}

General-Pwd Rest House Kothamangalam-Supply Installation Testing Commissioning Of Washing Machine, Fridge, Vacuum Cleaner, And Water Cooler And Maintenance To The Ei-General Electrical Work, kothamangalam-Kerala

Public Works Department-PWD has published General-Pwd Rest House Kothamangalam-Supply Installation Testing Commissioning Of Washing Machine, Fridge, Vacuum Cleaner, And Water Cooler And Maintenance To The Ei-General Electrical Work. Submission Date for this Tender is 29-09-2022. Housekeeping Equipments Tenders in kothamangalam Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

34055184
General-Pwd Rest House Kothamangalam-Supply Installation Testing Commissioning Of Washing Machine, Fridge, Vacuum Cleaner, And Water Cooler And Maintenance To The Ei-General Electrical Work
Open Tender
Indian
Kerala
kothamangalam
29-09-2022

Tender Details

General-Pwd Rest House Kothamangalam-Supply Installation Testing Commissioning Of Washing Machine, Fridge, Vacuum Cleaner, And Water Cooler And Maintenance To The Ei-General Electrical Work

Key Value

Document Fees
INR 660 /-
EMD
INR 7478.0 /-
Tender Value
Refer document

BOQ Items

Work Name:GENERAL-PWD Rest House Kothamangalam-SITC of washing machine,Fridge,vacuum cleaner, and water cooler and Maintenance to the EI-General Electrical Work
Sl. No. Item Description
1SITC of washing machine,Fridge,vacuum cleaner, and water cooler
2OD13431/2022-2023:SITC of BOSH 10 Kg Fully automatic Front Load with in built heater white ( 10 kg inverter fully automaticFront Load washing machine WGA254A0IN white in built heater
3OD13432/2022-2023:SITC of fobes wet and dry Vacuum cleaner
4OD13433/2022-2023:SITC of 80 litre Storage water cooler samsung make or equilvalent reputed make
5OD13434/2022-2023:SITC of Samsung 253 litre 3 star with inverter Double Door Refrigerator
690.6.10.1:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required20 mm
790.6.10.2:Supply and fixing of following sizes of light gauge PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required25 mm
81.17.11:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 2.5 sq. mm
91.17.20:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.2 x 4 sq. mm
101.17.22:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.4 x 4 sq. mm
11OD27980/2022-2023:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.1x10 sq. mm
121.27.2:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mmX75mm)
131.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm)
141.24.3:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch
151.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet
1690.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator
1790.10.3.32:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3 pin plug top with indicator
1890.10.3.33:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )25A 3pin Shuttered socket
192.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole
2090.16.1.1:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.00 mm copper conductor ( 14 SWG)
2190.16.5.1:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.2.00 mm (14 SWG)
22OD28187/2022-2023:Supply of superior quality copper tubular cable socket and making core termination of cables of the following sizes including crimping etc. as required. - 10 sq mm
23OD13438/2022-2023:Supply and providing the following sizes of bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required 12 x 3 mm brass bolt & nut
2490.2.1.4:Supply and wiring points according to IS 732-1989 using rigid PVC conduit of minimum size 20 mm with specials conforming to IS 9537 part III 1983 and with suitable size specials conforming to IS 3419-1988, fixing the conduit using metal saddles spacing not exceeding 50 cm or concealed suitably and with 1.00 sq mm FRLSPVC insulated stranded single core copper conductor cable 650V grade, including providingswitch boardmain and continuous earthing with No.14 SWG bare copper,required quantity of copper earth socket, brass bolt and nut crimping/ soldering etc complete with suitable size modular type metal switch boxes, modular type front plates (white) etc. up to and including 6A modular type SP switches and making good the surface of wall, colour washing etc. complete. All the terminations in the switch boards and DB"s shall be tinned and the wires shall be drawn and fixed along the periphery of the box using suitable ties, tie mounts etc as required. (RoHS compliant modular accessories).Single control ceiling fan point with 6 A, 3 plate ceiling rose & with socket size stepped electronic regulator. - Short point
2590.3.19.3:Supply conveyance, installation, testing and commissioning the light fittings of following types made from CRCA sheet 0.5mm thickness with all accessories andlamps directly on wall and giving connections with 16/0.20 mm 3 core PVC insulated and sheathed round copperconductor flex wire or extending the original wiring and giving connections as required1200 mm 1X20W LED Lamp with box type fixture
2690.3.20.3:Supply & installation of light fittings on TW round block Supply, conveyance installation testing and commissioning the light fittings of following types made of CRCA with 0.5mm thicknesscomplete with all accessories andlamps etc. directly on wall or ceiling with PVC round block neatly painted to suit the fitting and giving connection with required length of 16/0.20mm 3 core copper conductor flex wire conforming to relevant ISS and giving connections as required.1200 mm 1X20W LED Lamp with box type fixture
2790.4.5.4:Supply, Installation, testing and commissioning of ceiling fan of following sizes including wiring the down rods of standard length (up to 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 1200mm sweep - ceiling fan complete with service value minimum 4.0(cub meter/minute/Watt), Air delivery minimum 210(cubic meter/minute), Copper winding suitable for 230V/240V single phase AC supply
28OD13435/2022-2023:Supply and fixing 7/9 W LED power rated lamps in the existing fittings as required.
29OD20375/2022-2023:supply and fixing 3 plate ceiling rose
30OD28214/2022-2023:Supply and Renewal of Ceiling fan capacitor in the place of damaged ones as required.
312.10.4:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Triple pole
322.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps
33OD27926/2022-2023:Supplying and fixing 40 amps to 63 amps, 10KA rating, 240/415 volts, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole
3490.14.10.4:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 25/35 kA (Ics=100%Icu), 4 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
3590.12.2.30:Supply and laying of one number additional PVC insulated and PVC sheathed armoured aluminium powercable of 1.1KV grade of the following sizes in ground in the same trench in one tier horizontal formation including wideningthe trench by 20 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil)3.5 core 70 sq mm
36OD28012/2022-2023:Supply & fixing 6A to 125A DIN type HRC fuse links of size 00
37OD28013/2022-2023:Supply & fixing 100 A, 415 V, DIN type fuse base
38OD28014/2022-2023:Supply & fixing 100A, 415 V, 2 way neutral link mounted on DMC/ SMC base.
39OD28225/2022-2023:Charges for altering the existing circuit from the one DB to another
40OD28226/2022-2023:Dismantling the existing wiring, conveying the same to the section office and kept in section store including loading and unloading charges in both ends.
41OD28227/2022-2023:Cleaning the existing EI complete, washing the shade, bulb, tube etc., attending petty repairs to connections and make the EI on good working condition.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail