Jal Jeevan mission - 2022-2023 - WSS to Mala and adjoining Grama Panchayaths – BWSS to Vellangallur Grama Panchayath – North zone in Thrissur District
Tender Value
6.65 Crore
Estimated cost
Bid Submission
14 Oct 2022
0 days left
EMD
2 Lakhs
Bank guarantee accepted
Document Fee
10000
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
vellangallur → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Jal Jeevan mission - 2022-2023 - WSS to Mala and adjoining Grama Panchayaths – BWSS to Vellangallur Grama Panchayath – North zone in Thrissur District
BOQ
| Sl. No. | Item Description |
| 1 | PART A |
| 2 | Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC /HDPE mains up to 110 mm dia., up to a length of 5 m using 20mm Indian Standard Class 6 uPVC pipeand uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA, FTA, couplers,PVC Service Saddle of suitable size etc. and connecting with the mains, testing the joints etc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trenchof average cross section 0.3m x 0.75m for laying connection pipe and service pipe, fixing water meter,lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet watermeter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x 200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and as per the direction of the departmental officers. |
| 3 | Providing 15mm (1/2 inch) house connection with 15mm (1/2 inch) water meter from existing PVC /HDPE mains from 140mm to 200mm dia., up to a length of 5 m using 20mm Indian Standard Class 6uPVC pipe and uPVC / GM / Brass specials viz. brass ferrule, GM full way wheel valve, Elbow, MTA,FTA, couplers, PVC Service Saddle of suitable size etc. and connecting with the mains, testing the jointsetc. complete including trenching and refilling in all kinds of soil up to a depth of 1.50m for main line tracing and trench of average cross section 0.3m x 0.75m for laying connection pipe and service pipe,fixing water meter, lighting, watching, providing caution boards, traffic control etc. complete including cost of materials, hire for tools, cost of consumables and labour charges, including the cost of tested Class B Multijet water meter with ISI mark and weather resistant PP / PE meter box of minimum size 300mm x200mm x 150mm, but excluding charges for cutting the concrete / tarred / bituminous roads etc, and asper the direction of the departmental officers. |
| 4 | Providing 20mm (1/2 inch) PVC Air Valve in the water meter assembly for 15mm connection, using20mm Indian Standard Class 6 uPVC pipes and specials including cost of materials, consumables, hire for tools and labour charges etc. complete and as per the directions of the department officers. |
| 5 | Providing 15mm PVC Tap in the water meter assembly for 15mm connection, using 20mm IndianStandard Class 6 uPVC pipes and specials including cost of materials, consumables, hire charges for tools and labour charges etc. complete and as per the direction of departmental officers. |
| 6 | Supply of uPVC Pipe, IS 4985: 2000, 6kg/cm2, 63mm Dia. |
| 7 | Supply and fixing of uPVC Pipe, IS 4985: 2000, 6kg/cm2, 63mm Dia. as stand pipe for house connection of length 1.3m with 63 mm dia End cap |
| 8 | Providing additional length of house connection pipe using 20mm Indian Standard Class 6 uPVC pipeand specials and testing the joints etc., by trenching and refilling in all kinds of soil with trench of averagecross section 0.3m x 0.75m for laying of connection pipe and service pipe, lighting, watching, providingcaution boards, traffic control etc., including cost of materials, hire for tools, cost of consumables and labour charges etc. complete, but excluding the cost of cutting of concrete / tarred / bituminous roadsetc., and as per the directions of the department officers. |
| 9 | Repair work for 1m to 2m length in 15 mm (1/2 inch) house connections, using 20mm Indian StandardClass 6 uPVC pipe and specials, including trenching and refilling in all kinds of soil, hire for tools, cost ofconsumables and labour charges, cost of materials, including charges for lighting, watching, providing caution boards, traffic control etc. complete, but excluding the cost of cutting of concrete / tarred /bituminous roads and as per the directions of the department officers. |
| 10 | Supply of uPVC Pipe, IS 4985: 2000, 10kg/cm2, 25mm. |
| 11 | Supply of uPVC Pipe, IS 4985: 2000, 10kg/cm2, 32mm Dia. |
| 12 | Supply of uPVC Pipe, IS 4985: 2000, 6kg/cm2, 40mm Dia. |
| 13 | Supply of uPVC Pipe, IS 4985: 2000, 6kg/cm2, 50mm Dia. |
| 14 | Supply of uPVC Pipe, IS 4985: 2000, 6kg/cm2, 75mm Dia.. |
| 15 | Supply of uPVC Pipe, IS 4985: 2000, 6kg/cm2, 90mm Dia. |
| 16 | Supply of uPVC Pipe, IS 4985: 2000, 6kg/cm2, 110mm Dia. |
| 17 | Supply of uPVC Pipe, IS 4985: 2000, 6kg/cm2, 140mm Dia. |
| 18 | Supply of uPVC Pipe, IS 4985: 2000, 6kg/cm2, 160mm Dia. |
| 19 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, anddressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, andthen returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within alead of 50 m : All kinds of soil |
| 20 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m :\"Ordinary Rock. |
| 21 | \"Excavating trenches of required width for pipes, cables, etc including excavation for sockets, anddressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, andthen returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : Medium Rock (blasting prohibited) |
| 22 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and layingcharges of specialsof class as that of pipe).25 mm nominal outer dia pipes. |
| 23 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and layingcharges of specialsof class as that of pipe) 32 mm nominal outer dia pipes. |
| 24 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and layingcharges of specials of class as that of pipe).40 mm nominal outer dia pipes. |
| 25 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and layingcharges of specialsof class as that of pipe) 50 mm nominal outer dia pipes. |
| 26 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and layingcharges of specialsof class as that of pipe). 63 mm nominal outer dia pipes. |
| 27 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and layingcharges of specialsof class as that of pipe) 75 mm nominal outer dia pipes. |
| 28 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and layingcharges of specialsof class as that of pipe). 90 mm nominal outer dia pipes.\" |
| 29 | laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (including supply and layingcharges of specials of class as that of pipe) 110 mm nominal outer dia pipes. |
| 30 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressureincluding supply and layingcharges of specials of class as that of pipe) 140 mm nominal outer dia pipes. |
| 31 | Laying UPVC pipes of class 2 to class 6 and specials, lowering to the trenches already made, placing in position aligning the pipe line to the lines and levels and jointing the pipes and specials with solvent cement and testing the pipe line with water to the required test pressure (ncluding supply and layingcharges of specialsof class as that of pipe).160 mm nominal outer dia pipes. |
| 32 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 25 mm dia nominal bore (Medium) |
| 33 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 32 mm dia nominal bore (Medium) |
| 34 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 40 mm dia nominal bore (Medium) |
| 35 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. Externalwork 50 mm dia nominal bore (Medium) |
| 36 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 65 mm dia nominal bore (Medium) |
| 37 | Providing and fixing G.I. pipes complete with G.I fittings including trenching and refilling etc. External work 80 mm dia nominal bore (Medium) |
| 38 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 32 mmnominal bore |
| 39 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :40 mmnominal bore |
| 40 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 50 mm nominal bore |
| 41 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 65 mm nominal bore |
| 42 | Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore |
| 43 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6, Size 100mm. |
| 44 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6,Size 125mm. |
| 45 | Supply of CI Double Flanged Sluice Valve Conforming to IS 14846 - 2000, Sluice Valve with Cap PN 1.6,Size 150mm. |
| 46 | Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 100 mm diameter. Class II\" |
| 47 | Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 125 mm diameter. Class II\" |
| 48 | Conveying and fixing C.I. sluice valves (with cap) by providing complete with bolts, nuts, rubber insertions etc. excluding the cost of valve (the tail pieces if required will be paid separately) : 150 mm diameter. Class II\" |
| 49 | Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS2, Size 80mm. |
| 50 | Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS2, Size 100mm. |
| 51 | Supply of CI Air Valve with Flanges, Conforming to IS 14845 - 2000, Kinetic Air Valve Type DS2, Size 150mm. |
| 52 | Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 80 mm Double acting Air Valve |
| 53 | Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc .excluding the cost of air valve(the tail pieces if required will be paid seperately): 100 mm Double acting Air Valve |
| 54 | Conveying and fixing C I Single acting Air Valve of approved quality with bolts,nuts,rubber insertions etc . excluding the cost of air valve(the tail pieces if required will be paid seperately): 150 mm Double acting Air Valve |
| 55 | Constructing masonry chamber 30x30x50 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for stop cock, with C.I. surface box 100x100x75 mm (inside) with hinged cover fixed in cement concrete slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 56 | Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5 |
| 57 | Constructing masonry chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand: 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 58 | Constructing masonry chamber 120x120x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 grades stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as perstandard design:With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 59 | Cutting the bituminous / concrete roads with cutting machine for a minimum depth of 200mm along the sides of proposed alignment of the pipe to be laid without causing any damage to other utilities, including the charges for hire and conveyance of tools and plant, cost of consumables and charges for lighting, watching, ribbon fencing, caution boards, traffice diversion, and as per the direction of departmental officers etc. complete, before carrying out the demolition of bituminous / concrete road by mechanical means and carrying out the excavation. |
| 60 | Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) |
| 61 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:2:4 (cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size)- for road restoration, house connection platform concrete etc |
| 62 | Centering and shuttering including strutting, propping etc. and removal of form work for:Foundations, footings, bases for columns |
| 63 | Dismantling manually / by mechanical means including stacking of serviceable material and disposal ofunserviceable material within 50 metres lead as per direction of Engineer -in-Charge:Bituminous road |
| 64 | Fencing one side of trenches, 1.50 m height with two rows of 10 cm plastic caution tape in vertical casuarina pole (girth 15cm to 24cm) fixed at 2 m intervals. |
| 65 | PART B |
| 66 | Surveying with Electronic Total Station with single prism in normal terrain and normal traffic |
| 67 | Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth, including consolidatingeach deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 mAll kinds of soil |
| 68 | Conducting field inspection,analyzing the survey results and other collected data ,collected during field inspection,designing the pipe line networks using the EPANET for providing hydraulically feasible FHTCs by engaging technically qualified experts including cost of all conveyance,hire and labour charges for computer software,printing charges etc complete. |
AI Tender Summary
Tender Timeline
Sep 23, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedOct 14, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 18, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender