| 1 | Taking down old damaged SGSW/UPVC/RCCpipes from existing lines including necessary excavation as per requirement of old fitted in trenches & S&F 150 mm dia RCC NP3 pipe laid and jointed complete includingproviding 150 mm thick cement concrete (1:4:8) type D-2 using 40mm grade stone agg as in bed for pipes incl packing under and huaunching against the sides of pipes after they are laid tested complete all as specified and directed . |
| 2 | Taking down old damaged SGSW/UPVC/RCCpipes from existing lines including necessary excavation as per requirement of old fitted in trenches & S&F 200 mm dia RCC NP3 pipe laid and jointed complete includingproviding 150 mm thick cement concrete (1:4:8) type D-2 using 40mm grade stone agg as in bed for pipes incl packing under and huaunching against the sides of pipes after they are laid tested complete all as specified and directed . |
| 3 | Taking down old damaged SGSW pipes from existing lines including necessary excavation of old fitted in trenches & S&F UPVC underground drainage pipe (UDS) type \"B\"200mm dia with wall thickness 4mm (min) and pressured 4 KN /Mtr Sq jointed in cement solvent completeincluding providing cement concrete (1:4:8) type D-2 using 40mm grade stone agg as in bed for 200mm bore pipes incl packing under and huaunching against the sides of pipes after they are laid tested complete all as specified and directed . |
| 4 | All as per item srl No 03 above but 160 mm dia complete all as specified and directed . |
| 5 | Cutting into existing manholes for connecting new drains/ pipe of any dia, making good to pipe and making good of broken manhole. |
| 6 | M&L Cleaning of existing manhole and sewage pipe lines of anyinternal dia 100mm/150/160/200mm, any depth manually or through mechanical appliances and making sewer line functional blockage of bathroom/toilet kitchen by cleaning the Nahani traps/gully traps,blockage of WC Indian or European washing thoroughly grating of trap,CI waste pipes by opening the clearing eyes,removing all the mud/sludge and getting out including cleaning of SGSW or CI or UPVC pipes upto first manhole, Cleaning of CI pipes of any dia from first floor to ground floor upto trap and Ist manhole along the wall, floor at any depth inciuding manholes by removing the manhole covers of any type / size and cleaning by manually or through mechanical appliances asrequierd at site from manholes and well flushing with water after cleaning including getting out sludge if any and liquid materals from connecting manholesdeposited in sewar line removing the solids and sludge to anydistanceand reinstatingthe manhole cover to its original postion (cost of removal of sludge/liquid material from sewage lines and manholes in same line is incl. in rate of this item and rate quoted also includes for keeping particular sewage line which is undertaken once for cleaning, functional for full contract period) complete all as specified and directed by Engr-in-ChargeNote:- (a) Contractor/supervisor take complaint from JE concernedall day and ensure to resolve all complain. with in same day(b) Contractor shall make himself aquainted with the area & the complain received daily in general.No claim however shall be entertained in regard to any incorrect assesment or increase in complains due to unforescen reason. (c) All complains need to be cleared with in same day only.. |
| 7 | (d) No payment shall be made for Sundays & holidays. However department shall not give major work on these days and only major work requiringfull day job of one mazdoor is required than department shall allow leave on another day in compensation. No extra claim,however,shall be entertained in this regard. (e) Contractor will deploy sufficent mazdoor(skilled or unskilled) daily to attendday to day complaint as mentioned above.The details of the mazdoor shall be submitted by the contractor to GE through Engineer-in-Charge.Insurance of mazdoor within 15 days commencement of work along with insurance from Govt Agency.Mazdoor will reportdailyor as required to Supervisor who will distribute complain after takingJE incharge from Subdivisonat 0900 hrs and departafterattending all complaints. Incase of non attending complaints in same day ,recovery @250 per complaints will be recovered from contractor. (f) The contractor shall provide adequate tools,plants,clothing kit etc to rectify the complaints. (g) The sludge obtained during rectifying the complaints shall be deposited & dispose suitably all as specified and directed by Engr-in-Charge. |
| 8 | M&L Cleaning of existingseptic tank/soakage well/ manholes/ lines and de-sluding /de-watering of septic tank and soakage well of any size and depth by removing the manhole covers of any type / size and cleaning by means of hydraulic jet pressure/pumping machine asrequierd makingit fully functionalto the entire satisfaction of Engr -In- Charge at site, from manholes and well flushing with water after cleaning including getting out sludge if any and liquid materals from connecting manholesdeposited in sewar line removing the solids and sludge to anydistanceand reinstatingthe manhole cover to its oiginal postion (cost of removal of sludge/liquid material from sewage lines and manholes in same line is incl. in rate of this item and rate quoted also includes for keeping particular sewage line septic tank and soakage well which is undertaken once for cleaning, functional for full contract period) complete all as specified and directed. Note:- (a) The contractorshall bailout entire blocked sewage in septic tank,soakage well,line etc and all as directed by Engr-in-Charge.(b) Contractor shall make himself aquainted with the area & the complain received daily in general.No claim however shall be entertained in regard to any incorrect assesment or increase in complains due to unforescen reason. |
| 9 | (c) Contractor will deploy sufficent mazdoor(skilled or unskilled)to attend complaint as mentioned above. Incase of non attending complaints sufficent time as decided by Engr-in-Charge but not more than 3day ,recovery @ 1000 per day will be recovered from contractor. (d) The contractor shall provide adequate tools,pressure pump for cleaning blocked lines and pumping bailing out machine & storage tank for sludge.(e)The sludge obtained during rectifying the complaints shall be deposited & dispose suitably all as specified and directed by Engr-in-Charge. |
| 10 | M&L in repairs 100mm Cast iron floor trap, with SS grating including jointing to waste pipe fixed in cement type B-1 1: 2:4and making good wall or floor tiling to match existing surface. |
| 11 | All as per Item No. 10 above but 75mm |
| 12 | M&L 75mm CI Bends (any radius), with ovel acess door diminishing pieces or tapers (larger bore measured) |
| 13 | M&L 75mm CI Branch pieces, double (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches |
| 14 | M&L for 75 mm dia CI cross \"T\" doublejunction , (double T), equal or unequal |
| 15 | S&F 100 mm dia sand Cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall |
| 16 | All as per item No 15 as above but 75mm |
| 17 | M&L 100mm CI Bends (any radius), with ovel acess door diminishing pieces or tapers (larger bore measured) |
| 18 | S&F in repair bib taps, fancy type, chromium plated, cast copper aloy ISI marked with crutch or butter fly handle high pressure screwed down for iron pipe of 15mm bore complete all as specified and directed. |
| 19 | S&F in repairs 15mm bore angle valve chromium plated screwed downfancy typehigh pressure screwd both ends for iron pipe of 15mm bore complete all as specified and directed. |
| 20 | S&F in repair fancy type Pillar tap cast copper alloy chromium platedwith capstan heads screwed down high pressure or without lettered hot or cold with long screwed, shanked and fly nuts screwed for iron pipe 15mm dia complete all as specified and directed. |
| 21 | Taking up or down GI pipes 15mm bore and connection including cleaning for refixing or removal un-serviceabl pipe, S&F GI tube 15mm bore medium grade galvanised ISI marked with all fittings complete on walls complete all as specified and directed. |
| 22 | Taking up or down GI pipes 20mm bore and connection including cleaning for refixing or removal un-serviceabl pipe, S&F GI tube 20mm bore medium grade galvanised with all fittings and fixed to short length complete all as specified and directed. |
| 23 | S&F for Flushing jet spray/ health faucet for pedestal pattern W.C including flexible pipe and brass Chromium plated nuts, fixed in repairs complete. |
| 24 | Roughening the surfaces of old concrete floor by picking, sweeping clean and washing down with water to remove dust, etc with and including taking out existing roof treatments, brushing neat cement slurry with 3.0 Kg of cement per Sqm and providing 10mm thick rendering in cement mortar 1:4 on fair faces of concrete, finished even and fair mixed with and including water proofing compound to receive treatment on roof Providing and laying of water proofing treatment of roof APP (Atactic polyproplyllen) modified prefabricated five layer 3mm thick water proofing membrane, with non woven polyester mat reinforcement of 160gsm, weight of [email protected] Kg/Sqm over a solvent based bitumenprimer, @0.30 Ltr/Sqm by same manufacturer conforming to IS: 3384-1986. The membrane shall be laid using bitmun torch. The end lap should be 100mm and the side lap must be minimum 75mm. The membrane shall be first laid up to the parapet wall junction and then shall be overlaped with another memberane (flashing) with an overlap covering upto a distance of 300mm. In case parapet height is less than upto 500mm, membrane shall be terminated at the top of parapet. All rain water pipes opening shall be suitable sealed with APP membrane all as specified and directed by Engineer-in-charge. ( The rate uncludes for fillling of crackes in existing roof with cement putty using suitablebonding agent (Shalocrate-42) before laying cement plaster all as directed by Engr-in-Charge |
| 25 | M&L two coat of Aluminium paint over APP membrane surface surfaces exc 10 cm width or girth |
| 26 | Dismantaling of old brick tile as in roof traetment and Cleaning ofexisting treatment of any description completely & washing rubbing with water |
| 27 | M&L 40mm thick brick tiles laid on cementmortar 15mm thick in CM 1:6 and joints grouted flush in cement mortar (1:3) mixed with 5% ofcrude oil by weight of cement complete all as specified and directed. |
| 28 | All as per item No 25 but except brick tileslaid on cementmortar 15mm thick in CM 1:6 and joints grouted flush in cement mortar (1:3) mixed with 5% ofcrude oil by weight of cement complete all as specified and directed. |
| 29 | M&L PCC padding in roof slabs/chhajjas in PCC 1:2:4 type B0 using 12.5mm graded crushed stone aggregate with and incl integral waterproofingcompound @ 3% weight of cement and providingnecessary slope towards outside. |
| 30 | S&F, 110mm bore, PVC rainwater (SWR) drainage pipes single socketed, in any length with rubber ring joints as in repair, fixed to walls with clamps complete all as specified and directed. |
| 31 | S&F for 110mm bore pipes,PVC (SWR) bends any radius fitting fo PVC (SWR) pipes as in repair complete all as specified and directed. |
| 32 | Taking down eaves gutters and rainwater pipes (any size or pattern),CI pipe including all fittings, heads, shoes, bends, swan-necks, etc., including cleaning or refixing or removal to Store (measured overall as fixed along the centre line over fittings and accessories) |
| 33 | S&F for PVC waste pipe 32mm dia, 60 cm long for WHBwith cup, fixed in repairs complete. |
| 34 | S&F grating round 100 mm size of stain less steel as in repair, complete all as specified and directed. |
| 35 | Demolition of brick work stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 36 | M&L for brick work in cement mortar 1:4 of old size sub class ‘B\" bricks straight or curved on plan exceeding 6m mean radius complete all as specified and directed. |
| 37 | All as per item No. 36 above but except bricks complete all as specified and directed |
| 38 | M&L for brick work with sub class ‘B’ bricks straight or curved on plan to any radius in half brick thick wallsbuilt in cement mortar 1:4 complete all as specified and directed. |
| 39 | Demolition of cement concrete unreinforced of any description in any position not otherwise specifically provided for complete all as specified and directed |
| 40 | M&L PCC 1:5:10, type E-2, (using 40mm graded crushed stone aggregate) in foundation filling/sunken floor and mass concrete,all as specified. |
| 41 | M&L for15mm thick plaster in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surfaces even and smooth without using extra cement complete all as specified and directed.complete all as specified and directed |
| 42 | S&F Doctor fixit Pidifin 2k high performance 2 component flexible Acrylic polymer modify cement base water proofing coating in two coat 1mm thick dry film mixed in ratio 2:1 by weight or 1.5:1 by volume product of M/S Pidilite Industry Limited Makers of Fevicol adhesive brand over 10mm thick rendering in cement mortar 1:4 mixed with liquid water proofing admixture of approved brand complete all as specifed & directed. |
| 43 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition, complete all as specified and directed |
| 44 | Providing precast cement concrete (1:2:4) type B-1 using 20mm graded crushed stone aggregate as in cover slabs and similar articles including necessary moulds/formwork set in cement mortar (1:6) complete all as specifed and directed. |
| 45 | M&L for Mild steel TMT bars 10mm dia and over cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 46 | M&L for Mild steel TMT bars 6mm to 8mm dia cut to length bent to shape required including cranking, bending, binding with mild steel wire (annealed) not less than 0.9mm dia complete all as specified and directed. |
| 47 | S&F in repair vitreous china wash down water closet pan (Orissa patern) white with integral foot rest ofof size 580x440mm white with integral foot rest (excluding flushing cistern and flush pipe), including connection to trap, and to flushing pipe, anty syphonage pipe etc. and including \"P\" and \"S\" trap complete incl making good to floor complete all as specified and directed. |
| 48 | S&F in repair Vitreous China wash down water closet pan and trap, (pedestal pattern) including fixing bolts and connecting to drain pipe, including white seat cover plastic flat bottom and MS Chromium plated hinging device and connection to flush pipe, anti symphonic pipe etc complete all as specified and directed. |
| 49 | S&F in repair Vitreous china Urinal, Half stall type, white (excluding flushing cistern, flush pipe and waste pipe) complete incl providing andfixing plugs, beddding urinal against wall in cement mortar 1:2, securing urinal to plug with and including 60mm long brass screw, pointing around urinal back in cement; including waste pipe. |
| 50 | S&F in repair vitreous china wash hand basin white of bowl size 550x400mm including waste coupling and waste pipe PVC 32mm dia to be fixed over mild steel bracket including 15mm bore pillar tap brass chromium plated with capstan head screwed down high pressure with or without lettered Hot or Cold complete all as specified and directed. |
| 51 | S&F low level 10 ltrs capacity PVC valveless symphonic action type flusing cistern low level white with inlet ball valve float ovel handle including 32mm dia PVC flushing pipe complete all as specified and directed. |
| 52 | Dismantling ofwall tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises,M&L for providing glazed joint free ceramic colouredwall tiles of exterior quality of size 450mmx350mmx7mm thick, set, jointed in colour cement to match laid over and including 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed. |
| 53 | Dismantling of floor tiling incl cement mortar bedding (but not backing)removing serviceable tiles to a store and rubbish off permises,M&L Non skid joint free ceramic colour tiles 7 to 8 mm thick ( sq/ rect) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, infloor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour of tiles laid over and including 15mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 54 | M & L for hard corebroken stoneof gauge n.exc 63 mm deposited , spread and levelled in layers n.exc 15 cm thick, watered rammed to a true surface completeall as specified anddirected. |
| 55 | M&L for 20 - 25 mm thick coloured Cement concrete tile size 20 cm x 20 cm/ 25 cm x 25 cm/ 30 cm x 30 cmwith grey cement and pigment, Machine pressed, set and jointed and pointed in neat cement slurry in floors over 15 mm thick screed bed in CM 1:6 complete all as specified and directed . |
| 56 | M&L for Machine pressed precast coloured concrete interlocking paver block60 mm thick (Factory made rubber moulded) with grey cement and pigment any shape and size conforming to IS-15658-2006 of 60mm thickness, M-35 Grade fixed all as specified and directed . |
| 57 | M&L 75mm thick plain cement concret type C-2 1:3:6 (using 40mm graded crushed stone aggregate) as in flooring/Sub base/Plinth protectionall as spd and directed. |
| 58 | M&L Two coat of synthetic enamel paint over a coat red oxide primer on newsteel surfaces exc 10 cm width or girth |
| 59 | M&L for preparation of new plastered surface of wall and applying three coats of white washcomplete all as specified and directed. |
| 60 | Dismantling water tanks (Capacity of tank exc 250 Ltr but n exc 500 Ltr) and removing from site, S&FRotational moulded polyethelyne water storage tank three layered (cylindrical vertical with closed top hoisted fixed in position all as specified in SSR part-I, capacity of tank 500 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively 20mm GI pipe medium grade over flow pipe 15cm long and brass valve 20mm high pressure with polyethelyne float and fly nuts complete all as specified. |
| 61 | Dismantling water tanks (Capacity of tank exc 500 Ltr but n exc 1000 Ltr) and removing from site, S&FRotational moulded polyethelyne water storage tank three layered (cylindrical vertical with closed top hoisted fixed in position all as specified in SSR part-I, capacity of tank 1000 ltr incl inlet and outlet connection 20mm dia and 15mm dia GI pipes medium grade respectively 20mm GI pipe medium grade over flow pipe 15cm long and brass valve 20mm high pressure with polyethelyne float and fly nuts complete all as specified. |
| 62 | M&L 20mm Gun metal globe or gate walve with iron wheeled head, screwed both ends for iron and fixed in repairs |
| 63 | Disconnecting existing tanks, setting side for repairing cleaning and removing all scale and dirt etc. from tanks and from mouths circulating pipes and hoisting in same position of capacity upto and including 500 ltr and endorsed the word \"CLEANED ON WITH DATE with white paint including replacement of broken/unserviceable fitting such as Elbow Tee, socket, nipple of any size complete all as specified & directed |
| 64 | Disconnecting existing tanks, setting side for repairing cleaning and removing all scale and dirt etc. from tanks and from mouths circulating pipes and hoisting in same position of capacity exc 500 ltr but not exc 1000 ltr and endorsed the word \"CLEANED ON WITH DATE with white paint including replacement of broken/unserviceable fitting such as Elbow Tee, socket, nipple of any size complete all as specified & directed |
| 65 | Taking down cement plaster on brick or concrete surface and description including raking out joints Hacking for key scrubbing down with water, M&L Rendering 15mm thick in cement mortar 1:4 on fair faces of brick work or concrete surfaces finishing the surface even and smooth without using extra cement mixed with and including water proofing compound including two coats of cement base paint over a coat of primer on newly plastered surface of wall including preparation of surface and curing after applying each coat complete all as specified and directed.NOTE incl necessary scaffolding aggangment |
| 66 | S&F steel window/ventilator withtubular frame factory made double shutters of size 79mmx39mm,16 guage rectangular tubular frame with side hung shutter glazed and guaged with glazing bars 12x3mm flat iron incl projecting typehinges with steel handles and steel peg stay dovetailed or welded incl incluing necessary locking arrangment complete, incl two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed & shown onDrg No. CEPZ/TD-245/01 and 246/02 sheet 1/2 &2/2.(wire guage and glass shall be measured and paid seperately) |
| 67 | S&F Mild steel framed work such as grills, gratings using square/round bar with ends of bars shoulders/welded drilling holes for fixing of guard bars all as specified. |
| 68 | S&F Galvanised mild steel wire cloth 0.56mm of nominal dia of each wire and average width of aperture 1.18 mm and fixed with tinned tacksor galvanised wire staples. |
| 69 | M&L for Preparing the new steel surfaces of any description over 10cm width or girth and applying two coats of synthetic enamel paintall as specified. |
| 70 | Taking down chowkhat or frame with shutter (without taking off shutter from the frame) n exc. 1.50 Sqm each incl taking out hold fast. |
| 71 | S&F factory made solid PVC door frame of size 50mmx47mm made out of 5mm plain colour sheet reinforcement with MS square tube. All as specified . |
| 72 | S&F factory made solid PVC door shutter, 28 to 30mm thick (style) with 2,4 or 6 raised panel design with 2mm moulded prelam PVC sheet on on the front face and 2mm plain colour PVC sheet on back face with wood free EPS all aws specified. |
| 73 | S&F butt hinges 100mm, cold rolled medium weight mild steel all as specified. |
| 74 | S&F 125mm size, extruded aluminium alloy handles, fabricated type, anodised. |
| 75 | S&F 150mm long aluminium tower bolts (ISI Marked) extruded typeall as specified. |
| 76 | S&F in repair 20mm ball valve high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified. |
| 77 | S&F in repair 25mm ball valve high pressure with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed complete all as specified. |
| 78 | S&F Galvanised mild steel wire cloth 0.56mm of nominal dia of each wire and average width of aperture 1.18 mm and fixed with tinned tacksor galvanised wire staples. |
| 79 | S&F 3mm thick sheet glass ordinary quality and glazing with oil putty in square n exc. 0.50 Sqm in each pane all as specified. |
| 80 | S&F in repairs SS Tubular towel rail of chromium plated, 20mm dia, D type, 60cm long between flanges, fixed in repairs complete. |
| 81 | S&F in repairchromium plated shower rose 75mm size with or without swivel joints, including fixing to steel pipe or union complete all as specified and directed. |
| 82 | S&F in repair CPtoilet paper holder, superior quality complete all as specified and directed. |
| 83 | S&Fin repairs soap dish dish type of milld steel Chromium platedand wooden/plastic cleats , completeall as specified and as directed. |
| 84 | Dismantling of Asbestos cement (Corrugated, semicorrugated, etc) sheets in roof coverings, M&L pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws. Sheet colour approved by Engineer-in-Charge complete all as specified and directed. |
| 85 | S&F roof trusses (framed), trussed, purlins, rafters rails and fastenings and heavy bracket framing (beem, tee, angle, channel or flat sections) including distance pieces, cleats etc of FE 410 W (Gde E-250) quality B including one shop coat of red oxide primer, complete all as specified and directed. |
| 86 | M&L for PCC (1:3:6) type C-2 using 20mm graded crushed stone aggregate as surface channelsdrain and post holes etc including necessary form work complete all as specified and directed. |
| 87 | M&L for PCC 1:2:4 type B1 using 20mm graded stone aggt as in coping all as spd and directed. |
| 88 | M&L for Sand filling under floors or infoundations including watering andconsolidation |
| 89 | Excavation in post holes (or similar holes) each nexc 0.5 cu.m, getting outgetting out in soft/loose soil |
| 90 | M & L for Hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.and similar work conforming to Fe-290 Gde E-165 |
| 91 | S&F 12mm dia mild steel bolts (machine made) with hexagonal or square head one end and screwed the other or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nutn.exc 5 cm long |
| 92 | Supply only MS galvanised chain link fencing mesh any size, complete all as specified and directed. |
| 93 | Fixing only chain link fencing of any size including line wires, any mesh size and type to any type of standards, rails, straining bolts etc. including provision of binding wire. |
| 94 | M&L in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 95 | M&L for re-securing of angle iron post of any size including seprating old concreteand excavation for post holes for iron post |
| 96 | Note: In case the tenderer quotes different rates for similar item then lowest rate shall only be applicable for payment and contractor shall not have any claim on this account. |