Defence Government Departments Closing in 0 days TDR #33970342

Construction 70 Kld Stp At Bsf Campus Ambasan Of 154 Bn ( Now 56 Bn Bsf ) Under Shq Bsf Gandhinagar

Issued by Government Departments · Mahesana, Gujarat
Tender Value
40.15 Lakhs
Estimated cost
Bid Submission
27 Sep 2022
0 days left
EMD
80311
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
Mahesana → Gujarat
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Construction 70 Kld Stp At Bsf Campus Ambasan Of 154 Bn ( Now 56 Bn Bsf ) Under Shq Bsf Gandhinagar

BOQ

Name of Work : C/O 70 KLD STP at BSF Campus Ambasan of 154 Bn (now 56 Bn BSF) under SHQ BSF Gandhinagar.
Sl. No. Item Description
1Earth work in excavation by mechanical means (Hydraulic excavator) /manualmeans over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. all kind of soil
2Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 m, including getting out the excavated soil, and then returning the soil as required, inlayers not exceeding 20 cm in depth, including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m : All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia
3filling available excavated earth ( excluding rock ) in trenches, plinth , sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift up to 1.5m
4Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
5Providing and laying in position specified grade of reinforced cementconcrete, excluding the cost of centering, shuttering, finishing andreinforcement - All work up to plinth level and above 1:1½:3 (1 cement : 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size).
6Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but , excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works up to plinth level.
7Providing and laying in position machine batched and machine mixed design mix M-25 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but , excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer-in-charge. (Note :- Cement content considered in this item is @ 330 kg/cum. Excess/less cement used as per design mix is payable/recoverable separately). All works above plinth level up to floor V level.
8Centering and shuttering including strutting, propping etc. and removal of form for all heights :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
9Centering and shuttering including strutting, propping etc. and removal of form for all heights :Suspended floors, roofs, landings, balconies and access platform
10Centering and shuttering including strutting, propping etc. and removal of form for all heights :Lintels, beams, plinth beams, girders, bressumers and cantilevers
11Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
12Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more.
13Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5in foundation and plinth in:Cement mortar 1:6 (1 cement : 6 coarse sand)
14Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in Cement mortar 1:6 (1 cement : 6 coarse sand)
15Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes.
16Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm ( + 0.05 %), total coated thickness with zinc coating 120 gm per sqm as per IS:277 in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
1720 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand)
186 mm cement plaster of mix : 1:3 (1 cement: 3 fine sand)
19Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coats applied @ 1.63 ltr/ 10 sqm. over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm).
20Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work 50 mm nominal outer dia Pipes
21Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer inCharge. External work 100 mm nominal inner dia Pipes
22Providing and fixing G.I. pipes complete with G.I. fittings including trenchingand refilling etc. External work 80 mm dia nominal bore Pipes
23Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) : 80 mm nominal bore .
24Providing, laying and jointing glazed stoneware pipes class SP-1 with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete :150 mm diameter
25Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design: 150 mm diameter S.W pipe
26Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carryguaranteed for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm per coat
27Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carryguaranteed for 10 years against any leakageFor horizontal surface one coat @1.10 kg per sqm.
28Cleaning of manhole of depth 0.45m to 1.50m,sewarage line,gully trap etc by employing sewer man i/c disposalof sludge within 100 mtr. complete as per direction of Engineen-in-Charge.
29Supply, Installation, Testing & Commissioning of vertical FRP vessel with filling of Crystal sand (Peebles, Gravels and Fine Sand in Suitable Proportion) & Carbon media with technical specification (1. Supply of FRP Vessel of dimension 36\"X72\" with 6\" top and bottom opening (1200mmx1800mm) make Pentair or Equivalent 2. Distribution System for Softener Top and bottom 3. Provision of Crystal Sand (Peebles, Gravels and Fine Sand in Suitable proportion ) for Pressure Sand Filter of Dimension 900 mm Dia X 1800 mm Height. 4. Provision of Carbon for Activated Carbon Filter of Dimension 900 mm X 1800 mm height. 5. Multiport valve of 40 NB dia. 6. Piping material along with inner connecting TEE\"s Bends, sockets, Joining solvent solution MOC-CPVC, Make Astrel/Prince/Ashirvad/Equivalent. 7. UPVC Ball valve of 2\" Dia. 8. Labour Charges for plumbing for the filters. 9. Labour Charges (Installation of new vessel along with piping, filling of filter media and plumbing for inter Connecting piping).
30Bar screen Providing and fixing bar screen dimension 1.5 mtr long and 1.0 mtr width ms squar bar suitable for filtering / sperating 12 mm and aboce size solids including painting with epoxy paint
31TUBE SETTLER MEDIASupplying and installing and testing and commisioning of tube settling media of PP/PVC for solid and liquid seperation(Hexavalent Chevoran(Black) inclination with horizontal 750 deg. Make(Invenir/Unitech/Biotech or equivalent as approved by Engineering in charge)
32COURSE BUBBLE DIFFUSERSupplying and installation and testing and commisioning of course bubble difuser circular disc of size 63x600 mm dia make(Invenir/Unitech/Biotech) to provide clog free oxygen for aeration tank
33FAB MEDIA Supplying and installation testing and commissioning of FAB Media black colour UV Stablized(Invenir/Unitech/biotech or equivalent as approved by Engineering in charge) of PP/PVC Self suporting cylinderical shaped structure with fince for enhance dualing space for bacterial growth suitable for 120 KLD STP(1 Cum=1200 Fab Media approximate)
34ELECTRICAL WORK
35Supplying, installing, testing and commissioning of raw sewage transfer 1.6 HP submersible cutter pump model - ETERNA - 1200 CWC, code - T11SY01600801042 del size - 40 mm Make-Kirloskar (Inside Equallisation Tank) with cast iron body and impeller, carbon steel shaft suitable for 3 phase, 415 volt supply with bend,lifting chainarrangement forservice &maintenance, MS metallic stand as perfollowing details: (a)Head-10-12 m (b)Flow – 180LPMc) Del - 40 mm including GST or Equivalent-KSB/Lubby
36Supply, Installation, Testing & Commissioning of Fine Bubble Air Diffusion through Diffusers 3 HPtwine Lobe air cooled compressor Model AGRK-100(V-belt drive) with its standard accessroies for aeration tank and sludge holding tank Suitable for 415 ± 10% volts, 3 phase, 50 cycles A/C supply ,Motor Rating - 3 HP, RPM - 1440 as required MAke-AGS or Equivalent-KSB/Lubby
37Supply,Installation,Testing & Commissioning of Centrifugal, 1 HP monoblock sludge recycle pump make kriloskar model SPOM TP, re cycle pumpofto recycle sludge to Aeration Tank & excess sludge to SDB having discharge rate of minimum suc x del 40 x 40 mm at a head of 10-12 meters with MS base frame duly epoxy painted and grouted suitable for operation on 3phase 400Volt AC including GST or Make-Kirlosakr or Equivalent-KSB/Lubby
38Supply,Installation,Testing & Commissioning of Centrifugal, Mono block, filter feed pump of 3 HP monoblock sludge recycle pump make kirloskar modelhaving discharge rate of minimum suc x del 32 x 25 mm.. at a head of 25-30 meter and 1.5 LPS swith MS base frame duly epoxy painted and grouted suitable for operation on 3phase 400Volt AC supply including GST Make-Kirlosakr or Equivalent-KSB/Lubby
39Supplying, installing, testing and commissioning of sewage 3 Phase 5 HP Eterna Waste Disposer Sump Pump-3700 CW kriloskar model CW 3700 with cast-iron body and impeller, carbon steel shaft suitable for 3 phase, 415 volt supply with following details as required (a)Del size - 65 mm c) Flow Range 300-600 LPM @ 20 Mtr Head d)Solid Handling - 30 mm including GST Make-Kirlosakr or Equivalent-KSB/Lubby
40Supplying, installing, testing and commissioning of loft type Dosing pump of 0.6 HPof suitable size for capacity of 100 Ltr, singlle phase 220 volt capacity as required
41Fabrication of compartmentalised LT Panel made out of 2 mm thick CRCA Sheet Front size 1500 mm x 1500 mm having depth size min 300 mm front side openable hinged door, rubber gaskit on door,dust proof,gland plate i/c cable entry point withpowder coated painting,alongwith fabrication of MS stand made out of 100 mm x 100 x 6 mm angle base frame & leg of 75x75x6mm of 75 cm long including welding,painting,locking arrangement etc as required.
42CONTROL PANEL--Installation,testing & commissioning of cubical outdoor type compartmentalized LT panel, free standing totally enclosed completed dust and vermin proof suitable for 415 V 3 Phase, 50 Hz supply having interconnection with copper wire, painting, ear thing the body & suitable size CC work pedestal with plastering i/c Providing and fixing of following accessories in it etc. as required. with relays, contactors, starters, sequential pump controllers, Aluminum Bus Bars, designation labels as per requirement, continuous earth bar, panel separators, protective screens, cable clamping support system, bottom cable gland plates for incoming and outgoing cable entries,etc. as required.(A) Incoming100 Amps 4 Pole MCCB with with thermal - magnetic Release : based adjustable, over load, short circuit and earth fault protection of breaking capacity 36 KA at 415 Volt AC 50 Hz (ICS = ICU) complete with spreader link phase barrier, extended operating rotary handle confirming to IS /IE 60947-2 etc. complete as reqd. - 1 Nos (b) 0-500Vdigitalvoltmeterwithinbuilt selector switch - 1 set (c)0-100 Amp.Digital Ammeter with inbuilt selector switch and 200/5amps CT- 3 Nos. - 1 set, (d)RYB Indication lamp set with holder, toggle switch and 200 Amp capacity Aluminumbus bar. (e) One no 25 x 5 mm earth bar for the entire width of the panel board . MCCB Make-Havells/C&S/Legrand(B) OUTGOINGDOL starter for 1 Hp- 2 Nos, 2 HP-02 Nos, 3 HP-01 and 5 HP-01Nos and below rating pump/motors i/c Power contactor, Relay, Push button - Start & Stop, Indication lamp; single phase preventor; over load relay etc. for each blower and each pump.
43Supplying & Laying of 3 x 4 sqmm cu cable size flat three core PVC Insulated & PVC Sheathed Industrial Cable for motor pump sets 1100 Volt, conforming to IS 694 PVC insulated and PVC sheathed directly on wall surface/ cable tray etc. as required ( Make -havells/ polycab /KEI/FINOLEX/ANCHOR
44Supplying and installing following size of perforated HotDipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/wall with G.I. suspenders including G.I. bolts & nuts, etc. as required. a) 100 mm width X 50 mm depth X 1.6 mm thicknessA)100 mm width X 50 mm depth X 1.6 mm thickness
45Supplying and installing following size of perforated HotDipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/wall with G.I. suspenders including G.I. bolts & nuts, etc. as required. a) 100 mm width X 50 mm depth X 1.6 mm thicknessA) 150 mm width X 50 mm depth X 1.6 mm thickness
46Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
47Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
48Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/submain wiring/ cable as required.
49Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required. A) 63 mm dia (OD-63 mm & ID-51 mm nominal)
50Supplying and Laying of one number 3.5 x 35 SQ mm PVC sheathed XLPE armoured power Aluminum cable of 1.1 KV gradein the existing DWC HDPE RCC/ HUME/ METAL pipe as required.
51Laying of one numberPVC sheathed XLPE power Aluminum cable of 1.1 KV gradein the existing RCC/ HUME/ METAL pipe as required.
52Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. A)3½ X 35 sq. mm (32mm) (A) 3½ X 35 sq. mm (32mm)
53Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. A)3½ X 35 sq. mm (32mm) (A) 3 X 10 sq. mm (22mm)
54Supplying of Integrated 25 watt solar street light ISL i.e. All in one Fit Forget Solar Smart Street light, which comprises solar panel, Lithium battery, microcontroller based intelligent charge controller cum driver, LED lamp, PIR Motion Sensor in single FRP body with multiple color options, an ideal source for providing outdoor illumination in remote areas and un-electrified sites/regions. with following specifications :-(i)As per MNRE specification for Solar Photovoltaic Lighting Systems & Power Packs - White LED (W-LED) Based Solar Street Lighting Systems, Light Output 25 Lux (ii)Model IV : With Lithium Ferro phosphate battery. Operates from dusk to dawn ( first four hours at full brightness & rest of the time at lower level, with motion sensor) (iii) For Model I: 3 days or minimum 42 operating hours per permissible discharge (iv)Battery Capacity ( 12V-AH @ C/10) 20 AH (v) Warranty For Street Lighting System Including Battery 5 years
55Supplying & making of GI tubular pole of length6 mtr (80 mm dia) mediume class in cement concrete 1:3:6 (1 cement : 3 coarse sand :6 graded stone aggregate 40 mm nominal size)foundation, MS base plate 300 x 300 x 6 mm thickincluding excavation and refilling etc as req as per direction of Engg-in-Charge etc etc as required.Tata/Prkash/Surya/Jindal

AI Tender Summary

OUR REF NO 33970342
AUTHORITY Government Departments
TENDER VALUE 40.15 Lakhs
LAST DATE 27-09-2022
Authority
Authority Name Border Security Force
Work Description Construction 70 Kld Stp At Bsf Campus Ambasan Of 154 Bn ( Now 56 Bn Bsf ) Under Shq Bsf Gandhinagar
Basic Detail
Tender No 14 EE/FTR-GUJ/NIT/2022-23
Bidding Type Tender
Location
City Mahesana
State Gujarat
Key Dates
Publish Date 16 Sep 2022
Submission Date 27 Sep 2022
Open Date 28 Sep 2022
Finance
Tender Value 40.15 Lakhs
Tender Fee Ref. Documents
EMD 80311
Exemption Not Available
Document List
Tendernotice_1.pdf
Tendernotice_2.pdf
Tendernotice_3.pdf
Tendernotice_4.pdf
c7fe12e8-ded4-4b8f-ac7d-728634acf977.html
BOQ_749787.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 16, 2022
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 27, 2022
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 28, 2022

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_1.pdf

pdf

Tendernotice_2.pdf

pdf

Tendernotice_3.pdf

pdf

Tendernotice_4.pdf

html

c7fe12e8-ded4-4b8f-ac7d-728634acf977.html

xls

BOQ_749787.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail