Table 17 ( Rating Pn16 ) Fastened With Weld Joints On Three Ends.Dia: 80 Mmrest Of Specification As Per Clause 8 Of Annexure C Of Sbd 6 Providing And Fitting Of, Ductile Iron Double Flanged, Non-Rising Spindle Soft Seatedglandless Gate / Sluice Valves As Per Is14846 For Regulating The Water Supply Outside The Pumping Units .Size: Dn80pn:1.6 / 16 Rest Of Specification / Details Areas Per Clause 12 Of Annexure C Of Sbd 7 Providing And Fitting Ofductile Iron Double Flanged, Slanted Seatswing Check Valve ( Nrv ) As Per Is 5312. Size: 80Mmpn: 1.6 / 16Rest Of Specification / Details Areas Per Clause 13 Of Annexure C Of Sbd 8 Providing And Fitting Of 80 Mm Dia Flanged Flanged Bends / Elbolw To Delivery Mainfold And Washout, Including Nuts And Bolts And Rubber Gaskets As Per Requirement.Rest Of Specification / Details Areas Per Clause 15 Of Annexure C Of Sbd 9 Providing And Fitting Of Flanged Washout Tee 80 Mm , Including Nuts, Bolts And Gasket As Per Site Requirement.Rest Of Specification / Details Areas Per Clause 09 Of Annexure C Of Sbd 10 Supply Installation , Testing And Commissioning Of Level Ii Ht Transfromercapacity: 63 Kvarest Of Specification / Details Areas Per Clause 26 Of Annexure C Of Sbd 11 9 M Long St-410 Sp33 Polerest Details As Per Clause 32 Of Annexure C Of Sbd 12 13 M Long St-410 Sp33 Polerest Details As Per Clause 32 Of Annexure C Of Sbd 13 Cement Bottoming 1:2:4 Mix As Per Rec Standards 0.5 Cum / Pole 14 G.I V Cross With Top Bracket Including Clamps Rest Details As Per Clause 32 Of Annexure C Of Sbd 15 11 Kva Polymeric Insulators12 Kv , 5Kn , Lighting Impulse 75 Kv Positive And 80 Kv Negative With Creepage Distance 320Mmrest Details As Per Clause 31 Of Annexure C Of Sbd 16 Galvanized Nuts And Bolts ( 1Kg / Pole ) Rest Details As Per Clause 33 Of Annexure C Of Sbd 17 Danger Plate With Clampsrest Details As Per Clause 34 Of Annexure C Of Sbd 18 Anti Climbing Device With Clampsrest Details As Per Clause 35 Of Annexure C Of Sbd 19 Red Oxide Coating Rest Details As Per Clause 37 Of Annexure C Of Sbd 20 Alumunium Paint Coating Rest Details As Per Clause 38 Of Annexure C Of Sbd 21 Stone Pad ( 300Mm X300mm X75mm ) Rest Details As Per Clauseof Annexure C Of Sbd 22 Pg Clamps Fo 50 Sqmm Acsr Conductor 23 Acsr Conductor 50 Sqmmrest Details As Per Clause 39 Of Annexure C Of Sbd 24 Gi Channel / Angle / Flat Of Sizes Including Clamps 25 11 Kva Go , Ab Switch 3 Phase, 3 Pole, 200 A, Vertical Typerest Details As Per Clause 28 Of Annexure C Of Sbd 26 11 Kv Polymeric Composite Disc Insulator 12 Kv, Min Failing Load 45Kn, Lighting Impulse 75Kv Positive And 80 Kv Negative, Creepage Distance 320Mm 27 Gapless Surge Arrrestor 9Kv, 10 Ka , La With Polymer Housing, Stn Typerest Details As Per Clause 30 Of Annexure C Of Sbd 28 Earthing Of Substation- Rest Details As Per Clause 48 Of Annexure C Of Sbd 29 Galvanised Stay Set With 50X8mm Stay Clam, Guy Insulators ( 2NoS ) , Anchor Plate ( 200X200x6mm ) , Nuts And Bolts, 2 Nos; Turn-Buckles, 1.8M Long, 16Mm Dia Meter Solid Gs Stay Rod & 7 / 3.15 Mm Dia Gi Stranded Wire Completerest Details As Per Clause 36 Of Annexure C Of Sbd 30 Sundry Items Like Alumunium Lugs , Jumprs, Binding Tape 31 Providing & Fitting Of35 Sq Mm Single Core Copper Conductor ( Flexible ) Pvc Insulated Heavy Duty Industrial Cables ( Unsheathed ) , 1100 Volts Conforming To Is: 694- For Connecting Motors From Panel , Stabilizers In Rubber Conduit . Job Includes Providing& Laying Of Flexible Conduit For Cu Cable With Lugs As Per Requirement Heat Shrinkable Outdoor Cable Termination Kitrest Details As Per Clause 73 Of Annexure C Of Sbd 32 Providing, Installation , Testing Of Power Service Cablefor Workingvoltage Up To And Including 1100 Volts;95 Sq Mm Armored Aluminum 3.5 Core Cable As Service Line From Output Terminals Of Ht / Lt Transformerto Cubical Panel. Cost Includes Laying Of Cable In Trenches In Pvc Conduit Where Ever Itis To Be Laid Underground As Per Site Requirement Included Is Termination Of Ends With Suitable Aluminum Tube Terminals Dully Crimpled & Taped. Rest Specifications As Per Clause 68 Of Annexure C Of Sbd 33 Providing, Installation, Testing And Commissioning Of 50 Kva Voltage Stabilizer Rest Details & Specification As Per Clause 44 Of Annexure C Of Sbd 34 Fabrication Providing And Fitting Of 3 Phase Modular Control Panel. The Technical Details / Ratings Of Various Components Of Modular Control Panel Are Given Below B. Main Circuit Breaker = 200 Ac. Changeover Switch = 200 Ad. Motor Breakup Protectionmccb= 160 Ae. Fasdstarter - 2 Units With Rating Line Contactor _Ac3 70 A , Delta Contactor- Ac3 70 Astar Contractor- Ac3 50 Atimer- Star Delta Electronicthermal Overload Relay- With Relay Range 20-50 Direct / Ct Operated Suitable-Rangeaux Coil Voltage Wide Band Fitted With Seperate Stabilization Unit Min 1Kw Aux Wiringf ) . Auxillary Mccb =63 Ampwith S.C. Breaking Capacity Of36kag ) . Motor Protection Relay Suitablei ) M-Power Module For Mobile Starter & Earth Fault Relay J ) Water Level Controller Rest Of Deatils / Technical Specification Are As Per Clause 43 Ofannexure C Of Sbd 35 Providing, Installation And Testing Ofheavy Duty Manual Type Triple Spur Gear Chainpulley Block Along With Monorail Geared Travelling Trolley Having Followingfeaturesmake = Reputed Make Capacity = 3 Ton ( P ) No. Of Load Chain Falls = 2 Or Above Min. Height Of Lift = 6 Mrest Details / Specification As Per Clause 24 Of Annexure C Of Sbd 36 Illumination Of Premises:Providing And Erection Of 9 Mtr Long Hot Dip Galvanized Octagonal Pole Rest Of Deatils / Technical Specification Are As Per Clause 50 Ofannexure C Of Sbd 37 Providing, Installation, Testing And Commissioning Of Area Lighting 120 Watt Led ( Street Light Type ) On Top Of Octagonal Pole , Including Mcb Fiited In Box 10Arest Details / Specification As Per Clause 51 Of Annexure C Of Sbd 38 Providing And Installation Of Junction Box With Dp 32Amp Mcb To Serve As Amin Switch For Led Lighting Including Complete Wiring Min 20-30 M From Panel Board.Rest Details / Specification As Per Clause 52 Of Annexure C Of Sbd 39 Providing, Installation And Testing Of 2Kva Fully Automatic Voltage Stabilizer , Including Wiringrest Details / Specification As Per Clause 53 Of Annexure C Of Sbd 40 Providing & Fitting Oflighting Points For ( Machine Room , Operators Room, ) As Per Site Requirement In 1.5 Mm² Multistranded Single Core 1100 Volts, Pvc Insulatedcopper Conductor Through Pvcconduit Pipe By Way, Switches, Socket Modules , Regulators , Indicators, 08 / 10 Watt Led Lamps Surface Light Make. .Included Is Cost On Account Of Modular Switch Boards With The Wooden Frames As Per Site Requirements 41 Providing Fitting Of Heating Points In 2.5Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit By Way Of P / F Of 15 Amp Switches, 6 Pin Socketon Modularfittingas Per Site Requirements. Heating Points Are To Be Connected From Main Control Panel. All Accessories Required Is To Be Provided By The Firm 42 Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. Make Providing And Fitting Of 9” X 9”Exhaust Fan With Complete Wiring In 1.5 Mm Cu Wire Through Conduit And 6 A Modular Controlcomplete Job. 43 Providing, Fitting Of Distribution Board Of Reputed Make 4 Way S P N Single Door Powder Coated Sheet Steel Enclosure For Surface Mounting Fitted With Bus Bar, Din Channel, Neutral Link And Incoming Contact. The Above Db Is To Be Provided / Fitted With Double Pole 40 Amp Mcb For Main. 32 A For Heating Circuit & Rest 3 Of 16 / 6 Amps Each For Premises Luminary, Auxiliary Circuit Of Reputed Make. Further Job Includes Providing / Fitting 4 Mm² Multistranded Single Core 1100 Volts, Pvc Insulated Copper Conductor Through Pvc Conduit As Service Line From Main Panel As Per Site Requirements. Connections Should Be Made In Such A Way Lighting Pointsis To Be Connected Via Automatic Transformer By Way Of P / F Switch Socket Arrangement With Allied Fixtures & And Heating Points To Main Panel. Job Includes Dismantling Of Existing Damaged Conduit , Wires, Conduit And Cleaning The Surface Properly 44 Earthing Of Panel Boad, Stabilizer, Motors, Heating Points, Lighting Points, D.G Setsrest Details As Per Clause 48 Of Annexure C Of Sbd 45 Painting On Steel Structure / Pipe With Synthetic Enamel Paint Of Approved Brand And Maufacturer Of Required Colour To Give An Even Shade On New Work ( Two Or More Coats ) Including A Coat Of Approved Steel Primer But Excluding A Coat Of Mordant Solution. ( Ref 13.61 ) Schedule2021 46 Fabrication, Providing, Fitting Of Base Framefor Pumping Units , Covering Of Holes , Fabrication Of Gantry, Ladder , Dg Set Covering, Ht / Lt Transformer Bed With Gantry Fabricated Out Of Ismc / Ismb / Isa / Bars / Ms Pipe / Ms Plain-Chequrred Sheets. Including Making Of Holes In Concrete, Including Metal Primer 1 Coat And Two Coats Of Approved Shade . The Works Is To Be Executed As Per Site Requirement And As Per Dimentions Of Pumping Unit And As Per Directions Of Site Engineer.Rest Of Specification / Details Are As Per Clause 21 Of Annexure C Of Sbd 47 Providing And Laying In Position Cement Concrete Of Specified Grade Including Curing But Excluding The Cost Of Centring And Shuttering. All Work Upto Plinth Level 1:2:4 With Stone Aggregrate 20 Mm Nominal Size. For Dg Set Foundatioin / Concrete Beds For Rising-Main As Per Requirement 48 Centering And Shuttering Including Strutting, Propping Etc And Removal Of Form Work For Foundation, Footing , Base 49 Earth Work In Excavation By Manualmeans In Trenches For Foundations, Drains , Pipes , Cables Etc ( Not Exceeding 1.5 M In Width ) Andramming Of Bottoms Lift 1.5 M , Including Getting Out Excavated Earth And Disposal Of Surplus Exacavated Earth As Directed ( All Kinds Of Soil ) ( 2.81 Schedule ) 50 Providing And Laying Of Soling Stone 51 Cement Plaster In Find Sand In 1:3 Mix Finished With A Coat Of Neat Cement And Curing Complete 18 Mm Thick. ( S-11.8 ) 52 Providing, Laying & Fixing With Adhesive / Bonding Material Of Insulation Rubber Mats On The Floor Of The Pump House, Covering Area Around Electro-Mechanical Machinery For Safeguarding The Life & Limb Of The Workmen . Rest Details / Specification As Per Clause 55Of Annexure C Of Sbd 53 Tool Kit For Maintenance: -The Tool Kit For Maintenance As Per Detailed Specification In Clause 56 Of Annexure C Of Sbd 54 Providing Of Good Quality Conveinence And Utility Items As Per Details In Clause57 Of Annexure C Of Sbd 55 Fabricationof6’ X 6’ Angle Iron Bedfor Operators. Rest Details / Specification As Per Clause 58 Of Annexure C Of Sbd 56 Providing And Fitting Of 19 Mm Thick Multilayered Ply Sheet Of Size 6 X 3 Feet , 2 Nos. Rest Details / Specification As Per Clause 59 Of Annexure C Of Sbd 57 Providing Of Solar / Electrical Lantern Chargeable On Both Solar & Electrical 220V Supply.Rest Details / Specification As Per Clause 60 Of Annexure C Of Sbd 58 Providing Of 1 Kw Heat Convector For Operators For Winter Season.Rest Details / Specification As Per Clause 62 Of Annexure C Of Sbd 59 Providing And Fitting Of 01 No. Led ( Scroll Type ) Sign Board Fabricated Out Of Stainless Steel And Metalrest Of Deatils / Technical Specification Are As Per Clause 63 Of Annexure C Of Sbd 60 Providing And Fitting Of 01 No. Angle Iron / Sheet Metal Board Duly Painted Showing Various Specifications Of The Mechanical And Electrical Equipments Installed At Site. The Legs Are To Be Grouted In Cement Concrete.Rest Of Deatils / Technical Specification Are As Per Clause 64 Of Annexure C Of Sbd 61 Civil Works 62 Earth Work In Excavation By Mannual Means Over Areas ( Exceeding 30Cm And Upto 1.5M In Depth And Width As Well As 10 Sqm In Plan ) Including Disposal Of Excavated Earth Upto 1M Cutting Edge, Disposed Earth To Be Levelled And Neatly Dressed For Foundations 63 Extra For Earthwork In Excavation Beyond 1.5M 64 Providing And Laying Of Dry Stone Soling In Horizontal On Level. 65 Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centering And Shuttering.1:4:8 ( 1 Cement : 4 Coarse Sand : 8 Graded Stone Agg. 40 Mm Nominal Size Crushed 66 Reinforced Cement Concrete Work In Walls ( Any Thickness ) Including Attached Pilasters, Buttresses, Plinth And String Courses, Fillets, Columns, Pillars, Piers, Abutments, Posts And Struts Upto Floor Five Level Including Curing But Excluding Cost Of Centering Shuttering, Finishing And Reinforcement.1:1½:3 ( 1 Cement : 1½ Coarse Sand : 3 Graded Stone Aggregate 20 Mm Nominal Size ) 67 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.All Works Upto Plinth Level . 68 Providing And Laying In Position Machine Batched And Machine Mixed Design Mix M-25 Grade Cement Concrete For Reinforced Cement Concrete Work, Using Cement Content As Per Approved Design Mix, Including Pumping Of Concrete To Site Of Laying But Excluding The Cost Of Centering, Shuttering, Finishing And Reinforcement, Including Admixtures In Recommended Proportions As Per Is: 9103 To Accelerate, Retard Setting Of Concrete, Improve Workability Without Impairing Strength And Durability As Per Direction Of Engineer-Incharge.All Works Above Plinth Level . 69 Centering And Shuttering Including Strutting, Propping Etc, And Removal Of Form Work For Foundations, Footings, Bases For Columns 70 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Walls ( Any Thickness ) Including Attached Pilasters Buttresses, Plinth And String Course Fillets, Kerbs And Steps Etc. 71 Centring And Shuttering Including Strutting, Propping Etc, And Removal Of Form Work For Suspended Floors 72 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Lintel , Beams & Cantilevers Etc 73 Centering And Shuttering Including Strutting, Propping Etc. And Removal Of Form For: Columns 74 Extra For Shuttering In Circular Workfor Foundations, Footings, Bases For Columns 75 Extra For Shuttering In Circular Workfor Suspended Floors 76 Extra For Shuttering In Circular Workfor Walls 77 Extra For Shuttering In Circular Work For Lintels, Beams & Cantilevers 78 Finishing Walls With Water Proofing Cement Paint Of Required Shade On New Work ( Two Or More Coats Applied @ 3.84 Kg / 10Sqm ) 79 Applying Priming Coat:With Ready Mixed Pink Or Grey Primer Of Approved Brand And Manufacture On Wood Work ( Hard And Soft Wood ) 80 Painting With Synthetic Enamel Paint Of Approved Brand And Manufacture To Give An Even Shade Two Or More Coats. 81 Reinforcement For Rcc Work Including Straightning, Cutting, Bending, Binding. T.M.T Bars 82 Providing And Mixing Water Proofing Material In Cement Concrete Work In Doses By Weight Of Cement As Per Manufacturer’S Specification. ( 1 Kg Of Water Proofing Material In 50 Kg Of Cement ) 83 Brick Work In Fps Bricksof Class Designation 75 In Foundation And Plinth In Cement Mortor 1:4 Mix 84 Extra For Brick Work With Common Burnt Clay Bricks / Cement Concrete Bricks Insuperstructure Above Plinth Level Upto Floor Five Level 85 Providing And Fixing Panelled Or Panelled And Glazed Shutters For Doors, Windows And Clerestory Windows Fixing With Butt Hinges Of Required Size With Necessary Screws, Excluding Panelling Which Will Be Paid For Separately, All Complete As Per Direction Of Engineer-In-Charge, Using First Class Kail Wood 35Mm Thick. 86 Providing Wood Work In Frames Of Doors, Windows, Clerestory Windows And Other Frames, Wrought Framed And Fixed In Position With Hold Fast Lugs Or With Dash Fasteners Of Required Dia And Length ( Hold Fast Lugs Or With Dash Fasteners Shall Be Paid For Separately ) Ist Class Kail Wood 87 Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) . Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40Mm Thick. For Door 88 Providing And Fixing Panelling Or Panelling And Glazing In Panelled Or Paneled And Glazed Shutters For Doors, Windows And Clerestory Windows ( Area Of Opening For Panel Inserts Excluding Portion Inside Grooves Or Rebates To Be Measured ) . Panelling For Panelled Or Panelled And Glazed Shutters 25 Mm To 40Mm Thick. For Glass Panes 4Mm Thick For Exterior Window Shutters 89 C ) Fly Proof Stainless Steel Grade 304 Wire Gauge With 0.5 Mm Dia Wire And 1.4 Mm Wide Aperture With Matching Wood Beading 90 12Mm Thick Cement Sand Plaster Finished With A Floating Coat Neat Cement Of Mix 1:3 91 Extra For Plastering On Circular Work One Coat. 92 Filling Available Excavated Earth ( Excluding Rock ) In Trenches, Plinth, Sides Of Foundations Etc. In Layers Not Exceeding 20 Cm In Depth, Consolidating Each Deposited Layer By Ramming And Watering, Lead Upto 50 M And Lift Upto 1.5 M 93 Carriage Of Material By Mechanical Transport 94 Cement & Steel Avg Lead 15 Km 95 Sand & 20Mm Agg. For Average Lead Of 56Km 96 Bajree For Average Lead Of 56 Km 97 Stone Soling For 56 Km 98 Bricks For Average 80 Km

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 17-Oct-2022 Extension of bid Date 24-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 124360.0 /-
Tender Value
INR 62.18 Lakhs /-

BOQ Items

Name of Work:Electro-mechanical and civil works to be carried at Water supply Scheme Baba Shakrudin under JJM Estimated cost: Rs 62.18 Lacs
Sl. No. Item Description
1Electrical Mechanical works
2Providing, fitting, installation, testing and commissioning of VT pumping unit of approved make withfollowing specifications: at Stage 1st Discharge of the Pump = 5000 GPH Dynamic Head = 70 M Speed = 1450 RPM Working Voltage = 380 ± 15 V, 03 phaseRating = Corresponding to the head and discharge not less than 15HP. Rest of Specification/Details are as per clause 6 of Annexure "C" of SBD
3Providing/supplying and fitting ofG.I flanged Rising Main at site. The Pipe shall be hot dip Galvanized, class-C confirming to IS 1239. The job includes providing and fitting of M.S Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) for Y junction and washout Size: 80 mm dia Class:C (Heavy) Rest of Specification as per clause 8 of Annexure "C" of SBD
4Cutting of hot dip galvanized GI , C-Class pipe acoss the section by dint of pipe cutter/gas cutter. The job includes providing and welding of M.S. Flanges to the two ends of Pipe. The Thickness of flange shall conform to IS 6392 Part 1st Table-17 Dia: 80 mm Rest of Specification as per clause 11 of Annexure "C" of SBD
5Fabrication , providing and fiting of Y- Junction havingminimum 1m arm length of each arm to be fabricated out of G.I C class pipe with M.S. Flanges conforming to BIS 6392/1997 Table 17 (Rating PN16) Fastened with weld joints on three ends. Dia: 80 mm Rest of Specification as per clause 8 of Annexure "C" of SBD
6Providing and fitting of, Ductile Iron double flanged, non-rising spindle soft seatedglandless gate/ sluice valves as per IS14846 for regulating the water supply outside the pumping units . Size: DN80 PN:1.6/16 Rest of Specification/Details areas per clause 12 of Annexure "C" of SBD
7Providing and fitting ofDuctile Iron double flanged, Slanted seatswing check valve( NRV) as per IS 5312. Size: 80mm PN: 1.6/16Rest of Specification/Details areas per clause 13 of Annexure "C" of SBD
8Providing and fitting of 80 mm dia flanged flanged bends/elbolw to delivery mainfold and washout, including nuts and bolts and rubber gaskets as per requirement. Rest of Specification/Details areas per clause 15 of Annexure "C" of SBD
9Providing and fitting of flanged Washout Tee 80 mm ,including nuts,bolts and gasket as per site requirement. Rest of Specification/Details areas per clause 09 of Annexure "C" of SBD
10Supply installation , testing and commissioning of level II HT Transfromer Capacity: 63 KvA Rest of Specification/Details areas per clause 26 of Annexure "C" of SBD
119 m Long ST-410 SP33 pole Rest details as per clause 32 of Annexure "C" of SBD
1213 m Long ST-410 SP33 pole Rest details as per clause 32 of Annexure "C" of SBD
13Cement Bottoming 1:2:4 mix as per REC standards 0.5 cum/pole
14G.I V cross with top Bracket including clamps Rest details as per clause 32 of Annexure "C" of SBD
1511 KvA Polymeric Insulators12 kV ,5kN , Lighting impulse 75 kV Positive and 80 kV Negative with creepage distance 320mm Rest details as per clause 31 of Annexure "C" of SBD
16Galvanized nuts and bolts (1kg/pole) Rest details as per clause 33 of Annexure "C" of SBD
17Danger plate with clamps Rest details as per clause 34 of Annexure "C" of SBD
18Anti climbing Device with clamps Rest details as per clause 35 of Annexure "C" of SBD
19Red Oxide coating Rest details as per clause 37 of Annexure "C" of SBD
20Alumunium Paint coating Rest details as per clause 38 of Annexure "C" of SBD
21Stone pad (300mm x300mm x75mm) Rest details as per clauseof Annexure "C" of SBD
22PG Clamps fo 50 sqmm ACSR conductor
23ACSR conductor 50 sqmm Rest details as per clause 39 of Annexure "C" of SBD
24GI Channel/Angle/Flat of sizes including clamps
2511 KvA GO , AB Switch 3 Phase, 3 Pole, 200 A, Vertical Type Rest details as per clause 28 of Annexure "C" of SBD
2611 kV polymeric composite Disc Insulator 12 kV, Min failing load 45kN, Lighting Impulse 75kV Positive and 80 kV Negative, creepage distance 320mm
27Gapless Surge Arrrestor 9KV, 10 KA , LA with Polymer housing, Stn type Rest details as per clause 30 of Annexure "C" of SBD
28Earthing of substation- Rest details as per clause 48 of Annexure "C" of SBD
29Galvanised stay set with 50x8mm stay clam, guy insulators(2No"s), anchor plate (200x200x6mm), nuts and bolts,2 Nos; turn-buckles, 1.8m long, 16mm dia meter solid GS stay rod & 7/3.15 mm dia GI Stranded wire complete Rest details as per clause 36 of Annexure "C" of SBD
30Sundry items like Alumunium Lugs , Jumprs, binding Tape
31Providing & Fitting of35 sq mm Single Core Copper Conductor (Flexible) PVC Insulated Heavy Duty Industrial Cables (Unsheathed), 1100 Volts Conforming to IS: 694- for connecting motors from panel , stabilizers in rubber conduit . Job includes providing& laying of flexible conduit for cu cable with lugs as per requirement Heat Shrinkable Outdoor cable termination Kit Rest details as per clause 73 of Annexure "C" of SBD
32Providing, installation ,testing of power service cablefor workingvoltage up to and including 1100 volts;95 sq mm armored aluminum 3.5 core cable as service line from output terminals of HT/LT transformerto cubical panel. Cost includes laying of cable in trenches in Pvc conduit where ever itis to be laid underground as per site requirement included is termination of ends with suitable Aluminum tube terminals dully crimpled & taped. Rest Specifications as per clause 68 of Annexure "C" of SBD
33Providing, installation, testing and commissioning of 50 KVA Voltage Stabilizer Rest details & specification as per clause 44 of Annexure "C" of SBD
34Fabrication Providing and fitting of 3 phase modular control panel. The technical details/ Ratings of various components of Modular Control Panel are given Below b. Main Circuit Breaker = 200 A c. Changeover Switch = 200 A d. Motor Breakup ProtectionMCCB= 160 A e. FASDstarter - 2 units with rating Line contactor _AC3 70 A , Delta Contactor- AC3 70 A Star Contractor- AC3 50 A Timer- Star Delta Electronic Thermal overload relay- with relay range 20-50 direct/CT operated suitable-range Aux coil voltage Wide Band fitted with seperate stabilization unit min 1KW Aux wiringf). Auxillary MCCB =63 AmpWith S.C. Breaking Capacity of36kA g). Motor Protection Relay suitable i) M-Power module for mobile starter & Earth fault relay j) Water level controller Rest of Deatils/Technical specification are as per clause 43 ofAnnexure "C" of SBD
35Providing, installation and testing ofHeavy Duty manual type triple spur gear chain pulley block along with monorail geared travelling trolley having following features Make = Reputed make Capacity = 3 ton (P) No. Of load chain falls = 2 or above Min. Height of lift = 6 M Rest details/ specification as per clause 24 of Annexure "C" of SBD
36Illumination of Premises: Providing and erection of 9 Mtr long Hot Dip Galvanized octagonal pole Rest of Deatils/Technical specification are as per clause 50 ofAnnexure "C" of SBD
37Providing, installation, testing and commissioning of area lighting 120 Watt LED (Street Light Type) on top of octagonal pole , including MCB fiited in box 10A Rest details/ specification as per clause 51 of Annexure "C" of SBD
38Providing and installation of Junction Box with DP 32Amp MCB to serve as amin switch for LED lighting including complete wiring min 20-30 m from panel board. Rest details/ specification as per clause 52 of Annexure "C" of SBD
39Providing, Installation and testing of 2KVA fully automatic voltage stabilizer , including wiringRest details/ specification as per clause 53 of Annexure "C" of SBD
40Providing & fitting oflighting points for( machine room , operators room,) as per site requirement in 1.5 mm² multistranded single core 1100 volts, pvc insulatedcopper conductor through pvcconduit pipe by way, switches, socket modules , regulators ,indicators, 08/10 watt LED lamps Surface light Make. .Included is cost on account of modular switch boards with the wooden frames as per site requirements
41Providing fitting of heating points in 2.5mm² multistranded single core 1100 volts, pvc insulated copper conductor through pvc conduit by way of p / f of 15 Amp switches, 6 pin socketon modularfittingas per site requirements. Heating points are to be connected from main control panel. All accessories required is to be provided by the firm
42Providing and fitting of 9” x 9”exhaust fan with complete wiring in 1.5 mm cu wire through conduit and 6 A modular controlcomplete job. Make Providing and fitting of 9” x 9”exhaust fan with complete wiring in 1.5 mm cu wire through conduit and 6 A modular controlcomplete job.
43Providing, fitting of Distribution Board of reputed make 4 way S P N single door powder coated sheet steel enclosure for surface mounting fitted with bus bar, DIN channel, neutral link and incoming contact. the above DB is to be provided /fitted with double pole 40 amp MCB for Main. 32 A for heating circuit & rest 3 of 16/6 amps each for premises luminary, auxiliary circuit of reputed make. Further job includes providing / fitting 4 mm² multistranded single core 1100 volts, pvc insulated copper conductor through pvc conduit as service line from main panel as per site requirements. Connections should be made in such a way Lighting pointsis to be connected via automatic transformer by way of p/f switch socket arrangement with allied fixtures & and heating points to main panel. Job includes dismantling of existing damaged conduit , wires, conduit and cleaning the surface properly
44Earthing of Panel boad, stabilizer, Motors, heating points, lighting points, D.G sets Rest details as per clause 48 of Annexure "C" of SBD
45Painting on steel structure/pipe with synthetic enamel paint of approved brand and maufacturer of required colour to give an even shade on new work( Two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. (ref 13.61) schedule2021
46Fabrication, providing, fitting of base framefor pumping units , covering of holes , fabrication of gantry, ladder ,DG set covering, HT/Lt transformer Bed with gantry fabricated out of ISMC/ISMB/ISA/Bars/MS Pipe/MS plain-chequrred Sheets. Including making of holes in concrete, including metal primer 1 coat and two coats of approved shade . The works is to be executed as per site requirement and as per dimentions of Pumping unit and as per directions of site engineer. Rest of Specification/Details are as per clause 21 of Annexure "C" of SBD
47Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level 1:2:4 with stone aggregrate 20 mm nominal size. For DG Set foundatioin /concrete beds for rising-main as per requirement
48Centering and shuttering including strutting, propping etc and removal of form work for foundation, footing , base
49Earth work in excavation by manualmeans in trenches for foundations, drains , pipes , cables etc (Not exceeding 1.5 m in width) andramming of bottoms lift 1.5 m , including getting out excavated earth and disposal of surplus exacavated earth as directed ( All kinds of soil) (2.81 schedule)
50Providing and laying of soling stone
51Cement plaster in find sand in 1:3 mix finished with a coat of neat cement and curing complete 18 mm thick. (s-11.8)
52Providing, laying & fixing with adhesive/bonding material of insulation rubber mats on the floor of the pump house, covering area around electro-mechanical machinery for safeguarding the life & limb of the workmen . Rest details/ specification as per clause 55of Annexure "C" of SBD
53TOOL KIT For Maintenance: - The Tool Kit for maintenance as per detailed specification in clause 56 of Annexure "C" of SBD
54Providing of good quality conveinence and utility items as per details in clause57 of Annexure "C" of SBD
55Fabricationof6’ x 6’ angle iron bedfor operators. Rest details/ specification as per clause 58 of Annexure "C" of SBD
56Providing and fitting of 19 mm thick multilayered ply sheet of size 6 x 3 feet , 2 nos. Rest details/ specification as per clause 59 of Annexure "C" of SBD
57Providing of solar/ electrical lantern chargeable on both solar & electrical 220v supply. Rest details/ specification as per clause 60 of Annexure "C" of SBD
58Providing of 1 KW heat convector for operators for winter season. Rest details/ specification as per clause 62 of Annexure "C" of SBD
59Providing and fitting of 01 No. LED (scroll type) sign board fabricated out of stainless steel and metalRest of Deatils/Technical specification are as per clause 63 of Annexure "C" of SBD
60Providing and fitting of 01 No. angle iron/sheet metal board duly painted showing various specifications of the mechanical and electrical equipments installed at site. The legs are to be grouted in cement concrete.Rest of Deatils/Technical specification are as per clause 64 of Annexure "C" of SBD
61Civil works
62Earth work in excavation by mannual means over areas (exceeding 30cm and upto 1.5m in depth and width as well as 10 Sqm in Plan) including disposal of excavated earth upto 1m cutting edge, disposed earth to be levelled and neatly dressed for foundations
63Extra for earthwork in excavation beyond 1.5m
64Providing and laying of dry Stone soling in horizontal on level.
65Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering.1:4:8 (1 cement : 4 coarse sand : 8 graded stone agg. 40 mm nominal size Crushed
66Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement.1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
67Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. All works upto plinth level .
68Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-incharge. All works above plinth level .
69Centering and shuttering including strutting, propping etc, and removal of form work for Foundations, footings, bases for columns
70Centering and shuttering including strutting, propping etc. and removal of form for: walls (any thickness) including attached pilasters buttresses, plinth and string course fillets, kerbs and steps etc.
71Centring and shuttering including strutting, propping etc, and removal of form work for Suspended floors
72Centering and shuttering including strutting, propping etc. and removal of form for: Lintel , beams & cantilevers etc
73Centering and shuttering including strutting, propping etc. and removal of form for: Columns
74Extra for shuttering in circular work for Foundations, footings, bases for columns
75Extra for shuttering in circular work for Suspended floors
76Extra for shuttering in circular work for Walls
77Extra for shuttering in circular work for lintels, beams & cantilevers
78Finishing walls with water proofing cement paint of required shade on New work (two or more coats applied @ 3.84 kg/10sqm)
79Applying priming coat:With ready mixed pink or grey primer of approved brand and manufacture on wood work (hard and soft wood)
80Painting with synthetic enamel paint of approved brand and manufacture to give an even shade two or more coats.
81Reinforcement for RCC work including straightning, cutting, bending, binding. T.M.T bars
82Providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer’s specification. (1 kg of water proofing material in 50 kg of cement)
83Brick work in FPS bricksof class designation 75 in foundation and plinth in cement mortor 1:4 mix
84Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
85Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge, Using First class kail wood 35mm Thick.
86Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately) Ist Class Kail Wood
87Providing and fixing panelling or panelling and glazing in panelled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick. for Door
88Providing and fixing panelling or panelling and glazing in panelled or paneled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40mm thick. for Glass panes 4mm thick for exterior window shutters
89c)Fly proof stainless steel grade 304 wire gauge with 0.5 mm dia wire and 1.4 mm wide aperture with matching wood beading
9012mm Thick cement sand plaster finished with a floating coat neat cement of mix 1:3
91Extra For Plastering on circular work one coat.
92Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m
93Carriage of material by mechanical transport
94Cement & Steel Avg lead 15 Km
95Sand & 20mm agg. for average lead of 56Km
96Bajree for average lead of 56 Km
97Stone Soling for 56 Km
98Bricks for average 80 Km
Disclaimer :