Repair And Maint Of Summer / Winter Appliances And Petty Repair Of E / M Nature Including Internal Electrification At Dad New Cantt Allahabad, allahabad-Uttar Pradesh

Military Engineer Services-MES has published Repair And Maint Of Summer / Winter Appliances And Petty Repair Of E / M Nature Including Internal Electrification At Dad New Cantt Allahabad. Submission Date for this Tender is 15-10-2022. Electrification Work Tenders in allahabad Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

33989866
Corrigendum : Repair And Maint Of Summer / Winter Appliances And Petty Repair Of E / M Nature Including Internal Electrification At Dad New Cantt Allahabad
Open Tender
Indian
Uttar Pradesh
allahabad
15-10-2022

Tender Details

Repair And Maint Of Summer / Winter Appliances And Petty Repair Of E / M Nature Including Internal Electrification At Dad New Cantt Allahabad

Corrigendum Details

Sr No CorrigendumDate Corrignedum CorrigendumType NewSubmissionDate
1 22-Sep-2022 Ammendment of Other Other 08-10-2022
2 08-Oct-2022 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 15-10-2022

Key Value

Document Fees
INR 500 /-
EMD
INR 89980.0 /-
Tender Value
Refer document

BOQ Items

Name of Work:REPAIR & MAINT OF SUMMER/WINTER APPLIANCES AND PETTY REPAIR OF E/M NATURE INCLUDING INTERNAL ELECTRIFICATION AT DAD NEW CANTT ALLAHABAD
Sl. No. Item Description
1Taking down carefully point wiring of any type complete for light, fan socket or power point with fittings & fixtures such as ceiling rose, electric fittings, holders, switches, sockets, regulators, wooden batten, surface conduit/casing caping/conceal etc. including accessories including making good disturbed surface to match the existingcompleteall as specified & directed.
2M&L for point wiringwith FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) along with same size and type of wire as continuous earth wire connected to common earth dolly drawn in and includingnon metallicPVC casing and capingnot less than 20mm widemed grade ISI marked complete with all fixing accessories including factory madepressed steel concealed terminal boxof required size of 1.2mm thickduly painted with 3mm thick plasticlaminated sheet top cover with brass screw and cup washerscomplete all as specified and directedfor the following :- .
3(a) One light/fan/bell point controlled by one switch complete all as specified and directed
4(b) One point for socket outlet 5 amps on independent board the switch board complete all as specified and directed
5(c) One point for socket outlet 5 amp same board complete all as specified and directed
6(d) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board complete all as specified and directed
7M&L for point wiringwith FRLS PVC insulated unsheathed stranded copper conductor cable 1.5 sqmm (nominal area) 1100 volts grade, along with one single run of same size and type of copper wire as continuous earth wire to common earth dolly drawn in and including non metallic PVC rigid, medium grade surface conduit with all fixing accessories of 20mm dia, using new MS sunk terminal boxes of thickness not less 1.2mm, new 3mm thick laminated sheet cover with brass screw and cup washers with all acessories and making good to disturbed surfaces complete all as specified and directed for the following :-
8(a) One light/fan/bell point controlled by one switch complete all as specified and directed
9(b) One point for socket outlet 5 amps on independent board the switch board complete all as specified and directed
10(c) One point for socket outlet 5 amp same board complete all as specified and directed
11(d) One 3 pin 15 Amp socket outlet point controlled by one switch using 2.5 sqmm copper conductor cable with continuous earth wire of 2.5 sqmm copper conductor on independent board complete all as specified and directed
12M&L in repair switch piano flush button type, single pole, one way, 6 Amps complete all as specified and directed.
13S&F socket out let 2-in-1, 3 pin, 5 amp flush type completeall as specified & directed.
14S&F bell push piano flush type 5 amp, SP , 230V ACcompleteall as specified & directed.
15S&F call bell, ding dong type, AC, 230 V, single polecompleteall as specified & directed.
16S&F fan regulator, 5 stepped, electronic type, single phase, 80 watt, socket size incl connection completecompleteall as specified & directed.
17Supply & fixing in repair ceiling rose surface type bakelite 65x50mm three terminal complete all as specified and directed.
18Supply & fixing in repair pendant type lamp holder, PVC/Polycarbonate type with cord grip cap complete all as specified and directed.
19Supply & fixing in repair angle/batten type lamp holder, PVC/Polycarbonate type with back plate
20S&F socket out let 2-in-1, 3 pin, 5 & 15 amp flush type completeall as specified & directed.
21S&F switch piano flush type 16 amps, 230V AC single pole one waycompleteall as specified & directed.
22Supply & fixing in repair switch socket combination multipurpose 2 in 1, 6 pin, 5 and 15 Amp, and flush type universal complete all as specified and directed.
23S&F PVC insulation tape of width - 18 mm, thickness - 0.125 mm in length of 25 mtr, ISI markedfor proper insulation of joints in wire where as required or directed
24S&F in repair switch modular flush type 10 amps, single pole, one way 230 voltcompleteall as specified & directed.
25S&F in repair socket modular flush type suitable for 10 amp, 5 pin ,230 voltcompleteall as specified & directed.
26S&F in repair switch modular flush type 20 amps, single pole, one way ,230 voltcompleteall as specified & directed.
27S&F in repair socket modular flush type suitable for 20 amp, 6 pin ,230 voltcompleteall as specified & directed.
28S&F in repair fan regulator, modular type, 5 stepped, electronic type, single phase 230 volt includingconnection complete all as specified & directed.
29S&F in repair bell push modular flush type 6 amp 230 voltcompleteall as specified & directed.
30Supply & fixing in repair MODULAR white cover plate with frame suitable for following module type complete all as specified and directed.
31(a) 2 module
32(b) 3 module
33(c ) 6 module
34(d) 8 module
35S&F MCB single pole, 6 to 32 amps rating, 240 volts, "C" series, 10 KA breaking capacity & makingconnection complete all as specified and directed.
36S&FMCB single pole & neutral 40/63 amp, 240 volts, "C" series, 10 KA breaking capacity & makingconnection complete all as specified and directed.
37S&F in repair MCB tripple pole & neutral 63 amp, 415 volts, "C" series, 10 KA breaking capacity & makingconnection complete all as specified and directed.
38S&F in repair of MCCB 63 Apole series "C" Breaking capacity 25 KA415 Volts complete all as with separate at both side complete all as specified and directed.
39Taking down main switches fuse unit, MCB/Kit kat distribution board with steel enclosure along with MCB’s /Kit kat fuse of any amps/ways including wooden board or from steel board and making good disturbed surfacescompleteall as specified & directed.
40S&F sheet metal enclosure for MCB"s 240 volt 4 way single pole and neutral with 200 amps rated busbardouble door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wallcomplete all as specified and directed.
41S&F sheet metal enclosure for MCB"s 240 volt 6 way single pole and neutral with 200 amps rated bus bar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wall complete all as specified and directed.
42S&F sheet metal enclosure for MCB"s 240 volt 8 way single pole and neutral with 200 amps rated busbar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wallcomplete all as specified and directed.
43S&F sheet metal enclosure for MCB"s 240 volt 12 way single pole and neutral with 200 amps rated busbar, double door on wall with and including suitable flat iron clamps duly grouted/ fixed flush in the wallcomplete all as specified and directed.
44Supply & fixing in repair sheet steel enclosure in single pole and neutral fitted withtwo pin and earth plug and socket of current rating 20 amps complete with fixing one single pole MCB , "C" series of current rating 25 amp complete all as specified and directed. Make - Havells/Indo asian/HPL/L&T/Standard or as approved
45S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 0.75 Sqmm or 24/0.20, 1100 Volt grade, ISI marked complete all as specified and directed.
46S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 1.5 Sqmm or 22/0.30 or 48/0.20 or 30/0.25, 1100 Volt grade, ISI marked complete all as specified and directed.
47Supply & fixing in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size2.5 Sqmm or 36/0.30 or 80/0.20 or 50/0.25 , 1100 Volt grade, ISI marked complete all as specified and directed.
48Supply & fixing in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 4.0 Sqmm or 56/0.30 or 128/0.20, 1100 Volt grade, ISI marked complete all as specified and directed.
49S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 6.0 Sqmm or 84/0.30, 1100 Volt grade, ISI marked complete all as specified and directed.
50S&F in repair FRLS PVC insulated, unsheathed flexible copper conductor wire ofnominal size 10.0 Sqmm or 140/0.30, 1100 Volt grade, ISI marked complete all as specified and directed.
51Supply & fixing in repair PVC insulated, unsheathed flexible twin twisted copper conductor wire ofnominal size 23/0.0076 complete all as specified and directed.
52Supply & fixing in repair PVC insulated, unsheathed flexible twin twisted copper conductor wire ofnominal size 40/0.0076 complete all as specified and directed.
53Supply & fixing in repair condenser of 2.5 MFD, 440 Volt AC , conforming to IS - 1709 suitable for fans complete all as specified and directed.
54Taking down carefully sub main wiring of any nos of wire and size with earth wire on wooden batten/surface conduit/casing caping complete with its all accessories completeall as specified & directed.
55M&L for two single core (submain) FRLS PVC insulated cable with 2.5 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 2.5 sqmm stranded copper conductor earth continuity cable drawn in and includingnon metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed.Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
56M&L for two single core (submain) FRLS PVC insulated cable with 4 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 4.0 sqmm stranded copper conductor earth continuity cable drawn in and includingnon metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed.Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
57M&L for two single core (submain) FRLS PVC insulated cable with 6 sqmm nominal cross sectional area stranded copper conductor and one single core green PVC insulated 6 sqmm stranded copper conductor earth continuity cable drawn in and includingnon metallic, medium duty, rigid PVC conduit not less than 20 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed.Note :(I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate.(II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
58M&L for two single core (submain) FRLS PVC insulated cable with 10 sqmm nominal cross sectional area stranded copper conductor and one single core green FRLS PVC insulated 10 sqmm stranded copper conductor earth continuity cable drawn in and includingnon metallic, medium duty, rigid PVC conduit not less than 25 mm dia concealed in wall including all conduit and fixing accessories including cutting chases & making good to disturbed surfaces with cement mortar ratio of 1:4 and colour wash complete all as directed.Note :- (I) The cost for cutting, chases required shall deemed to be included in the quoted unit rate. (II) Two run of submain wire, one run of earth wire and one run of PVC conduit shall be measured one RM
59Supply & fixing surface /wall mounted light fitting in CRCA powder coated white housing with pre wired suitable for single T8 LED tube along with supply and fixing one number LED tube in polycarbonate housing of nominal wattage - 18 Watt, Lumen out put - 2100 Lm, Colour Temp - 6500 Kelvin, Size & Length - G13/ T8/ 4 Feet with integral/in built driver, having short circuit and surge protection including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed.Make Havells/Syska/Anchor/Wipro or as approved.
60Supply & fixing energy efficient LED light of 10 Watt of length - 02 Feet long having minimum 1150 Lumen output, wide voltage protection range 140-270 Volt AC housed in extruded aluminum housing (enhances safety) with high quality polycarbonate diffuser including making connection with two core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make Havells/Syska/Anchor/Wipro or as approved.
61S&F LED light fitting 10 Watt bulkhead luminaires in high pressure die cast aluminium housing,lumen out put - 700 Lm, colour Temp - 6500 K having Ingress protection - IP 65 fpr dust, water & IK 08 for external impact including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make Havells/Syska/Anchor/Wipro or as approved.
62S&F in replacement of worn out/old linear fluorescent tube of 36 watt with energy efficient/saving retrofitLED tube road in polycarbonate housing of nominal wattage - 18/20 Watt, Lumen out put - 2100 Lm or above, Colour Temp - 6500 Kelvin, Size & Length -T8/4 Feet, Operating Voltage - 230 Volt AC, THD = 20 % with intergral/in built driver, having short circuit and surge protection upto 4 KV and other safety test as per IS 15885 Part 2/Sec 13 including making minor addition/alteration in existing circuit as required complete all as specified and directed. Make Havells/Syska/Anchor/Wipro or as approved.
63S&F in replacement of existing worn out ceiling light with enviromental friendly, new generation, aesthetically designed, ultra modern recessed mounted LED light luminaries of size 2x2 ft an independent Isolated, electronic LED driver (SMPS based constant current supply) housed in CRCA powder coated sheet of system wattage - 36/40 Watt, Lumen out put- 4000-4300 Lm, THD < 10%, PF > 0.9, having short circuit and surge protection suitable for Armstrong/ Grid ceiling with all connected accessories including making connection with three core PVC insulated, sheathed copper conductor cable of size 23/0.0076 complete all as specified and directed. Make Havells/Syska/Anchor/Wipro or as approved.
64S&F in replacement of Decorative wall mounting fixture with elegant diffuser, Floral blown glass, Metal of holder base, ambience E27, 1x8W, along with LED lamp 8 watt ,complete in specified and as directed.Make Havells/Syska/Anchor/Wipro or as approved.
65S&F in replacement of existing worn out spot light 12 watt of 155 mm dia with Recess mounted pressure die-cast aluminium luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and separate replaceable electronic driver complete with LEDs, in built electronic LED driver and accessories pre-wired up to terminal block including making connection complete all as specified and directed. Make Havells/Syska/Anchor/Wipro or as approved.
66Supply and fixing in replacement of worn out wooden batten/PVC Conduit with Non Metallic Rigid PVC conduit of following size, ISI Marked, conforming to IS 9537 Part III, medium grade including all fittings like bends, elbow reducer, junction boxes, tee bell mouth all fixing accessories such as coupler lock, nuts, saddles pipe hooks etc complete in all respect as specified and directed.
67i)20 mm nominal dia
68ii)25 mm nominal dia
69Supply & fixing in replacement of worn out/rustedsunken box with pressed MS/GI steel terminal boxes of depth not less than 50 mm, flush type of thickness lot less than 1.22 mmof following size alongwith new 3.0 mm thick plastic laminated sheet cover of suitable size including cutting/drilling hole and fixing switches, sockets, fan regulator etc as removed from old sheet and fitted with cadmium plated screw washer and making good to disturbed surface with cement mortar complete in all respect as specified and directed.
70(i)100mm x 100mm
71(ii) 175mm x 100mm
72(iii) 200mm x 150mm
73(iv) 250mm x 200mm
74M& L for repairing of unserviceable Gate lightof any type/makeby replacing burn out/worn-out/ weakLED lamp 25 watt and re- fixing the fitting in position after repair and testingcomplete. Make Havells/Syska/Anchor/Wipro or as approved.
75S&F (in replacement) Gate light post top luminaire with diamond shaped opal diffuser mounted on cast aluminium capsule suitable for 1x15 watt LED including lamp and connection with PVC insulated & sheathed stranded copper conductor cable three core of size 2.5 Sqmm complete all as specified & directed (Make Havells/Syska/Anchor/Wipro or as approved.)
76S&F (in replacement) garden light fitting suitable for LED lamp 1x18 wattincluding LED, light fittings moulded plastic capsule which house ballast, lamp holder, baffles for glare control etc. alongwith GI tubing 50 mm bore light grade - 1.2 RM approx.duly groutedwith required civil/PCC/brick work as in foundation incl connection using suitable bakalite connector & connection with PVC insulated cable with copper conductor of size 1.5 sqmm of length 1 mtr approx from connector to fitting terminal complete all as specified and directed.
77M& L for replacement of Oval shaped post top latern in prismatic finish made up of polycorbonate, suitable up to 27 watt retrofit LED (B-22 base) connection of pole boxto fitting with 1.5 sqmm pvc insulated copper conductor flexible wire and testing complete all as specified and directed make : Havells Havells/Crompton/Wipro/Syska .
78M& L for replacement of Crown shapedpost top latern in smoothing moon finish made up of polycorbonate, suitable up to 27 watt retrofit LED (B-22 base) including connection of pole boxto fitting with 1.5 sqmm pvc insulated copper conductor flexible wire and testing complete all as specified and directed. Make : Havells/Crompton/Wipro/Syska
79S&F in replacement of worn out CFL with enercy efficient rechargeable LED lamp of 7 watt with in built lithium battery of capacity 2000 mAH minimum lument out put 600 Lm or above, based cap-B 22 complete all as specified and directed.Make Havells/Syska/Anchor/Wipro or as approved.
80Ceiling fan/exhaustfan
81M&L for rewinding of stator complete with super enameled copper winding wire of existing gauge/ weight of copper coil, quick varnishing, oiling, greasinginsulating materials including replacement of worn out parts like unserviceable cotter pin, nut, screw, check nuts and bolts as required incl. cleaning of body, and testingof the following size of fans of any make complete all as specified and directed.Note - (A) Fans to be collected by the contractor at their own arrangement from AGE E/M store forrepair/rewinding and to be deposited at same place after making serviceable duly tested. (B) Aditional spare parts as required to make the serviceable of same will be measured and paid separately under respective items of schedule here in below:-
82Ceiling fan of 1200 mm sweep
83Ceiling fan of 1400 mm sweep
84Exhaust fan of 230 mm sweep
85Exhaust fan of 300 mm sweep
86Exhaust fan of 380 mm sweep
87Exhaust fan of 450 mm sweep
88Wall fan/cabin/Pedestal of 400 mm sweep
89Supply & fixing in repair the following items to incorporate the item No. 63.01 to 63.07 as mentioned above :-
90Ball bearing of ceiling/exhaust fan of any size of exactly similar as existing in fan complete all as specified and directed. (Make-NBC/SKF)
91U" shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel etc. suitable to the down rod pipe and connecting complete all as specified and directed.
92Capacitor 2.5 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
93Capacitor 3.15 Mfd, 440 Volt AC complete all as specified and directed. Make - Asian/Usha/Epcos of siemens /Havells or as approved by GE
94PVC insulated, sheathed flexible copper conductor cable in three core of size 23/0.0076 from connector to the ceiling rose complete all as specified and directed.
95Capacitor clip as per existing complete all as specified and directed.
96Canopy for ceiling fan suitable for any sweep/make as required incl. screw complete all as specified and directed.
97M&Lfor Spray painting of stained/rusted/corroded Ceiling fan/Exhaust fan complete body with one coats of synthetic enamel white/smoke gray paint incl writing of MES No over one coat of primer all as specified and directed.
98S&F in replacement of MS louvers shutters on wall suitable for exhaust fan of following sizes incl. suitable size of nut, bolts & washercomplete all as specified and directed.:-
99300 mm sweep
100450 mm sweep
101M&L for servicing of ceiling fans at site, oiling, greasing and checking of fan hook for damage spilt pin, nut bolt, rubber reels and down rod including proving new split pin and replacement of damage nut bolt and down rod complete all as specified and directed. Note: (i)replacement of down rod measure and paid seperately in relevant items
102S&F in replacement Mild steel"Medium grade" 15mm dia pipe down rod of required length with makingsplit, holes, cut etc at both end of pipe as required for hanging of C/fan incl. painting of rod with two coats of synthetic enamel white paint over one coat of primer along with U" shape shackle clamp assembly made out of MS flat iron incl checknut, bolts, screws, washer, split pin, lock nut, rubber reel complete all as specified and directed.
103S&F in repair fan hook suitable for 40 mm dia pipe, made out of MS flat iron size 50x6 mm incl. suitablesize of nut, bolt & washer complete all as specified and directed.
104AC WINDOW/SPLIT TYPE
105Repair/maint of window type AC/split AC any capacity of any make by cleaning and servicing of serviceable parts replacement of wiring kit, knobs & unserviceable parts replacement of air filter made of jute and reassembling the serviceable spare parts etc and testing for smooth functioning and re installation at site or deposit in MES store yard after repair. [Notes : (a) spare parts shall be measured and paid separately under respective items. (b) Replacement of nuts, bolts and washers deemed to be included in unit rate. (c) Minor repair of chesis by brazing/welding work deemed to be included in unit rate.]
106Removing burnt/defective sealed compressor unit of any make from any type of air conditioner window type 1.5 ton capacity by cutting of suction and discharge lines unscrewing the foundation nuts, bolts etc, supply amd fixing of new sealed compressor unit of suitable make as existing by connecting suction and discharge lines with gas welding/brazing work and tightening foundation nuts & bolts etc all as directed
107All as per item No. 78 above but for 1.5 ton Split type Air conditioner [Notes : (a) Capillary, drier, copper tubing etc are inclusive in unit rate. (b) New compressors will be purchased from authorised dealer only. (c) Unserviceable compressor either cut open or sealed unit have to be replaced by new one
108All as per Item No 78 above but for air conditioner window / split type 2 ton capacity
109Repair to Air conditioner window type/Split type 1/1.5/2 ton capacity by testing the leakage in system by filling of Nitrogen gas upto 300 PSIG and repairing of leaking spot/joints with gas welding work, cleaning and flushing out the complete system with gas, supply and replacing of drier/filter, making the complete system leak proof, vacuuming the system and charging of gas as existing andtesting etc complete all as specified & directed (Note : Drier capillary and copper tubing are inclusive in unit rate)
110S&F in replacement of blower Motor 1/5 or 1/6 HP 230V AC, 50 Hz suitable for Air conditioner window type 1.5 ton capacity blower motor complete all as directed and specified
111S&F in replacement of blower Motor 0.2/0.25 HP for Air conditioner split type 1.5 ton/2 ton complete and as directed and specified (Make - GE/Crompton/Polar)
112M&L for repair to blower Motor1/6 HP to 0.25 HPwith super enamelled copper wire of existing size suitable for Air conditioner window type / split type complete all as directed and specified
113M& L for repair to PCB circuit in air conditioner split type all as specified & directed.
114S&F in replacement ofpower contactor 240V AC, 50 Hz 16 - 25 Amps range (Make- L&T/Bhartiya cutler hamme)
115Supply and fixed in replacement of power contactor 415V AC, 50 Hz 16-25 Amps rage (Make - L&T Type MK-I/BCH or as approved)
116M&L for painting of chasis/body of AC with one coat of synthetic enamel paint by spray painting of approved make including preparation of surface and one coat of aluminium paint to outer cover.
117Supply only following spare parts for window type AC capacity 1.5/2 ton : -
118Capacitor 4 mfd
119Running capacitor 36 mfd AC
120Starter capacitor 80/100 mfd
121Relay any make and type as approved
122Over load protector 1022
123Thermostat
124Cooling coil
125Filter pad made of Jute
126Condensers coil
127Selector switch
128Wiring kit
129Front Panel of window AC any make of 1.5/2TR
130Blower
131M&L for Stands for Discharge unit of Split type AC/ Desert coolerstand etc. as per requirement and directed by Engr -in-charge
132S&F in replacement indoor unit of AC 1.5 ton capacity split type of approved make as directed (Note-Old unit to be deposited in MES store yard)
133WATER COOLER
134Dismantling of electric connection and water connection of water cooler opening the condensor fan motor blade, electrical accessories and spare parts of system carefully servicing of serviceable parts replacement of unserviceable parts oiling of fan motor etc reassembling all spare parts incl rewiring of internal connection of water cooler, testing and commissioning complete all as specified. (Note: Worn out or unserviceable spare parts to be replaced shall be measured and paid separately as supply only under respective item.)
135Removing burnt/defective sealed compressor unit of any make from water cooler cap 40 Ltrs/hr by cutting of suction and discharge lines and unscrewing the foundation nuts & bolts etc, supply and fixing new sealed compressor unit Make as existing or equivalent in kirloskar or tecumsehby tightening the foundatopn nuts and bolts and connecting suction and dischrage line with gas welding work etc complete. [Note:- (i) Cost of transportation shall be deemed to be included in the quoted rates. GI fitting damaged while taking out/fixing back water coolers shall be replaced by the contractor at his own cost. (ii) All new compressor shall be purchased from authorised dealer only. (iii) Capillary, drier, filter strainer are inclusive in unit rate. (iv) Old compressor either cut open or sealed have to replaced with new one.]
136All as per item No 95 above but water cooler Cap 60 Ltrs/hr
137All as per item No 95 above but water cooler cap 150 Ltrs/hr.
138M&L for replacement of Rubber hose pipe of 20mm bore with clips for outlet tray of water cooler of length 1.5 Mtr long approx. complete
139M&L for replacement of PVC sheet rubber bedding and lock of top cover of water cooler by screwing/welding MS sheet of top cover complete all as directed
140M&L for replacement of PVC connection rigid type 18” long 15mm bore, with adopter at both ends complete.
141M&L for making the system leak proof and charging of gas Freon 12/22 as required in water cooler of capacity 40/60 Ltr including replacement of drier and capacity tube and testing on load complete all as directed
142All as per item No. 101 above but of capacity 120/150 ltrs.
143M&L for scraping old painted surface of water cooler any capacity and painting with two coats of synthetic enameled paint including writing SM/MES No with black paint with minimum 25 mm size of letters as directed
144M&L for replacement of old condenser fins with new, forced air-cooled including necessary brazing work for water cooler of any capacity including testing for leakage complete.
145S&F in replacement of condenser fan motor of cap 1/35 HP with fan blade all as directed
146M&L for winding of condenser fan motor of cap upto 1/8 HP with super enamelled copper wire of existing size including replacement of bush and fan blade incl painting complete all as directed
147S&F in replacement of push cock/lift cock brass chromium plated 15 mm bore.
148M&L for replacement of flexible PVC pipe of followingsizes for the drainage of waste water of water coolers or concealing the copper tubing of split AC and condensed moisture of air conditions all as directed.
14940mm dia
15050mm dia
15160mm dia
152Deduction and rectification of leakage of storage tank of water cooler by brazing soldering/welding as required at site or work shop testing for leak proof complete all as directed.Note : (a) Nipple adoptor if required deemed to be included in unit rate. (b) Push cock, float valve etc if required will be measured and paid separately. (c) Changing of rubber/plastic packing is incl in unit rate.
153Taking out the drain tray with PVC pipe of water cooler, electroplating (chromium plating) of drain tray after repair by denting/painting and including replacement of new PVC pipe of suitable size and length and refixing back all as directed.
154Supply only the following items for water cooler :-
155Starting capacitor 60/80 mfd
156Running capacitor 10 mfd
157Thermostat
158Relay over load kit
159Relay
160Over load protector 1022
161Wiring kit
162Strainer/filter drum type/pen type
163Door gasket
164Float valve 1/2" including assembly brass made.
165VOLTAGE STABILIZER
166M&L for opening unserviceable automatic voltage stabilizer for repair,detection of fault and its repair cleaning of serviceable parts, replacement/repair of unserviceable or worn out parts soldering of terminal connection and testing after repair, painting with one coat of synthetic enamel paint externally all as specified including sign writing "AGE E/M New Cantt" all as directed any make:-[Note: (a) Replacement of new parts/worn out parts in lieu of unserviceable/worn out parts shall be measured and paid separately. (b) The flexible 3 core cable, 40/.0076, 23/.0076, 70/.0076 to be provided at least 1.5 RM is included in unit rate.]
167Capacity 5 KVA/4 KVA
168Capacity 3 KVA.
169Supply only the following spare parts suitable for automatic voltage stabilizer of any make and capacity :-
170Volt meter (0-300 volts)
171Control relay
172IC controlled circuit for 5KVA/4 KVA
173IC controlled circuit for 3 KVA
174Control transformer
175Low/high voltage cut off and TDR system
176Main transformer for 5 KVA/4 KVA
177Main transformer 3 KVA
1783 pin plug top 16 amp make : Anchor
179M&L for rewinding of boost/buck transformer of stabilizer with copper wire of existing gauge and same number of turn with best quality insulating material including testing complete and refixing back electrically and mechanically all as directed and specified by Engr-in-Charge of following capacity :-
180Capacity 5 KVA/4 KVA
181Capacity 3 KVA
182S&F in replacementof 5 KVA stabilizer 230 volts Single phase (Note-Old to be deposited in MES store yard). (Make : Blue star/Vinitec/Brentford/Automatic Electric)
183WINTER APPLIANCES
184Taking down existing geyser any capacity/ type after suitable disconnecting all electrical and water supply connection, removing geyser to E/M store, opening and dismantling the complete geyser, cleaning all serviceable parts completely including descaling the geyser, for replacing the defective/wornout parts, reassembling the geyser, testing for proper functioning, transporting to& refixingin original location i.e in the same in position, reconnecting the geyser with electricsupply and water supply line and testing complete all as specified and directed. Note :-(i) Parts/sparesrequired for replacement shall be measured and paid separately. (ii) Unit rate quoted shall be deemed to include minor items i.e. nut bolts, screws, lugs etc .
185S&F in repair Heating element Square, threaded/ screwed type 1500 watt ISI markedcomplete all as specified and directed. Make Theeta/ Bajaj/ Hot top/Daspass or equivalent as approved.
186S&F in repair Heating element cup type 1500 watt (ISI marked) complete all as specified and directed.Make - Bajaj/ Dass Pass/ Threeta or equivalent approved.
187S&F in repair Heating element threaded/screwed type 2000 watt (ISI marked) suitable markedcomplete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
188S&F in repair Heating elementcup type 3000 watt (ISI marked) complete all as specified and directed. Make - Bajaj/Theeta/Hot top/ Daspass or equivalent as approved.
189S&F in repair Thermostat suitable for geyser range 20 degree to 80 degree (ISI marked) complete all as specified and directed.Make-Thermoking/TTE,Elcon/ Expo/ Antriksh or equivalent approved.
190S&F in repair PVC connection cotton braided heavy duty with brass union/coupling of length 450 mm with rubber washer suitable for 15 mm pipe complete all as specified and directed..
191S&F in repair Hot water outlet connection made of chromium plated flexible tubing for 15 mm bore pipe complete all as specified and directed.
192S&F in repair Indicator lamp assembly with bulb with long lead suitable for geysers round or square type as sample kept in GE’s office complete all as specified and directed..
193S&F in repair PVC insulated flexible wire three core 2.5 sqmm copper conductor heavy duty complete all as specified and directed..
194S&F in repair Apperture plate assembly suitable for25 ltrs geyserscomplete all as specified and directed.
195S&F in repair Apperture plate assembly uitablefor 50 ltrs geysers complete all as specified and directed.
196S&F in repair Inner copper tank made out of 0.8mm(min.)for 25 ltrs geyser complete all as specified and directed.
197S&F in repair Outer body with red,green indicator and bottom cover as per existing size & shape of capacity 25 ltrs geyser complete all as specified and directed.
198S&F in repair 3 pin 15 amp plug top complete all as specified and directed. Make Anchor or equivalent as approved
199S&F in repair electronic sensor for thermal setting as per sample kept in GE’s office complete all as specified and directed..
200M&L for painting of geysers after scraping, cleaning and preparing surface for painting and painting with two coats of white enameled paint of approved make and sign writing MES No etc complete all as specified and directed for the following capacity :-.
20125 Ltrs capacity
20250 Ltrs capacity
203Repair of leakage of inner tank 25/50 ltr capacity geyser by brazing/soldering, testing including cutting of nut, bolt as required with gas welding cutter and providing new nut, bolts, washers etc complete all as specified and directed.
204S&F in repairs Chromium plated brass stop cock 15 mm bore, screwed down, high pressure with crutch or butterfly handle complete all as specified and directed.
205S&F in repairs MCB DP 32 amp, 230 volt, AC , 10 KAwith indication & enclosure complete all as specified and directed.
206S&F in repairs mild steelfoundation nuts, bolts & washers heavy duty for fixing of geyser including grouting in wall complete all as specified and directed. .
207S&F in repairtwo pin and earth plug and socket sheet metal enclosurewith one single pole MCB 20 amp rating, 240 volt,C" series,10 KA breaking capacity complete all as specified and directed.
208M&L for Non return valve verticletype screwed for both ends with 15mm bore GI pipe.complete all as specified and as directed.
209S&F in repair fusible plug steel nut complete all as specified and directed.
210S&F in repair Timmer suitable for Hevalls geyser (ISI marked) complete all as specified and directed.
211S&F Sheet metal enclosures for distribution board when MCB to be used TPN 4 way 415V with 200Amp rated bus bar,doulle door type with MCCB Amps as incomer and MCB"s as outgoing complete all as specified and as directed.Make ;- Legrand equivalent model of Scheider/Siemens/L&T/Havells.
212M &L for Earthing complete with GI earth plate electrode 600x600x6mm thick buried directly in ground (Earth pit not less than 2.25M deep below normal ground level) with top edge of the plate not less than 1.5m below normal GL. Connected to galvanized earth lead wire 4mm dia by means of nut, bolt, check nut and washersincluding necessary excavation and earth work in soft/loose soil, GI protection pipe light grade 15mm bore for protecting the GI wire mesh funnel alternate layer of charcoal dust, and saltPCC pit 1:3:6 type C1 using 20mm graded stone aggregate and 50mm thick RCC 1:2:4 type BO using 20mm graded stone aggregate cover re-inforced with 8 mm dia MS TMT bars 80mm C/C both ways complete all as specified and shown in Electrical plate No.3 SSR part-1 and connected to the earth point and testing complete all as specified and directed.
213S&F for mirror light fittings 8 Watt LED decorative compact energy efficient luminaire with anti glare diffuser complete.Make-Wipro/ SYSKS/Cromption/Havells
214M&L for repair to light/fan/bell point/socket point/power point/two way point any type by replacing un serviceable worn out wires/condiut clips/sheet/sunken box/switch/socket or any other fault and making good the point serviceable by replacing burnt wire/holder/fittings as required in all respect complete all as directed by Engr-in-charge.(Note-(1) Cost of replacing burnt wire/holder/fittings&fixtures will be measured and paid separately.(2) Contractor will detail two electricians and two helpers and one electrician and one helper will report to JE E/M of PCDA(P) complaint cell daily at 0900 hrs in the morning hours except Sundays and holidays and collect the complaint slip from the respective JEs and attending all the complaints given by JE and completion report will given to the concerned JEs every day at 1700 hrs with out any delay.