| 1 | Taking downUn-Serviceablepoint wiring of Aluminium on batten/surface conduit/concealed conduit wiring(light/Fan/socket/call bell/ Power ) complete includingfixture and fittingssuch as switches, ceiling roses, shades, sockets, holders, light fittings andcall bells etc ) removingmaterials to store for taking credit after completion of work (Credit for above items should be made asper conditions separately) and making good thedisturbed surfaces of walls/floors/ ceilings etc. complete all as specified anddirected. |
| 2 | M&L for point wiring with multi - stranded FRLS copper conductor 1.5 Sqmm size nominal area PVC insulated unsheathed cable 1100 volts grade conforming to IS:694 drawn in and including FRLS PVC rigid conduit withnew sunk in pressed steel terminal boxes of 1.6 mm thick size or plastic gang box as per site requirement and providing new 3mm thick plastic laminated sheet cover of required colour fixed with brass screws and cup washers including single core stranded copper conductor 1.5 Sqmm PVC insulated unsheathed FRLS cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same conduit all as specified and directedfor one light/fan/exhaust fan/call bell point controlled by one switch complete all as specified anddirected.Note : Red/Blue/Yellow for phase, black for Neutral and Green for Earth. |
| 3 | All as per item No. 2above but for one three pin socket outlet 5 Amps, on independent Board complete all as specified anddirected. |
| 4 | All as per item No. 2above but for one three pin socket outlet 5 Amps on the same Board complete all as specified anddirected. |
| 5 | All as per item No. 2abovebut for one three pin socket outlet 5 Amps on the below Board complete all as specified anddirected. |
| 6 | All as per item No. 2 above but for one 3 pin socket outlet 15 amps independent with cable 2.5 Sqmm complete all as specified anddirected. |
| 7 | All as per item No. 2 above but for one light point controlled by two 2 way switches complete all as specified anddirected. |
| 8 | M&L for point wiring with multi - stranded FRLS copper conductor 1.5 Sqmm size nominal area PVC insulated unsheathed cable 1100 volts grade conforming to IS:694 drawn in and including PVC Casing caping withnew sunk in pressed steel terminal boxes of 1.6 mm thick size or plastic gang box as per site requirement and providing new 3mm thick plastic laminated sheet cover of required colour fixed with brass screws and cup washers including single core stranded copper conductor 1.5 Sqmm PVC insulated unsheathed FRLS cable as earth wire to common earth and connected to earth dolly and earth terminal box drawn in same conduit all as specified and directed for one light/fan/exhaust fan/call bell point controlled by one switch complete all as specified anddirected.Note : Red/Blue/Yellow for phase, black for Neutral and Green for Earth. |
| 9 | All as per item No. 8above but one three pin socket outlet 5 Amps, on independent Board complete all as specified anddirected. |
| 10 | All as per item No. 8 above but one three pin socket outlet 5 Amps on the same Board complete all as specified anddirected. |
| 11 | All as per item No. 8 above but one three pin socket outlet 5 Amps on the below Board complete all as specified anddirected. |
| 12 | All as per item No. 8 above but one 3 pin socket outlet 15 amps independent with cable 2.5 Sqmm complete all as specified anddirected. |
| 13 | All as per item No. 8 above one light point controlled by two 2 way switches complete all as specified anddirected. |
| 14 | S&F Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified anddirected. |
| 15 | M&L for sub main wiringwith 3 run of 6 sq mm for phases, neutral and earth usingsingle core multistranded copper conductor as per IS 694 PVC (FRLS) insulated, unsheathed ,multistrandard copper conductor drawn in and including FRLS PVC Casing caping/ rigid PVC conduit as per site reuirement with all accessories etc and earth conductor connected to common earth dolly including taking out old unsv aluminium / copper wiring complete all as specified and directed. Note: 3 run of 6 Sqmm and one run of earth wire shall be measured as one unit |
| 16 | All as per Item No. 15 but for 4 sqmm cable complete all as specified anddirected. |
| 17 | All as per item No. 15 but for 1.5 Sqmm cable complete all as specified anddirected. |
| 18 | Supply and FixingSwitch flush type, 5 Amps, single pole, one way and connection complete all as specified anddirected. |
| 19 | Supply and Fixing Switch Socket combination, 2 in 1, 3 pin 5 & 15 Amps (6 pin) flush typeand connection complete all as specified anddirected. |
| 20 | Supply and Fixing SwitchSocket combination, 3/2 pin 5Ampsflush type and connection complete all as specified anddirected. |
| 21 | Supply and Fixing Ceiling Rose Surface Poly carbonate type 65 x 50 mm three terminals and connection complete all as specified anddirected. |
| 22 | Supply and fixingBell push, flush type, 5 Amps, single pole.and connection complete all as specified anddirected. |
| 23 | Supply and fixingBell,AC, Ding Dong type 230 Volt. complete all as specified anddirected. |
| 24 | Supply & Fixing Regulator, Electronic step type,suitable for Ceiling fan and connection complete all as specified and directed. |
| 25 | Supply & FixingRegulator dimmer type, switch type,suitable for Ceiling fan and connection complete all as specified and directed. |
| 26 | Supply & Fixing in repairs Regulator, Modular, Electronic Step type 2 module and connection complete all as specified and directed. |
| 27 | Supply & Fixing in repairs Modular type Switch single pole 6 Amps one way 1 Module and connection complete all as specified and directed. |
| 28 | Supply & Fixingin repairs Modular type Switch single pole 6 Amps Two way 1 module and connection complete all as specified and directed. |
| 29 | Supply & Fixing in repair Modular type Switch single pole 16 Amps one way 1 module and connection complete all as specified and directed. |
| 30 | Supply & Fixing in repair Modular type socket out let 2 in 1, 6/16 Amps 2 module and connection complete all as specified and directed. |
| 31 | Supply & Fixing in repair Modular type Socket out let 6 Amps 2 module and connection complete all as specified and directed. |
| 32 | Supply and fixing modular white cover plate with frame 1 Module complete all as specified and directed. |
| 33 | Supply and fixing modular white cover plate with frame 2 Module complete all as specified and directed. |
| 34 | Supply and fixing modular white cover plate with frame 3 Module complete all as specified and directed. |
| 35 | Supply and fixing modular white cover plate with frame 4 Module complete all as specified and directed. |
| 36 | Supply and fixing modular white cover plate with frame 6 Module complete all as specified and directed. |
| 37 | Supply and fixing modular white cover plate with frame 8 Module complete all as specified and directed. |
| 38 | S&F in repairs, Single pole and neutral sheet metal enclosure with two pin and earth plug and socket complete with one single pole MCB 16/20 Amps all as specified and directed. |
| 39 | S&F Sheet metal repair enclosure for DB\"s double glazed door IP-43 Single pole & neutral 240 V, 8 way with cable end box conforming to IS-8623-1 & 3, IEC 61439-1 &3 made in CRCA sheet steel, RAL 9003 powder coated ready to use DB\"s provided with 100 A insulated phase bus bar, neutral bar with shrouds, earth bar, sticking saddles, cement spill protector, colour coded interconnection wire set, cable ties, blanking plates and circuit identification label with provision for DP MCB as incomer and SP MCBs as outgoing complete all as specified and directed. |
| 40 | S&F Sheet metal repair enclosure for DB\"s double glazed door IP-43 Vertical Triple pole & neutral 415 V, 4 way with cable end box conforming to IS-8623-1 & 3, IEC 61439-1 &3 made in CRCA sheet steel, RAL 9003 powder coated ready to use DB\"s provided with insulated vertical phase bus bar, neutral bar with shrouds, earth bar, sticking saddles, cement spill protector, colour coded interconnection wire set, cable ties, blanking plates and circuit identification label with provision for 3/4 pole MCCB as incomer and SP/TP MCBas outgoings complete all as specified and directed.. |
| 41 | S&F singlepole MCB 6 to 16 Amps 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 15 KA breaking capacity conforms to IS/IEC 60947-2 and terminal box suitable upto 35 sqmm cable complete all as specifed and directed. |
| 42 | S&F DP MCB 32 Amps 240 v, 50 Hz AC Made from moulded self-extinguishing thermostat plastic and suitable for ‘C’ curve, 15 KA breaking capacity conforms to IS/IEC 60947-2 and terminal box suitable upto 35 sqmm cable complete all as specifed and directed. |
| 43 | Supply and Fixing in repairs, Miniature circuit Breakers, C curve Triple pole & neutral, 415 Volts of capacity (40 to 63 Amps) as ordered breaking capacity 10 KA complete all as specified and directed. |
| 44 | Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type with driver, holder includingLED tube light connecting up with three core flexiblecopper conductor cable of suitable size from ceiling rose complete all as specified and directed. |
| 45 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 46 | Supply & Fixing in repairs 20 watt T-8 linear lamp with PC housing for optimum light output, specially designed diffuser to avoid direct view of LEDs complete all as specified and directed. Make /Model : CatPart No. LL13-181-65SE of make Wipro or equivalent in Philips/GE. |
| 47 | Supply & Fixing in repairs 18 watt T-5 linear lamp with PC housing for optimum light output, specially designed diffuser to avoid direct view of LEDs complete all as specified and directed. Make /Model : CatPart No. LL13-181-65-T5 of make Wipro or equivalent in Philips/GE. |
| 48 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed. |
| 49 | Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size completecomplete all as specified and directed. |
| 50 | Supply and fixing in repairs 30 watt 4 feet linear suspended luminaire, housing made of extruded aluminium with satin finish PMMA diffuser for standalone and seamless end to end connectivity including suspension complete all as specified and directed. Make /Model : LM31-401-XXX-57WCG1 of make Wipro or equivalent make in list of manufactures |
| 51 | S&F LED bulb 7 watt complete all as specified and directed. |
| 52 | S&F LED Light fitting 1 x 9 W/ 10 W bulkhead luminaire including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. |
| 53 | Taking down the geyser of any capacitydeposting to MES store yard for repair and refixing the same after repair at desired location complete all as specifed and directed.Note : Repairshall be measured separatly under relevant item of Sch \"A\". |
| 54 | Supply and fix copper body inner shell Suitable for 25 Ltr capacity including taking out old unsv steel / copper tank complete all as specified and directed. |
| 55 | M&L painting with two coats of synthetic enamel paint over a coat of red oxide primer to Geyser of any capapcity and writing the MES No after preparing the old painted surfaces by scraping, rubbing and cleaning the dust,rust existing painting fixing bends, bents, etc. including suitable new 02 x rubber gasket complete all as specified and directed . |
| 56 | M&L Glass wool packing required quantity for cover the 25 Ltr /50 Ltr copper shell to avoide the heat conduction including taking out oldall as specified and directed. |
| 57 | Supplyand fix outer body of water storage heater (Geyser) suitable for 25 Ltr capacity complete all as specified and directed. |
| 58 | Supply and fixing heating coil 1500 w in existing geyser of any type round/triangular complete including taking out old heating coil all as specified and directed. Make : Micron/Havell\"s/Theeta |
| 59 | Supply and fixing heating coil 2000W in existing geyser of any type round/triangular complete including taking out old heating coil complete all as specified and directed.Make : Micron/Havell\"s/Theeta |
| 60 | Supply and fixing thermostat range of 30 - 80 degree. As per site requirement. Make: Bajaj/Racold/ V star /Havells |
| 61 | Supply and fixingNon Return Valve brass suitable 15 mm size including taking out old unsv NRV complete all as specified and directed. |
| 62 | S&F steel pipe connection 45 cm long both end brass suitable for hot water supply and screw down 15 mm GI pipe complete all as per specified and directed. Make:- Prayag/ Supreme/ SFMC |
| 63 | S&F PVC connection pipe 45 cm long both end long both end brass nut suitable for cold water supply and screw down 15 mm GI pipe completeall as per specified and directed Make:- Prayag/ Supreme/ SFMC |
| 64 | S&F indicator lamp red/green colour suitable for storagewater heater (geyser) 25 lit/50 lit. capacity complete all as specified and directed |
| 65 | Supply and laying of CPVC pipes outer diameter 16 mm SDR 11 & plain CPVC SDR 11 fittings on walls / ceiling or laying in floors complete all as specified and directed. |
| 66 | S&F stop valves 15 mmfancy type chromium plated with long shank and cup screwed down high pressure with crutch or butterfly handle, screwed both ends for iron pipe complete all as specified and directed. |
| 67 | Supply and fixing in repair 15 mm bib taps fancy type, cast copper alloy with crutch or butterfly hadle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 68 | M&L for new Grouting of 12 X 100 MM bolt in stone bricks masonary wallwith 1:4 CM for Geyser all as specified and directed |
| 69 | S&F geyser base plate front and rear suitable for existing Geyser complete all as specified and directed. |
| 70 | S&F plug top 15 amp switch having brass screw complete all as secified and directed. |
| 71 | Supply and fix metal clad plug and socket suitable for 20 amps complete all as specified and directed . Make :L & T/Siemens/Schneider |
| 72 | Taking down the ceiling and Exhaust fan of any make /model andsizefrom its original location, sealing cable end, dismantling the blades and removing fan and blades to store complete all as specified and directed |
| 73 | Hanging only ceiling fan and connecting up including provision of cable from ceiling rose or connector to fan complete all as specified and directed |
| 74 | Supply and Fixing in repairs bearing of exhaust fan of size/300/380/450 mm sweep all as specified and directed. |
| 75 | Supply and Fixing in repairs bearing of Ceiling fan of size 1200/1400 mm sweep all as specified and directed. |
| 76 | Supply and Fixing in repairs clamps with rubber bush, safety pins, nuts and bolts suitable for ceiling fan all as specified and directed. |
| 77 | M/L for rewinding the Ceiling fan motor with supper enamelled copper winding wire of same gauge and weight, varnishing, drying and insulating with new insulating materials completeall as required and directed forceiling fan of size1200 /1400mm sweep , single phase 230 volts AC all as specified and directed. Make of Winding Wire Any ISI Marked |
| 78 | M/L for rewinding the exhaust fan motor with supper enamelled copper winding wire of same gauge and weight, varnishing, drying and insulating with new insulating materials completeall as required and directed for exhaust fan 300/380/450 mm sweep single phase 230 volts AC all as specified and directed.Make of Winding Wire Any ISI Marked |
| 79 | M&L for spray painting of Ceiling fan of size 1200/1400 mm sweep with two coats of synthetic enamel paint of approved colour after removing the dirt/scales and preparation of the old painted surface of fan blades, motor and down rods complete all as specified anddirected. |
| 80 | Fixing only exhaust fan and connecting up including provision of cable from ceiling rose/connector to fan Complete all as specified and directed . |
| 81 | S&F in repairs, capacitors of capacity 3.15 mfdall specified and directed. |
| 82 | S & F in repairs Ceiling Fan canopies (Top & Bottom) suitable for fixing 1200/1400 mm sweep Complete all as specified and directed . |
| 83 | S & Fin repairs Ceiling fan down rods30-45 CMsuitable forfixing 1400/1200 mm sweep fanwith required Bolts and Nuts Complete all as specified and directed . |
| 84 | Taking down the unserviceable bldg security light fitting of any type (HPSV.HPMV,CFL,Tube light/Metal Halide fitttings )/wattage from its original location by unscrewing the nuts,bolts,washers etc and making good the disturbed surfaces complete all as specified and directed. |
| 85 | Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 86 | M & L for bracket made out of GI tubing 40mm dia,light grade 1.2 mtr long including fixing withMS clamps -2 Nos made out of 50 mm wide 5mm thick flat iron with M.S nuts bolts 75 mm long 12 mm dia-4 Nos with flat washer (3mm thick) -02 No for each including painting with aluminium paint over one coat of red oxide to the M.S clamps & bracket etc Complete all as specified and directed |
| 87 | Replacement of sealed unit compressor for water cooler of capacity 40/80 litres company fabricated including first fill of refrigerent gas,jointing,leak testing and commisioning complete all as specified and as directed. |
| 88 | All as per item No. 87 above but for Compressor( Refrigerator 310 Ltr) complete all as specified and directed |
| 89 | All as per item No.87 above but for compressor of split AC of capacity 2 ton complete all as specified and directed |
| 90 | All as per item No. 87 above but for Compressor ofsplit AC of capacity 1.5 ton complete all as specified and directed. |
| 91 | All as per item No. 87 above but for Compressor of split AC of capacity 1 ton complete all as specified and directed. |
| 92 | Replacement of fan motor 230 volts50 Hz and testig the motor for 1/8 HP (Suitable for Water cooler) complete all as specified and directed (Make: OEM) |
| 93 | All as per item No. 92 above but for 1/6 HP(Suitable for 2 Ton AC) complete all as specified and directed |
| 94 | All as per item No. 92 above but for 1/4 HP(Suitable for 1.5 Ton AC) complete all as specified and directed |
| 95 | Replacement of PCB (printed circuit board ) units as existing model/make for split AC 1.5/2 Ton capacity complete all as specified and directed. Make: LG |
| 96 | S & F AC contactor MP-11 suitable for split AC 1.0/1.5/ 2 TR ,240 volts 50 Hz, single phase, including taking down old AC contector MP-11 complete all as specified and directed . |
| 97 | M & L float valve PVC ISI mark size 15 mm,with ball cock rod suitable for any capacity water coolerand any make including complete all as specified and directed. |
| 98 | M & Lsuction valve/liquid valveof size 1/2\" &1/4\" along with dead nut suitable for of Split AC 1.5Ton capacity out door unit including taking out od old unsv valve complete all as specified and directed.(Make:OEM) |
| 99 | M & LRefrigerator Lamp/bulb 310Ltrs/286ltrs/165 ltrs, lamp thread and pin type,15 volts, 240 volts 50 Hz, single phase including taking down old Lamp complete all as specified and directed . |
| 100 | M & Lsuction valve/liquid valveof size 3/8\" & 5/8\" along with dead nut suitable for of Split AC 2 Ton capacity out door unit including taking out od old unsv valve complete all as specified and directed. |
| 101 | Replacement of defective / demaged transformer for voltage stabilizer of 5 KVAcomplete all as specified and directed. |
| 102 | All as per item No. 101 above but for 4 KVA complete all as specified and directed |
| 103 | Replacement of blower moter 230 volt ,50 Hz for 1/20 HP ( Water cooler 40/80 ltr) complete all as specified and directed .(Make:OEM) |
| 104 | All as per item No. 103 above but for 1/100 HP for split AC & deep Freezer complete all as specified and directed |
| 105 | All as per item No. 103 above but for 1/10 HPfor split AC complete all as specified and directed |
| 106 | Refilling of refrigerent gas R22/R32/R-410 in sealed unit compressor of split AC of any capacity including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed . |
| 107 | Re filling of refrigerent gas ( R 134A) in sealed unit compressor refrigerator of any capacity including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed . |
| 108 | Refilling of refrigerent gas (R 134) in sealed unit compressor of water cooler of any capacity including breezing, jointing,leak testing ,commissioning,taking down and refixing complete all as specified and directed . |
| 109 | Taking down carefully water cooler of any make/model after repair refixing of sameor other position or depositing in MES store of AGE (I) Agrani complete all as specified and directed. |
| 110 | All as per item No. 109 above but Window AC/ split AC complete all as specified and directed |
| 111 | All as per item No. 109 above but refrigerator complete all as specified and directed |
| 112 | All as per item No. 109 above but deep freezer complete all as specified and directed |
| 113 | Servicing of Split AC of any make and capacity including pressure testing, cleaning of inddor unit with blower and outdoor unit, washing, filter cleaning, copper tubing check complete all as specified |
| 114 | S & F of Running capacitor of capacity 50 MFD, any type and any make including taking down old unsv capacitor complete all as specified and directed. |
| 115 | All as per item No. 114 above but 36 MFD complete all as specified and directed |
| 116 | All as per item No. 114 above but 25 MFD complete all as specified and directed |
| 117 | All as per item No. 114 above but 15 MFD complete all as specified and directed |
| 118 | All as per item No. 114 above but 10 MFD complete all as specified and directed |
| 119 | All as per item No. 114 above but 6 MFD complete all as specified and directed |
| 120 | All as per item No. 114 above but 4 MFD complete all as specified and directed |
| 121 | All as per item No. 114 above but 2/2.5 MFD complete all as specified and directed |
| 122 | S&F relay suitable for 1.5 / 2 Ton capacity AC, any type and any make including taking down Relay. |
| 123 | S&F Self-closing taps cast copper alloy chro-mium plated screwed for iron pipe and fixed 15mm dia for water coolerany type and any make including taking downof old bib cock complete all as specified and directed. |
| 124 | S&F Thermostat for water cooler of,any type and any make anyb capacity ,including taking down Thermostat complete all as specified and directed. |
| 125 | S&F Over load protector for water cooler,any type and any make including taking down Over load protector complete all as specified and directed. |
| 126 | Supplyinstallation and testing copper tubing of size 1/2\" &1/4\" along with sleeve insulation and cable PVC 4 Sqmm three core copper flexible conductor complete all as specified and directed .. |
| 127 | M & L for out door unit stand suitable for split AC 1.5/2 Ton capacity incl PCC work and fixing arrengment complete all as directed. |
| 128 | Dismantling of fan motorin water cooler/Desert cooler of 1/8 HP capacity and removing the burnt coil ,rewinding of motor with supper enemaled copper wire of suitable size & gauge incl replacement of bearing of blower motor and cleaning properly ,the slot winding greasing of bearing etc , and reflxing testing complete all as specified and directed. |
| 129 | Dismantling of fan motor of AC of 1.5 Ton ,1/4 HP capacity and removing the burnt coil ,rewinding of motor with supper enemaled copper wire of suitable size & gauge incl replacement of bearing of blower motor and cleaning properly ,the slot winding greasing of bearing etc , and reflxing testing complete all as specified and directed. |
| 130 | Dismantling of fan motor of AC of2 Ton ,1/6 HP capacity and removing the burnt coil ,rewinding of motor with supper enemaled copper wire of suitable size & gauge incl replacement of braring of blower motor and cleaning properly ,the slot winding greasing of bearing etc , and reflxing testing complete all as specified and directed. |
| 131 | S&F relay for water cooler of,any type and any make anyb capacity ,including taking down Thermostat complete all as specified and directed. |
| 132 | S & F for air filter suitable for 1.5/2 Tonsplit AC as per existing size complete all as specified and directed. |
| 133 | S&F nitrile rubber thermal insulation over copper tubing any of size complete all as specified and directed . |
| 134 | S&F swing motor of split AC of capacity 1.5 / 2.0 Ton, complete all as specified and directed. Make: LG |
| 135 | S&F remote control of split AC of capacity 1.5 / 2.0 Ton, complete all as specified and directed . |
| 136 | S&F water tray of split AC of capacity 1.5 / 2.0 Ton, complete all as specified and directed. |
| 137 | S & F Freezer /Cooling coil for refrigerator with freezer door ,of any make/model all as specified and directed complet all as specified and directed. |
| 138 | S&F in repair heavy duty metallic filter of make Aquaguard in existing water cooler complete all as specified and directed . |
| 139 | S&F cartiagefilter elementfor water cooler of make Aquaguard complete all as specified and directed. |
| 140 | Repair of doemstic RO filter of make Aqua gurad includingAC block, PCB Board, Solenoid valve with coil, UV lamp, Compressor with Assly, thermostat complete all as specified and directed.Note : (a) Repair shall be done through OEM only (b) Payment shall be made only after submission of necessary completion certificate issued by OEM) |
| 141 | Repair of water cooler with inbuilt Water Doctor cooler including PF candles, AC block, PCB Board, Solenoid valve with coil, UV lamp, Compressor with Assly, thermostat complete all as specified and directed.Note : (a) Repair shall be done through OEM only (b) Payment shall be made only after submission of necessary completion certificate issued by OEM) |
| 142 | Supply and fixing indoor plate suitable for hanging the split AC indoor of 1.5 /2 Ton complete all as specified and directed. |
| 143 | Supply and fixing flower nut of sizes 1/2\", 1/4\", 5/8, 3/8\"suitable for split AC of any capacity complete all as specified and directed. |