Turnkey Works For Ct Simulator At D-Block, Crc, Actrec - Brickwork Breaking: Demolishing Existing Damaged / Cracked Brickmasonry With Cement Mortar And Plaster At All Floors And Levels Including Scaffolding Stacking Of Serviceable Materials Without Damaging The Adjacent Masonry / Rcc Structure Sanitary Fittings & Fixtures And Disposal Of Unserviceable Material Carting Away The Debris Out Of Hospital Premises Complete All As Directed By The Engineer-In-Charge. 3 Dismantling Stone Slab Flooring Laid In Cement Mortar Includingstacking Of Serviceable Material And Disposal Of Unserviceable Materiaout Of Actrec Campus 4 Debris Removing:Removal Of Debris / Murrum / Stones Etc. From Actrec.Premises Including Clearing The Site / Sweeping Complete, Carting Away All Materials Out Of The Hospital Premisesas Specified & Directed.Single Capacity Truck 5 Dismantling Aluminium / Gypsum Partitions, Doors, Windows, Fixed Glazing And False Ceiling Including Disposal Of Unserviceable Material And Stacking Of Serviceable Material Out Of Actreccampuslead And Lift As Directed By Engineer-In-Charge. 6 Dismantling Doors, Windows And Clerestory Windows ( Steel Or Wood ) Shutter Including Chowkhats, Architrave, Holdfasts Etc. Complete And Stacking And Disposing Unservisiable Material Out Of Actrec Campus. 7 Brick Masonary With Bricks With Compresive Strengnth In Cement Morter 1: 6 Using Crusued Sand, In Walls, Trenches Etc Inclding Scafolding, Curing Etc Complete As Directed & Instructed 8 Cement Plastering: Cement Plastering For Internal Wall And Ceiling With Cement Mortar 1:4Including Hacking The Concrete Surfaces, , Racking Out Brick Work Joints At All Floors And Levels In Quantities As Required At Site Including Scaffolding Curing, Etc. Complete All As Directed By Engineer-In-Charge. 9 Waterproofing Cable Trench: Providing And Applying Integral Crystalline Slurry Of Hydrophilic Innature For Waterproofing Treatment To The Rcc Structures Like Retaining Walls Of The Basement, Water Tanks, Roof Slabs, Podiums, Reservior, Sewage & Water Treatment Plant, Tunnels / Subway And Bridge Deck Etc., Prepared By Mixing In The Ratio Of 5 : 2 ( 5 Parts Integral Crystalline Slurry : 2 Parts Water ) For Vertical Surfaces And 3 : 1 ( 3 Parts Integral Crystalline Slurry : 1 Part Water ) For Horizontal Surfaces And Applying The Same From Negative ( Internal ) Side With The Help Of Synthetic Fiber Brush. The Material Shall Meet The Requirements As Specified In Aci-212-3R-2010 I.E By Reducing Permeability Of Concrete By More Than 90% Compared With Control Concrete As Per Din 1048 And Resistant To 16 Bar Hydrostatic Pressure On Negative Side. The Crystalline Slurry Shall Be Capable Of Self-Healing Of Cracks Up To A Width Of 0.50Mm. The Work Shall Be Carried Out All Complete As Per Specification And The Direction Of The Engineer-In-Charge. Note: The Work Shall Be Executed Through Authorized Company Certified Applicator. 10 Providing And Laying Vitrified Floor Tiles & In Skirtingin 600 X 600 Sizes ( Thickness To Be Specified By The Manufacturer ) With Water Absorption Less Than 0.08% And Conforming To Is: 15622, Of Approved Make, In All Colours And Shades, Laid On Minimm20mm Thick Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) , Jointing With Matching Cement Slurry @ 3.3 Kg / Sqm Including Grouting The Joints With White Cement And Matching Pigments Etc., Complete As Directed And Instructed.Sample Shall Be Got Approved Before Procrument. 11 Providing And Laying Polished Granite Stone Flooring In Required Design And Patterns, In Linear As Well As Curvilinear Portions Of The Building All Complete As Per The Architectural Drawings With 18 Mm Thick Stone Slab Over 20 Mm ( Average ) Thick Base Of Cement Mortar 1:4 ( 1 Cement : 4 Coarse Sand ) Laid And Jointed With Cement Slurry And Pointing With White Cement Slurry Admixed With Pigment Of Matching Shade Including Rubbing, Curing And Polishing Etc. All Complete As Specified And As Directed By The Engineer-In-Charge. Sample Shall Be Got Approved Before Procrument. 12 Providing And Laying In Position Cement Concrete Of M-25 Gradeincluding The Cost Of Centering And Shuttering If Reuqired In Filling Up The Foundation Etc Including Curing Complete As Directed And Instructed. 13 Providing And Applying White Cement Based Putty Of Average Thickness 2 Mm Or More, With Preparing Ans Applying As Per Manufacturer Specification, Over The Plastered Wall Surface To Prepare The Surface Even And Smooth Complete. 14 Providing & Applying Luster Painttwo Or More Coatsof Primer & Thereafter Two Coats Of Paint To The Required Colour Scheme And As Per Manufacturers Instructions / Specificationsto The Walls, Beams, Columns, Ceilings, Partitions Doors Etc. Including Thoroughly Scrapping The Existing Surface With Sand Papers, Removing Old Paint, Filling Up Crevices And Levelling With Waterproofputty / Plaster Of Paris Of Necessary To Obtain Smooth Surface Etc. Complete Job Including Removal Of Stains, Painting Spots On Floors, Aluminium Window Frame & Glassetc Asto The Entire Satisfaction Of Engineer In Charge 15 Finishing Walls With Acrylic Smooth Exterior Paint Of Required Shade Two Or More Coat And Including Priming Coat Of Exterior Primer Applied Complete As Directed And Instructed 16 Painting With Synthetic Enamel Paint Of Approved Brand Andmanufacture To Give An Even Shade Two Or More Coats On New Work With A Cost Of Primer On Wood & Metal Surfaces. 17 Providing & Fixing Aluminum Powder Coated Metal Tiled False Ceilingwith Proper Alignment Including Fixing Of New Grid Supports At Necessary Locations As Per Manufacturers Specification Complete As Directed And Instructed.Sample Shall Be Got Approved Before Procrument. 18 Carpentry Work 19 Providing And Fixinglow Ht. / Full Ht. / Over Headstorage. They Shall Consist Of 18Mm Thick Marine Plytop, 18Mm Thick Commercial Ply Sides & Base, 6Mm Thick Commercial Ply Back, 12Mm Thick Commercial Ply Intermediate Shelf. The Shutters Should Be Partly Glazed, Made Out Of 12Mm Thick Commercial Ply. The Drawers Shall Be Consist Of 12Mm Thick Commercial Ply. All Inner Surfaces Including Shutters, Shelf Top & Bottom Shall Be Finished With 1Mm Thick White Laminate. All Outer Surfaces Shall Be Finished With 1Mm Thick Laminate Of Approved Shade. Inclusive Of Handles, Lock, Tower Bolt And Magnet Locks Etc. Complete. 20 Gantry Room ( Mould, Cushions ) 21 Change Room 22 Overhead Storage 23 Providing And Fixing A Desk Consist Of 20Mm Thick Commercial Ply Top Supported On 18Mm Thick Commercial Ply Verticals And Base, 18Mm Thick Commercial Ply Back. The Top Shall Be Finished With 1Mm Thk. Laminate. All The Inner Surfaces Shall Be Finished With 1Mm Thick White Laminate. One Drawer Unit And & One No. Of File Cabinet Shall Be Provided On One Side. Height Of Drawers Shall Be 150Mm. Drawer Shall Be Consist Of 12Mm Thick Commercial.The Rate Should Be Inclusive Of Handles, Lock, Tower Bolt And Magnet Locks Etc. Complete. Refer To The Drawing For Details. 24 Providing And Making Counter For Working With Granite Topwith Neseccery Hardware Complited With Storage Below 25 Providing And Making Console Table With Storage Below 26 Providing & Fixing 1St Class Teak Wood In Door Frame With Finished Size Of Of 5 X 4 Size And & Architirive Around Frame Of 3X 1 / 2For Required Door Opening. Single Leaf Door ( 3Ft X 7Ft Htx 3No.. ) Double Leaf Door ( 4Ft X 7Ft Ht.X 1 No ) Double Leaf Door ( 5Ft X 7Ft Ht.X 2Nos ) Including Hold Fast 6 Nos Per Frame Including Fising In Positon With Concrete To Line Level Etc Complete As Directed And Instructed. The Frame Touching The Brick / Plaster Surface Shall Be Finished With 2 Coat Of Bitenemous Primer. 27 Providing And Fixing Approved Quality Solid Core Flush Door Insingle / Double Leaf 40Mm Thick Bwr Type Plywood Surface On Both Sides, Lined With 2Mm Lead Sheet The Lead Sheet To Be Fixed On Door Frame Too Have Seamless Barrier, And Laminated With 1.5 Mm Thick Water Proof Laminate Of Approved Make And Shade, Twbidding On All Edges , Doors To Beof Exterior Grade. 28 Providing And Fixing Approved Solid Core Flush Door Insingle / Double Leaf 40Mm Thick Bwr Type Plywood Surface On Both Sides And Laminated With 1.5 Mm Thick Water Proof Laminate Of Approved Make And Shade, Twbidding On All Edges , Doors To Beof Exterior Grade. Single Leaf Door ( 3Ft X 7Ft Ht.. ) Double Leaf Door ( 4Ft X 7Ft Ht. ) 29 Providing & Fixing Wall Panelling Over Wood Frame Work Of 2 X 2 Grid With Teak Wood Of 2X2 Finished With 6Mm Thick Commercial Ply And Finished Ithe Approved Laminate In Design. 30 Providing And Fixingbeveled Edge Mirror Of Required Size & Shape Superior Glass ( Of Approved Quality ) Complete With 6 Mm Thick Hard Board Ground Fixed To Wooden Cleats With C.P. Brass Screws And Washers Complete. 31 Providing And Fixing Roller Blinds To Window As Per Requirment 32 Providing And Supllying Low Back Staff Chairs Godrej Make 33 Supply & Fixing Of Lead Glass 1 Sqft ( Viewing Panel In Door ) 34 Trap Door In Acp With 25Mm Aluminium Angle For Framing And Supporting 35 Electrical & Networking Works 36 Point Wiring With 2-1.5 Sq.Mm. Pvc Copper Wire 1100 V Grade In Rigid Pvc Conduit 25 / 20 Mmdiawith Pvc Accessories Junction Boxaid In Wall With Legrandmakeswitch, Socket, Box & Plates 37 Supply&Erectionofmainswithpvccopperwire ( Make - Finolex Or Polycab ) 1.1Kvgradeinconcealedpvc Conduitpipe. ( Make - Precision Or Diamond ) 38 2 Wires * 6 Sqmmwithearthing For Ac 39 2 Wires *4 Sqmmwithearthing 40 2 Wires*2.5 Sqmmwithearthing 41 Supply / Erection Of 5 / 15A 250 V 6 Pin Shuttered Multi Socket & 16 A Switch Withindictor Modular With Plate Erected With Box. 42 Copper Earthplatesize600*600*3Mmwith 2 Nos Of 25 *3 Mm Copper Strip Inspecificallypreparedearthpit1.5Mtrbelowgroundlevelwith40kgcharcoal&Saltwith19mmdiagipipe, Funnelwithwiremeshforwatering&Bricksmesoneryblock, Cicover Complete Asper Is 3043. 43 Supply & Laying Of 25*3 Mm Copper Strip For Earthing 44 Supply & Fixing Of 600*6002*36 W Led Light Fixture. 45 Supply & Fixing Ofelectrical Panel As Per Sld. 46 Supply & Fixing Of 315A Tpn Mccb With Enclosure 47 Supply & Fixing Of 250A Tpn Mccb With Enclosure 48 Supply & Fixing Of Radiation Lamp 49 Supply & Fixing Of Emergency Switch 50 Supply & Fixing Of On / Off Switch 51 Supply & Laying Of 185 Sqmm *3.5 Sqmm Allu Cable With Excavation Or Saddle On Wall 52 Termination Of Above Cable 53 Supply & Laying Of 70 Sqmm Copper Flexible Cable 54 Bio-Metric Access Control For Main Entry Door. 55 Networking Work 56 Providing Rj 45 Connector And Crimping At The Respective Points With Box, Face Plate. 57 Supply & Laying Of Cat-6 Computer Cable 58 Supply & Fixing Of 24 Port Switch With Patch Panel , Rack Complete With Connections 59 Telephone Hand Set Bitel Or Equivalent Make 60 Telephone Cable 5 Pairsupply And Laying 61 Telephone Cable Termination With Crone Box, Socket 62 Supply And Laying Of Conduit For Cabling 63 2 Mtr Patch Cord 64 3 Mtr Patch Cord 65 Fire Alram System 66 Addressablesmoke Detector 67 Conventional Hotter With Flasher 68 Termination And Configeration At Existing Fire Panel 69 Supply & Laying Of 2X1.5 Sqmm Copper Cable Armoured 70 Response Indicator 71 Fire Extinguisher 5Kg 72 Hvac Work 73 Air Cooled Ductable Units: Supply & Installation, Testing And Commissioning Of Ceiling Suspended Air Cooled Ductable Split Units Having Capacity 8.5 Tr With Scroll Compressor. The Indoor Unit Shall Comprise Of Fan, Cooling Coil, Filter And Expansion Device.The Outdoor Unit Shall Comprise Of Hermetic Scroll Compressors.Air Cooled Condenser & Condenser Fan.If Multiple Compressors Are Offered, They Shall Have Independent Refrigerant Circuits.Also, Compressor Shall Be Cut-Off Automatically Under Part Load Conditions.The Units Shall Have Microprocessor Controls.Scope Shall Have Include All Supports And Mounting Frame For The Indoor And Outdoor Units And Connect The Indoor Door With The Ducts With Volume Control Dampers As Required And Minor Modification Of Ducts If Any Required For Installation.The Units Shall Be Selected For Ambient Conditions As Specified.The Units Shall Be Factory Assembled And Only The Refrigerant Piping Carried Out At Site. The Contractor Shall Arrange To Provide Suitable Arrangement To Grout On The Wall / Floor.The Rate To Include Is All Respect Including Refrigerant Charging, Oil, All Hardware’S, Drain Pipes Of Suitable Size, Welding, Inter Connecting Cables, Mounting Frame / M.S Stand For Indoor And Outdoor Unit Etc. For Commissioning The System. ( Cost Of Copper Piping Shall Not Include And Will Be Paid As Per Actual ) . Eco Friendly Refrigerant Shall Be Considered.Make: Daikin / Trane / Carrier 74 Supply & Installation Of Refrigerant Piping:All Refrigerant Piping Shall Be Of Copper, Complete With Supports Between Indoor & Outdoor Units Duly Insulated With 13Mm Nitrile Rubber With Gc Cloth Insulation.Rmt Indicated Is For Set Of Piping Between Indoor And Outdoor Machine, ( Individual Piping Will Not Be Measured ] All Exposed Cable, Pipingshould Be Laid In Ladder / Perforated Type Tray With Enclosure. Make: Mehta, Mandev Tube, Rajco. 75 11 / 8 , 1 / 2 Or Equivalent To The Unit 76 Sitc Pvc Drain Pipe Having Pressure Holding Of 6Kg / Cm2drain Piping Complete With All Accessories With 12Mm Nitrile Rubber Insulation. Make: Prince, Supreme, Kisan. 77 Dia 32Mm 78 Sitc Of Power / Control Cables Between Indoor And Outdoor Unit. All Cable Should Be Laid In Gi Tray. Finolex / Polycab / Rr Kabel 79 Gi Duct: Supply, Installation, Balancing And Commissioning Of Factory Fabricated Gss Sheet Metal Rectangular / Round Ducting Complete With Neoprene Rubber Gaskets, Elbows, Splitter Dampers, Vanes, Hangers, Supports Etc. As Per Approved Drawings And Specifications And As Per Smcna Standard Of Following Sheet Thickness Complete As Required.Make: Tata, Jindal, Sail. 80 Thickness 0.63 Mm Sheet ( 24 Swg ) 81 Thickness 0.80 Mm Sheet ( 22 Swg ) 82 Supplying And Fixing Of Following Thickness Duly Laminated Aluminum Foil Of Mat Finish Closed Cell Nitrile Rubber ( Class O ) Insulation On Existing Duct After Applying Suitable Adhesive For Nitrile Rubber. The Joints Shall Be Sealed With 50 Mm Wide And 3 Mm Thick Self Adhesive Nitrile Rubber Tape Insulation Complete As Per Specifications And As Required. Make: K-Flex, Armaflex, Armacell. 83 13 Mm 84 Supplying And Fixing Of Following Thicknessopen Cellaccoustic Nitrile Rubber ( Class O ) Insulation On Existing Duct ( Inside / Outside ) After Applying Suitable Adhesive For Nitrile Rubber And Fixing With All Necessary Hardware And Supports Complete As Per Specifications And As Required And As Instructed And As Directed By Oic-Es. Make: K-Flex, Armaflex, Armacell. 85 25 Mm 86 Supply, Installation, Testing And Commissioning Of Gi Volume Control Duct Damper / Non Return Damper 18 Guage Gi. Frame & 20 Guage Gi Blades Complete With Neoprene Rubber Gaskets, Nuts, Bolts, Screws Linkages, Flanges Etc, As Per Specifications. Make: Greenheck / Ruskin Titus / Trox / Cosmos 87 Supplying, Fixing, Testing And Commissioning Of Fire Dampers In Supply Air Duct / Main Branch And Return Air Path As And Where Required Of Required Sizes I / C Control Wiring, The Damper Shall Be Motorized And Spring Return So As To Close The Damper In The Event Of Power Failure Automatically And Open The Same In Case Of Power Being Restored. The Spring Return Action Shall Be Inbuilt Mechanism And Not Externally Mounted. The Damper Shall Also Be Closed In The Event Of Fire Signal Complete As Required And As Per Specifications. Make: Greenheck / Ruskin Titus / Trox / Cosmos. 88 Sitc Of Actuator For Fire Damper Ul Listed. Make: Belimo, Honeywell, Siemens. 89 Supplying & Fixing Of Powder Coated Extruded Aluminium Supply / Return Air Grills With Louvers But Without Volume Control Dampers Complete As Required. Make: Air-Product / Cosmos / Greenheck. 90 Aluminium Extruded Opposed Blade Collar Dampers. Make: Air-Product / Cosmos / Greenheck. 91 Supply & Fixing Of Fire Retardant Synthetic Canvass Connection With A Provision To Measure The Canvass Temperature At The Mouth Of Package Units & Plenum With All Fixing Arrangement, Nut Bolts, Hardware’S Etc. As Directed For Above Package Units. 92 Dismantling Of Existing Duct, Grill, Diffuser, Split Acs Etc And Instllation Of Existing Split Units Including Gas Charging And Commissioning As Instructed And As Directed By Oic-Es. 93 Sitc Of Dehumidifier Of 35L / Day Capacity. Make- White Westing, Origin, Amfah