Repair Replacement Of Lt Feeder Pillar Boxes, Apfc Panels, Lt Ht Cable, Cable Joints, Lt Poles, Service Connections And Other Connect Accessories Abns And Abos Area Under Ge Belgaum, belgaum-Karnataka

Military Engineer Services-MES has published Repair Replacement Of Lt Feeder Pillar Boxes, Apfc Panels, Lt Ht Cable, Cable Joints, Lt Poles, Service Connections And Other Connect Accessories Abns And Abos Area Under Ge Belgaum. Submission Date for this Tender is 28-10-2022. Feeder Pillar Tenders in belgaum Karnataka. Bidders can get complete Tender details and download the document.




Tender Notice

34081041
Corrigendum : Repair Replacement Of Lt Feeder Pillar Boxes, Apfc Panels, Lt Ht Cable, Cable Joints, Lt Poles, Service Connections And Other Connect Accessories Abns And Abos Area Under Ge Belgaum
Open Tender
Indian
Karnataka
belgaum
28-10-2022

Tender Details

Repair Replacement Of Lt Feeder Pillar Boxes, Apfc Panels, Lt Ht Cable, Cable Joints, Lt Poles, Service Connections And Other Connect Accessories Abns And Abos Area Under Ge Belgaum

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 06-Oct-2022 date corrigendum Date 21-10-2022
2 11-Oct-2022 Amendments of BOQ and Tender documents BOQ 21-10-2022
3 21-Oct-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 70000.0 /-
Tender Value
INR 35 Lakhs /-

BOQ Items

Name of Work:REPAIR/ REPLACEMENT OF LT FEEDER PILLAR BOXES, APFC PANELS, LT/HT CABLE, CABLE JOINTS, LT POLES, SERVICE CONNECTIONS AND OTHER CONNECT ACCESSORIES ABNS & ABOS AREA UNDER GE BELGAUM
Sl. No. Item Description
1Materials andlaying in trenches or fixing in walls/poles/under trenches or drawing through pipe XLPE insulated, screened,PVC bedded, galvanised steel strip or electric power cables ( heavy duty) with aluminium conductor, 1100 volts, grade cross sectional area 240 sq mm, 3.5 core including testing the same after laid and jointedincluding Taking out / dismantling existingold u/s service LT UG cables of any sizeandany run and making good the disturbed surface all as specified and as directed. Note:- Excavation and earth work, pipe/ cable protection willbe measured and paid separetely.
2All as per item No. 1 but cable size 185 sq mm 3.5 core all as specified and as directed.
3All as per item No. 1 but cable size 150 sq mm 3.5 core all as specified and as directed.
4All as per item No. 1 but cable size 120 sq mm 3.5 core all as specified and as directed.
5All as per item No.1 but cable size 95 sq mm 3.5 core all as specified and as directed.
6All as per item No. 1 but cable size 70 sq mm 3.5 core all as specified and as directed.
7All as per item No. 1 but cable size 50 sq mm 3.5 core all as specified and as directed.
8All as per item No. 1 but cable size 35 sq mm 3.5 core all as specified and as directed.
9All as per item No. 1 but cable size 25 sq mm 3.5 core all as specified and as directed.
10All as per item No. 1 but cable size 16 sq mm 4 core all as specified and as directed.
11All as per item No. 1 but cable size 10 sq mm 4 core all as specified and as directed.
12All as per item No. 1 but cable size 10 sq mm 2 core all as specified and as directed.
13Supply and laying in trenches or fixing in walls/poles/under treanches or drawing through pipe XLPE insulated, screened, PVC bedded, galvanised steel strip or electric power cables (heavy duty) with aluminium conductor, 11000 volts, grade cross sectional area 185 sq mm, 3 core including testing after laid and jointed including Dismantling existingold u/s service HT UG cables of any run any size & making good the disturbed surface all as specified and as directed. Note:- Excavation and earth workpipe/ cable protection shall be measured and paid separetely.
14All as per item No. 13 but cable size 120 sq mm 3 core all as specified and as directed.
15All as per item No. 13 but cable size 95 sq mm 3 core all as specified and as directed.
16Excavating in trenches n exc 1.5m wideand n exc 1.5m depth and getting out in Soft/loose soil forlaying cables, pipes, pole foundation etc. all as specified and as directed.
17Excavating in trenches n exc 1.5m wideand n exc 1.5m depth and getting out in hard/dense soil forlaying cables, pipes, pole foundation etc. all as specified and directed.
18Returning , filling in including spreading , levelling , watering , and well ramming in layers not exc, 25 cm in soft / loose soil complete all as specified and as directed .
19Removing excavated material not exc 50 m & depositing where directed at a level n exc 1.5 m above the starting point.all as specified and as directed.
20M&L for plain Cement concrete 1:2:4 type B2 using 20 mm graded stoneaggregate forfillingof road cuttings areas complete all as specified and as directed
21S & F GI tube light grade 40 mm bore fixed in walls or laid in floors / trench complete all as specified and directedwith MS clamp and nut bolts and washers etctaking down old GI tubing along with all fixing accessories all as specified and as directed.
22S & F GI tube light grade 80 mm bore laid in trenches / road / drain / fixed to wall complete all as specified and directedwith MS clamp and nut bolts and washers etc, as requiredincluding taking down old GI tubing along with all fixing accessoriesall as specified and as directed.
23S & F GI tube light grade 100 mm bore laid in trenches / road / drain / fixed to wall complete all as specified and directedwith MS clamp and nut bolts and washers etc, as requied including taking down old GI tubing along with all fixing accessoriesall as specified and as directed.
24S&F Double wall corrugated high density polymer ethyl pipe of size 63 mm outer dia with ISI marked (IS 14930- 2001 ), laid in trenches /floors & fixed on wall/ pole with & including necessary fittings such as bends, sockets & other connected accessories etc forlaying of electric cables, completeall as specified and as directed. Make - Duraline, Rex, Tirupati, Tijaria,Ketron.
25S&F Double wall corrugated high density polymer ethyl pipe of size 120 mm outer diawith ISI marked (IS 14930- 2001 ), laid in trenches /floors & fixed on wall/ pole with & including necessary fittings such as bends, sockets & other connected accessories etc forlaying of electric cables, completeall as specified and as directed. Make - Duraline, Rex, Tirupati, Tijaria,Ketron.
26Taking down exiting old u/s service LT panel and APFC Panel of any capacity of making good the disturbed surfaceall as specified and as directed.
27Fabrication,Supplying Installing, Testing & Commissioning feeder pillar box weather / verminproof outdoor type from CPRI approved manufacturer having dimensions including necessary incoming & outgoing cable connections , cable glands thimbles of required sizes , made out of MS CRCA sheet 3.00 mm thick duly powder coated paint with inner shutter & outer double door with locking arrangement both side openable on 50 x 50 x 5 mm MS angleframe fixed 300 mm above groundlevel & 450 mm below the groundgrouted in & including PCC 1:3:6 mix, type C1 (using 20 mm graded stone aggregate) factory madeall as directed & comprising of followingincluding refixing existing cables to new panels by proper lugging & cable gland as required:-
28(a) Aluminium Bus bar 600 Amps capacity forPhase and Neutral with epoxy insulated coating with colour code & insulated supports- 01 Set. (b) Digital MCCB 4 pole400 Amps 50 KA at 415 Volts with adjustable microprocessor release - 01 No (for incoming). (c) MCCB 4 pole 200 Amps 36 KA at 415 Volts - 02 No (for outgoing) ( Thermal & Magnetic Adjustable) Icu= Ics (d) MCCB 4 pole 160 Amps 36 KA at 415 Volts - 02 No (for outgoing) ( Thermal & Magnetic Adjustable) Icu= Ics (e) MCCB 4 pole 100 Amps 25 KA at 415 Volts- 03 Nos (Outgoing) ( Thermal & Magnetic Adjustable) Icu= Ics. (f) MCCB 4 pole 63 Amps 25 KA at 415 Volts- 03 Nos (Outgoing) ( Thermal & Magnetic Adjustable) Icu= Ics (g)On load change over switch of size 400A capacity-01 No. (h) Phase indicator LED lamps indicating RYB - 01 Set of 3. (j)Multifunction Meter withreading Volts, Amps, Frequency, Energy, PF complete with CTs & PTs -01 Nos (k) Long Range Integrated Meter3 phase Thread through 40-200 A DLMS type integrated CT Meter with inbuilt modem in L&T
29Supplying and laying synthetic Rubber insulated mats of sizes 2m x 1mand2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006, (superseding IS 5424) suitable for electrical shock safety complete all as specified and as directed
30All as per item No. 28 but rubber insulated mat of size 2.5 mm thick for voltage upto 11 kv (size 2x1m) complete all as specified and as directed.
31Earthing complete with galvanised steel earth plate electrode 60cmx 60cmx 6.3mm burried directly in ground vertically(earth pit not less than 2.25 metre deep below normal ground level) with top edge of the earth plate at a depth not less than 1.5m below normal ground level connected to GIstrip of size 32x6mm(upto 7.5m long)by means of GI nuts, bolts and washers and 50 mm dia GI pipe light grade for protection of earth lead and 20mm dia GI pipe medium grade (upto 7.5m long) for watering arrangement and GI funnel all as specified and shown in Electrical Plate No 3 of MES Schedule Part I including necessary excavation and earth work in any type of soil, charcoal, dust salt, PCC 1:2:4 type B1 in chamber, 40mm thick RCC 1:2:4 type B1 in cover slab with 8mm dia TMT bars at 100mm C/C both ways and with 8mm dia MS hook complete and testing all as specified and directed.
32M&L in repairs for Cable jointing kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 16 sqmm to 35 sqmm.complete all as specified and as directed
33All as per item No. 31 but cable size 50sq mm to 95 Sq mm core complete all as specified and as directed.
34All as per item No. 31 but cable size 120 sq mm to 185 Sq mm core complete all as specified and as directed.
35M&L for steel tubular swaged poles complete with mild steel base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP-31 (9.00 metres long) includingdismantling existingold u/s LT Poles of any size & making good the disturbed surface complete all as specified and as directed. Notes: Excavation, earthwork, foundation concrete and coping shall be measured and paid separately under relevant items of this Schedule.
36M&L for plain Cement concrete 1:4:8 type D2 using 40 mm graded stoneaggregate forfoundation of poles complete all as specified and as directed.
37M&L for plain Cement concrete 1:3:6 type C2 using 40 mm graded stoneaggregate forfoundation of poles complete all as specified and as directed.
38S&F in repairs Sheet Moulding Compound (SMC) Junction box, 300x200x105 mm internal size, off white colour, with front hinged type door and locking arrangement with and including provision of 1 No. of 8 way bakelite connector terminal block suitable for 3 phase cable upto 16 sqmm size and provision of 1 No. of MCB SP 6-32 Amps, box fixed on pole/ wall with suitable clamps, bolts and nuts all as specified and as directed. Make: SINTEX or equivalent
39S&F in repairs street light bracket made out of GI pipe light grade 40 mm dia not less than 1.20 metres in length and bent to shape fixed to walls/ poles with suitable MS clamps, bolt, nuts etc. complete all as specified and as directed.
40Supply, Install, connect, test and commission in repairs, MICRO PROCESSOR BASED AUTOMATIC POWER FACTOR CORRECTION SYSTEM (MPFCS) Panel Board, out door weather and vermin proof type, factory fabricated out of 3 mm thick CRCA sheet duly powder coated of suitable size, medium channel 75 mm base mounting frame, installed on PCC pillars, complete internally prewired with suitable size copper conductor PVC insulated cables 1100 volts grade comprising the following for :-
41(i)MCCB 4 pole 200 A 25 KA at 415 V -01 nos (Incoming)(Thermal & Magnetic Adjustable) ICU = ICS (ii) Micro processor based automatic power factor correction system, on site programmable and capable of detecting wrong transformer connections, comprising contactors and relays suitable for capacitive switching of AC3 contactor and having current limiting resistors. (iii) MCB"s, Triple pole of suitable current capacity, 10 KA rupturing capacity, with HRC fuses for back up protection. (iv) Gas Filled heavy duty capacitor bank, AC, three phase, 415 volts, 50 Hz, consisting of number switching sequences, suitable for 10% over voltage and 30% over current having power loss less than 0.5 watts per KVAR with discharge resistors. Capacity of capacitor bank -100 KVAR ( 5 KVAR- 4 nos ,10 KVAR -4 Nos, 20 KVAR -2 Nos) (v) Digital type multi function meter of size 96 mm x 96 mm to measure current, voltage, frequency, and Power factor with built in selector switch and having programmable CT ratio.