Public Administrative Department Local Bodies Closing in 0 days TDR #34031230

Construction Of Car Parkingat Satpulidistt-Pauri Garhwal

Issued by Local Bodies · satpuli, Uttarakhand
Tender Value
3.15 Crore
Estimated cost
Bid Submission
12 Oct 2022
0 days left
EMD
6.30 Lakhs
Bank guarantee accepted
Document Fee
4720
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
satpuli → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction Of Car Parkingat Satpulidistt-Pauri Garhwal

BOQ

Name of Work: CONSTRUCTION OF CAR PARKINGAT SATPULIDISTT-PAURI GARHWAL
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic Excavat in foundation trenches or drains (not exceeding 1.5 m in width or 1 including dressing of sides and ramming of bottoms, lift upto 1.5out the excavated soil and disposal of surplus excavated soil as dir of 50 m. All kinds of soil.
2Providing and laying in position cement concrete of specified gradeexcluding the cost of centring and shuttering. All work upto plinth level. 1:4:8(1Cement:4coarsesand:8gradedstone aggregate 40 mm nominal size).
3SupplyingandfillinginplinthwithJamunasandunderfloorsincluding, watering, ramming consolidating and dressing complete.
4Treatment of soil under existing floors using chemical emulsion @one litre per hole, 300 mm apart including drilling 12 mm diameter holes andplugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match theexisting floor with Chlorpyriphos/ Lindane E.C. 20% with 1%.
5Brick work with F.P.S. bricks of class designation 75 in foundationand plinth in Cement mortar 1:6 ( 1 cement : 6 coarse sand )
6Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shape and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
7Half brick masonry with F.P.S. bricks of class designation 75 insuperstructure above plinth level upto floor V level in cement mortar 1:4 (1cement : 4 coarse sand)
8Providing and laying in position specified grade of reinforcedcement concrete excluding the cost of centring, shuttering,finishing and reinforcement - All work upto plinth level in 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
9Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses,fillets, columns, pillars, piers,abutments, posts and struts etc. uptofloor five level excluding cost of centring, shuttering, finishing and reinforcement in1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
10Reinforcement for R.C.C. work including straightening, cutting,bending, placing in position and binding all complete. Thermo-Mechanically Treated bars. As per BBS
11Centring and shuttering including strutting,ropping etc. andremoval of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers.
12Centring and shuttering including strutting,ropping etc. andremoval of form for Centring and Shuttering for Suspendedfloors,roofs,landings, balconies and access platform.
13Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface.Fixing with adjustable lugs with split end tail to each jamb
14Providing and fixing pressed steel door frames confirming to IS: 43 from commercial mild steel sheet of 1.25 mm thickness including h jamb, bead and if required angle threshold of mild steel angle of se or base ties of 1.25mm pressed mild steel welded or rigidly fixed t mechanical means, adjustable lugs with split end tail to each jambbutt hinges 2.5mm thick with mortar guards, lock strike-plate andas specified and applying a coat of approved steel primer after pre surface as directed by Engineer-in-charge. Profile B
15Steel work welded in built up section/framed work including cutting in position and applying a priming coat of approved steel primer us required. Ingratings,frames,guardbar,ladder,railings,brackets,gates and similar works.
1612 mm cement plaster of mix in 1:6 (1 cement : 6 fine sand)
176 mm cement plaster of mix in 1:3 (1 cement : 3 fine sand)
18Providingandlayingintegral cement based waterproofing treat includingpreparationofsurfaceasrequiredfortreatmentof balconies,terracesetc consisting of following operations: a) Appl aslurrycoatof neat cementusing2.75kg/sqm. ofcement ad with water proofing compoundconformingto IS. 2645 andappro byEngineer-in-chargeovertheRCCslabincludingadjoining upto 300mm heightincludingcleaning the surfacebefore treatm b) Laying brick bats with mortar using broken bricks/brick bats 25to 115mm sizewith50% of cementmortar 1:5(1cement: 5 sand) admixed with water proofing compound conforming to IS : 2 andapprovedbyEngineer-in-chargeover20mmthicklayer cementmortarofmix1:5(1cement:5 coarsesand)admi waterproofingcompoundconformingtoIS:2645 andappro Engineer-in-chargetorequiredslopeandtreatingsimilarlyth walls and slabs c) Aftertwo daysof proper curing applying asec coatofcementslurryusing2.75kg/sqmofcementadmixed waterproofingcompoundconformingtoIS:2645 andappro Engineer-in-charge.d)Finishingthesurfacewith20mmthic jointlesscementmortarofmix1:4(1cement:4coarsesan admixed with waterproofing compoundconformingto IS:264 approvedbyEngineer-in-chargeincludinglayingglassfibrecl approved quality in top layer of plaster and finally finishing the surf withtrowelwithneatcementslurryandmakingpatternof mmsquare3mmdeep.e)Thewholeterracesofinishedsha flooded with water for a minimum period oftwo weeks forcuringfor final test. All above operations to be done in order and as direct and specified by the Engineer-in-Charge : With averagethicknessat khurra as 65 mm
19Providingandapplyingplasterofparisputtyof2mmthickn plastered surface to prepare the surface even and smooth complet
20Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), including finishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design. In 75x75 mm deep chase
21Providing and laying Vitrified tiles in different sizes (thickness to be specified by the manufacturer), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser of steps, laid with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of joints (Payment for grouting of joints to be made separately).Size of Tile 1000x1000 mm
22Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
23Kota stone slab flooring over 20 mm (average) thick base laid overjointedwith grey cement slurry mixed with pigment tomatch theoftheslabincludingrubbingandpolishingcompletewithba cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick.
24Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
25ProvidingandfixingIstqualityceramicglazedwalltilesconf IS : 15622 (thicknessto be specified by the manufacture ) of appr make in all colours, shades except burgundy, bottle green, black ofsizeas approvedbyEngineer-in-Charge inskirting, risersof ste dados over 12 mm thick bed of cement Mortar 1:3 (1 cement : 3 c sand)and jointingwith [email protected] persqmi pointinginwhitecementmixedwithpigmentofmatchingsh complete.
26Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part 1) non-decorative type, core of block board construction with frame o wood and well matched commercial 3 ply veneering with vertical g bands and face veneers on both faces of shutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws.
27Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete.
28Providing and fixing aluminium sliding door bolts ISI marked anodi coating not less than grade AC 10 as per IS : 1868) transparent orcolour or shade with nuts and screws etc. complete. 300x16 mm
29Providing and fixing aluminium handles ISI marked anodised (anod less than grade AC 10 as per IS : 1868) transparent or dyed to req shade with necessary screws etc. complete : 125 mm
30Providing and fixing aluminium tower bolts ISI marked anodised (a not less than grade AC 10 as per IS : 1868 ) transparent or dyed t or shade with necessary screws etc. complete. 250x10 mm
31Providing and fixing aluminium hanging floor door stopper ISImarked anodised (anodic coating not less than grade AC 10 as per IS : 1868)transparent or dyed to required colour and shade with necessary screws etc. complete. Single rubber stopper
32Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade
33Finishing walls with Acrylic Smooth exterior paint of required shade :New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
34PaintingwoodworkwithDeluxeMultiSurfacePaintofrequired shade.Twoor more coat applied @0.90ltr/[email protected]/10sqm ofapproved brand or manufacture
35PaintingSteel workwithDeluxeMultiSurface Paintto givean even shade. Two or morecoatapplied @0.90 ltr/10sqmover an under coatof [email protected]/10sqmofapproved brand or manufacture
36Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows alll complete. With 4.0 mm thick glass panes.
37Windows using galvanised M.S. wire gauge with average width of a in both directions with wire of dia. 0.63 mm. With 12 mm mild steel U beading.
38Providing and fixing Glow studs of size 100x20 mm made of heavy duty body shall be moulded ASA (Acrylic styrene Acryloretrite ) or HIP (High impact polystyrene) or ABS having electronically welded micro- prismatic lens with abrasion resistant coating as approved by Engineer in charge. The glow stud shall support a load of 13635 kg tested in accordance with ASTM D4280. The slope of retro- reflective surface shall be 35 (+/-5) degress to base .The reflective panels on both sides with at least 12 cm of reflective area up each side. Theluminance intensity should be as per the specification and shall be tested as described in ASTM I: 809 as recommended in BS: 873 part 4 : 1973. The studs shall be fixed to the Road surface using the adhesive conforming to IS, as per procedure recommended by the manufacturer complete and as per direction of Engineer-in-charge.
39Manufacturing, supplying and fixing retro reflective sign boards made up of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated type heat activated retro reflective sheeting conforming to type - IV of ASTM-D4956-01 in blue and silver white or other colour combination including subjectmatter, message (bi-lingual), symbols and borders etc. as per IRC ; 67:2001, pastedon substrate by an adhesive backing which shall be activated by applying heat and pressure conforming to class -2 of ASTM-D-4956-01 and fixing the same with
40Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A including jointing with seal ringconforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Singlesocketed pipes. 100 mm diameter
41Providing and fixing on wall face unplasticised Rigid PVC rain waterpipes conforming to IS : 13592 Type A including jointing with seal ringconforming to IS :5382 leaving 10 mm gap for thermal expansion, (i) Singlesocketed pipes. 75 mm diameter
42Providing and fixing M.S. holder bat clamps of approved design toC.I. or S.C.I, rain water pipes embedded in and including cement concrete blocks10x10x 10cm of 1:2:4 mix (1 cement: 2 coarse sand : 4 graded stone aggregate20 mm nominal size) and cost of cutting holes and making good the walls etc.100 mm diameter.
43Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions a
44Providingandfixingwhitevitreouschinapedestaltypewater closet(EuropeantypeW.C.pan)withseatandlid,10litrelow levelwhiteP.V.C.flushingcisternwithmanuallycontrolleddevice(handle lever), conforming
45Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32. White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps
46Providingandfixingwhitevitreouschinapedestalforwashb completely recessed at the back for the reception of pipes and fitting.
47Providing and fixing G.I. pipes complete with G.I. fittings andclamps, including cutting and making good the walls etc. internal work - Exposed onwall 15 mm dia. nominal bore
48Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc. (external work) 15 mm dia. nominal bore
49Providing and fixing G.I. pipes complete with G.I. fittings includingtrenching and refilling etc. (external work) 20 mm dia. nominal bore
50Making connection of G.I. distribution branch with G.I. main offollowing sizes by providing and fixing tee, including cutting and threading the pipeetc. complete. 25 to 40 mm nominal bore
51Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931. 15 mm nominal bore
52Providing and fixing C.P. brass angle valve for basin mixer and geyser approved quality conforming to IS:8931.15 mm nominal bore
53Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls
54Providing and placing on terrace (at all floor levels) polyethylene water tank ISI : 12701 marked with cover and suitable locking arrangement in tank. and necessary holes for inlet, outlet and overflow pipes but without fitting base support for tank.
55Providing and fixing PTMT soap Dish Holder having length of 138m 102mm, height of 75mm with concealed fitting arrangements weig than 106 gms.
56Providing and fixing 600x450 mm bevelled edge mirror of superiorquality) complete with 6 mm thick hard board ground fixed to woo C.P. brass screws and washers complete.
57Providing and fixing PTMT towel rail complete with brackets fixed to wooden. 600mm long towel rail with total length of 645mm, width 78mm and effective height of 88mm, weighing not less than 190gms.
58Providing and fixing uplasticised PVC connection pipe with brass unions. 45 cm length. 15 mm nominal bore.
59Providing and fixing PTMT grating of approved quality and colour.Circular type.100 mm nominal dia.
60Providing and fixing ball valve (brass) of approved quality complete. High or low pressure with plastic floats. 15 mm nominal bore
61Constructing brick masonry manhole in cement mortar 1:4 ( 1cement : 4 coarse Inside size 60x45x50 cm. inside including C.I. cover withframe (light duty) 455x610 mm internal dimensions total weight of cover and frameto be not less than 38 kg (weight
62Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, disposed earth to be levelled and neatly dressed.Excavation in all kinds of soil
63Providing and laying in position machine batched, machine mixed and machine vibrated design mix cement concrete of specified grade for reinforced cement concrete work including pumping of concrete to site of laying but excluding the cost of centering,shuttering, finishing and reinforcement. including Admixture in recommended proportions as per IS 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge M-25 grade reinforced cement concrete by using 410.0 kg of cement per cu.m of concrete. All work upto floor V level.
64Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete.Thermo-Mechanically Treated bars.
6515 mm cement plaster on rough side of single or half brick wall of mix - 1: 6 (1 cement: 6 fine sand)
66Supplying and fixing C.I. cover with frame for manholes : 455x610 mm rectangular C.I. cover (light duty)the weight of the cover to be not
67Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.40mm thick with 20mm nominal size stone aggregate.
68WGPVCPT Point wiring in PVC conduit, with piano type switch: wiring for light point / fan point /Ex Fan Point/Call Bell Point recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required. Group C
69LPACCPT S / F light plug point piano type accessories: Supplying and fixing metal box of 150 mm x 75 mm x 60 mm deep(nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 anos socket outlet and 5/6 amps piano type switch, connection, painting etc. as required.( For light plugs to be used in non residential buildings).
70WGSTLPTTC Twin controlPoint wiring in PVC conduit, with piano type switch: wiring for twin control light point recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq. mm FR PVC insulated copper conductor single core cable etc. as required.
71PPACCPT S/F power plug point piano type accessories: Supplying and fixing matel box of 180 mm x 100 mm x 60 mm deep on surface or in recess with 15 Amp piano type switch and socket. Complete with all work
72MCBDPSOC20 S/F 20A SPN MCB industrial socket outlet: Supplying and fixing 20amps, 240 volts, SPN industrial type, socket outlet, with 2 pole
73WGPVCSB Circuit/sub-man wiring in PVC conduit:Wiring for circuit/ submain wiring along with earth wire with the following size of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 1.5 sq. mm + 1 x 1.5 sq mm earth wire.
74WGPVCSB Circuit/sub-man wiring in PVC conduit:Wiring for circuit/ submain wiring along with earth wire with the following size of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 2 x 2.5 sq. mm + 1 x 2.5 sq mm earth wire.
75WGPVCSB Circuit/sub-man wiring in PVC conduit:Wiring for circuit/ submain wiring along with earth wire with the following size of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required. 4 x 2.5 sq. mm + 2 x 2.5 sq mm earth wire.
76CREB S / F Ceiling rose : Supplying and fixing 3 pin 5amp ceiling roseincluding connection etc. as required.
77Supplying and fixing PVC batten/ angle holder including connections etc. as required.
78EARGIPL GI earth plate electrode:Earthing with GI earth plate 600x600x6 mm thick i/c accessories and providing masonary encloser with cover plate having locking arrengement and watering pipe etc complete work
79EARGIWRPIP P/F of 6 SWGGI earth wire in pipe Providing and laying earth connection from earth electrode with 6 SWG GI wire in 15 mm diaGI pipe complete work
80TPMCBDB S/F TP MCB DB:4 way (4 +12), Double door, hotizontal type
81MCBC S/FC series SP MCB S/F5 amo 32 amp rating,240V C series MCB on existing DB complete with connections.
82MCBTPISS/F TP MCB isolator : S/F100 amprating ,415V isolatoron existing DB complete with connections.
83S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16S.W.G. M.S. sheet incorporating 10mm dia. M.S. bar round and duly painted with red oxide along with all work
84Eraction testing of Exhaust fan complete with all work
85Eraction testing of ceiling fan etc excludingsupply of down rod complete in all respect
86P/Fixing T5 LED Tube light complete in all respect.

AI Tender Summary

OUR REF NO 34031230
AUTHORITY Local Bodies
TENDER VALUE 3.15 Crore
LAST DATE 12-10-2022
Authority
Authority Name Garhwal Mandal Vikas Nigam Limited
Work Description Construction Of Car Parkingat Satpulidistt-Pauri Garhwal
Basic Detail
Tender No 543/ dated/15.09.2022.
Bidding Type Tender
Location
City satpuli
State Uttarakhand
Key Dates
Publish Date 20 Sep 2022
Submission Date 12 Oct 2022
Open Date 12 Oct 2022
Finance
Tender Value 3.15 Crore
Tender Fee 4720
EMD 6.30 Lakhs
Exemption Not Available
Document List
6710954a-a41d-4e4c-8970-4f94cf96a2fb.html
BOQ_59108.xls
sbd45.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 20, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 12, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 12, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

6710954a-a41d-4e4c-8970-4f94cf96a2fb.html

xls

BOQ_59108.xls

pdf

sbd45.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders