}

Provision Of Otm Accn For 47 Men At Sonamarg -2 Lumpsum / Other Pre-Priced Provisional Schedules Of Works 3 Lump Sum Price Worked Out By The Contractor For Building Works As Listed In Schedule A Part-I Brought Forward From Serial Page No. 29 4 Lum, Srinagar-Jammu And Kashmir

Military Engineer Services-MES has published Provision Of Otm Accn For 47 Men At Sonamarg -2 Lumpsum / Other Pre-Priced Provisional Schedules Of Works 3 Lump Sum Price Worked Out By The Contractor For Building Works As Listed In Schedule A Part-I Brought Forward From Serial Page No. 29 4 Lum. Submission Date for this Tender is 28-11-2022. Uniform Tenders in Srinagar Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

34030868
Corrigendum : Provision Of Otm Accn For 47 Men At Sonamarg -2 Lumpsum / Other Pre-Priced Provisional Schedules Of Works 3 Lump Sum Price Worked Out By The Contractor For Building Works As Listed In Schedule A Part-I Brought Forward From Serial Page No. 29 4 Lum
Open Tender
Indian
Jammu And Kashmir
Srinagar
28-11-2022

Tender Details

Provision Of Otm Accn For 47 Men At Sonamarg -2 Lumpsum / Other Pre-Priced Provisional Schedules Of Works 3 Lump Sum Price Worked Out By The Contractor For Building Works As Listed In Schedule A Part-I Brought Forward From Serial Page No. 29 4 Lump Sum Price Worked Out By The Contractor For Internal Electrification Works As Listed In Schedule A Part-Ii Brought Forward From Serial Page No. 31 5 Lump Sum Price Worked Out By The Contractor For Internal Water Supply Works As Listed In Schedule A Part-Iii Brought Forward From Serial Page No. 34 6 Lump Sum Price Worked Out By The Contractor For Sewage Disposal Works Listed In Schedule A Part-Iv Brought Forward From Serial Page No. 36 7 Lump Sum Price Worked Out By The Contractor For Path Worksas Listed In Schedule A Part-V Brought Forward From Serial Page No. 37 8 Lump Sum Price Worked Out By The Contractor For Area Drainage Works As Listed In Schedule A Part-Vi Brought Forward From Serial Page No. 39 9 Lump Sum Price Worked Out By The Contractor For Hot Water Supply Worksas Listed In Schedule A Part-Vii Brought Forward From Serial Page No. 42 10 Lump Sum Price Worked Out By The Contractor For Protective / Retaining Wall Worksas Listed In Schedule A Part-Viii Brought Forward From Serial Page No. 44 11 Lump Sum Price Worked Out By The Contractor For External Electrification Works As Listed In Schedule A Part-Ix Brought Forward From Serial Page No. 50 12 Lump Sum Price Worked Out By The Contractor For External Water Supplyworks As Listed In Schedule A Part-X Brought Forward From Serial Page No. 52 13 Lump Sum Price Worked Out By The Contractor For Site Clearance & Earthworks As Listed In Schedule A Part-Xi Brought Forward From Serial Page No. 53 14 Miscellaneous Items Of Works ( Schedule A Part-Xii ) Internal Electrification Works 15 Material And Labour For Point Wiring Complete Withpvc Insulated Unsheathed 1100 Volt Grade Frls Cable With Multi Stranded Copper Conductor Of Size 1.5 Sq Mm ( Nominal Area ) Drawn Through And Including Pvc Conduit ( Medium Duty ) Of Suitable Size ( As Per Conductor Run ) With All Fittings And Accessories Concealed In Wall And Ceiling Portion Inculding Concealed Sunk In Pressed Steel Terminal Bozes Of Not Less Than 2Mm Thick Required Size Factory Made And Painted With Synthetic Enamel Paint Black Paint With And Including Top Cover 3Mm Thick Plastic Laminated Sheet ( Make : Hylum ) Of Required Colour Fixed With Brass Screws And Cup Washers With And Including 1.5 Sqmm Frls Multi Stranded Copper Conductor As Continuous Earth Wire Drawn In Same Concealed Conduit, Connected To Main Earth And Earth Dolly Including Cutting Chases And Making Good As Per Existing Specification For One Light / Fan / Exhaust Fan Point Controlled By One, One Way Switch 5Amp Complete All As Specified And Directed. 16 Material And Labour For Point Wiring Complete Withpvc Insulated Unsheathed 1100 Volt Grade Frls Cable With Multi Stranded Copper Conductor Of Size 1.5 Sq Mm ( Nominal Area ) Drawn Through And Including Pvc Conduit ( Medium Duty ) Of Suitable Size ( As Per Conductor Run ) With All Fittings And Accessories Concealed In Wall And Ceiling Portion Inculding Concealed Sunk In Pressed Steel Terminal Bozes Of Not Less Than 2Mm Thick Required Size Factory Made And Painted With Synthetic Enamel Paint Black Paint With And Including Top Cover 3Mm Thick Plastic Laminated Sheet ( Make : Hylum ) Of Required Colour Fixed With Brass Screws And Cup Washers With And Including 1.5 Sqmm Frls Multi Stranded Copper Conductor As Continuous Earth Wire Drawn In Same Concealed Conduit, Connected To Main Earth And Earth Dolly Including Cutting Chases And Making Good As Per Existing Specification For One Light Point Controlled By Two, Two Way Switch 5Amp Complete All As Specified And Directed. 17 Material And Labour For Point Wiring Complete Withpvc Insulated Unsheathed 1100 Volt Grade Frls Cable With Multi Stranded Copper Conductor Of Size 1.5 Sq Mm ( Nominal Area ) Drawn Through And Including Pvc Conduit ( Medium Duty ) Of Suitable Size ( As Per Conductor Run ) With All Fittings And Accessories Concealed In Wall And Ceiling Portion Inculding Concealed Sunk In Pressed Steel Terminal Bozes Of Not Less Than 2Mm Thick Required Size Factory Made And Painted With Synthetic Enamel Paint Black Paint With And Including Top Cover 3Mm Thick Plastic Laminated Sheet ( Make : Hylum ) Of Required Colour Fixed With Brass Screws And Cup Washers With And Including 1.5 Sqmm Frls Multi Stranded Copper Conductor As Continuous Earth Wire Drawn In Same Concealed Conduit, Connected To Main Earth And Earth Dolly Including Cutting Chases And Making Good As Per Existing Specification For One, 3 Pin 5Amp Switch Socket Outlet On Same Board Complete All As Specified And Directed. 18 Material And Labour For Point Wiring Complete Withpvc Insulated Unsheathed 1100 Volt Grade Frls Cable With Multi Stranded Copper Conductor Of Size 1.5 Sq Mm ( Nominal Area ) Drawn Through And Including Pvc Conduit ( Medium Duty ) Of Suitable Size ( As Per Conductor Run ) With All Fittings And Accessories Concealed In Wall And Ceiling Portion Inculding Concealed Sunk In Pressed Steel Terminal Bozes Of Not Less Than 2Mm Thick Required Size Factory Made And Painted With Synthetic Enamel Paint Black Paint With And Including Top Cover 3Mm Thick Plastic Laminated Sheet ( Make : Hylum ) Of Required Colour Fixed With Brass Screws And Cup Washers With And Including 1.5 Sqmm Frls Multi Stranded Copper Conductor As Continuous Earth Wire Drawn In Same Concealed Conduit, Connected To Main Earth And Earth Dolly Including Cutting Chases And Making Good As Per Existing Specification For One Three Pin 5Amp Switch Socket Outlet Point On Independent Board Complete All As Specified And Directed. 19 Material And Labour For Point Wiring Complete Withpvc Insulated Unsheathed 1100 Volt Grade Frls Cable With Multi Stranded Copper Conductor Of Size 2.5 Sq Mm ( Nominal Area ) Drawn Through And Including Pvc Conduit ( Medium Duty ) Of Suitable Size ( As Per Conductor Run ) With All Fittings And Accessories Concealed In Wall And Ceiling Portion Inculding Concealed Sunk In Pressed Steel Terminal Bozes Of Not Less Than 2Mm Thick Required Size Factory Made And Painted With Synthetic Enamel Paint Black Paint With And Including Top Cover 3Mm Thick Plastic Laminated Sheet ( Make : Hylum ) Of Required Colour Fixed With Brass Screws And Cup Washers With And Including 1.5 Sqmm Frls Multi Stranded Copper Conductor As Continuous Earth Wire Drawn In Same Concealed Conduit, Connected To Main Earth And Earth Dolly Including Cutting Chases And Making Good As Per Existing Specification For One Six Pin Socket Outlet Two In One 6 / 16 Amp Point On Independent Board Complete All As Specified And Directed. 20 Supply And Fixing Switch Piano, Flush Type, Single Pole, 2 Way, 6 Amp, 240 Volts Completeall As Specified And Directed. 21 Supply And Fixing Led Mirror Light Fittings 1X 18W, 220 Volt , Ac, Box Type With Driver, Including Led Tube Rod Connecting Up With And Including Three Core Flexible Copper Cable Conductor Cable Of Suitable Size From Ceiling Rose Including Hanging By Chain Or Hook Fitted On Two Round Blocks / Fixing Arrangements On Truss / Roof / Wall Completeall As Specified And Directed. 22 Supply And Fixing Led Mirror Light Fittings 1X 10W, 220 Volt , Ac, Box Type With Driver, Including Led Tube Rod Connecting Up With And Including Three Core Flexible Copper Cable Conductor Cable Of Suitable Size From Ceiling Rose Including Hanging By Chain Or Hook Fitted On Two Round Blocks / Fixing Arrangements On Truss / Roof / Wall Completeall As Specified And Directed. 23 Supply And Fixing Loadline Vertical Sheet Metal Enclosure Double Door For Distribution Board, Factory Made For Mccb Db Load Link Tpn 4 Way, 415 Volt, 50Hz Suitable For Mccb As Incomer, 4 Pole ( When Mcbs Are To Be Used ) With Suitable Size Of Busbar Complete Fixed On Wall Complete All As Specified And Directed. 24 Supply And Fixing Led Street Light Fitting 35 Watt, 230 Volt, Ac, Outdoor Type With High Pressure Die Cast Aluminium Housing And Heat Resistance Complete With Driver, Gi Bracket / Clamp With Impact And Corrosion Resistance Including Thermal Management In Multiple Optics Complete With Ip-65 / 66 Protection Unducting Connection Wire Of 1.50Sqmm 3 Core From Ceiling Rose To Light In Conduit Complete All As Specified And Directed. 25 Supply And Fixingexhaust Fan Made Of Steel Body Complete With Louvers Shutter Including Mounting Frame, Voltage 230V, 50 Hz, 900 Rpm, 36 Watt, Light Duty, Copper Winding Of Sweep 300Mm And All Accessories And Including Connecting Up With 1.50 Sqmm Three Core Flexible Copper Conductor Cable Of Suitable Size From Ceiling Rose Complete All As Specified And Directed. 26 Material And Labour For Sub Main Wiring With Pvc Insulated And Unsheathed Frls 1100 Volt Grade Electric Cable Of 4 Sqmm ( Nominal Area ) With Multi Stranded Copper Conductor Single Core Of 2 Run In And Including Pvc Conduit Not Less Than 20Mm Dia With All Accessories Including One Run Of Earth Wire Of Size 4 Sqmm Pvc Insulated Single Core, Multi Stranded And Unsheathed Copper Cable Continous Earth Wire With All Accessories Including Lugs Complete All As Specified And Directed. Note: 2 Runs Of 4 Sqmm, One Run Of 4 Sqmm As Earth Wire And One Run Of Pvc Conduit Shall Be Measured As One Unit. 27 M&L For Earthing Complete With Galvinised Steel Earthplate Electrode 60 Cm X 60Cm X 6Mm Thickburied Directly In Ground ( Earth Pit Notless Than2.25 Mtr Deep Belownormal Groundlevel ) With Top Edgeof Platenot Less Than1.5 Mtr Belownormal Ground Level , Connectingto Galvanised Iron Wire 4Mm Dia, Protected By Galvanised Iron Light Grade Pipe 15Mm Dia And Galvanised Iron Water Pipe Medium Grade 20Mm Dia Upto 7.5 Mtr Including Provnof Concretepit Inpcc ( 1:4:8 ) Type D-2 Using 40 Mm Graded Stone Aggregates, Coping Shall Be Pcc 1:3:6 Type C1 Using 20 Mm Graded Stone Aggregate, Top Cover 50Mm Thick Of Rcc 1:2:4 Type B1 Using 20Mm Graded Stone Aggregate Reinforced With 8Mm Dia Tmt Bars @80Mm C / C Both Ways With Angle Iron Frame, Pit Shall Be Given 15Mm Thick Plaster In Cm 1:4 , Funnel With Wire Gauge ( 0.68Mm ) And Charcoal Dust And Common Salt All As In Shown In Electrical Plate No-03 Of Mes Ssr Pt-I And Specified And Including All Excavation And Earth Work And Connecting The Earthing Complete All As Specified And Directednote: The Unit Quoted Rate Of Earthing Shall Be Deemed To Included Cost Of 7.5 M Long Gi Earth Wire 4Mm Dia And Protection Pipe Gi 15 Mm Dia Light Grade, Gi 20Mm Dia Medium Grade Watering Pipe. Any Variation In Length Shall Be Adjusted Through Deviation Order. 28 Supply And Fixing Mcb Sp 240 Volt, 50Hz , 10 Ka, C Curve Of Rating06 To 32 Amp Confirming To Is / Iec-60899-1 & Is / Iec-60947-2 Completeall As Specified And Directed. 29 Supply And Fixing Mcb Spn 240 Volt, 50Hz , 10 Ka, C Curve Of Rating6 To 32 Amp Confirming To Is / Iec-60899-1 & Is / Iec-60947-2 Completeall As Specified And Directed. 30 Supply And Fixing Mcb Spn 240 Volt, 50Hz , 10 Ka, C Curve Of Rating53 Amp Confirming To Is / Iec-60899-1 & Is / Iec-60947-2 Completeall As Specified And Directed. 31 Supply And Fixing Mcb Tpn 415 Volt, 50Hz , 10 Ka, C Curve Of Rating 63 Amp Confirming To Is / Iec-60899-1 & Is / Iec-60947-2 Completeall As Specified And Directed. 32 Supply And Fixing Mccb, 4 Pole, 415 Volt, 50Hz , 16 Ka, Of Rating 100 Amp Confirming To Is / Iec-60899-1 & Is / Iec-60947-2 Completeall As Specified And Directed. 33 Supply And Fixing Mcb Tp 415 Volt, 50Hz , 10 Ka, C Curve Of Rating 63 Amp Confirming To Is / Iec-60899-1 & Is / Iec-60947-2 Completeall As Specified And Directed. 34 Wood Work 35 Supply And Fixing 20Mm Thick 2Nd Class Soft Wood Boarding Fixed With Nails / Screws In Any Situation / Position Including 2Nd Class Soft Wood Plain Fillet, Including Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer On The External Surface Of The Building Complete All As Specified And Directed. 36 Hot Water Supply Works 37 Supply, Installation Testing And Commissioning Of 1000 Litre Kerosine / Diesel Based Hot Water Plant With Fuel Tank And Accessories With 1000 Litre Water Hearter Boiler Having Capacity Of 70000Kcal / Hr Oil Fires With Thermostat One Inch Thick Glass Wool Insulated, Automatic Air Release Valve, Oil Burner, Ms Oil Storage Tank Of 200 Litre Capacity With Powder Coated Outer Body Complete All As Specified And Directed. 38 Supply And Installation Of Ms Flue Gas Exhaust Pipe Made Out Of 3Mm Thick Ms Sheet, Minimum 1.2M Above The Highest Point Of The Plant Room And Including Connection From Hot Water Genderator To Main Vertical Exhaust Pipe Fabricated From 3Mm Thick Ms Sheet. The Item Shall Be Complete With The Mounting / Fixing Arrangeemnt. The Hot Water Generator Shall Be Connected To An Independent Flue Gas Exhaust Pipe Of Suitable Size And As Per Manufacturers Guide Lines. The Portion Of Hte Flue Gas Exhaust Pipe Inside The Builidn Shall Be Insulated With Fibre Glass Insulation Wool Of 24Kg / Cum With Aluminium Cladding. The Item Shall Be Complete With Mounting / Fixing Arrangement. 39 Lagging To Pipes Used In External Water Supply Or Plumbing All Round With, 25Mm Thick Bondedmineral Wool Preformed ‘Snap On’ Pipe Sections Of Density 144 Kg / Cum Conforming To Is 9842, Of 40Mm Dia Ppr Pipe, Provided With Chicken Wire Netting 25 Gauge, Mesh 20Mm Andwith Aluminium Foil 0.01Mm Complete All As Specified And Directed. 