}

Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Alhilal Mil Stn, Kangra-Himachal Pradesh

Military Engineer Services-MES has published Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Alhilal Mil Stn. Submission Date for this Tender is 17-10-2022. Power Factor Panel Tenders in Kangra Himachal Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

34007960
Corrigendum : Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Alhilal Mil Stn
Indian
Himachal Pradesh
Kangra
17-10-2022

Tender Details

Repair Maintenance And Replacement Of Lt And Apfc Panels, Switchgears, Service Cables And Misc Works At Alhilal Mil Stn

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 10-Oct-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 17-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 20000.0 /-
Tender Value
Refer document

BOQ Items

Name of Work: REPAIR/MAINTENANCE AND REPLACEMENT OF LT AND APFC PANELS, SWITCHGEARS, SERVICE CABLES AND MISC WORKS AT ALHILAL MIL STN
Sl. No. Item Description
1Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundation etc or for laying of cables, errection of poles, struts / stays etc including taking out cable cover or stone slab, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and directed.
2Returning filling in including spreading leveling watering and well ramming inlayers not exceeding 25 cm in any type of soil complete all as specified and directed.
3Removing excavated any type of soil to a distance not exceeding 50 m and depositing where directed, at a level not exceeding 1.5 m above the starting point complete all as specified and directed.
4M&L sand cushioning to undergound cable with using fine river sand and gently punning for cushioning to cable complete all as specified and as directed. Note:-for the purpose of payment only punned thickness will be measured.
5S&F 40mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
6S&F 50mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,,including taking out old tubing complete all as specified and as directed.
7S&F 80mm bore galvanised iron, light grade (ISI marked) laid in trenches / fixed on wall / poles etc for protection of cable,including taking out old tubing complete all as specified and as directed.
8M&L cement concrete (1:3:6) type C2 using 40mm graded crushed stone aggregates for foundation of poles / struts / stays etc including demolition of damaged foundation complete all as specified and directed.
9M&L PCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate for pedestal including necessary formwork and fair finishing to exposed surface without using extra cement including dismantling of damaged padestal complete all as specified and directed.
10Supply and fix in replacement Digital voltmeter in96x96 Sqmm three phase class 1.0including making necessary connection in existing panel complete all as specified and directed.
11Supply and fix in replacement Digitalammeterin96x96 Sqmm three phase class 1.0including making necessary connection in existing panel complete all as specified and directed.
12Supply and fix in replacementselector switch for voltmeter/ammeter including making necessary connection in existing panel complete all as specified and directed.
13Supply and fix in replacementneon indicator lamp with holder assembly RYB including making necessary connection in existing panel complete all as specified and directed.
14Supply and fix in replacementCT coil of existing capacity including making necessary connection in existing panel complete all as specified and directed.
15Cutting and removing existing wild grass, vegetation, creepers, small plants / bushes etc clamping up towards the poles and stays etc including cleaning bottom surface area of pole &stay not less than 1m x 1m by surface dressing of earth outside and inside substations, perimeter fencing around pump house area, and in drains surrounding area from site complete all as specified and directed.
16Supply and fix in replacement synthetic insulation mat 2m x 1m x 10mmcomplete all as specified and directed.
17M&L 25X20cm size HT danger notice plate of 1.60mm thick mild steel sheet,vitreous enamelled white,with letters,figures and conventional skull and bones in single red colour and fixed with M.S clamps,bolts and nutsincluding taking down existing rusted danger notice platecomplete all as specified and directed.
18Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 120sq.mm 3 1/2core complete all as specified and directed.
19Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 95sq.mm 3 1/2core complete all as directed.
20Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 70sq.mm 3 1/2core complete all as directed.
21Supply and laying or fixing or passing through pipe or laid in trenches, 1100 Volt grade heavy duty cable XLPE insulated,armoured electric cable with aluminium conductor ,cross-sectional area 50sq.mm 3 1/2core complete all as directed.
22M&L old size brick class "B" as in cable protection laid dry,flat,transversally along the length of cable on sand cushioning with width equalto length of the brickcomplete all as specified and as directed.
23Supply and fix in replacement MCCB,AC,415volts, 250 Amp, 35/36KA,4 pole, with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
24Supply and fix in replacement MCCB,AC,415volts, 160 Amp, 35/36KA,4 pole, with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
25Supply and fix in replacement MCCB,AC, 415volts, 125 Amp, 16KA, 4 pole,with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
26Supply and fix in replacement MCCB,AC, 415volts, 100 Amp, 16KA, 4 pole,with microprocessor release including making necessary connection in existing panel complete all as specified and directed.
27M&Lpreparation of existing old steel painted surface of panels by complete removal of paint of any size andany height , apply one coat of synthetic enamel paint inside and two coats on outside of panel (strictly existing shade) over a coat of red oxide zinc chrome primercomplete all as specified and directed.
28Taking down old un-serviceable panel of any type and size, Supply, install, testing & commissioning of CPRI approved powder coated LT panel board, outdoor type, floor mounted, factory made suitable for 415 volt, 3PH, 4 wire, 50 HZ, AC supply system having busbars chamber with copper bus bars400 Amps rating mounted on porcelain insulators. The panels shall be factory made, double door, made out of 3.15 mm thick MS Sheet (CRCA) totally enclosed dust, vermin & rust proof operated with front & rear opening with locking arrangement fixed with MS angle iron frame of size 40x40x6 mm mounted on angle iron legs made out of angle iron size 40mm x 40mm x 6mm , 1.0 mtr long, 0.50 mtr above ground level and 0.50 mtr embedded in PCC blocks (PCC 1:2:4 type B1) of size 0.30mtr x 0.30mtr x 0.50 mtr-04 nos including internal wiring with multistranded copper condutor cable of suitable size including lugs and cable gland to incoming and outgoing cable etc complete all as directedand comprising of the following :- (A) In Comming (i) MCCB four pole 415 volts AC supply 250 A thermal magnetic release type 35/36 KA-01 No(ii) Panel mounted degital multi function meter for measuring voltage(0-500) volts current (0-100 Amps) and frequency -01 No (iii) RYB neon indicating lamp (Set of three -01 No. (B) Out going : (i) MCCB four pole 415 volt 16 KA 125 Amp rating thermal magnetic relase type-04 Nos. (ii) MCCB four pole 415 volt 16 KA 63 Amp rating thermal magnetic relase type-01 Nos (iii) MCB SPN 240 volts 10 KA 20 Amp rating-02 Nos.
29Taking down old un-serviceable panel of any specification, Supply, installation, commissioning and testing powder coated LT feeder pillar box outdoor type of size 0.90mtr x 0.50mtr x 0.60 mtr factory fabricated made out of MS sheet of thickness 3.15 mm with front door openable with locking arrangement mounted on angle iron legs made out of angle iron size 40mm x 40mm x 6mm , 1.0 mtr long, 0.50 mtr above ground level and 0.50 mtr embedded in PCC blocks (PCC 1:2:4 type B1) of size 0.30mtr x 0.30mtr x 0.50 mtr-04 nos, with 200 Amp rated copper bus bar LED phase indicating lamp, suitable for 3 phase 4 wire supply system with MCCB 125 Amp 4 pole breaking capacity 25 KA-01 No, duly drilled holes for cable connection mounted on epoxy based post insulators all as required at site, complete all as specified and directed.
30M&Lwelding existing broken panel doors (any number of shutters) and welding good quality hinges (any size any number of hinges per panel) of suitable size for making open and close the panel doors including bends etc and fixing locking arrangement of the doors complete all as specified and directed.
31M&L Earthing complete with galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead strip 25mm x 4mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of MES SSR Part-I connected to main switch board or main control board all as specified and testing on completion including provision of earth strip protected by galvanized iron 40 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of soil, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc including taking out old un-serviceable earthing, complete all as directed by Engineer-in-charge. Note: (i) The concrete pit shall be PCC 1:3:6 type C-1, 40mm thick pre-cast cover slab of RCC (1:2:4) type B-1 using 20mm graded crushed stone aggregate, reinforced with 8mm TMT bars @ 10 cm c/c on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No. 3 of MES SSR Part-I., (ii) Item includes the cost of GI pipe up to 7.5m GI for protection of earth strip & (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
32M&Linspection, checking and repair of APFC panel by cleaning of dust inside with blower, cleaning of moving part/contract from CT cleaner, tightening of loose parts/electrical wiring , cleaning of contractors, relays and capacitor juction points, oiling of cooling fan , complete testing of APFC relay with necessary settings with CTs /load adjustments to match with the APFC load management systemcomplete with replacement of burnt/worn out unserviceable components /burnt wires thimbles /lugs etc for APFC panel capcity 50 KVAR to 150 KVAR completeall as specified and directed. Note : All unserviceable parts shall be measured and paid seprately as supply only. Replacment of small nuts/screws, wires lugs or thimbles and cleaning material cost included in this item.
33SupplyonlyMCB, TP 6 to 32 Amp 10 KA C curve for existing APFC panel complete all as specified and directed.
34SupplyonlyMCB, TP 40 to 63 Amp 10 KA C curve for existing APFC panel complete all as specified and directed.
35Supplyonly Auxillary contractor 1 NO+1NC TP 415 volts suitable for 10 KVAR ratingfor existing APFC panel complete all as specified and directed.
36Supplyonly Auxillary contractor 1 NO+1NC TP 415 volts suitable for 20 KVAR ratingfor existing APFC panel complete all as specified and directed.
37Supplyonly capacitor 440 volts 50 Hz5 KVARfor existing APFC panel complete all as specified and directed.
38Supplyonly capacitor 440 volts 50 Hz 10 KVARfor existing APFC panel complete all as specified and directed.
39Supplyonly capacitor 440 volts 50 Hz 15 KVARfor existing APFC panel complete all as specified and directed.
40Supplyonly capacitor 440 volts 50 Hz 20 KVARfor existing APFC panel complete all as specified and directed.
41Supplyonly CT"s suitable for Ampere meter 100/5A ratiofor existing APFC panel complete all as specified and directed.
42Supplyonly CT"s suitable for Ampere meter 200/5A ratiofor existing APFC panel complete all as specified and directed.
43Supplyonly APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 6 stagesfor existing APFC panel complete all as specified and directed.
44Supplyonly APFC relay square flush type with protection devices intelligent auto processor based on electronic controller unit 8 stagesfor existing APFC panel complete all as specified and directed.
45Supply only MCCB,AC,415volts,100 Amp, 25KA, 4 pole, fixed thermal magnetic release including making necessary connection in existing APFC panel complete all as specified and directed.
46Supply only MCCB,AC,415volts,160 Amp, 25KA, 4 pole, fixed thermal magnetic release including making necessary connection in existing APFC panel complete all as specified and directed.
47Taking out old underground/under pipe/above ground level LT XLPE/PVC cable of any size from trenches/wall/roof/below the road/pipe /pole/DB etc. including taking out brick layer and staking serviceable brick for reuse and remove broken bricks from site complete all as specified and directed.
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail