Military Engineer Services-MES has published Repair/ Replacement Of Internal Wiring And Connected Services For Otm Accn, Air Conditioner, Refrigerator, Deeep Freezers And Repairs/ Replacement Of Mcb Db, Mcbs Meter Box, Submian Wiring, Bldg Earthing And Misc Works At 14 Gtc Subathu Under Ge Kasa . Submission Date for this Tender is 13-10-2022. Electrification Work Tenders in subathu Himachal Pradesh. Bidders can get complete Tender details and download the document.
Sr No | CorrigendumDate | Corrignedum | CorrigendumType | NewSubmissionDate |
1 | 27-Sep-2022 | CERTAIN AMENDMENTS TO TENDER DOCUMENTS DUE TO ADMINISTRATIVE REASONS | Other | 06-10-2022 |
2 | 06-Oct-2022 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 13-10-2022 |
Sl. No. | Item Description |
1 | Schedule "A" Section - I |
2 | Taking down old and unserviceable, Main Panel/Switchboardany type including fuses, MCBs etc after removing all connections and making good the disturbed surface all as directed by Engr-in-charge. |
3 | Taking down old and unserviceable, Distribution boardany type including fuses after removing all connections and making good the disturbed surface all as directed by Engr-in-charge. |
4 | Taking down old and unserviceable submain wiring/ service cable any size of two core including earth wire complete including batten/ conduit and make good the disturbed surface to match the existingsurface, all as directed by Engr-in-charge. |
5 | Supply, installation, testing & commissioning factory made CPRI approved powder coatedLT panel board cubical type, front openable wall mounted, indoor, weather and vermin proof, made out of 1.6mm thick MS Sheet and Section complete painted with two coats of synthetic enamel paint (spray painting) over a coat of primer. Panel shall be suitable for housing and including copper bus bar 04 Nos 200 Amps rating, MCCB 100 Amps FP 25 KA-01 No, MCBSPN 32 to 40 Amps -05 Nos, Digital voltmeter (0-500V) with selector switch -01 No, Digital ammeter (0-200 A) with CTs and selector switch -01 No, indicator lamp (set of three) -01 set. Panel shall be complete in all respects, including internal connections and control wiring with suitable size of copper wire, 05 Nos holes with rubber bushing on top of the panel for sub-main entry and 02 holes in bottom of the panel with cable glands for cable entry should be provided. Panel shall be fabricated in such a way that the MCCB and MCBs shall be operated in door closed position. All cable connections shall be done using suitable size lugs. The size and shape of panel shall be as directed and approved by Engr-In-Charge includingsupply and fixing temperproof electronic energy meter - 05 Nos. of 10-60 Amps 230 Volts, with electronic display single phase on wooden board of suitable size including making all inlet and outlet connection to the meter using suitable size copper conductor cable and lugs, with locking provision complete all as specified and directed. |
6 | Supply, installation, testing & commissioning factory made CPRI approved powder coatedLT panel board cubical type, front openable wall mounted, indoor, weather and vermin proof, made out of 1.6mm thick MS Sheet and Section complete painted with two coats of synthetic enamel paint (spray painting) over a coat of primer. Panel shall be suitable for housing and including copper bus bar 04 Nos 200 Amps rating, MCCB 100 Amps FP 25 KA-01 No, MCBSPN 32 to 40 Amps -07 Nos, Digital voltmeter (0-500V) with selector switch -01 No, Digital ammeter (0-200 A) with CTs and selector switch -01 No, indicator lamp (set of three) -01 set. Panel shall be complete in all respects, including internal connections and control wiring with suitable size of copper wire, 07 Nos holes with rubber bushing on top of the panel for sub-main entry and 02 holes in bottom of the panel with cable glands for cable entry should be provided. Panel shall be fabricated in such a way that the MCCB and MCBs shall be operated in door closed position. All cable connections shall be done using suitable size lugs. The size and shape of panel shall be as directed and approved by Engr-In-Charge includingsupply and fixing temperproof electronic energy meter - 06 Nos. of 10-60 Amps 230 Volts, with electronic display single phase on wooden board of suitable size including making all inlet and outlet connection to the meter using suitable size copper conductor cable and lugs, with locking provision complete all as specified and directed. |
7 | S & F for Sheet Metal enclosure double door for DBs when MCBs to be used SPN- 12 Way, with 240 V, 200 Amp rated busbar complete all as specified & directed by Engr-in-Charge. |
8 | Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level connected to GI wire 4 mm as earthing lead by means of nut, bolts and check nuts and washers, GI light grade protection pipe 15 mm dia upto 7.5 M, GI watering pipe 20 mm dia medium grade, RCC cover with funnel, excavation in any type of soil, PCC pit charcoal, salt all as shown in electrical plate No 5 of SSR Part I, including earth test point upto panel board, all as specified or indicated including testing on completion. |
9 | Supply, laying, jointing and testing of cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cable,heavy duty, 1100 Volts grade with stranded Aluminium conductor of size 25 Sqmm 4 core, complete, all as specified and directed. |
10 | Supply / laying and fixing 40mm bore galvanised steel tubes with all fittings, light grade, laid in trenches for cable protection complete all as specified and directed. |
11 | Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 M depth in soft/ loose soil and gating out in soft / loose soil complete all as specified and directed. |
12 | M&L for washed river dry sand cushioning in trenches 80mm thick before laying the cable and 150mm thick after laying the cable including spreading levelling andhard punning complete all as specified & directed by Engr-in-Charge. |
13 | Material and labour for contineous brick edging withwidth equal to the depth of the brick of whole sub class "B" bricks laid on edge complete all as specified and directed. |
14 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n. exc. 25cm thick in soft / loose soil complete all as specified and directed. |
15 | Removing surplus excavated materials n.exc. 50 Mtr and depositing where directed at a level n. exc. 1.5 Mtr above the starting point complete all as specified and directed. |
16 | Taking down carefully copper/AImn point wiring (Light,Fan/Point Socket or power) (fittings such as switches ceiling roeses, pendent, regulators, sockets etc to be measured & paid seprately) & making good to disturbed surface of walls/floors etc. |
17 | M&L point wiring using approved colour codingas per IS with stranded FRLS copper conductor single core 1.5 Sqmm (Nominal area), PVC insulatedcable in and incl casing-n-caping medium grade with all connecting accessories incl mild steel sunken boxes suitable formounting switch/sockets with earth dolly duly painted with two coats of anti corrosive paint over a coat of red oxide primer incl mounting frame over cover plate, covered with 3mm thick plastic laminated sheet, incl PVC insulated FRLS copper conductor 1.5 Sqmm (Nominal area) single core PVC cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified. Note : (i)Switch/sockets shall be measured and paid for separately.contaractor provided wiring diagram board. |
18 | One light pointcontrolled by one switch complete all as specified & directed by Engr-in-Charge. |
19 | One bell pointcontrolled by one switch complete all as specified & directed by Engr-in-Charge. |
20 | One switch socket outlet 3 pin,5 Amp on the independent board complete all as specified & directed by Engr-in-Charge. |
21 | One switch socket outlet 3 pin,5 Amp on same board complete all as specified & directed by Engr-in-Charge. |
22 | One light point controled by two way switches with cables 1.5 Sqmm size complete all as specified & directed by Engr-in-Charge. |
23 | All as per item No 16.00 here-in-before but with 1100 volts gradestranded FRLS copper conductor single core 2.5 Sqmm (Nominalarea )single core flame retardant low smoke (FRLS)PVC insulated and unseathedcable ISI-694 marked TEC and FIA approved in and includingPVCcasing-n-caping. ISI marked with all accessories PVC junction boxes mild steel sunken boxes (terminal boxes) made out of 1.5 mm thick MS steel suitable for switches/ sockets with earth dolly duly painted both internally and externally with two coats of anti corrosive paint over a coat of red oxide primer covered with and including 3 mm thickplastic laminated sheet including flame retardant low smoke (FRLS) PVC insulated unsheathed stranded copper condutor 2.5 sqmm (nominal Area), 1100 volts grade single core cable as earth continuity conductor to common earth and connected to earth dolly complete all as specified and directed. Note : (i)Switch/sockets shall be measured and paid for separately. |
24 | M&L point wiring using approved colour codingas per IS with strandedFRLS copper conductor single core 1.5 Sqmm (Nominal area), PVC insulatedcable in and incl PVC conduit (ISI marked) including cutting chiseling and grouting concealed PVC conduit pipe, tee, elbow and bend etc.andwith all connecting accessories incl mild steel sunken boxes suitable formounting switch/sockets with earth dolly duly painted with two coats of anti corrosive paint over a coat of red oxide primer incl mounting frame over cover plate, covered with 3mm thick plastic laminated sheet, incl PVC insulated FRLS copper conductor 1.5 Sqmm (Nominal area) single core PVC cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified. Note : Switch/sockets shall be measured and paid for separately :- |
25 | One light pointcontrolled by one switch complete all as specified & directed by Engr-in-Charge. |
26 | One switch socket outlet 3 pin,5 Amp on the independent board complete all as specified & directed by Engr-in-Charge. |
27 | One switch socket outlet 3 pin,5 Amp on same board complete all as specified & directed by Engr-in-Charge. |
28 | One light point controled by two way switches with cables 1.5 Sqmm size complete all as specified & directed by Engr-in-Charge. |
29 | One bell/buzzer point controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm size complete all as specified & directed by Engr-in-Charge. |
30 | All as per item No 18.00 here-in-before butwith 2 single core PVC insulated FRLS and sheathed copper conductor of size 2.5 Sqmm in and including PVC conduit (ISI marked) including cutting chiseling and grouting concealed PVC conduit pipe, tee, elbow and bend etc.andwith all connecting accessories with 2.5 Sqmm PVC insulated FRLS copper conductor as earth wire and connecting to common earth dolly for 6 pin 16 Amp socket outlet on the independent board.using 2.5 sqmm copper cable. |
31 | S&F Lamp holder,PVCinsulated body, with back plate suitablefor batten fitting complete all as specified & directed by Engr-in-Charge. |
32 | M& L switch piano,flush type, single pole 1 way 6 Amp,ISI marked complete all as specified & directed by Engr-in-Charge. |
33 | S&F switch pianoflush type, single pole 1 way 16 Amp complete all as specified & directed by Engr-in-Charge. |
34 | M& L socket 5 pin 6 Amp piano flush type,ISI marke complete all as specified & directed by Engr-in-Charge. |
35 | S&F socket out let 2 in one 6 pin 6 & 16 Amp complete all as specified & directed by Engr-in-Charge. |
36 | S & F bell,AC 240 volts,single pole,multi musical type Office use complete all as specified & directed by Engr-in-Charge. |
37 | S&F bell push, 6 Amps, SP, flush type complete all as specified & directed by Engr-in-Charge. |
38 | S&F ceiling rose, 3 phase/ PVC/ polycorbonate,isolate bady complete all as specified & directed by Engr-in-Charge. |
39 | M& L switch piano,flush type, single pole 2 way 6 Amp,ISI marked complete all as specified & directed by Engr-in-Charge. |
40 | Supply and fixing in replacement inl LED bulbtype engagement ligts for VVIP9/10 watt type of 3 light red,yellow,greenlamp withholder andcomplete all as specified and directed. |
41 | S & F in replacementLED bulb 10 watt complete all as specified & directed by Engr-in-Charge. |
42 | Supply and fixing in replacement Decorative box type fitting Pre-wired for and incl LED tube 18/20 watt 6000K 4 ft IP20 linear LED T8 tubular lamp with extruded aluminium/PC body and PC diffuser complete with inbuilt driver complete all as specified and directed. |
43 | Supply and fixing in replacement wall Mounting LEDfitting 9/10 watt 6000K 2 ftBasic all purpose surface and wall mounted led batten with polycarbonate housing & integrated electronic drivercomplete all as specified and directed. |
44 | S&Fin replacement Decorative wall light ?xture made up of Polycarbonate , fancy type, made outof Polycorbaonate,suitable for B-22 base holderfixed as in repair complete all as specified and directed. |
45 | S&F sleek LED mirror light with diffuser 10 W wattalong with all accessoriesprewired including connecting with copper flexible cable of size 0.7 Sqmm 3 core and all as specified and directed. |
46 | S & Fin replacement Bulkhead luminaire Decorative Energy saving new generation 10W LED IP65 with opal diffuser incl electronics driver & connection with copper flexible cable 3 core complete all as specified and directed. |
47 | Supply in replacementaluminium extruded energy efficient09W inverter batten with inbuilt Li ion battery for power backup of 2 to 3 hrs with SS & MsMS zinc plated and passivated hardwares, IP20 ingress protection, LM80 certified LED complete all as specified & directed by Engr-in-Charge. |
48 | Supply in replacementaluminium extruded energy efficient12W inverter batten with inbuilt Li ion battery for power backup of 2 to 3 hrs with SS & MsMS zinc plated and passivated hardwares, IP20 ingress protection, LM80 certified LED complete all as specified & directed by Engr-in-Charge. |
49 | Supply in replacement aluminium extruded energy efficient22W inverter batten with inbuilt Li ion battery for power backup of 2 to 3 hrs with SS & MsMS zinc plated and passivated hardwares, IP20 ingress protection, LM80 certified LED complete all as specified & directed by Engr-in-Charge. |
50 | Supply and fix in replacement LED luminaire 600mmx600mm recessed LED 34/36 wattEnvironmental friendly,roof ceiliang LED light new generation,aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source, suitable for Armstrong/Grid ceiling, IP 20 , with electronics driver including connection with copper conductor 3 core of 0.7 sqmm and all as specified and directed. . |
51 | Single pole and Neutral Sheet metal enclosure with a 2 pin and earth plug and socket complete with one single pole MCB 20 Amps complete all as specified & directed by Engr-in-Charge. |
52 | S &F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, TPN 4 way, 415 Voltcomplete all as specified & directed by Engr-in-Charge. |
53 | S &F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 6 way, 240 Volt (power db) complete all as specified & directed by Engr-in-Charge. |
54 | S &F sheet metal enclosure with double door for DBs conforms to IS:8623.III , IP:43 protection, shrouded neutral bar and cement spill protector, 8 way, 240 Volt (light DB). |
55 | S & FMCB, "B" curveSPN, 240 V, 32-40Amp240 volt breaking capacity 10 Ka complete all as specified & directed by Engr-in-Charge. |
56 | S & FMCB,"B" curve TPN, 415 V, 40Ampbreaking capacity 10 kA complete all as specified & directed by Engr-in-Charge. |
57 | S & F MCB "B" curve single pole 6 to 32 Amp, 240 volt breaking capacity 10 kAcomplete all as specified & directed by Engr-in-Charge. |
58 | M&L for submain wiring with 2 single corePVC insulated FRLS cable 6 Sqmm copper conductor PVC sheathed in and including rigid PVC conduit heavy duty of suitable size incl cutting chiseling of wall and making good to disturbed surface of walls / floor etc with plastering painting etc so as to match with the existing finishes, drawn with 6 Sqmm PVC insulated copper conductor cable for earth wire fixed with shaddle and connectingto common earth teriminals complete all as specified. Note: For payment purpose 3 runs of 6 sqmm cable will be measured as one run” |
59 | M&L for submain wiring with 2 single corePVC insulated FRLS cable 6 Sqmm copper conductor PVC sheathed in and including rigid PVC casing -n-caping, drawn with 6 Sqmm PVC insulated copper conductor cable for earth wire fixed with shaddle and connectingto common earth teriminals complete all as specified. Note: For payment purpose 3 runs of 6 sqmm cable will be measured as one run” |
60 | M&L for submain wiring with 2 single corePVC insulated FRLS cable 4 Sqmm copper conductor PVC sheathed in and including rigid PVC casing -n-caping, drawn with 4 Sqmm PVC insulated copper conductor cable for earth wire fixed with shaddle and connectingto common earth teriminals complete all as specified. Note: For payment purpose 3 runs of 4 sqmm cable will be measured as one run” |
61 | Supply and fix in replacement of sheet metal enclosure, with 100 Amps Triple pole and neutral MCCB415 volts, 04 way, with 200 Amps rated copper bus bar and IP - 43 & IK 09 protection including provision of three Nos 63 Amp 4 pole isolatorwith metal double door and flush to wall including all cutting etc on wall and making good including two coats of white / colour washing / distempering etc to match the existing disturbed surfaces complete all as specified and as directed. |
62 | Supply and fixin replacement2 pin CFL (pin type) 11 watt ,lumen type 2P 6500K / 2700K ISI marked all as specified and directed by Engr in charge. |
63 | Supply and fixin replacementof PVC Casing and capping of size 25mm ISI marked all as specified and directed by Engr in charge. |
64 | Supply and fixin replacementaluminium extruded energy efficient30W inverter RTC building security light with inbuilt RTC for auto ON/OFF & must have diming facility from 10 to 100 %, IP66 ingress protection having inbuilt Li-ion battery of 5200mAH LED . |
65 | Supply and fix in replacement to existing 1x18 Watt CFL post top light fitting withDecorative LED Post Top Lantern with transparent difuser of cap 30 Watt complete all as specified and directed by Engr-in-Charge. |
66 | Taking out old unserviceable compressor of window type air conditioner 1.5 Ton capacity ofany make and providing of newcompany sealed compressorunit of same size and make, connecting up suction and discharge pipe with gas welding, pressure testing, leakage rectification vaccumising and charging of Refrigerant gas R-12/R22/non CFC,compressor oil, testing commissioning complete. Note :- Compressor shall be got replaced from manufacturer orits authorized dealer.Necessary guarantee certificate shall be produced |
67 | All as per item No 55.00 but replacement with new company sealed compressor unit forsplit type AC of 1.5/2 ton capacity complete. Note :- Compressor shall be got replaced from manufacturer orits authorized dealer.Necessary guarantee certificate shall be produced |
68 | Replacement of running capacitor 36 mfd complete all as specified & directed by Engr-in-Charge. |
69 | Replacement of running/ starting capacitor 100-120 mfd complete all as specified & directed by Engr-in-Charge. |
70 | Replacement of starting relay for 1.5/2 ton capacity AC complete all as specified & directed by Engr-in-Charge. |
71 | Replacement of thermostat switch for any capacity window/split type air conditioner complete all as specified & directed by Engr-in-Charge. |
72 | Replacement of over load protector for any type AC 1.5/2 Ton capacity complete all as specified & directed by Engr-in-Charge. |
73 | Replacement of PVC air filter suitable for 1.5/2 ton window type air conditioner of any make complete all as specified & directed by Engr-in-Charge. |
74 | Replacement of blower aluminium/PVC suitable for 1.5/2 ton window type air conditioner of any make complete all as specified & directed by Engr-in-Charge. |
75 | Replacement of condenser fansuitable for 1.5/2 ton window type air conditioner of any make complete all as specified & directed by Engr-in-Charge. |
76 | Replacement of condenser fan motor 1/5 HP 230 volt AC single phase double shaft suitable for 1.5 ton window type AC complete all as specified & directed by Engr-in-Charge. |
77 | Replacement of condenser fan motor single phase 230 volt AC suitable for 1.5/2 Ton split type AC capacity of existing make complete all as specified & directed by Engr-in-Charge. |
78 | Replacement of decorative front grill suitable for window type air conditioner capacity 1.5 Ton as per existing complete all as specified & directed by Engr-in-Charge. |
79 | Replacement of sheet metal enclosure with two pin and earth pin plug and socket complete,with one SP,MCB "C"curve 20 Amps 240 volts grade complete all as specified & directed by Engr-in-Charge. |
80 | Replacement of copper cooling coil assembly suitable for 1.5/2 Ton window type air conditioner of any make complete all as specified & directed by Engr-in-Charge. Note:-Charging of refrigerant gas shall be measured and paid separately. |
81 | Replacement of condenser assembly suitable for 1.5 Ton window type air conditionercomplete all as specified & directed by Engr-in-Charge. Note:-Charging of refrigerant gas shall be measured and paid separately. |
82 | Taking down window/split type air conditioner of any capacity / make / size at site,opening top and side covers disconnecting all electrical controls components and cleaning the complete units with electric blower and sprayingclean water, descaling withcoil shine solution in both side of cooling coil and condenser, brush cleaning with nylon brush and washing with clean water, refixing the covers and making electrical connection of all the controls and components, installing back the same on site testing, commissioning incl with black carresive resistant paint coat to bottom complete all as specified & directed by Engr-in-Charge. |
83 | Replacement of electric wiring kit suitable for 1.5 Ton window type AC of any make complete all as specified & directed by Engr-in-Charge. |
84 | M&L Gas rechargingin window/split type AC 1.5 Ton/2 Ton capacity of any make including pressure testing, leakage rectification, vaccumising and testing commissioning complete all as specified & directed by Engr-in-Charge. |
85 | Replacement of revolving motor kit for louvers (for AC grill) in window type AC 1.5 Ton of any make and model complete all as specified & directed by Engr-in-Charge. |
86 | Replacement of PCB board suitable for 1.5/2 Ton AC of existing make complete all as specified & directed by Engr-in-Charge. |
87 | Replacement of copper pipe 6/7 mm size with thermo insulation suitable for 1.5/2 Ton AC ofexisting make complete all as specified & directed by Engr-in-Charge. |
88 | Replacement of copper pipe 14/15 mm size with thermo insulation suitable for 1.5/2 Ton AC ofexisting make complete all as specified & directed by Engr-in-Charge. |
89 | S & F in repairs framed brackets of angle or tees with web and flanges cut to shape drilled and counter sunk or screw including bending and welding angle as necessary riveting etc not exc 10 Kg each bracket confirming to Fe 290 Gde E-165 complete all as specified & directed by Engr-in-Charge. |
90 | Taking downold unserviceable compressor of water cooler of capacity 40/80 litres any make/size and providing new company sealed compressor and connecting up suction and discharge copper pipe with gas welding, pressure testing of leakage, leakage rectification, vacumising and charging of refrigerant gas R-22/non CFC , testing, commissioning complete all as specified & directed by Engr-in-Charge. |
91 | All as per item No 79.00 but water cooler of capacity 150 litres complete all as specified & directed by Engr-in-Charge. Note for Srl item 79.00 to 80.00:-Compressor shall be purchased from authorised dealer of concerned manufacturer or company and necessary guaranty certificate shall be produced. |
92 | Replacement of starting capacitor 80-100 mfd complete all as specified & directed by Engr-in-Charge. |
93 | All as per item No 81.00 but 40-60 MFD complete all as specified & directed by Engr-in-Charge. |
94 | All as per item No 81.00 but 60-80 MFD complete all as specified & directed by Engr-in-Charge. |
95 | Replacement of thermostat switch for water cooler any cap complete all as specified & directed by Engr-in-Charge. |
96 | Replacement of condenser fan motor 1/35 HP 250 Volts AC Single phase suitable for water cooler complete all as specified & directed by Engr-in-Charge. |
97 | Replacement of starting relay kit suitable for any make & capacity water cooler complete all as specified & directed by Engr-in-Charge. |
98 | Replacement of condenser fan blade for 1/35 HP fan motor suitable for water cooler of any make/ capacity complete all as specified & directed by Engr-in-Charge. |
99 | All as per item No 87.00 but for 1/10 HP fan motor complete all as specified & directed by Engr-in-Charge. |
100 | Replacement of push cock chromium plated 15 mm dia suitable for existing water cooler complete all as specified & directed by Engr-in-Charge. |
101 | M& L gas charging R-22/non CFCin water cooler of any capacity and make including pressure testing, leakage rectification, vaccumising and testing commissioning complete all as specified & directed by Engr-in-Charge. |
102 | Replacement of electric wiring kit suitable for water cooler of any make and capacity complete all as specified & directed by Engr-in-Charge. |
103 | Replacement of running capacitor 30 mfd complete all as specified & directed by Engr-in-Charge. |
104 | All as per item No 92.00 but 25 mfd complete all as specified & directed by Engr-in-Charge. |
105 | All as per item No 92.00 but 10 mfd complete all as specified & directed by Engr-in-Charge. |
106 | Replacement of float valve assembly suitable for water cooler of any size/capacity non metallicPTMT synthetic body complete all as specified & directed by Engr-in-Charge. |
107 | Replacement of receptacle tray as per existingsuitable for water cooler complete all as specified & directed by Engr-in-Charge. |
108 | Replacement of PVC cable three core copper coductor multistranded 40/0.0076, 1100 V grade complete all as specified & directed by Engr-in-Charge. |
109 | S&F in replacement Plug top 16A, 3 pin, 230 AC, ISI markedcomplete all as specified & directed by Engr-in-Charge. |
110 | PVC waste pipe 32mm, dia with complete fittings suitable for water cooler of any make and capacity complete all as specified & directed by Engr-in-Charge. |
111 | M&L for Spray painting of outer surface of water cooler of any make ofcapacity 40/80 ltrs with two coats of synthetic enamelpaint of approved colourafter preparation of surface including filling of depressions over existing surface complete all as specified & directed by Engr-in-Charge. |
112 | All as per item No 100.00 but of capacity 60/120 and 150 litrescapacity complete all as specified & directed by Engr-in-Charge. |
113 | Taking down old sealed unit of refrigerator 165-185 ltrs capacity of any make and providingnew company sealed compressor ofsame size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and charging of refrigerant gas R-12/ non CFCtesting commissioning complete all as specified & directed by Engr-in-Charge. |
114 | All as per item No 102.00 but 190 to 220 ltrs capacity complete all as specified & directed by Engr-in-Charge. |
115 | All as per item No 102.00 but 230 to 310 ltrs capacity complete all as specified & directed by Engr-in-Charge. Note for Srl item 102.00 to 104.00:-Compressor shall be purchased from authorised dealer of concerned manufacturer or company and necessary guaranty certificate shall be produced. |
116 | Replacement of over load relay suitable for low/high speed refrigerator compressor of any capacity complete all as specified & directed by Engr-in-Charge. |
117 | Replacement of refrigerator drier made out of copper tube suitable for any capacity refrigerator complete all as specified & directed by Engr-in-Charge. |
118 | Replacement ofthermostat suitable for any capacity refrigerator complete all as specified & directed by Engr-in-Charge. |
119 | Replacement of Magnetic door gasket suitable for 165 to 220ltrs capacity refrigerator of any make complete all as specified & directed by Engr-in-Charge. |
120 | All as per item No 108.00 but for 230/286/300/310 ltrs capacity refrigerators complete all as specified & directed by Engr-in-Charge. |
121 | Replacement of door handles of refrigerator of any make and capacity complete all as specified & directed by Engr-in-Charge. |
122 | Replacement of freezer with cooling coil for 165 to 220 ltrs capacity refrigerator of existing make complete all as specified & directed by Engr-in-Charge. |
123 | All as per item No 111.00 but for 230/286/300/310 liters capacity refrigerators complete all as specified & directed by Engr-in-Charge. |
124 | Replacement of freezer door suitable for 165 to 220 ltrs capacity refrigeratorsof any make complete all as specified & directed by Engr-in-Charge. |
125 | All as per item No 113.00 but for 230/286/300/310 liters capacity refrigerators complete all as specified & directed by Engr-in-Charge. |
126 | Replacement of chill tray suitable for refrigerator of any make and capacity complete all as specified & directed by Engr-in-Charge. |
127 | Replacement of ice tray suitable for refrigerator of any make and capacitycomplete all as specified & directed by Engr-in-Charge. |
128 | Replacement oflamp 15 watt screw / Pin type suitable for any make and capacity refrigerator complete all as specified & directed by Engr-in-Charge. |
129 | M&L charging with refrigerantgas R-12/non CFCafter vacuuming /pressure testing and leakage testing including flushing the system in the refrigerator of any make of165 to 220 ltrs capacity complete all as specified & directed by Engr-in-Charge. |
130 | All as per item No 118.00 above but of 230/286/300/310 liters capacity complete all as specified & directed by Engr-in-Charge. |
131 | Replacement of vegetable tray suitable for refrigerator of 165 to 220 ltrs capacity of any make complete all as specified & directed by Engr-in-Charge. |
132 | All as per item No 120.00 but for 230 to 310 liters capacity complete all as specified & directed by Engr-in-Charge. |
133 | Replacement of plug top 5 Amps 3 pin, ISI marked complete all as specified & directed by Engr-in-Charge. |
134 | Replacement ofPVC cable copper conductor multistrandardflexible 3 core size 23 /0.0076 complete all as specified & directed by Engr-in-Charge. |
135 | Replacement of PCB board suitable for 165 ltrs to 220 ltrsrefrigeretors of existing make complete all as specified & directed by Engr-in-Charge. |
136 | Replacement of PCB board suitable for 230 ltrs to 310 ltrsrefrigeretors of existing make complete all as specified & directed by Engr-in-Charge. |
137 | Taking down sealed unit of deep freezer upto 320 ltrs capacity of any make and providing in replacement new company sealed compressorof same size, make and capacity connecting up suction and discharge pipe with gas welding, pressure testing, flushing the complete system, leakage rectification vaccumising and charging of refrigerant gas R-12/non CFCtesting commissioning complete all as specified & directed by Engr-in-Charge. |
138 | All as per Ser item No 126.00 here-in-before but 500 ltrs capacity deep freezer complete all as specified & directed by Engr-in-Charge. Note for Srl item 126.00 to 127.00 : -Compressor shall be purchased from authorised dealer of concerned manufacturer or company and necessary guaranty certificate shall be produced. |
139 | M& L gas chargingin deep Freezer upto 500 ltrs capacity with R-12/non CFC as applicablemake including pressure testing, leakage rectification, vaccumising and testing commissioning complete all as specified & directed by Engr-in-Charge. |
140 | Replacement of over load relay suitable for deep freezer upto 320 Ltrs capacity complete all as specified & directed by Engr-in-Charge. |
141 | Replacement of thermostat suitable for deep freezer upto 320 Ltrscapacity complete all as specified & directed by Engr-in-Charge. |
142 | Replacement of fan motorsuitable for deep freezer of any capacity complete all as specified & directed by Engr-in-Charge. |
143 | Opening the cover of automatic voltage stabilizer of any make and capacity, checking carefully, cleaning, servicing including tighteningof loose connection/ joints of all the controls/components to make the voltage stabilizer in serviceable condition complete all as specified & directed by Engr-in-Charge. Note :- Any component/control if replaced shall be measured & paid separately. |
144 | Supply and fix in Replacementvoltage stablizer2 KVAcomplete all as specified & directed by Engr-in-Charge. |
145 | Amount of credit of Rs. 63218.00 for retrived old material as mentioned in Schedule "A" section-II of tender document in pdf form, will be deducted offline while acceptence of tender. |
Copyright © 2024 · All Rights Reserved. Terms of Usage | Privacy Policy