Misc. Civil Works On 0.74 Acres Of Land To Facilitate Shifting Of Approach Road Of The Existing Terminal Building. Sh- Construction Of Ug Water Tank And Fire Control Room For Fire And Ac Etc. At Pune Airport Construction Of Ug Water Tank And Fire Control , pune-Maharashtra

Airports Authority Of India has published Misc. Civil Works On 0.74 Acres Of Land To Facilitate Shifting Of Approach Road Of The Existing Terminal Building. Sh- Construction Of Ug Water Tank And Fire Control Room For Fire And Ac Etc. At Pune Airport Construction Of Ug Water Tank And Fire Control . Submission Date for this Tender is 08-10-2022. Road Work Tenders in pune Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

33988754
Misc. Civil Works On 0.74 Acres Of Land To Facilitate Shifting Of Approach Road Of The Existing Terminal Building. Sh- Construction Of Ug Water Tank And Fire Control Room For Fire And Ac Etc. At Pune Airport Construction Of Ug Water Tank And Fire Control
Open Tender
Indian
Maharashtra
pune
08-10-2022

Tender Details

Misc. Civil Works On 0.74 Acres Of Land To Facilitate Shifting Of Approach Road Of The Existing Terminal Building. Sh- Construction Of Ug Water Tank And Fire Control Room For Fire And Ac Etc. At Pune Airport Construction Of Ug Water Tank And Fire Control Room For Fire And Ac Etc. At Pune Airport.

Key Value

Document Fees
INR 1180 /-
EMD
INR 157960.0 /-
Tender Value
INR 78.98 Lakhs /-

BOQ Items

Name of Work: Misc. Civil works on 0.74 acres of land to facilitate shifting of Approach Road of the existing Terminal Building. SH: Construction of UG water tank and Fire control room for Fire and AC etc. at Pune Airport
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-incharge. Hard rock (blasting prohibited)
2Filling available excavated earth (excluding rock) in trenches, plinth,sides of foundations etc. in layers not exceeding 20cm in depth,consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
3Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS:9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level : Concrete of M10 grade with minimum cement content of 220 kg /cum
4Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.Concrete of M30 grade with minimum cement content of 350 kg /cum
5Centering and shuttering including strutting, propping etc. and removal of form for Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
6Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
7Providing and laying integral cement based treatment for water proofing on horizontal surface at all depth below ground level for under ground structures as directed by Engineer-in-Charge and consisting of : (i) Ist layer of 22 mm to 25 mm thick approved and specified rough stone slab over a 25 mm thick base of cement mortar 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound conforming to IS:2645 in the recommended proportion over the leveling course (leveling course to be paid separately). Joints sealed and grouted with cement slurry mixed with water proofing compound. (ii) 2nd layer of 25 mm thick cement mortar 1:3 (1 cement: 3 coarse sand) mixed with water proofing compound in recommended proportions. (iii) Finishing top with stone aggregate of 10 mm to 12 mm nominal size spreading @ 8 cudm/sqm thoroughly embedded in the 2nd layer. Using rough kota stone.
8Providing and laying integral cement based treatment for water proofing on the vertical surface by fixing specified stone slab 22 mm to 25 mm thick with cement slurry mixed with water proofing compound conforming to IS:2645 in recommended proportions with a gap of 20 mm (minimum) between stone slabs and the receiving surfaces and filling the gaps with neat cement slurry mixed with water proofing compound and finishing the exterior of stone slab with cement mortar 1:3 (1 cement : 3 coarse sand) 20 mm thick with neat cement punning mixed with water proofing compound in recommended proportion complete at all levels and as directed by Engineer-in-charge : 22.2.1 Using rough Kota stone
9Taking out existing CC interlocking paver blocks from footpath/ central verge, including removal of rubbish etc., disposal of unserviceable material to the dumping ground, for which payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of Engineer-in-Charge.
10Laying old cement cocrete interlocking paver blocks of any design/ shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. all complete as per the direction of Engineerin-charge. (Old CC paver blocks shall be supplied by the department free of cost).
116 mm cement plaster of mix :1:3 (1 cement : 3 fine sand)
12Providing M.S. foot rests including fixing in manholes with 20x20x10cm cement concrete blocks 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) as per standard design :
13Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 80 mm nominal dia Pipes
14Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm nominal dia Pipes
15Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 100 mm nominal dia Pipes
16Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge.80 mm nominal dia Pipes
17Providing and fixing in position pre-cast R.C.C. manhole cover and frame of required shape and approved quality L D- 2.5 Rectangular shape 600x450 mm internal dimensions
18Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
19Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings, this included jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. (External work).200 mm nominal inner dia. Pipes (CPVC SCH-80)
20Design Consultancy WorkProviding Engineering Structural Consultancy Services for Design of RCC Under ground water tank for 5.0 Lac Ltrs including Structural & Engineering design specifying RCC foundation, for electrical installation etc. with all relevant calculation sheet, vetting of both design & drawing by I.I.T/NIT/Govt. Engg. college including issue of "Good for Construction drawings", revision of drawing as per changes during execution & final "As Built Drawing" complete with vetting and not limited to any other details related to consultancy work which are essential for successful execution of work etc. complete as per direction and satisfaction of Engineer incharge. Note:-1) The Agency shall submit the conceptual drawings by using servicesof consultants for approval from EIC. Nothing extra is payble for submitting conceptual drawings till the satisfaction & approval of EIC.2) After getting approval, the detailed working structural drawings for each and every details should be submitted as the per satisfaction and direction of EIC.3) The payment under this item shall be made in parts in proportion to amount of work.
Disclaimer :