Re-Wiring Of Lh Tower, Ph House, Staff Quarters, Inspection Quarter, Supply And Installation Of Street Lights Poles And Ese Lighting Arrestor At Vengurla Point Lighthouse Under Goa Directorate.
Tender Value
20.13 Lakhs
Estimated cost
Bid Submission
06 Oct 2022
0 days left
EMD
40278
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
vengurla → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Re-Wiring Of Lh Tower, Ph House, Staff Quarters, Inspection Quarter, Supply And Installation Of Street Lights Poles And Ese Lighting Arrestor At Vengurla Point Lighthouse Under Goa Directorate.
BOQ
| Sl. No. | Item Description |
| 1 | Re-wiring of Lighthouse Tower at Vengurla Lighthouse - ANNEXURE – IModular Switch Boxes, Sockets and Switches |
| 2 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 3 | 3 x 1.5 sq. Mm (for fan and light points in service room and tower bottom) |
| 4 | 3 x 2.5 sq. mm(From DB to Switch Board) |
| 5 | 4 x 1.5 sq. mm(for staricase wiring From LH tower bottom to service room) |
| 6 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 7 | 5/6 A switch |
| 8 | 2 way 5/6 A switch |
| 9 | 15/16 A switch |
| 10 | 3 pin 5/6 A socket outlet |
| 11 | 6 pin 15/16 A socket outlet |
| 12 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 13 | 1 or 2 Module (75mmX75mm) (PVC) (for Wall mounted fan) |
| 14 | 3 Module (100mm * 75mm) (PVC) |
| 15 | 12 Module (200mm * 150mm) (PVC) |
| 16 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 17 | Installation, testing and commissioning of ceiling fan/wall mounting fan including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 18 | Supplying and fixing PVC batten / angle holder including connections etc. as required. (1 for lantern room) |
| 19 | Switch Gear and DB |
| 20 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 21 | Single pole 6A(1 No for service room)(2 Nos for LH bottom) |
| 22 | Single pole 16A (2 Nos LH bottom) (1 No for service room) |
| 23 | Double pole (32A)(LH Service room) |
| 24 | Supplying and fixing following rating, double pole, 240 V, isolator in the commissioning etc. as required. existing MCB DB complete with connections, testing and and commissioning etc. as required. (at service room and LH bottom) |
| 25 | 40 A (1 No for Service room, 1 No for LH bottom stair case) |
| 26 | Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. (at service room and LH bottom) |
| 27 | 40 A (1 No for Service room, 1 No for LH bottom stair case) |
| 28 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. |
| 29 | 8 way, Double door (1 Nos LH tower Service room)(1 No for LH bottom) |
| 30 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 31 | Supply of Indoor Industrial Tube Light Battens, with LED Tube (inclusive), LED Batten with Essential 4\" 22W LED tube. (refer Sl No. 1.035 for installation) |
| 32 | Supply of 10W LED Bulk Head Luminaries IP65/66/67 LED Light source (inclusive) with integrated LED source. |
| 33 | Supply of LED LAMP 12W(Base B22 12-Watt LED Bulb)dimmable Master LED Glass Bulb (refer Sl No.1.035 for installation) |
| 34 | Supply of Wall Mounting Fan, 400 millimeter Bracket mounted fan for Wall mounting (Mist Air Duos) Hi-Speed, |
| 35 | Supply of Cable ducting (base+cover) Transcab - 60 X 80 mm - PVC cable management duct for laying cable from tower bottom to Top. ( Each duct 2 mtre length.) |
| 36 | Supply of 1 inch (25X16mm)U-PVC mini trucking system each 2 mtr length (for stiar case light wiring) |
| 37 | Supply and laying of 2 core X 10 Sqmm Copper Un-armoured PVC insulated/ power cable as required.(fromPower house to Lighthouse service room main light)(light load 3000W) |
| 38 | Supply and laying of 3core X 2.5 Sqmm Copper armoured PVC insulated/PVC sheathed XLPEpower cable as required.(30 for stair case Light fro PH to Lh Bottom )+ (30 for NAIS from PH to LH bottom) |
| 39 | Supply of Bare Copper wire, 8 SWG |
| 40 | Laying of 8 SWG copper wire in cable duct from earth pit to serivce room DB & LH tower bottom DB. |
| 41 | Laying & fixing of cable duct (for vertical run) and re-ruting of Old NAIS, other cables and New cable in cable ductfrom Tower bottom to lighthouse tower top (service room) (20 meter height tower) |
| 42 | Making earth pit charges(additional) of Sl No.1.0511 for Lighthouse located at hill & rocky area diffcult to digging earth pit(heavy duty machinary and labour charges) |
| 43 | Miscellaneous items for the purchase of S.S screws and washer(for fixing cable duct), drill bits, fishers(heavy wall plugs) 250mm cable ties, SS \"U\" Clamps, flexible pipes, etc., |
| 44 | Re-wiring of Power House, Staff Quarters and Inspection Quarter at Vengurla point Lighthouse - ANNEXURE-II |
| 45 | MODULAR SWITCH BOXES, SWITCHES AND SOCKETS |
| 46 | Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. |
| 47 | 1 or 2 Module (75mm * 75mm) |
| 48 | 3 Module (100mm * 75mm) |
| 49 | 6Module (125mm * 125mm) |
| 50 | 8Module (125mm * 125mm) |
| 51 | 12 Module (200mmX150mm) |
| 52 | Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 53 | 5/6 A switch |
| 54 | 15/16 A switch |
| 55 | 3 pin 5/6 A socket outlet |
| 56 | 6 pin 15/16 A socket outlet |
| 57 | Bell push |
| 58 | Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. |
| 59 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. (fancy type) |
| 60 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 61 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 62 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. |
| 63 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 64 | CONDUIT AND CABLE |
| 65 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. conduit as required. |
| 66 | 25 mm |
| 67 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. |
| 68 | 2 x 1.5 sq. mm(for Lamp Holder) |
| 69 | 3 x 1.5 sq. mm |
| 70 | 3 x 2.5 sq. mm |
| 71 | 3 x 4 sq. mm |
| 72 | SWITCH GEAR |
| 73 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted\ including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 74 | 6 way, Double door |
| 75 | 12 way, Double door |
| 76 | 16 way, Double door |
| 77 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 78 | Single pole 10A |
| 79 | Single pole 16A |
| 80 | 25 A Triple pole and neutral (for Pump House) |
| 81 | Supplying and fixing following rating, double pole, 240 V, isolator in the commissioning etc. as required. existing MCB DB complete with connections, testing and Commissioning etc. as required. |
| 82 | 40 A |
| 83 | Supplying and fixing following rating, double pole, (single phase and neutral), 240V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 84 | 40 A |
| 85 | Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 86 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.(for power house) |
| 87 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.(NA-1 qtrs - 1 No, NA-2 Qtrs - 1 No, NA-3 Qtrs - 1 No, IQ-1 No, LHA qtrs - 2 No) |
| 88 | Supply of Indoor Industrial Tube Light Battens, with LED Tube (inclusive), LED Batten with Essential 4\" 22W LED tube. (refer Sl No.2.03 for installation) |
| 89 | Supply of Bulk Head Luminaries IP65/66/67 IK09/10 LED Light source (inclusive) with integrated LED source. (refer Sl No.8 for installation) |
| 90 | Supply of LED LAMP 12W(Base B22 12-Watt LED Bulb)dimmable Master LED Glass Bulb (refer Sl No.2.03 for installation) |
| 91 | Supply of Wall Mounting Luminaries, 7W Full Glass LED lamp B22/E27 (Non Dimmable) (refer Sl No.2.03 for installation) |
| 92 | Supply of Ceiling Fan, Electro-phoretic lacquered/ Electroplated surface for anti-rusting, High speed fan with wider tip blade for effective air circulation with Sweep 1200mm and Hight performance even at low voltage. (refer Sl No.2.02 for installation) |
| 93 | Supply of Outdoor25Watt LED COBstreet light fitting (Diecast powdercoated enclosurewith structured LED arrays and IP65/66 protectionand) |
| 94 | Providing and fixingofstreet light bend pipe1\"(inch) GI class \"C\" pipe including clamp/SS screws etc., |
| 95 | Supply of Bare Copper wire, 8 SWG earth wire (for all quarters) |
| 96 | Labour charge for laying 8 SWG wire from ground level to Distribution box through pvc pipe with clamp. |
| 97 | Supply and Fixing Energy meter box (PVC) with necessary holes.(sutiable for existing energy meter with kitkat 32 A fuse and neutral link) |
| 98 | Supply and Fixing kitkat 32 A fuse and neutral link. |
| 99 | Supply and laying of Electricity Service wire 2 run X 6 sqmm copper cable with necessary insulated support wire from Electric pole to Energy meter(LHA twin qtrs - (60+60) 120, NA-II Qtrs - 30 mtrs, NA -III qtrs - 35 mtrs, NA-I qtrs - 45 mtrs) Iincluding all accessories, like screws, clamps, bolt and nut etc.,) |
| 100 | Providing and fixing of 25 mm GI pipe Class C(\"U\"bend pipe) for to laying service wire from pole to energy meter (including all accessories like, GI nipple, GI bend, copper clamp, ss bolt and but, etc.,)(for Na qtrs 3 Nos, LHA qtrs - 2 Nos) |
| 101 | Supply and laying of 4core X 6 sqmm Copper armoured PVC insulated/PVC sheathed XLPEpower cable as required. (Power house to Pump house |
| 102 | Supply and laying of 3core X 6 sqmm Copper armoured PVC insulated/PVC sheathed XLPEpower cable as required. (Power house to IQ |
| 103 | Supply and laying of 2 core X 16 sqmm Copper armoured PVC insulated/PVC sheathed XLPEpower cable as required. (Genset room o/p to Power house) |
| 104 | Applying wall white putty and painting in wherever plastering work done in all quarters. |
| 105 | Labour charge for Dismantling of old wiring, fans, cables, switch board and electrical fittings etc., at NA Qtrs 3 No, LHA qtrs 2 Nos, IQ and power house and dismantling of Old panel Board etc., handed over to Station incharge. |
| 106 | Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, 25mm PVC bends, tees, 1,2,3,4 way junction boxes,Cutting plates, 12 mm Fan hooks, Fan rod for extension, wire strippers, steel spring, pvc junctions boxes, SS Clamp etc., Wall white putty and paints.(for Na qtrs 3 Nos, IQ - 1 No,LHA qtrs - 2 Nos, PH - 1No) |
| 107 | Making earth pit charges(additional) of Sl No. 2.055 for Lighthouse located at hill & rocky area diffcult to digging earth pit(heavy duty machinary and labour charges) (plate earthing) |
| 108 | Making earth pit charges(additional) of Sl No. 2.056 for Lighthouse located at hill & rocky area diffcult to digging earth pit(heavy duty machinary and labour charges) |
| 109 | Black stone cutting charges for concealed wiring and making hole 600 mm wall for cable entry As buildings are constructed by black stone. |
| 110 | Supply, Installation and testing of LT Distribution panel, Fabriated out of 16SWG CRCA Sheet not less than 2mm thick, powder coated, dust/vermin proof, compartmentalized with hinged doors, with one incomer and 3 outgoing with followingsingle front, fixed type indoor installation type, Power Control Cubical Panel-with double bus bar system and Epoxy based powder coating of Colour Siemens Gray.(Wall Mounted)100A,Kit-Kat Fuse Re-wirable type - 3 nos.200A, Neutral Link - 1 no.100A, 4Pole, MCCB - 1 no. Digital VAF(Multifuction) Meter along with necessary CT & PTR,Y,B Phase Indication Lamps (LED Type) 63A 2 Pole 2 Way Change over Switch63A 1 Pole 3 Way Phase Selector Switch25kA, 4Pole,320V AC SPD Surge Protector - 1 no. OUT-GOING FEEDERS:Single Pole 10AMCB - 3 Nos, 16A MCB -3 Nos 20A MCB - 3 nos.32A 4 pole MCB -1 No |
| 111 | Supply of 16 Sqmm, 4 core Pvc Ins Copper Flexible Cable(for internal loop wiring in power house) |
| 112 | Supply and Installation of Street light poles with LED fitting at Vengurla Point Lighthouse- ANNEXURE_III |
| 113 | Electrical Fittings /Cables/ |
| 114 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 115 | Double pole (6A) |
| 116 | Providing, laying and fixing 80mm dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required(for RCC road crossing) |
| 117 | Supply of Outdoor25Watt LED COB(chip on board)street light fitting (Diecast powdercoated enclosurewith structured LED arrays and IP65/66 protectionand) |
| 118 | Supply of Outdoor IP65 Wall Mounting Gate Light Luminaries, 20W LED with Big doom |
| 119 | Supply and laying of 3core X 2.5sqmm Copper armoured PVC insulated/PVC sheathed XLPEpower cable as required. |
| 120 | Supply of 2.5 Sqmm Cable gland |
| 121 | Supply and Installation 3\" Dia Class \"C\" GI pipe 4 meter Length (as per drawing) alongwith applying 1 coat primer and 2 coat aluminium paint. |
| 122 | Supply and Installation of 1\" threaded 45 degree bend pipe 1 meter length alongwith applying 1 coat primer and 2 coat aluminium paint. |
| 123 | Supply and Installation of 3\" to 1\" GI reducer alongwith applying 1 coat primer and 2 coat aluminium paint. |
| 124 | Supply and fixing of SMC Pole mounted Junction Box (200X140X95mm)with side hinged door, IP55 with necessary clamps/ Strip, SS screws/Nut and blot, etc., |
| 125 | Supplying and laying of 3 Core 1.5 Sqmm PVC Copper cable(from street light fitting to jn box) |
| 126 | Supply and fixing 11/2\" PVC HDPE flexible(Hard) pipe Thickness aprox 3mm hard pipe (To fixing foundation for laying cable from under ground to junction box) |
| 127 | Supply of 1 Phase street light timer |
| 128 | Supply of PVC enclosure for fixing street light timer |
| 129 | Making cable trench for laying cable direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Rocky area)(street light cable, pump house & IQ cable) |
| 130 | Electrician (Labour) Charges for wiring of streelights, and fitting luminaries, timer, etc., |
| 131 | Foundation and base work for Streetlights |
| 132 | Base of Streetlights: Earthwork Excavation(0.6 x 0.6 x 0.5m) for the foundation of steeetlight, 1:2:4 (1 cement : 2coarsesand:4gradedstoneaggregate20mmnominalsize)ConcreteWork(0.6x0.6x0.5m)forthe foundation with Post pipe placed in concrete inclusive of materials, Brick Work (0.45 x 0.45 x 0.45m)for post base and placing of pipes forcable entry, Plastering Work (4 x 0.45 x 0.45) +(0.45 x 0.45) for post base and Painting Work applying 1 coat White primer Paint and 2 coat Synthtic enamel Red Paint.(4 x 0.45 x 0.45)+(0.45x 0.45) |
| 133 | Labour charge for dismentaling of old street lights |
| 134 | Miscellaneous items for the purchase of SS bolt and nut, Screws etc., |
| 135 | Supply and Installation of ESE Lightning arrester at Vengurla Point Lighthouse Annexure - IV |
| 136 | Lightning arrester |
| 137 | Providing and fixing 25 mm X 3 mm copper strip on surface or in recess for connections etc. as required. (For Lightning arrester) |
| 138 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal / coke and salt as required.(For Lightning arrester) IS 2309 1969: Code of practice for the protection of building and allied structures against lightning.(Two earthing) |
| 139 | Supply of Early Streamer Emission (ESE) lightning conductor. Equipped with Stainless central pick up rod. Full electrical continuity between the tip and the earth point. Fully autonomous (no battery, no external power supply required) Collect energy through streamer emission controlled with detects the lightning and trigger a streamer (3,5KV and 20A). The ESE shall cover the area of 60 mtrs. Radius. Manufactured as per CPRI Requirements & as per Indian standard. |
| 140 | Supply of 6 mtr. single lengthelevation pole (Lightning arrester mast) made of GI “C” Class 40mm dia. with a M20 thread at the top to fix the ESE unit. Necessary provisions shall be provided for stay wire termination, fixing of insulated copper flat laying from the top(ESE unit) of the mast to bottom of the mast. The bottom of the mast shall be welded with 300 x 300 x 10mm GI plate and supported gazette plate with 4 nos. of 22mm hole suitable for making foundation bolt for fixing the mast. The stay wires shall be made of 6mm SS in the grade of 304 with suitable SS wire rope clamp which withstand salty atmosphere and wind speed of 150km/hr. |
| 141 | Providing and fixing of additional 6 feet Triangle GI support to the mast pipe with hand rail using40mm GI ‘C’ class pipe by using copper clamp with SS bolt and nut. |
| 142 | Supply of Lighning flash counter |
| 143 | Supply of 40mm insulator pipe for fixing ESE lightning arrester pipe with basement of mast pipe. |
| 144 | Supply ofTest link box(GI)(Test link point should be copper strip with brase bolt and nut) |
| 145 | Installation of ESE Lightning arrester, insulator pipe, lightning mast Pipe, flash counter, Test link, etc., |
| 146 | Making earth pit charges(additional) refer Sl No.4.013(for earthing) Lighthouse located at hill & rocky area diffcult to digging earth pit(heavy duty machinary and labour charges) (for plate earthing) |
| 147 | (refer Sl No 4.012) (Additional + risk charge) Laying of 25X3mm copper strip (For vertical run) at the out side of LH tower on surface of wall from Lighthouse tower top (lightning arrester)to LH bottomearth pit by clamping the tape at the distance of 2 feet using insulator, fisheres(wall plug), ss screws tools.(includingallaccessorieslike,Nylon rope, safety belt etc.,) |
| 148 | Miscellaneous items for the purchase of S.S screws,SS washer, bolt&nut, Ceramic Strip Insulator- 80 Nos, insulation tape, Insulation sleeve, Fisheres(wall plug) etc., |
AI Tender Summary
Tender Timeline
Sep 22, 2022
11:30 IST
Tender Published
Tender notice published.
CompletedOct 06, 2022
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 07, 2022
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender