|
| 1 | Rough excavation not exceeding 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 2 | Materials and Labour for plain cement concrete (1:2:4) type B-2 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified and directed. |
| 3 | M & L for reinforced cement concrete (nominal mix) type B-1 (1:2:4) (20mm graded stone aggregate) in columns, pillars, piers etc, complete all as specified and directed. |
| 4 | Supply and fix mild steel TMT bars 10 mm dia. and over, cut to length, bend to shape required including cranking, bending spirally for hopping for columns,hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia. or securing with clips , complete all as specified and directed |
| 5 | Supply and fix mild steelTMT bars 6 to 8mm dia, cut to length bent to shape required including cranking, bending spirally for hoping for columns, hocking, ends and binding with and incl MS wire (appealed) not less than 0.9 mm dia,complete all as specified and directed. |
| 6 | M&L for returning ,filling including spreding,levelling watering and well raming in layer n exc 25 cm complete all as specified and directed. |
| 7 | M & L for removing excavated soil n.exc 50m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 8 | M&L for brickwork with subclass `B\" bricks old size bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6), complete all as specified and directed |
| 9 | M&L for 15 mm thick rendering in cement mortar (1:4)mixed with water proofing compound in top layer as per manufacturer\"s instructions finished even and smooth without using extra cement complete all as specified and as directed. (Note : Integral water proofing compund shall be measured and paid separtely). |
| 10 | M&L for 15mm thick rendering in cement mortar (1:6) on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement.complete all as specified and as directed. |
| 11 | Supply only integral water proofing compound. |
| 12 | M&L for prepration of newly plastered surface andappplying two coatsof exterier acrylic paint (wheather coats) over 1mm thick wall care putty etc complete all as specified and as directed. |
| 13 | M&L for preparation of new plastered surfaces of wall and appying two coats of oil bound distemper over3mm thick wall care putty complete all as specified and as directed. |
| 14 | Supply and fix Steel windows with side hung shutters (minimum wt. of steel section should be 1.42 kg/M) including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded,including making good disturbed surfaces as per existing specfication complete all as specified and directed. complete all as specified and directed. |
| 15 | Supply and fix Steel windows with side hung shutters(minimum wt. of steel section should be 1.42 kg/M) including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded,including making good disturbed surfaces as per existing specfication complete all as specified and directed. complete all as specified and directed. |
| 16 | Supply and Fix,steel ventilator with top hung shutter (minimum wt. of steel section should be 1.42 kg/M) including hinges, steel peg stay, complete with glazing bars, dovetailed or welded, including making good disturbed surfaces as per existing specfication complete all as specified and directed. |
| 17 | Supply and Fix,steel ventilator with top hung shutter (minimum wt. of steel section should be 1.42 kg/M) including hinges, steel peg stay, complete without glazing bars, dovetailed or welded, including making good disturbed surfaces as per existing specfication complete all as specified and directed. |
| 18 | S&F factory made solid PVC door frame of size 50mmx47mm made out of 5 mm plain colour PVC sheet with mild steel square tube complete as per manufacturer specification & drawing complete all as specified and directed. |
| 19 | S&F factory made solid panel PVC door shutter 30 mm thick (stiles) consisting of frame made out of mild steel tubes for top & bottom rails. Mild steel frame shall be covered with heat moulded plain colour PVC \"C\" channel havinga PVC sheet strip of 20 mm with stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side & as gap inserted for top rail and botttom rail, panelling of plain colour PVC sheet to be fitted in the mild steel frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement fixing in the frame at site as per specification ,drawing completeall as specified and directed . |
| 20 | Materials and Labour for mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290, Grade E-165, complete all as specified and directed. |
| 21 | S&F galvanised mild steel wire cloth,0.56mm nominal dia of wire and average width of aperture 1.18mmand fixed with tinned tacks, or galvanised wire staples for wooden/steel frame.complete all as specified and directed. |
| 22 | Material and Labour for applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer on new steel and iron surfaceexceeding 10 cm in width or girth including preparation of surfaces complete all as specified and directed. |
| 23 | S&F pressed steel frames, size 125 x 60mm, (minimum wt. of steel section should be 1.90 kg/M) for doors and window with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc. complete as specified and directed. |
| 24 | S&F 35 mm thick plain framed, factory made panelled shutter (second class hard wood rails & styles) (two panel) with lock rail and panel of 9 mm B.W.P. commercial ply or 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS : 1003 (Part I), kiln seasoned and chemically pressure treated complete all as specified and directed. |
| 25 | S&F factory made Glazed and skeleton shutters, 30 mm thick second class hardwood, open rebated and prepared to receive glass, gauze, etc. divided into squares, with plain, chamfered or rounded, mitred and rebated sash bars, any numbers, edges of framing plain, chamfered or rounded. fitted with cut and mitred beads for securing glass, etc.; sizes of me-mbers of shutters as specified in SSR Part I, Section 8, clause 8.24 (a); supplied and fitted to chowkats.complete all as specified and directed. |
| 26 | S&F1st class hard woodsmall fittings such asbrackets of any type, latchand hinge blocks, shapeddoor and window stopsand the like, including allnecessary\" labours; articles n exc 200 cu. cm each.complete all as specified and directed. |
| 27 | S&F stainless steel butt hinges, medium weight, and fixed with screws or with welding to existing MS frames, 75 mm size, ISI marked, complete all as specified and directed. |
| 28 | S&F aluminium handles, cast type anodized of size 125 mm, ISI marked, complete all as specified and directed. |
| 29 | S&F aluminium, anodized barrel tower bolts of extruded section and fixed, 150 mm long, dia of bolt not less than 10 mm, ISI marked, complete all as specified and directed. |
| 30 | S&F aluminium anodised barrel tower bolts of extruded section 200mm long all as specified and as directed. |
| 31 | S&F300mm, ordinary mild steel rat tail rod pattern springs including roller and roller plate etccomplete all as specified and directed. |
| 32 | M&L for preparation of new wooden surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 33 | S&F 18/19mm thick prelaminated particle board medium density flat pressed, single layer type with BWR type adhesive fixed with screws to timber frame work complete all as specified and directed. |
| 34 | S&F teak wood extra over lipping 6mm thick around 18/19mm veneered particle board,complete all as specified and directed. |
| 35 | S&F continuous (piano) hinges/channel mild steel, bright finish or electrogalvanised Width of flaps (when open) in 40 mm complete all as specified and directed. |
| 36 | M&L for non-skid ceramic,straight cut/joint free, 7-8 mm thick colored tiles, area of each tile exceeding 0.11 Sq.m but not exceeding 0.18 Sq.m, in floorsetc. over andincluding 15 mm thick cement mortar (1:6) screed, set and jointed with grey cement slurry & pointed with grout of matching shade, , complete all as specified and directed.Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE. |
| 37 | M&L for glazedceramic coloured tiles in vertical surfaces of size 350x250x7mm/450x350x7mm thick quality not less than group II, straight edge, k, as on skirting , dados, walls etc set and jointed in neat cement slurry and pointed in white cement with pigment to match the shade of tiles over and including 10mm thick rendering in cement mortar (1:4),complete all as specified and directed.Note: Design, shade and pattern of fixing of tiles shall be as directed and approved by GE |
| 38 | S&F pre-painted, galvalume aluminium zinc coating GI based corrugated steel sheet, 0.50 mm thick of any colour, having tensile strength of 550 Mpa, as in roof covering/cladding to wall, fixed with self-tapping screws, complete all as specified and directed. |
| 39 | S&F pre-painted galvanized aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 40 | S&F galvanized corrugated mild steel sheeting 0.63 mm thick with two corrugation side lap fixed with coach screws and washers, in roofs, walls etc. with grade of zinc coating 275 fixed with L-type or J-type or cranked hook bolts in roofs complete all as specified and directed. |
| 41 | S&F roof trusses (framed), trussed purlins crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle channel or flat sections) including distance pieces, cleats etc. Fe-410-W (Gde-E-250) quality-A complete all as specified and directed. |
| 42 | S&F Non asbestos fiber cement building boards 4mm thick fixed with screws in ceiling toGI grid frame work for false ceiling Gl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat withfixing arrragement and applying two coats of Oil bound distmper over a coat of wall care putty to obtained smoothness of surface completeall as specified and as directed by Engineer-in-charge. |
| 43 | S&F 3mm thick sheet glass ordinary quality with oil putty in square n. exc. 0.50 sqm in each pane.complete all as specified and directed. |
| 44 | S&F 4mm thick figured glass, pin headed type and glazing with oil putty in square n.exc 0.5 sqm in each pane complete all as specified and directed. |
| 45 | M&L for 75mm thickPCC(1:3:6), type C-2, (using 40 mm graded stone aggregate) as in plinth protection and finished the surface even and smooth without using extra cement,complete all as specified and directed. |
| 46 | M&L for PCC 1:3:6 type C-1(using 20 mm graded stone aggregate) as in bed block for fixing of hold fast ,filling concrete in steel frame,gaps in between glazed & flyproof steel window cills railing upto 60 mm in height etc including necessary form work as requiredcomplete all as specified and as directed. |
| 47 | M&L for Providing and laying 60mm thick factory madehamfered edge cement concrete paver block of M-35 grade with approved colour,design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick pacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer ughvibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand set and jointed in CM (1:4) with grey cement and pigment complete all as specified and as directed. |
| 48 | S&F25mmGun-metal, globe or gate valveswith iron wheel head, screwed both ends for iron pipe etc complete all as specified and directed. |
| 49 | S&Fvitreous China Urinal, Half stall type, whiteincluding providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe. (Exclusive of fixing supply pipe to flushing cistern, trap and waste pipe) |
| 50 | S & F wash basins, vitreous china, white, flat back, size 550 mm X 400 mm with and including cast iron brackets (embedded in wall upto 110 mm depth with and including cement concrete M15 (Nominal Mix) using 20 mm nominal size graded crushed stone aggregate or fixing on wall with and including rawl plug and screws), 32 mm nominal size, copper alloy, nickel chromium plated finish waste fittings, including painting of fittings and brackets, sealing gap between wall and basin with silicone sealant, cutting and making good the walls wherever required and connecting to supply pipes, waste pipes, waste fittings etc. with silicone sealant ,complete all as specified and as directed. |
| 51 | S&F 1000 Ltr capacity rotational moulded polyethylene water storage tanks (Cylindrical, vertical with closed top with three layered) confirming to relevent IS complete including provision of all inlet outlet overflow and drain pipe fittingcompleteall as specified and directed by Engineer in Charge. |
| 52 | S&FPVC valve less syphonic action type flushing cistern low level white with PVC in let ball valve, float and handle, 10 ltrs capacity and connection to pipes set with concrete and making good to floor complete all as specified and directed. |
| 53 | S&Fvitreous China Squatting pan ‘Orissa’ pattern, size 580 X 440mm, white, with integral foot rests and with ‘P’ or ‘S” trap, (excluding flushing cistern and flush pipe) including connection to trap and to flushing pipe, etc and including provision of lime concrete bedding and make good the disturbed surface, complete all as specified and directed. |
| 54 | S&F PVC (SWR) pipes of 75 mm dia single socketed in any length with rubber ring joints fixed to walls, including with clamps etc, complete and jointed complete all as specified and directed. |
| 55 | S&F15 mm bib tap,fancy type chromium plated with crutch or butterfly handle, screwed down, long body with flange ,screwed for iron pipe or for brass ferrule, complete all as specified and directed |
| 56 | SS&F stop valves, cast copper alloy , fancy type, chromium plated, screwed down, high pressure with long shank and cup (concealed type), screwed both ends for steel pipe of for unions, 15 mm bore, complete all as specified and directed. |
| 57 | S&F angle stop valves 15mm dia, cast chromium plated, screwed down, high pressure, screwed both ends for iron pipe and fixed, chromium plated with long shank and cup (concealed type),complete all as specified and directed. |
| 58 | S&F PVC connection 15 mm size with PTMT nuts of length 450mm complete all as specified and directed. |
| 59 | S&F15 mm bore pillar taps, cast copper alloy, withcapstan heads,chromium plated,screwed down highpressure, with or without lettered \"Hot\" or \"Cold\" withlong screwed shanks and fly-nuts,screwed for iron pipe and fixed,fancy type suitable for 15 mm bore pipe, complete all as specified and as directed. |
| 60 | S & F Unplasticised PVC pipes of pressure rating 10 kgf/cm2 fixed complete to walls, ceilings or in floors etc., any type of pipewith bore of pipe 25 mm dia..complete all as specified and directed. |
| 61 | S&F 32mm dia PVC waste pipe 800mm long complete all as specified and directed. |
| 62 | S&Fdouble action floor spring hydraucally regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box,main body with stainless steel cover governing pivot made of brass other parts made of mild steel heavy duty complete all as specified and directed. |
| 63 | Material and labour for point wiring for one light/fan/call bell point with 1.5 sqmmPVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade controlled by one way switch including 1.5 sqmm PVC insulated (FR-LSH) unsheathed copper cable multistranded conductor 1100 volts grade for continuity earth wire connected to common earth dolly drawn through and including concealed PVC Conduit with all accessories including necessary chase cutting complete all as specified and as directed by the Engr-in-Charge. Note: Red coloured cable shall be used for live connection,black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board. |
| 64 | All as per item No 63 here-in-above but for 5 pin 6 Amps switch socket combination on the independent board with 1.5 sqmm cable complete all as specified and directed. |
| 65 | All as per item No 63 here-in-above but for one 5 pin 6/16 Amps switch socket combination on independent board with 2.5 Sqmm PVC insulated unsheathed copper cable multistrand conductor 1100 volts grade and 2.5 sqmmcopper conductor cable as earth continuity conductor complete all as specified and directed. |
| 66 | Supply and fix piano switchmodular type 6 amps 230 volt single pole one way one module complete all as specified and as directed by the Engr-in-Charge. |
| 67 | Supply and fix piano switchmodular type 16 amps 230 volt single pole one way one module complete all as specified and as directed by the Engr-in-Charge. |
| 68 | Supply and fix modular socket multipurpose 2 in 1, 5 pin, 6 amps 230 volt , 2 module complete all as specified and as directed by the Engr-in-Charge. |
| 69 | Supply and fix modular socket multipurpose 2 in 1, 5 pin, 16 amps 230 volt , 2 module complete all as specified and as directed by the Engr-in-Charge. |
| 70 | Supply and fixing piano switchflush type 6 amps 230 volt single pole one way one module complete all as specified and as directed by the Engr-in-Charge. |
| 71 | Supply and fix ceiling rose surface bakelite three terminal65 x 50mm complete all as specified and as directed by the Engr-in-Charge. |
| 72 | Supply and fix Ceiling fans AC single phase 230/ 240 V of size 1200 mm sweep with squirrel cage induction motor complete with three blades and down rods all as specified and directed. |
| 73 | Supply and fix metallic exhaust ventilation fan of sweep 300 mm sweep, 230volt AC complete with louver and all asssesories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing connected with rwin core twisted flexible copper conductor (23/0.0076) of size completeall as specified and directed. Note:- Cost of cutting and making hole for fixing exhaust fan shall be deemed to included in quoated rates |
| 74 | Supply and fix modular fan regulator, step type, 120 W, 230 volt , 2 module complete all as specified and as directed by the Engr-in-Charge. |
| 75 | Supply and fix new generation LED batten fitting20 W , 4 ft length, with extruded aluminium body, PC diffuser and inbuilt driver including necessary electric connection from ceiling rose to light fitting fitted on wall complete all as specified and as directed by the Engr-in-Charge.Make: Century Magik Cat part No BWMP020W2139 or equivalent. make of M/s Surya Roshni Ltd, M/s Wipro, M/s Bajaj ,M/s Century (Magik) Led. |
| 76 | Supply and fixRecess mounting low depth 34 Watt LED 2x2 ftindoor decorative Luminaire with and includingElectronic circuit / driver and LED lamps, pre-wired including necessary electric connection from ceiling rose to light fittingcomplete all as specified and as directed by the Engr-in-Charge.Make:Havells cat part No PLUTONEO2X2PLR34WLED840S or equivalent. make of M/s Surya Roshni Ltd, M/s Wipro, M/s Bajaj ,M/s Century (Magik) Led. |
| 77 | Supply and fix LED street light fitting 45 Watt 230 V AC outdoor type with high pressure diecast aluminum hosing and heat resistant complete with driver and lamp, impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed by the Engr-in-Charge.Make:Havells cat part No ENDURASUNDOWNSL45WLED765PASYBOTG or equivalent. make of M/s Surya Roshni Ltd, M/s Wipro, M/s Bajaj ,M/s Century (Magik) Led. |
| 78 | Supply and fix GI bracket made up of GI pipe 40 mm dia fixed on wall with clamp or PCC foundation on roof for fixing security light complete all as specified and as directed. |
| 79 | Supply and fixMCB DB SPN 4 ways single door recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge. |
| 80 | Supply and fixMCB DB SPN 8 ways with 200 Amps rated bus bar, neutral link, double door recessed with wall surfaces by chase cutting and making good surfaces of wall complete all as specified and as directed by the Engr-in-Charge. |
| 81 | Supply and fix MCB 40 - 63 Amps, SPN, 240 Volt \"C\" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge. |
| 82 | Supply and fixMCB 6 to 32 Amps, single pole, 240 Volt \"c\" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge. |
| 83 | Supply and fixMCB 6 to 32 Amps, SPN, 240 Volt \"c\" series, breaking capacity 10 KA complete all as specified and as directed by the Engr-in-Charge. |
| 84 | S&F white cover plate with frame 12 module complete all as specified and as directed. |
| 85 | S&F white cover plate with frame 4 module complete all as specified and as directed. |
| 86 | S&F white cover plate with frame 3 module complete all as specified and as directed. |
| 87 | S&F modular metal flush box 12 module complete all as specified and directed. |
| 88 | S&F modular metal flush box 4 module complete all as specified and directed. |
| 89 | S&F modular metal flush box 3 module complete all as specified and directed. |
| 90 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 10 Sqmm 2 core as per IS 7098 (Part I)on floor / wallwith suitable size clamp including connection with cable glands, aluminium lugs etc complete all as specified and as directed by the Engr-in-Charge. |
| 91 | Supply and laying under ground XLPE insulated PVC sheathed (Heavy duty) armoured 1100 volts grade aluminium conductor cable of size 6 Sqmm 2 core as per IS 7098 (Part I)on floor / wallwith suitable size clamp including connection with cable glands, aluminium lugs etc complete all as specified and as directed by the Engr-in-Charge. |
| 92 | Materials and labour for earthing as in repair complete with galvanised iron earth plate electrode 600 mm x 600 mm x 6 mm thick, burried directly and preferably vertically in ground, earth pit not less than 2.25 Mtr deep below ground level with top edge of the plate not less than 1.5 m below ground level connetced with galvanised iron wire of dia 4 mmby means of nuts, bolts, check nuts and washers made of galvanised iron or steel earthing lead to be protected by galvanised iron pipe 20 mm bore (medium grade) and other end connected to earthing test point or lightening arrestor or main controlling switch as directed including providing funnel with 20mm bore galvanised iron pipe (light grade), wire mesh, charcoal or coke and common salt in alternate layer of 15cm (compacted thickness) all round the earth electrode, concrete earth pit in PCC (1:3:6) type C-1 (with 20mm graded aggregate), 50mm thick precast RCC (1:2:4) cover slab (re-inforced with 8mm dia TMT bar @ 15 cm C/C bothways and suitable handle made of 10mm dia) including necessary earth work in excavation, returning filling and removal of surplus earth upto a distance not exceeding 50 m etc all as shown on electrical plate No. 3 of MES Schedule Part-I(2009) complete including testing on completion all as specified and as directed by the Engr-in-Charge.Note :- (i) Ifthe desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Testing to be carried out by the contractor in presence of Engr- in- Charge , entered in the earth testing register, prepared and to be maintained by the contractor & submited to Concerned JE E/M.(iii) T&P and testing instrument(Meger) to be provided by the contractor at own cost. |