| Sl. No. | Item Description |
| 1 | AB Cablingworks ,11 KV overhead line Ab Cabling Works as per technical specification, approved drawings and scope of work. LTAB Cable on poles [Size: (3x95 Sq, mm ) (total Qty 62 KMs) |
| 2 | LT AB Cable on poles [Size: (3x95 Sq, mm ) {inclusive 3% sagging & wastage) |
| 3 | Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 4 | Muffs with concerete filling |
| 5 | Stay Set Complete |
| 6 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 7 | Full Clamp for stay |
| 8 | Anchoring Assembly for LT |
| 9 | Suspension Assembly for LT |
| 10 | Facade Hooks for LT |
| 11 | Distribution Boxes as per T.S. |
| 12 | Piercing Connector as per TS |
| 13 | Cable for SMDB 3.5Core X 35sqmm |
| 14 | T-Jointing kit |
| 15 | LTEarthing set complete (preferbly coil earthing) |
| 16 | Red Oxide |
| 17 | Aluminium paint |
| 18 | HT, UG armoured cable Cable [Size: (3x120 Sq, mm)Total 4.5 Kms |
| 19 | 11 kV XLPE Cable [Size: (3x120 mm²) {inclusive 1% wastage)] |
| 20 | 11 kV Cable Straight Through Jointing Kit [Size: 3x120 mm²] |
| 21 | 11 kV Cable Indoor Termination Kit [Size: 3x120 mm²] |
| 22 | 11 kV Cable Outdoor Termination Kit [Size: 3x120 mm²] |
| 23 | RCC Hume pipe. |
| 24 | RCC collar pipe |
| 25 | RCC cable cover (2 feet long) |
| 26 | Sand Bag (50 Kg) |
| 27 | Route and Joint indicating stone |
| 28 | Inspection Chamber |
| 29 | GI Pipe earthing 40 mm x 2.5/3 m \"B\" class |
| 30 | Pipe HDPE Size 150 mm |
| 31 | Lug AL Crimping 70 SQMM XLPE Single HOLE |
| 32 | Flat GI Size 25x6 mm |
| 33 | Cleat HDPE for Cable Support |
| 34 | G.I. Pipe 100 mm DIA \"B\" CLASS |
| 35 | Flat GI Size 50x6 mm |
| 36 | Channel MS Size 75x40 mm |
| 37 | Restoration charges to be paid to authoroties such as local bodies, HPPWD, NHAI etc. |
| 38 | HT, XLPE AB Cable [Size: (3x240Sq, mm) Total 2 Kms |
| 39 | HT , AB Cable [Size: (3x240Sq, mm ) {inclusive 1% sagging & wastage) |
| 40 | Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 41 | Muffs with concerete filling |
| 42 | Stay Set Complete |
| 43 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 44 | Full Clamp for stay |
| 45 | X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length [600 mm] |
| 46 | Half Clamp for Cross Arm |
| 47 | Anchoring Assembly for HT |
| 48 | Suspension Assembly for HT |
| 49 | Facade Hooks for HT |
| 50 | Heat Shrinkable Straight Through Jointing Kit |
| 51 | Cable Termination kit |
| 52 | T-Jointing kit |
| 53 | HT Earthing set complete (preferbly coil earthing) |
| 54 | Red Oxide |
| 55 | Aluminium paint |
| 56 | HVDS |
| 57 | Conversion of LT line to 11 KV line -11kv line on Steel Tublar pole with DOG Conductor -100 Sq. mm Total 178 Kms |
| 58 | ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3F and inclusive 3% (Sag, Jumpering and wastage} |
| 59 | Steel Tubular Poles (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro\" and 3 No. Double Pole Dead End Structures) |
| 60 | Muffs with concerete filling |
| 61 | Run Thro\" Structures (? Formation): on Single Pole Structures (Adopt Eight (8) No. Run-through Structures per Km) - |
| 62 | Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure |
| 63 | Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures |
| 64 | Pole Top Bracket [MSCI:100x50x6 mm- 100 mm] |
| 65 | 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure |
| 66 | 11kV GI Pin. |
| 67 | Dead End Structures: (Adopt three (3) No. per Km) on Double Pole (Prefer along road side) |
| 68 | Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No. |
| 69 | X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No. |
| 70 | X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation |
| 71 | Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides) |
| 72 | 11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure |
| 73 | HT Stay / Guy Arrangement |
| 74 | Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures) |
| 75 | Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set) |
| 76 | Earthing |
| 77 | HT Earthing set complete (REC Constr. Stand. J-1) |
| 78 | Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m |
| 79 | Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m} |
| 80 | Eye Hook for earth wire |
| 81 | Earth Wire Clamp |
| 82 | MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing |
| 83 | Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro\" structure: 2 No ] |
| 84 | Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro\" structure: 2 No] |
| 85 | Danger Plate (250X200X1.6 mm) |
| 86 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)] |
| 87 | Barbed Wire |
| 88 | Red Oxide |
| 89 | Aluminium Paint |
| 90 | New 11kv Line - 11kv line on steel tublar pole with DOG conductor Total 110 Kms |
| 91 | ACSR 6/1/4.72 (50mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} |
| 92 | Steel Tubular Poles (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro\" and 3 No. Double Pole Dead End Structures) |
| 93 | Muffs with concerete filling |
| 94 | Run Thro\" Structures (? Formation): on Single Pole Structures (Adopt Eight (8) No. Run-through Structures per Km) - |
| 95 | Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure |
| 96 | Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures |
| 97 | Pole Top Bracket [MSCI:100x50x6 mm- 100 mm] |
| 98 | 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure |
| 99 | 11kV GI Pin. |
| 100 | Dead End Structures: (Adopt three (3) No. per Km) on Double Pole (Prefer along road side) |
| 101 | Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No. |
| 102 | X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No. |
| 103 | X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation |
| 104 | Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides) |
| 105 | 11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure |
| 106 | HT Stay / Guy Arrangement |
| 107 | Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures) |
| 108 | Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set) |
| 109 | Earthing |
| 110 | HT Earthing set complete (REC Constr. Stand. J-1) |
| 111 | Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m |
| 112 | Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m} |
| 113 | Eye Hook for earth wire |
| 114 | Earth Wire Clamp |
| 115 | MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing |
| 116 | Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro\" structure: 2 No ] |
| 117 | Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro\" structure: 2 No] |
| 118 | Danger Plate (250X200X1.6 mm) |
| 119 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)] |
| 120 | Barbed Wire |
| 121 | Red Oxide |
| 122 | Aluminium Paint |
| 123 | Installation of New DT Total 765 Nos |
| 124 | Distribution Transformer (Ordinary), 11/0.4 kV,10 KVA |
| 125 | Distribution Transformer (Ordinary), 11/0.4 kV,16 KVA |
| 126 | Distribution Transformer (Ordinary), 11/0.4 kV,25 KVA |
| 127 | Distribution Transformer (Ordinary), 11/0.4 kV,63 KVA |
| 128 | Distribution Transformer (Ordinary), 11/0.4 kV,100 KVA |
| 129 | Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 130 | Muffs with concerete filling |
| 131 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line |
| 132 | MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA\"s |
| 133 | X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 134 | Transformer Bed, Belting & Knee Bracing |
| 135 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed |
| 136 | X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer] |
| 137 | MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 138 | MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos |
| 139 | MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing |
| 140 | Transformer LT Distribution Box and GO Switch fixing Assembly |
| 141 | MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 142 | MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos |
| 143 | GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm |
| 144 | GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type |
| 145 | D.O Fuse Unit |
| 146 | Lightening Arrester, 9 kV Station Class(Porcelain Type) |
| 147 | Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 148 | Stay set complete |
| 149 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 150 | Pipe Earthing Set |
| 151 | LT Distribution Panel Box with MCCB(50A, 25 kA, 4P) |
| 152 | LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) |
| 153 | LT Distribution Panel Box with MCCB(160A, 25 kA,1No) and outgoing 2 nos 100A, 25kA MCCB |
| 154 | Half Clamp (M.S. Flat 50X6 mm) |
| 155 | Full Clamps (M.S. Flat 50X6 mm) |
| 156 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)] |
| 157 | Aluminium Thimble |
| 158 | Aluminium Thimble |
| 159 | Danger Plate |
| 160 | Barbed Wire |
| 161 | Red Oxide paint. |
| 162 | Aluminium Paint. |
| 163 | LT Switched Capacitors 9- KVAr for 25 KVA(rate per KVAr) |
| 164 | LT Switched Capacitors 9- KVAr for 63 KVA(rate per KVAr) |
| 165 | LT Switched Capacitors 9- KVAr for 100 KVA(rate per KVAr) |
| 166 | LT Cable (3.5 Core) 50 mm² |
| 167 | LT Cable (3.5 Core) 95 mm² |
| 168 | LT Cable (3.5 Core) 185 mm² |
| 169 | Conversion of bare conductor with AB Cabling 3x70 Sq. mm Total 142 Kms |
| 170 | LT AB CableCable on poles [Size: (70 mm²) x 1 Cables {inclusive 3% sagging & wastage) |
| 171 | Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 172 | Muffs with concerete filling |
| 173 | Stay Set Complete |
| 174 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 175 | Full Clamp for stay |
| 176 | Anchoring Assembly for LT |
| 177 | Suspension Assembly for LT |
| 178 | Facade Hooks for LT |
| 179 | Distribution Boxes |
| 180 | Piercing Connector as per TS |
| 181 | Cable for SMDB 3.5Core X 35sqmm |
| 182 | T-Jointing kit |
| 183 | LTEarthing set complete (preferbly coil earthing) |
| 184 | Red Oxide |
| 185 | Aluminium paint |
| 186 | Feeder bifurcation |
| 187 | New 11kv line on 11mtr. STP pole with DOG Conductor -100 Sq. mm Total 20 Kms |
| 188 | ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} |
| 189 | Steel Tubular Poles (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro\" and 3 No. Double Pole Dead End Structures) |
| 190 | Muffs with concerete filling |
| 191 | Run Thro\" Structures (? Formation): on Single Pole Structures (Adopt Eight (8) No. Run-through Structures per Km) - |
| 192 | Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure |
| 193 | Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures |
| 194 | Pole Top Bracket [MSCI:100x50x6 mm- 100 mm] |
| 195 | 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure |
| 196 | 11 KV GI Pin |
| 197 | Dead End Structures: (Adopt three (3) No. per Km) on Double Pole (Prefer along road side) |
| 198 | Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No. |
| 199 | X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No. |
| 200 | X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation |
| 201 | Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides) |
| 202 | 11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure |
| 203 | HT Stay / Guy Arrangement |
| 204 | Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures) |
| 205 | Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set) |
| 206 | Earthing |
| 207 | HT Earthing set complete (REC Constr. Stand. J-1) |
| 208 | Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m |
| 209 | Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m} |
| 210 | Eye Hook for earth wire |
| 211 | Earth Wire Clamp |
| 212 | MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing |
| 213 | Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro\" structure: 2 No ] |
| 214 | Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro\" structure: 2 No] |
| 215 | Danger Plate (250X200X1.6 mm) |
| 216 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)] |
| 217 | Barbed Wire |
| 218 | Red Oxide |
| 219 | Aluminium Paint |
| 220 | Cabling of LT line with AB Cable 3X95 Sq. mm. Total 5 Kms |
| 221 | LT AB Cable/XLPE Cable on poles [Size: (95 sqmm arial bunched cable) x 1 Cables {ainclusive3% sagging & wastage) |
| 222 | Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 223 | Muffs with concerete filling |
| 224 | Stay Set Complete |
| 225 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 226 | Full Clamp for stay |
| 227 | Anchoring Assembly for LT |
| 228 | Suspension Assembly for LT |
| 229 | Facade Hooks for LT |
| 230 | Distribution Boxes |
| 231 | Piercing Connector as per TS |
| 232 | Cable for SMDB 3.5Core X 35sqmm |
| 233 | T-Jointing kit |
| 234 | LTEarthing set complete (preferbly coil earthing) |
| 235 | Red Oxide |
| 236 | Aluminium paint |
| 237 | New Distribution transformers Total 10 Nos |
| 238 | Distribution Transformer (Ordinary), 11/0.4 kV,63 KVA |
| 239 | Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 240 | Muffs with concerete filling |
| 241 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line |
| 242 | MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA\"s |
| 243 | X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 244 | Transformer Bed, Belting & Knee Bracing |
| 245 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed |
| 246 | X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer] |
| 247 | MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 248 | MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos |
| 249 | MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing |
| 250 | Transformer LT Distribution Box and GO Switch fixing Assembly |
| 251 | MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 252 | MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos |
| 253 | GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm |
| 254 | GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type |
| 255 | D.O Fuse Unit |
| 256 | Surge Arrester, 9 kV Station Class(Porcelain Type) |
| 257 | Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 258 | Stay set complete |
| 259 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 260 | Pipe Earthing Set |
| 261 | LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) |
| 262 | Half Clamp (M.S. Flat 50X6 mm) |
| 263 | Full Clamps (M.S. Flat 50X6 mm) |
| 264 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)] |
| 265 | Aluminium Thimble |
| 266 | Aluminium Thimble |
| 267 | Danger Plate |
| 268 | Barbed Wire |
| 269 | LT Cable (3.5 Core) 95 mm² |
| 270 | Red oxide paint |
| 271 | Aluminium Paint. |
| 272 | LT Switched Capacitors 27- KVAr for 63KVA(rate per KVAr) |
| 273 | New LT Lines- 3phase -4 wire with rabbit conductor=-50 Sq. mm Total 5 kms |
| 274 | ACSR 6/1/3.35 (50mm²) inclusive 3% sagging & wastage |
| 275 | Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) (with Ruling Span 67 m) |
| 276 | Muffs with concerete filling |
| 277 | Angle Iron (75x75x6) [Length- 1.50 Mtr + 0.02 Mtr] |
| 278 | Shackle Insulator (16 kN) |
| 279 | D-Iron (U- Clamps) |
| 280 | Earth Knob |
| 281 | LT Stay Set |
| 282 | Stay Wire (7/3.15 mm) (6.0 kg Per Stay Set) |
| 283 | Kit KatI.C. |
| 284 | Full Clamps [ 2 No for A.I + 1 No for Stay Set] |
| 285 | Earthing Set complete |
| 286 | Earth wire (GI, 8 SWG) {Additional 1% (Sag and wastage)} @ 0.102 kg/m |
| 287 | Spool Tie |
| 288 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)] |
| 289 | Red oxide paint. |
| 290 | Aluminium Paint |
| 291 | Spiral PVC Spacer |
| 292 | Feeder Segrigation works |
| 293 | New 11kv line on 11 mtr. STP pole with DOG Conductor -100 Sq. mm Total 30 Kms |
| 294 | ACSR 6/1/4.72 (100mm²) {Includes 3 conductor lengths for 3F and Additional 1% (Sag, Jumpering and wastage} |
| 295 | Steel Tubular Poles (11 m, Working Load > 227 kgf/m²) (with Ruling Span 90 m, 8 No. Run thro\" and 3 No. Double Pole Dead End Structures) |
| 296 | Muffs with concerete filling |
| 297 | Run Thro\" Structures (? Formation): on Single Pole Structures (Adopt Eight (8) No. Run-through Structures per Km) - |
| 298 | Cross Arm: [Channel Iron (100x50x6 mm), Length: 1270 mm i/ctolerance of 100 mm either side) x 8 structure |
| 299 | Angle Iron (50x50x6 mm), Length: 750 mm x 2 No. x 8 structures |
| 300 | Pole Top Bracket [MSCI:100x50x6 mm- 100 mm] |
| 301 | 11 kV Pin Insulators (Porcelain, 12 kV, 10 KN): 3 No per pole structure |
| 302 | 11 KV GI Pin |
| 303 | Dead End Structures: (Adopt three (3) No. per Km) on Double Pole (Prefer along road side) |
| 304 | Belt Set - MS Angle Iron: 50x50x6, Length :1800 mm x 2 No. |
| 305 | X-Bracing Set - MS Angle Iron: 50x50x6, Length: 2125 mm x 2 No. |
| 306 | X-Arm (Horizontal) - MS Channel Iron: 100X50x6, Length: 2340 mm x 2 No.] ? Formation |
| 307 | Discs insulator sets on Dead End structures (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) x (3 No. conductors) x (2 No. sides) |
| 308 | 11 kV Pin Insulators (Porcelain, 12 kV, 10 kN): 3 No per double pole structure |
| 309 | HT Stay / Guy Arrangement |
| 310 | Stay set complete in all respect (1No. / Single Pole , 4 No. / Double Pole Structures) |
| 311 | Stay Wire (7/3.15 mm) (10.0 kg Per Stay Set) |
| 312 | Earthing |
| 313 | HT Earthing set complete (REC Constr. Stand. J-1) |
| 314 | Single Continous Earth wire (GI, 8 SWG) {alongwith 2 wire lengths for avg. one road crossing @ 20 m and Additional 1% (Sag and wastage)} @ 0.102 kg/m |
| 315 | Cross Lacings (GI, 8 SWG) [ 2.2 m x 9 Nos @ 2 m spacing] {0.102 kg/m} |
| 316 | Eye Hook for earth wire |
| 317 | Earth Wire Clamp |
| 318 | MS Channel Iron: 75x40x6, Length : 2400 mm for Road crossing |
| 319 | Half clamps: [On Double Pole Dead End structure: 4 No; On Run Thro\" structure: 2 No ] |
| 320 | Full clamps: [On Double Pole Dead End structure: 4 No, Single Pole Run Thro\" structure: 2 No] |
| 321 | Danger Plate (250X200X1.6 mm) |
| 322 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)] |
| 323 | Barbed Wire |
| 324 | Red Oxide |
| 325 | Aluminium Paint |
| 326 | New Distribution transformers Total 20 Nos |
| 327 | Distribution Transformer (Ordinary), 11/0.4 kV,63 KVA |
| 328 | Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 329 | Muffs with concerete filling |
| 330 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for incomer line |
| 331 | MS Angle Iron (50X50x6 mm), Length: (2800 mm) x1 Nos for LA\"s |
| 332 | X-Arm: [Channel Iron (75x40x6 mm), Length : (2800 mm X 4 Nos] for supporting DO fuse unit & GO switch |
| 333 | Transformer Bed, Belting & Knee Bracing |
| 334 | X-Arm: [Channel Iron (100x50x6 mm), Length : 2800 mm X 2 Nos] for Transformer Bed |
| 335 | X-Arm [Channel Iron (100x50x6 mm), Length : (460mm) x 2 Nos for supporting Main Channel of Transformer] |
| 336 | MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 337 | MS Angle Iron (35X35x5 mm), Length : (460 ) x 2 Nos |
| 338 | MS Angle Iron (50X50x6 mm), Length : (950 mm) x 2 Nos for Bed Knee Bracing |
| 339 | Transformer LT Distribution Box and GO Switch fixing Assembly |
| 340 | MS Angle Iron (50X50x6 mm), Length : (2800 mm) x 2 Nos |
| 341 | MS Angle Iron (50X50x6 mm), Length : (450 mm) x 1 Nos |
| 342 | GO Switch Handle Supporting: [Channel Iron (75x40x6 mm), Length : 460 mm |
| 343 | GO AB Switch Unit (11kV, 400A, 25 KA ) Tripple pole O/D type |
| 344 | D.O Fuse Unit |
| 345 | Surge Arrester, 9 kV Station Class(Porcelain Type) |
| 346 | Discs insulator sets (comprising 1 No. Disc: ^^(Porcelain, BS, 12 kV, 90 kN) including Dead End Clamps etc.) |
| 347 | Stay set complete |
| 348 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 349 | Pipe Earthing Set |
| 350 | LT Distribution Panel Box with MCCB(100A, 25 kA, 4P) |
| 351 | Half Clamp (M.S. Flat 50X6 mm) |
| 352 | Full Clamps (M.S. Flat 50X6 mm) |
| 353 | Nuts and Bolts of Various Sizes (Galvanised / Coated) [Preferably 16 mm F or more(with flat and spring washers)] |
| 354 | Aluminium Thimble |
| 355 | Aluminium Thimble |
| 356 | Danger Plate |
| 357 | Barbed Wire |
| 358 | LT Cable (3.5 Core) 95 mm² |
| 359 | Red oxide paint |
| 360 | Aluminium Paint. |
| 361 | LT Switched Capacitors27- KVAr for 63 KVA(rate per KVAr) |
| 362 | Cabling of LT line with AB Cable 3X95 Sq. mm.Total 10 Kms |
| 363 | LT AB Cable/XLPE Cable on poles [Size: (70 mm²) x 1 Cables {inclusive 3% sagging & wastage) |
| 364 | Steel Tubular Poles (9 m, Working Load > 200 kgf/m²) |
| 365 | Muffs with concerete filling |
| 366 | Stay Set Complete |
| 367 | Stay Wire (7/3.15 mm) (7.0 kg Per Stay Set) |
| 368 | Full Clamp for stay |
| 369 | Anchoring Assembly for LT |
| 370 | Suspension Assembly for LT |
| 371 | Facade Hooks for LT |
| 372 | Distribution Boxes |
| 373 | Piercing Connector as per TS |
| 374 | Cable for SMDB 3.5Core X 35sqmm |
| 375 | T-Jointing kit |
| 376 | LTEarthing set complete (preferbly coil earthing) |
| 377 | Red Oxide |
| 378 | Aluminium paint |
AI Tender Summary
Tender Timeline
Tender Published
Tender notice published.
CompletedBid Submission Deadline
Online submission via eProcurement portal.
CompletedBid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender