Electrical Repairing Work To Be Carried Out In Central Science Library, University Of Delhi . - Supplying And Fixing Suitable Size G.I. Box With Modular Plate And Cover In Front Or In Recess Including Providng And Fixing 25A Modular Socket Outle, Delhi-Delhi

Delhi University has published Electrical Repairing Work To Be Carried Out In Central Science Library, University Of Delhi . - Supplying And Fixing Suitable Size G.I. Box With Modular Plate And Cover In Front Or In Recess Including Providng And Fixing 25A Modular Socket Outle. Submission Date for this Tender is 10-10-2022. Cushioning Supplies Tenders in Delhi Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

34069727
Electrical Repairing Work To Be Carried Out In Central Science Library, University Of Delhi . - Supplying And Fixing Suitable Size G.I. Box With Modular Plate And Cover In Front Or In Recess Including Providng And Fixing 25A Modular Socket Outle
Open Tender
Indian
Delhi
Delhi
10-10-2022

Tender Details

Electrical Repairing Work To Be Carried Out In Central Science Library, University Of Delhi . - Supplying And Fixing Suitable Size G.I. Box With Modular Plate And Cover In Front Or In Recess Including Providng And Fixing 25A Modular Socket Outlet And 25A Modular Sp Mcb C Curve Including Connectios, Painting Etc. As Required. 2 Supplying And Drawing Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In The Existing Surface / Recessed Steel / Pvc Conduit As Required. 3 1 X 1.5 Sqmm 4 2 X 6 Sq.Mm 5 Supplying And Fixing Of Following Sizes Of Heavy Dutypvc Conduit Along With Accessories In Surface / Recess Including Cutting The Wall And Making Good The Same In Case Of Recessed Conduit As Required. 25 Mm 6 Wiring For Circuit / Submain Wiring Alongwith Earth Wire With The Following Sizes Of Frls Pvc Insulated Copper Conductor, Single Core Cable In Surface / Recessed Medium Class Pvc Conduit As Required 4 X 16 Sq. Mm + 2 X 16 Sq. Mm Earth Wire 7 Supplying And Fixing Of Following Ways Surface / Recess Mounting, Vertical Type, 415 Volts, Tpn Mcb Distribution Board Of Sheetsteel, Dust Protected, Duly Powder Painted, Inclusive Of 200 Amps Tinned Copper Bus Bar, Common Neutral Link, Earth Bar, Din Bar For Mounting Mcb’S ( But Without Mcb’S And Incomer ) As Required. ( Note : Vertical Type Mcb Tpdb Is Normally Used Where 3 Phase Outlets Are Required. ) 8 Supplying And Fixing 5 A To 32 A Rating, 240 / 415 V, 10 Ka, C Curve, Miniature Circuit Breaker Suitable For Inductive Load Of Following Poles In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required.Single Pole 9 Supplying And Fixing Following Rating Four Pole 415V Isolaror In The Existing Mcb Db Complete With Connections, Testing And Commissioning Etc. As Required. 63 Amps 10 S / F Of Double Box Type Fittign Complete With All Accessories I / C Making Connection Etc. As Required Tmc 501 2Xt - Led 22W P 3242 I / C Having 2 Nos. Of Stellar 20 Watts Led Tubelight In The Existing Fitting As Required. 11 S / F Of 20 Watts Stellar Bright Led Tubelight Having 2100K Lumens In The Existing Fitting I / C Making Connection Etc. As Required 12 Supplying / Installation / Testing And Commissioning Of 200 Watts Flood Light Led Fitting Having Suitable Angle Frame, Complete With All Accessories I / C Having Pressure Die Cast Aluminium Housing With High Power Led As Lighting Source And Lens Embedded Pc Cover Having Top Opening Seperate Driver Compartment With Ip66 Protection And Impact Resistance Of Ik07 With Kv Build In Spd I / C Making Connection As Required. ( Philips Make Cat ) 13 Supplying And Fixing Of Following Accessories In The Existing Street Light / Flood Light Fitting I / C Makingconnection Etc. As Required. 14 Driver Suiable For 70 Watts Fittings 15 Surge Protector 16 Supplying / Installation / Testing And Commissioning Of 70 Watts Led Street Light Fitting Complete With All Accessories I / C Having Pressure Die Cast Aluminium Housing With High Power Led As Lighting Source And Lens Embedded Pc Cover Having Top Opening Separate Driver Compartment With Ip66 Protection And Impact Resistance Of Ik07 With Kv Build In Spd I / C Making Connection As Required. ( Philips Make ) 17 S / F Of Snap-On Dlp Trunking Of 80Mmx 50 Mm With Suitable On The Existing Wall / Surface I / C Having All The Accessories Such As Flat Angle, End Caps, Internal / External Angle Etc. As Required At Site. 18 Supplying / Laying Of One Number Pvc Insulated And Pvc Sheathed / Xlpe Aluminium Cond. Power Cable Of 1.1 Kv Grade Of Following Size Direct In Ground I / C Excavation, Sand Cushioning, Protective Covering And Refilling The Trench Etc. As Required At Site. 4 X 16 Sq.Mm 19 Dismantling The Existing Accessories And Depositing The Same At Engineering Store.

Key Value

Document Fees
INR 500 /-
EMD
INR 9923.0 /-
Tender Value
INR 4.96 Lakhs /-

BOQ Items

Name of Work: Electrical repairing work to be carried out in Central Science Library,University ofDelhi.
Sl. No. Item Description
1Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providng and fixing 25A modular socket outlet and 25A modular SP MCB "C" curve including connectios, painting etc. as required.
2Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required.
31 x 1.5 sqmm
42 x 6 sq.mm
5Supplying and fixing of following sizes of Heavy dutyPVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
6Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 16 sq. mm + 2 X 16 sq. mm earth wire
7Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 volts, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 amps tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCB’s (but without MCB’s and incomer ) as required. (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.)
8Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
9Supplying and fixing following rating four pole 415V isolaror in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps
10S/F of double box type fittign complete with all accessories i/c making connection etc. as required TMC 501 2XT - LED 22W P 3242 i/c having 2 Nos. of stellar 20 watts LED tubelight in the existing fitting as required.
11S/F of 20 watts stellar bright LED tubelight having 2100K lumens in the existing fitting i/c making connection etc. as required
12Supplying / installation/ testing and commissioning of 200 watts flood light LED fitting having suitable angle frame, complete with all accessories i/c having pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening seperate driver compartment with IP66 protection and Impact resistance of IK07 with KV Build In SPD i/c making connection as required. (Philips make CAT)
13Supplying and fixing of following accessories in the existing street light / flood light fitting i/c makingconnection etc. as required.
14Driver suiable for 70 watts fittings
15Surge Protector
16Supplying/ installation/ testing and commissioning of 70 watts LED street light fitting complete with all accessories i/c having pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP opening separate driver compartment with IP66 Protection and Impact resistance of IK07 with KV Build in SPD i/c making connection as required. (Philips make)
17S/F of snap-on DLP trunking of 80mmX 50 mm with suitable on the existing wall/surface i/c having all the accessories such as Flat angle, end caps, internal/ external angle etc. as required at site.
18Supplying/ laying of one number PVC insulated and PVC sheathed/ XLPE aluminium cond. Power cable of 1.1 KV grade of following size direct in ground i/c excavation, sand cushioning, protective covering and refilling the trench etc. as required at site. 4 x 16 sq.mm
19Dismantling the existing accessories and depositing the same at Engineering store.