40 Lagging To Pipes Used In External Water Supply Or Plumbing All Round With, 25Mm Thick Bondedmineral Wool Preformed ‘Snap On’ Pipe Sections Of Density 144 Kg / Cum Conforming To Is 9842, Of 25Mm Dia Ppr Pipe, Provided With Chicken Wire Netting 25 Gauge, Mesh 20Mm Andwith Aluminium Foil 0.01Mm Complete All As Specified And Directed. 41 Lagging To Pipes Used In External Water Supply Or Plumbing All Round With, 25Mm Thick Bondedmineral Wool Preformed ‘Snap On’ Pipe Sections Of Density 144 Kg / Cum Conforming To Is 9842, Of 20Mm Dia Ppr Pipe, Provided With Chicken Wire Netting 25 Gauge, Mesh 20Mm Andwith Aluminium Foil 0.01Mm Complete All As Specified And Directed. 42 Material And Labour For Cutting The Existing Gi Tubing Of Size 50Mm Dia For Taking New Connection Of 25 / 40Mm Dia Gi Pipewith And Including Fittings Complete All As Specified And Directed. 43 Supply And Fixing Automatic Voltage Stabilizer For Low And High Voltage Connected Equipped With Electronic Transistors Relay Suitable For Connectin Of Single Phase, 50 Hz Ac Supply, Complete With Voltmeter And Designed For Input Voltage 170-220 Volt Of Capacity And Out Put Voltage Stabilized 230 Volt ± 2.5% Of Capacity 01 Kva Complete All As Specified And Directed. 44 Supply And Fixing Rotational Moulded Polythelene Water Storage Tank, Tripple Layer With Closed Hoisted And Fixed In Position Of 1000 Litre Capacity And Including Providing Laging All Around With 25Mm Thick Bonded Mineral Wool Performed Snap On Pipe Section Of Density 144 Kg / Cm Confirming To Is: 9842 Provide With Chicken Mesh 0.01 Mm Aluminium Foil For Entire Exposed Surface Of Tank Complete All As Specified And Directed. 45 Material And Labour For Sub Main Wiring ( Concealed ) Complete With Two Single Core 4.00 Sqmm Frls Pvc Insulated Unsheathed Stranded Copper Conductor Cable Drawn Through In And Including 20 Mm Dia Rigid Non-Metallic Pvc Conduit And Conduit Accessories Including One Single Run Of 4.00 Sqmm Frls Pvc Insulated Unsheated Stranded Copper Earth Cable Connected To Common Earth Dolly Complete And Including Cutting Chasing In Walls For Concealed Wiring Using Machine Cutting And Making Good The Disturbed Surface All As Specified And Directed.Note:- Three Runs Of 4.00 Sqmm Cable And One Run Of Pvc Conduit Shall Be Measured As One Unit. 46 Supply And Fix Electric Water Heater, Storage Type Steel Body With Copper Inner Tank And Heating Element Upto 2 Kw Capacity 25 Litre, Bee 5 Star Rated Complete With All Accessories Such As Safety Valve, Thermostate, Nrv, Connection Piece Etc. Complete All As Specified And Directed. 47 Supply, Installation, Commissioning And Testing Of Monoblock Centrifugal Pump Driven By Suitable Capacity Electric Motor For Hot Water Supply Of 12 / 32 Mtr Head Range Discharge 3600 / 700 Lph Complete With Accessories Including, Pressure Gauge, Nrv, Pressure Cutout Switch, Pressure Tank Including Pcc 1:2:4 Foundation Complete All As Specified And Directed. 48 External Water Supply Works 49 Material And Labour For Trail Drilling Bore Holein Alluvial Strata For Construction Of Deep Borewell Of 250Mm Dia With Reverse Rotary Rig Drilling Machine Complete With Driling Bits, Dril Shaft And All Other Accessories, Complete With Transportation, Errection Of Camp At Site And Removal Of All Tools And Plants On Completion Of Borewell Work For The Depth Upto 50 Metre From Ground Level As Complete All As Specified And Directed.Note: Work Will Further Execute On Successful Result Of Water Sample Testing Form Authorised Lab. ( Ii ) Water Availability Report From Cgwb Or Regulatory Body Of Govt Shall Be Arranged By The Bidder And Handed Over To The Department Before Drilling 50 All As Per Item No. 6.01 Here-In-Before But Depth Exceeding 50 Metre And Upto 100 Metre Below Ground Levelnote For Item No 6.01 To 6.02:- The Cost Of Necessary Fuel, Lubricant And Chemical Extra Required For Construction Of Work Shall Be Deemed To Be Included In The Unit Quoted Rate By The Tenderer And Nothing Extra Shall Be Paid For These Items. 51 Material And Labour For Development Of Bore Hole With Reaming Upto 550Mm Forborewell Of 250Mm Dia, For Depth Upto 100Metre From Ground Level Complete All As Specified And Directed. 52 Supplying, Assembling, Lowering And Fixing In Position 300Mm Nominal Bore Ms Erw Isi Marked Casing Blank Pipe Having Wall Thickness 8Mm As Per Is -4270 ( 2001 ) And Jointing With Electric Arc Welding, Random Length Of Pipe 3 To 6 Metre, Including Necessary Fittings, Ie. 200Mm Long Ms Sleeves Of Suitable Size, Coupling, Jointing And Painting With Two Coats Of Bituminous Paint Of External Surfaces Of Pipe Upto Depth Of 76Metre Below Ground Level Complete All As Specified And Directed. 53 Supplying, Assembling, Lowering And Fixing In Position 300Mm Nominal Bore Ms Erw Isi Marked Casing Blank Pipe Having Wall Thickness 8Mm As Per Is -4270 ( 2001 ) And Jointing With Electric Arc Welding, Random Length Of Pipe 3 To 6 Metre, Including Necessary Fittings, Ie. 200Mm Long Ms Sleeves Of Suitable Size, Coupling, Jointing And Painting With Two Coats Of Bituminous Paint Of External Surfaces Of Pipe Upto Depth From 76 Metre To 100 Metre Depth Below Ground Level Complete All As Specified And Directed. 54 Material And Labour For Electro Logging Of Bore Well For Designing And Lowering Of Pipe Assembly On Logging Report / Graph Complete All As Specified And Directed. 55 Material And Labour For Bail Plug Made Out Of Ms Housing Pipe 300Mm Dia, Wall Thickness 8Mm, One And Half Metre Long Blocked With 10Mm Thick Ms Plate With Bottom Hook Incld Jointing With Electric Arc Weldingcomplete All As Specified And Directed. 56 Material And Labour For Centre Guide Made Of Ms Flat Iron ( 40X6mm ) Incld Jointing With Electric Arc Welding With Casing Complete All As Specified And Directed. 57 Supply And Filling Of Cleaned And Washed, Pea Gravel Of Size 3Mm To 6Mm Packing Around The Pipe Bottom To Ground Level Complete All As Specified And Directed. 58 Material And Labour For Ms Clamp Suitable For 300Mm Dia Housing Pipe Made For 150 X 20Mm Thick Plate Including Bolts / Nuts And Washers Of Required Size Complete All As Specified And Directed. 59 Material And Labour For Well Cap Made Out Of 6Mm Thick Ms Plate Suitable For 300Mm Housing Pipe To Provide Cover At Top Of Borewell Complete With Locking Arrangement Using 25Mm Dia, 400Mm Long Ms Bolt Slotted Through The Cap And Casing Pipe With And Including 1 No Lock Complete All As Specified And Directed. 60 Material And Labour For Development Of Bore Well With Air Compressor Not Less Than 200 Psi Compressor Over Pumping Unit Till Sand Free Water Obtained And Testing The Yeild For Duration As Under Complete All As Specified And Directed For First 24 Hours By Using Air Compressor Complete All As Specified And Directed.Notes: - ( A ) Contractor Has To Provide Own Dg Set / Prime Mover To Run Compressor And Over Pumping Set. ( B ) All Type Of T&P And Transportation Required For Development Of Bore Shall Be Arrange By The Contractor And Cost Of These Items Shall Be Deemed To Be Included In The Unit Quoted Rate. 61 All As Per Item No. 7.12 Here-In-Before But Subsequent48 Hours After First 24 Hours 62 Material And Labour For Foundation For Holding Borewell Assembly Of Size 1.0M X 1.0M X 1.0M At Ground Level Made Of Pcc 1:2:4 Type B-2 Using 40Mm Graded Crushed Stone Aggregate With Gi Pipe 80Mm Bore Medium Grade At Three Places, Embedded Through Out The Block 1.70Metre Length For Feeding Gravels And Gi Plug And Socket Fixed On Top Complete All As Specified And Directed. 63 Material And Labour For Strata Sample Box With Glass Cover 3Mm Thick And Having Minimum Internal Dimension 1.20M X 750Mm X 100Mm Made Out Of Shisham 1St Class Hard Wood Planks, 20Mm Thick With Hinges Staple Including Painting Two Coats Of Synthetic Enamel Paint Over A Coat Of Primer Complete With Soil Sample Placed In Position Of 200Mm Wide Made With Wood Planks 20Mm Thick, Cover With Aluminium Frame All Around With 02 Nos Key Holes Plates Of Size 40Mm X 25Mm And 3Mm Thicfk Complete Showing Name Of Tube Well Locaation And Preparation / Installation Of Starata Chart Of Ground Data Showing Different Type Of Starta And Selection Of Casing Pipe On Good Quality Rg Sheet Paper With Size Of Chart 80Cm X 30Cm Complete All As Specified And Directed.Note: - The Number Of Poriton May Vary With Type Of Soil Starata Met And Over All Length Of The Bore And Can Be Increased. 64 Material And Labour For Yeild Test For The Borewell By Continously Pumping For 16 Hours To Determine Using V Notch Constructed At Site Complete All As Specified And Directed. Note: - Chemical / Bacteriological Analysis And Potability Test Of Water Obtained From Borewell Shall Be Done From Approved Lab And Submitting The Report In Triplicate Shall Be Deemed To Be Included In The Unit Quoted Rate. 65 Material And Labour For Tripod Made Out Of Heavy Duty Gi Pipe 80Mm Bore Suitable For 2 Ton Capacity With Nut And Bolt And Hook For Suitable Sizecomplete All As Specified And Directed. 66 Supply And Fixing Chain Pulley Block 2 Ton Capacity With Heavy Duty Chain Suitable For Working 3Metre Abvoe Ground Level, Chaind 10Metre Long Complete All As Specified And Directed. 67 Supply, Installation, Testing And Commissioning Of Submersible Pump 20Hp Electric Drivenm 415V, Tp Suitable For Gi Pipe 80Mm Dia, Discharge Capacity 165 Lpm, Head 120Metre Including Suitable Size Of Flexible Steel Rope For Holding Submersible Motor Pump Complete All As Specified And Directed. 68 Supply, Laying And Testing Of Submersible Copper Cable Of Size 10Sqmm, 3 Core For Submersible Pump Complete All As Specified And Directed. 69 Supply, Installation, Testing And Commissioning Of Chemical Dosing System Suitable To Inject Solution Upto 25Lph Comprising Dosing Pump Coupled With Single Phase Electric Motor Of Capacity 0.5Hp, 1440 Rpm Assembly Including Dol Starter Suitable Capacity With Agitator Dosing And Agitator In Single Motor, Agitator With Ss Sweep Blade Duly Frp Coated, Frp Double Tank 150 Litre Capacity, Complete Unit Mounted On Heavy Duty Ms Fabricated Frame Duly Painted With Anti Corrosive Paint Including Packing, Electrical & Pumping Works Etc. Complete All As Specified And Directed.Note: - The Cost Of Electrical Connection Like Point Wiring And Socket Point Requreid For Smooth Functioning Of Dosing Plant And T&P Shall Be Included In The Unit Quoted Rate. 70 Supply And Fixing Upvc Pipe Of 20Mm Dia Confirming To Is 4985 / 2000 Complete Including Necessary Clamps And Fittings, Jointing Material Etc. Complete All As Specified And Directed. 71 Supply And Lowering In Borewell, Ms Erw Is-4270 ( 2001 ) Column Pipe Of Size 100Mm Bore In 3Metre Length, Both Ends Flanged With 10Mm Thick Ms Flange Including Cutting Holes ( 04 Nos ) Of Size 10Mm Dia For Passing The Submersible Cable, With And Including Suitable Size Of Covering Nuts, Bolts, Washers And Rubber Gasket Complete All As Specified And Directed. Note: - All Arrangements And T&P Requried For Lowering The Column Pipe In The Bore Shall Be Made By The Contractor Under Their Own Arrangement At No Extra Cost. 72 Material And Labour For Fabrication Of Water Level Indicator Including Float Ball Assembly Setof Standard Size / Weight Consisting Of Rustless / Corrosion Proof Pvc Float Valve Or 2Nd Quality Wood, Flexible Steel Wire Ropes, Ms Indicator Pointer, Steel Structural Frame To Be Fixed Vertically With Dome Of Tank Ms Flat Iron / Angle Iron, Ms Pulleys, Nuts, Bolts, Washers Etc Of Suitable Size For Proper Jointing, Fixing, Level Markeing, Water Depth As Per Water Level In Over Head Tank In Position And Testing Complete All As Specified And Directed. Note: - Timber Shall Be 2Nd Class Hard Wood And Ms Sheet Shall Be 20 Gauge. 73 Material And Labour For Construction Of Valve Pit Of Size 60Cmx60cmx60cm ( Internal Dimensions ) By Excavation And Earth Work In Any Type Of Soil, Removal, Disposal Of Surplus Spoil To A Distance Not Exceeding 50M And Depositing Where Directed, Pcc ( 1:4:8 ) Type D-2 ( Using 40Mm Graded Crushedaggregate ) In Foundation, Brick Masonary In Cement Mortar ( 1:6 ) Using Old Size Sub Class B Bricks, Rendering 15Mm Thick In Cement Mortar ( 1:4 ) Internally, Neeru Finished Externally As The Work Proceeds In The Same Mortar, Coping In 1:2:4 ( Using 20Mm Graded Stone Aggregate ) , Angle Iron Frame ( 40X40x6mm ) , Ms Sheet Cover 3.15 Mm Thick With Sleeve Piece, Frame Work, Butt Hinge 125Mm Size With Handle 100Mm Of Ms Bar And Locking Arrangement, Paintingall The Exposed Ms Work With Two Coats Of Synthetic Enamel Paint Of The Tint As Approved By The Ge Over A Coat Of Red Oxide Primer And Painting All The Ms Embedded In Pcc With Two Coats Of Black Bituminous Paint Including Excavation And Earth Work, Internal And Three Coats Of White Wash On Exposed Plastered / Concrete Surfaces Complete All As Specified And Shown On Drawings. 74 Materail And Labour For Non Return Valve 100Mm Dia Complete All As Specified And Directed. 75 Materail And Labour For Ppr Gate Valve ( Brass Insert ) Of Outer Dia 90Mm Dia And Fixing Up In Water Supply Mains Complete All As Specified And Directed. 76 Materail And Labour For Ppr Gate Valve ( Brass Insert ) Of Outer Dia 63Mm Dia And Fixing Up In Water Supply Mains Complete All As Specified And Directed. 77 Materail And Labour For Ppr Gate Valve ( Brass Insert ) Of Outer Dia 32Mm Dia And Fixing Up In Water Supply Mains Complete All As Specified And Directed. 78 Materail And Labour For Ppr Gate Valve ( Brass Insert ) Of Outer Dia 25Mm Dia And Fixing Up In Water Supply Mains Complete All As Specified And Directed. 79 Materail And Labour For Ppr Gate Valve ( Brass Insert ) Of Outer Dia 20Mm Dia And Fixing Up In Water Supply Mains Complete All As Specified And Directed. 80 Supply And Fix Sluice Valve, 100Mm Dia Complete All As Specified And Directed. 81 Lagging To Pipes Used In External Water Supply Or Plumbing All Round With, 25Min Thick Bondedmineral Wool Preformed ‘Snap On’ Pipe Sections Of Density 144 Kg / Cum Conforming To Is 9842, Of 20Mm Dia Ppr Pipe, Provided With Chicken Wire Netting 25 Gauge, Mesh 20Mm Andwith Aluminium Foil 0.01Mm Complete All As Specified And Directed. ( Ext W / S 147, Hot W / S =39 ) 82 External Electric Supply Works 83 Supply, Installation, Testing And Commissioning Ac, 3 Phase, 50Hz , 16 Kva Level-2, Capacity Transformer Copper Wound Step Down Pole Mounted ( 2 Pole Structure ) Out Door Type, 11000 / 433 Volt ( At No Load ) Double Wound Oil Immersed Naturally Cooled With External Cooling Tubes, Core T Ype Delta Conneted On Primary Side ( Hv ) And Star Connected In Secondary Side ( Lv ) In Accordance With Vector Symbol Dyn 11 ( Vector Group ) With Neutral Brought On Secondary Side ( Lv Side ) And Having Tapping At ± 2.50%, ± 5.0% And ±7.50% To Changed By Means Of Hand Operated Off Load Tap Changing Gera. The Maximum Centigrade In Hv / Lv Winding When Meased By Resistance Method After Continous Full Load Run In Ambient Temp Of 40 Degree Centigrade And Teh Transformer Shall Be Confirming To Is: 1180 2014 Level -2, Bis Mark And Fitting / Accessories Of The Following: - ( A ) Three Nos Porcelain Bushing For 11 Kv On Hv Side Complete With Copper Rods, Nuts And Washers. ( B ) One Cable Box On Lv Side ( Secondary ) Consisting Of Four Nos Porcelain Bushing With Copper Rods, Complete With Nuts And Washers With Cable Glands Suitable For Reception / Taking Out Of 03 Nos Single Core 95Sqmm And One 50Sqmm Lt 1100 Volt Grade Xlpe Insulated And Sheathed, Heavy Duty Armoured Cables Including Joints And Jointing Material Complete. ( C ) One No 100 Dia Dial Type Thermometer, Vapour Type Pressure Having Range 0 To 120 Degree Celcius With Metal Guard Having Maximum Perimeter Temperature Reducing Indicator With Resetting Device. 84 ( D ) Two Earthing Terminals On Tank Cover To Facilitate Fixing Of 50 X 6 Mm Galvanised Iron Earth Strip For Body Earthing. ( E ) Dehydrating Breather With Clear View Type And Filled With Silica Gel ( F ) Rating And Terminal Marking Plate. ( G ) Extra Bushing For Neutral In The Lt Cable Box For Providing Independent Set Of Earthing For Neutral. ( H ) First Filling Of New And Unused Transformer Oil Confirming To Is-335 Marked, Filtered And Testing Upto 50Kv Bdv Value. ( J ) Explosion Vent, Thermopocket On Tank Cover, Oil Level Gauge, Oil Drain Filter Vlave, Lifting Lugs, Oil Filling Holes With Cap / Plugs With Connection Plate Complete, Air Relrease Valve Plug And Four Nos Plain Solid Vest Steel Detachable Rollers. ( K ) All Other Accessories Not Specified Above And As Per Oem Standard Or As Directed. 85 Notes :- ( I ) Routine Test As Per Is, Shall Be Carried Out At The Works. Type Test Including Temperature Rise Test Shall Also Be Carried Out At Factory. Site Tests Are Also To Be Carried Out In Presence Of Company Rep. All The Tests Whether At Factory / At Site Are To Be Conducted In Presence Of Mes Rep And All Test Certificates Duly Signed By All Concenerned To Be Submitted By The Contractor To The Dept. ( Ii ) The Equipment Should Carry A Gurantee Of 30 Months From Date Of Despatch Or 24 Months Form Date Of Completion Of The Contract Whichever Is Later. Any Defect During This Period Will Be Attended In A Period Of Three Days Including Spares And Labour. ( Iii ) The Errection Of Transformer Shall Be Done As Per MnufacturerS Auth Rep & Certificate In This Regard Shall Be Submitted By Contractor Duly Signed By Auth Rep Of Manufacturer & Engr-In-Charge. ( Iv ) Rtcc Panel Shall Be Suitable For Automatic Valtage Regulation With Master Follower Scheme With Tap Position Indicator As Per Tap Indicatioin In The Oltc Mechanism. Rtcc Should Also Be Provided With Central Gear In Respect Of Fan On / Off Indication, Auto & Manual Control Switch , Ac Supply On And Tap Changer In Progress Indication Lamp, Tap Struck Indication And Alarm. ( V ) The Core Shall Be Constructed From High Grade Non Ageing, Prome Good Crgo With M4 Grade Or Vetter Silicon Steel Laminationi And Shall Be Og Bottle Ness Design. ( Vi ) Manufacturer Shall Have In House Automatic Core Cutting Facility To Ascertain That There Is No Mixing Of Second Grade Core. ( Vii ) Manufacturer Shall Have In House Nabl Accredited Lab To Ascertain The Authenticity Of Test Result. 86 Supply, Install, Commissioning And Testing Ofcpri Approved Outdoor Type Lt Panel Board Suitable For 440 Volt, 3 Phase & Neutral, 50Hz Supply, Floor Mounted Weather And Vermin Proof Fabricated From Ms Angle Of Size 50X50x5mm As Base Frame, With 3Mm Thick Crca Sheet ( Make Tata / Sail ) ( Load Bearing Members 3Mm Thick And Non Load Bearing Memebers Suchas Doors Partitions Etc Of Thickness 1.6Mm Thick ) With Gland Plates At Bottom With Suitable Brass Chromium Plated Glands, With Cadmium Plated High Tensile Nut And Bolts Washers, Suitable Lugs For Cable Terminations Complete With Locking Arrangements Complete Sheetes Bend Folded, Cut With Cns Machine For Hte Accuracy Of Diamensions ± 0.5%Duly Powder Coated With Siemens Grey Colour After Chemical Treatment, With Suitable Ventilation Fan At The Top , Including Led Tyb Inidcators - 06 Nos On Incoming Side And On / Off / Trip Indications On Outgoingside Of Breaker, Interconnections From Bus Bars To Mcbs / Mccbs With Suitable Size Aluminium Bus Bars, All Internal Protection Wiring With Frls 1100 Volt Grade Wiring With Mcb Protection, Including Terminal Adapters, Spreader Links On Incoming And Out Going Sides Of Mcbs / Mccbs Complete All As Specified And Directed With Ip-54 Protection And Comprising Of The Following: - 87 Mccb 4 Pole 200 Amp, 35 Ka, 415 Volt ( 01 Noincoming ) Confirms To Is / Iec 60947-2, Ics=100% Of Icu, Etm ( With In Built Earth Fault Protection ) , Adjustable Overload 40-100% Adjustable Shortcircuit, Ir Setting, Transparent Release Cover- 01 No. 88 Outgoing Mccb 4P, 32Amp, 25Ka-02 Nos ( Ch / Dh, 47 Hav ) , Atm ( Thermal Magnetic ) Release, Adjustable Overload 80-100%, Adjustable Short Circuit 5-10 In Suitable For 220 / 230V, Ac 50Hz System 89 Outgoing Mccb 4P, 160Amp, 25Ka-01 No ( Main Panel To Dg Amf ) , Atm ( Thermal Magnetic ) Release, Adjustable Overload 80-100%, Adjustable Short Circuit 5-10 In Suitable For 220 / 230V, Ac 50Hz System 90 Digital Volt Meter 0-500V With Selector Switch-1 Set 91 Digital Ammeter With Suitable Cts Rating ( Cts 200 / 5 A -03 Nos ) And Selector Switch-1 Set 92 Led Type Indication Lamps With Switches And Fuses ( R, Y, B ) - 1 Set 93 Aluminium Bus Bar Chamber Of Capaciry With Bus Bar 400 Amp Tpn With Bus Bar Insulator- 01 Set 94 Internal Wiring With Suitable Size Single Core Copper Conductor Cable Of Red, Yellow, Blue And Black Colour Including Lugs, Ferrule, Tag Etc. 95 Note: ( I ) The Rate Quoted Is Inclusive Of Necessary Cts, Control Wiring And Instrument Fuse Holder. 96 Supply, Install, Commissioning And Testing Ofcpri Approved Outdoor Type Lt Panel Board Suitable For 440 Volt, 3 Phase & Neutral, 50Hz Supply, Floor Mounted Weather And Vermin Proof Fabricated From Ms Angle Of Size 50X50x5mm As Base Frame, With 3Mm Thick Crca Sheet ( Make Tata / Sail ) ( Load Bearing Members 3Mm Thick And Non Load Bearing Memebers Suchas Doors Partitions Etc Of Thickness 1.6Mm Thick ) With Gland Plates At Bottom With Suitable Brass Chromium Plated Glands, With Cadmium Plated High Tensile Nut And Bolts Washers, Suitable Lugs For Cable Terminations Complete With Locking Arrangements Complete Sheetes Bend Folded, Cut With Cns Machine For Hte Accuracy Of Diamensions ± 0.5%Duly Powder Coated With Siemens Grey Colour After Chemical Treatment, With Suitable Ventilation Fan At The Top , Including Led Tyb Inidcators - 06 Nos On Incoming Side And On / Off / Trip Indications On Outgoingside Of Breaker, Interconnections From Bus Bars To Mcbs / Mccbs With Suitable Size Aluminium Bus Bars, All Internal Protection Wiring With Frls 1100 Volt Grade Wiring With Mcb Protection, Including Terminal Adapters, Spreader Links On Incoming And Out Going Sides Of Mcbs / Mccbs Complete All As Specified And Directed With Ip-54 Protection And Comprising Of The Following: - 97 Mccb 4 Pole 160 Amp, 25 Ka, 415 Volt ( 01 Nos Incoming ) Confirms To Is / Iec 60947-2, Ics=100% Of Icu, Etm ( With In Built Earth Fault Protection ) , Adjustable Overload 40-100% Adjustable Shortcircuit, Ir Setting, Transparent Release Cover- 01 No. ( From Dg Output Supply ) 98 Outgoing Mccb 4P, 32Amp, 25Ka-02 Nos ( For Borewell ) , Atm ( Thermal Magnetic ) Release, Adjustable Overload 80-100%, Adjustable Short Circuit 5-10 In Suitable For 220 / 230V, Ac 50Hz System 99 Outgoing Mccb 4P, 100Amp, 25Ka-01 No ( Chs ) , Atm ( Thermal Magnetic ) Release, Adjustable Overload 80-100%, Adjustable Short Circuit 5-10 In Suitable For 220 / 230V, Ac 50Hz System 100 Outgoing Mcb 2P, 32 Amp, 16Ka-01 Nos ( Internal Lights ) 101 Digital Volt Meter 0-500V With Selector Switch-1 Set 102 Digital Ammeter With Suitable Cts Rating ( Cts 200 / 5 A -03 Nos ) And Selector Switch-1 Set 103 Led Type Indication Lamps With Switches And Fuses ( R, Y, B ) - 1 Set 104 Aluminium Bus Bar Chamber Of Capaciry With Bus Bar 300 Amp Tpn With Bus Bar Insulator- 01 Set 105 Internal Wiring With Suitable Size Single Core Copper Conductor Cable Of Red, Yellow, Blue And Black Colour Including Lugs, Ferrule, Tag Etc.Note: ( I ) The Rate Quoted Is Inclusive Of Necessary Cts, Control Wiring And Instrument Fuse Holder. 106 Supplying, Transporting, Erecting And Fixing Of Steel Tubular Swaged Poles Type 410, Sp-31 ( 9 Metre Long ) With 300Mmx300mmx6mm Cast Iron Base Plate, Finial Tapper Plug, Bolts, Nuts And Screws And Making Holes As Per Requirement All As Specified Including Painted With Two Coats Of Synthetic Enamel Paint In Strips Of 30Cm Width, Black And Yellow Alternately And Painted With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer On Rest Of The Pole And Its Connected Parts Etc. Complete All As Specified And Directed.Note:- Necessary Excavation & Earth Work And Pcc In Coping / Foundation Shall Be Measured And Paid For Separately . 107 Supply And Fixing Led Street Light Fittings, 60 Watt, 230 Volt, Ac, Outdoor Type With High Pressure Die Cast Aluminium Housing And Heat Resistant Complete With Driver, Lamp Bracket With Impact And Corrosion Resistant Including Thermal Management In A Multiple Optics And Connecting Up With And Including Suitable Size 3 Core Wire Not Less Than 0.5Sqmm From Street Light Terminal To Junctin Box Housed In Pvc Conduit 20Mm Dia Complete With Ip65 / 66 Protection Complete All As Specified And Directed. 108 Supply And Fixing Cable Junction Boxes, Ip 65 Protected, Halogen Free And Weather Proof, Suitable For Out Door Type ( With Metric Knockouts For Cable Entry ) Of Size 333 X 233 X 120Mm Including Necessary Suitable Size New Backelite Connecting Terminals, Mounted On Saddles, Suitable For 3 Phase With Neutral System - 04 Nos Of Suitable Length, Thickness And Connecting The Incoming And Outgoing Lt Cable Connections In The Terminal Block Of Junction Box And Fixing Clamps Made Up Of Gi Flat Of Size 25 X 6 Mm Of Suitable Length-02 Sets, Including Gi Nuts And Bolt And Washers On Poles Complete All As Specified And Directed. 109 Supply And Laying Synthetic Rubber Insulated Mat 2.5Mm Thick For Voltage Upto 3.3Kv For Electrical Purpose As Per Is 15652-2006, ( Superceeding Is5424 ) Sutiable For Electric Shock Safety T Ype Of Size 2M X 1M Complete All As Specified And Directed. 110 Supplying, Transporting, Erecting And Fixing Of Steel Tubular Swaged Poles Type 410, Sp-55 ( 11 Metre Long ) With 300Mmx300mmx6mm Cast Iron Base Plate, Finial Tapper Plug, Bolts, Nuts And Screws And Making Holes As Per Requirement All As Specified Including Painted With Two Coats Of Synthetic Enamel Paint In Strips Of 30Cm Width, Black And Yellow Alternately And Painted With Two Coats Of Aluminium Paint Over A Coat Of Red Oxide Primer On Rest Of The Pole And Its Connected Parts Etc. Complete All As Specified And Directed.Note:- Necessary Excavation & Earth Work And Pcc In Coping / Foundation Shall Be Measured And Paid For Separately . 111 Supply, Installation, Commissioning And Testing Of Servo Voltage Stabilizer Fully Automatic, Microprocessor Based Control Card Of Capacity 200 Kva, Three Phase Oil Cooled, Indoor Type And Designed For Input Variation Between 260V To 480V, Output Voltage Stabilized At 415V With Accuracy Of Plus Of Minus 1% And Speed Of Voltage Correction Should Not Be Less Than 8V / Sec, Input Frequency 47 To 53 Hz Having Facility To Auto And Manual Operation, No Load Loss Should Be Less Than 0.5%, Operatin Temperature-18 Degree To 45 Degree Centigrade Above Ambient And Suitable To Operate With Unbalanced Load Including Initial Oil Filling Upto Appropriate Level With New Transformer Oil And Having All Standard Accessories ( I.E. Voltmeter, Amp Meter, Set Of Cts Of Appropriate Ratio, Selector Switch, Sufficient Number Of Led Indicator Lamps, Toggle Switch For Auto And Manual Mode, Push Buttons For Voltage Lower / Raise And Indication For Bypass Arrangement Etc Complete All As Specified And Directed With And Including Following Additional Features:- 112 ( A ) High And Low Voltage Cut Off System ( B ) Single Phase And Reverse Polarity Protection ( C ) Suitable Size Of Mccb With Appropriate Short Circuit Rating With Over Load Andshort Circuit Protection And Having Adjustable Thermal And Magnetic Setting ( D ) Incomer Control By Appropriate Rating Of Mccb 4 Pole ( E ) By Pass Arrangement By Providing On Load Change Over Switch 4 Pole Ofsuitable Rating. 113 Supply And Fixing Pcc Ht Cable Route Indicaters Of Sie 300 X 500 X 40Mm Duly Embossed Ht Cable / Lt Cable With And Including Fixed In Pcc ( 1:2:4 ) Foundation Complete All As Specified And Directed. 114 M&L Forsand Cushioning In Trenches With A Layer Of Sand 80 Mm Thick Before Laying Of Cable And 150 Mm Thick After Laying Of Cable For Protection Of Cablecomplete All As Specified And Directed. ( Exc Elect=72.9, Hot W / S=4.05, Path = 7.5 ) Note :- Punned Thickness Shall Be Measured And Paid As Per Ssr Part-1 2009. 115 Material & Labour For Un-Reinforced Precast Concrete Cable Cover Class Lv, Type I, Flat Size 250Mm X 150Mm X 40Mm For Protection Of Cable Complete All As Specified. ( Exc Elect=5625, Hot W / S=312 ) 116 Material & Labour For Un-Reinforced Precast Concrete Cable Cover Class Hv, Type I, Flat Size 300Mm X 180Mm X 40Mm For Protection Of Cable Complete All As Specified. 117 M&L For Earthing Complete With Galvinised Steel Earthplate Electrode 60 Cm X 60Cm X 6Mm Thickburied Directly In Ground ( Earth Pit Notless Than2.25 Mtr Deep Belownormal Groundlevel ) With Top Edgeof Platenot Less Than1.5 Mtr Belownormal Ground Level , Connectingto Galvanised Iron Earth Strip 32X6 Mm, By Means Of Bolt Nuts, Check Nutsnutsand Washer Of Galvanised Medium Grade Pipe 15Mm Diaupto 7.5 Mtr Including Provnof Concretepit Inpcc ( 1:3:6 ) Type C-1 Using20 Mm Graded Stone Aggregates, With Fair Finish , Internal Surface Of Concrete Chamber Shall Be Given 15Mm Thick Plaster In Cm 1:4 , Funnel With Wire Gauge ( 0.68Mm ) 8Mesh Per Liner Inch , 80 Mm Thickrcc Pit Cover 320Mmx320mm Of Concree ( 1:2:4 ) Type B-1 Using 20 Mm Aggregate Reinforcedwith Xpm Jalli And Charcoal Dust And Common Salt All As In Shown In Electrical Plate No-03 Of Mes Ssr Pt-I And Specified Including Provision Of Earth Lead Strip Protected By 40 Mm Dia Light Grade Gi Pipe And Watering Pipe Shall Be 20 Mm Dia Medium Grade And Including All Excavation And Earth Work And Connecting The Earthing To And Earthingtest Point / Transformer Neutral / Body / Lt Panel Etc. And Testing On Completion , Complete All As Specified And Directed ( External Electric=10, Dg Set=4 ) Note: The Unit Quoted Rate Of Earthing Shall Be Deemed To Included Cost Of 7.5 M Long Gi Earth Strip 32X6 Mm And Protection Pipe Of 40 Mm Bore Light Grade, Gi 20Mm Dia Medium Grade Watering Pipe. Any Variation In Length Shall Be Adjusted Through Deviation Order. 118 Dg Set Works 119 Supply, Installation, Testing And Commissioning Of Silent Type Diesel Engine Driven Generating Set With Governing Class G2 Including Sound Reducing Canopy ( Sound Level Not More Than 75 Decibel From 1 Mtr Distance ) 16 Gauge As Per Guideline Issued By Central Pollution Control Board, 415 Volts, 3 Phase, 50 Hz Supply Complete With Panel For Automatic Starting On Main Failure Control Panel Suitable For Giving An Output Of 100 Kva After Considering Derating Factor Confirming To Is-1601 At 9500 Feet ( Approx ) Altitude Above Mean Sea Level And Capable Of Operating Between Temperature Range ( - ) 20 Degree Centigrade To ( + ) 40 Degree Centigrade ( At Sonamarg, J&K ) And Alternator Of Suitable Capacity And Rpm Coupled With Each Other With Flexible Coupling Mounted On Common Base Plate On Anti Vibration Pads On Foundation As Recommended By Manufacturer. The Dg Set Shall Comprise Of Amf Panel With Auto Change Main To Generator And Vice Versa Electric Starter Motor With Batteries, Water Cooled & Comprising All Standard Fittings, Fixtures And All Piping Etc As Below:- 120 ( A ) Alternator: Directly Coupled With Engine And Suitable To Produce 415 Volts, 3Phase 4 Wire System, 50 Hz 0.8 Power Factor @ 1500 Rpm Of Capacity 100 Kvaall As Per Is-13364 And Upto Date Amendments With H Class Insulation Selfexcited, Self Regulated, Screen Protected Drip Proof Type With Two End Shieldball / Roller Bearing With Damper Winding In Each Pole Ass As Specified And Directed. 121 ( B ) Engine: Water Cooled Diesel Engine ( Cpcb Norms Compliance ) Developingsuitable Bhp As Recommended By The Manufacturer For 9500 Feet Altitude Atsonamarg Area Of J&K Having Self Start Engine ( Including Batteries With Provisionof Charging The Batteries And Leads ) Suitable To Derive Above Specified Alternatorcomplete With Foundation ( Foundation Design As Per Oem ) , As Per Is- 10001 / 10002, Coupled Directly Through Flexible Coupling, Multi Cylinder Four Stroke, Cold Starting, 1500 Rpm Industrial Type With Ai Electronic Governer Suitbale Toregulate Speed Of Dg Set From No Load To Full Load Complete With Fuel Tank Ofcapacity As Per Manufacturer Recommendations, Fuel Lines, Exhaust Pipe Dulyinsulated With Asbestos Rope And With Support And Silencer Mufflers Etc Forcontinuous Operation And Standard Accessories, Sump Pre Heaters, Cold Start Kitetc All As Specified And Directed. 122 ( C ) Canopy : Canopy Enclosure Shall Be Powder Coated And Fabricated Out Ofpower Coated After Passing Through Seven Tank Process 16 Swg Crca Ms Sheetand Lockable Doors Should Be Provided In Canopy With Lockable Fuel Fillingarrangement Provided External To The Canopy, The Exhaust System And Noisesuppressor Shall Be Provided With Thermal Insulation By Using Fire Retardant / Nonigniting Foam To Prevent Exess Heat Radiation On The Engine And Safe For Operator.Absorption Type Non Resistance Residential Silence Shall Be Provided To Suppressexhaust Noise Form The Engine. 123 ( D ) Alignment And Fuel Tank : Alternator And Engine Aligned On A Common 14 Swg Crca Ms Base Frame Complete With Ms Fuel Tank, Fabricated Out Of 14 Swg Crca Ms And Is Part Of Base Frame. ( E ) Generating Panel : Dg Set Should Consist Of Amf Generating Panel Autostaring On Main Failure Mounted As Per Manufacturer. ( F ) Maintenance Spares :- ( I ) Fuel Filter Element -02 Nos ( Ii ) Oil Filter Element -03 Nos ( Iii ) Element Air Cleaner Outer -06 Nos ( Iv ) Element Air Cleaner Inner – 06 Nos ( V ) ‘V’ Belt -02 Nos ( Vi ) Filter Lubricant Oil Bypass – 06 Nos ( G ) Dg Set Shall Be Supplied Alongwith Acoustic Enclosure Of The Manufacturersuitable For 100 Kva Dg Set As Per Cpcb Norms. 124 Notes:- The Quoted Rates Shall Be Deemed To Include Cost Of Following:- ( I ) Capacity Of Alternator At 9500 Feet Altitute 100 Kva, Ac 3 Phase, 415 Volts, 50 Hz. And As Recommended By The Manufacturer For Above Sized Dg Set . ( Ii ) Pcc Platform As Per Manufacter Design . ( Iii ) Engine And Alternator Shall Be Assembled On Common Steel Frame By The Manufacturer Itself And Not By Rep / Authorised Agent / Sister Concern Etc. ( Iv ) Engine Shall Be Designed Keeping In Consideration Of De-Rating Factor For 9500 Feet Altitute. ( V ) Installation, Testing And Commissioning Of Gen Set Shall Be Done In Presence Of MaufacturerS Engineer And Not By Any Authorised Person. ( Vi ) Dg Set To Be Tested For 12 Hrs Contineously As Following. All Testing Materials And Fuel To Be Provided By The Contractor. No Load = 15 Minutes, 25% Of Rated Load = 30 Minutes, 50% Of Rated Load = 30 Minutes, 75% Of Rated Load = 30 Minutes, Full Load = 4 Hr, 110% On Rated Load = 30 Minutes, Full Load = 4 Hr, 75% Of Rated Load = 30 Minutes, 50% Of Rated Load = 30 Minutes, 25% Of Rated Load = 30 Minutes, No Load = 15 Minutes. ( Vii ) Contractor Shall Produced A Copy Of Approved Certificate To Authenticate The Above From The Oem / De 125 Central Heating System Works 126 Design, Supply, Installation , Commissioning And Testing Of Central Heating Plant Using Oil Fired Glycol Based Hot Water Generator ( Kerosene / Hsd Oil As Fuel ) Suitable For Operation At 50Hz, Three Phase 4 Wire, 433 / 230 Volts, Ac Supply, Complete For Maintaining The Temperature Inside The Building At 22°C± 2°C During Winter For The Buildings At S No 2.01 ( One Block ) . The Temperature Should Be Maintained At Haws, Sonamarg, Srinagar As Per The Data Sheet Given In Particular Specifications At Ambient Temperature Upto The ( - ) 18°C At The Height Of 9500 Feet ( Approx ) Above Msl . 127 Chs Plant Should Comprise Of Boilers ( 2 Working + 1 Stand By ) , Glycol Solution Circulation Centrifugal Pumps ( 2 Working + 1 Stand By ) , Glycol Solution Make Up Centrifugal Pumps ( 2 Working + 1 Stand By ) , Flue Gas Exhaust Pipe Connected To Chimney As Per Cpcb Norms ( 01 Nos With Each Boiler ) , Expansion Tank, Glycol Fluid Tank, Underground Bulk Oil Storage Tank ( Not Less Than 10 Kl ) , Day Oil Storage Tank ( Not Less Than 990 Ltrs ) , Transfer Gear Oil Pumps Kerocine Oil ( 1 Working + 1 Stand By ) , Kerosene / Hsd Oil Piping Of Suitable Size With Necessary Accessories, Hot Glycol Fluid Piping Of Suitable Size With Suitable Insulation And Necessary Accrssoires, Suitable Valves, Wall Mounted Fcus With Remote Control, Wall Mounted Towel Radiators In Each Toilets, 1St Fill Of Glycol Charge ( The Mixture Of Water And Glycol Shall Have Freezing Temperature Of -25 Deg C ) , Lt Panel With Necessary Safety Control System With All Accessoires Including All Necessory Electric Connection With The Equipment ( Cables Shall Run In Cable Tray Of Suitable Size ) , Danger Notice Plate, “ No Smoking And “ Flammable” Sign Board As Per Requirement Of Petroleum Rules And Ccoe Nagpur ) And All Other Necessary Items.Note : All The Equipment & Accessories Should Be As Per Appropriate Codel Provisions. 128 Notes :The Rates Quoted By The Tenderer For The Work Deemed To Include The Provision Of Following :- ( I ) Pcc / Rcc Foundation For Chimney, Pumps, Boilers, Tanks And Other Equipments As Specified By The Oem. ( Ii ) Submission Of Whole Scheme Of Chs Including Boiler And Pumps Capacity Design, Fcus Capacity Design, Piping Design From Plant To The Rooms For Circulation Of Glycol Mixture And Technical Specification Duly Vetted By Iit ( Not By Professor In His Individual Capacity ) Within 90 Days Form Date Of Commencement Of Work For Approval Of Accepting Officer. The Invoice Of The Payment Made To Institute For Vetting The Whole Scheme To Be Submitted To The Department. ( Iii ) All The Electric Panels Should Be As Per Suitable Ingress Portection Code And Cpri Approved. All The Equipment & Accessories Should Be As Per Appropriate Codal Provisions. ( Iv ) All The Miscellenous And Other Items, If Any Required, As Per OemS Design. 129 Refrigeration And Air Conditioning 130 Supply And Fix Refrigerator, Electric Driven ( Single Phase ) , Capacity Upto 195 Litre, Bee Star Rated And Inverter Based Technology Comprising Of Following Specifiications / Requirements Or Superior Or Updated Version If Any: - ( A ) Type Of Cooling : Direct Cool ( B ) Gross Capacity ( Ltrs ) : 195 Litre ( C ) Net Capacity ( Litre ) : 188 Litre ( D ) Star Rating : 5 Star ( E ) Door Finish : Glass ( F ) Compressor : Inverter Based ( G ) Refrigerant : R600a 131 Supply And Fix Voltage Stabilizer For Automatic Operation, Single Phase Naturally Air Cooled Indoor Type & Designed For Input Variation Between 130 V To 290 V With Output Voltage Stabilized At 230 V With Accuracy Of ± 2.5% And Of Capacity 1 Kva Complete All As Specified And Directed. 132 Suppl;Ly, Installation, Commissioning Of Glass Top Deep Freezer, Single Phase, 220-260 Volt, 50Hz, Capacity 205 / 220 Litre Comprising Of Following Specifications / Requirements Or Superior Or Updated Version If Any: - ( A ) Type Of Chest / Freezer : Horizontal Glass Top ( B ) Door Type : Toughened Glass With Low Emissivity For Optimum Cooling Loss ( C ) Insulating Material : 60Mm Thick Polyurathane Foam ( D ) No. Of Doors : 2 ( E ) Refrigerant : R134a ( F ) Power Supply For Operation : 220-260Volt, 50Hz, Ac ( G ) Insulation System : Cfc Free Enviornment Friendly Insulation Material With Uv Grade Plastic Material For Long Lasting. ( H ) Stucco Aluminium Inner Liners For Better Hygiene ( J ) Castor Wheels For Easy Movements. 133 Schedule A Part-Xiii ( Manning And Operation Of Chs ) 134 Outsourcing Of Services For First Winnter Season After Completion Of Phase-I For Manning And Operation Of Chs Plant Of Otm Accn For 47 Men At Sonamarg By Deploying One Operator In Each Shift ( Each Shift Of 08 Hours ) In Three Shift I.E Round The Clock Including Sundays And Holidays Complete, In Reliable, Safe & Efficient Operating Conditions Throughqualified And Experienced Operators For The Chs After Completion Of Phase-I Work As Specified And Directed By Engineer-In-Charge.Notes : ( I ) Operator Will Operate Chs And Ensure Proper Functioning Of Chs. ( Ii ) The Operator Will Not Leave Theduty Place Without Permission. ( Iii ) Any Minor Repairs Required Will Be Done After Informing The Department. ( Iv ) Outsorcing Staff Will Change After Every 11 Months. ( V ) Daily Brooming, Sweeping And Removing Cobweb Inside The Plant Room And Surrounding Of Chs Plant Room. 135 ( Vi ) Daily Logsheet Of Installation In Proper Format Duly Filled By The Attendent, Printed Log Sheets And Other Related Documents Should Be Provided By Contractor. ( Vii ) Chs Operator Should Possess Minimum Iti Technical Qualification. ( Viii ) The Duty Staff Will Maintain The Premises Clean And Tidy Will Report Breakdown Or Any Other Related Doc Should Be Provided By Contractor. ( Ix ) Regular Cleaning Of Equiptment / Machinery As Specified And Directed. ( X ) The Required T&P And Safety Measure Shall Be Provided By The Contractor Incl Cost Of The Uniform Is Deemed To Be Included In The Quoted Rate. ( Xi ) Chs Will Run Only On Winter Season As Per Work Order For Phase-Ii Placed By Ge 136 Outsourcing Of Services For Second Winnter Season After Completion Of Phase-I For Manning And Operation Of Chs Plant Of Otm Accn For 47 Men At Sonamarg By Deploying One Operator In Each Shift ( Each Shift Of 08 Hours ) In Three Shift I.E Round The Clock Including Sundays And Holidays Complete, In Reliable, Safe & Efficient Operating Conditions Throughqualified And Experienced Operators For The Chs After Completion Of Phase-I Work As Specified And Directed By Engineer-In-Charge.Notes : ( I ) Operator Will Operate Chs And Ensure Proper Functioning Of Chs. ( Ii ) The Operator Will Not Leave Theduty Place Without Permission. ( Iii ) Any Minor Repairs Required Will Be Done After Informing The Department. ( Iv ) Outsorcing Staff Will Change After Every 11 Months. ( V ) Daily Brooming, Sweeping And Removing Cobweb Inside The Plant Room And Surrounding Of Chs Plant Room. ( Vi ) Daily Logsheet Of Installation In Proper Format Duly Filled By The Attendent, Printed Log Sheets And Other Related Documents Should Be Provided By Contractor. 137 ( Vii ) Chs Operator Should Possess Minimum Iti Technical Qualification. ( Viii ) The Duty Staff Will Maintain The Premises Clean And Tidy Will Report Breakdown Or Any Other Related Doc Should Be Provided By Contractor. ( Ix ) Regular Cleaning Of Equiptment / Machinery As Specified And Directed. ( X ) The Required T&P And Safety Measure Shall Be Provided By The Contractor Incl Cost Of The Uniform Is Deemed To Be Included In The Quoted Rate. ( Xi ) Chs Will Run Only On Winter Season As Per Work Order For Phase-Ii Placed By Ge

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 28-Sep-2022 CorrigendumNo01part3 Other 12-11-2022
2 28-Sep-2022 CorrigendumNo01part2 Other 12-11-2022
3 28-Sep-2022 CorrigendumNo01 Other 12-11-2022
4 31-Oct-2022 CorrigendumNo01 Date 21-11-2022
5 02-Nov-2022 Corrigendum No 2 Other 21-11-2022
6 03-Nov-2022 CorrigendumNo04 Other 21-11-2022
7 03-Nov-2022 Corrigendum03 BOQ 21-11-2022
8 04-Nov-2022 Corrigendum No 05 Other 21-11-2022
9 05-Nov-2022 Corrigendum No 06 Other 21-11-2022
10 21-Nov-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 28-11-2022

Key Value

Document Fees
INR 3000 /-
EMD
INR 625000.0 /-
Tender Value
INR 6 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail