Provision Of Otm For 140 Or In Design & Build Basis At Gulmarg - Lumpsum / Other Pre-Priced Provisional Schedules Of Works 3 Lump Sum Price Worked Out By The Contractor For Building Works As Listed In Schedule A Part-I Section-Ii Brought Forward Fro, Baramulla-Jammu And Kashmir

Military Engineer Services-MES has published Provision Of Otm For 140 Or In Design & Build Basis At Gulmarg - Lumpsum / Other Pre-Priced Provisional Schedules Of Works 3 Lump Sum Price Worked Out By The Contractor For Building Works As Listed In Schedule A Part-I Section-Ii Brought Forward Fro. Submission Date for this Tender is 05-12-2022. Tanks and Cylinders Tenders in Baramulla Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34042849
Corrigendum : Provision Of Otm For 140 Or In Design & Build Basis At Gulmarg - Lumpsum / Other Pre-Priced Provisional Schedules Of Works 3 Lump Sum Price Worked Out By The Contractor For Building Works As Listed In Schedule A Part-I Section-Ii Brought Forward Fro
Open Tender
Indian
Jammu And Kashmir
Baramulla
05-12-2022

Tender Details

Provision Of Otm For 140 Or In Design & Build Basis At Gulmarg - Lumpsum / Other Pre-Priced Provisional Schedules Of Works 3 Lump Sum Price Worked Out By The Contractor For Building Works As Listed In Schedule A Part-I Section-Ii Brought Forward From Serial Page No. 38 4 Lump Sum Price Worked Out By The Contractor For Internal Electrification Works As Listed In Schedule A Part-Ii Brought Forward From Serial Page No. 41 5 Lump Sum Price Worked Out By The Contractor For Internal Water Supply Works As Listed In Schedule A Part-Iii Brought Forward From Serial Page No. 45 6 Lump Sum Price Worked Out By The Contractor For Sewage Disposal Works Listed In Schedule A Part-Iv Brought Forward From Serial Page No. 47 7 Lump Sum Price Worked Out By The Contractor For Road, Path And Culvertworksas Listed In Schedule A Part-V Brought Forward From Serial Page No. 50 8 Lump Sum Price Worked Out By The Contractor For Area Drainage Works As Listed In Schedule A Part-Vi Brought Forward From Serial Page No. 52 9 Lump Sum Price Worked Out By The Contractor For Protective / Retaining Wall Worksas Listed In Schedule A Part-Vii Brought Forward From Serial Page No. 54 10 Lump Sum Price Worked Out By The Contractor For External Water Supply Works As Listed In Schedule A Part-Viii Brought Forward From Serial Page No. 56 11 Lump Sum Price Worked Out By The Contractor For Site Clearance & Earthworks As Listed In Schedule A Part-Ix Brought Forward From Serial Page No. 58 12 Lump Sum Price Worked Out By The Contractor For External Electrification Works As Listed In Schedule A Part-X Brought Forward From Serial Page No. 61 13 Buildingworks Based On Design & Build ( Schedule A Part I Section I ) 14 Design, Supply And Erect, Peb Buildings With Wall Of Lgsf Based On Rapid Constructiontechnology For Construction Of Single Living Accn For 140 Ors ( Double Storey ) Complete All As Specified And Shown On Drawings. 15 Internal Electrification Works ( Schedule A Part-Xi ) 16 Material And Labour For Point Wiring Complete Withpvc Insulated Unsheathed 1100 Volt Grade Frls Cable With Multi Stranded Copper Conductor Of Size 1.5 Sq Mm ( Nominal Area ) Drawn Through And Including Pvc Conduit ( Medium Duty ) Of Suitable Size ( As Per Conductor Run ) With All Fittings And Accessories Concealed In Wall And Ceiling Portion Inculding Concealed Sunk In Pressed Steel Terminal Bozes Of Not Less Than 2Mm Thick Required Size Factory Made And Painted With Synthetic Enamel Paint Black Paint With Including Top Cover 3Mm Thick Plastic Laminated Sheet ( Make : Hylum ) Of Required Colour Fixed With Brass Screws And Cup Washers With And Including 1.5 Sqmm Frls Multi Stranded Copper Conductor As Continuous Earth Wire Drawn In Same Concealed Conduit, Connected To Main Earth And Earth Dolly Including Cutting Chases And Making Good As Per Existing Specification For One Light / Fan / Exhaust Fan Point Controlled By One Way Switch 5Amp Complete All As Specified And Directed. 17 Material And Labour For Point Wiring Complete Withpvc Insulated Unsheathed 1100 Volt Grade Frls Cable With Multi Stranded Copper Conductor Of Size 1.5 Sq Mm ( Nominal Area ) Drawn Through And Including Pvc Conduit ( Medium Duty ) Of Suitable Size ( As Per Conductor Run ) With All Fittings And Accessories Concealed In Wall And Ceiling Portion Inculding Concealed Sunk In Pressed Steel Terminal Bozes Of Not Less Than 2Mm Thick Required Size Factory Made And Painted With Synthetic Enamel Paint Black Paint With Including Top Cover 3Mm Thick Plastic Laminated Sheet ( Make : Hylum ) Of Required Colour Fixed With Brass Screws And Cup Washers With And Including 1.5 Sqmm Frls Multi Stranded Copper Conductor As Continuous Earth Wire Drawn In Same Concealed Conduit, Connected To Main Earth And Earth Dolly Including Cutting Chases And Making Good As Per Existing Specification For One Light Point Controlled By Two Way Switch 5Amp Complete All As Specified And Directed. 18 Material And Labour For Point Wiring Complete Withpvc Insulated Unsheathed 1100 Volt Grade Frls Cable With Multi Stranded Copper Conductor Of Size 1.5 Sq Mm ( Nominal Area ) Drawn Through And Including Pvc Conduit ( Medium Duty ) Of Suitable Size ( As Per Conductor Run ) With All Fittings And Accessories Concealed In Wall And Ceiling Portion Inculding Concealed Sunk In Pressed Steel Terminal Bozes Of Not Less Than 2Mm Thick Required Size Factory Made And Painted With Synthetic Enamel Paint Black Paint With Including Top Cover 3Mm Thick Plastic Laminated Sheet ( Make : Hylum ) Of Required Colour Fixed With Brass Screws And Cup Washers With And Including 1.5 Sqmm Frls Multi Stranded Copper Conductor As Continuous Earth Wire Drawn In Same Concealed Conduit, Connected To Main Earth And Earth Dolly Including Cutting Chases And Making Good As Per Existing Specification For One Three Pin 5Amp Switch Socket Outlet Point On Independent Board Complete All As Specified And Directed. 19 Material And Labour For Point Wiring Complete Withpvc Insulated Unsheathed 1100 Volt Grade Frls Cable With Multi Stranded Copper Conductor Of Size 2.5 Sq Mm ( Nominal Area ) Drawn Through And Including Pvc Conduit ( Medium Duty ) Of Suitable Size ( As Per Conductor Run ) With All Fittings And Accessories Concealed In Wall And Ceiling Portion Inculding Concealed Sunk In Pressed Steel Terminal Bozes Of Not Less Than 2Mm Thick Required Size Factory Made And Painted With Synthetic Enamel Paint Black Paint With Including Top Cover 3Mm Thick Plastic Laminated Sheet ( Make : Hylum ) Of Required Colour Fixed With Brass Screws And Cup Washers With And Including 1.5 Sqmm Frls Multi Stranded Copper Conductor As Continuous Earth Wire Drawn In Same Concealed Conduit, Connected To Main Earth And Earth Dolly Including Cutting Chases And Making Good As Per Existing Specification For One Six Pin Socket Outlet Two In One 6 / 16 Amp Point On Independent Board Complete All As Specified And Directed. 20 Supply And Fixing Tv Socket Completeall As Specified And Directed. 21 Supply And Fixing Telephone Socket Rj-11 Completeall As Specified And Directed. 22 Material And Labour For Sub Main Wiring ( Concealed ) Complete With Four Single Core 6.00 Sqmm Frls Pvc Insulated Unsheathed Stranded Copper Conductor Cable Drawn Through In And Including 20 Mm Dia Rigid Non-Metallic Pvc Conduit And Conduit Accessories Including Two Single Run Of 6.00 Sqmm Frls Pvc Insulated Unsheated Stranded Copper Earth Cable Connected To Common Earth Dolly Complete And Including Cutting Chasing In Walls For Concealed Wiring Using Machine Cutting And Making Good The Disturbed Surface All As Specified And Directed.Note:- Six Runs Of 6 Sqmm Cable And One Run Of Pvc Conduit Shall Be Measured As One Unit. 23 Material And Labour For Sub Main Wiring ( Concealed ) Complete With Two Single Core 2.50 Sqmm Frls Pvc Insulated Unsheathed Stranded Copper Conductor Cable Drawn Through In And Including 20 Mm Dia Rigid Non-Metallic Pvc Conduit And Conduit Accessories Including One Single Run Of 2.50 Sqmm Frls Pvc Insulated Unsheated Stranded Copper Earth Cable Connected To Common Earth Dolly Complete And Including Cutting Chasing In Walls For Concealed Wiring Using Machine Cutting And Making Good The Disturbed Surface All As Specified And Directed.Note:- Three Runs Of 2.50 Sqmm Cable And One Run Of Pvc Conduit Shall Be Measured As One Unit. 24 Material And Labour For Sub Main Wiring ( Concealed ) Complete With Two Single Core 4.00 Sqmm Frls Pvc Insulated Unsheathed Stranded Copper Conductor Cable Drawn Through In And Including 20 Mm Dia Rigid Non-Metallic Pvc Conduit And Conduit Accessories Including One Single Run Of 4.00 Sqmm Frls Pvc Insulated Unsheated Stranded Copper Earth Cable Connected To Common Earth Dolly Complete And Including Cutting Chasing In Walls For Concealed Wiring Using Machine Cutting And Making Good The Disturbed Surface All As Specified And Directed.Note:- Three Runs Of 4.00 Sqmm Cable And One Run Of Pvc Conduit Shall Be Measured As One Unit. 25 Material And Labour For Sub Main Wiring ( Concealed ) Complete With Two Single Core 6.00 Sqmm Frls Pvc Insulated Unsheathed Stranded Copper Conductor Cable Drawn Through In And Including 20 Mm Dia Rigid Non-Metallic Pvc Conduit And Conduit Accessories Including Two Single Run Of 6.00 Sqmm Frls Pvc Insulated Unsheated Stranded Copper Earth Cable Connected To Common Earth Dolly Complete And Including Cutting Chasing In Walls For Concealed Wiring Using Machine Cutting And Making Good The Disturbed Surface All As Specified And Directed.Note:- Three Runs Of 6 Sqmm Cable And One Run Of Pvc Conduit Shall Be Measured As One Unit. 26 Supply And Fixing Ceiling Fans Complete With Blades, Down Rods With Accessories, 230 V, 1200 Mm Sweep, Minimum Air Delivery 210 Cfm With Service Value 6.00 Bee, Five Star Rated With Brushless Direct Current Motor ( Bldc ) And All Accessories And Including Connecting Up With Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And Directed. 27 Supply And Fixingexhaust Fan Made Of Sturdy Engineering Plastic Complete With Louvers Shutter Including Mounting Frame, Voltage 230V, 50 Hz, 1200 Rpm, 36 Watt, Light Duty, Copper Winding Of Sweep 250Mm And All Accessories And Including Connecting Up With 1.50 Sqmm Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And Directed. 28 Supply And Fixingexhaust Fan Made Of Sturdy Engineering Plastic Complete With Louvers Shutter Including Mounting Frame, Voltage 230V, 50 Hz, 1350 Rpm, Light Duty, Copper Winding Of Sweep 300Mm And All Accessories And Including Connecting Up With 2.5 Sqmm Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And Directed. 29 Supply And Fixingexhaust Fan Made Of Sturdy Engineering Plastic Complete With Louvers Shutter Including Mounting Frame, Voltage 230V, 50 Hz, 1400 Rpm, Light Duty, Copper Winding Of Sweep 450Mm And All Accessories And Including Connecting Up With 2.5 Sqmm Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And Directed. 30 M&L For Earthing Complete With Galvinised Steel Earthplate Electrode 60 Cm X 60Cm X 6Mm Thickburied Directly In Ground ( Earth Pit Notless Than2.25 Mtr Deep Belownormal Groundlevel ) With Top Edgeof Platenot Less Than1.5 Mtr Belownormal Ground Level , Connectingto Galvanised Iron Wire 4Mm Dia, Protected By Galvanised Iron Light Grade Pipe 15Mm Dia And Galvanised Iron Water Pipe Medium Grade 20Mm Dia Upto 7.5 Mtr Including Provnof Concretepit Inpcc ( 1:4:8 ) Type D-2 Using 40 Mm Graded Stone Aggregates, Coping Shall Be Pcc 1:3:6 Type C1 Using 20 Mm Graded Stone Aggregate, Top Cover 50Mm Thick Of Rcc 1:2:4 Type B1 Using 20Mm Graded Stone Aggregate Reinforced With 8Mm Dia Tmt Bars @80Mm C / C Both Ways With Angle Iron Frame, Pit Shall Be Given 15Mm Thick Plaster In Cm 1:4 , Funnel With Wire Gauge ( 0.68Mm ) And Charcoal Dust And Common Salt All As In Shown In Electrical Plate No-03 Of Mes Ssr Pt-I And Specified And Including All Excavation And Earth Work And Connecting The Earthing Complete All As Specified And Directednote: The Unit Quoted Rate Of Earthing Shall Be Deemed To Included Cost Of 7.5 M Long Gi Earth Wire 4Mm Dia And Protection Pipe Gi 15 Mm Dia Light Grade, Gi 20Mm Dia Medium Grade Watering Pipe. Any Variation In Length Shall Be Adjusted Through Deviation Order. 31 Supply And Fixing Energy Efficient Led Tube Light Fitting 1 X 20 Watt, Luminaire Suitable For Surface / Pendant Mounting, With White Reflector Cover Fitted To The Body, Single Tube Mounting Rail Type, Connector Blcok Complete Prewired, Incluidng One Tube Rod Of 20 Watt, Connecting To Ceiling Rose With Suitable Copper Conductor Flexible Cable Complete All As Specified And Directed 32 Supply And Fixing Led Building Security Light With Pressure Die Cast Aluminum Housing With Polycarbonate Cover, Finless Design, Dedicated Peanut Optics, > 100 Lumen / W System Efficiency, Minimum 2500 System Lumens, 45W System Wattage ( Including Driver ) , Color Temperature > 5700K, Cri>80, Ip65 Protection, Ik07 Ratingincluding Suitable Size Of 1.5 Meter Long Bend 25Mm Dia Gi Pipe ( Light Grade, Bend At 120° ) With 40X 6Mm Fi Clamps And Fixing Accessories ( Nuts, Bolts And Washers ) Etc.The Potted Electronic Driver With Thd<10%, Pf>0.95, Led Fitting Is Complete All As Per Oem Specified And Directed. Led Driver And Housing Is Of Same Make As Of Light Fitting. All Type Of Testing For Photometry, Electrical And Electronic Parameters Is Done In Babi Approved Lab Complete All As Specified And Directed. Note: The Unit Quoted Rate Include The Cost Of Painting With Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer Over Ms Work. 33 Supply And Fixing Led Lamp 5 Watt Energy Efficient, 220 Volt, 50 Hz B22 Cap, Cool Day Light Complete All As Specified And Directed. 34 Supply And Fixing Warm White, Wall Mounted Led 11 Watt, Mirror Light ( Indoor ) Complete All As Specified And Directed 35 Supply And Laying Independent Pvc Conduit Pipe Confirming To Is: 9537 Part-Iii 1983, Medium Class, Outer Dia 25Mm Including Cuttings Chases On Wall And Making Goodfor Tv And Telephone Point Complete All As Specified And Directed. 36 Supply And Drawn In Conduit Telecom Pvc Insulated Cable For Indoor Applicances Confirming To Tec Specifications G / W / Ir06 / 02, 2 Pair Unarmoured, 0.5 Atc Complete All As Specified And Directed. 37 Supply And Drawn In Conduit Catv Coaxial Cable, ( Electrolytic Grade Solid Annelaed Coper Conductor, Jelly Field, Aluminimum Foiled And Aluminium Wire Braided ) 75 Ohms, Rg 11 Foam Signal Losses Db / 100Yds At 100 Mhz Complete All As Specified And Directed. 38 Supply And Fixing Factory Made Concealed Sunk-In Pressed Steel Terminal Boxes Of Size 75X75x60mm, Thickness Of Sheet Not Less Than 2Mm, Painted With Two Coats Of Synthetic Enamel Paint ( Black ) Over A Coat Of Primer With And Including Top Cover 3Mm Thick Plastic Laminated Sheet Of Required Colour Fixed With Brass Screws And Cup Washers Incluidng Cutting Chases For Tv And Telephone Socket Mounting And Making Good The Disturbed Surfaces Complete All As Specified And Directed. 39 Supply And Fixing Verticle Distribution Board Multiphase Outgoing For Mounting Mccb As Incomer Of Rating 100 Amp, Double Door, 4 Way, 415 Volt, 50 Hz, With Fixing Arrangement On Ms Frame Complete All As Specified And Directed. 40 Supply And Fixing Mccb Suitable For Verticle Distribution Board Of Make Hpl, Thermal Setting Fixed Type, Breaking Capacity 25Ka, 4 Pole, 100 Amp Complete All As Specified And Directed. 41 Supply And Fixing Mcb Sp 240 Volt, 50Hz , 10 Ka, C Series Of Rating06 To 32 Amp Confirming To Is / Iec-60898-1 & Is / Iec-60947-2 Completeall As Specified And Directed. 42 Supply And Fixing Mcb Sp 240 Volt, 50Hz , 10 Ka, C Series Of Rating63 Amp Confirming To Is / Iec-60898-1 & Is / Iec-60947-2 Completeall As Specified And Directed. 43 Supply And Fixing Mcb Spn 240 Volt, 50Hz , 10 Ka, C Series Of Rating6 To 32 Amp Confirming To Is / Iec-60898-1 & Is / Iec-60947-2 Completeall As Specified And Directed. 44 Supply And Fixing Mcb Spn 240 Volt, 50Hz , 10 Ka, C Series Of Rating40 To 63 Amp Confirming To Is / Iec-60898-1 & Is / Iec-60947-2 Completeall As Specified And Directed. 45 Supply And Fixing Mcb Tpn 415 Volt, 50Hz , 10 Ka, C Series Of Rating63 Amp Confirming To Is / Iec-60898-1 & Is / Iec-60947-2 Completeall As Specified And Directed. 46 Internal Water Supply Works ( Schedule A Part-Xii ) 47 Supply And Fixingtwo Way Bib Taps 15 Mm Bore, Cast Copper Alloy With Crutch Or Butterfly Handle, Screwed Down, Screwed For Iron Pipe Or For Brass Ferrule Fancy Type Chromium Plated Complete All As Specified And Directed. 48 Supplying And Fixingangle Valve Cast Copper Alloy, Chromium Plated, Screwed Down, High Pressure With Crutch Or Butterfly Handle, Screwed Both Ends For 15Mm Bore Iron Pipe Or For Unions And Fixed Complete All As Specified And Directed. 49 Supplying And Fixing 15 Mm Bore Health Faucet Of Approved Quality Chromium Plated With Flexible Pipe 1.50 Mtr Long And Making Connection Complete All As Specified And Directed. 50 Supplying And Fixing 15 Mm Borebrass Cp Whb Mixerfor Mixing Hot & Cold Water Screwed Down For Iron Pipe And Fixed Complete All As Specified And Directed. 51 External Water Supply Works ( Schedule A Part-Xiii ) 52 Material And Labour For Construction Of Valve Pit Of Size 60Cmx60cmx60cm ( Internal Dimensions ) By Excavation And Earth Work In Any Type Of Soil, Removal, Disposal Of Surplus Spoil To A Distance Not Exceeding 50M And Depositing Where Directed, Pcc ( 1:4:8 ) Type D-2 ( Using 40Mm Graded Crushedaggregate ) In Foundation, Brick Masonary In Cement Mortar ( 1:6 ) Using Old Size Sub Class B Bricks, Rendering 15Mm Thick In Cement Mortar ( 1:4 ) Internally, Neeru Finished Externally As The Work Proceeds In The Same Mortar, Coping In 1:2:4 ( Using 20Mm Graded Stone Aggregate ) , Angle Iron Frame ( 40X40x6mm ) , Ms Sheet Cover 3.15 Mm Thick With Sleeve Piece, Frame Work, Butt Hinge 125Mm Size With Handle 100Mm Of Ms Bar And Locking Arrangement, Paintingall The Exposed Ms Work With Two Coats Of Synthetic Enamel Paint Of The Tint As Approved By The Ge Over A Coat Of Red Oxide Primer And Painting All The Ms Embedded In Pcc With Two Coats Of Black Bituminous Paint Including Excavation And Earth Work, Internal And Three Coats Of White Wash On Exposed Plastered / Concrete Surfaces Complete All As Specified And Shown On Drawings. 53 Cutting Into Existing Gi Water Main 80Mm Dia In Position For Inserting New Tee / Specials For Branch Connection Of 50Mm Size Including Gi Tee 80X80x50mm Complete All As Specified And Directed. 54 External Electric Supply Works ( Schedule A Part-Xiv ) 55 Supply And Errection Of Steel Tubular Swaged Poles Complete With Cast Iron Base Plate, Finial Taper Plug, Bolts, Nuts And Screws As Specified Type 410 Sp-22 ( 8.5 Metres Long ) Including Two Coat Of Black Bituminous Paint Internally Throughout And Externally Upto Embeded Portion And Applying Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer With Black N White Strip Of 30 Cm Each Upto 1.5 Mtr Height And Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer Externally On Remaining Exposed Surface After Preparation Of Surface And Errection In Position, Complete All As Specified And Directed.Note :- Excavation And Earth Work, Pcc For Foundation And Coping Channels , Clamps Nuts, Bolts To Be Measured And Paid Separately. 56 Supply, Installation, Testing And Commissioning Outdoor Type, Plinth Mounted Step Down Transformer, 11Kv / 433 Volts ( At No Load ) Ac 3 Phase 50Hz, 160Kva Capacity, Core Type, Double Copper Wound, Oil Immersed, Naturally Cooled, Oil Natural Air Natural ( On An ) With External Cooling Tubes, Delta Connected On Primary Side ( Hv ) And Star Connected On Secondary Side ( Lv ) In Accordance With Vector Group Dyn-11 ( Vector Group ) With Neutral Brought Out On Secondary Side ( Lv Side ) And Having Taping At 0 ( Plus / Minus ) 2.5%, ( Plus / Minus ) 5%, & ( Plus / Minus ) 7.5% On Hv Side To Be Charged By Means Of Hands Operated Off Load Tap Changer Gear. Switch Handle Shall Be Provided With The Locking Arrangement Along With Top Position Indicator.The Transformer Shall Be Is:1180 ( Part-I ) 2014 With Maximum Total Losses As Per Energy Efficiency Level 2 Of Is:1180 ( Part I ) 2014 And Shall Comprise Of The Following: A ) Ht Cable Box On Primary Side Including All Accessories As Required. B ) One Cable Box On Lv Side ( Secondary Side ) Consisting Of Four Nos Porcelain Bushing With Copper Rods. Complete With Nuts And Washers With Two Nos Of Cable Glands Suitable For Reception Taking Out Of Xlpe Insulated Heavy Duty Armoured Cables Including Glands, Joints And Jointing Materials Complete. C ) Oil Conservator With Filter Type Drain Valve And Oil Level Gauge.D ) De-Hydrating Breather With First Fill Dehydrating Agent ( Silica Gel ) E ) Explosive Vent. F ) Thermometer Pocket On Tank Cover 57 G ) One No 100Mm Dia, Dial Type Thermometer, Vapour Pressure Type, Having Range 0-120°C With Metal Guard Having Maximum Perimeter Reading Temperature Indicatorwith Resisting Device For Transformer.H ) Two Nos Earth Terminals For Body Earthing And Two Nos Earthing Terminals For Neutral Earthing. J ) Rating Plate And Terminal Marking Plate K ) Oil Level Gaugel ) Oil Drain Filter Valvem ) Lifting Lugsn ) Oil Filling Hole With Cap / Plug With Connecting Plate Completeo ) Air Release Valve Vent With Plug P ) Four Plain Solid Cast Steel Detachable Rollersq ) First Filling Of New Transformer Oil Is-335 / 93 ( Forth Revision ) Marked Filtered And Tested Upto 50 Kv Di Electric Strength At 2.5Mm Air Gap Between Testing Electrodes.Accessories As Per Is-1180 ( Part I ) :2014. Note: Certificate Of Di Electric Strength Shall Be Submitted By Contractor. 58 Notes :- ( I ) Routine Test As Per Is, Shall Be Carried Out At The Works. Type Test Including Temperature Rise Test Shall Also Be Carried Out At Factory. Site Tests Are Also To Be Carried Out In Presence Of Company Rep. All The Tests Whether At Factory / At Site Are To Be Conducted In Presence Of Mes Rep And All Test Certificates Duly Signed By All Concenerned To Be Submitted By The Contractor To The Dept. ( Ii ) The Equipment Should Carry A Gurantee Of 30 Months From Date Of Despatch Or 24 Months Form Date Of Completion Of The Contract Whichever Is Later. Any Defect During This Period Will Be Attended In A Period Of Three Days Including Spares And Labour. ( Iii ) The Errection Of Transformer Shall Be Done As Per MnufacturerS Auth Rep & Certificate In This Regard Shall Be Submitted By Contractor Duly Signed By Auth Rep Of Manufacturer & Engr-In-Charge. ( Iv ) Rtcc Panel Shall Be Suitable For Automatic Valtage Regulation With Master Follower Scheme With Tap Position Indicator As Per Tap Indicatioin In The Oltc Mechanism. Rtcc Should Also Be Provided With Central Gear In Respect Of Fan On / Off Indication, Auto & Manual Control Switch , Ac Supply On And Tap Changer In Progress Indication Lamp, Tap Struck Indication And Alarm. ( V ) The Core Shall Be Constructed From High Grade Non Ageing, Prome Good Crgo With M4 Grade Or Vetter Silicon Steel Laminationi And Shall Be Og Bottle Ness Design. ( Vi ) Manufacturer Shall Have In House Automatic Core Cutting Facility To Ascertain That There Is No Mixing Of Second Grade Core. ( Vii ) Manufacturer Shall Have In House Nabl Accredited Lab To Ascertain The Authenticity Of Test Result. 59 Supply, Installation, Testing And Commissioning Of Servo Voltage Stabilizer Fully Automatic Micro Processor Based Control Card Of Capacity 150Kva Three Phase, Oil Cooled, Indoor Type And Designed For Input Variation Between 300V To 480V Output Voltage Stabilized At 415 Volts With Accuracy Of +-1% And Speed Of Voltage Correction Should Not Be Less Than 8V / Sec, Input Frequency 47 To 53 Hz Having Facility To Auto And Manual Operation, No Load Loss Should Be Less Than 0.5% Operating Temp -15°C To 45°C Above Ambient And Suitable To Operate With Unbalanced Load Including Initial Oil Filling Upto Appropriate Level With New Transformer Oil And Having All Strandard Accessories ( I.E Voltmeter, Amp Meter, Set Of Cts Of Appropriate Ratio, Selector Switch, Sufficient Nos Of Led Indicator Lamps, Togal Switch For Auto And Manual Mode Push Buttons For Voltage Lowe / Raise And Indication For Bypass Arrangements Etc ) Complete All As Specified And Directed With And Including Following Additional Features:-A ) High And Low Voltage Cut Off System. B ) Single Phase Prevention And Reverse Phase Protection System.C ) Over Load And Short Circuit Protection By Provided Mccb Of Suitable Amps And Ka Rating 4 Pole Having Adjustable Thermal And Adjustable Magnetic Setting. D ) Incoming Control By Providing Mccb Of 315 Amps And 36 Ka Rating 4 Pole With Adjustable Thermal Magnetic Setting.E ) By Pass Arrangement By Providing On Load Changeover Switch 4 Pole Of 315 Amps Rating. 60 Supply, Install, Testing And Commissioning Oflt Feeder Piller Box Outdoor Type Made Out Of 3.15 Mm Thickcrca Sheet And Ms Angle Iron Frame With Weather Proof Canopy, Mounted On Pcc Pedestal, Cubical Type, Front And Rear Side Openable, Compartment Type With Hinged Door Ligting Lugs 2 Nos, Earthing Strips At Rear Side, Bottom Detachable Gland Plate Complete With Suitable Size Zinc And Passivated Nut, Bolts Spring And Washers And Locking Arrangement For Each Compartment, Provision Of Air Vent, Dust And Vermin Proof, Provision Of Cable Alley With 400 Amps Rated Aluminium Bus Bar Having 1100 Volts Grade Sleaving And Internal Connection Should Be Provided With Aluminium Strips Of Suitable Size And To Accommodate And Including The Following Mccbs Duly Painted With 2 Coats Powder Coating Over A Coat Of Anticorrosive Red Oxide Primer Should Accomodate The Following Accessories. 61 Mccb 4 Pole 250 Amps 35 Ka ( Incoming ) -01 Nos 62 Mcb 32A Spn - 02 Nos 63 Mccb 3 Pole 100 Amps 25 Ka ( Outgoing ) -02 Nos 64 Time Switch 20 Amp, 415V, 3 Phase -01 Nos 65 Digital Ammeter With Suitable Cts Rating And Selector Switch-1 Set 66 Digital Volt Meter 0-500V With Selector Switch-1 Set 67 Led Type Indication Lamps With Switches And Fuses ( R, Y, B ) - 1 Set 68 Note: ( I ) The Rate Quoted Is Inclusive Of Necessary Cts, Control Wiring And Instrument Fuse Holder. 69 Supplying, Transporting, Erecting And Fixing Of Steel Tubular Swaged Poles Type 410, Sp-55 ( 11 Metres ) With 300Mmx300mmx6mm Cast Iron Base Plate, Finial Tapper Plug, Bolts, Nuts And Screws And Making Holes As Per Requirement All As Specified Including Factory Painted With Two Coats Of Black Bituminouspaint Internally Throughout And Externally For Embedded Portion And Applying One Coat Of Red Oxide Primer, Making 05 Nos Strips Each 30Cm High With Super Enamel Paint ( Black And Yellow / White ) From Ground Level / Coping Upto 1.5M Painting With Two Coats Of Aluminium Paint For The Remaining Height Complete All As Specified And Directed.Note:- Necessary Excavation & Earth Work And Pcc In Coping / Foundation Shall Be Measured And Paid For Separately . 70 Supply And Fixing Switch Air Break Gang Operated Triple Pole, Mechanically Operated From Ground Level Mounted On 12 Insulators Outdoor Type Suitable For Vertical Installations Single Break Provided With Locking Arrangement For Operating Handle Including Seven Levers Navtal Lock Consisting Of Mild Steel Channel Ht Post Top Insulator Copper Alloy High Pressure Assembly, Operating Rod Of 25Mm Dia Medium Grade G.I. Pipe Including Fuse Barrels Of Required Capacity To Suit The Load At Site And Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer On Ms Work Complete Conformimg To Is : 1018-1972 With Continous Current Rating 200 Amps 11 Kv Grade Complete All As Specified And As Directed. 71 Supply & Fixing Cubical Type Cablejunction Boxof Size 260 X 210 X 116 Mm, Fabricated Out Of 1.6 Mm Thick Crca Sheet For Street Light Pole, Mounted Junction Box / Terminal Box Suitable For Mounting On Round Poleand Suitable Arrangement For Fixing Bracket Complete With And Including One Mcb 6 Amps Capacity Single Pole And Suitable To Terminate Loop In / Out Cables Upto 35 Sqmm Complete All As Specified And Directed. 72 Supply And Fixing Led Street Light Fitting 60 Watt 230 V Ac Outdoor Type With High Pressure Die Cast Aluminum Hosing And Heat Resistant Complete With Driver, With Impact And Corrosion Resistant Including Thermal Management In Multiple Optics Complete With Ip 65 / 66 Protection Including Coper Conducted Pvc Insulated Unsheathed Of Size 1.5 Sqmm 3 Core For Service Connection From Junction Box Complete All As Specified And Directed. Note : The Contractor Shall Be Produced The Two Yrs Warranty Card During Supply. 73 Supply And Fix Gi Pipe Bracket, Made Out Of Gi Pipe 40 Mm Dia Light Grade, 1.2Mtr Long, Bend To The Shape 120 Degrees Angle, Including Clamps-02 Set Made Out Of Ms Flat ( 50X6mm ) Duly Bend To Shape For Pcc / Steel Tubular Pole , Nuts, Bolts And Washers Etc, Including Two Coats Of Synthetic Enamel Paint Over A Coat Of Red Oxide Primer On Ms Work Complete All As Specified And Directed. 74 Material & Labour For Cutting Of Existing Road 3.75M Wide And Laying Of Pcc 1:4:8 Type D-2Under 100 Mm Bore Np2 Pipe And Cover The Pipe With Pcc1:3:6 Including Packing Under Hauching Against The Sides Of Pipe Not Exceeding 25 Cm Etc Including Using Necessaryform Work Complete All As Specified. 75 M&L Forsand Cushioning In Trenches With A Layer Of Sand 80 Mm Thick Before Laying Of Cable And 150 Mm Thick After Laying Of Cable For Protection Of Cablecomplete All As Specified And Directed. Note :- Punned Thickness Shall Be Measured And Paid As Per Ssr Part-1 2009. 76 Material & Labour For Sub Class Brick Laid Dry Width Wise Across The Cable In Trenches For Protection Of Cable Complete All As Specified. 77 Supply And Fixing Ht Lighteningarrestors For Outdoor Use, Non-Linear Resistor Type, Capacity 10 Ka Complete With All Fittings, Suitable For 11 Kv Complete All As Specified And Directed. 78 M&L For Earthing Complete With Galvinised Steel Earthplate Electrode 60 Cm X 60Cm X 6Mm Thickburied Directly In Ground ( Earth Pit Notless Than2.25 Mtr Deep Belownormal Groundlevel ) With Top Edgeof Platenot Less Than1.5 Mtr Belownormal Ground Level , Connectingto Galvanised Iron Earth Strip 32X6 Mm, By Means Of Bolt Nuts, Check Nutsnutsand Washer Of Galvanised Medium Grade Pipe 15Mm Diaupto 7.5 Mtr Including Provnof Concretepit Inpcc ( 1:3:6 ) Type C-1 Using20 Mm Graded Stone Aggregates, With Fair Finish , Internal Surface Of Concrete Chamber Shall Be Given 15Mm Thick Plaster In Cm 1:4 , Funnel With Wire Gauge ( 0.68Mm ) 8Mesh Per Liner Inch , 80 Mm Thickrcc Pit Cover 320Mmx320mm Of Concree ( 1:2:4 ) Type B-1 Using 20 Mm Aggregate Reinforcedwith Xpm Jalli And Charcoal Dust And Common Salt All As In Shown In Electrical Plate No-03 Of Mes Ssr Pt-I And Specified Including Provision Of Earth Lead Strip Protected By 40 Mm Dia Light Grade Gi Pipe And Watering Pipe Shall Be 20 Mm Dia Medium Grade And Including All Excavation And Earth Work And Connecting The Earthing To And Earthingtest Point / Transformer Neutral / Body / Lt Panel Etc. And Testing On Completion , Complete All As Specified And Directed ( External Electric=12, Dg Set=4 ) Note: The Unit Quoted Rate Of Earthing Shall Be Deemed To Included Cost Of 7.5 M Longgi Earth Strip 32X6 Mm And Protection Pipe Of 40 Mm Bore Light Grade, Gi 20Mm Dia Medium Grade Watering Pipe. Any Variation In Length Shall Be Adjusted Through Deviation Order. 79 Dg Set Works ( Schedule A Part-Xv ) 80 Supply, Installation Testing & Commisioning Of Silent Type Diesel Engine Driven Generating Set With Governing Class G2 Incl Sound Reducing Canopy ( Sound Level Not More Then 75 Decibal Distance 1 Mtr ) 14 Gauge As Per Proper Guideline Issued By Central Pollution Control Board, 415 Volts, 3Phase 50Hz Supply Complete With Pannel For Automatic Starting On Main Failure Control Panelsuitable For Giving An Output Of 82.5 Kva After Considering Derating Factor Confirming To Is-1601 At 2750 Metre Altitude Above Mean Sea Level And Capable Of Operating Between Temperature Range ( -20°C To +40° C ) And Alternator Of Suitable Capacity Not Less Than 140Hp @ 1500 Rpm The Dg Set Comprise Of Amf Panel With Auto Change Main To Generator And Vice Versa Self Starterwith Batteries Water Cooled And Comprising All Standard Fittings And All Piping Etc As Belowa ) Alternator: Directly Coupled With Engine And Suitable To Produce 415 Volts, 3Phase 4 Wire System, 50Hz 0.8Pf @ 1500Rpm Of Capacity 82.5 Kva All As Per Is:13364 And Upto Date Amendments With H Class Insulation Selfexcited Self Regulated, Screen Protected Drip Proof Type With Two End Shield Ball / Roller Bearing With Damper Winding In Each Pole All As Specified And Directed.B ) Engine: Water Cooled Diesel Engine ( Cpcb Norms Compliance ) Developing Min 140 Hp Or As Recommended By The Manufacturer For 2750 Mtr Altitude Having Self Start Engine ( Including Batteries With Provn Of Charging The Batteries And Leads ) Suitable To Drive Above Specified Alternator Completewith Foundation ( Foundation Design As Per Oem ) As Per Is:10001 / 10002, Coupled Directly Through Flexible Coupling , Multi Cylinder Four Stroke, Cold Starting 1500 Rpm Industrial Type With Ai Electronic Governer Suitable To Regulate Speed Of Dg Set From No Load To Full Load Completed With Fuel Tank Of Cap As Per Manufacturer Recommendations, Fuel Lines, Exhaust Pipe Duly Insulated With Asbestos Rope And With Support And Silencer Mufflers Etc For Continous Operation And Standard Accessories, Sump Pre Heaters, Cold Start Kit Etc All As Specified And Directed. 81 C ) Canopy: Canopy Enclosure Shall Be Powder Coated And Fabricated Out Of Powder Coated After Passing Through Seven Tank Processes 16 Swg Crca Ms Sheet And Lockable Doors Should Be Provided In Canopy With Lockable Fuel Filling Arrangement Provided External To The Canopy.The Exhaust System And Noise Suppresor Shall Be Provided With Thermal Insulation By Using Fire Retardant / Non Lighting Foam To Prevent Excess Heat Radiation On The Engine And Safe Operator.Absorption Type Non Resistance Residential Silencer Shall Be Provided To Suppress Exhaust Noise From The Engine.D ) Alignment And Fuel Tank : Alternator And Engine Aligned On A Common 14 Swg Crca Ms Base Frame Complete With Ms Fuel Tank Fabricated Out Of 16 Swg Crca Ms Sheet And Is Part Of Base Frame Complete With Drain Valve, Air Vents Inlet And Outlet Connections As Per Oem Recommendations.E ) Control Panel :Microprocessor Based Automatic Operated Standard Alternator Control Panel Fabricated Out Of Sheet Steel Angle Iron Structure Acid Treated For Anti Corrosion Floor Mounting Cubical Pattern Powder Coated Dust And Vermin Proof Complete With Internal Wiring And With The Followings As Per Oem Recommendations. 1 ) Powder Coated Control Pannel Manufactured With Crca Sheet Provides 2 ) Mccb Of Suitable Ratingwith Short Circuit Protection3 ) Controller Which Displays Voltage, Current, Kw, Pf, Frequency, Kwh 4 ) Indicating Lamps For Load On And Set Running 5 ) Audio Visual Warning : Low Oil Pressure, High Coolant Temperature, Low Battery Voltage, Low Fuel Level 6 ) Shut Down With Audio Visual Annuation : Engine Over Speed, Engine Under Speed, High Canopy Temp, Low Fuel Level, Over / Under Voltage. 7 ) Current Transformers Of Suitable Ratings 8 ) Copper Cables Of Suitable Capacity With Incoming And Outgoing Terminations.9 ) Control Fuses Duly Wired And Ferruled 10 ) Approved By Arai The Nodal Agency Of Cpcb 11 ) Residential Type Exhaust Silencer Is Mounted On The Enclosure.12 ) Illumination Arrangements Inside The Canopy.13 ) Cold Start Kit14 ) Exhaust Silencer Should Be As Per Cpcb Norms 82 F ) Maintenance Spares: ( I ) Fuel Filter Element - 02 Nos ( Ii ) Oil Filter Element - 03 Nos ( Iii ) Element Air Cleaner Outer-06 Nos ( Iv ) V Belt-02 Nos ( V ) Filter Lubricant Oil Bypass - 02 Nosg ) Dg Set Shall Be Supplied Alongwith Acoustic Enclosure Of The Manufacturer Suitable For 82.5 Kva Dg Set As Per Cpcb Norms. Notes: The Quoted Rates Shall Be Deemed To Include Cost Of Following :- ( I ) Capacity Of Alternator At 2750 M Altitude Ac 3 Phase 415 Volts 50 Hz And As Recommended By The Manufacturer For Above Sized Dg Set. ( Ii ) Pcc Platform As Per Manufacturer Design ( Iii ) Engine And Alternator Shall Be Assembled On Common Steel Frame By The Manufacturer Itself And Not By Rep / Authorised Agent / Sister Concern Etc. ( Iv ) Engine Shall Designed Keeping In Consideration Of De Rating Factor For 2750 M Altitude. ( Vi ) Contractor Shall Produced A Copy Of Approved Cerrtificate To Authinticate The Above From The Oem / De. 83 Notes:- The Quoted Rates Shall Be Deemed To Include Cost Of Following:- ( I ) Capacity Of Alternator At 2750 Meters Altitute 82.5 Kva, Ac 3 Phase, 415 Volts, 50 Hz. And As Recommended By The Manufacturer For Above Sized Dg Set . ( Ii ) Pcc Platform As Per Manufacter Design . ( Iii ) Engine And Alternator Shall Be Assembled On Common Steel Frame By The Manufacturer Itself And Not By Rep / Authorised Agent / Sister Concern Etc. ( Iv ) Engine Shall Be Designed Keeping In Consideration Of De-Rating Factor For 2750 Meters Altitute. ( V ) Installation, Testing And Commissioning Of Gen Set Shall Be Done In Presence Of MaufacturerS Engineer And Not By Any Authorised Person. ( Vi ) Dg Set To Be Tested For 12 Hrs Contineously As Following. All Testing Materials And Fuel To Be Provided By The Contractor. No Load = 15 Minutes, 25% Of Rated Load = 30 Minutes, 50% Of Rated Load = 30 Minutes, 75% Of Rated Load = 30 Minutes, Full Load = 4 Hr, 110% On Rated Load = 30 Minutes, Full Load = 4 Hr, 75% Of Rated Load = 30 Minutes, 50% Of Rated Load = 30 Minutes, 25% Of Rated Load = 30 Minutes, No Load = 15 Minutes. ( Vii ) Contractor Shall Produced A Copy Of Approved Certificate To Authenticate The Above From The Oem / De 84 Central Heating System Works ( Schedule A Part-Xvi ) 85 Design, Supply, Installation , Commissioning And Testing Of Central Heating Plant Using Oil Fired Glycol Based Hot Water Generator ( Kerosene / Hsd Oil As Fuel ) Suitable For Operation At 50Hz, Three Phase 4 Wire, 433 / 230 Volts, Ac Supply, Complete For Maintaining The Temperature Inside The Building At 20°C± 2°C During Winter For The Buildings At S No 3.01 Of Boq ( Schedule A Part-I Section-I ) . The Temperature Should Be Maintained Athaws Gulmarg As Per The Data Sheet Given In Particular Specifications At Ambient Temperature Upto The ( - ) 18°C At The Height Of 2750 Mtr Above Msl . 86 Chs Plant Should Comprise Of Boilers ( 2 Working + 1 Stand By ) , Glycol Solution Circulation Centrifugal Pumps ( 1 Working + 1 Stand By ) , Glycol Solution Make Up Centrifugal Pumps ( 1 Working + 1 Stand By ) , Flue Gas Exhaust Pipe Connected To Chimney As Per Cpcb Norms ( 01 Nos With Each Boiler ) , Expansion Tank, Glycol Fluid Tank, Underground Bulk Oil Storage Tank ( Not Less Than 10 Kl ) , Day Oil Storage Tank ( Not Less Than 990 Ltrs ) , Transfer Gear Oil Pumps Kerocine Oil ( 1 Working + 1 Stand By ) , Kerosene / Hsd Oil Piping Of Suitable Size With Necessary Accessories, Hot Glycol Fluid Piping Of Suitable Size With Suitable Insulation And Necessary Accrssoires, Suitable Valves, Wall Mounted Fcus With Remote Control, Wall Mounted Towel Radiators In Each Toilets, 1St Fill Of Glycol Charge ( The Mixture Of Water And Glycol Shall Have Freezing Temperature Of -25 Deg C ) , Lt Panel With Necessary Safety Control System With All Accessoires Including All Necessory Electric Connection With The Equipment ( Cables Shall Run In Cable Tray Of Suitable Size ) , Danger Notice Plate, “ No Smoking And “ Flammable” Sign Board As Per Requirement Of Petroleum Rules And Ccoe Nagpur And All Other Necessary Items For Otm Accn 140 Ors.Note : All The Equipment & Accessories Should Be As Per Appropriate Codel Provisions. 87 Notes :The Rates Quoted By The Tenderer For The Work Deemed To Include The Provision Of Following :- ( I ) Pcc / Rcc Foundation For Chimney, Pumps, Boilers, Tanks And Other Equipments As Specified By The Oem. ( Ii ) Submission Of Whole Scheme Of Chs Including Boiler And Pumps Capacity Design, Fcus Capacity Design, Piping Design From Plant To The Rooms For Circulation Of Glycol Mixture And Technical Specification Duly Vetted By Iit ( Not By Professor In His Individual Capacity ) Within 90 Days Form Date Of Commencement Of Work For Approval Of Accepting Officer. The Invoice Of The Payment Made To Institute For Vetting The Whole Scheme To Be Submitted To The Department. ( Iii ) All The Electric Panels Should Be As Per Suitable Ingress Portection Code And Cpri Approved. All The Equipment & Accessories Should Be As Per Appropriate Codal Provisions. ( Iv ) All The Miscellenous And Other Items, If Any Required, As Per OemS Design. 88 Schedule A Part-Xvii ( Manning And Operation During Defect Liability Period ) 89 Outsourcing Of Servicesfor Manning And Operationof Central Heating Plantconsisting Of Glycole Mixture Based Hot Water Generater, Pumps, Day Oil & Bulk Oil Tank, Glycol Make Up Tank, Piping, Control Paneland All Other Connected Items At Haws Gulmarg For 1St Year After Completion Of Phase-Ii During Defect Liability Period By Deploying 1 No Trained Operator Per Shift ( Each Shift Of 08 Hours ) ( One Operator Per Plant Per Shift For One Plant ) In Three Shifts Per Day Including Sundays And Holidays Complete All As Specified Anddirected By Engineer-In-Charge .Notes: 1.Operator Will Operate The Plant And Ensure Proper Functioning.2. Maintain A Record Of Hours Run Of Each Plantin A Appropriate Log Sheet On Daily Basis . 3. The Operator Will Not Leave The Duty Place Without Permission . 4 . Any Minor Repairs Required Will Be Done After Informing The Department. 5. Outsourcing Staff Will Change After Every 11 Months.6. The Qualification Of Operator Shall Be Iti Passed Cerificate Having Minimum 03 Years Practical Experience. 90 Outsourcing Of Servicesfor Manning And Operationof Central Heating Plant Consisting Of Glycole Mixture Based Hot Water Generater, Pumps, Day Oil & Bulk Oil Tank, Glycol Make Up Tank, Piping, Control Paneland All Other Connected Items At Haws Gulmarg For 2Nd Year After Completion Of Phase-Ii During Defect Liability Period By Deploying 1 No Trainedoperator Per Shift ( Each Shift Of 08 Hours ) ( One Operator Per Plant Per Shift For One Plant ) In Three Shifts Per Day Including Sundays And Holidays Complete All As Specified Anddirected By Engineer-In-Charge .Notes: 1.Operators Will Operate The Plants And Ensure Proper Functioning.2. Maintain A Record Of Hours Run Of Each Plantin A Appropriate Log Sheet On Daily Basis . 3. The Operator Will Not Leave The Duty Place Without Permission . 4 . Any Minor Repairs Required Will Be Done After Informing The Department. 5. Outsourcing Staff Will Change After Every 11 Months.6. The Qualification Of Operator Shall Be Iti Passed Cerificate Having Minimum 03 Years Practical Experience.

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 02-Nov-2022 Corrigendum No 2 Other 28-11-2022
2 02-Nov-2022 CorrigendumNo01 Date 28-11-2022
3 07-Nov-2022 CorrigendumNo04 BOQ 28-11-2022
4 07-Nov-2022 Corrigendum03 Other 28-11-2022
5 11-Nov-2022 Corrigendum No 05 Date 05-12-2022

Key Value

Document Fees
INR 3000 /-
EMD
INR 900000.0 /-
Tender Value
INR 11.50 Crore /-

BOQ Items

Name of Work: PROVN OF OTM FOR 140 OR IN DESIGN & BUILD BASIS AT GULMARG
Sl. No. Item Description
1Note: (i) Please refer Schedule "A" Notes givenin tender documents. (ii)This schedule "A" Part-I Section-I, Part-XI to XVII is not estimatedby MES and the estimated rate indicated as "Rs. 0.00" under Col. 5 signifies this fact only.
2LUMPSUM/ OTHER PRE-PRICED PROVISIONAL SCHEDULES OF WORKS
3Lump sum price worked out by the contractor for BUILDING WORKS as listed in Schedule "A" Part-I Section-II brought forward from serial page No. 38
4Lump sum price worked out by the contractor for INTERNAL ELECTRIFICATION WORKS as listed in Schedule "A" Part-II brought forward from serial page No. 41
5Lump sum price worked out by the contractor for INTERNAL WATER SUPPLY WORKS as listed in Schedule "A" Part-III brought forward from serial page No. 45
6Lump sum price worked out by the contractor for SEWAGE DISPOSAL WORKS listed in Schedule "A" Part-IV brought forward from serial page No. 47
7Lump sum price worked out by the contractor for ROAD, PATH AND CULVERTWORKSas listed in Schedule "A" Part-V brought forward from serial page No. 50
8Lump sum price worked out by the contractor for AREA DRAINAGE WORKS as listed in Schedule "A" Part-VI brought forward from serial page No. 52
9Lump sum price worked out by the contractor for PROTECTIVE / RETAINING WALL WORKSas listed in Schedule "A" Part-VII brought forward from serial page No. 54
10Lump sum price worked out by the contractor for EXTERNAL WATER SUPPLY WORKS as listed in Schedule "A" Part-VIII brought forward from serial page No. 56
11Lump sum price worked out by the contractor for SITE CLEARANCE & EARTHWORKS as listed in Schedule "A" Part-IX brought forward from serial page No. 58
12Lump sum price worked out by the contractor for EXTERNAL ELECTRIFICATION WORKS as listed in Schedule "A" Part-X brought forward from serial page No. 61
13BUILDINGWORKS BASED ON DESIGN & BUILD (SCHEDULE "A" Part I Section I)
14Design, supply and erect, PEB buildings with wall of LGSF based on rapid constructiontechnology for construction of Single Living Accn for 140 ORs (Double Storey) complete all as specified and shown on drawings.
15INTERNAL ELECTRIFICATION WORKS (SCHEDULE "A" PART-XI)
16Material and Labour for point wiring complete withPVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including PVC conduit (Medium duty) of suitable size (as per conductor run) with all fittings and accessories concealed in wall and ceiling portion inculding concealed sunk in pressed steel terminal bozes of not less than 2mm thick required size factory made and painted with synthetic enamel paint black paint with including top cover 3mm thick plastic laminated sheet (Make : Hylum) of required colour fixed with brass screws and cup washers with and including 1.5 sqmm FRLS multi stranded copper conductor as continuous earth wire drawn in same concealed conduit, connected to main earth and earth dolly including cutting chases and making good as per existing specification for One Light / fan/exhaust fan point controlled by one way switch 5Amp complete all as specified and directed.
17Material and Labour for point wiring complete withPVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including PVC conduit (Medium duty) of suitable size (as per conductor run) with all fittings and accessories concealed in wall and ceiling portion inculding concealed sunk in pressed steel terminal bozes of not less than 2mm thick required size factory made and painted with synthetic enamel paint black paint with including top cover 3mm thick plastic laminated sheet (Make : Hylum) of required colour fixed with brass screws and cup washers with and including 1.5 sqmm FRLS multi stranded copper conductor as continuous earth wire drawn in same concealed conduit, connected to main earth and earth dolly including cutting chases and making good as per existing specification for One Light point controlled by two way switch 5Amp complete all as specified and directed.
18Material and Labour for point wiring complete withPVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 1.5 Sq mm (Nominal area) drawn through and including PVC conduit (Medium duty) of suitable size (as per conductor run) with all fittings and accessories concealed in wall and ceiling portion inculding concealed sunk in pressed steel terminal bozes of not less than 2mm thick required size factory made and painted with synthetic enamel paint black paint with including top cover 3mm thick plastic laminated sheet (Make : Hylum) of required colour fixed with brass screws and cup washers with and including 1.5 sqmm FRLS multi stranded copper conductor as continuous earth wire drawn in same concealed conduit, connected to main earth and earth dolly including cutting chases and making good as per existing specification for One three pin 5Amp switch socket outlet point on independent board complete all as specified and directed.
19Material and Labour for point wiring complete withPVC insulated unsheathed 1100 volt grade FRLS cable with multi stranded copper conductor of size 2.5 Sq mm (Nominal area) drawn through and including PVC conduit (Medium duty) of suitable size (as per conductor run) with all fittings and accessories concealed in wall and ceiling portion inculding concealed sunk in pressed steel terminal bozes of not less than 2mm thick required size factory made and painted with synthetic enamel paint black paint with including top cover 3mm thick plastic laminated sheet (Make : Hylum) of required colour fixed with brass screws and cup washers with and including 1.5 sqmm FRLS multi stranded copper conductor as continuous earth wire drawn in same concealed conduit, connected to main earth and earth dolly including cutting chases and making good as per existing specification for One six pin socket outlet two in one 6/16 Amp point on independent board complete all as specified and directed.
20Supply and fixing TV socket completeall as specified and directed.
21Supply and fixing Telephone Socket RJ-11 completeall as specified and directed.
22Material and labour for sub main wiring (concealed) complete with four single core 6.00 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit and conduit accessories including two single run of 6.00 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note:- Six runs of 6 sqmm cable and one run of PVC conduit shall be measured as one unit."
23Material and labour for sub main wiring (concealed) complete with two single core 2.50 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit and conduit accessories including one single run of 2.50 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note:- Three runs of 2.50 sqmm cable and one run of PVC conduit shall be measured as one unit."
24Material and labour for sub main wiring (concealed) complete with two single core 4.00 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit and conduit accessories including one single run of 4.00 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note:- Three runs of 4.00 sqmm cable and one run of PVC conduit shall be measured as one unit."
25Material and labour for sub main wiring (concealed) complete with two single core 6.00 Sqmm FRLS PVC insulated unsheathed stranded copper conductor cable drawn through in and including 20 mm dia rigid non-metallic PVC conduit and conduit accessories including two single run of 6.00 Sqmm FRLS PVC insulated unsheated stranded copper earth cable connected to common earth dolly complete and including cutting chasing in walls for concealed wiring using machine cutting and making good the disturbed surface all as specified and directed. Note:- Three runs of 6 sqmm cable and one run of PVC conduit shall be measured as one unit."
26Supply and fixing ceiling fans complete with blades, down rods with accessories, 230 V, 1200 mm sweep, minimum air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) and all accessories and including connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
27Supply and fixingexhaust fan made of sturdy Engineering plastic complete with louvers shutter including mounting frame, voltage 230V, 50 Hz, 1200 RPM, 36 watt, light duty, copper winding of sweep 250mm and all accessories and including connecting up with 1.50 sqmm three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
28Supply and fixingexhaust fan made of sturdy Engineering plastic complete with louvers shutter including mounting frame, voltage 230V, 50 Hz, 1350 RPM, light duty, copper winding of sweep 300mm and all accessories and including connecting up with 2.5 sqmm three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
29Supply and fixingexhaust fan made of sturdy Engineering plastic complete with louvers shutter including mounting frame, voltage 230V, 50 Hz, 1400 RPM, light duty, copper winding of sweep 450mm and all accessories and including connecting up with 2.5 sqmm three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
30M&L for Earthing complete with galvinised steel earthplate electrode 60 cm x 60cm x 6mm thickburied directly in ground (earth pit notless than2.25 mtr deep belownormal groundlevel)with top edgeof platenot less than1.5 mtr belownormal ground level , connectingto galvanised iron wire 4mm dia, protected by galvanised iron light grade pipe 15mm dia and galvanised iron water pipe medium grade 20mm dia upto 7.5 mtr including provnof concretepit inPCC (1:4:8) type D-2 using 40 mm graded stone aggregates, coping shall be PCC 1:3:6 type C1 using 20 mm graded stone aggregate, top cover 50mm thick of RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bars @80mm c/c both ways with angle iron frame, pit shall be given 15mm thick plaster in CM 1:4 , funnel with wire gauge (0.68mm) and charcoal dust and common salt all as in shown in electrical plate No-03 of MES SSR Pt-I and specified and including all excavation and earth work and connecting the earthing complete all as specified and directed Note: The unit quoted rate of earthing shall be deemed to included cost of 7.5 M long GI earth wire 4mm dia and protection pipe GI 15 mm dia light grade, GI 20mm dia medium grade watering pipe. Any variation in length shall be adjusted through deviation order.
31Supply and fixing energy efficient LED tube light fitting 1 x 20 watt, luminaire suitable for surface/pendant mounting, with white reflector cover fitted to the body, single tube mounting rail type, connector blcok complete prewired, incluidng one tube rod of 20 watt, connecting to ceiling rose with suitable copper conductor flexible cable complete all as specified and directed
32Supply and fixing LED building security light with pressure die cast aluminum housing with polycarbonate cover, finless design, dedicated peanut optics, > 100 lumen/W system efficiency, minimum 2500 system lumens, 45W system wattage (including driver), color temperature > 5700K, CRI>80, IP65 protection, IK07 ratingincluding suitable size of 1.5 meter long bend 25mm dia GI pipe (light grade, bend at 120°) with 40x 6mm FI clamps and fixing accessories (Nuts, bolts and washers) etc.The potted electronic driver with THD<10%, PF>0.95, LED fitting is complete all as per OEM specified and directed. LED driver and housing is of same make as of light fitting. All type of testing for photometry, electrical and electronic parameters is done in BABI approved lab complete all as specified and directed. Note: The unit quoted rate include the cost of painting with two coats of synthetic enamel paint over a coat of red oxide primer over MS work.
33Supply and fixing LED lamp 5 watt energy efficient, 220 volt, 50 Hz B22 cap, cool day light complete all as specified and directed.
34Supply and fixing warm white, wall mounted LED 11 watt, mirror light (indoor) complete all as specified and directed
35Supply and laying independent PVC conduit pipe confirming to IS: 9537 Part-III 1983, medium class, outer dia 25mm including cuttings chases on wall and making goodfor TV and Telephone point complete all as specified and directed.
36Supply and drawn in conduit telecom PVC insulated cable for indoor applicances confirming to TEC specifications G/W/IR06/02, 2 pair unarmoured, 0.5 ATC complete all as specified and directed.
37Supply and drawn in conduit CATV coaxial cable, (Electrolytic Grade solid annelaed coper conductor, Jelly Field, Aluminimum Foiled and Aluminium wire braided) 75 Ohms, RG 11 Foam signal losses db/100yds at 100 Mhz complete all as specified and directed.
38Supply and fixing factory made concealed sunk-in pressed steel terminal boxes of size 75x75x60mm, thickness of sheet not less than 2mm, painted with two coats of synthetic enamel paint (Black) over a coat of primer with and including top cover 3mm thick plastic laminated sheet of required colour fixed with brass screws and cup washers incluidng cutting chases for TV and Telephone socket mounting and making good the disturbed surfaces complete all as specified and directed.
39Supply and fixing verticle distribution board multiphase outgoing for mounting MCCB as incomer of rating 100 Amp, double door, 4 way, 415 volt, 50 Hz, with fixing arrangement on MS frame complete all as specified and directed.
40Supply and fixing MCCB suitable for verticle distribution board of make HPL, thermal setting fixed type, breaking capacity 25kA, 4 pole, 100 Amp complete all as specified and directed.
41Supply and fixing MCB SP 240 Volt, 50Hz , 10 KA, "C" series of rating06 to 32 Amp confirming to IS/IEC-60898-1 & IS/IEC-60947-2 completeall as specified and directed.
42Supply and fixing MCB SP 240 Volt, 50Hz , 10 KA, "C" series of rating63 Amp confirming to IS/IEC-60898-1 & IS/IEC-60947-2 completeall as specified and directed.
43Supply and fixing MCB SPN 240 Volt, 50Hz , 10 KA, "C" series of rating6 to 32 Amp confirming to IS/IEC-60898-1 & IS/IEC-60947-2 completeall as specified and directed.
44Supply and fixing MCB SPN 240 Volt, 50Hz , 10 KA, "C" series of rating40 to 63 Amp confirming to IS/IEC-60898-1 & IS/IEC-60947-2 completeall as specified and directed.
45Supply and fixing MCB TPN 415 Volt, 50Hz , 10 KA, "C" series of rating63 Amp confirming to IS/IEC-60898-1 & IS/IEC-60947-2 completeall as specified and directed.
46INTERNAL WATER SUPPLY WORKS (SCHEDULE "A" PART-XII)
47Supply and fixingtwo way bib taps 15 mm bore, cast copper alloy with crutch or butterfly handle,screwed down, screwed for iron pipe or for brass ferrule fancy type chromium plated complete all as specified and directed.
48Supplying and fixingangle valve cast copper alloy, chromium plated, screwed down, high pressure with crutch or butterfly handle, screwed both ends for 15mm bore iron pipe or for unions and fixed complete all as specified and directed.
49Supplying and fixing 15 mm bore Health faucet of approved quality chromium plated with flexible pipe 1.50 mtr long and making connection complete all as specified and directed.
50Supplying and fixing 15 mm borebrass CP WHB mixerfor mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed.
51EXTERNAL WATER SUPPLY WORKS (SCHEDULE "A" PART-XIII)
52Material and labour for construction of valve pit of size 60cmx60cmx60cm (internal dimensions) by excavation and earth work in any type of soil, removal, disposal of surplus spoil to a distance not exceeding 50m and depositing where directed, PCC (1:4:8) type D-2 (Using 40mm graded crushedaggregate) in foundation, brick masonary in cement mortar (1:6) using old size sub class "B" bricks, rendering 15mm thick in cement mortar (1:4) internally, neeru finished externally as the work proceeds in the same mortar, coping in 1:2:4 (using 20mm graded stone aggregate),angle iron frame (40x40x6mm), MS sheet cover 3.15 mm thick with sleeve piece, frame work, butt hinge 125mm size with handle 100mm of MS bar and locking arrangement, paintingall the exposed MS work with two coats of synthetic enamel paint of the tint as approved by the GE over a coat of red oxide primer and painting all the MS embedded in PCC with two coats of black bituminous paint including excavation and earth work, internal and three coats of white wash on exposed plastered/concrete surfaces complete all as specified and shown on drawings.
53Cutting into existing GI water main 80mm dia in position for inserting new Tee/Specials for branch connection of 50mm size including GI Tee 80x80x50mm complete all as specified and directed.
54EXTERNAL ELECTRIC SUPPLY WORKS (SCHEDULE "A" PART-XIV)
55Supply and errection of steel tubular swaged poles complete with cast iron base plate,finial taper plug,bolts,nuts and screws as specified type 410 SP-22 (8.5 metres long) including two coat of black bituminous paint internally throughout and externally upto embeded portion and applying two coats of synthetic enamel paint over a coat of red oxide primer with black n white strip of 30 CM each upto 1.5 mtr height and two coats of aluminium paint over a coat of red oxide primer externally on remaining exposed surface after preparation of surface and errection in position,Complete all as specified and directed. Note :- Excavation and earth work,PCC for foundation and coping channels ,Clamps nuts,bolts to be measured and paid separately.
56Supply,installation,testing and commissioning outdoor type,plinth mounted step down transformer,11KV/433 volts (at no load) AC 3 phase 50HZ,160KVA capacity,core type,double copper wound,oil immersed,naturally cooled,oil natural Air Natural(ON AN) with external cooling tubes,delta connected on primary side(HV) and star connected on secondary side (LV) in accordance with vector group DYN-11(vector group) with neutral brought out on secondary side (LV side) and having taping at 0 (plus/ minus)2.5%, (plus/minus)5%,&(Plus/minus)7.5% on HV side to be charged by means of hands operated off load tap changer gear. switch handle shall be provided with the locking arrangement along with top position indicator.The transformer shall be IS:1180(Part-I) 2014 with maximum total losses as per energy efficiency level 2 of IS:1180 (Part I)2014 and shall comprise of the following: a) HT cable box on primary side including all accessories as required. b) One cable box on LV side(Secondary Side) Consisting of four Nos porcelain bushing with copper rods. Complete with nuts and washers with two Nos of cable glands suitable for reception taking out of XLPE insulated heavy duty armoured cables including glands,Joints and jointing materials complete. c) Oil conservator with filter type drain valve and oil level gauge. d) De-hydrating breather with first fill dehydrating agent (Silica Gel) e) Explosive vent. f) Thermometer pocket on tank cover
57g) One No 100mm dia,dial type thermometer,Vapour pressure type,having range 0-120°C with metal guard having maximum perimeter reading temperature indicatorwith resisting device for transformer. h) Two Nos earth terminals for body earthing and two Nos earthing terminals for neutral earthing. j) Rating plate and terminal marking plate k) Oil level gauge l) Oil drain filter valve m) Lifting Lugs n) Oil filling hole with cap/plug with connecting plate complete o) Air release valve vent with plug p) Four plain solid cast steel detachable rollers q) First filling of new transformer oil IS-335/93(Forth revision) marked filtered and tested upto 50 KV di electric strength at 2.5mm air gap between testing electrodes.Accessories as per IS-1180(Part I):2014. Note: Certificate of Di electric strength shall be submitted by contractor.
58Notes :- (i) Routine test as per IS, shall be carried out at the works. Type test including Temperature rise test shall also be carried out at factory. Site tests are also to be carried out in presence of company rep. All the tests whether at factory/ at site are to be conducted in presence of MES rep and all test certificates duly signed by all concenerned to be submitted by the contractor to the dept. (ii) The equipment should carry a gurantee of 30 months from date of despatch or 24 months form date of completion of the contract whichever is later. Any defect during this period will be attended in a period of three days including spares and labour. (iii) The errection of transformer shall be done as per mnufacturer"s auth Rep & certificate in this regard shall be submitted by contractor duly signed by auth rep of manufacturer & Engr-in-Charge. (iv) RTCC Panel shall be suitable for automatic valtage regulation with master follower scheme with tap position indicator as per tap indicatioin in the OLTC mechanism. RTCC should also be provided with central gear in respect of fan ON/OFF indication, auto & manual control switch , AC supply On and Tap changer in progress indication lamp, tap struck indication and alarm. (v) The core shall be constructed from high grade non ageing, prome good CRGO with M4 grade or vetter silicon steel laminationi and shall be og bottle ness design. (vi) Manufacturer shall have in house automatic core cutting facility to ascertain that there is no mixing of second grade core. (vii) Manufacturer shall have in house NABL accredited lab to ascertain the authenticity of test result.
59Supply,installation,testing and commissioning of servo voltage stabilizer fully automatic micro processor based control card of capacity 150KVA three phase,oil cooled,indoor type and designed for input variation between 300V to 480V output voltage stabilized at 415 Volts with accuracy of +-1% and speed of voltage correction should not be less than 8v/Sec,input frequency 47 to 53 Hz having facility to auto and manual operation,No load loss should be less than 0.5% operating temp -15°C to 45°C above ambient and suitable to operate with unbalanced load including initial oil filling upto appropriate level with new transformer oil and having all strandard accessories (i.e Voltmeter,Amp meter,Set of CTs of appropriate ratio,Selector switch,sufficient Nos of LED indicator lamps,togal switch for auto and manual mode Push buttons for voltage lowe/raise and indication for bypass arrangements etc) complete all as specified and directed with and including following additional features:-a) High and low voltage cut off system. b) Single phase prevention and reverse phase protection system. c) over load and short circuit protection by provided MCCB of suitable Amps and KA rating 4 Pole having adjustable thermal and adjustable magnetic setting. d) Incoming control by providing MCCB of 315 Amps and 36 KA rating 4 pole with adjustable thermal magnetic setting. e) By pass arrangement by providing ON Load changeover switch 4 pole of 315 Amps rating.
60Supply, install, testing and commissioning ofLT feeder piller box outdoor type made out of 3.15 mm thickCRCA sheet and MS angle iron frame with weather proof canopy, mounted on PCC pedestal, cubical type, front and rear side openable, compartment type with hinged door ligting lugs 2 Nos, earthing strips at rear side, bottom detachable gland plate complete with suitable size zinc and passivated nut, bolts spring and washers and locking arrangement for each compartment, provision of air vent, dust and vermin proof, provision of cable alley with 400 amps rated aluminium bus bar having 1100 volts grade sleaving and internal connection should be provided with aluminium strips of suitable size and to accommodate and including the following MCCBS duly painted with 2 coats powder coating over a coat of anticorrosive red oxide primer should accomodate the following accessories.
61MCCB 4 pole 250 Amps 35 KA (incoming) -01 Nos
62MCB 32A SPN - 02 Nos
63MCCB 3 pole 100 Amps 25 KA (outgoing) -02 Nos
64Time Switch 20 Amp, 415V, 3 phase -01 Nos
65Digital Ammeter with suitable CTs rating and selector switch-1 set
66Digital Volt meter 0-500V with selector switch-1 set
67LED type indication lamps with switches and fuses (R,Y,B) - 1 set
68Note: (i) The rate quoted is inclusive of necessary CTs, control wiring and instrument fuse holder.
69Supplying, transporting, erecting and fixing of Steel tubular swaged poles type 410,SP-55 (11 metres) with 300mmx300mmx6mm Cast Iron base plate, finial tapper plug, bolts, nuts and screws and making holes as per requirement all as specified including factory painted with two coats of black bituminouspaint internally throughout and externally for embedded portion and applying one coat of red oxide primer, making 05 Nos strips each 30cm high with super enamel paint (Black and Yellow/white) from ground level/coping upto 1.5m painting with two coats of aluminium paint for the remaining height complete all as specified and directed. Note:- Necessary excavation & earth work and PCC in coping / foundation shall be measured and paid for separately .
70Supply and fixing switch air break gang operated Triple pole, mechanically operated from ground level mounted on 12 insulators outdoor type suitable for vertical installations single break provided with locking arrangement for operating handle including seven levers "Navtal" lock consisting of Mild Steel channel HT post top insulator copper alloy high pressure assembly, operating rod of 25mm dia medium grade G.I. pipe including fuse barrels of required capacity to suit the load at site and two coats of synthetic enamel paint over a coat of red oxide primer on MS work complete conformimg to IS : 1018-1972 with continous current rating 200 Amps 11 KV grade complete all as specified and as directed.
71Supply & fixing cubical type cablejunction boxof size 260 x 210 x 116 mm,fabricated out of 1.6 mm thick CRCA sheet for street light pole, mounted junction box/terminal box suitable for mounting on round poleand suitable arrangement for fixing bracket complete with and including one MCB 6 amps capacity single pole and suitable to terminate loop in/out cables upto 35 sqmm complete all as specified and directed.
72Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection including coper conducted PVC insulated unsheathed of size 1.5 Sqmm 3 core for service connection from junction box complete all as specified and directed. Note : The contractor shall be produced the two yrs warranty card during supply.
73Supply and fix GI pipe bracket, made out of GI pipe 40 mm dia light grade, 1.2mtr long, bend to the shape 120 degrees angle, including clamps-02 set made out of MS flat (50x6mm) duly bend to shape for PCC/steel tubular pole , nuts,bolts and washers etc, including two coats of synthetic enamel paint over a coat of red oxide primer on MS work complete all as specified and directed.
74Material & Labour for cutting of existing road 3.75m wide and laying of PCC 1:4:8 type D-2under 100 mm bore NP2 pipe and cover the pipe with PCC1:3:6 including packing under hauching against the sides of pipe not exceeding 25 cm etc including using necessaryform work complete all as specified.
75M&L forsand cushioning in trenches with a layer of sand 80 mm thick before laying of cable and 150 mm thick after laying of cable for protection of cablecomplete all as specified and directed. NOTE :- Punned thickness shall be measured and paid as per SSR Part-1 2009.
76Material & Labour for sub class brick laid dry width wise across the cable in trenches for protection of cable complete all as specified.
77Supply and fixing HT lighteningarrestors for outdoor use, non-linear resistor type, capacity 10 KA complete with all fittings, suitable for 11 KV complete all as specified and directed.
78M&L for Earthing complete with galvinised steel earthplate electrode 60 cm x 60cm x 6mm thickburied directly in ground (earth pit notless than2.25 mtr deep belownormal groundlevel)with top edgeof platenot less than1.5 mtr belownormal ground level , connectingto galvanised iron earth strip 32x6 mm, by means of bolt nuts, check nutsnutsand washer of galvanised medium grade pipe 15mm diaupto 7.5 mtr including provnof concretepit inPCC (1:3:6) type C-1 using20 mm graded stone aggregates, with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4 , funnel with wire gauge (0.68mm) 8mesh per liner inch ,80 mm thickRCC pit cover 320mmx320mm of concree(1:2:4) type B-1 using 20 mm aggregate reinforcedwith XPM jalli and charcoal dust and common salt all as in shown in electrical plate No-03 of MES SSR Pt-I and specified including provision of earth lead strip protected by 40 mm dia light grade GI Pipe and watering pipe shall be 20 mm dia medium grade and including all excavation and earth work and connecting the earthing to and earthingtest point/ Transformer neutral / body / LT panel etc. and testing on completion , complete all as specified and directed (External Electric=12, DG Set=4) Note: The unit quoted rate of earthing shall be deemed to included cost of 7.5 M longGI earth strip 32x6 mm and protection pipe of 40 mm bore light grade, GI 20mm dia medium grade watering pipe. Any variation in length shall be adjusted through deviation order.
79DG SET WORKS (SCHEDULE "A" PART-XV)
80Supply,Installation Testing & Commisioning of Silent type Diesel Engine driven generating set with governing class G2 incl sound reducing canopy(Sound level not more then 75 decibal distance 1 Mtr) 14 gauge as per proper guideline issued by Central pollution Control board,415 Volts,3Phase 50Hz Supply complete with pannel for automatic starting on main failure control panelsuitable for giving an output of 82.5 KVA after considering derating factor confirming to IS-1601 at 2750 Metre altitude above mean sea level and capable of operating between temperature range (-20°C to +40° C ) and alternator of suitable capacity not less than 140HP @ 1500 RPM The DG set comprise of AMF panel with auto change main to generator and vice versa self starterwith batteries water cooled and comprising all standard fittings and all piping etc as below a) Alternator: Directly coupled with engine and suitable to produce 415 Volts,3Phase 4 wire system,50Hz 0.8PF @ 1500RPM of capacity 82.5 KVA all as per IS:13364 and upto date amendments with H class insulation selfexcited self regulated,Screen protected drip proof type with two end shield ball/roller bearing with damper winding in each pole all as specified and directed. b) Engine: Water cooled Diesel Engine (CPCB Norms compliance) developing Min 140 HP or as recommended by the manufacturer for 2750 Mtr altitude having Self start engine (Including batteries with provn of charging the batteries and leads) suitable to drive above specified alternator completewith foundation (Foundation design as per OEM) as per IS:10001/10002,Coupled directly through flexible coupling ,Multi cylinder four stroke,Cold starting 1500 RPM industrial type with AI electronic Governer suitable to regulate speed of DG Set from No load to full load completed with fuel tank of cap as per manufacturer recommendations,fuel lines,exhaust pipe duly insulated with asbestos rope and with support and silencer mufflers etc for continous operation and standard accessories,Sump pre heaters,Cold Start kit etc all as specified and directed.
81c) Canopy: Canopy enclosure shall be powder coated and fabricated out of powder coated after passing through seven tank processes 16 SWG CRCA MS sheet and lockable doors should be provided in Canopy with lockable fuel filling arrangement provided external to the canopy.The exhaust system and noise suppresor shall be provided with thermal insulation by using fire retardant/non lighting foam to prevent excess heat radiation on the engine and safe operator.Absorption type non resistance residential silencer shall be provided to suppress exhaust noise from the engine. d) Alignment and fuel Tank : Alternator and Engine aligned on a common 14 SWG CRCA MS base frame complete with MS Fuel tank Fabricated out of 16 SWG CRCA MS sheet and is part of base frame complete with drain valve,air vents inlet and outlet connections as per OEM recommendations. e) Control Panel :Microprocessor based automatic operated standard alternator control panel fabricated out of sheet steel angle iron structure acid treated for anti corrosion floor mounting cubical pattern powder coated dust and vermin proof complete with internal wiring and with the followings as per OEM recommendations. 1) Powder Coated control pannel manufactured with CRCA sheet provides 2) MCCB of suitable ratingwith short circuit protection 3) Controller which displays voltage,current,KW,PF,Frequency,Kwh 4) Indicating lamps for "LOAD ON" and "Set Running" 5) Audio Visual Warning : Low oil pressure,high coolant temperature,low battery voltage,low fuel level 6) Shut down with audio visual annuation : Engine over speed,Engine under speed,High canopy temp,Low fuel level,Over/Under Voltage. 7) Current transformers of suitable ratings 8) Copper cables of suitable capacity with incoming and outgoing terminations. 9) Control fuses duly wired and ferruled 10)Approved by ARAI the nodal agency of CPCB 11) Residential type exhaust silencer is mounted on the enclosure. 12) Illumination arrangements inside the canopy. 13) Cold start kit 14) Exhaust silencer should be as per CPCB norms
82f) Maintenance Spares: (i) Fuel filter element - 02 Nos (ii) Oil Filter element - 03 Nos (iii) Element Air cleaner outer-06 Nos (iv) V Belt-02 Nos (v) Filter lubricant oil bypass - 02 Nos g) DG Set shall be supplied alongwith acoustic enclosure of the manufacturer suitable for 82.5 KVA DG set as per CPCB norms. Notes: The quoted rates shall be deemed to include cost of following :- (i) Capacity of alternator at 2750 M altitude AC 3 Phase 415 Volts 50 Hz and as recommended by the manufacturer for above sized DG set. (ii) PCC platform as per manufacturer design (iii) Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep/authorised agent/sister concern etc. (iv) Engine shall designed keeping in consideration of de rating factor for 2750 M altitude. (vi) Contractor shall produced a copy of approved cerrtificate to authinticate the above from the OEM/DE.
83Notes:- The quoted rates shall be deemed to include cost of following:- (i) Capacity of alternator at 2750 meters altitute 82.5 KVA, AC 3 Phase, 415 volts, 50 Hz. and as recommended by the manufacturer for above sized DG set . (ii)PCC Platform as per manufacter design . (iii) Engine and alternator shall be assembled on common steel frame by the manufacturer itself and not by rep / authorised agent / sister concern etc. (iv)Engine shall be designed keeping in consideration of de-rating factor for 2750 meters altitute. (v)Installation, testing and commissioning of Gen Set shall be done in presence of maufacturer"s Engineer and not by any authorised person. (vi)DG Set to be tested for 12 Hrs contineously as following. All testing materials and fuel to be provided by the contractor. No Load = 15 Minutes, 25% of Rated load = 30 Minutes, 50% of Rated load = 30 Minutes, 75% of Rated load = 30 Minutes, Full load = 4 Hr, 110% on Rated Load = 30 Minutes, Full load = 4 Hr, 75% of Rated load = 30 Minutes, 50% of Rated load = 30 Minutes, 25% of Rated load = 30 Minutes, No Load = 15 Minutes. (vii) Contractor shall produced a copy of approved certificate to authenticate the above from the OEM/DE
84CENTRAL HEATING SYSTEM WORKS (SCHEDULE "A" PART-XVI)
85Design, Supply, installation , commissioning and testing of Central Heating Plant using oil fired Glycol based Hot water generator (Kerosene/ HSD oil as fuel) suitable for operation at 50Hz, Three phase 4 wire, 433/230 volts, AC Supply, complete for maintaining the temperature inside the building at 20°C± 2°C during winter for the buildings at S No 3.01 of BOQ (Schedule "A" Part-I Section-I). The temperature should be maintained atHAWS Gulmarg as per the data sheet given in Particular Specifications at ambient temperature upto the (-)18°C at the height of 2750 mtr above MSL .
86CHS Plant should comprise of boilers (2 Working + 1 Stand by), glycol solution circulation centrifugal pumps (1 Working + 1 Stand by), glycol solution make up centrifugal pumps (1 Working + 1 Stand by), flue gas exhaust pipe connected to chimney as per CPCB norms (01 Nos with Each Boiler), expansion tank, glycol fluid tank, underground bulk oil storage tank (not less than 10 KL ), day oil storage tank (not less than 990 Ltrs), transfer gear oil pumps Kerocine oil (1 Working + 1 Stand by), Kerosene/HSD oil piping of suitable size with necessary accessories, hot glycol fluid piping of suitable size with suitable insulation and necessary accrssoires, suitable valves, Wall mounted FCUs with remote control, Wall mounted Towel Radiators in each toilets, 1st fill of glycol charge (The mixture of water and glycol shall have freezing temperature of -25 deg C), LT Panel with necessary safety control system with all accessoires including all necessory electric connection with the equipment (Cables shall run in Cable tray of suitable size), danger notice plate, “ No Smoking " and “ Flammable” sign board as per requirement of Petroleum Rules and CCOE Nagpur and all other necessary items for OTM Accn 140 ORs. Note : All the equipment & accessories should be as per appropriate codel provisions.
87Notes :The rates quoted by the tenderer for the work deemed to include the provision of following :- (i)PCC/RCC foundation for Chimney, Pumps, Boilers, Tanks and other equipments as specified by the OEM. (ii) Submission of whole scheme of CHS including Boiler and pumps capacity design, FCUs capacity design, piping design from plant to the rooms for circulation of Glycol mixture and technical specification duly vetted by IIT (not by professor in his individual capacity) within 90 days form date of commencement of work for approval of Accepting Officer. The invoice of the payment made to institute for vetting the whole scheme to be submitted to the Department. (iii) All the Electric Panels should be as per suitable ingress portection Code and CPRI approved. All the equipment & accessories should be as per appropriate codal provisions. (iv) All the miscellenous and other items, if any required, as per OEM"s Design.
88Schedule "A" Part-XVII (Manning and Operation During Defect Liability Period )
89Outsourcing of servicesfor manning and operationof Central Heating Plantconsisting of Glycole mixture based Hot water generater, pumps, day oil & bulk oil tank, glycol make up tank, piping, control paneland all other connected items at HAWS Gulmarg for 1st year after completion of Phase-II during defect liability period by deploying 1 No trained Operator per shift (each shift of 08 Hours) (One Operator per Plant per Shift for one plant) in three shifts per day including Sundays and holidays complete all as specified anddirected by Engineer-in-charge . Notes: 1.Operator will operate the plant and ensure proper functioning. 2. Maintain a record of hours run of each Plantin a appropriate log sheet on daily basis . 3. The operator will not leave the duty place without permission . 4 . Any minor repairs required will be done after informing the department. 5. Outsourcing staff will change after every 11 months. 6. The Qualification of Operator shall be ITI passed cerificate having minimum 03 years practical experience.
90Outsourcing of servicesfor manning and operationof Central Heating Plant consisting of Glycole mixture based Hot water generater, pumps, day oil & bulk oil tank, glycol make up tank, piping, control paneland all other connected items at HAWS Gulmarg for 2nd year after completion of Phase-II during defect liability period by deploying 1 No trainedOperator per shift (each shift of 08 Hours) (One Operator per Plant per Shift for one plant) in three shifts per day including Sundays and holidays complete all as specified anddirected by Engineer-in-charge . Notes: 1.Operators will operate the plants and ensure proper functioning. 2. Maintain a record of hours run of each Plantin a appropriate log sheet on daily basis . 3. The operator will not leave the duty place without permission . 4 . Any minor repairs required will be done after informing the department. 5. Outsourcing staff will change after every 11 months. 6. The Qualification of Operator shall be ITI passed cerificate having minimum 03 years practical experience.