Jawaharlal Institute Of Post Graduate Medical Education And Research-JIPMER has published Rate Contract For Supply Of Consumables And Non Consumables Rate Contract For Supply Of Consumables And Non Consumables For The Department Of Medicine , Consumables Note: For All Items Sample Should Be Submitted. Without Sample Quotation Will Be Rejecte. Submission Date for this Tender is 19-10-2022. Diaper Tenders in puducherry Puducherry. Bidders can get complete Tender details and download the document.
Sl. No. | Item Description |
1 | CONSUMABLES Note: For all Items sample should be submitted. Without sample quotation will be rejected |
2 | Adult diaper, latex free, hydrophilic non-woven- 50”-70” |
3 | Adult underpads |
4 | Alpha Bed |
5 | Ambu Bag (Adult)-Autoclavable (latex free) Silicone Resuscitators compressible self filling body with volumemore than 1500 ml, non-rebreathing valve, air intake valce, patient connector ( 15 mm inside -22 mm outside) appropriate masks size 3 & 4 |
6 | Ammonium Sulphate(500 gm /pack) |
7 | Arterial cannulae 20G with flow switch; Length less than 5 cm |
8 | Arterial cannulae with seldinger technique - 3 Fr alongwith 19 / 20 G puncture needle between 3 - 6 cms and accompanying guidewire 20 - 30 cms.Intra-arterial catheter set with introducer needle, straight guide wire, transparent and radio-opaque poly-ethylene catheter with winged hub |
9 | Auto-venting 1ml arterial blood sampling syringes with dry sprayed balanced heparin formulations (lithium heparin) with 22-25G needle with needle stopper, preferably with needle safety sheath and filter cap |
10 | Bain Circuit (Adult) - 22mm Corrugated Plastic Hose X 1.6 mtrs long, 22mm/22mm Male/Female Circuit Adaptors X 2, PVC Tubing X 3mtrs., 22mm Heidbrink Expiratory Valve, 15mm/22mm Angle Mount, 2Ltr. Breathing Bag, 23mm Male Plug in Mount, 23mm/23mm Female/Female Circuit Adaptor provided with plastic bag. |
11 | Bone Marrow biopsy needle (Jamshidi type needle; should have plastice handle; integral stylet lock to prevent obstruction by debris; 8Gfor adult. |
12 | Catheter Mount - 175 mm, Expandable with Luer sampling port |
13 | Chest tubes (size12,14) |
14 | Closed Ventilation suction catheter system size 14Fr & 12 Fr for ET Tube suction |
15 | Cover Slip 22 mm X 22 mm |
16 | CVP Catheter (Triple lumen) - 7 Fr., 12-15 cms,. full set guide with spring guide wire -seldinger type, introducer needle(18 gauge), syringe, catheter clamp, dilator |
17 | Dial Flow (I.V. infusion dial regulator) Flow rates from 20 to 250 ml / hr; Stable flow rates upto 72 hrs; Reliable and accurate flow control; Dial with ridges for easy gripping and adjustment |
18 | Disposable ESR tube |
19 | Disposable pressure Transducer-Compatible to GE/L&T monitors |
20 | Double Lumen Dialysis Curved extension catheter Kit with following parameters (a)Two lumens of Double-D design (b) Laser Cut Side slots to avoid positional occlusion (c)Clear. Silicon Extensions(d) Size 11.5 Fr x (12-14 cm) (e) 2 dilators in a pack |
21 | ECG Bulb Electrode Adult size (Pack of Six) |
22 | ECG Clip Clamp, Set of 4, Adult Size |
23 | ECG Gel (250 ml) |
24 | ECG Paper BioCare - Z type (210mm x 140 mm, 100 sheets) |
25 | ECG Paper Mortara ELI 230, 210 mm x 20 mtrs |
26 | ECG Paper Mortara ELI 250 (210mmx300mm, 200 sheets) |
27 | ECGGel Electrode |
28 | ECHO /Ultrasound gel (250 ml) |
29 | Emergency percutaneous cricothyrotomy set with seldinger technique |
30 | Endotracheal tube cuff pressure monitor |
31 | ET Tube (PVC) Cuffed - Murfy eyes6.5,Reference marks above cuff to aid in proper placement of tracheal tube tip, Murphy eye; Radiopaque line |
32 | ET Tube (PVC) Cuffed - Murfy eyes7.0,Reference marks above cuff to aid in proper placement of tracheal tube tip, Murphy eye; Radiopaque line |
33 | ET Tube (PVC) Cuffed - Murfy eyes7.5,Reference marks above cuff to aid in proper placement of tracheal tube tip, Murphy eye; Radiopaque line |
34 | ET Tube (PVC) Cuffed - Murfy eyes8,Reference marks above cuff to aid in proper placement of tracheal tube tip, Murphy eye; Radiopaque line |
35 | ET Tube (PVC) Cuffed - Murfy eyes8.5,Reference marks above cuff to aid in proper placement of tracheal tube tip, Murphy eye; Radiopaque line |
36 | Femoral Arterial catheter - 20G and 22 G with Seldinger Arterial Catheterisation set and guide wire. |
37 | Glacial Acetic Acid 500ml |
38 | Guedul"s Airways (PVC) size 3 |
39 | Guedul"s Airways (PVC) size 4 |
40 | Guedul"s Airways (PVC) Size 5 |
41 | Guedul"s Airways (PVC) size 6 |
42 | Gum elastic bougie (to aid difficult intubation): Reusable; 15 F sizes of at least 70 cm length |
43 | High Pressure monitoring lines (M-F) - 200 cm |
44 | HME Filters:Made of high quality substance for maximal heat and moisture exchange. |
45 | Humidifier base with chamber compartible with Maquet Servo Ventilator |
46 | Laryngoscope (Adult) with blades sizes3, 4 & 5 (machintosh mat finish) with long thread LED bulb and life more than 40,000 hrs, glare free, design compatible with AA batteries, 5 years warranty with MAC size 3, 4 & 5 Blades. |
47 | Laryngoscope Bulbs LED (compatible with machintosh mat finish) |
48 | Legionella Urinary (Antigen Card) |
49 | Liquid Ammonia 500ml |
50 | Microscope Glass Slide 25 × 75mm |
51 | Nasal Prongs - Soft, non-toxic PVC; Twin, over-the-ear style, soft, flexible prongs with adjustable slide and collapse resistant lumen; Soft funnel-shaped universal connector for easy connection to oxygen sources |
52 | NIBP cable and cuff compatible with CARESCAPE MONITOR B450- adult size |
53 | NIBP cable and cuff compatible with CARESCAPE MONITOR B450- large adult size |
54 | NIBP cable and cuff compatible with CARESCAPE MONITOR B450-small adult size |
55 | NIV face mask- Medium - Non Vented |
56 | NIV face mask- Medium - Vented |
57 | O-toluidine Powder 500gm/pack |
58 | Oxygen mask with Tubing (without Nebulizer) - Adult |
59 | Oxygen mask with Tubing and Venturi Nebulizer - Adult |
60 | Oxygen mask with Venturi adaptors (six in number, colour coded for different Fio2)+B80 |
61 | Pacing Catheter - 7F |
62 | Pericardiocentesis catheter (Single Lumen CVP catheter) Adult |
63 | Polypropylene Micro Tips 100 - 1000 ul |
64 | Polypropylene Microtips 10 - 100 uL |
65 | Portable Ultrasonic Nebulizer : compact nebulizer, for administration of aerosolied medication & sputum induction, operating on ultrasonic nebulization technology should run on 220v/50hz power supply. Should have adjustable air flow & nebulization rates. Nebulization rate upto 3ml/min & particle size 4um." |
66 | Pressure Bags for invasive blood pressure monitoring - 1 ltrs |
67 | Pressure Bags for invasive blood pressure monitoring - 1/2 ltrs |
68 | NRBM with re-breathing bags |
69 | Saturation probe and cable compatible with CARESCAPE MONITOR B450 |
70 | Spinal needle (22 G ) sterile, disposable for single use |
71 | Spinal needle (24 G) sterile, disposable for single use |
72 | Sterile suction catheter with mucous extractor/trap; 25 ml trap; 14 ch, 30-35 cm suction catheter with terminal eye only; Soft PVC, sterile, straight peel pouch with sponge filter and spare cap, screw fit |
73 | Sterile suction catheter with side opening at proximal end for thumb occlusion Size 14FG; Length approx 50 cm |
74 | Sterile suction catheter with side opening at proximal end for thumb occlusion Size 16FG; Length approx 50 cm |
75 | Stillet with PVC insulation, malleable with metal core and soft retracted metal tip - Adult |
76 | Temporary cardiac pacing leads (transvenous VVI pacing; compatible with biotronic pacemakers available at the user department) |
77 | Test tube (Plastic) - 12 X 100 mm |
78 | Three way stop cock. Stop cock should have polycarbonate body with male Luer lock nut and polyethylene luer caps. Flow rate: Straight: 650-700 ml / min; Side port: 450 - 500 ml / min |
79 | Three way stop cock with extension 10 cms, Stop cock should have polycarbonate body with male Luer lock nut and polyethylene luer caps. Flow rate: Straight: 650-700 ml / min; Side port: 450 - 500 ml / min (Low pressure) &Through proper channel |
80 | Three way stop cock with extension25 cms,. Stop cock should have polycarbonate body with male Luer lock nut and polyethylene luer caps. Flow rate: Straight: 650-700 ml / min; Side port: 450 - 500 ml / min (Low pressure) &Through proper channel |
81 | T-piece connector (with corrugated side tube and oxygen nipple) |
82 | Tracheal Mask |
83 | Tracheostomy Tubes - 7.0 mm |
84 | Tracheostomy Tubes - 7.5 mm |
85 | Tracheostomy Tubes - 8.0 mm |
86 | Tracheostomy Tubes - 8.5mm |
87 | Transparent catheter site cloth-reinforced dressing of polyurethane material impervious to bacteria but permeable to water vapor maintaining transparency, selfadhesive, three-piece design with split edge in the large piece (8.5 cm × 11.5 cm) to surround the catheter and ensure proper securing of the central line catheter, preferred with CE/FDA approval |
88 | Transparent catheter site cloth-reinforced dressing of polyurethane material impervious to bacteria but permeable to water vapor maintaining transparency, selfadhesive, three-piece design with split edge in the large piece (8.5 cm × 11.5 cm) to surround the catheter and ensure proper securing of the central line catheter, preferred with CE/FDA approval. With Chlorhexidine gluconate gel layer |
89 | Urine dipstick for Glucose and Protein |
90 | Urine dipstick for Ketones |
91 | Pneumococcal antigen, urinary |
92 | Ventilator Circuits with Water chamber - Compatible with Fisher and Paykel Humidifier Base |
93 | Ventilator Circuit-single patient use, disposable with water traps double limb circuit |
94 | Ventilator Circuit-single patient use, disposable with water traps single limb circuit |
95 | Binocular Microscope (Without D.G) SPECIFICATION Coarse & Fine focus 5x, 10x, 40x, 100x magnification Adjustable eye piece Moveable Abbe condenser 6 – position disk diaphragm Built-in illumination with halogen bulb with 2 spare bulbs Warranty: 3 years from the date of installation |
96 | Centrifuge SPECIFICATION Design, Bench top Max. RPM,4500/6000 Max. RCF (g)/3330 RPM setting accuracy:+-5% Type of lid lock: Electronic with automatic opening/manual lock enable for start up. Type of rotor:Swing out rotor /angle rotor Number of tubes / rotor : 24 Type of tube to be used:Polypropylene & Glass Rotor imbalance detection & Auto stop if required : Yes Max. Time set point : 60 min Number of steps of RPM variation: 7 RPM & Time control : Digital Display type : LED/LCD Power supply : 180-250 volts Length of power cord : 2 metres Warranty period of equipment and rotor: 3 years |
97 | Digital pH meter with 3 standard buffers SPECIFICATION Should have Working range from 0 to 14. Should have Resolution 0.1 or 0.01 pH Should have Temperature compensation zero to 100 degree C Should have Rs. 232C output and supply Data connector cable. Should have Automatic calibration facility. Should have 3 state calibration. Should have digital display with 0.001 pH unit readability. Should supply Tri-combination pH/ATC electrode. Should supply Electrode + Standard buffer solution (pH 4.0,7.0,10.0)) Should be provided with an electrode holder / arm with smooth movement Warranty – 3 year. |
98 | Laboratory Timer SPECIFICATION Digital display Beeper alarm Magnetic stand Countdown display. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail